1 S oftware E ditions
LITE Standard Professional Enterprise FREE**
INTEGRATED ACCESS CONTROL CS-AC-LITE-USB5 CS-AC-STD-USB5 CS-AC-PRO-USB5* CS-AC-ENT-USB5* Starter Pack
Sites 1 64 64 64 1
any access control challenge Dial Up connection Yes Yes Yes Yes Yes
Cards 512 2,048 per site 8,196 per site 16,384 per site 512
(131,072 max.) (524,544 max.) (1,048,576 max.)
Doors 16 128 per site 512 per site 2048 per site 2
(8,192 max.) (32,768 max.) (131,072 max.)
64 per site
Yes
System Overview
Elevator Cabs - (4,096 max.) (8,192 max.) (32,768 max.)
2
Asset Management Guard Tour Feature Biometric Integration
Floors per cab - 64 64 64 64
Why buy something that you Live interactive guard tour allows Centaur is a powerful solution for
already have? Keep track of your check point validation using card areas requiring enhanced security
Floor groups - 128 per site 128 per site 128 per site 128
assets and save time and money. readers, input points (Motion by authenticating fingerprints. (8,192 max.) (8,192 max.) (8,192 max.)
Find quickly who is in possession sensors, key switches, or push Capturing, managing and
of your assets. A report can be buttons) or data collectors. Includes transferring biometric data is now DVR Module - Yes Yes Yes Yes
generated and sent automatically live alarms for time violations and effortless with world-renowned
via email. intuitive exception reports. fingerprint readers such as CDVI’s
DGID/W/US, L-1 (model 4G), Sagem Visitor Management - Yes Yes Yes Yes
and more.
Parking Management - Yes Yes Yes Yes
CT-V900-A
Also includes an output of
16 VAC (75 VA) that can power up to 3 CP - Thin card for printing (ISO)
2-door expansion modules CA-A470-A
+ + -
+
2 batteries
- + (12V, 7AH)
- - Connect earth terminal to connected in series
a certified earth ground for 24V backup CPE - Standard clamshell card
Power - Fire alarm
Supply + contact for
Lock1 & Lock2
S erver to C ontroller C ommunication Controller N etwork E- bus N etwork Capacity & Modules
Jumper & Dipswitch S ettings 1 Transformer
16 VAC, 40VA
START POINT 50/60Hz Class 2
of the RS-485 controller network.
(Furthest modules can be up to 1220m and
(4000ft) from start point) 1 battery (12V, 7AH) per
SERVER CA-A480-A & CA-A470-A
RS-232
CONVERTER 7.6m (25ft) max.
SETTINGS Elevator Controller 2-Door Expansion Module
EOL= ON
CA-A480-A CA-A470-A
POSITION
CA-A360-A
RECEIVE
TRANSMIT
Bias High/Low Jumpers At the START POINT and the END POINT of the RS-485
+12V
GND
GND
GND
RX
TX
A+
B-
Optional First controller A+= Low controller network, the devices’ EOL jumpers= ON.
Networked B-= Low
of a site All devices‘ in between EOL= OFF
Workstation (CT-V900-A)
CONTROLLER #1 SETTINGS Note: If you do not use a converter, the first CT-V900-A
CT-V900-A #1 controller will be the START POINT.
EOL= OFF
Bias High/Low Jumpers At the START POINT of the RS-485 controller network,
A+= High the device HIGH/LOW Bias jumpers is set to A+ = LOW
B-= High and B- = LOW. All other modules’ HIGH/LOW Bias jumpers
ON
OFF
1 2 3 4 5 6 7 8
START POINT
of the RS-485 E-bus network At the START POINT and the END POINT of the
(Furthest module can be up to installation, the modules’ EOL jumpers = ON. LCD Display Relay Expansion Module USB/RS232 to RS-485
CT-V900-A All modules in between EOL = OFF
1220m (4000ft) from start point) CONTROLLER #2 SETTINGS CK-TRAK-L CA-A460-P Converter
CT-V900-A #2
At the START POINT of the network, the modules’ EOL= OFF (Max. 8 per CT-V900-A) (Max. 2 per CA-A360-USBRS
EOL= ON HIGH/LOW Bias jumpers are set to A+ = LOW and B- = ADDRESSABLE
Dipswitch Setting
2-Door Controller
9.6K/19.2K
DEF/RUN
ADD 16
ADD 32
END POINT
ADD 1
ADD 2
ADD 4
ADD 8
CA-A480-A CA-A480-A
CONTROLLER E-BUS
NETWORK JUMPERS NETWORK JUMPERS
E-BUS E-BUS
AC AC
CA-A470-A CA-A470-A
AC AC
A+ A
BAT+ A+ A
BAT+
LOW HIGH LOW HIGH
B- BAT- B- BAT-
B B
GND LOW HIGH +12V GND LOW HIGH +12V
TAMPER EOL 350mA/700mA +12V TAMPER EOL 350mA/700mA +12V
TAMPER FC OVERIDE
GND TAMPER FC OVERIDE
GND
AC
BATT REVERSED
GND AC
BATT REVERSED
GND
COM1 FC COM1 FC
RL16
RL16
12V 12V
RL1
RL1
DRM MODULE
BATT BATT
NC1 NC1
COM2 NC16 COM2 NC16
RL15
RL2
RL2
CONTROLLER #3 SETTINGS
NC2 COM16 NC2 COM16
CA-A470-A CA-A470-A
COM3 Elevator Controller NC15 COM3 Elevator Controller NC15
2-Door Expansion Module AC 2-Door Expansion Module AC
NO3
CA - A480 - P NO15 NO3
CA - A480 - P NO15
AC AC
RL14
RL14
COM15 COM15
RL3
RL3
STATUS
ON
D1NC AC OK D1NC AC OK
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
ADDRESS 2 V+ V+
NO4 FREE ACCESS NO14 NO4 FREE ACCESS ADDRESS 2 NO14 AUX OK
V+
AUX OK
V+
COMM FAILURE ADDRESS 4 COMM FAILURE ADDRESS 4 COM COM
ADDRESS 8 ADDRESS 8 JP120 COMM JP120 COMM
NC4 BATT TROUBLE RLY COMMS
COM14 NC4 BATT TROUBLE RLY COMMS
COM14 D1NO
LOCK#2
350mA/700mA CHECK BATT V- D1NO
LOCK#2
350mA/700mA CHECK BATT V-
RL13
RL13
RL4
RL4
RLY OFF/ON NC13 RLY OFF/ON NC13 BATT TRBL V- BATT TRBL V-
D2NC D2NC
ON
ON
1 2 3 4 5 6 7 8
OUT5 OUT5
CT-V900-A #3
SWITCH SWITCH
PWR OFF/ON NO13 PWR OFF/ON NO13 COM
SW1 ADD 1 OUT6
COM
SW1 ADD 1 OUT6
RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12 RL5 RL6 RL7 RL8 RL9 RL10 RL11 RL12 D2NO D2NO
COM13 COM13 SW2 ADD 2 SW2 ADD 2
SW3 L1Energize SW3 L1Energize
Z1 Z1
COM
SW4 L2Energize
2 COM
SW4 L2Energize
2
4 4
SW5 BACKUP1 SW5 BACKUP1
Z2 SW6 BACKUP2 LOW HIGH
A+ Z2 SW6 BACKUP2 LOW HIGH
A+
SW7 PULSE 5&6 B- SW7 PULSE 5&6 B-
Z3 SW8 N/D A+ B- Z3 SW8 N/D A+ B-
COM GND COM GND
5 5
EOL= ON
READER#2 READER#1 READER#2 READER#1
Z4 BACKUP TMP Z4 BACKUP TMP
3 3
DATA DATA DATA DATA
2 1 TMP 2 1 TMP
EOL EOL
EOL
0 0 NO CARD 0 0 NO CARD
COM10
COM12
COM10
COM12
COM11
COM11
COM5
COM6
COM7
COM8
COM9
COM5
COM6
COM7
COM8
COM9
NO10
NO12
NO10
NO12
NC10
NC12
NC10
NC12
NO11
NO11
0 1 2 CARDS 0 1 2 CARDS
NC11
NC11
R2/KPD
R2/KPC
R2/KPD
R2/KPC
R1/KPD
R1/KPC
R1/KPD
R1/KPC
R2/KPB
R2/KPB
R1/KPB
R1/KPB
R2/KPA
R2/KPA
R1/KPA
R1/KPA
R2/+5V
R2/+5V
R1/+5V
R1/+5V
OUT4
OUT3
OUT4
OUT3
NO5
NO6
NO7
NO8
NO9
NO5
NO6
NO7
NO8
NO9
OUT2
OUT1
OUT2
OUT1
NC6
NC7
NC8
NC9
NC6
NC7
NC8
NC9
NC5
NC5
R2/D1
R2/D0
R2/D1
R2/D0
R1/D1
R1/D0
R1/D1
R1/D0
R2/0V
R2/0V
TX RX TX RX
R1/0V
R1/0V
+12V
+12V
+12V
SP
SP
SP
ON OFF
Destination TCP/IP Module RS-485 Network Hub
9.6K/19.2K
DEF/RUN
ON OFF
CA-A482-P
1 2 3 4 5 6 7 8
DRM ENABLED
DRM ENABLED
PWR OFF/ON
PWR OFF/ON
RLY COMMS
RLY OFF/ON
RLY OFF/ON
ADDRESS 1
ADDRESS 2
ADDRESS 4
ADDRESS 8
ADDRESS 1
ADDRESS 2
ADDRESS 4
ADDRESS 8
PULSE 5&6
PULSE 5&6
L1 Energize
L2 Energize
L1 Energize
L2 Energize
BACKUP1
BACKUP2
BACKUP1
BACKUP2
ADD 1
ADD 2
N/D
N/D
END POINT
the CA-A480-A, elevator controller
ON ON ON ON
All the specifications on this document (photos, drawing, features and dimensions) could be changed without prior notice.