Sie sind auf Seite 1von 44

 

 
USER’S MANUAL 
FOR  
X‐RAY BAGGAGE SCANNER 
 
 

 
 
 
Revision  Date  Description Initials
0  2017‐01‐02  New template LR
‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐
‐‐‐  ‐‐‐  ‐‐‐  ‐‐‐
   
Index 
 
Chapter 1 – INTRODUCTION ......................................................................................................................... 4 
1.1. Safety Warning Signs.......................................................................................................................... 4 
1.2. Safety Precautions ............................................................................................................................. 5 
Chapter 2 – EQUIPMENT DESCRIPTION ........................................................................................................ 6 
2.1. Scanning Body .................................................................................................................................... 6 
2.2. Operating Keyboard ........................................................................................................................... 8 
Chapter 3 – X‐RAY MACHINE BASIC OPERATION ........................................................................................ 11 
3.1. X‐Ray Machine Inspection ................................................................................................................ 11 
3.2. Turning the X‐Ray Machine On ........................................................................................................ 11 
3.3. Operating Interface .......................................................................................................................... 12 
3.4. Object Inspection ............................................................................................................................. 13 
3.5. Power off .......................................................................................................................................... 14 
Chapter 4 – IMAGE DISPLAY AND READING ............................................................................................... 15 
4.1. Status Information Area ................................................................................................................... 15 
4.2. Image Processing Functions Area .................................................................................................... 17 
4.3. Operation Functions Area ................................................................................................................ 23 
4.4. Menu and Image Navigation Area ................................................................................................... 23 
Chapter 5 – MENU SETTINGS ...................................................................................................................... 24 
5.1. Image Management ......................................................................................................................... 25 
5.1.1 Sorting Images................................................................................................................................ 25 
5.1.2. Image Selection ............................................................................................................................. 26 
5.1.3. Exporting Images ........................................................................................................................... 26 
5.1.4. Opening an Image ......................................................................................................................... 26 
5.1.5. Printing an Image .......................................................................................................................... 26 
5.1.6. Training Mode ............................................................................................................................... 27 
5.2. Operator Management .................................................................................................................... 27 
5.2.1. Operator ........................................................................................................................................ 28 
5.2.2. Group ............................................................................................................................................ 28 
5.2.3. Miscellaneous ............................................................................................................................... 29 
5.2.4. Record ........................................................................................................................................... 30 
5.3. TIP (Dangerous Goods Detection) .................................................................................................... 31 
5.3.1. Image Library ................................................................................................................................ 31 

Page 2 of 44 
 
5.3.2. Rule ............................................................................................................................................... 32 
5.3.3. Record ........................................................................................................................................... 33 
5.4. Diagnose ........................................................................................................................................... 34 
5.4.1. Detector ........................................................................................................................................ 34 
5.4.2. X‐Ray Generator ............................................................................................................................ 35 
5.4.3. Infrared Sensor .............................................................................................................................. 36 
5.4.4. Control Keyboard .......................................................................................................................... 36 
5.5. Settings ............................................................................................................................................. 37 
5.5.1. Key ................................................................................................................................................. 38 
5.5.2. Display ........................................................................................................................................... 38 
5.5.3. Scan ............................................................................................................................................... 39 
5.5.4. Assist Check ................................................................................................................................... 40 
5.5.4. Counter ......................................................................................................................................... 40 
5.5.5. System ........................................................................................................................................... 41 
5.6. About ................................................................................................................................................ 41 
Chapter 6 – CARE AND MAINTENANCE ...................................................................................................... 42 
Chapter 7 – TERMINOLOGY ........................................................................................................................ 43 
Chapter 8 – TROUBLESHOOTING AND SUPPORT ........................................................................................ 44 
 
 
   

Page 3 of 44 
 
Chapter 1 – INTRODUCTION 
 
Dual‐energy X‐Ray security inspection equipment is a new security inspection equipment 
which makes use of the penetrating power of X‐Ray to implement the rapid inspection of the 
packing  baggage  and  goods.  The  equipment  is  equipped  with  the  advanced  X‐Ray  image 
detection system and combines the advantages of the efficient semiconductor detector, digital 
image processing technology and computer image display to provide users with an efficient and 
reliable high‐quality image processing system with the service function. 
The  equipment  can  store  any  number  of  high‐definition  images,  and  has  the  reliable 
automatic  alarm  function  for  the  dangerous  goods  and  drugs,  operator  training  function, 
dangerous  goods  insertion  function  (TIP),  network  extending  and  interconnection  function, 
automatic error check and maintenance function. 
 
1.1. Safety Warning Signs 
 
Sign 
Pictogram  Description  Location 
Number 
Film safety and radiation 
1  Tunnel access 
danger signs 
 
Instruction on how to 
2  place objects for  Tunnel access 
  scanning (flat not raised) 
Instruction to raise the 
Side panels bottom, both 
3  unit using a forklift 
sides 
(heavy item) 
 

4  High voltage warning sign Outside power connection 

5  Ground terminal sign  Internal equipment 
 

6  X‐Ray source  X‐Ray source or sensor box 

 
Moving parts warning  Both sides of the conveyor 

sign  belt 
 

Page 4 of 44 
 
8  Do not insert your hand  Front access tunnel 
 
9  EMERGENCY  Emergency stop sign  Front and rear tunnel access 
10  POWER  Power light  Front and rear tunnel access 
11  X‐RAY  X‐Ray in use light  Front and rear tunnel access 
12  ALARM  Alarm light  Front and rear tunnel access 
 
1.2. Safety Precautions 
 
Do  not  operate  the  X‐Ray  machine  without  receiving  training  related  to  radiation 
protection according to the local state and federal laws and regulations. 
All operators must receive necessary training on how to operate the equipment.  
Report the installation and operation of the X‐Ray machine to local authorities. It is the 
client’s responsibility to acquire approval for system operation and to get operation approvals 
from local authorities. 
Check the radiation protection conditions of X‐Ray as recommended by manufacturer. 
If the X‐Ray machine is not in operation for an extended time, allow the X‐Ray generator 
to  preheat  according  to  the  factory  settings.  This  will  guarantee  the  service  life  of  the  X‐Ray 
generator. 
Do  not  store  the  equipment  in  an  environment  that  contains  conductive  dust  or 
chemicals. 
Connect  the  unit  to  a  professionally  installed  power  source,  according  to  the  local 
regulations. 
For maintenance and repairs, contact a factory approved service company. 
If any of the components (cables, belt, indicator lights, lead curtain, etc.) are damaged, 
turn off the machine and contact a factory approved service company. 
Do not open side panels. 
When on, do not leave the machine unattended. 
After the machine is powered on, do not insert any living body parts (hand, legs) or live 
animals  through  the  machine’s  tunnel.  This  can  result  in  body  radiation  and  life  threatening 
situations. 
When the conveyor belt is in use, the operator shall pay attention to objects placement, 
to prevent them from blocking the access to the tunnel or falling from the conveyor belt. 
Do  not  allow  liquids  from  spilling  over  the  conveyor  belt  or  inside  the  tunnel.  If  such 
situation occurs, turn the machine off and clean it immediately. 
When the equipment is in operation, do not cover the vents of the access panel to ensure 
that the heat dissipation inside the equipment internal is in good condition. 
For the daily cleaning maintenance of the equipment, cut off the power. 
   

Page 5 of 44 
 
Chapter 2 – EQUIPMENT DESCRIPTION 
 
The X‐Ray machine has two major components. The first one is the scanning body that 
contains  the  conveyor  belt,  X‐Ray,  processing  unit  and  power.  The  second  one  is  the  review 
console that has the review monitor and the operation keyboard. 
 
2.1. Scanning Body 
 
See image below for details on the scanning body and the monitoring console. Depending 
on the model, some of the features may or may not be available: 
 

 
   

Page 6 of 44 
 
 
Emergency Stop Button  The emergency stop buttons are installed at top of the inlet and 
outlet of the tunnel and on the operating keyboard (see section 2.2. 
Operating Keyboard). When the button is pressed, the conveyor 
belt and the x‐ray emission will stop immediately. 
Note: the emergency stop button provided is latching, which
means, that in order to return to normal operation, the button
needs to be rotated according to the arrow on the button, about
30°. 
Power Light  The power lights are installed at top of the inlet and outlet of the 
(Green)  tunnel. They indicate the scanning body is turned on. 
X‐Ray Light  The X‐Ray lights are located at top of the inlet and outlet of the 
(Red)  tunnel, and on the operating keyboard (see section 2.2. Operating 
Keyboard). This light indicates that the scanning body is emitting X‐
Ray (actively scanning objects). 
Alarm Light  The alarm lights are located at top of the inlet and outlet of the 
(Yellow)  tunnel. Alarms can be triggered when alarm function is enabled 
(scanned objects contain suspected or impenetrable goods). The 
display screen will box out the area and the light will go on at the 
same time. 
Lead Curtain  The X‐Rays lead curtain block x‐ray from leaking outside the tunnel. 
Note: If any part of the lead curtain is damaged or missing, turn off 
the machine and call service support. 
Conveyor Belt  The conveyor belt transfers the objects through the X‐Ray tunnel. 
Note: If the conveyor belt or any other component is damaged, 
turn off the machine and call service support. 
Review Console  The monitor and the operating keyboard are located inside the 
review console. 
PC Mouse  Depending on the unit model, this item is optional or standard. The 
user can zoom in on the screen image by rolling the wheel on the 
mouse. 
 
   

Page 7 of 44 
 
2.2. Operating Keyboard 
 
The keyboard is used by the operator to turn on/off the conveyor belt, to view, replay 
and to store images. For layout and button information, see image and table below: 
 
    7       1        2       3              4              5                6       11 

 
          8           9            10 
 
The user has to insert the right key and to turn the system 
on. The absence of the key will not allow the user to turn 
on the machine when pressing the Start Button. 
Rotate the switch clockwise to the “ON” position to 
1  Key Switch 
enable the next step (See Start Button below). 
 
Rotate the switch counterclockwise to the “OFF” 
positions. The workstation and the X‐Ray machine will 
turn off. 
When the Key Switch is in ON position, pressing the start 
2  Start Button  button will power the X‐Ray machine and will boot the 
  processing unit and turn on control lights. 
Once the system is on, these light will indicate: 
‐ Power ON; 
3  Status Lights  ‐ Communication between processing unit and 
  control keyboard; 
‐ System status; 

4  X‐Ray Light  This is on when an object is scanned (X‐Rays are emitted). 
 
Page 8 of 44 
 
When the button is pressed, the conveyor belt and the x‐
ray emission will stop immediately. 
Emergency  Note: The emergency stop button is latching, which

Button  means, that in order to return to normal operation,
 
rotated it about 30°, according to the arrow on the
button.
6  Image Processing Buttons 
This button allows the user to switch between color and 
Color/BW Image 
B/W images. 
 
This button allows the user to enable or disable the 
Organics Sieving 
organics sieving image function 
 
This button allows the user to enable or disable the 
Inorganic Sieving 
inorganic sieving image function 
 
Invert  This button allows the user to invert image colors. 
 
Super 
This button allows the user to enhance image quality. 
Enhancement 
 
This button allows the user to increase the X‐Ray 
High Penetrating 
penetrating power for objects that require more 
Power 
  attention. 
When an image is in full screen mode, impenetrable areas 
Sign Alarm  will be highlighted in purple red by pressing this button. 
  Pressing the button again will restore the image. 
Z789 Suspicious 
This button allows the user to enhance certain suspicious 
Organics 
  organics. 
Enhancement 
When in full screen mode, pressing this button allows the 
Optimal Screen  user to restore a zoomed in image to 1:1 ratio and to 
  center it. 

Function Switch  NOT ENABLED 
 
These buttons allow the user to zoom in (from x1 to x64) 
Zoom In/Out  or zoom out. For the rate of magnification, see the 
bottom of the screed. 
Variable  This button allows the user to adjust the image variable 
Absorption Rate  absorption rate. 
   

Page 9 of 44 
 
7  Function Keys 
When not in energy savings mode, the conveyor belt runs 
continuously. When the button is pressed, the conveyor 
belt will stop after 15 seconds if there are no objects 
Energy‐saving 
detected on the conveyor belt. 
 
NOTE: This button functions only for units that have 
energy‐savings sensor module installed. 

Menu  This button allows the user to enter the system menu. 
 
Exit  This button allows the user to exit the system menu. 
 
This button allows the user to access the image 
Image 
management dialog box. Press the Menu button and then 
Management 
the Image Management button. 
For setting the function buttons, see section 4.3. Default 
configuration is: 
Custom 
8  F1 – Super Enhancement 
Functions 
F2 – Local Enhancement 
F3 – Image Invert 
9  Conveyor Control 
This button allows the user to set the conveyor belt to 
Forward 
  move forward  
Stop  This button allows the user to stop the conveyor belt 
 
This button allows the user to set the conveyor belt to 
Back 
  move backward   
This area allows the user to move the mouse cursor and 
10  Mouse Pad 
  use the left and right mouse buttons. 
When an image is in 1:1 scale, left and right arrows allow 
Direction  the user to call back historical images. 
11 
Navigation  When magnifying an image, the arrows allow the 
operator to move the image up, down, left and right. 
 
   

Page 10 of 44 
 
Chapter 3 – X‐RAY MACHINE BASIC OPERATION 
 
Do not operate the machine without reading these operating instructions first.

3.1. X‐Ray Machine Inspection 
 
Before  turning  the  machine  on,  confirm  power  requirements  (110Vac  or  220Vac)  and 
inspect whether the power cable is properly connected. Make sure the equipment is properly 
grounded.  If  the  machine  is  equipped  with  a  network  interface,  check  the  network  cable  is 
connected to the machine. See image below: 
  

 
Check all emergency buttons on both the scanning unit and the operating keyboard. If 
any of them is pressed, rotate it clockwise to reset it. Note: If any of the cables are damaged and 
the  insulation  is  scratched,  or  the  emergency  buttons  are  not  resetting,  do  not  turn  the 
machine on and contact service support. 
  Check the lead curtains at both tunnel entry and exit sides. The curtains should not have 
obvious gaps or damage. Note: If gaps or damages are noticed do not turn the machine on, and 
contact service support. 
  Check  the  conveyor  belt  for  any  cracks  or  damages.  Note:  If  the  belt  shows  signs  of 
cracks, damages or it is misaligned, do not turn the machine on, and contact service support. 
  Check  the  inside  of  the  tunnel  for  left  behind  objects.  If  any,  remove  and  notify  the 
supervisor. 
 
3.2. Turning the X‐Ray Machine On 
 
Insert the key into the key switch of the control keyboard and rotate it clockwise 90° to 
the “ON” position. Press and hold the power button for about 1 second until the power light 
turns on. Wait for the processing unit to boot. 
   

Page 11 of 44 
 
3.3. Operating Interface 
 
The system will automatically login as the default user. Note: If the system administrator 
disabled the automatic login function, then use the provided user name and password to login. 
  The user can control the X‐Ray machine using the buttons from the operation keyboard 
or using the soft buttons displayed on the monitor, by using the keypad mouse (or the regular 
mouse if the monitoring console is equipped with one). 
Note: Going forward, in this manual, the first button to be shown will be the soft button 
(on  the  screen).  The  second  button  to  be  displayed  is  the  hard  button  on  the  operating 
keyboard. For example, on the image below, the operator can acknowledge the command by 

pressing the soft button or the hard button:   or  . 
  After login, the software will display a “Clear the Channel” warning sign. The operator can 
move the conveyor belt using the left/right soft buttons or the keypad left/right buttons: 
 

/  soft buttons 

 operating keypad buttons 
 

Use the stop buttons once the tunnel is cleared:   or  . 

Once everything is clear, press the OK buttons: or . 
If the machine is not in use for more than 24 hours, the X‐Ray generator needs to pre‐
heat when the machine is turned on. The image below will be displayed when entering the main 
interface. Wait for 1 to 20 minutes for the X‐Ray generator to pre‐heat. 
 

 
 
The preheat mode helps to extend the lifetime of the X‐Ray generator. For an estimated 
waiting period, see the table below: 
 
If the machine is not on for 1 to 3 days  Preheat time: 3 minutes 
If the machine is not on for 3 to 30 days  Preheat time: 6 minutes 
If the machine is not on for 30 to 90 days  Preheat time: 12 minutes 
If the machine is not on for more than 90 days Preheat time: up to 60 minutes 

Page 12 of 44 
 
Once preheat is complete, the system main interface will be displayed; see image below: 
 

 
 
3.4. Object Inspection 
 
Place  the  object  on  the  conveyor  belt,  at  the  tunnel  entry  (follow  placement  warning 
sign). 
Notes: 
‐ Place  light,  thin,  dirty  and  damaged  objects  in  appropriate  plastic  container  for 
inspection. 
‐ Do  not  extend  hands  or  any  other  body  parts  behind  the  lead  curtain,  inside  the 
tunnel. 
‐ Do not scan live animals. 
‐ If objects accumulate at the exit of the tunnel, press the emergency stop button and 
clear the belt. 

Click the move buttons ( /  or  ) to run the conveyor belt forward 


and backward, as necessary. When the objects are scanned, the X‐Ray lights will turn on (on both 
the unit and the keyboard) and an image will display on the screen: 
 

Page 13 of 44 
 
 
 
Note: In default mode the operator can scan object only when the conveyor belt moves 

forward.  If  Bi‐directional  Scanning  function  is  enabled,  the  operator  can  use  /   or 

 to scan objects when the conveyor belt moves backward. 
Once the object image appears on the screen, the operator can click on the function keys 
to better identify and judge the objects. 

When the object arrives at the tunnel exit, press the conveyor belt stop button ( ) 
and remove the object. The operator can proceed to the next object inspection. 
 
3.5. Power off 
 
Check conveyor belt and tunnel for any left behind object. If any, remove it and notify the 
supervisor. 

Press the stop button (  or  ) and rotate the key switch counterclockwise to 


OFF position. The system will power off automatically. 
Notes: 
‐ Do not disconnect the power until all lights are off. 
‐ Wait for 60 seconds before starting the machine again. 
Remove the key from the key switch and store it according to the rules. 
   

Page 14 of 44 
 
Chapter 4 – IMAGE DISPLAY AND READING 
 
See image below for the monitor view of the operating interface: 
 
                  Image Display Area 

 
Status    Image    Operation   Menu and 
Information    Processing    Functions    Image 
    Functions        Navigation 
 
4.1. Status Information Area 
 

 
 
There are three groups of users: sys (system 
Current user  administrator), mt (maintenance) and usr (general user). 
  group  For the initial startup, the system will login as “usr”. 
Change the user using the menu options. 
Magnification  This area displays the current magnification rate, which 
  rate  can vary from x1 to x64. 

Page 15 of 44 
 
The equipment can display a number of six status 
reports: waiting, ready, preparing, scanning, paused and 
fault. 
Ready – system started normally and conveyor belt is not 
running. 
Preparing – object is on the conveyor belt and is moving 
Equipment  towards the tunnel. X‐Ray light turns on. 
  status  Scanning – object moves in the scanning area, inside the 
tunnel. 
Paused – the object is in scanning area, but the operator 
reverses or stops the conveyor belt. 
Waiting – the object clears the scanning area. 
Fault – typically when the emergency button is triggered, 
or another fault appears with the system. 
Uni‐DIR – scan objects when conveyor belt moves 
Scanning  forward only. 
  mode  Bi‐DIR – scan object when conveyor belt moves either 
forward or backward. 
This area displays the number of objects scanned by the 
Counter 
  operator 
When “Assist Check / Display Identification tags” is set to 
“Hide”, no markers will be displayed. If it is set to  
Automatic  “Show”, then the following markers are displayed: 
  sensor switch  Red marker – objects difficult to penetrate 
Yellow marker – suspected explosives 
Green marker – suspected drugs 
TIP function  Displays the status of the TIP function, either ON or OFF 
 
Forced scan  Display the status of the forced scan, either ON or OFF 
System time  Display system time 
Display current system status. Certain codes are available 
for easy fault identification: 
[100] Failure to communicate with the master controller. 
[101] Power switch of master controller triggered. 
System status
[102] Emergency button triggered. 
[103] Micro‐switch for L‐type box triggered. 
[104] Micro‐switch for side cover plate triggered. 
[105] Acquisition system fault. 
 
   

Page 16 of 44 
 
4.2. Image Processing Functions Area 
 
Images shown on the display monitor can be manipulated using the operating keyboard 
or the soft buttons shown below: 

 
 
The software displays the image with four types of colors according to a category: 
orange for the organic matter, blue for inorganic matter, green for mixed and black (or red) for 
objects with uncertain properties (or hard to penetrate). See below various options 
 
BW 
Color Image / Black and White Image  Select BW to remove colors from the image. 
 

 
Select LE when an object is hidden behind 
LE  Local Enhancement  another one or it has uncertain material 
properties. 

 
   

Page 17 of 44 
 
HP  Enhancement of High Penetrating 
This selection modifies the image contrast.  
Power 
 

Enhancement of Low Penetrating  This selection improves the contrast of the 
LP 
Power  darker areas (low penetration) 

GE  This selection displays objects hidden behind 
Super Enhancement 
thick objects. 
 

   

Page 18 of 44 
 
This selection turns grey all organic material, 
OS  Organics Exclusion  allowing the operator to see the inorganic 
material (guns, knives, cans, etc.). 

MS  This selection turns grey all inorganic material, 
Inorganic Exclusion  allowing the operator to see the organic 
  material (drugs, explosives, etc.). 

 
RS  This selection allows the operator to highlight 
Negative 
less X‐Ray absorbent objects, like metal wire. 
 

   

Page 19 of 44 
 
This selection allows the operator to brighten 
BR   Brightening 
the image 

This selection allows the operator to darken the 
DK   Darkening 
image. 

This selection allows the operator to darken the 
GS  Grey Level Scan 
brighter areas and to brighten the darker areas. 

 
Use the operating keyboard to process images, as detailed below: 
 
These buttons allow the operator to 
enlarge an image up to x64 its original 
size. This action can also be accomplished 
Image Magnification 
  by using the mouse wheel. Select the 
middle button to bring the image to its 
original size. 

Page 20 of 44 
 
When an image is magnified, the arrows 
allow the operator to move the image up, 
  down, left and right. 

 
This selection allows the operator better 
identify objects. The combination of PC and HP 
function is suitable for the view of high‐density 
PC  Pseudo‐Color Processing 
objects. The combination of the PC and RS 
function is suitable for the view of the thin 
objects (like wires) 

This button allows the operator to highlight 
certain objects based on their atomic number. 
Suspicious Organics Enhancement 
7 – water, plastic explosives 
  Z7 / Z8 / Z9 
8 – impure drugs or explosives 
9 – pure drugs 

   

Page 21 of 44 
 
This command allows the system to 
automatically highlight the areas that contain 
Alarm Sign Box of Suspicious 
suspicious items (red, yellow and green), and to 
  Organics 
turn the alarm light on for the security 
personnel. 

This button allows the operator to sharpen the 
EE  Edge Enhancement 
original image. 

 
   

Page 22 of 44 
 
 
4.3. Operation Functions Area 
 
This area contains shortcut keys (F1 – Super Enhancement, F2 – Local Enhancement, F3 – 
Negative), conveyor belt commands (forward, stop and back) and image commands (previous 
and next 
 

 
 
The function buttons can be customized. Default configuration is: 
F1 – Super Enhancement 
  F2 – Local Enhancement 
F3 – Image Invert 

These buttons allow the operator to use the mouse to move or stop 
the conveyor belt. The same commands can be done using the 
keyboard buttons:   

These buttons allow the operator to navigate through images 
(previous and next). 

 
4.4. Menu and Image Navigation Area 
 
This  area  allows  the  user  to  enter  the  settings  menu,  to  calibrate  the  machine  and  to 
preview images. 
 

 
 

Page 23 of 44 
 
Click on the Menu soft button (or the keypad button  ). There are three access levels: 
system administrator (sys), maintenance (mt) and operations (usr).  
Click   on the Calibrate soft button  to calibrate the equipment performance. After the 
operation is complete, the results are indicated on the result status bar of the information area. 

 refers to the normal scan state or the corresponding setting state. Click “Menu” 

button  to  enter  the  menu  interface,  and  press  the    button  again  to  switch  between 

,  and .  When  entering  the  training  mode,    will  be 


displayed on this location. 
The image navigation are allows the operator to see the object from the main image in 
the object line context. 
 

 
 
Chapter 5 – MENU SETTINGS 
In  order  to  access  the  menu  setting,  press  on  the    on  the  control  keyboard. 
Depending on the access level, the sub‐menu has different options, see image below: 
 

 
          System Administrator            Maintenance      Operations 

Page 24 of 44 
 
To access the appropriate menu, logoff and then log in using the approved username and 
password. 
 
5.1. Image Management 
 
This option allows the user to enter the image management menu, see image below: 
 
 

 
 
5.1.1 Sorting Images 
 
On the bottom menu, select the third button: “Category 3”. This will enable the 
operator to sort images by category and time. 
 

 
 
Category  ‐ Automatically saved ‐ image files recorded and saved in the scanning process 
‐ Sample – images built‐in the equipment 
Time  This option includes multiple time choices: “Current session”, “Today”, 
“Yesterday”, “The day before yesterday” and “All” 
 

Page 25 of 44 
 
5.1.2. Image Selection 
 
Select the corresponding images in the automatically saved list by clicking the "Select 
All" button, "Deselect" button or a single click of the mouse applied on the image file. When an 
image is selected, as shown in the image below, the following information becomes available: 
scanning date and time, user and picture number. 

 
 
5.1.3. Exporting Images 
 
Insert a memory device (such as a USB stick) and choose the images to be exported. Click 
the "Export" button and select desired format types for exporting the image (XF, PNG, BMP, JPEG, 
TIFF, GIF): 
 

 
 
5.1.4. Opening an Image 
 
Select the image and click“0pen” button to preview and to process the image. 
 
5.1.5. Printing an Image 
 
If the equipment is equipped with a printer, then you can click “Print” button to print 
the selected image(s) 
   

Page 26 of 44 
 
5.1.6. Training Mode 
 
Click “Train” button and a pop up screen will confirm the system is in training mode: 
 

 
 

Press   and   on the keyboard, the system will enter the operator’s training 


mode. End the training mode by selecting “Menu” and then “Finish Training”: 
 

 
 
5.2. Operator Management 
 
This option allows the system administrator to manage users and groups. As seen below, 
there are four tabs: Operator, Group Miscellaneous and Record: 
 

 
 

Page 27 of 44 
 
5.2.1. Operator 
 
This option allows the system administrator to add, edit and remove users. Fill in user 
name, assign a group and then click “Reset PWD”. Allow the user to input password. 
This selection also allows the administrator o Edit or Delete any users: 
 

   
 
5.2.2. Group 
 
The group list has three permission groups: administrator, maintenance and operation; 
the privilege list shows all the permissions of this group: 
 

 
 
Click "Add" button to add a new group and to assign privileges (system settings, image 
management, TIP, system diagnosis, operator management), and then click "OK" button. 
 

Page 28 of 44 
 
 
 
Click "Edit" button to modify the name, description and permission of the group; and 
click the "Delete" button to delete a group: 
 

 
 
5.2.3. Miscellaneous 
 
Set up “Automatically Log in the System” and “0perator Automatically Log in”. The default 
settings are “Enabled” and “usr”, 
 

Page 29 of 44 
 
5.2.4. Record 
 
This  option  allows  the  administrator  to  see  and  export  logs  containing  operator  user 
name, login and log‐out time spent and counter. 
 

 
 
Click  the  "Export"  button  to  select  the  exporting  location  (local  or  external  memory 
device), and also click "Create Directory" button and enter the name of the new directory (to 
save the log): 
 

 
   

Page 30 of 44 
 
5.3. TIP (Dangerous Goods Detection) 
 
The administrator can automatically insert images of dangerous objects into the scanner 
memory, which will trigger and alarm once a matching object is detected during a regular scan. 
The TIP menu has three tabs: Image Library, Rule and Record: 
 

 
 
5.3.1. Image Library 
 
The  image  library  lists  the  image  folders  of  dangerous  goods  to  be  inserted  "knife", 
"knife2"  and  so  on.  Open  the  pull‐down  menu  of  the  corresponding  file  and  choose  the 
corresponding files to preview the image content. 
 
Import  allows the user to import typical images 
Delete  allows the user to delete images 
Name  allows the user to name the images 
Ratio  allows the user to change the image ration zise 
 
   

Page 31 of 44 
 
5.3.2. Rule 
 
This menu allows the administrator to enable rules for images 
 

 
 
Enable  It refers to the enabled state of TIP, and you can choose "yes/no". If you 
select yes", the TIP is ON and at the same time, the information area on 
the application software interface displays: "TIP: ON"; if you select "no", 
the TIP is OFF and at the same time, the information area on the 
application software interface also displays: "TIP: OFF". In addition only 
in the condition of "TIP; ON", the settings below are valid. 
Insertion interval  It refers to that how many parcels one dangerous product is inserted. 
The range is the value of multiples of 5: 5‐100, and the insertion is 
random.  
Floating Range  It refers to the floating range of the insertion position for the TIP plc. and 
can be set to the value of multiples of 5 by 0% ~100%. 
Time to  It refers to the time from the appearance to disappearance of the TIP 
Recognize when  images, if in case of insert the TIP image while the scanning images are 
Keep Moving  moving (i.e., you can recognize the TIP image in this period of time). 
During this period, if the tester or the user presses the functional 
shortcut "Recognize TIP" (a functional shortcut can be set to "Identify 
TIP" on the system setting, as shown in Section6.6), then the interface 
will pop up the prompt: “Has Recognize TIPxxx”; if no action is applied 
to" Recognize TIP" shortcut in this period, the interface will pop up the 
prompt:” Fail to Recognize TIPxxx”, as shown in the settings above. 
When TIP images are inserted, you can press "Recognize TIP" functional 
shortcut within 4 seconds, then the interface will pop up the prompt: 
“Has Recognize TIPxxx”; if no action is applied to" Recognize TIP" 
shortcut within4 seconds, the interface will pop up the prompt: “Fail to 
Recognize TIPxxx”. 4 seconds later, the TIP pic. will disappear 
automatically, and it can reappear only in the training mode 

Page 32 of 44 
 
Time to  It refers to the time from the appearance to disappearance of the TIP pic, 
Recognize when  while the scanning images are static. The principle and process are as the 
Keep Still  same with moving state. 
 
5.3.3. Record 
 
This option allows the administrator to see and export logs. 
 

 
 
Click  the  "Export"  button  to  select  the  exporting  location  (local  or  external  memory 
device), and also click "Create Directory" button and enter the name of the new directory (to 
save the log): 
 

 
   

Page 33 of 44 
 
5.4. Diagnose 
 
This option allows the administrator to diagnose the equipment performance. 
 

 
 
5.4.1. Detector 
 
Detector diagnosis module can display the gray level data curve of the sensor array and 
you  can  press  “Start  Emit”  and  “Stop  Emit”  to  observe  the  gray  level  of  the  curve  to  check 
whether the detector is in good condition and whether the position of the detector board is in 
the appropriate position. 
”Start Emit" button – the X‐ray begins to emit and the curve rises;  
"Stop Emit" button – the X‐ray stops emitting, the curve falls back. 
"Forward", "Stop" and "Backward" button to test the "Forward", "Stop" and Reverse" 
operations of the conveyor belt. 
"Close" button – exit from the equipment diagnosis menu. 
 

 
 
 
Page 34 of 44 
 
Curve Judgement Criterion: 
‐ Different devices are equipped with different number of the detection plates and the 
number of sensing points differs. 
‐ The  gray  level  of  the  curve  should  be  between  25,000  and  55,000  and  the  whole 
curve presents an arc with a hollow center. 
 
5.4.2. X‐Ray Generator 
 
The diagnosis module can show whether the voltage and current are normal under the 
condition of the normal emission of rays to make a preliminary judgment of X‐ray generator: 
 

 
 
”Start Emit" button – the X‐ray begins to emit and the system displays the normal voltage 
and current. 
"Stop Emit" button – the X‐ray stops emitting. The specific voltage and current settings 
vary with the equipment model. 
"Forward",  "Stop"  and  "Backward"  button  to  test  the  "Forward",  "Stop"  and  Reverse" 
operations of the conveyor belt. 
"Close" button – exit from the equipment diagnosis menu. 
   

Page 35 of 44 
 
5.4.3. Infrared Sensor 
 
The "infrared sensor” diagnosis module is used to diagnose whether two pairs of infrared 
sensors are activated at entrances and exits. 
Test Method 1: Place an opaque object at the entrance to keep off the ray of infrared 
sensors, then Port A will output a high‐level square wave; the longer the blocking time is, the 
wider the square wave will be. This shows the Port A operation is normal. Test Port B in the same 
way. 
Test Method 2: When you place an object on the conveyor and click the button, then Port 
A will output a high‐level square wave.  This shows the Port A operation is normal. Port B will 
output a high‐level square wave, which shows like the image below: 
 

 
 
5.4.4. Control Keyboard 
 
Use this option to test if the keys on the control keyboard are operational. Only technical 
personnel shall use this mode. 
‐ The  "Power"  button,  the  "right  button"  of  mouse  and  the  mouse  navigation  area 
cannot be tested in the diagnosis module. 
‐ When you click the buttons on the multifunction keyboard, the corresponding button 
on the software interface will be on. During the test, you should repeatedly test each 
button for 6 ‐ 10 times and observe whether the key on the keyboard is pressed or up 
normally and the corresponding button is on timely and smoothly. 
‐ When  you  click  "Exit"  button,  the  system  exits  from  the  diagnosis  menu  of  the 
keyboard. 
 

Page 36 of 44 
 
 
 
5.5. Settings 
 
This menu allows the system administrator to set various options (“F” keys, display, scan 
assist check, counter and system). 
 

 
   

Page 37 of 44 
 
5.5.1. Key 
 
This option allows the system administrator to set a command for the three “F” keys on 
the  control  keyboard.  By  default,  the  commands  are  F1  –  Super  Enhancement,  F2  –  Local 
Enhancement and F3 – Negative. From the drop down menu, additional command options are: 
 
Original Image  Inorganic Exclusion  Assistant recognize 
Edge Enhancement  Z789  Recognize TIP 
Super Enhancement  Negative  Log Off 
High Penetration  Grey Scanning  Power Save 
Low Penetration  Var‐Absorbency Minus  Reset Automatically 
Brightening  Var‐Absorbency Plus  Image Management 
Darkening  Colorizing/Black and White  Operator Management 
Local Enhancement  Organic/Inorganic Exclusion TIP Management 
Black and White  HighPen/LowPen  System Settings 
Pseudocolor  Brighten/Darken  System Diagnose 
Colorizing  Force Scanning  About 
Organic Exclusion  Calibrate System   
 
 Select Yes/No for “Exchange Belt Direction Control Key”. 
 
5.5.2. Display 
 
Use the “Display” function to set the mirror images (horizontally or vertically), to set the 
maximum magnification rate of the images or magnification reset once a new image is displayed 
on the screen. See image below: 
 

 
   

Page 38 of 44 
 
5.5.3. Scan 
 
See image below for the “Scan” menu: 
 

 
 
Bi-directional Scanning  This option enables the X‐Ray machine to scan objects when the 
conveyor belt is moving forward and back. Select “No” to scan only 
when the conveyor belt is moving forward 
Scanning Direction  This option determines the scanning direction of the X‐Ray machine 
(default is “Forward”). This option is only available when the 
machine is set to uni‐directional. 
Forces a Scan  This option is used to scan ultra‐thin objects. Default is set to “No”. 
Energy‐Saving Mode  This option is used to stop the conveyor belt 15 seconds after no 
objects are placed on it. Default is set to “No” 
Calibrates Automatically  Enable or disable automatic calibration when a user log’s into the 
When Logged in to the  machine. 
System 
 
   

Page 39 of 44 
 
5.5.4. Assist Check 
 
The  system  can  automatically  detect  certain  objects  that  can  be  hard  to  penetrate, 
dangerous or illegal. This option allows the user to enable or disable this function, and to highlight 
any such object. 
 

 
 
5.5.4. Counter 
 
This option allows the system administrator to reset the temporary counter upon user 
login  and  to  display  the  count  information  on  the  software  interface.  Note:  Total  Counter 
information cannot be reset. 
 

 
   

Page 40 of 44 
 
5.5.5. System 
 
This option allows the system administrator to set the system date/time, tube current 
and gain value. 
 

 
 
Date and time synchronize automatically with the industrial PC. 
Select “Senior 1” button to enter the advanced menu. Technicians should only perform 
these operations. This option enables the technician to change X‐Ray tube current and the gain 
value. 
 
5.6. About 
 
This menu allows the operator to view machine scan information such software version, 
scanner type and serial number, scanning timer, working timer, emit timer and remaining and 
total capacity. 
 

 
 
Click the “S.N.1” button to activate the serial number of the machine. 
   

Page 41 of 44 
 
Chapter 6 – CARE AND MAINTENANCE 
 
Follow the instructions below in order to maintain safe operation and to extend operating 
life  of  the  machine.  NOTE:  before  operating  any  maintenance  turn  off  and  disconnect  the 
machine from the power supply. 
 
1. Clean up the surface of the equipment on a regular basis in order to guarantee the 
normal operation of equipment. Remove dust or any other kind of dirt using a clean 
moist towel. 
2. If the injection port of the photoelectric sensor is covered or blocked, the equipment 
will emit x‐ray and scan immediately. If "Force a Scan" function is disabled, then the 
photoelectric sensor may be covered or blocked. Please turn off the equipment and 
remove the key from the operation keyboard. The photoelectric sensor is located on 
the inner wall of the tunnel inside the lead curtain. Check whether the photoelectric 
sensor is covered, which may affect the accuracy of the photoelectric sensor signal. 
Gently wipe the surface of the photoelectric sensor with the moist cotton ball to clean 
the sensor surface. 
3. Disconnect power to the monitor. Wipe the LCD screen gently with a soft, dry cloth. 
If any marks remain, moisten the cloth with LCD cleaner, and then gently stroke the 
cloth across the display in one direction, moving from the top of the display to the 
bottom. 
4. During a prolonged scanning process, the conveyor belt of the equipment may deviate 
from  the  center,  which  will  require  a  belt  adjustment.  Contact  professional 
maintenance personnel to adjust the conveyor belt. 
5. Inspect and dust clean the lead curtain. If the gap is too large or the curtains fall or 
are  damaged,  contact  the  professional  maintenance  personnel.  NOTE:  use  gloves 
when adjusting or replacing the lead curtains. 
6. Inspect the light indicators and make sure they function as described in this manual. 
If any damages are found, contact professional maintenance personnel. 
7. The Emergency Stop buttons on the X‐Ray machine and the operation keyboard are 
the key safety devices, so if one of them or both are loose or its shells are damaged, 
stop  the  equipment  immediately,  and  contact  the  professional  maintenance 
personnel  to  maintain  or  replace  the  corresponding  Emergency  Stop  button.  After 
maintenance, press this Emergency Stop button. At this moment, the motor inside 
the system will stop running; the X‐ray generator will stop emitting X‐ray. A pop‐up 
message will show on display stating the “Emergency Stop button is pressed down” 
which show that the switch can work normally. 
 
 
   

Page 42 of 44 
 
Chapter 7 – TERMINOLOGY 
 
Equipment:  Micro‐dose X‐ray security inspection equipment based on computer 
platform for energy resolution. 
Line Resolution:  Equipment’s ability to distinguish a single solid copper line. The line 
resolution is generally expressed in nominal diameter of the line (mm) or 
the corresponding wire size (AWG). 
Penetration Resolution:  The ability of the equipment to distinguish the single solid copper line 
under the condition of the aluminum alloy step with the specified 
thickness. The penetration resolution is expressed in the nominal diameter 
of the line (mm) or the corresponding wire size (AWG). 
Penetrating Power:  The ability of the equipment to penetrate an object to be inspected and is 
generally expressed in the thickness of the steel plate (mm). 
Space Resolution:  The ability of the equipment to distinguish a metal wire. It is expressed in 
the nominal diameter of the line (mm). 
Equivalent Atomic  In interaction of X‐ray and matter, the equivalent atomic number is the 
Number  characteristic parameter used to calculate the attenuation, absorption and 
scattering ability regard with to X‐ray. For the elementary substance, the 
position number in the periodic table, namely the electron number of an 
atom for the substance, it is the atomic number; for the compound or 
mixture, it is obtained by calculation or experiment. 
Organics  Substance with the equivalent atomic numberless than 10. 
Inorganics  Substance with the equivalent atomic number more than18. 
Single Inspection Dose  X‐ray dose absorbed by the goods to be inspected in the process of one 
inspection in Gy (1Gy=1J/kg). 
Ray Leaking Dose Rate  Ionizing radiation intensity per unit time of the X‐ray which penetrates the 
radiation shield and leaks out of the equipment in uGy/h. 
Micro‐dose X‐ray Security  X‐ray security inspection system with the single inspection dose less than5 
Inspection System  uGy. 
Start Button of Secondary  It refers to the switch component that should be confirmed twice to power 
Electric Power Supply  on the equipment, and is generally applied for the radiation equipment. 
Preheating Tube  It refers to the process of X‐ray tube's voltage being increased gradually in 
the boot and automatic start process of the equipment, and its purpose is 
generally to protect the service life of the ray tube. 
Scroll  It is used to display the image from left to right of the screen or from right 
to left. 
Operator Sensor  Sensor used to detect the operator on‐the‐job state. If the system is 
equipped with such component, then when the operator is close to it, the 
equipment can normally; when the operator is away from it, the 
equipment will automatically shut off the power supplies of the X‐ray 
generator and the conveyor. 
Emergency Stop  It is used in an emergency and will cut off the power supplies of the X‐ray 
button  generator and the conveyor at once. 
X‐ray Detector  A sensor that can detect (measure) X‐ray and convert the X‐ray intensity 
into a processed electrical signal. 
Test Object(Box)  Test object used to test and evaluate the performance indications of X‐ray 
image. 
Test Card  Test object used to test and evaluate an index of X‐ray image. 

Page 43 of 44 
 
Organics Resolution  It refers to the ability of the equipment to distinguish organics and is 
expressed in the thickness of discriminable organic step. 
Inorganics Resolution  It refers to the ability of the equipment to distinguish inorganics and is 
expressed in the thickness of discriminable steel step. 
Impenetrable Area  The objects’ area that cannot be identified by the equipment. The strength 
that the X‐ray penetrates the objects and reaches the detector is almost 
zero. 
Uncertain Material  It refers to the area where the X‐ray can penetrate but the detector cannot 
Area  identify the material property of the goods to be inspected. 
Pass Rate  It refers to the quantity of goods in length of 1 meter inspected by the 
equipment within one hour. 
 
Chapter 8 – TROUBLESHOOTING AND SUPPORT 
 
For Troubleshooting and Support, please contact Aventura Technologies Inc.: 
Tel:    +1.631.300.4000  
Fax:    +1.631.434.7000  
Email:    techsupport@aventurasecurity.com 
Skype:    aventurasupport 
Web‐site:  http://www.aventurasecurity.com 

Page 44 of 44 
 

Das könnte Ihnen auch gefallen