Sie sind auf Seite 1von 8

Release Notes for Altium Designer Version 16.

1
Modified by Maksim Feshchanka on 2-May-2016

Version 16.1.7
Build: 188 Date: 2 May 2016

Vault Component Template, specified in the Folder properties, is no longer erased


11325
after new revision of the template is created.

Document parameters are now support in the BOM template, when the source
3387
document is an ActiveBOM.

Placed schematic component parameter settings are now preserved when the Vault
9818
component is updated to the latest revision.

Update to latest version does not cause solution ranks reset for the component in
9819
ActiveBOM.

10295 All Suppliers now connect correctly when there is a proxy server in use.

Multi-line text string properties are now correctly retained when a footprint is
11359
released to the Vault.

Even though component release failed, under certain conditions the CmpLib would
11556 close. This no longer occurs, the CmpLib now remains open until all components
have been successfully released.

Vault Explorer - Fixed floating bug with model preview download when using https
11685
connection.

Fixed bug in Vault Explorer, which limited a maximum of 100 templates being
11849
displayed in the properties dialog.

11135 Connection to the Private License Server is now being restored automatically.
Altium Designer would occasionally generate an assertion failure during PCB import
7317
using the Mentor Expedition Importer, this no longer occurs.

ODB++ viewers can return a "No token" failure if the PCB component has an empty
8922
name field, this situation is now detected and resolved during ODB++ generation.

A footprint comparison performed through an OutJob now correctly detects hole size
9423
differences.

Fixed an issue where alternative parts were missing in the Pick & Place file in a
9603 multichannel design. This fix requires that the Variant Management dialog be opened
and closed, to re-validate the variant data. (BC:5791)

Single Pin Nets report now correctly generates a report for the entire project, rather
6343
than the current sheet. Note that this report detects named single pin nets.

If a dimension is in a union with a component, the dimension now retains its


8917
association with that component when the component is moved.

8918 Arc radius inside of the differential pair is now changed as expected during dragging.

8921 Show Pad Numbers option in the Printout Properties dialog now functions correctly.

Resolved an issue when in mirrored Design View copper was displayed in draft mode
8926
and no holes were visible.

The tracks and arcs in a hatched polygon are no longer checked against the routing
8927
width design rule.

Fixed a regression issue where the generated PDF was doubled in size compared to
8928
earlier versions of Altium Designer.

Improved PADS import for components with multiple footprints of the same part
8930
type.

8932 Resolved an issue where designators were hidden after importing an Orcad .max file.

8935 Resolved an issue where there was a delay when moving an Embedded Board Array.
Resolved an issue where DXF export of the drill drawing layer would use circles
8939
instead of the specified drill symbols.

Resolved an issue where the Gerber Output would include a zero value D Code for
8940 certain values of a round pad with the Paste Mask Expansion equal to minus one half
of the pad size.

Design View are now correctly displayed if placed on a mechanical layer, and that
8946
layer has the Linked to Sheet option enabled.

Right-clicking over overlapping PCB polygons, with the Display popup selection
8947
dialog option enabled, now behaves correctly.

Components which have pads outside the workspace limits no longer cause the
8949
software to hang, displaying "Analyzing Nets".

8951 The Edit xSignal Class dialog now supports resizing. (BC:5368)

The Hyperlynx Exporter no longer gives an exception when the design includes a
8955
polygon with a large number of vertices.

8957 Gerber Batch import now works correctly.

Entering the string ".comment" into the Comment field of a PCB component no
8958
longer causes an exception.

Length tuning accordion objects can now be selected using the Find Similar Objects
8960
dialog.

The Radial Diameter Symbol now exports correctly during PDF Output, when the
8961
Stroke font option is used.

Placing a via during interactive routing, in Any Angle mode, with an SMD To Corner
8962
rule defined, no longer results in invalid behavior.

Single layer pads on a mechanical layer, with a hole size greater than zero, are no
9086
longer included in drill outputs.
PCAD PCBLib Exporter is now included in the software, as it was before version
9195
15.0.

The PCB editor String dialog now uses Enter to accept and close the dialog, instead
9263
of entering a new line in the string. Use Shift+Enter to add a new line to the string.

When importing an OrCAD library the component Comment field is now handled
9278
correctly.

Footprint assignment and rotation is now correctly managed during PADS PCB
9601
import.

The "Forgotten Password" option on the Altium Designer License Management page
9778
now works correctly.

The OrCAD translator could fail on designs with certain bus configurations, this has
9892
been resolved.

Certain schematic designs would result in empty printouts for some sheets, this has
9930
been resolved.

Importing a large Allegro design could result in an "Out of memory" error, this has
9951
been resolved.

Importing a large CADSTAR design could result in an import error, this has been
10009
resolved.

An issue where the Eagle importer would sometimes assign items to the wrong
10373
Altium Designer layer, has been resolved.

10480 SCH List panel now includes the Text String object type in the Display objects filter.

The duplication of the S shortcut in the schematic editor Design menu has been
10508
resolved.

10535 The Import Wizard now supports resizing.


The incorrect use of a colon character in a project name is now detected and
10560
prevented.

Unconnected/Floating Net labels within a schematic Blanket are now detected and
10803
reported correctly.

The detection of directives placed on a blanket has been improved, to ensure they
10831 associate to the correct blanket. Blankets should be separated at least by the blanket
line width to ensure correct directive association.

10837 Dashed lines now copy/paste correctly to other Windows applications.

An issue where updating a schematic component from a library would result in the
10857
location of parameters being incorrectly changed, has been resolved.

"Preserve parameter visibility" setting is now used during update from library to
10858
control Comment parameter visibility.

NC Drill Fabrication output now produces correct Drill Layer field values in
9706
the .LDP file.

8936 Fixed issue with circular board shape modification after design reopen.

9259 Improved behavior when editing a long string in the PCB String properties dialog.

Added a check to STEP export to test for board availability in the design view,
10506
needed to resolve an export exception in a specific board.

An issue where polygons on an embedded array could be omitted during Gerber


11459
generation when the embedded array is within a polygon cutout, has been resolved.

Export of Gerber data now produces the correct apertures for stroking arc shapes
8943
(round apertures instead of oblong).

Mounting-hole are not being moved to another place after ODB++ generation (for the
8945
design containing footprints with empty name).
An inverted multi-line string on the overlay no longer produces violations to itself
9328
when performing a batch DRC via an outjob.

Removed the irrelevant hint about zero Slot Length for SMD pads in the Pad
9414
properties dialog, during switching of units.

Resolved an issue where the wrong template via would be placed during routing,
9437 occurred when there are two applicable rules, each targeting a different layer-pair,
one constrained by Min/Max Preferred, the other constrained by Template preferred.

Resolved an issue where a negative Mask expansion on a rectangular pad gave a zero
9469
sized opening, resulting in a zero sized Gerber aperture.

Fixed an issue in which Drill Drawing symbols were not visible inside of the Design
9535
View during output generation. (BC:5122)

Vias from old designs with defined attribute IsTearDrop are no longer removed
9537
during track modification.

Resolved an issue where a split line could move when the board shape was edited in
9538
Board Planning Mode.

The Via Shielding Tool now omits vias that violate clearance to solid copper regions
9546
and fills.

After adding shielding vias to PCB design, exception violation condition on File
9547
Open has been corrected.

Resolved an exception that could occur when output generation was launched, for a
9567
project where the referenced PCB file had been removed.

Gerber X2 fabrication output was slightly modified to comply with Gerber X2 Rev
9650
2015.10.

9725 Improved the handling of track width assignment during AutoCAD import.

Units are no longer appended while typing a value into the Pin/Pkg Length field in
9973
the Schematic Pin Properties dialog, they are now added when the dialog is closed.
Default settings are now applied correctly during footprint placement from a Library
10309
(already worked correctly during ECO-type placement).

Fixed Gerber generation of Solder and Paste masks for Mirrored Embedded Board
10323
Arrays. (BC:2850)

10355 Restored ability to print html reports using context menu.

Improved visual representations for non-selected Board Arrays and Design View
10358
objects.

An option has been added to automatically re-link any components that are currently
10417
un-linked during the Update PCB process.

Drill Tables with explicitly defined drill pairs are now being exported only to the
10479
Gerber layer dedicated to that pair.

Resolved an issue where a rectangular pad hole was exported as a square, during
10622
STEP generation.

PCB Rules And Violations panel is no longer shown automatically, after DRC
11195
completion.

Resolved an issue where the 3D model selection option changed from STEP model to
11358
extruded 3D Body, after model file replacement. (BC:6310)

Resolved an issue where an Assembly Drawing would incorrectly display the not-
11360
fitted symbol when the Mirror option was used in a printout. (BC:6424)

Resolved an issue where the Details were not shown in the Messages panel for the
11668
first item from the measurements result list.

Resolved an issue with a specific board with a large number of duplicate pin-pairs,
11678
which resulted in an access violation during file loading.

Altium Designer no longer freezes after adding a BomDoc to a specific project that
11361
contains a component with modified grouping parameters.
4360 EOleException error no longer occurs during import of certain large Allegro designs.

9181 FSO in Schematic now supports "All project documents" scope. (BC:2410)

Html reports are no longer blocked from being opened, if browser is disabled in
9485
Network Connectivity.

9625 Restored the ability to highlight all nets in a net class covered by a schematic blanket.

Rule Directives attached to components are no longer deleted, when new variant is
9648
selected.

Altium Designer do not crashes anymore, while opening Protel DOS schematic S01
9688
extension files.

From version 16.1, Altium Designer no longer supports Windows XP. You will not
9735
be able to perform an install, or update an installed build.

An issue with the ibis model editor not retaining the selected component model has
9846
been fixed.

Missing Harness Type on Signal Harness compiler error is now generated for each
10168
unconnected Signal Harness.

It is possible now to update a footprint model for a varied component using the
10515
Update from Library command.

11055 Commonly used settings are now used as defaults in Altium Designer.

Resolved an issue where a schematic print preview, launched from the Default Prints
11570
tab of the Project Options dialog, would be blank.

Generate Table of Contents in the advanced options of assembly drawing is now


9260
preserved between sessions.

9282 Improved support for high DPI monitors.