DESIGN CALCULATIONS FOR BOTTOM RAFT

Bottom of raft @ E.L = 215.4 m


F.G.L = 218 m
Water table @ E.L = 218 m
Upward pressure = 26 kN/M^2
Thk of Raft = 600 mm
clear cover for raft = 75
self wtof slab = 15 kN/M^2
Net upward Pressure (p) = 11 kN/M^2
Length of Raft = 18 m
Width of Raft = 5.6 m
Projection length = 0.5 m
W.T from Top of raft(H2) = 3.2 m
Wall thk = 0.3 m
slab thk = 0 m
W1(wt of wall+slab)/m = 24 kN/M
W2( retained soil) = 28.8 kN/M
gsat of soil = 21 kN/M^2
Ka = 0.333
Pa = 69.955 kN/M
B.M at edge of cantlvr = 113.49 kNm

Net unbalanced force = -26.4


B.M at center of span = 139.36
scbc = 8.5
sst = 150
m = 10.98
k = 0.3836
j = 0.8721
Ast top = 2029
bar dia = 20
spg = 154.83
Astprovided on Top = 20TOR @154
Ast bottom = 1652.4
bar dia = 20
spg = 190.13
Astprovided on bottom = 20TOR @190

Longitudinal steel = 0.1571 distribution steel as per IS3370


(combined 2faces)
Minimum dist steel = 0.12 As per IS 456
Area of steel = 720
bar dia = 10
spg = 109.08
Astprovided in = 10TOR @109
longitudinal Direction

Check for Floatation:


Uplift on Bottom of Slab: = 26 KN/m2
Base dimension of raft:
L = 18 m
B = 5.6 m
Thk = 0.6 m
Rl of wall top = 218.3 m
Heigth of wall above raft top = 2.3 m
a)Total upward floatation force: = 2620.8 KN B= 5.6
X
0.5
b) Calculation of downward force:

i) Weight of wall = 814.2 kN 7.2


ii) Weight of raft = 2116.8 KN
iii) Weight of roof = 0 KN
2931 KN b

Check for Ratio = 1.12


Safe against uplift