Sie sind auf Seite 1von 12

GE Healthcare

LOGIQ V2
Ultrasound System
LOGIQ V2 Ultrasound System Operating modes
• B-Mode
The LOGIQTM V2 is a compact designed ultrasound imaging system • Coded Phase Inversion Harmonic Imaging
designed for Abdominal, Obstetrical, Gynecological, Small Parts, • M-Mode
Vascular/Peripheral Vascular, Urological, Transcranial and Cardiac • Color M Mode
applications. • Color Flow Mode (CFM)
• Power Doppler Imaging (PDI)
General specifications • Directional PDI
• PW Doppler with High PRF
Dimensions and weight • Anatomical M-Mode (Option)
Height: 120mm • CW Doppler Mode (Option)
Length: 396mm
Width: 368mm
System standard features
Weight: 6kg with battery
AO (Automatic Optimization)
CrossXBeamTM
Electrical power
SRI-HD (High Definition Speckle Reduction Imaging)
Voltage: 100-240 VAC
B-Steer
Frequency: 50/60 Hz
Coded Phase Inversion Harmonic Imaging
Power consumption:
Virtual Convex
Maximum of 200 VA with peripherals Patient information Database
Image Archive on integrated HDD
Console design
Raw Data Analysis (TruScan)
1 inbuilt active probe ports
Real-time automatic Doppler calculations
2nd probe port with optional adapter
OB Calculations
Integrated HDD (120GB)
Fetal Trending
Integrated speakers
Multi-gestational Calculations
Hip Dysplasia Calculations
User interface Gynecological Calculations
Vascular Calculations
Operator keyboard Urological Calculations
Ergonomic full size keyboard Renal Calculations
8 TGC Slider segments (pods) Cardiac Calculations
Remote capability: InSite ExC
Monitor On-board reporting package
15” (381mm) high-resolution LCD (1024X768 pixels) MPEGVue
Brightness adjustment Network Storage

System overview System Options


Applications Auto-IMT
Abdomen CW Doppler
Obstetrics DICOM® 3.0 Connectivity
Gynecological Anatomical M-Mode (AMM)
Cardiac LOGIQ View
Vascular Easy 3D (Free Hand 3D)
Transcranial Scan Assistant
Musculoskeletal Scan Coach
Urological SonoBiometry
Small Parts
Pediatric & Neonatal

Scanning methods
Electronic Convex
Electronic Linear
Electronic Sector

Transducer types
Convex Array
Linear Array
Sector Phased Array
Peripheral Options Supported Display annotation
Digital UP-D25MD Color thermal printer Patient Name: First, Last (Max 28 characters displayed per each, Up
Digital UP-D897 BW thermal printer to 64 total characters per each)
Digital UP-D898MD BW thermal printer Patient ID (Max 54 characters)
HP office jet 100 Mobile Printer
HP office jet Pro 8100 Printer (supported) Other ID (Max 54 characters)
1-Pedal type footswitch ‘Whanam FSU-1000’ Age, Sex and Date of Birth
Footswitch MKF 2-MED USB GP26
Hospital Name (Max 23 characters displayed)
SanDisk USB Stick 4G
1TB mobile USB HDD Date format: 3 Types selectable
DVD RW Kit, LITEON eUAU108 • MM/DD/YY
Wireless USB adapter • DD/MM/YY
• YY/MM/DD
Display modes
Live and Stored Display Format: full size and Split screen – both with Time format: 2 types selectable
thumbnails for still and Cine • 24 hours
Review Image Format: 4x4 and “thumbnails” for still and Cine • 12 hours
Simultaneous Capability
Gestational Age from
• B/PW
• LMP • GA
• B/CFM or PDI
• EDD • BBT
• B/M
• B/CrossXBeam Displayed Acoustic Output
• B + CFM/M • TIS: Thermal Index Soft Tissue
• Real Time Triplex Mode (B + CFM or PDI/PW or CW) • TIC: Thermal Index Cranial (Bone)
• Dual B (B/B) • TIB: Thermal Index Bone
• MI: Mechanical Index
Selectable alternating Modes % of Maximum Power output
• B/M
Probe Name
• B/PW
Map Names
• B + CFM/M
Probe Orientation
• B + CFM (PDI)/PW (CW)
Depth Scale Marker
• 3D-Mode
Lateral Scale Marker
• 3D-Mode Color
Focal Zone Markers
• B/CW (Option)
Image Depth
• B + CFM (PDI)/CW
Zoom Depth
• Multi-image split screen (quad screen)
• Live and/or frozen B-Mode
• B + B/CFM or PDI • Gain
• PW/M • Dynamic Range
• Independent CINE playback • Imaging Frequency
• Zoom: Write/Read/Pan • Edge Enhance
• Frame Average
Colorized Image • Frame Rate
• Colorized B • Gray Map
• Colorized M • ATO On/Off
• Colorized PW • SRI-HD
• Colorized CW • CrossXBeam

Time line display M-Mode


• Independent Dual B/PW or CW Display
• Gain
• Display Formats
• Time Scale
-- Top/Bottom selectable format (Size: 1/2:1/2; 1/3:2/3; 2/3:1/3)
-- Side/Side selectable format (Size: 1/2:1/2; 1/4:3/4; TL only)

Switchable after Freeze


• Timeline only
• Virtual Convex
• CrossXBeam
Doppler Mode CINE Memory/Image Memory
• Gain System RAM: 2GB
• Angle Processor: Intel Celeron 1047 (1.4G x2 core)
• Sample Volume Depth and Width 128 MB of Cine Memory
• Wall Filter Max number of Cine loops: 2269 frames
• Velocity and/or Frequency Scale Selectable Cine Sequence for Cine Review
• Spectrum Inversion Prospective Cine Mark
• Time Scale Measurements/Calculations and Annotations on Cine Playback
• PRF Scrolling timeline memory
• Doppler Frequency Dual Image Cine Display
Quad Image Cine Display
Color Flow Mode Cine Gauge and Cine Image Number Display
• Line Density Cine Review Loop
• Frame Average Cine Review Speed: 11 steps (11, 13, 14, 17, 22, 25, 31, 48, 100,
• Packet Size 200, 400%)
• Color Scale: 2 types
-- Power Image Storage
-- Directional PDI On-board database of patient information
• Color Velocity Range and Baseline Storage Formats:
• Color Threshold Marker • DICOM – compressed/uncompressed, single/multi-frame, with/
• Color Gain without Raw Data
• PDI • Display Format: Full Size, 4x4 and “thumbnails”
• Inversion • Storage Devices:
• Doppler Frequency • Internal Hard Drive Partition of 55 GB for Image Storage. At 22KB/
image, it can store 2,621,440 still images.
TGC Curve • External SD card, USB HDD and USB Memory Stick Support for
Cine Gage, Image Number/Frame Number Import, Export, DICOM Read, SaveAs, and MPEGVue
Body Pattern: Multiple human • CD-RW storage: 700 MB
Application Name • DVD storage: -R (4.7 GB)
Measurement Results Conversion to Formats: JPEG, AVI, WMV
Operator Message Live Image and stored image side-by-side Display
Biopsy Guide Line and Zone Compare stored images with current exam
Heart Rate Storematrix: 800 x 600 x 24 Bit (Image Only)
1024 x 768 x2 4 Bit (Normal Display)
General System Parameters Reload of archived data sets
Network Storage support for Import, Export, DICOM Read,
System Setup SaveAs, MPEGVue
• 8 Pre-programmable Categories
• User Programmable Preset Capability Connectivity & DICOM
• 248 presets (8 (application groups) x 4 (user defined) +
30(applications) ) x 4 (probes) Ethernet network connection
• Factory Default Preset Data • DICOM 3.0 (Optional)
• 120 presets (30(applications) x 4 (probes)) • Verify
• Languages: English, Latin American Spanish, French, German, • Print
Italian, Brazilian Portuguese, Chinese (Simplified), Swedish, Russian, • Store
Norwegian, Danish, Dutch, Finnish, Japanese • Modality Worklist
• OB Report Formats including Tokyo Univ., Osaka Univ., USA, Europe, • Storage Commitment
and ASUM • Modality Performed Procedure Step (MPPS)
• User Defined Annotations • Query/Retrieve
• Body Patterns • Structured Reporting Template – which can be compared to
• Customized Comment Home Position vascular and OB standard
• System Boot-up Time: 120 seconds • Remote capability InSite ExC
• System Shut-down Time: 40 seconds
• BTU (Heat dissipation): Typical Input power during scanning with
full configuration: 511 BTU (th) / hr. (1BTU=0.293071W)
Scanning Parameters Pulse Wave Doppler Mode
Digital Agile Beamformer Architecture • Acoustic Power: 0 – 100%, 2, 5, and 10 steps
193,536 System Processing Channels • Gain: 0 -85 dB, 1 dB step
Max. Frame Rate: 1100 F/s • Gray Scale Map: Up to 8 types
Displayed Imaging Depth: 0 – 33 cm • PRF: 0.3 – 27.9 KHz
Minimum Depth of Field: 0 – 2 cm (Zoom) (probe dependent) • Transmit Frequency: 1.7~6.3MHz,probe depend
Maximum Depth of Field: 0 – 33 cm (probe dependent) • Wall Filter: 5.5 – 5000Hz, 27 steps, dependent on probe
Transmission Focus: 1 – 8 Focal Points selectable (probe and • PW Colorization: Up to 6 types
application dependent) • Velocity Scale Range: 0.4 ~ 4084 cm/s
Quad Beamforming • Sweep Speed: 0~7, 8 steps
Continuous Dynamic Receive Focus/Aperture • Sample Volume Depth: 0.2~30 cm, probe depend
Multi-Frequency/Wideband Technology • SV Gate: 1, 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16 mm
Frequency Range: 1.7 to 13 MHz • Angle Correction: -90 to +90degree, 1 degree steps
Max Frequency Bandwidth: 13MHz • M/PW Display Format: V-1/3B, V-1/2B, V-2/3B, H-1/2B, H-1/4B,
256 Shades of Gray Timeline only
224dB Composite Dynamic Range • Spectrum Inversion
Adjustable Dynamic Range (36 - 96dB) • Duplex: Simultaneous: On/Off (PW only)
Adjustable Field of View (FOV): up to 128 degree • PW Angle Steer: 0, ±10, 15, 20˚
(depending on probe) • Sample Volume Depth: 75 steps default pre-settable, probe
Image Reverse: Right/Left dependent
Image Rotation of 0,° 180° • Trace Method: Off, Max, Mean
• Baseline Shift: 11 steps
B-Mode • Doppler Auto Trace
Acoustic Power Output: 0 – 100%, 2, 5, and 10 steps • Compression: 0.5~2.4 9steps (0.5,0.7,0.9,1,1.1,1.4,1.6,2,2.4)
Gain: from 0 – 90 dB, 1 dB steps • Trace Direction: Above, Below, Both
Adjustable Dynamic Range: 36 – 96 dB, 3 or 6 dB steps • Trace Sensitivity: 0~40, 2 steps
Frame Average: 8 steps, probe depend
Gray Scale Map: 7 types, probe depend Color Flow Mode
Colorize Map / Tint Map: 9 types Baseline Shift: 0-100%/11 steps
Frequency: Up to 11 selectable (depending on probe) Invert: On/Off
Line Density: 5 steps CF/PDI Focus Depth: default pre-settable for 10 – 100% of ROI in
Line Density Zoom: 5 steps depth, 10% or 16% step
Thermal Index: TIC, TIS, TIB CF/PDI Flash Suppression: 5 steps
Image Reverse: On/Off CF/PDI Angle Steer: 0, ±10˚, ±15˚, ±20˚
Maximum Focus Number: 8 steps on any probe/application Packet Size: 8 – 24, dependent on probe and Application
Focus Width: 3 types Line Density: 5 steps
Suppression: 6 steps Line Density Zoom: 5 steps
Edge Enhance: 7 steps Frame Average: 7 steps
Rejection: 6 steps PRF: 0.1 – 18.5 KHz/19 steps
Steered Linear: ±15˚ Min PRF: 0.1 KHz; Max PRF: 18.5KHz
Scanning Size (FOV or Angle – depending on the probe) Velocity Range: 2 - 300 cm/s
SRI-HD: Up to 6 Levels selectable Spatial Filter: 6 steps
CrossXBeam: Up to 7 Angles selectable Gain: 0 – 40 dB, 0.5 dB per step (totally 81 steps)
Depth: 2 – 33 cm, 0.5 or 1 cm step, Probe dependent Wall Filter: 0-3 / 4 steps, dependent on probe and Application
Scanning Size (FOV or Angle): Probe dependent
M-Mode CF/PDI Vertical Size (mm) of ROI: default pre-settable
Gain: –20 -20 dB, 1 dB step CF/PDI Center Depth (mm) of ROI: default pre-settable
Gray Scale Map: 7 types CF/PDI Frequency: Up to 4, depending on probe
B Colorization: 9 types Color Maps, including velocity-variance maps: 14 types depending
Scanning Size (FOV or Angle – depending on probe, see probe on Application
specifications) Transparent: 5 steps
Rejection: 6 steps Echo/Color Priority: 0 - 100%/11 steps (Color Threshold)
M/PW Display Format: V-1/3B, V-1/2B, V-2/3B, H-1/2B, Accumulation: 8 steps
H-1/4B,Timeline only Max. Frame Rate: 324 fps (3Sc probe)
Max FR in Triplex: 307 fps
Anatomical M-Mode (Option)
M-Mode cursor adjustable at any plane
Can be activated from a Cine loop from a live or stored image
M and A capability
Available with Color Flow Mode
Power Doppler Imaging Coded Harmonic Imaging
PDI Map: 14 types Coded Phase Inversion Harmonic Imaging
CF/PDI Focus Depth: default pre-settable for 10 – 100% of ROI in Available on all Probes
Depth, 10% or 15% step Line Density: 5 steps
CF/PDI Acoustic Output: 0 – 100%, 2%, 5% or 10% step Line Density Zoom: 5 steps
CF/PDI Angle Steer: 0, ±10˚, ±15˚, ±20˚ Suppression: 6 steps
Packet Size: 8 – 24, dependent on probe and application Edge Enhance: 7 steps
Spatial Filter: 6 steps Gray Scale Map: 7 types
Frame Average: 7 steps Tint Map: 9 types
PRF: 0.1 – 18.5 KHz/19 steps Gain: 0 – 90 dB, 1 dB step
Power Threshold: 0 – 100%, 10% steps Dynamic Range: 36 to 96dB, 36~48/78~96 6dB step;
Gain: 0 – 40 dB, 0.5 dB steps Rejection: 6 step
Wall Filter: 4 steps depending on probe and application Frequency: Up to 4 steps, probe depended
CF/PDI Frequency: Up to 4 steps, depending on probe
Transparent: 5 steps LOGIQView (Option)
Invert: On/Off Extended Field of View Imaging
Accumulation: 8 steps For use in B-Mode
Flash Suppression CrossXBeam is available on linear probes
Auto detection of scan direction
Continuous Wave Doppler (Option) Post-process zoom
Gray Scale Map: 8 types Rotation
Baseline: 11 steps Auto fit on monitor
Angle Correct: ±90˚, 1˚ step Measurements in B-Mode
Spectral Color: 6 types Up to 60cm scan length
Invert: On/Off
Gain: 0 – 85 dB, 1 dB steps Easy 3D (Option)
Wall Filter: 5.5 – 5000Hz, 27 steps, dependent on probe Allows unlimited rotation and planar translations
and application 3D reconstruction from Cine sweep
CW-Mode includes:
• Transmit Frequency Scan Assistant (Option)
• CW Colorization Factory Programs
• Velocity Scale Range: 6 ~ 6004cm/s User defined programs
• Spectrum Inversion Steps include image annotations, mode transitions, basic imaging
• Trace Method controls and measurement initiation
• Doppler Auto Trace
• Trace Direction Scan Coach (Option)
• Trace Sensitivity Modules showing basic scanning techniques with graphic of beam
formation, indicative probe position, schematic of anatomy and
Spectral Doppler Mode example clinical reference image. Covers Obstetrics, Gynecology &
PRFs: 0.3 – 27.9 KHz Abdomen applications.

Velocity Range (PW) : Min: 1 cm/s SonoBiometry (Option)


Max: 4711 cm/s with 80 Angle Correction SonoBiometry is a workflow tool available on the LOGIQ Vision series
Max: 1636 cm/s with 60 Angle Correction that automatically places calipers for fetal biometry measurements,
Max: 818 cm/s with 0 Angle Correction thus helping the user to perform these fetal measurements quickly.
This tool can help enhance clinical workflow by reducing keystrokes
Velocity Range (CW): Min: 6cm/s to perform biometry measurements. Additionally, the user has the
Max: 6004cm/s with 80 Angle Correction option to either accept or edit the measurement suggested by
Max: 2120cm/s with 60 Angle Correction this tool.
Max: 1060cm/s with 0 Angle Correction
Algorithms: Auto measurement of Bi-Parietal Diameter, Head
Circumference, Abdominal Circumference & Femur Length
Auto Optimization
Optimize B-Mode image to improve contrast resolution
Selectable amount of contrast resolution improvement
(low, medium, high)
Auto-Spectral Optimize adjusts
• Baseline
• Invert
• PRF (on live image)
• Angle correction
Virtual Convex Controls Available on “Freeze” or Recall
Provides a convex field of view Automatic Optimization
Compatible with CrossXBeam SRI-HD
Available on linear and Sector transducers CrossXBeam – Display non-compounded and compounded
image simultaneously in split screen
SRI-HD 3D reconstruction from a stored Cine loop
High Definition Speckle Reduction Imaging Provides multiple levels of B/M/CrossXBeam Mode
speckle reduction Gray Map Optimization
Compatible with Side by Side DualView Display TGC
Compatible with all linear, convex and sector transducers Colorized B and M
Compatible with B-Mode, 3D/4D imaging Frame Average (loops only)
Dynamic Range: Anatomical M-Mode
CrossXBeam Sweep Speed
Provides 3, 5, 7 of spatial compounding Gray Map
Live Side by Side DualView Display Compatible with: Post Gain
• Color Mode Baseline shift
• PW Sweep Speed
• SRI-HD Invert Spectral wave form
• Coded Harmonic Imaging Compression
• Virtual Convex Rejection
Available on 4C-RS, L6-12-RS, E8C-RS 12L-RS, 8C-RS and LK760-RS. Colorized Spectrum
Display Format
Controls Available While “Live” Doppler Audio
Write Zoom Angle Correct
B/M/CrossXBeam-Mode Quick Angle Correct
Gain Auto Angle Correct
TGC Overall Gain (loops and stills)
Dynamic Range Color Map
Acoustic Output Transparency Map
Transmission Focus Position Frame Average (loops only)
Transmission Focus Number Flash Suppression
Line Density Control CFM Display Threshold
Sweep Speed for M-Mode Spectral Invert for Color/Doppler
Number of Angles for CrossXBeam Anatomical M-Mode on Cine loop
PW-Mode
Gain
Dynamic Range
Measurements/Calculations
Acoustic Output General B-Mode
Transmission Frequency Depth and Distance
PRF Circumference (Ellipse/Trace)
Wall Filter Area (Ellipse/Trace)
Spectral Averaging Volume (Ellipsoid)
Sample Volume Gate % Stenosis (Area or Diameter)
• Length Angle between two lines
• Depth
Velocity Scale General M-Mode
Color Flow Mode M-Depth
CFM Gain Distance
CFM Velocity Range Time
Acoustic Output Slope
Wall Echo Filter Heart Rate
Packet Size
Frame Rate Control
CFM Spatial Filter
CFM Frame Average
Frequency/Velocity Base Line Shift
General Doppler Measurements/Calculations Calculations and Ratios
Velocity • FL/BPD
Time • FL/HC
A/B Ratio (Velocities/Frequency Ratio) • CI (Cephalic Index)
PS (Peak Systole) • CTAR(Cardio-Thoracic Area Ratio)
ED (End Diastole) Measurements/Calculations by: ASUM, ASUM 2001, Berkowitz,
PS/ED (PS/ED Ratio) Bertagnoli, Brenner, Campbell, CFEF, Chitty, Eik-Nes, Ericksen,
ED/PS (ED/PS Ratio) Goldstein, Hadlock, Hansmann, Hellman, Hill, Hohler, Jeanty,
AT (Acceleration Time) JSUM, Kurtz, Mayden, Mercer, Merz, Moore, Nelson, Osaka
ACCEL (Acceleration) University, Paris, Rempen, Robinson, Shepard, Shepard/Warsoff,
TAMAX (Time Averaged Maximum Velocity) Tokyo University, Tokyo/Shinozuka, Yarkoni
Volume Flow (TAMEAN and Vessel Area) Fetal Graphical Trending
Heart Rate Growth Percentiles
PI (Pulsatility Index) Multi-Gestational Calculations (4)
RI (Resistivity Index) Fetal Qualitative Description (Anatomical survey)
Fetal Environmental Description (Biophysical profile)
Real-time Doppler Auto Measurements/Calculations Programmable OB Tables
PS (Peak Systole) Over 20 selectable OB Calculations
ED (End Diastole) Expanded Worksheets
MD (Minimum Diastole)
PI (Pulsatility Index) GYN Measurements/Calculations
RI (Resistivity Index) Right Ovary Length, Width, Height
AT (Acceleration Time) Left Ovary Length, Width, Height
ACC (Acceleration) Uterus Length, Width, Height
PS/ED (PS/ED Ratio) Cervix Length, Trace
ED/PS (ED/PS Ratio) Ovarian Volume
HR (Heart Rate) ENDO (Endometrial thickness)
TAMAX (Time Averaged Maximum Velocity) Ovarian RI
PVAL (Peak Velocity Value) Uterine RI
Volume Flow (TAMEAN and Vessel Area) Follicular measurements
Summary Reports
OB Measurements/Calculations
Vascular Measurements/Calculations
Gestational Age by: SYS DCCA (Systolic Distal Common Carotid Artery)
• GS (Gestational Sac) DIAS DCCA (Diastolic Distal Common Carotid Artery)
• CRL (Crown Rump Length) SYS MCCA (Systolic Mid Common Carotid Artery)
• FL (Femur Length) DIAS MCCA (Diastolic Mid Common Carotid Artery)
• BPD (Biparietal Diameter) SYS PCCA (Systolic Proximal Common Carotid Artery)
• AC (Abdominal Circumference) DIAS PCCA (Diastolic Proximal Common Carotid Artery)
• HC (Head Circumference) SYS DICA (Systolic Distal Internal Carotid Artery)
• APTD x TTD (Anterior/Posterior Trunk Diameter by Transverse DIAS DICA (Systolic Distal Internal Carotid Artery)
Trunk Diameter) SYS MICA (Systolic Mid Internal Carotid Artery)
• FTA (Fetal Trunk Cross-sectional Area) DIAS MICA (Diastolic Mid Internal Carotid Artery)
• HL (Humerus Length) SYS PICA (Systolic Proximal Internal Carotid Artery)
• BD (Binocular Distance) DIAS PICA (Diastolic Proximal Internal Carotid Artery)
• FT (Foot Length) SYS DECA (Systolic Distal External Carotid Artery)
• OFD (Occipital Frontal Diameter) DIAS DECA (Diastolic Distal External Carotid Artery)
• TAD (Transverse Abdominal Diameter) SYS PECA (Systolic Proximal External Carotid Artery)
• TCD (Transverse Cerebellum Diameter) DIAS PECA (Diastolic Proximal External Carotid Artery)
• THD (Thorax Transverse Diameter) VERT (Systolic Vertebral Velocity)
• TIB (Tibia Length) SUBCLAV (Systolic Subclavian Velocity)
• ULNA (Ulna Length) Automatic IMT
• Estimated Fetal Weight (EFW) by: Summary Reports
• AC, BPD
• AC, BPD, FL, HC Urological Calculations
• AC, FL, HC Bladder Volume
• BPD, APTD, TTD, FL Prostate Volume
Lt/Rt Renal Volume
Generic Volume
Post-Void Bladder Volume
Cardiac Measurements/Calculations 3Sc-RS
Cardiac calculation package including extensive Phased Array Sector Probe
measurements and display of multiple repeated • Frequency Range: 1.7 – 4.0 MHz
measurements Parameter annotation follow • Applications: Cardiac, Transcranial
ASE standard • Number of Element: 64
• FOV: 120°
Probes • Footprint: 27.6 x 19.3 mm
• B-Mode Imaging Frequency: 2.0, 3.0, 4.0 MHz
4C-RS • Harmonic Imaging Frequency:
Convex Probe 3.0, 3.2, 3.5, 4.0 MHz
• Frequency Range: 2.0-5.0MHz • CFM/PDI/PWD Frequency: 1.7, 2.0, 2.5, 3.3 MHz
• Applications: Abdomen, OB/Gyn, Vascular, Urology • CWD Frequency: 1.9 MHz
• Number of Element: 128 • Biopsy Guide: Multi Angle, Reusable Bracket
• Convex Radius: 60 mmR
• FOV: 55° 8C-RS
• Footprint: 18.3 x 66.2 mm Convex Probe
• B-Mode Imaging Frequency • Frequency Range: 4.2 – 10.0 MHz
2.0, 3.0, 4.0, 5.0 MHz • Applications: Pediatric ,cardiac, Small Parts
• Harmonic Imaging Frequency: • Number of Element: 128
3.0, 4.0, 5.0 MHz • Convex Radius: 10.73 mmR
• CFM/PDI/PWD Frequency: 2.0, 2.8, 3.6 MHz • FOV: 128°
• Biopsy Guide: Multi Angle, Reusable Bracket • Footprint: 12.0 x 22.0 mm
• B-Mode Imaging Frequency
L6-12-RS 6.0 8.0 10.0 MHz
Linear Probe • Harmonic Imaging Frequency:
• Frequency Range: 4.0 – 13.0 MHz 7.0 8.0 10.0 MHz
• Applications Vascular, Small Parts, Pediatrics • CFM/PDI/PWD Frequency: 4.2 5.0 6.3 MHz
• Number of Element: 128
• Footprint: 38.4 x 6.0 mm 12L-RS
• B-Mode Imaging Frequency: Linear Probe
6.0, 8.0, 10.0, 11.0 MHz • Frequency Range:4.2– 13.0 MHz
• Harmonic Imaging Frequency: • Applications: Vascular, Small Parts, Pediatrics
8.0, 10.0, 12.0, 13.0 MHz • Number of Element: 192
• Highest Linear Harmonics: 13MHz • Footprint: 12.7 x 47.1mm
• CFM/PDI/PWD Frequency: 4.0, 5.0, 6.0 MHz • B-Mode Imaging Frequency:
• Steered Angle : +/-20°° 6.0, 8.0, 10.0, 12.0 MHz
• Steering steps: 23 steps, in Fine Angle Steer (from -20 to +20, 1 or 2 • Harmonic Imaging Frequency:
degree steps) 8.0, 10.0, 12.0, 13.0 MHz
• Max Steering Angle: +- 20 degrees in Fine Angle Steer • Highest Linear Harmonics: 13MHz
• Biopsy Guide: Multi Angle, Reusable Bracket • CFM/PDI/PWD Frequency:4.2 6.3 7.7 MHz
• Steered Angle : +/-20°°
E8C-RS • Steering steps: 23 steps, in Fine Angle Steer (from -20 to +20, 1 or 2
Endo Micro Convex Probe degree steps)
• Frequency Range: 4.2 – 10.0MHz • Max Steering Angle: +- 20 degrees in Fine Angle Steer
• Applications: OB/Gyn, Urology, Transvaginal, • Biopsy Guide: Multi Angle, Reusable Bracket
• Transrectal
• Number of Element: 128 LK760-RS
• Convex Radius: 10.73 mmR Linear Probe
• FOV: 128° • Frequency Range: 5.0-10.0 MHz
• Footprint: 16.9 x 21.2 mm • Applications:Small Parts
• B-Mode Imaging Frequency: 6.0, 8.0, 10.0 MHz • Number of Element: 128
• Harmonic Imaging Frequency: • Footprint: 38.4 x 6.0 mm
7.0, 8.0, 10.0 MHz • B-Mode Imaging Frequency:
• CFM/PDI/PWD Frequency: 4.2, 5.0, 6.3 MHz 5.0 7.0 9.0 MHz
• Biopsy Guide: Fixed Angle, • Harmonic Imaging Frequency:
• Disposable, or Reusable Bracket 6.0 8.0 10.0 MHz
• Highest Linear Harmonics: 10.0 MHz
Inputs and Outputs
HDMI output
VGA output with optional adapter
TV output (S-video and composite video)
100BASE-TX Ethernet (RJ45)
2 USB ports

Safety Conformance
The LOGIQ V2 is:
CE Marked to Council Directive 93/42/EEC on Medical Devices
Conforms to the following standards for safety:
• IEC 60601-1 Medical electrical equipment—Part 1: General
• requirements for safety
• IEC 60601-1-2 Medial electrical equipment—Part 1-2 General
requirements for safety—Collateral Standard: Electromagnetic
compatibility—requirements and tests EMC Emissions Grp-1
• Class A device requirements as per CISPR 11
• IEC 60601-2-37 Medical electrical equipment—Part 2-37: Particular
requirements for the safety of ultrasonic medical diagnostic and
monitoring equipment
• ISO 10993-1 Biological evaluation of medical devices—Part 1
Evaluation and testing
• EN 62366 Medical devices —Application of usability engineering to
medical devices
About GE Healthcare
GE Healthcare provides transformational medical technologies and
services to meet the demand for increased access, enhanced quality
and more affordable healthcare around the world. GE (NYSE: GE)
works on things that matter - great people and technologies taking
on tough challenges. From medical imaging, software & IT, patient
monitoring and diagnostics to drug discovery, biopharmaceutical
manufacturing technologies and performance improvement
solutions, GE Healthcare helps medical professionals deliver great
healthcare to their patients.

GE Healthcare GE Healthcare GmbH


Pollards Wood, Nightingales Ln Beethovenstr. 239
Chalfont St Giles 42655 Solingen, Germany
Buckinghamshire HP8 4SP T +49 212-28 02-0
United Kingdom F +49 212-28 02-28
Phone:+44 1494 544000

www.gehealthcare.com

Imagination at work

Data subject to change


© 2015 General Electric Company. July 2015/DOC1730282
GE, the GE Monogram, imagination at work and LOGIQ are trademarks of
General Electric Company.
Trademark of General Electric Company.
DICOM is the registered trademark of the National Electrical Manufacturers Association
for its standard publications relating to digital communications of medical information.
GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, a General Electric
Company, doing business as GE Healthcare.

Reproduction in any form is forbidden without prior written permission from GE. Nothing
in this material should be used to diagnose or treat any disease or condition. Readers
must consult a healthcare professional.