Beruflich Dokumente
Kultur Dokumente
Supported model
Trinitron
KV-20S90 RM-Y155
9-965-905-01
KV-20S90 / 21SE43C
SERVICE HSIZ 0
MUTING POWER
(Enter into (Service Mode)
memory)
DISPLAY
3
2. Press 1 or 4 on the Remote Commander to select the item. (Service Mode)
Item (Data up)
3. Press 3 or 6 on the Remote Commander to change the data.
1
4. Press MUTING then ENTER to write into memory. Disp. (Item up) 6
Item (Data down)
SERVICE ADJUSTMENT MODE MEMORY 2
(Device Item Up) 5
(Device item down)
Mode
4 ENTER
MUTING Green
Disp. (Item down) (Enter into
SERVICE WRITE
memory)
8
ENTER Red (Initialize) 0
(Remove from
memory)
1. Press 8 then ENTER on the Remote Commander to initialize. VOLUME (+)
(Service Mode)
Mode
— 16 —
KV-20S90 / 21SE43C
ADJUSTMENT ITEMS (1 OF 2)
ADJUSTMENT ITEMS (2 OF 2)
DATA INITIAL AVERAGE
Reg # ITEM FUNCTION RANGE DATA VIDEO DATA
52 FSC G Output On/Off 0,1 0 1
53 K-ID B Output On/Off 0,1 0 0
54 HOSC Horizontal VCO Oscillation Freq. 0-15 10 7
55 VSS Vertical Sync Slice Level 0,1 0 0
56 HSS Horizontal Sync Slice Level 0,1 0 0
57 HMSK HMASK On/Off 0,1 1 1
58 VTMS Select Signal VTIM Pin 0-3 0 0
59 CDMD Vertical Count Down Mode Switching 0-3 3 3 **
60 AFC AFC Loop Gain Switching 0-3 0 0 *
61 FIFR Field Frequency 0-3 3 3
62 SBAS Sub Bass 0-15 8 8
63 STRE Sub Treble 0-15 9 9
64 SBAL Sub Balance 0-15 13 13
65 DISP O.S.D Display Position 0-127 15 5
66 PADJ POWER ADJUSTMENT 0-63 51 42
67 HCHM H SYNCH SEP. LIMIT FOR TUNER 0-127 69 69
68 HCLM H SYNCH SEP. LIMIT FOR TUNER 0-127 16 16
69 HCHS H SYNCH SEP. LIMIT FOR VIDEO 0-127 69 69
70 HCLS H SYNCH SEP. LIMIT FOR VIDEO 0-127 16 16
71 ID0 0-255 SEE ID MAP
72 ID1 0-255 SEE ID MAP
73 ID2 0-255 SEE ID MAP
74 ID3 0-255 SEE ID MAP
75 ID4 0-255 SEE ID MAP
76 ID5 0-255 SEE ID MAP
77 ID6 0-255 SEE ID MAP
78 ID7 0-255 SEE ID MAP
* = TV/VIDEO = 0
** = TV = 0, VIDEO = 1
Mode Function Data
Notes:
No. 1-78 show the order that each adjustment mode may be selected while in Service Mode.
Data Range shows the range of possible setting for each Adjustment Mode. SERVICE ID0 25
Initial Data shows the standard settings for each Adjustment Mode.
ID MAP
Model Destination ID-0 ID-1 ID-2 ID-3 ID-4 ID-5 ID-6 ID-7
KV-20S90 US 25 3 1 227 3 1 0 0
KV-21SE43C E 17 3 1 195 115 1 0 0
— 18 —
KV-20S90 / 21SE43C
V. FREQUENCY CHECK
DISPLAY POSITION ADJUSTMENT (DISP)
1. Select video 1 with no signal input.
2. Set the conditions for a standard setting. 1. Input a color-bar signal.
3. Connect the frequency counter to TP-508 or CN501 pin 6 (V DY+) 2. Set to Service Adjustment Mode.
connector and ground. 3. Select DISP with 1 and 4 .
4. Check that V. Frequency shows 60 ± 4 Hz. 4. Adjust values of DISP with 3 and 6 to adjust characters to the center.
5. Write to memory by pressing MUTING then ENTER .
SUB CONTRAST ADJUSTMENT (RDRV) 6. Check to see if the text is displayed on the screen.
6. Connect an oscilloscope probe to CN301 pin 2 (Red Out) and SUB HUE, SUB COLOR ADJUSTMENT (SHUE,
ground . SCOL)
7. Select RDRV with 1 and 4 .
1. Input a color-bar signal.
8. Adjust the value of RDRV with 3 and 6 for
2. Set to Service Adjustment Mode.
1.50 ± 0.05 Vpp.
3. Connect a probe to TP47B B-OUT (C Board).
4. Measure white V1 and blue V4.
White 4.1) Increase SCOL Register +1 setp.
V1 V2 V3 V4
Black STANDARD
|V4 - V1| = ± 0.2Vpp
|V3 - V2| = ± 0.2Vpp
9. Reset the item DCOL to 1.
10. Press MUTING then ENTER to save into the memory.
11. Return the following back to normal after adjustment.
5. Press MUTING then ENTER to save into the memory.
PICTURE: MAX
COLOR: CENTER
BRIGHT: CENTER
R ON: ON (1)
G ON: OFF (1)
B ON: OFF (1)
— 19 —
KV-20S90 / 21SE43C
Green
SERVICE READ
0
Red
ENTER
V LINEARITY (VLIN)
V CORRECTION
— 20 —