Automatic and Manual Changeover Systems

Manual Bypass systems


Generator Synchronizing Systems

Designed,Manufactured and Supplied by PCTL


Contents

PCTL Alternate Source Switchgear Systems Page

Overview,Features &Applications ...............................................2/3

Manual Changeover Series TypeBMCO..........................................4


Technical Details MCOBXXS SERIES (1P+N)...................................5
Technical Details MCOBXXXXT SERIES (3P+N).................................6

Manual Bypass (16B3200A) TypeBMBPSBXXXXST...........................7


Technical Details MBPSBXXXXST SERIES .........................................8

Automatic Changeovers (16B63A) TypeBACOBXXSS..................9/10


Technical Details ACOBXXSS SERIES .............................................11

Automatic Changeovers (16B3200A) TypeBACOBXXXXST.............12


Technical Details ACOBXXXXST SERIES .........................................13

Automatic Changeovers (200B6300A) TypeBACOBXXXXCBT........14


Technical Details ACOBXXXXCBT SERIES ......................................15

Automatic Synchronizing Systems ...............................................16


Generator Componenets & Accessories.......................................17
Options.........................................................................................18
After sales service ........................................................................19
Contact us.....................................................................................20

Page-2
Overview
Features & Applications Areas of Applications
PCTL offers a wide range of manual and Agriculture (Tea, Flower, Sugar, Coffee
automatic change over systems ,these are etc.) Chemical/Petrochemical
open transisiton change overs ,each Pharmaceutical companies
change over system is designed to offer a Power Stations, Generation and
optimum solution. Distribution
Paper Industries
CO System advantages: Water projects, dams, water treatment
Mining/Quarries
BA Reliable and Optimum change over Steel Mills
system. Food Industries
B Manual over ride options(this Data centres
facility is offered in sleected ranges) Airports
BAdjustable delays for change overs Office buildings
Simple and easy settings Shopping centres
BHigh operational reliability and Hospitals
availability Learning institution’s Hotels
BCompact, spaceBsaving design

Quality Certifications
PCTL Automation is an ISO9900192008 certified company and has a documented
quality control system,all Low Voltage switchgear are stringently quality controlled to
perform under very demanding conditions ,the low voltage Change Over and Bypass
systems also carry the diamond mark of Quality as per the product certifications from
KEBS.

Page-3
Manual Change Over Systems Type@MCO@XXS
PCTL Offers a range of compact Excellent thermal and dielectric
changeover switches, designed according properties of insulating materials adjacent
to IEC / EN 60947B3, stands out for the to current carrying parts: Dielectric
easy and low B cost installation, flexB strenght, electrical track resistance and
ibility, safety and reliability . dimensional stability at high
Compact size saves panel space and temperatures .
allows the usage of a smaller enclosure .
Fully rated switched neutral pole which
closes first and opens last,enB suring
presence of neutral always in the circuit
and giving protection against accidental
overvoltage surges in equipments
connected between phase and neutral .
Suitable for isolaton as per IEC/EN
60947B3, ensuring safety of the opB erator
by eliminating chances of wrong
indication of handle position .
Robust and efficent quick make & break
mechanism opening & closing of the
contacts independent of the speed of
actuation .
High electrical and mechanical life even in
extreme tropic or arctic conditions and
the polluted environment of any process
industry thanks to:
B Silver plated copper knife type contact
system with self B wiping action and four
breaking points por pole (two double B
break contacts) .
B Moulded case design of non B flammable
glass fibre reinforced polyester with high
mechanical and electrical track resistance
and with low water absorption . B

Page-4
Technical Details Type@MCO@XXS
SINGLE PHASE

S.No Item)Description Model Imax(Amps) MOUNTING)STYLE


1 MANUAL)CHANGEOVER)16A)SINGLE)POLE+N MCO16S 16 Panel)wall)mounted
2 MANUAL)CHANGEOVER)32A)SINGLE)POLE+N MCO32S 32 Panel)wall)mounted
3 MANUAL)CHANGEOVER)40A)SINGLE)POLE+N MCO40S 40 Panel)wall)mounted
4 MANUAL)CHANGEOVER)63A)SINGLE)POLE+N MCO63S 63 Panel)wall)mounted
5 MANUAL)CHANGEOVER)100A)SINGLE)POLE+N MCO100S 100 Panel)wall)mounted
6 MANUAL)CHANGEOVER)125A)SINGLE)POLE+N MCO125S 125 Panel)wall)mounted
7 MANUAL)CHANGEOVER)160A)SINGLE)POLE+N MCO160S 160 Panel)wall)mounted
8 MANUAL)CHANGEOVER)200A)SINGLE)POLE+N MCO200S 200 Panel)wall)mounted

* Higher current ratings available on request!


* Please note that our Standard Manual change over switch comes with
changeover switch mounted in a metal enclsoure only.
Any optional items such as list below needs to be quoted additionally
1) Indicators
2) Instruments such as Voltmeter,Ameter,Energy Meters etc
3) Surge arraestors
4) Extended Busbar Links
5) Extra cable compartment for extra cables
6) Control wiring

Page-5
Technical Details Type@MCO@XXXXT
THREE PHASE

S.No Item)Description Model Imax(Amps) MOUNTING)STYLE


1 MANUAL)CHANGEOVER)16A)THREE)POLE+N MCO16T 16 Panel)wall)mounted
2 MANUAL)CHANGEOVER)32A)THREE)POLE+N MCO32T 32 Panel)wall)mounted
3 MANUAL)CHANGEOVER)40A)THREE)POLE+N MCO40T 40 Panel)wall)mounted
4 MANUAL)CHANGEOVER)63A)THREE)POLE+N MCO63T 63 Panel)wall)mounted
5 MANUAL)CHANGEOVER)100A)THREE)POLE+N MCO100T 100 Panel)wall)mounted
6 MANUAL)CHANGEOVER)125A)THREE)POLE+N MCO125T 125 Panel)wall)mounted
7 MANUAL)CHANGEOVER)160A)THREE)POLE+N MCO160T 160 Panel)wall)mounted
8 MANUAL)CHANGEOVER)200A)THREE)POLE+N MCO200T 200 Panel)wall)mounted
9 MANUAL)CHANGEOVER)250A)THREE)POLE+N MCO250T 250 Panel)wall)mounted
10 MANUAL)CHANGEOVER)315A)THREE)POLE+N MCO315T 315 Panel)wall)mounted
11 MANUAL)CHANGEOVER)400A)THREE)POLE+N MCO400T 400 Panel)wall)mounted
12 MANUAL)CHANGEOVER)630A)THREE)POLE+N MCO630T 630 FREE)STANDING
13 MANUAL)CHANGEOVER)800A)THREE)POLE+N MCO800T 800 FREE)STANDING
14 MANUAL)CHANGEOVER)1000A)THREE)POLE+N MCO1000T 1000 FREE)STANDING
15 MANUAL)CHANGEOVER)1250A)THREE)POLE+N MCO1250T 1250 FREE)STANDING
16 MANUAL)CHANGEOVER)1600A)THREE)POLE+N MCO1600T 1600 FREE)STANDING
17 MANUAL)CHANGEOVER)2000A)THREE)POLE+N MCO2000T 2000 FREE)STANDING
18 MANUAL)CHANGEOVER)2500A)THREE)POLE+N MCO2500T 2500 FREE)STANDING
19 MANUAL)CHANGEOVER)3200A)THREE)POLE+N MCO3200T 3200 FREE)STANDING

* Higher current ratings available on request!


* Please note that our Standard Manual Change Over Switch comes with
changeover mounted in a metal enclsoure.
Any optional items such as list below needs to be quoted additionally
1) Indicators
2) Instruments such as Voltmeter,Ameter,Energy Meters etc
3) Surge arraestors
4) Extended Busbar Links
5) Extra cable compartment for extra cables
6) Control wiring

Page-6
Manual Bypass Systems Type@MBPS@XXXXT

A B C D E F G H I J K L M N O P Q R S T

1 1
PCTL
SW.1 SW.2 SW.3
PROJECT NAME

2 Bypass mode. The load is supplied direct from the mains. 2


I 0 0 Recommended when servicing the AMF with load being supplied.
KPLC AUTO
CHANEOVER

Manual Bypass System Description


0 0 I Supply goes to kplc contactor but no output. BOARD
3 3

0 I 0 Supply from amf contactor output only from generator. CUSTOMER NAME

TRADEMATIX LTD
4 Inline mode. The load is supplied through the AMF. 4
0 I I
Load and AMF completely isolated.
5 O O O Recommended when servicing downstream bypass, DB, and AMF. 5
CONSULTING ENGINEER

A Manual Bypass System consists of 6 6

PROJECT REFERENCE

7 7

load break switches mechanically interlocked,to 8

MANUAL CHANGEOVER 2
200A 4P
8

200A 4P

provide load break isolation and also have


9 9

10 10

bypass transfer power contacts ,therefore in

Designed and Manufactured By


1L1 3L2 5L3 1L1 3L2 5L3
11
7L4 7L4
11

2T1 4T2 6T3 8T4 2T1 4T2 6T3 8T4

12 12
250A 4P
ISOLATOR

situations where a manual bypass is required 13

14
13

14

due to one reason or other,this can be


SLD

15 15

16 16

accomplished safely and efficiently by utilizing A B C D E F G H I J K L M N O P Q R S PCTL

MBPS.PCTL Automation manufactures a wide


range of open transition manual bypass
switches,covering the complete power
range ,these swithces are aesthetically
enclosed in metallic enclosures to provide a
safe easy and rapid action Bypass
switches ,fully rated,self cleaning contacts
provides a reliable solution for through out its
service life.

Application Description

The bypass isolation system is


mandatory for applications where
maintenance, inspection and testing is to be
perform, while maintaining continuous power to
the load. The application also inclludes critical
life support systems and standby power
situations requiring safe system maintenance
with no power disruptions. Such a design allows
for the quick isolation of the different devices
such as automatic change over-
systems,UPS,Volatge stabilizers ,fuel cells etc
for inspection, maintenance or replacement
purpose.

Page-7
Technical Details Type@MBPS@XXXXT
THREE PHASE

S.No Item)Description Model Imax(Amps) MOUNTING)STYLE


1 MANUAL'BYPASS',16AMPS,THREE'POLE+N MBPS16T 16 WALL'MOUNTED
2 MANUAL'BYPASS',32AMPS,THREE'POLE+N MBPS32T 32 WALL'MOUNTED
3 MANUAL'BYPASS',64AMPS,THREE'POLE+N MBPS64T 64 WALL'MOUNTED
4 MANUAL'BYPASS',80AMPS,THREE'POLE+N MBPS80T 80 WALL'MOUNTED
5 MANUAL)BYPASS),100AMPS,THREE)POLE+N MBPS100T 100 WALL)MOUNTED
6 MANUAL'BYPASS',125AMPS,THREE'POLE+N MBPS125T 125 WALL'MOUNTED
7 MANUAL'BYPASS',160AMPS,THREE'POLE+N MBPS160T 160 WALL'MOUNTED
8 MANUAL'BYPASS',200AMPS,THREE'POLE+N MBPS200T 200 WALL'MOUNTED
9 MANUAL'BYPASS',250AMPS,THREE'POLE+N MBPS250T 250 WALL'MOUNTED
10 MANUAL)BYPASS),315AMPS,THREE)POLE+N MBPS315T 315 WALL)MOUNTED
11 MANUAL'BYPASS',400AMPS,THREE'POLE+N MBPS400T 400 WALL'MOUNTED
12 MANUAL'BYPASS',500AMPS,THREE'POLE+N MBPS500T 500 FREE'STANDING
13 MANUAL'BYPASS',630AMPS,THREE'POLE+N MBPS630T 630 FREE'STANDING
14 MANUAL'BYPASS',800AMPS,THREE'POLE+N MBPS800T 800 FREE'STANDING
15 MANUAL)BYPASS),1000AMPS,THREE)POLE+N MBPS1000T 1000 FREE)STANDING
16 MANUAL'BYPASS',1250AMPS,THREE'POLE+N MBPS1250T 1250 FREE'STANDING
17 MANUAL'BYPASS',1600AMPS,THREE'POLE+N MBPS1600T 1600 FREE'STANDING
18 MANUAL'BYPASS',2000AMPS,THREE'POLE+N MBPS2000T 2000 FREE'STANDING
19 MANUAL'BYPASS',2500AMPS,THREE'POLE+N MBPS2500T 2500 FREE'STANDING
20 MANUAL)BYPASS),3200AMPS,THREE)POLE+N MBPS3200T 3200 FREE)STANDING

* Higher current ratings available on request!


* Please note that our Standard Manual Bypass Switch comes with changeover
and load break switch mounted with in a metal enclsoure only.
Any optional items such as list below needs to be quoted additionally
1) Indicators
2) Instruments such as Voltmeter,Ameter,Energy Meters etc
3) Surge arraestors
4) Extended Busbar Links
5) Extra cable compartment for extra cables
6) Control wiring

Page-8
Automatic Change Over Systems
Type@PCTL@ACO@XXSS
PCTL Offers a wide range of
automatic open transition changeover
switches, designed for the easy low B cost
installation, at the same time offering
flexibility, safety and reliability . TO LOAD

The design consists of operating


twin double pole Isolators by using a
M Manual
o Off
A Auto M

Motorized

mechanically interlocked and driven


control

motor mechanism the design


incorporates the closing of single isolator
at one instance of time ,this combination
can also be used to privide mcb,s in place
of isolators for dual protection of thermal
for overloads and magnetic for short
circuit ,the advantage of using the
motorized mechanism is that the
switching postions of the isolators are
stable and unlike contactors does not
require contineous power for mantaining
the position,at the same time offering a
duel protection.
Advantages
1) Simple and Easy Operation with space
saving design.
2) Manual overide mechanisn in built with
in motor mechanism,allows the manual
selection of one or other source.
3) The stable positions either under ON or
OFF does not requires any supply to
maintain these positions unlike
contactors where the coil burning is
common phenomenon,specially in a
polluted environment

Page-9
4) Can provide both protection Boverload
and short circuit.
5) Under/Over voltage adjustment with
On delay.
6) Status indications.
7) Other options can be quoted separately
on request.
!! NO MORE BURNING OF CONTACTOR COILS !!
Advantage of the PCTL Standard
range of the automatic change over
switch over isolating contacts type is that
the operation of the motor operator
requires supply,only during short interval,
when switch over is required from one
source to other,after the transition the
contacts remain in stable position and do
not require any power,thereby reducing
the stress of abnormal control supply on
their operating conditions.
Second advantge is that it can be
offered with thermal and shortcuit
protections by utiizing the mcb,s for
switching from one source to
another,instead of contacts.
Third advantage is that in case of
the automode failure immediately the
supply can be fed from one source or
another by using integral bypass .
Fourth advantage is small foot
prints requires a smaller and compact
design.

Page-10
Technical Details Type@ACO@XXSS
SINGLE PHASE

S.No Item)Description Model Imax(Amps) MOUNTING)STYLE


1 AUTOMATIC)CHANGE)OVER))16ASP)(1P+N) ACO16SS 16 WALL)MOUNTED
2 AUTOMATIC)CHANGE)OVER))32ASP)(1P+N) ACO32SS 32 WALL)MOUNTED
3 AUTOMATIC)CHANGE)OVER))40ASP)(1P+N) ACO40SS 40 WALL)MOUNTED
4 AUTOMATIC)CHANGE)OVER))50ASP)(1P+N) ACO50SS 50 WALL)MOUNTED
5 AUTOMATIC)CHANGE)OVER))63ASP)(1P+N) ACO63SS 63 WALL)MOUNTED

* Higher current ratings available on request!


* Please note that our Standard Automatic Change Over comes with standard
features only mounted with in a metal enclsoure,refer drawings supplied.
Any optional items such as list below needs to be quoted additionally
1) Indicators
2) Instruments such as Voltmeter,Ameter,Energy Meters etc
3) Surge arraestors
4) Extended Busbar Links
5) Extra cable compartment for extra cables
6) Control wiring

Page-11
Automatic Change Over Systems
Type@PCTL@ACO@XXXXST
PCTL Offers a wide range of
automatic open transition changeover
switches, designed for the easy low B cost
TO LOAD

installation, at the same time offering


flexibility, safety and reliability . M Manual
o Off
A Auto M

Motorized

The design consists of operating


control

twin four pole Isolators by using a


mechanically interlocked and driven
motor mechanism the design
incorporates the closing of single isolator
at one instance of time ,the advantage of
using the motorized mechanism is that
the switching postions of the isolators are
stable and unlike contactors does not
require contineous power for mantaining
the position.

Advantages
1) Simple and Easy Operation with space
saving design.
2) Manual overide mechanisn in built with
in motor mechanism allows the manual
selection of one over other source.
3) The stable positions either under ON or
OFF does not requires any supply to
maintain these positions unlike
contactors where the coil burning is
common phenomenon specially in a
polluted environment

Page-12
Technical Details Type@ACO@XXXXST
THREE PHASE

S.No Item)Description Model Imax(Amps) MOUNTING)STYLE


1 AUTOMATIC)CHANGEOVER)16A)THREE)POLE+N ACO16ST 16 Panel)wall)mounted
2 AUTOMATIC)CHANGEOVER)32A)THREE)POLE+N ACO32ST 32 Panel)wall)mounted
3 AUTOMATIC)CHANGEOVER)40A)THREE)POLE+N ACO40ST 40 Panel)wall)mounted
4 AUTOMATIC)CHANGEOVER)50A)THREE)POLE+N ACO50ST 50 Panel)wall)mounted
5 AUTOMATIC)CHANGEOVER)63A)THREE)POLE+N ACO63ST 63 Panel)wall)mounted
6 AUTOMATIC)CHANGEOVER)100A)THREE)POLE+N ACO100ST 100 Panel)wall)mounted
7 AUTOMATIC)CHANGEOVER)125A)THREE)POLE+N ACO125ST 125 Panel)wall)mounted
8 AUTOMATIC)CHANGEOVER)160A)THREE)POLE+N ACO160ST 160 Panel)wall)mounted
9 AUTOMATIC)CHANGEOVER)200A)THREE)POLE+N ACO200ST 200 Panel)wall)mounted
10 AUTOMATIC)CHANGEOVER)250A)THREE)POLE+N ACO250ST 250 Panel)wall)mounted
11 AUTOMATIC)CHANGEOVER)315A)THREE)POLE+N ACO315ST 315 Panel)wall)mounted
12 AUTOMATIC)CHANGEOVER)400A)THREE)POLE+N ACO400ST 400 FREE)STANDING
13 AUTOMATIC)CHANGEOVER)500A)THREE)POLE+N ACO500ST 500 FREE)STANDING
14 AUTOMATIC)CHANGEOVER)630A)THREE)POLE+N ACO630ST 630 FREE)STANDING
15 AUTOMATIC)CHANGEOVER)800A)THREE)POLE+N ACO800ST 800 FREE)STANDING
16 AUTOMATIC)CHANGEOVER)1000A)THREE)POLE+N ACO1000ST 1000 FREE)STANDING
17 AUTOMATIC)CHANGEOVER)1250A)THREE)POLE+N ACO1250ST 1250 FREE)STANDING
18 AUTOMATIC)CHANGEOVER)1600A)THREE)POLE+N ACO1600ST 1600 FREE)STANDING
19 AUTOMATIC)CHANGEOVER)2000A)THREE)POLE+N ACO2000ST 2000 FREE)STANDING
20 AUTOMATIC)CHANGEOVER)2500A)THREE)POLE+N ACO2500ST 2500 FREE)STANDING
21 AUTOMATIC)CHANGEOVER)3200A)THREE)POLE+N ACO3200ST 3200 FREE)STANDING

* Please note that our Standard Automatic Change Over comes with standard
features only mounted with in a metal enclsoure.Please request for the drawing
for additional information.
Any optional items such as list below needs to be quoted additionally
1) Indicators
2) Instruments such as Voltmeter,Ameter,Energy Meters etc
3) Surge arrestors
4) Extended Busbar Links
5) Extra cable compartment for extra cables
6) Control wiring

Page-13
Automatic Change Over Systems
Type@PCTL@ACO@XXXXCBT

PCTL Offers a wide range of


automatic open transition changeover
switches, designed for a very
advanced ,robust and reliable,flexible,safe
and relaible.
The design consists of operating
four pole circuit breakers fully automatic
in electrically and mechanically
interlocked to provide automatic source
selection, from one source to
another ,the change over sequenc is
controlled by an industrial grade logic
controller which provide the sequences
with adjustable delays inorder to achieve
successful change overs repeatedly, the
logic incorporation also provides a
flexibility of integrating various options
with in the change overs,inorder to make
it more efficient .
Advantages
1) Possibility of integrating complex
sequences.
2) Facility of programming gensets to run
equal hours in a system of multiple
gensets .
3) Remote operation possibility by using
standard communication protocols.

Page-14
Technical Details Type@ACO@XXXXCBT
THREE PHASE

S.No Item)Description Model Imax(Amps) MOUNTING)STYLE


1 AUTOMATIC)CHANGEOVER)200A)THREE)POLE+N ACO200CBT 200 Panel)wall)mounted
2 AUTOMATIC)CHANGEOVER)250A)THREE)POLE+N ACO250CBT 250 Panel)wall)mounted
3 AUTOMATIC)CHANGEOVER)315A)THREE)POLE+N ACO315CBT 315 FREE)STANDING
4 AUTOMATIC)CHANGEOVER)400A)THREE)POLE+N ACO400CBT 400 FREE)STANDING
5 AUTOMATIC)CHANGEOVER)500A)THREE)POLE+N ACO500CBT 500 FREE)STANDING
6 AUTOMATIC)CHANGEOVER)630A)THREE)POLE+N ACO630CBT 630 FREE)STANDING
7 AUTOMATIC)CHANGEOVER)800A)THREE)POLE+N ACO800CBT 800 FREE)STANDING
8 AUTOMATIC)CHANGEOVER)1000A)THREE)POLE+N ACO1000CBT 1000 FREE)STANDING
9 AUTOMATIC)CHANGEOVER)1250A)THREE)POLE+N ACO1250CBT 1250 FREE)STANDING
10 AUTOMATIC)CHANGEOVER)1600A)THREE)POLE+N ACO1600CBT 1600 FREE)STANDING
11 AUTOMATIC)CHANGEOVER)2000A)THREE)POLE+N ACO2000CBT 2000 FREE)STANDING
12 AUTOMATIC)CHANGEOVER)2500A)THREE)POLE+N ACO2500CBT 2500 FREE)STANDING
13 AUTOMATIC)CHANGEOVER)3200A)THREE)POLE+N ACO3200CBT 3200 FREE)STANDING
14 AUTOMATIC)CHANGEOVER)4000A)THREE)POLE+N ACO4000CBT 4000 FREE)STANDING
15 AUTOMATIC)CHANGEOVER)5000A)THREE)POLE+N ACO5000CBT 5000 FREE)STANDING
16 AUTOMATIC)CHANGEOVER)6300A)THREE)POLE+N ACO6300CBT 6300 FREE)STANDING

* Lower current ratings available on request!


* Please note that our Standard Automatic Change Over comes with standard
features only,for more information kindly request for the detailed options offered
with our standard models.
Any optional items such as list below needs to be quoted additionally
1) Indicators
2) Instruments such as Voltmeter,Ameter,Energy Meters etc
3) Surge arraestors
4) Extended Busbar Links
5) Extra cable compartment for extra cables
6) Control wiring

Page-15
Automatic Generator Synchronizing Systems
PCTL Offers a complete paralleling 3) Simplicity and adaptability with various
and synchronizing solution based on different gensets manufacturers.
customers requirement 4) N combination with mains paralleling.
The system can offer load based
management system with fully automatic
control thereby reducing the operational
costs .
The advance controllers utilized in
the synchronizing systems provides a
power full,inbuilt logic module to take
control of the automatic sequence control
the reliable solution eliminates the use of
the externally mounted plc modules and
hard wiring .
A common signal bus protocol adequately
equips the controllers to communicate
with most of the major manufacturers of
the generators thereby making it easier to
offer solutions for various types of
euipments working in synchronism with
each other .
A remote generator monitoring solution is
also available inorder to maintain a
updated operational data for the
monitoring and maintennace purpose .
Advantages
1) Simple and Easy Operation with space
saving design.
2) Complex control equations
programmed into the controller with
ease.

Page-16
Generator Control and Accessories
PCTL Offers a wide range of
controllers for Generators and paralleling

a) Battery chargers An efficient constant


voltage charger
• From 3 to 40Amps with or without
failure output relay
• Products available in 12V or 24V /
50Hz or 60Hz
• Single or three phase
• Current input range from 85 to 550VAC.
The failure output relay notifies a failure on
the integrated protections.

b) Generator controllers for


complete engine controls

c) Synchroscopes and load


sharing units

d) Paralleling modules full control


remote monitoring solutions

Page-17
Options

Surge arrestors Installation rules


PCTL Automation integrates various Wiring diagrams according to the earthing system

types of surge arrestors with in the


Three-phase + Neutral TNS system
distribution systems it manufactures, L1

depending on the application, the surge L2

arrestor captures the high energy spikes


L3

travelling through the network and


Circuit-breakers

provides a safe absorption passage, or fuses

thereby protecting the sensitive


electronic loads with in the Sub-distribution
board

installation,various classes of protections


OVR HL 4L 15 440 s P TS OVR 3N 15 275

Main

are offered based on the installation,the


switchboard

PE

visual indicators on the surge arrestors


also confirm the useful life over and can Single-phase TT system
L

be optionally replaced without touching N

the cables. Circuit-breakers


or fuses

Instruments Sub-distribution
board

Various instruments can be Main


switchboard OVR HL 2L 15 440 s P TS OVR 1N 15 275

integrated into the change over systems


as per customers request . PE

ABB Lightning Protection Group


FRSOX 0

Page-18
After Sales Service
PCTL Automation places a strong
emphasis on after sales service in order to
provide optimum performance from the
supplied products.
The availability of the product and the
performance of the same, is related to the
useful life of the switchgear ,as the the electrical equipment's laced with latest
component ageing process increases the knowhow in maintenance , with a more
chances of the breakdown and an efficient proactive approach, the advantage of these
plan has to be implemented for the longer maintenance ,is that equipment performs
trouble free operation of the at optimum level for a longer period
switchgear ,PCTL provides commissioning thereby reducing losses accrued due to
on the switchgear with the optional machine down times.
installation services ,during these PCTL provides product training on the
commissioning the operators are also following
trained on the switchgear operations. A • Installation and commissioning
more detailed training,specific on any • Service planning
product is provided with in PCTL training • Hardware and software support
centre ,with a very able and experienced • Upgrades, expansions and modifications
trainers PCTL provides hands on training on • Spare parts support and advise
the products for better understanding. Annual Maintenance Contract
PCTL also has a full fledged customer PCTL on request can offer a comprehensive
support and servicing department with full maintenance plan depending on the
annual maintenance contract on offer. customer requirement and the data
These contracts are for the maintenance of collected from the existing operational
machines .

PRO ACTIVE MAINTENANCE MAINTENANCE


EQUIPMENT AVAILABILITY PERIOD

PREVENTIVE MAINTENANCE

BREAKDOWN MAINTENANCE

PRODUCT LIFE CYCLE (TIME)

Page-19
Contact us
Contact details

PCTL AUTOMATION LIMITED


An ISO-9001-2008 Company
P.O.Box-683-0060
Location-Office No. 3 on LR No. 209/9721
(Near Panari Hotel,Mombasa Road )
Nairobi,
Kenya

Phone: +254 20 828648,828070


Wireless: +254 20 2025354, 2012193
Mobile:+254-(722-816124/734-339594)
Fax: +254 20 828648, 828070

DocumentBpctl/2014BdbeB002
e-mail-info@pctlautomation.com
www.pctlautomation.com
PCTL AUTOMATION LIMITED
, P.O.Box-683,Mombasa Road, Nairobi
+254 20 828648

Electrical Engineer · Be the first to review

Map data ©2014 Google 200 m

Das könnte Ihnen auch gefallen