Beruflich Dokumente
Kultur Dokumente
NEW
Costs saving
CING
WHEN REPLA
filter media!
In filtration classes G2 – F5
according to EN 779
• Stable frame made • Easy installation and • Low initial pressure loss
of zinc-coated steel, small replacement of filter medium • Filter thermal resistance
building depth of filter • Operating costs saving up to 100 ºC
• Large filtration area • Long service life due to • Easy replacement of filter
• Replaceable filter medium progressive design of filter medium
medium
Frame filters with replaceable filter media KS PR NEW
Technical data
Filter type KS PR... 50/G2 50/G3 50/G4 50/F5 100/G2 100/G3 100/G4 100/F5 100/G2 150/G3 150/G4 150/F5
Filtration class according to EN 779 – G2 G3 G4 F5 G2 G3 G4 F5 G2 G3 G4 F5
Nominal air flow rate in relation
2,800 2,800 2,800 1,300 3,400 3,400 2,800 1,700 3,400 3,400 2,800 2,500
to 592 x 592 mm filter
Separation efficiency (Am) according
% 65 - 80 80 - 90 >90 – 65 - 80 80 - 90 >90 – 65 - 80 80 - 90 >90 –
to EN 779
Efficiency (Em) according to EN 779 % – – – 40 - 60 – – – 40 - 60 – – – 40 - 60
Initial pressure loss at nominal load Pa 40 60 95 45 55 80 105 90 50 85 120 160
Recommended final pressure loss Pa 250 250 250 250 250 250 250 250 250 250 250 250
Maximum thermal resistance o
C 90 100 100 100 100 100 100 100 100 100 100 100
Field of application
The frame filters KS PR with replaceable filter inserted between the separators is secured by edge and push it between the separators,
media are used for trapping coarse and fine two wire pressure springs at the air inlet. resulting in pleats. Finally, insert the medium
dust in air-conditioning and ventilation units. at the other end of the frame and secure it
Metal separators through which media are The metal separators are surface finished. with pressure springs.
inserted are placed in the robust zinc-coated Remove the fouled media inserted between The filters are especially used for the air
frame. A wire grid preventing the media the metal separators after easy removing conditioning and ventilation of factory
release and increasing an operating safety pressure springs. Then, insert a new cut-to-size buildings, office facilities and assembly rooms,
of the filter is at the air outlet. The medium element of the filter media under the frame health centres, airport terminal buildings, etc.
W
Wire network
Filter medium
2
Frame filters with replaceable filter media KS PR NEW
KS PR NEW 48 pressure loss diagram
3
Overview of frame filters
Frame filters – KS Z (G2 – G3) Frame filters – KS PR (G3 – F5) Frame filters – KS PL (G2 – F5)
Frame filters – KS MMP 96/4, 96/5 Frame filters – KS MMP 96/6, 96/7
Frame filters – KS PL-5 (G2)
(G4 – F5) (F6 – F7)
© KS Klima-Service a.s.
KS Klima-Service a.s. Tel.: 00420 318 541 111
Na Trávníkách 1588 Fax: 00420 318 541 112
CZ - 263 01 Dobříš E-mail: info@ksklimaservice.cz
www.ksklimaservice.cz