Sie sind auf Seite 1von 12

OP-300

TECHNICAL DATA

Construction Semiautomatic microprocessor controlled desktop instrument


Display 40 characters alfanumeric LCD with lighting
Display ranges pH pX Concentration mV temperature
0.000 ... 14.000 0.000 ... 7.000 max. 4 digits -2000 .. +2000 0.0 ... 100.0 °C
(0.0001...9999)

Resolution pH pX Concentration mV temperature


0.001 0.001 0.0001 0.1 0.1 °C
Accuracy --- Abs. mV temperature
± 0.1% ± 0.2mV 0.5 °C
Inputs 1+1 pcs. potentiometric inputs (sensor + reference electrodes: ‘’BNC’’ type)
1 pc. temperature sensor (‘’BNC’’ type)
1 pc. for automatic measurement start (pair of banana)
Outputs 1 pc. serial port (9p. DSUB, EIA-232 type)
1 pc. analogue for registrator (± 2V: min. 1 kΩ: pair of banana)

Power supply AC 220 -230 V; 50/60 Hz; max. 20 VA CE


Working temperature range + 10 ... + 35 oC

Storing temperature range 0 ... + 50 oC

Protection IP20
Classification I. danger class
(according to MSZ EN II. overflow group
61010-1/1994) 2. polution class

Dimensions 300 x 220 x 120 mm


Material of the box ABS
Mass Appr. 1.8 kg
OP-211
TECHNICAL DATA

Construction Universal, desktop, digital instrument for electroanalytical


measurements

Display 3.5 digit, LCD

Display ranges pX mV
0.00 ... 14.00 -1999 .. +1999

Resolution 0.01 pX 1 mV

Reproducibility 0.02 pX ± 2 mV (REL. mV)


Accuracy ± 0.5 % (ABS. mV)

Connectors 1 pc. ‘’BNC’’ type for sensors or combination electrode


1 pc. ‘’BNC’’ type for reference electrode

Power supply AC 220-230 V; 50/60 Hz

Working temperature range


+ 10 ... + 50 oC
Storing temperature range
-10 ... + 70 oC

Classification MSZ EN 61010-1/1994


III./B class MSZ 171/1-1984 CE

Protection IP40 MSZ IEC 529

Dimensions 290 x 220 x 100 mm


Materail of the box ABS
Mass Appr. 1.3 kg
OP-2000
TECHNICAL DATA

Construction Semiautomatic, microprocessor controlled, desktop instrument


Display by IBM compatible PC with Microsoft Windows
Display ranges pH pX Concentration mV Temperature
0.000 ... 14.000 0.000 ... 7.000 max. 4 digits -2000 .. +2000 0.0 ... 80.0 °C
(0.0001...9999)

Resolution pH pX Concentration mV Temperature


0.001 0.001 0.0001 0.1 0.1 °C
Reproducibility ---- Abs. mV Temperature
± 0.1% ± 0.2mV 0.5 °C
Connectors 1+1 pcs. portentiometric input (sensor + reference electrode: ‘’BNC’’ type)
1 pc. for temperature sensor (‘’BNC’’ type)

Output 1pc. serial port (9p. DSUB, EIA-232 type)

Power supply AC 220 -230 V; 50/60 Hz; max. 6 VA CE


Working temperature
range + 10 ... + 35 oC
Storing temperature range 0 ... + 50 oC
Protection IP 20
Dimensions 240 x 180 x 70 mm
Material of the box ABS
Mass Appr. 0.8 kg
OP-116
TECHNICAL DATA

Construction Desktop, digital instrument

Display 3.5 digit, LCD

Display range 0.00 ... 14.00 pH

Resolution 0.01 pH

Reproducibility 0.02 pH

Connectors 1 pc. ‘’BNC’’ type for ion-selective, pH or combination electrode


1 pc. ‘’BNC’’ type for reference electrode

Power supply AC 220-230 V; 50/60 Hz

Working temperatur range + 10 ... + 50 oC

Storing temperature range -10 ... + 70 oC

Classification MSZ EN 61010-1/1994


III./B class MSZ 171/1-1984 CE
Protection IP40 MSZ IEC 529

Dimensions 290 x 220 x 100 mm


Material of the box ABS
Mass Appr. 1.3 kg
OP-115
TECHNICAL DATA

Construction Portable, digital instrument

Display 3.5 digit, LCD

Measurement range 0.00 ... 14.00 pH

Resolution 0.01 pH

Accuracy 0.02 pH

Connector 1 pc. for combination electrode

Power supply + 8.5 V ... 15 V direct current ( protected against invers polarity)
(1 db 6F22 battery, minimum 200 working hours)

Working temperature range + 10 ... + 50 oC

Storing temperature range -10 ... + 70 oC

Classigication MSZ EN 61010-1/1994


III./B class MSZ 171/1-1984
Protection IP20 MSZ IEC 529

Dimensions 230 x 60 x 65 mm
Material of the box ABS
Mass Appr. 0.5 kg
OP-113
TECHNICAL DATA

Construction Portable, digital insrument

Display 3.5 digit, LCD

Display ranges 0.00 ... 14.00 pH ; 0.00 ... 8.00 pX

Resolution 0.01 pH ; 0.01 pX

Reproducibility 0.02 pH ; 0.02 pX

Connectors 1 pc. for pH, ion-selective or combination electrode


1 pc. for reference electrode

Power supply + 8.5 V ... 15 V direct current ( protected against inverse polarity )
(1 pc. 6F22 battery, minimum 200 working hours)

Working temperature range + 10 ... + 50 oC

Storing temperature range -10 ... + 70 oC

Classification MSZ EN 61010-1/1994


III./B class MSZ 171/1-1984
Protection IP20 MSZ IEC 529

Dimensions 230 x 60 x 65 mm
Materinal of the box ABS
Mass appr. 0.5 kg
OP-110
TECHNICAL DATA

Construction Portable, digital instrument

Display 3.5 digit, LCD

Output range 0.00 ... 14.00 pH

Resolution 0.01 pH

Reproducibility 0.02 pH

Connectors 1 pc. for pH or combination pH electrode


1 pc. for reference elecrode

Power supply + 8.5 V ... 15 V direct current ( protected against invers polarity )
(1 pc 6F22 battery, minimum 200 working hours)

Working temperature range


+ 10 ... + 50 oC

Storing tempearture range -10 ... + 70 oC

Classification MSZ EN 61010-1/1994


III./B class MSZ 171/1-1984
Protection IP20 MSZ IEC 529

Dimensions 230 x 60 x 65 mm
Material of the box ABS
Mass Appr. 0.5 kg
OK-117
TECHNICAL DATA

Construction Universal, desktop, digital instrument for electroanalitical


instruments

Display 3.5 digit, LCD

pH Conductometry

Display range 0.00 ... 14.00 199.9 µS


1.999 mS
19.99 mS
Measurement signal -- ≅ 400 Hz square, 100 mV ‘’pp’’
Cell constant range -- 0.5 ... 1.3 cm-1
Resolution 0.01 pH 0.05 %
Reproducibility 0.02 pH ± 1 % (ref. to display randge)

Connectors 1 pc. ‘’BNC’’ type for sensor electrode


1 pc. ‘’BNC’’ type for reference electrode
1 pc. ‘’BNC’’ type for conductometric electrode

Power supply AC 220-230 V; 50/60 Hz

Working temperature range + 10 ... + 50 oC

Storing temperature range - 10 ... + 70 oC

Classification MSZ EN 61010-1/1994


III./B class MSZ 171/1-1984 CE

Protection IP40 MSZ IEC 529

Dimensions 290 x 220 x 100 mm


Material of box ABS
Mass Appr. 0.5 kg
OK-114
TECHNICAL DATA

Construction Universal, desktop, digital instrument

Display ranges Measurement frequencies


Measurement ranges 0 ... 19.99 µS 92.2 Hz
0 ... 199.9 µS 922 Hz
0 ... 1999 µS 4.6 kHz
0 ... 19.99 mS 4.6 kHz
0 ... 199.9 mS 13.1 kHz
0 ... 1999 mS 18.4 kHz
Accuracy ± 0.5 % of measured value ± 2 digit ( when C= 1.000 1/cm )
Cell constant range 0.080 ... 12.00 1/cm
Automatic temperature 0 ... 100 °C
compensation
Manual temperature 0 ... 100 °C
compensation
Temperature coefficient 0 ... 4.00 %/K
range
Temperature range - 5.0 ... 105.0 °C
Connector 1 pc. ‘’BNC’’ type for conductometric electrode
Output 2 pcs. banana 0 ... 2 V ( min. 1 kΩ ) for registrator
RS 232 C
Pover supply AC 220 -230 V; 50/60 Hz; max. 25 VA CE

Measurement temperature
range + 10 ... + 40 oC
Reference temperature 23 ± 2 oC
range
Storing temperature range -10 ... + 50 oC

Classification I. class MSZ 171/1-1984


Protection IP20 MSZ IEC 529

Dimensions 315 x 252 x 110 mm


Mass appr. 4 kg
OK-113
TECHNICAL DATA

Construction Portable digital insrument for measurements on field

Display 3.5 digit, LCD

Display ranges 199.9 µS


1.999 mS
19.99 mS
Measurement signal ≅ 400 Hz square, 100 mV ‘’pp’’
Cell constant range 0.3 ... 3.0 cm-1
Resolution 0.05 %
Reproducibility ± 1 % (relative to display range)

Connectors 1 pc. for conductometric electrode

Power supply 9 V ( 1 db 6F22 battery ), max. 7 mA

Working temperature range


+ 10 ... + 50 oC
Soring temperature range -10 ... + 70 oC

Classification MSZ EN 61010-1/1994


III./B class MSZ 171/1-1984

Protection IP40 MSZ IEC 529

Dimensions 290 x 220 x 100 mm


Material of the box ABS
Mass Appr. 0.3 kg
OK-112
TECHNICAL DATA

Construction Universal desktop analogue instrument for electroanalytical


measurements

Display ranges Measurement frequencies


Measurement ranges 0 ... 1 µS 230 Hz
0 ... 3 µS 230 Hz
0 ... 10 µS 1,1 kHz
0 ... 30 µS 1,1 kHz
0 ... 100 µS 1,1 kHz
0 ... 300 µS 5,6 kHz
0 ... 1 mS 5,6 kHz
0 ... 3 mS 5,6 kHz
0 ... 10 mS 11 kHz
0 ... 30 mS 11 kHz
0 ... 100 mS 11 kHz
0 ... 300 mS 15,6 kHz
0 ... 1 S 15,6 kHz
Accuracy ± 1.5 % (relative to display range)
Reproducibility ±1%

Connector 1 pc. ‘’BNC’’ type for conductometric electrode


Output 2 pc. banana connector 0...1 V ( min. 1 kΩ ) to registrator
Power supply AC 220 -230 V; 50/60 Hz; max. 6 VA CE

Ambient temperature range + 10 ... + 40 oC


for measurements
Reference temperature 23 ± 2 oC
range
Storing temperature range -10 ... + 50 oC

Classification I. class MSZ 171/1-1984

Protection IP20 MSZ IEC 529

Dimensions 280 x 180 x 160 mm


Mass Appr. 3,5 kg
OH -113
TECHNICAL DATA

Construction Portable, digital amperometric instrument

Display 3.5 digit, LCD

Measurement range 0 ... 199 relative % ( referred to air saturation )

Measurement accuracy ± 1 % referred to the measurement limit, ± 1 digit if the


measurement ferformed at the temperature of calibration; ± 2 %
if the temperature changes by max. ± 15 °C as referred to
calibration temperature between + 5 ... + 35 °C

Pressure correction 800 ... 1050 mbar ( manual )

Temperature measurement 0 ... + 50 °C

Measurement accuracy ± 0.5 °C ± 1 digit

Connectors 1 pc: for RA-0950 P dissoloved oxygen electrode


1 pc: for the temperature

Power supply + 8.5 V ... 15 V direct current (1 pc 6F22 battery)

Measurement temperature
range + 10 ... + 50 oC

Storing temperature range


-10 ... + 70 oC

Classification MSZ EN 61010-1/1994


III./B é. v. osztály MSZ 171/1-1984
Protection IP20 MSZ IEC 529

Dimensions 230 x 60 x 65 mm
Material of the box ABS
Mass Appr. 0,5 kg