REMOTE CONTROL PANEL ( RCP )

USER’S GUIDE

MODEL:PWM-Plus
General Security Warnings
1. Do not put any materials beside, around or on the rectifier that may block the inlets on the cover
and prevent its air circulation.
2. Do not put any flammable, burnable, combustible materials around the device.
3. Do not allow anybody to use the rectifier; only the appointed, authorized personnel must use.
4. Connection and installation of the device must be done by an authorized-qualified electrical technician.
5. In case of any fault or abnormal situation,do not interfere in the interior fittings of rectifier on your
own;switch off the device and call technical service or authorized dealer company.
6. This device was designed for only industrial usage with the aim of operating on the mains voltage
3-phase or 1-phase + earth. It is not suitable for indoor usage.
7. It can not be used as battery charger or electronic circuit feeding element.(The usage locations are
indicated in case special purpose manufacturing.)
8. The earth ground must be connected to the device body while making mains supply.The earth ground
must be put on the YELLOW-GREEN clips on the input panel or earth screw.
9. The rectifier’s mains cables must be chosen according to its input current. The cables which do not
have suitable thickness to this current may cause fire by warming. The aluminium lD plate on the
rectifier indicates I1 value which is the current that the device draws from mono phase.
10. In case of any damage for any reasons or any liqued has been spilled into the device, first switch off
it and turn off the power. Then immediately call the technical service.
11. Only original, appropriate components are allowed to use. Manufacturer is not responsible for any
damage occurred because of inappropriate or poor quality component usage.
12. Never open the doors of the running device and change input and output connections. If required,
First of all make sure of switching off the circuit breakers.
Installation
• When you deliverred your device, take off its package, then control it if there is any physical problem.
If you find any one, give prompt notice of the situation to the dealer company from which you have
bought the device before processing.
• Determination of the place for the rectifier; The rectifiers should be allocated far from corrosive
effects, in a dry, well-ventilated place where it can stand in balance. A well-ventilated place enhances
the efficiency of the rectifier.
• Preparing the rectifier for first operating; Before operating, check capacity of your mains voltage.Your
appliance was produced in accordance with 380V or 220V 50Hz AC voltage + earth. If there are
ripples at abnormal levels and decreases longer than %5 in your mains supply, please do not start
up the rectifier without making necessary adjustments. Your appliance has protective equipment
against over-current. If you have to, please choose an appropriate cable that is recommended by the
manufacturer.
• Read the instruction manual carefully before operating the rectifiers.The red busbar indicates (+)
pole and the black busbar (-) pole. Be careful and connect them tightly. Be attentive to any looseness
about busbars. Normally, remote unit cable is connected to terminals (RS485) on the power panel.
First, place the remote control unit on a suitable place for remote control connection. Then place
the cables where they are in safety against the crushings. After the last connection controls, start up
the rectifier. (For devices which have remote control unit).
• The rectifier consists of two main parts as device and remote control unit(RCU). During operating,
output voltage and current values can be changed on the panel without stopping the rectifier. Your
appliance will be ready to use if the power input connections are ready. As mentioned above, you
must follow these instructions if you are sure that there is no phase fault.
• For the first start, set the input fuse On state to operate the rectifier.
1 RS 485 Communication Link

Figure 1: Internal Structure of Remote Control and Device Communication Cable

1
2 Panel Image

Figure 2: Panel Image

• 1.POWER Led:Device power up.


• 2.LINE Led:All phases are suitable.Mains available.
• 3.THERM Led:Over-heat status.
• 4.ALARM Led:Failure status.
• 5.DISPLAY:With 4x20 characters LCD display.
• 6.ON/MODIFY Button:Starts the device while it is on the main screen. While on the settings screen,
saves adjusted value in the memory.
• 7.OFF/MENU Button:Stops the device while it is working.
• 8.AUTO Button and Led:
• 9.MANUAL Button and Led:Selects the value that is required to be changed on the settings screen.
• 10.VOLTAGE Button and Led:
• 11.AMPERE Button and Led:
• 12.UP Button:It is used to increase the value that is required to be adjusted.
• 13.DOWN Button:It is used to decrease the value that is required to be adjusted.
Communication of Remote Control Panel (RCP) is made possible by RS-485.
First Splash Screen:
I n f o r ma t i o n :
De v i c e d e f i n i t i o n
d o n e .
MO D B U S 1 6Vx 2 0 0 0A

2
• MODBUS is the name of loaded program, 16Vx2000A is the values of rated voltage and rated
current. If the program name, rated voltage and rated current is not available at the first start-up,
this means no communication and check the connection between device, remote control panel and
feeding voltage of device.
• if the communication is all right, MANUAL/SELECT Led or AUTO Led blinks. If the communication
is not available within 3 seconds, it gives No Communication warning and all leds except Power Led
turn off.
• If MANUAL/SELECT Led blinks, it means that you can check the rectifier on its own panel.
• If Auto Led blinks, it means that you can check the rectifier on this panel (via RS-485 or RS-232).
• On the screens except of Manuel Step and Pulse Base screens, aa/bb on the right top corner means
the location of ok (aa) and line number (bb).
• For example, 01/04 on the options screen, on the right top corner means the location of ok(01), and
line number(04) on the menu.
• On Manual Step and Pulse Base screens:aa:StepNo, bb:Step number.

3 Menu Tree
3.1 Main Menu Screen:
Ma i n Me n u 0 1 / 0 4
>P r o g r a m Ty p e
C o mm u n i . Ed i t
O p t i o n s
D e v i c e I n f o

3.2 Working Type Screen:


P r o g r am T y p e 0 1 / 0 4
>Ma n u a l P o t
Ma n u a l
Mu l t i S t e p
Pu l s e Ba s e

3.3 Communication Set Screen:


C o mm u . Ed i t 0 1 / 0 7
>A d d r e s s : 0 0 1
Ba u d Ra t e : 1 9 2 0 0
Qu e r yCo u n t : 0 0 4 9 0
Re p l yCo u n t : 0 0 4 8 6
Ad r F a i l C n t : 0 0 0 0 0
C r c F a i l C n t : 0 0 0 0 0
D i s c o n . C n t : 0 0 0 0 0

3.4 Options Screen:


Op t i o n s 0 1 / 0 5
>D o s i n g A h : 6 5 5 0 0
D o s i n g S e c : 0 1 0
A u t o S t a r t : Ac t i v e
E x t . S t a r t : Pu s h
I n c r eme n t : 0 0 0 1

3
3.5 Device Information Screen:
De v i c e I n f o 0 1 / 1 5
>R a t e d I : 0 2 0 0 0
Ra t e d V : 0 0 0 1 6
Re v Cu r r . : 0 0 0 0 0
Ac t u a l Ah : 0
To t a l Ah : 0
Do s i n g Ah : 0
P r o g . Name : MO D B U S
P r o g . Ve r : 1 . 0 0
RCP Ve r . : 1 . 2 8
RCP S e l c t : O t o - DC
Re l a y 1 : S t a t u s
Re l a y 2 : E r r , P r En d
Re l a y 3 : Do s i n g
E x i t No : 0 9
C omp . Da t e : 1 4 . 0 1 . 1 4

4 How to Make Adjustment?


For example, to adjust Dosage Ah which is among the options, press MANUAL/SELECT button while it
is on ok Dosage Ah and take it to the adjusted place where you want by pressing UP-DOWN BUTTONS
and ON/MODIFY buttons to save, OFF/MENU buttons to cansel or quit the settings.

• After pressing ON/MODIFY button, this information is given if required value is saved:

Ch a n g e s
s a v e d .

• After pressing ON/MODIFY button, this information is given if required value is not saved:

Ch a n g e s
c o u l d n o t b e s a v e d .

It asks whether the change will be saved or not if you press MANUAL Button:
Q u e s t i o n :
A r e Ch a n g e s b e
s a v e d ?
Y e s ( ON ) N o ( O F F )

Please press ON/MODIFY button to save, press OFF/MENU to cancel.

5 Operation Modes
There are 3 modes of operation on device. Manual Operation( Manual Pot, Manual ), Manual Stepped,
Pulse Base.
If you enter 000:00 to time part at Manual Pot, Manual or Manual Stepped and also to total time part
at Pulse Base, the device works indefinitely.
Waiting period and Ramp is in on the time.
ds:minute:second, sd:hour:minute.

4
5.1 Manual Operation, Manual Pot Operation
Operation on Manual Mode proceeds one step and there are Volt - Current - Ramp and Time parameters.
At Manuel Operation, Volt-Current set values are adjusted by buttons, but at Manuel Pot operation, it is
adjusted by Pots.
Display of This Operation:
Ma n u a l 0 1 / 0 6
>V o l t : +8 . 0 0
Cu r r e n t : +0 5 0 0
Wa i t T i me : 0 0 0 : 0 0
Ra mp : 0 0 0 : 0 0
T i me : 0 0 0 : 0 0
Po l a r i t y : +

On this screen, if you press ON/MODIFY button, the device begins to operate.
Waiting Period:When the device begins to operate, it does not work during the specified time. It continuous
to operate normally when this waiting period is up.

5.2 Manual Stepped Operation


Manuel Stepped operation includes 37 steps.Each step has Volt, Current, Waiting Period, Ramp, Time
parameters.
To continue in the Manual Stepped operation; Press OFF/MENU button 3 seconds long on Manual screen
,and come to the operation type screen.By pressing DOWN button, arrow comes to Manuel Stepped and
by MANUAL/SELECT button, Manuel Stepped operation type is chosen.

Ma n . P r o g r am
>S t e p s
F i r s t S t e p : 0 1
L a s t S t e p : 1 0
S t e p Ch a n g e : A u t o
S i n g l e S t e p : P a s s i v e

If you press ON/MODIFY button on this screen, device starts to work and it keeps operating from 37 no
step to 10 no step (incll) and the process finishes at the end of the expiry time of the last step.
If you press MANUAL/SELECT button while arrow is at the ’Steps’ line, you will see on the screen:

Mu l t i S t e p 0 1 / 3 7
>V o l t : +8 . 0 0
Cu r r e n t : +0 5 0 0
Wa i t T i me : 0 0 0 : 0 0
Ra mp : 0 0 0 : 0 0
T i me : 0 1 0 : 0 0
Po l a r i t y : +

Means of 01/37 is Step Number/Step Count.


If you press ON/MODIFY button on this screen, device begins to work and it keeps operating from 01 to
37 (including) and the process finishes at the end of the expiry time of the last step.
Main Menu ⇒ Options when External Start:Push, If device started by external command panel only
operates step 1 or step 2. On the control panel box if ’Stepped Pin’ connector is open circuit Step 1 will
be operated, if connector is short circuited Step 2 will be operated. When rectifier stopped, for 1 minute
’process end relay’ will stay closed. Relay releases with either rectifier start or pressing any button on
control panel.

5
6 Warning Messages
• If the states of warning are like ( Mains Fault, Over-Heat, Power Modules are Bad ), it gives this
warning:
Wa r n i n g :
De v i c e i s n o t
r e a d y t o s t a r t .

• If you start the device by exterior start, you press OFF/MENU button and get this warning:
Wa r n i n g :
De v i c e h a s s t a r t e d
b y e x t e r n a l u n i t .
Cmd . n o t a c c e p t e d !

• Before you press ON/MODIFY button on panel, be sure that AUTO Led is blinking.
Eğer If you press ON button while MANUAL/SELECT Led is blinking, this warning appears.
Wa r n i n g :
De v i c e i n ma n u a l mo d
P r e s s Au t o o n l o c a l
p a n e l .

7 Operating Position
The screen image of operating position of rectifier:
Ma n u a l
I : +2 0 0 0 S : 0 0 1 : 2 9 V
V : +1 0 . 8 8
Ru n n i n g

On this screen, to stop the device, press OFF/MENU button.


To make adjustment of voltage or current while operating, press MANUAL/SELECT button and make
such adjustments.
V letter appears when VOLT button is pressed, and A appears when AMPERE button is pressed.With
UP-DOWN BUTTONS it is Voltage when V letter appears and it is Current Set values when A letter
appears.

• On Manual, first line example:


Ma n u a l
• On Manual Stepped, first line example:
Mu l t i S t e p 0 1 / 3 7
Means of 01/37 is Step Number/Last Step.
• At the end of the operation ( when the time is up) P̈rocess Endäppears at the place of Öperating¨.

P r o c e s s En d ( x x )
The meaning of (xx) which is near the Process End: it informs from which way it has passed to
process end.
Numbers that are belong to process end passings:
• 01:It stopped as it came to the expiry time of last step of Manual Stepped.

6
• 02:The expiry time of single step on Manual Stepped.
• 03:It stopped as it reached to step end if the passing type is manual on Manual Stepped.
• 04:End of all steps on Manual Stepped.
• 05:It stopped as it got start while it is on UKP Automatic mode.
• 06:Exterior Start was stopped by pressing Push button.
• 07:Exterior Start was stopped by pressing Toggle button.
• 08:It was stopped as Off button was pressed from Panel.
• 09:It stopped as it was expiry time at Manual operation.
• 10:It stopped as Actuel Ampere timer reached to Ampere Timer Set value at Manual Operation.

7
Maintenance and Cleaning of the Rectifier
Actually, the device was designed needing as the least maintenance as possible.But it is necessary to
maintain and clean the device periodically just as every electrical appliance. Its cleaning is quite easy as
the exterior surface of device has oven-drying. So, it is enough to clean it with a piece of wet cloth. If
there is layer of oil on the surface, you can clean it with the help of liquid cleaner easily. Take care not
using hard cleaning materials. Never use supplies such as thinner, gasolin, solvent which may harm paint.
If there is a state of corrosion at connecting terminals, you can clean it with an emery. Protect your
device against dust, damp and other corrosive materials. Only the authorized personnels should carry out
maintanence of the device. Within that period, device cables should be controlled. If there is any one that
has bad isolation or has no more high-quality, they must be replaced with the original ones.If the device
is in an ambient that is prone to get dusty, then use compressed air to remove dust. Never clean inside of
device with a brush and so on. You may damage to highly delicate electronic parts without noticing. The
maintenance of the device must carried out by the technical service personnels at least once a year.
Technical Support
Please contact with our technical service in case of any device problem.Never respond to
the failure yourself.Otherwise, it may cause more damage.Here is our address and phone
number that enables you to contact with our technical service.

Organize Sanayi Bölgesi Tormak Sanayi Sitesi


P Blok 107.Sok No:32 İkitelli / İSTANBUL
Tel: 444 0 677
web: www.mrs.com.tr
e-mail: info@mrs.com.tr

C
CERTIFIED
MANUFACTURER
EC CONFORMITY DECLARATION
EC LOW VOLTAGE DIRECTIVE ACCORDING TO 73/23/EEC
EC CONFORMITY DECLARATION
CRS Endüstriyel Güç Sistemleri Ind. Trade Co. Ltd. declares that the devices which are
explained below, conform European Community basic health and safety regulations. This
declaration will lose validity in case of any change of the devices’ design or type.
Device Type and Class REMOTE CONTROL PANEL ( RCP )
Device Model PWM-Plus
AB Low Voltage Directive
(73/23/EEC)
Applicable EC Directives
89/336/EEC EC Electromagnetic Compatibility
(EMC) Directive (89/336/EEC)
EN 60335-2-29
Applicable Harmonize Standarts
ISO 9001:2000
Applicable National Technical Standarts
TS 60335-2-29
and Specifications
Publish Date
Authorized Person Kemal GENÇ
Title of Signatory General Manager
Authorized Signature