OJ Microline®

OCC2

T H E R M O S TAT S F O R U N D E R F L O O R H E AT I N G

4-event Clock Thermostat


Recommended for control of heating PRODUCT PROGRAMME
Systems for heating comfort with minimum WHITE COLOUR PRODUCT

power consumption. OCC2-1991H1 OCC2-1991-E2 Clock thermostat incl. Floor sensor 3m


OCC2-1999H1 OCC2-1999-E2 Clock thermostat with built-in room sensor

• On/off control up to 3,600W, 16A. ACCESSORIES

ETF-944/99-H White remote room sensor for surface wall mounting


• Built-in clock function for automatic Used together with OCC2-1991H1
comfort and setback temperature. OTN-VH White base plate for surface wall mounting
ACC-001 White backing plate 86x86 mm for large wall sockets (10 pcs.)
• Set only time and day at installation. ACC-003-D6 Graphite front cover
ACC-004-B5 Aluminium frame
Delivered with factory-set program.
• With built-in 2-pole interrupter for
Thermostat control
convenient switching off at airing the
Electronic on/off thermostat for control of temperature by
room and at summer times. means of a sensor either placed externally or built into the
• Adaptive control ensuring comfort thermostat. The heating output is switched on and off with a
temperature at the required time. differential of only 0.4ºC.
• Inclined backlit display for better Housing IP21
read-out. Can be mounted in bathrooms and other humid rooms.
• Flush mounting in a standard wall socket.
• Snap mounting of front cover for easy Built-in clock function
OCC2 is with built-in 4-event program for automatic comfort
installation.
and setback temperature.

Elegant European design


Can be mounted in combination with various
types of light switches.

© 2008 OJ Electronics A/S


OJ ELECTRONICS A/S T. +45 73 12 13 14
STENAGER 13B F. +45 73 12 13 13
DK-6400 SØNDERBORG OJ@OJ.DK
DENMARK WWW.OJ.DK

BR929A03

BR929A05
1 2 3 4 5 6

L N MAX 16A SENSOR


230VAC 3600W

28 20
48

Dimensions (mm) Dimensions (mm) Connections

Monitoring of energy consumption Backup function


Total switch-on time in percentage can be read out within All settings and the clock are maintained in case the
the latest 2 days, 30 days or 365 days. In this way the thermostat is switched off on the built-in interrupter.
heating consumption can be controlled. In case the main power supply is interrupted for more than
50 hours the current time and date must be adjusted.
Factory-set of events In power term installations with daily disconnection of the
The OCC2 is delivered with factory-set programs as follows: main power to the heating installation, it is recommended to
connect the thermostat to the primary line that is not
DAY 1-5
disconnected, and connect the heating installation over an
EVENT TIME TEMPERATURE W/FLOOR SENSOR W/ROOM SENSOR
external relay.

3.1.3-01.08-OCC2-GB · Subject to alterations · ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S
1 06:00-08:00 Comfort 25˚C 20˚C
2 08:00-16:00 Setback 20˚C 15˚C
3 16:00-22:30 Comfort 27˚C 22˚C Read-out of sensor temperature
4 22:30-06:00 Setback 20˚C 15˚C The actual temperature of the floor sensor can be read out.
DAY 6-7

EVENT TIME TEMPERATURE W/FLOOR SENSOR W/ROOM SENSOR

1 08:00-23:00 Comfort 27˚C 22˚C


4 23:00-08:00 Setback 20˚C 15˚C
TECHNICAL DATA

Supple voltage 230V AC ±15% 50/60Hz


Output relay SPST 16A, 3,600W resistive load or
Individual programming of events:
1A inductive load
The factory-set periods and/or temperatures can be
Built-in interrupter 2-pole, 16A
changed according to requirement.
Temperature range +5/+40˚C
Furthermore, the following programs can be selected:
Limitation of range Min./max.
• 4 events 6 days and 2 events day 7
Clock function 4-event program
• 4 events per day
Ambient temperature 0/+40°C during operation
On/off differential 0.4°C
OCC2 is with adaptive function meaning the thermostat
Housing IP21
calculates when the heating has to be switched on to make
Sensor type NTC
sure that the comfort temperature is obtained at the
Dimensions (H/W/D) 80/80/48 mm
required time. Size of display (H/W) 25/22 mm

Comfort mode
The temperature can be temporarily changed for a single
event. The comfort mode temperature is reset at the next
event, and the thermostat will return to the scheduled event
program.

Manual mode
The scheduled event program can be cancelled e.g. during
holidays, instead the temperature can be adjusted to e.g.
5˚C for frost protection. The new setpoint is valid until the
manual mode is cancelled.

© 2008 OJ Electronics A/S