The document compares the costs of using a baby boiler versus an electric heater to heat water. It provides specifications for the volume of water, temperatures, heat required, fuel requirements, and costs for each option. The baby boiler uses fuel which costs 11,950 IDR per liter, while the electric heater uses electricity which costs 996.74 IDR per kWh. Based on the calculations, using a baby boiler would save 183,392,410 IDR per year for heating 20 cubic meters of water per hour, and would save 3,025,974,757 IDR per year for heating 30 cubic meters of water per hour compared to using an electric heater.
The document compares the costs of using a baby boiler versus an electric heater to heat water. It provides specifications for the volume of water, temperatures, heat required, fuel requirements, and costs for each option. The baby boiler uses fuel which costs 11,950 IDR per liter, while the electric heater uses electricity which costs 996.74 IDR per kWh. Based on the calculations, using a baby boiler would save 183,392,410 IDR per year for heating 20 cubic meters of water per hour, and would save 3,025,974,757 IDR per year for heating 30 cubic meters of water per hour compared to using an electric heater.
The document compares the costs of using a baby boiler versus an electric heater to heat water. It provides specifications for the volume of water, temperatures, heat required, fuel requirements, and costs for each option. The baby boiler uses fuel which costs 11,950 IDR per liter, while the electric heater uses electricity which costs 996.74 IDR per kWh. Based on the calculations, using a baby boiler would save 183,392,410 IDR per year for heating 20 cubic meters of water per hour, and would save 3,025,974,757 IDR per year for heating 30 cubic meters of water per hour compared to using an electric heater.
Initial Temperature of water T1 75.0 C 348.0 K Density of water ρ 971.8 Kg/m3 Heat Capacity of water Cp 4.2 Kj/Kg Final Temperature of water T2 80.0 C 353.0 K Mass of water m 19436.0 Kg/h Heat Required Q 407718.7 Kj/h 113.3 Kw/h
Enthalpy steam @ 4 Barg ΔH 2748.6 Kj/kg
Temperature steam @4 Barg Ts 151.9 C 424.9 K Temperature Raw Water Tw 25.0 C 298.0 K Required steam flow 148.3 Kg/h Heat Capacity of water Cp 4.2 Kj/Kg Heat Required 78968.7 Kj
Fuel Caloric Value 45217.0 Kj/kg
Fuel Required 1.7 Kg 2.3 Kg Fuel Density 0.8 Kg/L Volume fuel consumption 2.8 Liter
Tarif listrik IDR 996.74 per Kwh
Total biaya IDR 112,887 per hour IDR 260,091,378 per year
Harga Fuel IDR 11,950 per liter
Total biaya IDR 33,289 per hour IDR 76,698,969 per year
SAVING IDR 183,392,410 per year
BABY BOILER VS ELECTRIC HEATER
Volume of water V 30.0 m3/h
Initial Temperature of water T1 25.0 C 298.0 K Density of water ρ 971.8 Kg/m3 Heat Capacity of water Cp 4.2 Kj/Kg Final Temperature of water T2 80.0 C 353.0 K Mass of water m 29154.0 Kg/h Heat Required Q 6727358.4 Kj/h 1868.7 Kw/h
Enthalpy steam @ 4 Barg ΔH 2748.6 Kj/kg
Temperature steam @4 Barg Ts 151.9 C 424.9 K Temperature Raw Water Tw 25.0 C 298.0 K Required steam flow 2447.5 Kg/h Heat Capacity of water Cp 4.2 Kj/Kg Heat Required 1302984.0 Kj
Fuel Caloric Value 45217.0 Kj/kg
Fuel Required 28.8 Kg 37.5 Kg Fuel Density 0.8 Kg/L Volume fuel consumption 46.0 Liter
Tarif listrik IDR 996.74 per Kwh
Total biaya IDR 1,862,634 per hour IDR 4,291,507,738 per year
Harga Fuel IDR 11,950 per liter
Total biaya IDR 549,276 per hour IDR 1,265,532,980 per year