Stack Exhaust Concentration

Stack Height B‐1 B‐2 B‐3 Velocity Temperature Mass Flow (no background)


(ft) (lb/hr) (lb/hr) (lb/hr) (ft/sec) (F) (klb/hr) (ug/m3) Note
Three boilers at 9.9lb/hr, 40" stacks
215 (65m) 9.9 9.9 9.9 56 304 30 42 Base run
200 9.9 9.9 9.9 56 304 30 76 Decreased stack
185 9.9 9.9 9.9 56 304 30 95 Decreased stack
175 9.9 9.9 9.9 56 304 30 133 Decreased stack
Two boilers at 9.9lb/hr, 40" stacks
185 9.9 9.9 0 56 304 30 74 Base run
175 9.9 9.9 0 56 304 30 96 Decreased stack
150 9.9 9.9 0 56 304 30 130 Decreased stack
One boiler at 9.9 lb/hr, 40" stack
125 9.9 0 0 56 304 30 87 Base run
Three boilers at 6 lb/hr, 40" stacks
125 6 6 6 56 304 30 140 Base run
125 6 6 6 56 304 30 137 Grid adjustment
125 6 6 6 56 304 30 141 Boundary around tight plant building
125 6 6 6 56 304 30 141 Boundary around plant property
Three boilers at 9.9 lb/hr, 36" stacks
175 9.9 9.9 9.9 70 304 30 127 Base run
185 9.9 9.9 9.9 70 304 30 91 Increased stack
Three boilers at 6 lb/hr, 30" stacks
125 6 6 6 100 304 30 132 Base run high velocity
125 6 6 6 100 315 30 127 Increased exhaust temp
125 6 6 6 100 304 50 104 Increased exhaust flow
Three boilers at 6 lb/hr, 36" stacks
55 6 6 6 70 304 30 264 Base run
75 6 6 6 70 304 30 235 Increased stack
125 6 6 6 70 304 30 137 Increased stack
150 6 6 6 70 304 30 111 Increased stack
160 6 6 6 70 304 30 97 Increased stack
175 6 6 6 70 304 30 76 Increased stack
Two boilers at 6 lb/hr, 36" stacks
125 6 6 0 70 304 30 94 Base run
Three boilers, 36" stacks, find emission rate for compliance with 75' stacks
75 2 2 2 70 304 30 78 Base run
75 2.5 2.5 2.5 70 304 30 98 Increased emission rate
75 3 3 3 70 304 30 117 Increased emission rate
FYI, Three boiler on GAS ‐ 0.04 lb/MMBtu (3.54 lb/hr), 36" stacks 
75 3.9 3.9 3.9 70 304 30 152 Base run
100 3.9 3.9 3.9 70 304 30 126 Increased stack
125 3.9 3.9 3.9 70 304 30 89 Increased stack
Note:  40" stacks were run before vendor indicated 36" stacks would be typical.

Three boilers at 9.9 lb/hr, 30" stacks
150 9.9 9.9 9.9 100 304 30 164 Base run
175 9.9 9.9 9.9 100 304 30 109 Increased stack
180 9.9 9.9 9.9 100 304 30 89 Increased stack
Three boilers at 6 lb/hr, 30" stacks
125 6 6 6 100 304 30 132 Base run
150 6 6 6 100 304 30 100 Increased stack
FYI, Three boiler on GAS ‐ 0.04 lb/MMBtu (3.9 lb/hr), 30" stacks 
100 3.9 3.9 3.9 100 304 30 123 Base run
110 3.9 3.9 3.9 100 304 30 105 Increased stack
115 3.9 3.9 3.9 100 304 30 98.5 Increased stack
125 3.9 3.9 3.9 100 304 30 87 Increased stack