Abstract
New spiral wound element improvements have been made so that RO/NF products are more robust. One
improvement is the design of vents in the seal carrier or ATD’s on the ends of the elements. This feature has proven
to quickly equalize the pressure on the inside of and outside of the element and prevent rupture of the FRP shell.
A second improvement is the development of feed spacers which have lower pressure drop. Thicker spacers with
a unique geometry have been shown to have less pressure drop and reduce the frequency of chemical cleaning
when treating water of poor feed quality.
Keywords: ATD; Feed spacer; FRP; Spiral wound element
Presented at the conference on Desalination and the Environment. Sponsored by the European Desalination Society
and Center for Research and Technology Hellas (CERTH), Sani Resort, Halkidiki, Greece, April 22–25, 2007.
and lower pH, as well as stability at higher differential can rupture the shell and irreversibly
temperatures. damage the element. This paper will discuss the
Two items have recently received more atten- issues associated with poor versus effective
tion to give better performance of the spiral wound venting of air at this position.
element. One item is the seal carrier or ATD. The other item which has received attention
Historically, this part, which is placed at both ends is the design of the feed spacer. This material
of the spiral wound element, has had two roles — is responsible for maintaining a flow channel
one being to carry the U-cup brine seal which between the two faces of membrane in the spiral
prevents feed liquid by-passing the membrane. wound element. The feed spacer must provide a
The other function is to support the back face of clear path for flow of the water, promote turbu-
the element and prevent the membrane leaves lence to keep the saline solution mixed and should
from telescoping due to the pressure differential have minimal pressure drop for water traveling
across the element. The former function is pro- tangentially to the membrane. For a system with
vided on the upstream side of the element, while good pretreatment, the feed spacer can be quite
the latter is provided on the down-stream side. narrow and function well. This allows the element
One role of the seal carrier has been little designer to pack the maximum area in the ele-
understood, which is the venting of the air from the ment. However, for poor quality feedwater, the
pressure vessel. In a commercial RO/NF system, fouling tendency of the water is much higher
there are usually 6–8 elements in a pressure and can rapidly plug the channels created by the
vessel. Due to the presence of the u-cup brine seal, feed spacer. This results in a higher operating
water does not readily flow around the outside of pressure and more frequent cleaning. With the
the spiral wound element. As the water flows on use of RO/NF technology for more surface water
the inside of the element, it becomes pressurized applications, there is a need to optimize the feed
to the feed pressure, which can be 60 to 80 bar spacer design for more difficult applications.
for seawater applications. In some cases, espe-
cially when starting a new system, there can be
air on the outside of the element, in the annular 2. Seal carrier improvements
gap between the element and the vessel. This A detailed analysis of pressures and water
annular gap can also be partially full of water, flow in a multi-element vessel has revealed that
which is common if there is some drain down there are issues related to purging air from a pres-
of liquid when an operating plant is stopped. In sure vessel due to the U-cup seals preventing the
either case, the air in this gap must be purged natural flushing of the annular gap. Fig. 1 shows
from the system. Since there is no flow path for a schematic diagram of a pressure vessel with
water around the outside of the element, the air RO elements. In Fig. 1a, the vessel does not con-
must be removed and displaced with water tain any water, while in Fig. 1b, the schematic
where the two elements contact the face of each shows water in the vessel immediately after the
other or by-passing the U-cup seal. This venting first addition of water.
can be difficult due to the differential pressure It can be seen that the water easily floods the
across the elements in the vessel which forces vessel in front of the first element by displacing
the two seal carriers tightly together. For systems the air down through the elements. Also, the water
that ramp pressure up too quickly, the air in the fills the back of the vessel all the way to the U-cup
annular gap may not be quickly removed. This seal of the last element. The air is displaced out
results in a large pressure differential across the of the vessel. However, the U-cup seal prevents
epoxy fiberglass shell. In some cases this pressure the water from going to the next to last element.
C. Bartels et al. / Desalination 221 (2008) 207–214 209
1a
Water flow
Spiral element 3 Spiral element 2 Spiral element 1
Water flow
Fig. 1. Schematic of spiral elements in a pressure vessel, (a) after loaded and before water introduced, (b) Just after
water first starts to enter the vessel.
The only way to get the air out of the annular gap The new design incorporates a number of recessed
of elements 1 and 2 is to pressurize the water so areas in the seal carrier which act as vents (Fig. 3).
it will flow past the U-cup seal; however, the air When two opposing seal carriers are face to
would then have to go against the seal to escape face, these small gaps provide an opening which
or go forward in the vessel to the next element allows the water to flow through (usually at the
position. Alternatively, the water may flood the bottom of the seal carrier) and the air to pass
annular gap by pressurizing the feedwater so it through (usually through the top of the seal
will separate the two facing seal carriers between carrier). Since each element has this feature, the
1 and 2 or 2 and 3. This would allow water into annular gaps can rapidly fill with water and the
the annular gap and air to go out through the air can be expelled.
element. Either of these mechanisms are not very
effective for venting the air from the system.
This issue is particularly problematic for sea- 3. Laboratory evaluation of pressure
water systems. In a seawater system the feed in distribution
the element is being pressurized to 60–80 bar of An experiment was performed to measure the
pressure. Until the water fully floods the annular pressures as a function of time during a typical
gap, the pressure in the gap will be much lower start-up. The experimental set-up is shown in
than in the element. This pressure differential Fig. 4. A variety of pressure gauges were installed
can lead to catastrophic damage. Fig. 2 shows an to measure pressure at different points in the vessel.
element which has a ruptured fiberglass outer- To visually observe the water flow, a pressure
wrap. This element, from an operating plant, saw vessel was made of acrylic plastic so that the
failure of the fiberglass reinforced plastic (FRP) water in the vessel could be seen. A photograph
epoxy outerwrap. It takes very high pressure of this experimental rig is shown in Fig. 5.
differentials to cause this to happen. Such pressure A picture of the edge of a new seal carrier is
can be generated when pressure ramps up quickly, shown in Fig. 3. This shows the recessed portion
and the air cannot be removed as rapidly. of the edge of the seal carrier that acts as a vent to
This issue has recently been addressed in the allow air and water to pass between the seal
development of a new seal carrier which can allow carriers. There are six of these evenly dispersed
rapid venting of the air from the annular gap. on the edge of the seal carrier. As these are only
210 C. Bartels et al. / Desalination 221 (2008) 207–214
Vents
Concentrate
P2 P1 Pi
Flow Feed tank
Permeate
a few mm deep, they do not compromise the pressure, but P2 is still about 5 bar less than Pin.
strength of the part. Thus, elements in the middle of the vessel may be
The test unit was then run to pass water to the at a greater risk of damage. Although this pressure
three elements that are in series. The water entered differential did not damage the FRP shell in this
from right to left. The pressure was measured at case, the much larger pressure differentials in
the inlet to the vessel, at the annular gap next to the seawater applications may lead to element failure.
first element, and the annular gap of the second Naturally, many other factors will also determine
element. From Fig. 6, it can be seen that the inlet if the element FRP shell will be damaged, such as
pressure rises at around 40 s. At about 60 s, the how much dP there is, and the ramp up speed of
inlet pressure has risen to about 10.0 bar while the high pressure pumps. This is one of the key
the pressure at P1 and P2 are still nearly zero. reasons why it is good to have a pump ramp-up
Thus, the pressure differential across the element speed that does not exceed 0.7 bar per second.
shell will be 10 bar. At about 80 s of operation, In contrast, Fig. 7 shows the pressure profile
the pressure at P1 has nearly equaled the inlet in a three element experiment where the new
Fig. 8. Schematic design of a spiral wound element and SEM view of feed spacer.
spacer used in CPA5 has 16% less pressure drop operating at 25 lmh (15 gfd) and 80% recovery
than an element made with standard 34 mil spacer. at 25°C, will have about 2.6 bar of pressure drop
As a result, these new 37.2 m2 (400 sq) ele- with a CPA3 element using 0.66 mm feed spacer.
ments can save additional energy. In a two-stage For CPA3-LD, this would be 1.6 bar (39% less)
brackish RO system, the pressure drop will be
about 2–3 bar. For example, a two stage system
100
Stnd 26 mil
90
New 31 mil
CPA3
80 New 34 mil
3.5 Stnd 34
Pressure drop (kPa)
2.5
50
2.0 CPA3-LD
40 Conventional
1.5
30 CPA5
1.0
20
0.5
10
0.0
0
3
04
04
05
-0
l-0
-0
-0
-0
l-0
-0
n-
p-
n-
ay
ar
ar
ay
ov
ov
Ju
Ju
Se
Ja
Ja
M
M
M
M
N
3-
3-
3-
3-
3-
3-
3-
3-
3-
3-
Fig. 9. Pressure drop in a NF system operating on low Fig. 10. Pressure drop as a function of feed flow rate
turbidity feed water. measured for 4 different spiral wound elements.
214 C. Bartels et al. / Desalination 221 (2008) 207–214
5. Conclusion
Delta-pressure of 1st stage (bar)
4 CIP
28 mil The spiral wound element design improve-
CIP
CIP
CIP ments described here will ensure that the ele-
3
CIP
ments maintain good physical integrity over a long
period of time and will also reduce the operating
2
31 mil cost. The added feature of vents provided in the
CIP new seal carrier designs will ensure that air can
1
34 mil
be readily removed from the annular gap between
0
0 30 60 90 120 150 180 210 240 270 the outside of the element and the pressure vessel
Operation period (days) wall. This ensures rapid pressure equalization
Fig. 11. Comparison of element performance on surface between the inside and outside of the spiral
water feed using different feed spacer thicknesses. element. As a result, aggressive operation will be
much less likely to cause damage, such as bursting
of the FRP shell.
and 1.3 bar (49% less) for CPA5. Again more The new, thicker brine spacers will be advanta-
importantly for poor feedwater quality, these geous for more consistent operation when treat-
elements will not have channel plugging as rap- ing poor quality feedwaters. The lower pressure
idly, and are more readily cleaned. As evidence drop will reduce cleaning frequency, allow clean-
of this, Fig. 11 shows the performance of a RO ing to be more effective, and reduce the potential
system running on surface water feed. The for element damage caused by high dP. Due to
operation was done in three phases, first with a improved automation, these new brine spacers can
standard 0.71 mm (28 mil) spacer, then a new be implemented without reducing membrane
geometry 0.79 (31 mil) spacer, and finally the surface area.
new geometry 0.86 (34 mil) spacer. The most
stable operation was achieved with the last 2 types,
and the lowest dP was achieved with the 34 mil Reference
spacer. It is also seen that the conventional [1] J. Schwinge, D.E. Neal, Wiley, D.F. Fletcher and
0.71 mm spacer element has numerous clean-in- A.G. Fane, Spiral wound modules and spacers,
place (CIP) events to maintain the acceptable review and analysis, J. Membr. Sci., 242 (2004)
pressure drop in the vessel. 129–153.