Technical Information

IdentifyIR™
CUSTOMIZED FOR SYNTHETIC ORGANIC
CHEMISTRY APPLICATIONS

IdentifyIR is a rugged, IdentifyIR uses a diamond


Feature Highlights miniaturized FT-IR (Fourier attenuated total reflection
Transform Infrared) analysis (DATR) sampling interface, which
ǩ Near-real-time reaction analysis system that is fast, easy-to- means it can rapidly analyze
and unknown identification use, and accurate. Designed any solid or liquid sample,
ǩ Easily move from the bench to fume hood, specifically for tasks performed including caustic and corrosive
production floor or loading dock by organic chemists and materials. The integrated 100x
ǩ Small footprint chemical engineers, its video microscope facilitates
ǩ No sample preparation ChemAssist software takes the both spectral and visual
ǩ Results in seconds mystery out of IR analysis – it is characterization of solid forms.
ǩ Simple operation like having a team of IR experts Video images and infrared
ǩ 100x video maginification by your side. spectra are linked for rapid
screening of polymorphs and
IdentifyIR’s small footprint solvates.
(only 7” x 15”), sturdy all-metal
construction, and seal housing IdentifyIR and ChemAssist
makes it ideal for use in the hood together provide rapid results
or on the bench. for faster decision making.

Continued overleaf

www.smithsdetection.com
IdentifyIR
Rapid Results for Optimizing Or- ǩ 2 SWLFDOSHUIRUPDQFH The heart of ChemAssist is
ganic Chemistry provides state-of-the-art a proprietary database of USA
ǩ Reaction spot-checking and accuracy and precision. molecular functional groups and
Scientific Division/Service
Smiths Detection Inc.
end-point analysis ǩ 3DWKOHQJWKVHOHFWLRQSDWK their characteristic IR absorption 21 Commerce Dr.
ǩ Solid form screening length (i.e., the number frequencies. Specialized Danbury, CT 06810
ǩ Reaction profiling T: +1 203 207 9700
of reflections through algorithms within ChemAssist F: +1 203 207 9780
ǩ Compound identification the diamond crystal) can use this database, along with Toll-free: 1 888 473 6747
and verficiation be selected to match the molecular structures entered by danbury@smithsdetection.com
ǩ And much more... application requirements. the user, to automatically create Civil Market
an optimized set of IR absorption Smiths Detection Inc.
Diamond ATR (DATR) ChemAssist Software 30 Hook Mountain Rd.
bands that can be used, for PO Box 410
DATR sampling interface offers ChemAssist instrument control example, to measure chemical Pine Brook, NJ 07058
several advantages: and data analysis software T: +1 973 830 2100
changes. In addition, ChemAssist
ǩ 5XJJHGGLDPRQGLV eliminates the need for IR F: +1 973 830 2200
can identify the presence of USinfo@smithsdetection.com
impervious to organics, spectroscopy expertise to functional groups based on a
acids, bases, reducing and obtain accurate and valuable US Military Market
sample’s IR spectrum-whether
oxidizing agents, and solids information about the user’s
Smiths Detection Inc.
the user is tracking a reaction 2202 Lakeside Blvd.
pressed against it to ensure materials and reactions. in progress or analyzing an Edgewood, MD 21040
proper contact cannot T: +1 410 510 9100
unknown. ChemAssist makes IR F: +1 410 510 9491
scratch it. This easy-to-learn and easy- correlation tables a thing of the militaryus@smithsdetection.com
ǩ 9HUVDWLOHFDQKDQGOH to-operate software includes past for the practicing chemist.
powders, solids, liquids, gels organic chemistry-specific task
and pastes in both organic modules for tracking chemical ChemAssist can also search International
and aqueous solvents changes, characterizing solid Germany
on-board spectral libraries to
ǩ (DV\FOHDQLQJVDPSOLQJ forms, and identifying and
Smiths Heimann GmbH
verify the identity of materials Im Herzen 4
surface cleans up in seconds verifying materials. and identify unknowns. These 65205 Wiesbaden
by wiping with ordinary T: +49 (0)611 9412 0
libraries can be customized F: +49 (0)611 9412 229
solvents, making it ready to Each task module features for the user’s own proprietary mail.germany@smiths-heimann.com
analyze the next sample with customizable, one-click report compounds.
virtually no delay. generation. UK
Smiths Detection International UK
459 Park Ave.

Technical Data
Bushey, Watford
Herts WD23 2BW
T: +44 (0) 1923 294400
F: +44 (0) 1923 294401
General Specifications uk@smiths-heimann.com
Input Power 100 – 240 VAC, 2.0 Amps max, 50-60 Hz, or 12VDC
Weight 22 lbs. (10 kg) France
Size 7” x 15” x 14” (18 cm x 39 cm x 36 cm) Smiths Heimann S.A.S.
Range 4000 to 650 cm 36, rue Charles Heller
Sample Size As small as 5 µL or 100 µm 94400 Vitry sur Seine
Sample Interface DATR and other options T: +33 (0)1 55 53 55 55
F: +33 (0)1 46 80 34 99
User Interface Software customized for rapid sample identification
mail.france@smiths-heimann.com
Operating System Windows XP
Computer Interface USB 2.0 interface Canada
Integrated Video Microscopy System 100x Magnification with full color image display and capture Smiths Detection - Toronto Ltd.
7030 Century Avenue
Options Mississauga, Ontario
Solids & Liquids Configuration Canada L5N 2V8
Liquids-only Configuration T: +1 905 817 5990
F: +1 905 817 5992
1, 3, and 9 reflection DATR disks with heating and Hastelloy® options
Purgeable sampling cell Smiths Detection Montréal Inc.
Hardened shipping case 950 Bergar, Laval (Quebec)
Aldrich/Smiths Detection ATR Special Libraries Canada H7L 5A1
IChem STJapan ATR Spectral Library T: +1 (450) 967 0010
Smiths Detection ATR Libraries options F: +1 (450) 967 7444
mail.canada@smiths-heimann.com

Modifications reserved 95590845 09/14/2007 © Smiths Detection Inc.