Energy Recovery Ventilators
Greenheck offers a complete line of energy recovery ventilators to reduce your building’s tempering loads in all
climates. From outdoor roof-mounted applications to indoor ceiling-mounted units, Greenheck’s preconditioners
offer the installation flexibility for both new construction and retrofit applications.
Models MiniVent, ERV and ERVe incorporate innovative design features with varying levels of configurable
options and energy wheel performances to provide a quality constructed unit with operational flexibility. The
result is a product that will fit seamlessly into your building to improve your indoor air quality while reducing
energy costs.
Features Benefits
Greenheck’s computer aided product selection (CAPS) software reduces
Industry Leading design time by quickly analyzing system design parameters and providing a list
of units with various energy wheel and fan combinations to minimize cost and
Selection Software
optimize performance. The program outputs fan, electrical, and energy wheel
(CAPS) performance data, as well as configuration-specific 2-D and 3-D drawings for
easy implementation into building schedules and plans.
Product Certifications
Greenheck takes pride in offering a high quality, reliable product. We invest our resources into designing, testing
and manufacturing products to ensure customer satisfaction.
ETL Listed for electrical and overall Energy recovery wheels are certified by the
unit safety. Every unit is tested at AHRI Air-to-Air Energy Recovery Ventilation
the factory before it is shipped to Equipment Certification Program in accordance
the jobsite. with AHRI Standard 1060. Actual performance
in packaged equipment may vary. Certified
ratings are available in the Certified Product
Directory at ahridirectory.org.
2
Energy Recovery
3
Typical Applications
ZONE 1 ZONE 2
Fan conjunction with other
HVAC equipment. Fresh,
outdoor air enters the
RESTROOM
energy recovery unit and is
pretreated before entering
the heating and cooling
RELIEF AIR
equipment.
Whether ducting into
Energy Recovery with Packaged Rooftop Equipment
terminal units, such as
air handlers, or directly
feeding into a rooftop unit,
RESTROOM RTU RTU these preconditioners
provide the ability to
EXHAUST RETURN RETURN
reduce the outdoor air load
AIR AIR AIR of these systems.
Exhaust
Fan
Recovering
OUTDOOR
Packaged
Rooftop Unit
Restroom Exhaust
AIR OUTDOOR
AIR
RETURN (RTU) ASHRAE Standard 62.1
Energy Supply AIR
Wheel Fan dictates that energy
ENERGY RECOVERY recovery devices rated
VENTILATOR (ERV)
for less than 10% cross-
contamination can return
Energy Recovery with Variable Air Volume restroom exhaust through
the device. Any volume of
air transferred through the
RESTROOM RETURN AIR device can be reclassified
as fresh outdoor air. All
EXHAUST
of Greenheck’s energy
AIR recovery units are rated
Exhaust
VAV ZONE 1 well below the 10%
BOX
Fan limit, therefore it is not
only allowable to return
OUTDOOR restroom exhaust, but is
AIR OUTDOOR
AIR
recommended to maximize
Energy Supply
Wheel Fan
AIR HANDLING the benefit.
UNIT ZONE 2
ENERGY RECOVERY
VAV
VENTILATOR (ERV)
BOX
4
Energy Savings
Required Supply Air Minimum Outdoor Air Minimum Exhaust Outdoor Design Indoor Design
(cfm) (cfm) (cfm) (DB/WB) (DB/RH)
6,000 3,000 1,500 95ºF/78ºF 75ºF/50%RH
Traditional System:
An air handling unit and exhaust fan handle the entire load.
85
180
AHU
%
90
80 160
Ai ng
3000 cfm i xi
%
1500 cfm
70
M
r
)
(ºF
%
140
50
re
tu 75
ra
Specific Humidity
pe Outdoor Air
oli s
to Te 70
ng
2
6. lb
Bu 65
Co
100
%
2
et
30
Mixed Air
3000 cfm 6000 cfm W60
80
55
Discharge Return Air
50 60
1500 cfm 45
40 40
35
10%
20
40 50 60 70 80 90 100 110
Dry Bulb Temperature (ºF)
Sea level psychrometric chart. Barometric pressure of 29.921 in. Hg.
85
3000 cfm 180
AHU
%
el
he
3000 cfm
90
80 160
W
%
gy
70
)
er
(ºF
A xing
%
En
ir re 140
50
i
M
t u 75
ra
pe
Specific Humidity
Outdoor Air
li u
15 Coo
.7
tB 100
%
e 65
30
W
3000 cfm 3000 cfm 6000 cfm 60 80
55 Mixed Air
50 Discharge Room Air 60
45
40 40
35
10%
20
40 50 60 70 80 90 100 110
Dry Bulb Temperature (ºF)
Sea level psychrometric chart. Barometric pressure of 29.921 in. Hg.
5
Model ERM
A B C D E F G Approx. Airflow
Motor
Model Weight Range Voltage Hertz Amps Phase
HP
inches (lbs.) (cfm)
ERM-36S/H 34.3 45.4 42 14.8 14.8 14.6 16.6 170 600 - 2,300 200-230/460 50/60 1.2 1 1/6
ERM-52S/H 50.4 61.6 58.4 22.4 22.4 14.6 16.6 280 2,300 - 4,500 200-230/460 50/60 2.8 1 1/2
ERM-58H 54 64.6 62.7 24.1 24.1 16.5 18.7 440 4,500 - 6,000 200-230/460 60 1.3-1.2/0.6 3 1/4
ERM-64H 59.8 70.4 68.2 26.9 26.9 19.1 21.1 700 6,000 - 7,500 200-230/460 60 1.3-1.2/0.6 3 1/4
ERM-74H 69.9 80.2 78.5 31.5 31.5 20.1 22.1 870 7,500 - 10,000 200-230/460 60 1.3-1.2/0.6 3 1/4
Typical Installation
Models ERM-36 and 52 are Room Air
Exhaust
easily installed either vertically
or horizontally. Models ERM-58,
64, and 74 must be installed Outdoor Air
Intake
in the vertical position due to
size and weight. The diagram
illustrates a typical horizontal ERM-2
ERM-3
installation of multiple modules ERM-1 Room Air
Intake
where airflow exceeds single
Direction of cassette removal
wheel capacities.
Outdoor Air
Supply
6
Model MiniVent
Models MiniVent-450 and 750 are energy recovery
ventilators for commercial and institutional applications
that require 150 to 850 cfm of ventilation air. The compact
design provides an economical solution for individual
spaces, such as school classrooms and small offices. The
MiniVent is designed for indoor installations and may be
floor-mounted or ceiling-hung. A removable panel enables
easy access to filters and enthalpy wheel. Unit comes
standard with backdraft damper and optional Vari-Green®
EC motors available.
A B C Approx.
Airflow Range
Model Weight
inches (cfm)
(lbs.)
450 37.6 26.4 19.9 150 150 - 500
750 43.2 33 23.8 250 450 - 850 Available Intake/Discharge Positions
Option Bottom Top Side End
OA Intake X X
SA Discharge X
B
RA Intake X X
A EA Discharge X
Typical Installation
The illustration shows a MiniVent in
a typical ceiling-hung installation.
Outdoor air is drawn through a
model GRS roof mounted gravity Outdoor Air
intake hood and preconditioned
by the enthalpy wheel. Outdoor
air is then supplied either to an air
handler or directly to the space.
Energy is recovered from stale
return air before it is exhausted
through a model WC wall cap. Pre-conditioned
Supply Air
Exhaust Air
Return Air
7
Model ERV
A B C Approx. Airflow
Model Weight Range
inches (lbs.) (cfm)
ERV-10 46.1 27 33.7 300 500 - 1,000
ERV-20 62 34.1 51 720 1,000 - 2,200
ERV-45 67 44.4 67.1 1100 2,200 - 4,300
ERV-55 74.9 66 69.2 1470 4,300 - 5,800
All weights include dampers and filters.
EXHAUST FILTERS
ENERGY
WHEEL
WHEEL CASSETTE
C
C
SUPPLY FILTERS
SUPPLY
FILTERS
A
A
S
ER
FILT
P PLY
SU
TE
ET B
A SS RS
ELC ILT
E
E TF
WH
WHEEL CASSETTE
US
SUPPLY FILTERS
HA
EX
B
8
Model ERV
Models ERV-90 and 120 are designed for both indoor Available Intake/Discharge Positions
and outdoor applications requiring 5,000 to 12,000 cfm of
Option Bottom Top Side End
ventilation air. The dual-wheel design provides exceptional
OA Intake X
effectiveness while retaining its ease of maintenance
characteristics. SA Discharge X X
RA Intake X
EA Discharge X X
ERV-90, 120
ELECTRICAL BOX
WH EX
EE HA
LC US
AS TF
SE ILT
TT ER
E S
SU C
PP
OUTDOOR LY
F ILT
WEATHERHOOD ER
S
WH
EE
LC
AS
SE
TT
E
EXHAUST
WEATHERHOOD E
D A
SUPPLY
FILTERS
OUTDOOR
WEATHERHOOD
ENERGY ENERGY
WHEEL WHEEL
9
Model ERVe
A B C D E Approx.
Airflow Range
Model Weight
inches (cfm)
(lbs.)
ERVe-20 65.9 52.6 45.1 18 20.7 950 1,000 - 2,200
ERVe-35 68.1 62.6 53.2 22.1 17.8 1,270 2,200 - 3,400
ERVe-45 72.1 68.9 60.2 22 19.1 1,500 3,400 - 4,500
ERVe-55 83 75.4 70.2 21.7 23.5 1,960 4,500 - 6,000
All weights include weatherhoods, dampers, and filters.
EXHAUST FILTERS
WHEEL CASSETTE
C
SUPPLY FILTERS
OUTDOOR
WEATHERHOOD
D A
OUTDOOR
Model Number Code WEATHERHOOD
ERVe - 35 - 30H
SUPPLY FILTERS
WHEEL CASSETTE
B
Model Parent Wheel
Thickness
15 (1.5 in.)
Nominal Airflow 30 (3 in.)
20 (2,000 cfm)
35 (3,500 cfm) Airflow Rate
45 (4,500 cfm) H - High
55 (6,000 cfm) L - Low
10
Optional Control Sequences
and Unit Control Options
Optional Control Sequences
Energy Wheel Economizer Control Fan Speed Control
When the outdoor air conditions are favorable, the To accommodate the system requirements, the fan
controller will allow the economizer operation. The unit speed can be adjusted to:
will adjust the energy wheel operation to: • Multi-speed - Allows the fan to operate at three
• Stop wheel - Energy wheel rotation will stop preset speeds determined by a set of input
and outdoor air can be brought into the building contacts
unconditioned • Modulating - Vary the fan speed from 50-100%
• Modulate wheel - Energy wheel speed will based on an analog input signal
modulate to maintain a leaving wheel temperature
of 55ºF Demand Control Ventilation
Varies the amount of outdoor air based on occupancy.
Energy Wheel Frost Control Available options are:
Prevents frost buildup on the energy wheel in climates • CO2 Sensor - Mounted in the unit, return air duct
that have cold outdoor winter temperatures (typically or in the space, this sensor determines occupancy
less than -10ºF) and/or moist indoor conditions such and modulates the fan speed accordingly or it
as a gym locker room. Available options are: cycles the unit on and off to provide the appropriate
• Timed exhaust - Cycles supply blower to melt amount of outdoor air.
frost with warm return air • Time clock - A remote panel can be equipped with
• Electric preheat - Preheats outdoor air to avoid a 7-day programmable time clock to turn the unit
frosting off based on a schedule.
• Modulate wheel - Reduces the wheel speed to
increase the time exposed in the warm return air Frost Control Strategy Recommendations
Recommended
Winter Outside Winter Indoor
Frost Control
Air Design Air Design
Strategy
≥10ºF ≤50%RH None
≥-5ºF Timed
≤35%RH
<10ºF Exhaust
≥10ºF ≥50%RH
≥-5ºF Electric
≥35%RH
<10ºF Preheat
<-5ºF Any RH
Model RVE
This rooftop ventilation unit combines
the benefits of total energy recovery
with supplemental heating and cooling
for indoor or outdoor applications
designed to process high percentages
of outdoor air. Airflow capacities range
from 800 to 12,000 cfm.
Model ERCH
This dedicated outdoor air unit combines
the benefits of total energy recovery with
supplemental heating and cooling for
applications designed to supply 100%
outdoor air. Airflow capacities range
from 1,000 to 10,000 cfm.
Model APEX
This unit combines energy recovery
along with several heating and cooling
options. This large capacity dedicated
outdoor air unit is designed for 100%
outside airflow and capacities that
range from 10,000 to 20,000 cfm.
Enjoy Greenheck’s extraordinary service, before, during and after the sale.
Greenheck offers added value to our wide selection of top performing, energy-efficient
products by providing several unique Greenheck service programs.
• Our Quick Delivery Program ensures shipment of our in-stock products within 24 hours
of placing your order. Our Quick Build made-to-order products can be produced in
1-3-5-10-15 or 25-day production cycles, depending upon their complexity.
• Greenheck’s free Computer Aided Product Selection program (CAPS), rated by many
as the best in the industry, helps you conveniently and efficiently select the right
products for the challenge at hand.
• Greenheck has been Green for a long time! Our energy-saving products and ongoing
corporate commitment to sustainability can help you qualify for LEED credits.
• Our 3D service allows you to download, at no charge, easy-to-use AutoDesk™ Revit™
3D drawings for many of our ventilation products.
Find out more about these special Greenheck services at greenheck.com
Our Commitment
As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications
without notice.
Specific Greenheck product warranties are located on greenheck.com within the product
area tabs and in the Library under Warranties.
Prepared to Support
Green Building Efforts
Greenheck P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com