PUMPSTATION INPUT DATA sewage system
sewage data
GL= 3.15 M HOUSES 540 NO
INLET PIPE= 0.7 M #CAP/HOUSE NOW 10 CAPITA
INV PIPE= 0.04 M Qav. /Cap 0.46 M3/DAY
NO. PIPE 1 NO year 25
n= 0.011 DESIGN PERIOD n= 0.011 YEARS
pipe length 22 m ∆POP% 0.03
min. slope = 0.0012 PF 0.9
storm data
SCREEN CHAMBER Atotal= HA
LENGTH= 2 m i= mm/hr
WIDTH= 2 m streat area = m2
BASE OFFSET UNDER INLET PIPE = 0.25 m green area= m2
DISTANCE BETWEEN WETWELL= 3 m buildings area= m2
BASE THIKNES= 0.3 m C=
WALL THIKNESS= 0.3 m
ROOF THIKNESS= 0.25 m
HEAL WIDTH= 0.8 m
WT= 2 m
NOTES:
esign Calculations For Alqibla Project ZONE ZONE
M1
PUMPSTATION HYDRAULIC CALCULATION sewage system
DISCHARGE CALCULATIONS:
POPULATION:
p= 11,306.40 capita @ 2043
Qavg= 4,680.85 m3/day
Qpeak= 14,042.55 m3/day
Qinft.= 1,404.25 m3/day
Qtotal peak= 15,446.80 m3/day
0.8
/D
Polynomial (d/D)
xisd
Qparial=Qtotal peak= 0.18 m3/sec 0.500
A
0.3
Qpartial/Qfull= 0.709 0.400
d/D= 0.615 0.300 0.2
Vactu./Vfull= 3.7958690643 0.200
Vactu.= 2.49 m/sec 0.100 0.1
Pipe INV at up= 0.04 m 0.000
Pipe INV at down= 0.0136 m 0
0 0.2 0.4 0.6 0.8 1 1.2
DEPTH OF WATER IN PIPE= 0.4308487506 m
Axis q/Q
NOTES: ELEVATION
* OF PIPE INV. IN MANHOLE
ELEVATION
** OF PIPE INV. IN WETWELL
esign Calculations For Alqibla Project ZONE ZONE
M1
PUMPSTATION HYDRAULIC CALCULATION sewage system
DESIGN OF COARSE SCREEN
Qavg = 4680.85 m3/day
Quantity of Screenings = Qavg x 30 / 1000000
= 0.1404 m3/day v/V
Provide storage for 7 days
Quantity of Screenings 7 x =Quantity of Screenings per day 0.8
= 0.983 m3 0.7
Number of Storage Units = 1
f(x) =0.68.5400170782x^5 - 20.8540633992x^4 + 18.4069175549x^3 - 6.6666012798x^2 + 1.1170400749x - 0.0033015862
Quantity per Unit = 0.983 m3
Dimension of screen basket in front of inlet pipe 0.5
L = 1.50 m
W = 1.00 m 0.4
H = 0.50 m 0.3
Volume = 0.750 m3 0.983 m3 MUST DAILY CLEENING
Dimension of screenings trough 0.2
L = 1.50 m 0.1
W = 1.00 m
D = 0.50 m 0
0 0.2 0.4 0.6 0.8 1 1.2
Volume = 0.750 m3 > 0.983 m3 error
Screen Design
Bar Size Bs = 10 mm
Clear Opening Co = 25 mm
NOTES:
Efficiency Coefficient Ef = Clear Opening Vmax= 1 m/ses
Clear Opening + Bar size Vmin= 0.3 m/sec
Sewer Pumpstation Design Calculations For Alqibla Project ZONE ZONE
M1
PUMPSTATION HYDRAULIC CALCULATION sewage system
= 0.71
Clear area through each scree AQpeak= Qpeak /Vmax
A= 0.097 M2 0
DEPTH OF WATERIN SCREEN= 0.25 M 0
WIDTH OF SCREEN= 0.39 M v/V 0
Number of Openings= 16 OPEN
NO OF BAR= 15 BAR X 1 CM THIK
USE
L = 1.50 m
W = 1.00 m
H = 0.50 m
Volume = 0.750 m3
q/Q 0 0.10 0.20 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1
v/V 0 0.10 0.20 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.05
NOTES: d/D 0 0.05 0.07 0.09 0.11 0.15 0.2 0.24 0.32 0.4 0.5 0.7
Sewer Pumpstation Design Calculations For Alqibla Project M1
PUMPSTATION HYDRAULIC CALCULATION
WEIGHT OF TANK
ROOF ELEV= 3.65 m
length of pipe= 22 m
Sump Elv.= -2.2364 m
WALL HIGH= 5.6364 m
Volume of walls= 13.52736 m
volume of base= 2.52 m
volume of roof= 0.6 m
weight of tank= 41.6184 T
SUBMERCY VOLUME= 24.10928 m3
up ward force = 236.270944 kn
= 23.6270944 T
EXTENSION VOLUME= 2.496 m3
weigh of extention= 6.24 T
DOWN WARD FORCE= 35.3784 T NO FLOATING
Sewer Pumpstation Design Calculations For Alqibla Project M1
PUMPSTATION HYDRAULIC CALCULATION
WETWELL INPUT DATA
Length of tank= 3 m
Width of tank= 3 m Fitting type Quantity K factor Total K factor
GL= 3.15 m 90º Elbow 4 0.5 2
dist.sump from INP= 2.25 m Tee 1 1.7 1.7
WALL THIKNESS= 0.3 m Reducer 0 0.7 0
BASE THIKNES= 0.3 m Gate Valve 1 0.2 0.2
ROOF THIKNESS= 0.25 m Check valve 1 2 2
pump high 1 m
pump width= 0.8 m TOTAL K= 5.9
MIN WATER high= 1.000 m
PUMPING VELOCITY= 0.25 m3/SEC
force main pipe materials 140
force main pipe LENGTH= 500 m
OUTLET STRUCTURE SUMP 2 M
# CHECK VALVE= 1 NO
#GATE VALVE= 1 NO
# BEND= 4 NO
1
#TEE = 1 NO
# PUMPS= 2 NO
HEAL WIDTH= 0.8 M
Sewer Pumpstation Design Calculations For Alqibla Project
PUMPSTATION HYDRAULIC CALCULATION
V= 2.53 M/SEC
FIND TDH Qp = individual pump capacity, m3/s
HS= 4.24 M Cu = unit conversion coefficient = 0.935
HM= 0.02 M D = outside diameter of pump bell/volute, m
HF= 8.32 M S = height from lowest pumping level to pump bell/volute, m
TDH= 12.57 M
hf=(10.67�^1.85)/(�^1.85�^4.87)xL
Sewer Pumpstation Design Calculations For Alqibla Project
PUMPSTATION HYDRAULIC CALCULATION
SELECT PUMPS
#PUMPS= 2
Q MAX= 15446.805 m3/day
Q MAX= 350.000 m3/HR
Q MAX= 5.833 m3/MIN
Q MAX= 0.097 M3/SEC
TDH= 12.573 M
18.5
16
13.5
11
8.5
6
0 0.05 0.1 0.15 0.2 0.25 0.3
Q M3/SEC
3.5
3
2.5
2
1.5
1
0.5
0
-0.5882518519
-0.5
-1
Sewer Pumpstation Design Calculations For Alqibla Project
PUMPSTATION HYDRAULIC CALCULATION
CHECK PUMP
3.5
HEAD= 12.57317977 M 3
Q= 0.0972222222 M3/SEC
2.5
Q= 5.8333333333 M3/MIN
Q= 350 M3/HR 2
Q= 8400 M3/DAY 1.5
PUMP HIGH= 1 M 1
OPERATION CYCLE= 15 0.5
LWD= 1 M 0
DETENSTION TIME= 4 MIN -0.5882518519
ACTIVE VOLUME= 5.8333333333 M3 -0.5 WLMIN
WELL CROSS AREA= 9 M3 -1
ACTIVE DEPTH= 0.6481 M 0
-0.2
LWL= -1.2364 M
-0.4
MAX WL= -0.588 M -0.6 P WL
WATER IN PIPE LEVEL 0.44 M -0.8
d/D LEVEL= 0.5386 M -1 0.0
-1.2 WLMAX
PIPE CROWN LEVEL= 0.7136 M
-1.4
HOUSE CONNECTION SUMP LEVEL= 2.35 M
DEEPUST DEPTH OF NET WORK= 3.14 M P WL PINV WLMAX WLMIN
0.4 0.0136 -0.588251852 -1.2364
Sewer Pumpstation Design Calculations For Alqibla Project
PUMPSTATION HYDRAULIC CALCULATION
STRUCTUR CALCULATION FOR HDPE
Loading Information Load Class Pl, lb
Fill height above top of pipe H 49.2 in 1.25 m Field Equipment 10,000
Water height above top of pipe Hw 0 in 0 m H15 12,000
Soil Density gs 120 lbs/ft3 1.92 t/m3 H20 16,000
Vehicle Load on pipe (NEH 636, 52-7 Pl 10000 lbs 5 t
Impact Factor (NEH 636, 52-8) If 1 converter unte
Pressure from the fill above the pipe Ps 3.41754156 psi 2.402769502 t/m2 from to factor
Hydrostatic pressure above the pipe PG 0 psi 0 t/m2 in m 0.0254
Vacuum pressure in the pipe (0 to 5 p Pv 0 psi 0 t/m2 lbs/ft3 t/m3 0.01601846
Wheel Load Felt by the pipe Pw 1.34825273 psi 0.947915482 t/m2 lbs t 0.0005
Total External Pressure on pipe P 4.76579429 psi 3.350684983 t/m2 psi t/m2 0.7030695783
Pipeline Information (Solid Wall HDPE) in2 m2 0.000645
Input nominal diameter of Pipe 11.8 in 0.3 m lb/ft t/m 0.00147636
Input Standard Dimension Ratio SDR 17 KPA T/M2 0.101972
Input the Pipe Pressure Rating PR 2.4 psi 1.687366988 t/m2 lbs T 0.0005
Pipe Modulus of Elasticity, short te E 110000 psi 77337.65361 t/m2 FT M 0.3048
Pipe Modulus of Elasticity, long ter Elong 22000 psi 15467.53072 t/m2
Section Modulus, (Pipe Wall Moment Ipw 0.00011092 in4/in
Input Pipe Wall Thickness t 0.11 in 0.002794 m
Input Pipe Outside Diameter OD 12.0310236 in 0.305588 m
Pipe Inside Diameter ID 11.8110236 in 0.3 m
Mean Diameter Dm 11.9210236 in 0.302794 m
Actual Pipe Wall Area Aapw 0.11 in2/in 0.00007095 m2/m
Sewer Pumpstation Design Calculations For Alqibla Project
PUMPSTATION HYDRAULIC CALCULATION
Wall Crushing
Thrust in Pipe wall Tpw 344.02 lb/ft 0.51 t/m
Required Wall Area (long term) Apw 0.04 in2/in 0.00 m2/m Pipe wall will not crush
Actual Pipe Wall Area Aapw 0.11 in2/in
Deflection (%DX/D<=7.5% for pipes other than spillway conduits)
Deflection Lag Factor (NEH 636, 52-1 DL 1.00
Bedding Constant (NEH 636, 52-11 [0 K 0.10
Modulus of soil reaction (see table E' 400.00
Deflection %DX/D 1.13 % Deflection is within limits
Buckling
Buckling Factor of Safety (NEH 636, FS 2.50
Water Buoyancy factor (NEH 636, 52 Rw 1.00
Coefficient of Elastic Support (NEH B' 0.66
Buckling Reduction Factor (NEH 636, C 0.90
Wall Buckling Critical Pressure qa 1.24 psi 0.87 t/m2 Buckling will occur!
Pressure Applied by Permanent Loa Pp 3.42 psi 2.40 t/m2
Strain (eall<=5%)
Hoop Strain eh 0.002348 in/in 0.0023477 m/m
Vertical decrease in diameter DY 0.1343 in 0.0034112 M
Flexural Strain ef 0.000036 in/in 0.0000356 M/M
Combined Strain e 0.24 % 0.24 % Pipe Strain is not a problem
Sewer Pumpstation Design Calculations For Alqibla Project
PUMPSTATION HYDRAULIC CALCULATION
Foundation Information
Shape SQ SQ, CI, CO, or RE
B= 5.2 m
L= 5.2 m
D= 5.3864 m
Soil Information
c= 12.6 kPa
phi = 30 deg
gamma = 180 kN/m^3
Dw = 1.15 m
Factor of Safety
F= 3
Sewer Pumpstation Design Calculations For Alqibla Project
PUMPSTATION HYDRAULIC CALCULATION
Unit conversion 1000
Gamma w = 9.8
phi (radians) 0.524
Terzaghi Computations
a theta = 3.35
Nc = 37.16
Nq = 22.46
N gamma = 20.12
gamma' = 170.2
coefficient #1 = 1.3
coefficient #3 = 0.4
sigma zD' = 928.04
W sub f 0
Bearing Capacity
q ult = 28569.82 kPa 2913.3216118644 T/M2
qa= 9523.27 kPa 971.1072039548 T/M2
5.8864
SURCHARGE WEIGH= 10 TON
TOTAL WEIGH= 101.72286 TON
BC 3.7619400888 TON/M2 NO COMP. PILE NEED
SUBMERCY VOLUME= 59.691396 M3
up ward force = 59.691396 TON NO BOYANCY CASE
Sewer Pumpstation Design Calculations For Alqibla Project
PUMPSTATION HYDRAULIC CALCULATION
SUMMARY SEWAGE
Notes:
1. Distributed load w can
include the weight of the beam
pluss any additional distributed
load.
W 2D
w 2D
X 5D
Y 4D
Z1 5D
Z2 5D
0 – 10 degrees
0 – 10 degrees
10 degrees max.
Qp = individual pump capacity, m3/s
Cu = unit conversion coefficient = 0.935
D = outside diameter of pump bell/volute, m
S = height from lowest pumping level to pump bell/volute, m
BEAM SPREADSHEET CALCULATIONS
© Copy Write John Andrew P.E. 15 Aug 2010
Nomanclature
a = load location from left end, in
b = load location from right end, in
E = modulus of elasticity, lbs/in2
Fa = allowable stress, lbs/in2
I = section second moment of area about the horizontal X-X axis, in4
L = beam span in inches
Lf = beam span in feet
M = beam or truss moment, in-lbs
P = concentrated load, lbs
R = support reaction force, lbs
SF = safety factor
Sx = beam section modulus about the horizontal axis, in3
V = beam shear force, lbs
w = beam weight per foot, lb/ft
x = location on beam, in
y = beam vertical deflection under load, in
θ = beam end slope, rad or deg
Ref: http://www.linsgroup.com/MECHANICAL_DESIGN/Beam/beam_formula.htm
SAMPLE AISC STANDARD WIDE FLANGE BEAMS
w Ix Sx
BEAM CALCULATION METHOD lb/ft in^4 in^3
W12x40 40 307 51.50
Step-1 Type beam load and properties W12x72 72 597 97.40
data under "Input" below. W12x120 120 1070 163.0
The beam data in yellow above is copied and pasted into the "INPUT"
data cells below.
Input the maximum moment, allowable stress and safety factor below and use the
AISC spreadsheet table to calculate the beam section modulus Sx that will support
the moment M at the allowable bending stress Fa.
Determine Steel Member Section Size based on estimated section modulus Sx
INPUT
Moment in beam, M = 190000 in-lbs
Allowable material stress, Fa = 22000 lbs/in^2
Design Safety Factor, SF = 2.50
CALCULATE
Required beam section modulus, Sx = SF * M / Fa
= 21.59 in^3
There may be more than one beam section with the required Sx or slightly
larger.
Ref: http://www.linsgroup.com/MECHANICAL_DESIGN/Beam/beam_formula.htm
This is the end of this Worksheet
INVE.inlet
ZONE G.L of street SERVIED AREA ha i mm/hr C
pipe m W2
M1 3.15 76.3 17 0.5 -0.7 0.7
lforcemain LW depth 1 POWER one pump
PIPE Dai m LW depth2 (HEATING) Distance B
length (VOTEX) KW K
1300 1.2 0.3 1 60 1.6 1
MIN. DEPTH FROM
CAST
PIPE TO SUMP AVILBLE CAST WIDTH
LENGTH
(CASTED) L B C J
3 2.25 3 0.6 1.6 0.7 1.6
Axis Title
WIDTH Active depth CHDPE d/D force main area WL GULLY WL STREET
2.40 3.00 140.00 0.90 0.38 2.18 1.05
@TIDE
pump no Q ump
1
3 20 0.7 0.7
1.5 Qpump m3/hr Qpm3/min WIDTH
m3/sec
3 2161.83
36.03 0.60 OK
WELL DIMENSION
ZONE SH1 ZONE SH1
WELL TYPE SEWAGE
SITE DATA 1 SEWAGE DESIGN PARAMETERS 3 SOIL INPUT 4 FORCE MAIN STRUCTURAL 7 STORM DESIGN PARAMETERS SOIL INPUT
GL 3.15 M PF 3 GAMMA WATER 1 T/M3 PIPE COVER 1.25 M GAMMA WATER T/M3
UP IPL@ MANHOLE 0.04 M RF 0.9 GAMMA DRY SOIL 1900 T/M3 SDR 17 GAMMA DRY SOIL T/M3
IPDIA 0.7 M MIN SLOPE 0.0012 C COHESION 12 T/M2 Pipe Pressure Rating 2.4 T/M2 MIN SLOPE 0.001 C COHESION T/M2
# HOUSES 540 NO MAX d/D FOR DN<=250 0.5 ANGLE FRICTION 30 DEG Impact Factor (NEH 636, 1 MAX d/D FOR DN<=250 0.5 ANGLE FRICTION DEG
CAP./HOUSE NOW 10 NO MAX d/D PIPE> DN 250 0.75 SF 3 Pressure from the fill ab 76.3 T/M2 MAX d/D PIPE> DN 250 0.75 SF 3
GR 0.03 MAX Qtotal/Qfull 0.8 Vehicle Load 5 T Hydrostatic pressure ab 0.5 T/M2 MAX Qtotal/Qfull 0.8
DESIGN AGE 25 YEAR #PIPES 1 Vacuum pressure in the pi 17 T/M2 #PIPES 1
CONSUMPTION /CAP 0.46 M3/DAY n 0.011 FORCE MAIN INPUT DATA 5 Wheel Load Felt 0.948 T/M2 n 0.011 FORCE MAIN INPUT DATA
WATER TABLE 2 M FC' 25 T/M2 #PIPE 1 NO Total External Pressure 3.35 T/M2 FC' 25 T/M2 #PIPE 1 NO
FY 500 T/M2 OD 0.3 M Pipe Pressure Rating 1.789 T/M2 FY 500 T/M2 OD 315 M
LENGTH FROM MANHOLE 22 M ID 0.25 M Elasticity,SHORT TERM 77337.65 T/M2 LENGTH FROM MANHO 22 M ID 0.29 M
HOUSE CONNECT SUMP L. 2.25 M PWALL THICK 0.025 M Elasticity, long term 15467.5 T/M2 HOUSE CONNECT SUMP 2.25 M PWALL THICK 25 M
PUMPS INPU 2 LONGUST LINE LENGTH 2000 M LENGTH 500 M P Inertia) LONGUST LINE LENGTH 2000 M LENGTH 1200 M
QP 350 M3/HR WETWELL DIM W 3 M OUT LET ST L 2 M Outside Diameter M WETWELL DIM W 3M OUT LET ST L 2M
HIGH P 1 M WETWELL DIM LENGTH 3 M VELOCITY 3 M/SEC Inside Diameter M WETWELL DIM LENGTH 3M VELOCITY 3 M/SEC
WIDTH P 0.8 M DEPTH IP INV TO SUMP 2.25 M Mean Diameter M DEPTH IP INV TO SUMP 2.25 M
LWD1 0.5 M 1ST JOINT HIGH 1.25 M SCREEN INPUT DATA 6 Actual Pipe Wall Area M2 1ST JOINT HIGH 1.25 M SCREEN INPUT DATA
LWD2 1 M 2ND JOINT HIGH 3 M LENGTH 2 M M 2ND JOINT HIGH 3M LENGTH 2M
OUT P DIA M 3RD JOINT HIGH 2 M WIDTH 2 M OUT P DIA M 3RD JOINT HIGH 2M WIDTH 2M
POWER KW DEPTH ROOF AND GRAGE 0.5 M D UNDER IPL 0.25 M POWER KW DEPTH ROOF AND GRA 0.5 M D UNDER IPL 0.25 M
CYCLE 15 NO/HR WALL THIK 0.3 M WALL THIK 0.3 M CYCLE NO/HR WALL THIK 0.3 M WALL THIK 0.3 M
WEIGHT KG BASE HEAL LENGHT 0.8 M BASE THIK 0.3 M WEIGHT KG BASE HEAL LENGHT 0.8 M BASE THIK 0.3 M
B LENGTH 1.5 M BASE THICK 0.3 M HEAL LENGTH 0.8 M B LENGTH M BASE THICK 0.3 M HEAL LENGTH 0.8 M
RPN 1400 NO ROOF THICK 0.25 M CONCRETE GAMA 2.5 T/M3 RPN NO ROOF THICK 0.25 M CONCRETE GAMA 2.5 T/M3
NO. PUMP 2 CONCRETE FC' 25 T/M2 CONCRETE FC' 25 T/M2
ROOF THICK 0.25 M ROOF THICK 0.25 M
LENGTH PIPE MANHO 18 M LENGTH PIPE M 18 M
SUMMARY HWL=
POPULATION ELEVATIONS OF SCREEN TANK TDH FORCE MAIN
POP NOW= 5400.00 CAP. INV PIPE AT SCREEN = 0.02 M #PUMPS= 2.0 NO Crushing Pipe wall will not crush
POPat 25= 11306.40 CAP. SCRN SUMP L= -0.23 M Q PROVIDE= 700.0 M3/HR Deflection Deflection is within limits
Qav. at 25= 4680.85 m3/day W depth AT SCREEN= 0.68 M TDH= 12.6 M Buckling Buckling will occur!
q inf.= 1404.25 m3/day Water L.= 0.45 M CYCLE = 15.0 Strain <=5 Pipe Strain is not a problem
Qpeak= 14042.55 m3/day SCRN ROOF L.= 3.65 M VELOCITY= 2.5 M/SEC
Qtotal flow= 15446.80 m3/day GRAVEL L.= -0.53 M WATER DEPTH 1.6 M
Qtotal flow= 643.62 m3/hr TANK VOLUME= 16.65 M3 WELL VOLUM= 9.2 M3
SITE DATA SEWAGE DESIGN PARAMETERS SOIL INPUT SITE DATA SEWAGE DESIGN PARAMETERS SOIL INPUT
GL 3.15 M PF 3 GAMMA WATER T/M3 GL 3.15 M PF 3 GAMMA WATER T/M3
UP IPL@ MANHOLE M RF 0.9 GAMMA DRY SOIL T/M3 UP IPL@ MANHOLE M RF 0.9 GAMMA DRY SOIL T/M3
IPDIA M MIN SLOPE 0.001 C COHESION T/M2 IPDIA M MIN SLOPE 0.001 C COHESION T/M2
# HOUSES NO MAX d/D FOR DN<=2 0.5 ANGLE FRICTION DEG AREA HA MAX d/D FOR DN 0.5 ANGLE FRICTION DEG
CAP./HOUSE NOW NO MAX d/D PIPE> DN 2 0.75 SF 3 C NO MAX d/D PIPE> D 0.75 SF 3
GR % MAX Qtotal/Qfull 0.8 i mm/HR MAX Qtotal/Qfull 0.8
DESIGN AGE YEAR #PIPES 1 DESIGN AGE YEAR #PIPES 1
n 0.011 FORCE MAIN INPUT DATA n 0.011 FORCE MAIN INPUT DATA
FC' 25 T/M2 #PIPE 1 NO FC' 25 T/M2 #PIPE 1 NO
FY 500 T/M2 OD 315 M FY 500 T/M2 OD 315 M
LENGTH FROM MANH 22 M ID 0.29 M LENGTH FROM M 22 M ID 0.29 M
HOUSE CONNECT SUM 2.25 M PWALL THICK 25 M HOUSE CONNECT 2.25 M PWALL THICK 25 M
PUMPS INPU LONGUST LINE LENG 2000 M LENGTH 1200 M PUMPS INPU LONGUST LINE L 2000 M LENGTH 1200 M
QP M3/HR WETWELL DIM W 3 M OUT LET ST L 2 M QP M3/HR WETWELL DIM W 3M OUT LET ST L 2M
HIGH P M WETWELL DIM LENG 3 M VELOCITY 3 M/SEC HIGH P M WETWELL DIM L 3M VELOCITY 3 M/SEC
WIDTH P M DEPTH IP INV TO SU 2.25 M WIDTH P M DEPTH IP INV TO 2.25 M
LWL1 M 1ST JOINT HIGH 1.25 M SCREEN INPUT DATA LWL1 M 1ST JOINT HIGH 1.25 M SCREEN INPUT DATA
LWL2 M 2ND JOINT HIGH 3 M LENGTH 2 M LWL2 M 2ND JOINT HIGH 3M LENGTH 2M
OUT P DIA M 3RD JOINT HIGH 2 M WIDTH 2 M OUT P DIA M 3RD JOINT HIGH 2M WIDTH 2M
POWER KW DEPTH ROOF AND GR 0.5 M D UNDER IPL 0.25 M POWER KW DEPTH ROOF AND 0.5 M D UNDER IPL 0.25 M
CYCLE NO/HR WALL THIK 0.3 M WALL THIK 0.3 M CYCLE NO/HR WALL THIK 0.3 M WALL THIK 0.3 M
WEIGHT KG BASE HEAL LENGHT 0.8 M BASE THIK 0.3 M WEIGHT KG BASE HEAL LENG 0.8 M BASE THIK 0.3 M
B LENGTH M BASE THICK 0.3 M HEAL LENGTH 0.8 M B LENGTH M BASE THICK 0.3 M HEAL LENGTH 0.8 M
RPN NO ROOF THICK 0.25 M CONCRETE GAMA 2.5 T/M3 RPN NO ROOF THICK 0.25 M CONCRETE GAMA 2.5 T/M3
CONCRETE FC' 25 T/M2 CONCRETE FC' 25 T/M2
ROOF THICK 0.25 M ROOF THICK 0.25 M
LENGTH PIPE MANHOLE 18 M LENGTH PIPE M 18 M
ZONE 0 ZONE 0
WELL TSEWAGE WELL TSTORM
SITE DATA SEWAGE DESIGN PARAMETERS SOIL INPUT SITE DATA SEWAGE DESIGN PARAMETERS SOIL INPUT
GL 3.15 M PF 3 GAMMA WATER T/M3 GL 3.15 M PF 3 GAMMA WATER T/M3
UP IPL@ MANHOLE M RF 0.9 GAMMA DRY SOIL T/M3 UP IPL@ MANHOLE M RF 0.9 GAMMA DRY SOIL T/M3
IPDIA M MIN SLOPE 0.001 C COHESION T/M2 IPDIA M MIN SLOPE 0.001 C COHESION T/M2
# HOUSES NO MAX d/D FOR DN 0.5 ANGLE FRICTION DEG AREA HA MAX d/D FOR DN 0.5 ANGLE FRICTION DEG
CAP./HOUSE NOW NO MAX d/D PIPE> D 0.75 SF 3 C NO MAX d/D PIPE> D 0.75 SF 3
GR % MAX Qtotal/Qfull 0.8 i mm/HR MAX Qtotal/Qfull 0.8
DESIGN AGE YEAR #PIPES 1 DESIGN AGE YEAR #PIPES 1
n 0.011 FORCE MAIN INPUT DATA n 0.011 FORCE MAIN INPUT DATA
FC' 25 T/M2 #PIPE 1 NO FC' 25 T/M2 #PIPE 1 NO
FY 500 T/M2 OD 315 M FY 500 T/M2 OD 315 M
LENGTH FROM M 22 M ID 0.29 M LENGTH FROM M 22 M ID 0.29 M
HOUSE CONNECT 2.25 M PWALL THICK 25 M HOUSE CONNECT 2.25 M PWALL THICK 25 M
PUMPS INPU LONGUST LINE L 2000 M LENGTH 1200 M PUMPS INPU LONGUST LINE L 2000 M LENGTH 1200 M
QP M3/HR WETWELL DIM W 3 M OUT LET ST L 2 M QP M3/HR WETWELL DIM W 3M OUT LET ST L 2M
HIGH P M WETWELL DIM L 3 M VELOCITY 3 M/SEC HIGH P M WETWELL DIM L 3M VELOCITY 3 M/SEC
WIDTH P M DEPTH IP INV TO 2.25 M WIDTH P M DEPTH IP INV TO 2.25 M
LWL1 M 1ST JOINT HIGH 1.25 M SCREEN INPUT DATA LWL1 M 1ST JOINT HIGH 1.25 M SCREEN INPUT DATA
LWL2 M 2ND JOINT HIGH 3 M LENGTH 2 M LWL2 M 2ND JOINT HIGH 3M LENGTH 2M
OUT P DIA M 3RD JOINT HIGH 2 M WIDTH 2 M OUT P DIA M 3RD JOINT HIGH 2M WIDTH 2M
POWER KW DEPTH ROOF AND 0.5 M D UNDER IPL 0.25 M POWER KW DEPTH ROOF AND 0.5 M D UNDER IPL 0.25 M
CYCLE NO/HR WALL THIK 0.3 M WALL THIK 0.3 M CYCLE NO/HR WALL THIK 0.3 M WALL THIK 0.3 M
WEIGHT KG BASE HEAL LENG 0.8 M BASE THIK 0.3 M WEIGHT KG BASE HEAL LENG 0.8 M BASE THIK 0.3 M
B LENGTH M BASE THICK 0.3 M HEAL LENGTH 0.8 M B LENGTH M BASE THICK 0.3 M HEAL LENGTH 0.8 M
RPN NO ROOF THICK 0.25 M CONCRETE GAMA 2.5 T/M3 RPN NO ROOF THICK 0.25 M CONCRETE GAMA 2.5 T/M3
CONCRETE FC' 25 T/M2 CONCRETE FC' 25 T/M2
ROOF THICK 0.25 M ROOF THICK 0.25 M
LENGTH PIPE M 18 M LENGTH PIPE M 18 M
ZONE 0 ZONE 0
WELL TSEWAGE WELL TSTORM
SITE DATA SEWAGE DESIGN PARAMETERS SOIL INPUT SITE DATA SEWAGE DESIGN PARAMETERS SOIL INPUT
GL 3.15 M PF 3 GAMMA WATER T/M3 GL 3.15 M PF 3 GAMMA WATER T/M3
UP IPL@ MANHOLE M RF 0.9 GAMMA DRY SOIL T/M3 UP IPL@ MANHOLE M RF 0.9 GAMMA DRY SOIL T/M3
IPDIA M MIN SLOPE 0.001 C COHESION T/M2 IPDIA M MIN SLOPE 0.001 C COHESION T/M2
# HOUSES NO MAX d/D FOR DN 0.5 ANGLE FRICTION DEG AREA HA MAX d/D FOR DN 0.5 ANGLE FRICTION DEG
CAP./HOUSE NOW NO MAX d/D PIPE> D 0.75 SF 3 C NO MAX d/D PIPE> D 0.75 SF 3
GR % MAX Qtotal/Qfull 0.8 i mm/HR MAX Qtotal/Qfull 0.8
DESIGN AGE YEAR #PIPES 1 DESIGN AGE YEAR #PIPES 1
n 0.011 FORCE MAIN INPUT DATA n 0.011 FORCE MAIN INPUT DATA
FC' 25 T/M2 #PIPE 1 NO FC' 25 T/M2 #PIPE 1 NO
FY 500 T/M2 OD 315 M FY 500 T/M2 OD 315 M
LENGTH FROM M 22 M ID 0.29 M LENGTH FROM M 22 M ID 0.29 M
HOUSE CONNECT 2.25 M PWALL THICK 25 M HOUSE CONNECT 2.25 M PWALL THICK 25 M
PUMPS INPU LONGUST LINE L 2000 M LENGTH 1200 M PUMPS INPU LONGUST LINE L 2000 M LENGTH 1200 M
QP M3/HR WETWELL DIM W 3 M OUT LET ST L 2 M QP M3/HR WETWELL DIM W 3M OUT LET ST L 2M
HIGH P M WETWELL DIM L 3 M VELOCITY 3 M/SEC HIGH P M WETWELL DIM L 3M VELOCITY 3 M/SEC
WIDTH P M DEPTH IP INV TO 2.25 M WIDTH P M DEPTH IP INV TO 2.25 M
LWL1 M 1ST JOINT HIGH 1.25 M SCREEN INPUT DATA LWL1 M 1ST JOINT HIGH 1.25 M SCREEN INPUT DATA
LWL2 M 2ND JOINT HIGH 3 M LENGTH 2 M LWL2 M 2ND JOINT HIGH 3M LENGTH 2M
OUT P DIA M 3RD JOINT HIGH 2 M WIDTH 2 M OUT P DIA M 3RD JOINT HIGH 2M WIDTH 2M
POWER KW DEPTH ROOF AND 0.5 M D UNDER IPL 0.25 M POWER KW DEPTH ROOF AND 0.5 M D UNDER IPL 0.25 M
CYCLE NO/HR WALL THIK 0.3 M WALL THIK 0.3 M CYCLE NO/HR WALL THIK 0.3 M WALL THIK 0.3 M
WEIGHT KG BASE HEAL LENG 0.8 M BASE THIK 0.3 M WEIGHT KG BASE HEAL LENG 0.8 M BASE THIK 0.3 M
B LENGTH M BASE THICK 0.3 M HEAL LENGTH 0.8 M B LENGTH M BASE THICK 0.3 M HEAL LENGTH 0.8 M
RPN NO ROOF THICK 0.25 M CONCRETE GAMA 2.5 T/M3 RPN NO ROOF THICK 0.25 M CONCRETE GAMA 2.5 T/M3
CONCRETE FC' 25 T/M2 CONCRETE FC' 25 T/M2
ROOF THICK 0.25 M ROOF THICK 0.25 M
LENGTH PIPE M 18 M LENGTH PIPE M 18 M