Sie sind auf Seite 1von 4

ANSAL HEI GHT

AT S ECTOR-92, GURGAON
11. B ILL OF QUANT ITIES & EST IMATE
SUMMARY AS ACTUAL BALANCE QTY
As per WO SUPPLY INSTALLATION SUPPLY INSTALLATION
S.No. Description Of Equipments / Materials Unit Qty. Rate Amount Amount Amount Amount Amount

1) Part I Equipment. INR 2081730 18025 18025 2063705 2063705

2) Part II Air Distribution Work. INR 9483850 5246744 4627349 5395575 6007533

3) Part III Electrical Work. INR 2534420 0 0 2534420 2534420

Total Co ntract Price Inclusive of All Taxes & Duties As


Applicable In Haryana. (SERVICE TAX EXTRA) INR 14100000 5264769 4645374 9993700 10605658
BILL OF QUANTITIES & ESTIMATE
As per WO AS ACTUAL BALANCE QTY
SITC SUPPLY INSTALLATION SUPPLY INSTALLATION REMARKS
S.No. Description Of Equipments / Materials Unit Qty. Rate Amount QTY Amount QTY Amount QTY Amount QTY Amount
Part I Equipment.

1) A xial Flow Fa n For B as eme nt Ventila tion, Lift Well


Pr ess ur is ation, S TP, Plumbing Plant R oom etc .

FAN WITH BIRD SC REEN/LOU VER, MOUN TING


A RRA NGEMENT & SILENCER (IF R EQU IR ED) SHALL B E
SU PPLIED BY CLIENT
Su ppl y, instal latio n, testing an d co mmissio nin g o f ce ili ng
mo unted Tub e Axial fl ow fan s with ad ju sta ble p itch bl ad e, MS / GI
l ong casin g (2mm thi ck u p to 80 0 mm di a fan, 3 mm thick from 9 00
to 1 250 mm di a & 4 mm th ick abo ve 13 00 mm di a) , ca st al umin ium
a llo y impe lle r co mple te w ith TEFC Sq. Cag e In du cti on motor
su itabl e fo r 4 15 vo lts ± 1 0%, 5 0Hz ± 3 % , three p hase A.C supp ly
w ith sup port, mo untin gs, vibra ti on i sola to rs, fire retarda nt fl exib le
ca nvass conn ector 150 mm d eep (Inle t & Outle t as re qui red), b ird
scre en (In let & Outle t a s req uire d) etc. & of fol low ing capa city. The
co mple te fan al ong wi th motor sha ll be suitab le fo r 2 50 °C
temp erature rated for 2 hou rs. Fan outle t ve loci ty sh all b e li mited to
ma ximum of 16 m/sec. Fan Dia & Fa n mo to r KW gi ven bel ow are
for gu ide lin e & a ctu al Di a / KW sh all b e as per man ufacturer
se lectio n base d on ma ximum 16 m/sec ou tl et ve lo city.

Axi al Fan shal l be AMC A ce rti fi ed for Air (Mu ltipl e Bla de Ang le) a nd
So und p erforman ce i n accord ance to AMC A 210 a nd AMC A
3 00/30 1. Motors sel ected for thi s app lica ti on sh all be ce rti fi ed
a ccordi ng to stan dard BS EN 1 21 01-3 :2 002 / UL "Po wer Ven ti lators
for Smo ke C ontrol Systems" for 2 50 °C fo r 2 h ours. Co mple te Fan
sh all be te sted a nd app rove d by Exova Warri ngton fi re / Eq uiva len t
Intern ation all y re cogn ized Inde pen de nt Fire Lab oratory in
a ccorda nce wi th BS EN 1 210 1-3 :2 002 / U L "Po wer Ve ntila tors for
Smo ke Con tro l Syste ms".

Ma nufacture r shal l furni sh AMCA Te st C ertificate al on g with fire te st


ce rti fi cate (Latest) fo r each fan so urced from tha t pa rti cula r factory.

A s disc us sed in me eting supply of fans is rem ov ed fr om s cope


of work
1.1 1 7,000 C FM (25 mm st. p r, 800 mm Dia Axia l Fa n, 5 .5 KW, 14 50
R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 1 8870 8870 0 0 0 0
C ase Of Norma l Mode , For B as eme nt Ventilation 1 8870 1 8870

1.2 2 3,000 CFM (2 5mm st. pr, 10 00 mm D ia Axia l Fan , 7.5 KW, 15 40
R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 3 8870 26610 0 0 0 0
C ase Of Norma l Mode , For B as eme nt Ventilation 3 26610 3 26610

1.3 2 5,000 CFM (2 5mm st. pr, 10 00 mm D ia Axia l Fan , 7.5 KW, 14 50
R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 7 8870 62090 0 0 0 0
C ase Of Norma l Mode , For B as eme nt Ventilation
7 62090 7 62090

1.4 2 5,000 CFM (1 7mm st. pr, 10 00 mm D ia Axia l Fan , 7.5 KW, 14 50
R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 1 8870 8870 0 0 0 0
C ase Of Fire Mode, For Bas em ent Ventila tion 1 8870 1 8870

1.5 2 8,000 CFM (25 mm st. p r, 112 0 mm D ia Axia l Fan , 11 .0 KW, 14 50


R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 6 8870 53220 0 0 0 0
C ase Of Norma l Mode 6 53220 6 53220

Part I Equipment.

1.6 3 0,000 C FM (25 mm st. pr, 112 0 mm D ia Axi al Fan, 11 KW, 14 50


R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 3 8870 26610 0 0 0 0
C ase Of Norma l Mode , For B as eme nt Ventilation
3 26610 3 26610

1.7 3 5,000 C FM (17mm st. pr, 12 50 mm D ia Axial Fan, 11 KW, 14 50


R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 3 8870 26610 0 0 0 0
C ase Of Fire Mode, For Bas em ent Ventila tion 3 26610 3 26610

1.8 3 7,500 C FM (17mm st. pr, 12 50 mm D ia Axial Fan, 11 KW, 14 50


R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 7 8870 62090 0 0 0 0
C ase Of Fire Mode, For Bas em ent Ventila tion 7 62090 7 62090

1.9 4 2,000 CFM (1 7mm st. pr, 1 250 mm Di a A xial Fan , 15 KW, 9 60
R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 6 8870 53220 0 0 0 0
C ase Of Fire Mode, For Bas em ent Ventila tion 6 53220 6 53220

1.10 4 5,000 CFM (1 7mm st. pr, 1 250 mm Di a A xial Fan , 15 KW, 9 60
R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In NO 3 8870 26610 0 0 0 0
C ase Of Fire Mode, For Bas em ent Ventila tion 3 26610 3 26610

1.11 1 2,000 CFM (1 7mm st. pr, 7 10 mm Di a Axi al Fan, 3 KW, 14 50 RPM
Fan Mo to r, Dire ct Dri ven ) - Fres h Air Fa n Wor king In Ca se Of Fire NO 12 8870 106440 0 0 0 0
Mode, Lift Well Pr ess ur is ation 12 106440 12 106440

1.12 6 ,0 00 C FM (2 0mm st. pr, 630 mm D ia Axia l Fa n, 1.1 KW, 14 50


R PM Fan Motor, Dire ct D riven ) - Fre sh Air Fan Wor king In Ca se
NO 7 8870 62090 0 0 0 0
Of Fire Mode , 6 N os . Bas em ent Lift Lobby Pre ss ur is ation & 1
N o. STP Fres h Air 7 62090 7 62090

1.13 7 ,0 00 C FM (2 0mm st. pr, 630 mm D ia Axia l Fa n, 1.5 KW, 14 50


R PM Fan Mo tor, D irect D riven ) - Exhaust A ir Fan Work ing In
NO 3 8870 26610 0 0 0 0
C ase Of Norma l Mode, 1 N o. STP Exhaust & 2 N os . for
Plumbing Pump Room Supply & Exha us t) 3 26610 3 26610

1.14 1 0,000 C FM (20 mm st. p r, 710 mm Dia Axia l Fa n, 2 .2 KW, 14 50


R PM Fa n Motor, Dire ct D riven ) - Fr esh Air & Ex ha us t A ir Fa n NO 2 8870 17740 0 0 0 0
Working In Ca se Of N or mal Mode, For Tr ansforme r Room
2 17740 2 17740

Part I Equipment.

2) Factory Fabricated Double Skin Airwasher (DG Room)

Su ppl y, instal latio n, te sti ng a nd commi ssion ing o f factory


fab ricated D oub le Skinn ed Air-wa sher u nit fl oo r mou nted typ e
fab ricated ou t of extrud ed al umin ium section with 0 .6mm
p re-pl asticize d / p re-coa te d Ga lvan ised steel sh eet outsid e & 0.6
mm p lai n Ga lvan ised ste el sh eet in side w ith bl owe r, bl owe r se cti on
a nd blo wer mo to r TEFC (EFF1) type suitab le for o pe ration on
4 15 volts ± 10% , 5 0 H z ± 5 % AC su ppl y, be lt dri ve p ackag e, we t
se cti on & tank sh all b e mad e of 1 8 G tain less steel .-AIR
WASHER DULY ASSEMBLED AT SITE SHAL L BE PROVIDED BY
C LIENT

The Air-w ashe r shal l be co mple te with fill of d ep th 2 00 mm


& fa ce ve loci ty across the fill sh all be l imited to 1 52 MPM.
The Ai r-wash er sha ll ha ve an effi cien cy o f 9 0% & sh all be
co mple te w ith w ater circul ation pu mp GI B Cla ss i nterco nne cti ng
p ipi ng & val ves A lumin um visco us fil te rs. The Air-wa sher sh all
h ave a n effi cie ncy of 9 0% & shal l be co mple te with w ater
ci rcula ti on pu mp GI B Cl ass interco nne cting pi pin g & va lves
Al umin um vi scous filters. The a irwa sher p an els sh all b e
i nsul ated with 23 mm thick & 3 6 Kg/m³ den sity PU foa m. The
Ai rwash er sh all con fo rm to spe cica ti on g iven in the te nde r & sha ll
b e of fol low ing capa city.
AS PER BALAN CE
QTY AN D SITE
2.1 5 0,000 CFM, 2 x 900 mm Dia . Fan , 2 x 1 5 or 1 x 30 Kw Fa n Motor REQUIREMENT.
o r a s re qui red, 50 mm St. Pre ssure, 1 x 2 .0 H P Mo nob loc k Pu mp NO. 2 9000 18000 1 9000 1 9000
1 9000 1 9000

3) Centrifugal Fan

Su ppl y, in sta lla ti on, te sti ng an d commissi oni ng of D ID W


ce ntrifuga l fan, GI con stru cti on. Th e fan sh all be suitab le for V be lt
d rive arra nge ment & in ba re sh aft co nstruction . The fa n
i mpel ler sha ll ha ve ba ckward cu rved b lad es sui ta ble fo r han dli ng
a ir. The ce ntrifuga l fan mo to r shal l be suitab le for si ngl e spe ed
TEFC sq uirre l cag e i ndu cti on motor su itabl e for 4 15 4 15 volts ±
1 0%, 5 0Hz ± 5 %, th ree pha se AC p owe r sup ply mo to r with class
"H " insu latio n, Fi re resistan t V bel t dri ve set co mp risin g of fan &
mo to r pu llys & one set o f bel ts, sl ide rail s, MS / GI b elt p rotection ,
fire rated co nvass co nne ction at outle t si de, mul ti lou vers da mper a t
o utlet sid e in GI co nstructio n with ca sing i n 16 G & l ouve rs i n 18
G con stru cti on, fou nda ti on b olts, co mmon base frame in
stan dard MS con stru cti on, an ti vib ration moun ti ngs arran geme nt.
C ompl ete fa n sha ll be ce rti fi ed for 25 0 °C for 2 ho urs fi re rating . The
fa n cap acity shal l be as foll ows:-V Belt will not be fire re sistant

A s disc us sed in m eeting supply of fans rem ov ed from sc ope


of work
3.1 4 0,000 C FM, 2 5mm st. p r, 1100 mm Dia Fan, 20.0 HP, 9 60 RPM
NO. 2 9025 18050 1 9025 1 9025
Fan Mo to r, Belt Drive n 1 9025 1 9025

Part I Equipment.

4) C O & C O2 Ba sed Sensing Sy stem For Autom ated Working Of


Pa rking Ventilation Fans (Norma l & Fire Mode B oth)

4.1 Su ppl y, in sta lla ti on, testing a nd co mmissio nin g of CO & CO2 ba sed
se nsin g system fo r a utomatic runn ing of p arkin g v entil ation sup ply
a nd e xahu st fan s fo r norma l & fi re mod e op eratio n. Each se t o f Set 20 39850 797000 0 0 0 0
system for ea ch zon e sha ll ha ve two n os. co mbin ed C O & CO2
Se nsor.
20 797000 20 797000
Sensor shall have following measuring range & accuracy:-
C O ( El ectroche mical Type ) - Mini mum mea surin g ra nge : 0 ~ 5 00
p pm, C O2 ( ND IR Type )- Mini mum measu ring ra nge : 0 ~ 50 00
p pm & Accura cy < 1% of measu ring ra ng e.
C overa ge of ea ch se nsor shal l b e 75 00 Sq Ft & two no s sha ll be
p lace d in ea ch zon e
N ormal mod e axia l fan sh all au to matical ly start whe n C O
me asure ment is a bove 30 ppm o r CO2 mea sureme nt is ab ove 9 00
p pm. IF C O le vel rea ches 15 0 pp m the n fa n in fire mod e shou ld
start a utomatica lly. Use r shou ld be abl e to vary the se se tp oin ts
thro ugh HMI / We b b ased softw are interface / supe rvisory
co ntroll er. Lo gic Co ntroll er sha ll al so have the l ogi c to swi tch ON
the no rmal mod e fan w hen CO i s ab ove 30 pp m & switche d OFF
a gai n whe n CO dro ps bel ow 25 p pm.Also it sh oul d switch on the
fan if CO2 is a bo ve 90 0 pp m & switch o ff on ce C O2 leve l rea ches
b elo w 80 0 pp m . Simi larl y fire mo de fan shou ld a lso swi tch ed o n/off
w hen CO l eve l reach es 15 0 pp m & sw itched off wh en p pm rea ches
b elo w 50 . Lo gic C ontrol ler sh all a lso h ave the faci lity of Time r &
Ma nua l Ove rride for fan o pera ti on.

4.2 Su ppl y, instal latio n, te sti ng an d commi ssion ing o f on e no .


Stan dal one Intell ige nt Microp rocesso r base d Prog rammab le D DC
(For Tw o Zo nes) wi th inb uil t HMI , Onb oard Mo db us port & n etwork
fun cti ona litie s base d u pon KNX pro to col a lon g wi th suitab le
En closu res with al l accesso ries in clud ing n ecessa ry sw itchge ar,
step d own tra nsformer, i nterna l pow er and control ca bli ng Set 10 56630 566300 0 0 0 0
(e xclud ing po wer & co ntrol cabl e to Fan), co mple te in a ll respe ct &
a s requ ired to su it th e site co ndi ti ons e tc. Each Set o f D DC
C ontrol ler sho uld h ave 8 DI, 6 D O & modb us port as per IO
Su mmary give n in spe cifica ti on pe r Tw o Zo ne .
10 566300 10 566300

Part I Equipment.

4.3 Supp ly, Instal latio n, Te sti ng a nd C ommissi oni ng o f L ogi c


Supe rvisory Co ntroll ers . Th e Sy ste m sho uld h ave Inbu ilt Gra phi c
Softw are to vie w the Ba semen t Ven ti latio n system in clud ing
Senso rs fe edb ack, Actua l rea din g, Fa n co mma nd and runn ing Lot 1 114700 114700 0 0 0 0
sta tu s throu gh Gra phi c softw are . R efer I-O Summary i n the
speci fi cation .
1 114700 1 114700
The L ogi c Su pe rvisory system shou ld ha ve fo llo win g esse ntial
fea tu res:-

> Inb uil t Graph ic Softw are for Gra ph ical Vie w of Syste m
Pa rameters or we b acce ss o f system on stand ard b rowse r.
> IP Eth ern et N etwork Port fo r Web u ser In te rfa ce
for con nectin g the system over a De skto p or La ptop wi th out th e
re qui remen t of sp eci al software o th er th an b rowse r .
> Sh oul d have BAC net & Mod bu s
i nterface to i nteg rate with BMS

Total of Part I carried to Summary of Prices. 2081730 18025 18025 2063705 2063705

Part II Air Distribution Work.

1) Factory Fabricated GI Duct

Su ppl y, in sta lla ti on, testin g an d commi ssion ing of fa ctory fabri cated
GSS sh eet metal rectan gul ar du cti ng compl ete wi th ne opre ne
ru bbe r gaske ts, el bow s, sp litter da mpe rs , van es, ha nge rs, su ppo rts
e tc. as p er ap prove d dra win gs an d sp ecifica ti ons o f fol low ing shee t
thi ckness comp lete a s re qui red.

1.1 24 G (Up To 750 MM) SMT 940 700 658000 1127 788669 1115 780765 500 350000 500 350000

1.2 22 G (751 MM To 1500 MM) SMT 4140 810 3353400 2506 2029694 2499 2023972 1634 1323706.05 1641 1329428.39625

1.3 20 G (1501 MM To 2250 MM) SMT 2490 960 2390400 1237 1187933 1181 1134158 1253 1202467.2 1309 1256241.696
AS PER BALAN CE
1.4 18 G (Above 2250 MM) SMT 610 1270 774700 669 849198 421 534297 331 420801.8 579 735703.38 QTY & SITE
REQUIREMENT.
2) Site Fabricated GI Duct

Su ppl y, fab ricatio n, i nstall ation & te sting of shee t metal du cti ng
co mple te w ith n eop ren e ru bbe r g askets, e lbo ws, spl itte r d ampe rs,
va nes, h ang ers, supp orts etc. as p er ap prove d d ra win gs a nd
sp ecifica ti ons of foll owi ng she et thi ckness comp le te a s re qui red.

2.1 24 G (Up To 750 MM) SMT 150 670 100500 125 83750 107 71866 175 117250 193 129310

2.2 22 G (751 MM To 1500 MM) SMT 460 820 377200 375 307500 100 82292 185 151700 460 377200

2.3 20 G (1501 MM To 2250 MM) SMT 270 1020 275400 0 0 0 0 270 275400 270 275400
AS PER BALAN CE
2.4 18 G (Above 2250 MM) SMT 220 1170 257400 0 0 0 0 220 257400 220 257400 QTY & SITE
REQUIREMENT.
3) Duct Accoustic Lining

Su ppl ying an d fixi ng of aco ustic l ini ng of du ct with fi bre gla ss rig id
b oard o f de nsity 48 Kg/m³ se ale d in fibre gla ss tissu e pap er and
co vered wi th 0 .5 mm thi ck pe rfo rated alu mini um sh eet a nd
co nformin g to sp eci fi cation g iven i n th e te nd er.

3.1 25 mm thick fibre glass rigid board. SMT 210 610 128100 0 0 0 0 210 128100 210 128100

4) Grilles, Diffusers, VCD

Su ppl y, instal ltion an d te stin g of Po wde r coa te d Alumi niu m


e xtru ded gril ls / di ffuse rs a s per spe cificatio ns gi ve n in ten der
a nd of fo llo win g size s.

4.1 Single louvered supply / return air registers (Grills) SMT 115 3520 404800 0 0 0 0 115 404800 115 404800
AS PER BALAN CE
4.2 Fresh / Exhaust air louvers with bird screen SMT 90 4700 423000 0 0 0 0 90 423000 90 423000 QTY & SITE
REQUIRE ME NT

4.3 Vol ume co ntrol GI Da mpers to be p rovid ed in su ppl y & Exha ust air
SMT 115 2170 249550 0 0 0 0
re gisters / termi nal s. 115 249550 115 249550

5) Duct Damper

5.1 GI vol ume con tro l d uct d ampe r comp lete wi th ne opre ne rub ber
g askets, n uts, bo lts, screw s li nka ges, fla ng es e tc , as per SMT 20 4570 91400 0 0 0 0
sp ecifica ti ons.
20 91400 20 91400

Total of Part II carried to Summary of Prices. 9483850 5246744 4627349 5395575 6007533

Part III Electrical Work.

1) Zonal Vetilation Panel

1.1) For Fan Motor 1 x 5.5 KW + 1 x 7.5 KW Set 1 52110 52110 0 0 0 0 1 52110 1 52110

Su ppl y, in sta lla ti on, testin g a nd commissio ni ng o f Cub ical typ e


se cti nal ised fl oor sta nd ing sw itch b oard b y C PRI a pprve d
firms of 1 8 MVA fau lt ca paci ty a t 415 V comp lete wi th 4 strip,
1 25 A cap acity Alu mini um Bu s - Ba r E lectrol yti c gra de E-91 ,
ca ble all ey, swi tch gea rs suitab le fo r AC-23 du ty & o f fo llo win g
ca paci ty & as p er speci fi cation g iven i n th e tend er.

Incomer

1 00 A TP+N MCC B w ith (0-10 0A) ammeter with th ree CT and


se lector sw itch, (0 - 5 00 V) vol tme te r wi th se lecto r sw itch, ph ase
i ndi cation li ght w ith p rotection with protectio n fuse , on / off
i ndi cating li ght with pro te cti on fuse. SET 01

Outgoing

a) For Fan Motor of 5.5 Kw

4 0 A TPN MCB w ith 25 A DOL starter, o verlo ad re lay, sta rt/stop


p ush b utto ns, amme te r (0-40 A) with thre e CT & sel ector swi tch ,
o n/off/trip ind icatio n lig hts wi th SP MC B, sing le pha se preve nter &
a uto / ma nua l mode se lector sw itch. SET-01

b) For Fan Motor of 7.5 Kw

40 A TPN MCB wi th 16 A Sta r De lta starter, o verlo ad re lay,


sta rt/stop push bu tton s, ammete r (0-40 A) wi th three CT & sele cto r
switch, on /o ff/tri p in dica ti on lig hts with SP MC B, si ngl e p hase
preve nter & a uto / ma nua l mode se le cto r sw itch. SET-01

Controls & interlocking accessories as required. Lot

1.2) For Fan Motor 1 x 7.5 KW + 1 x 11 KW NO. 10 57580 575800 0 0 0 0 10 575800 10 575800

Su ppl y, in sta lla ti on, testin g a nd commissio ni ng o f Cub ical typ e


se cti nal ised fl oor sta nd ing sw itch b oard b y C PRI a pprve d
firms of 1 8 MVA fau lt ca paci ty a t 415 V comp lete wi th 4 strip,
1 25 A cap acity Alu mini um Bu s - Ba r E lectrol yti c gra de E-91 ,
ca ble all ey, swi tch gea rs suitab le fo r AC-23 du ty & o f fo llo win g
ca paci ty & as p er speci fi cation g iven i n th e tend er.

Incomer

1 00 A TP+N MCC B w ith (0-10 0A) ammeter with th ree CT and


se lector sw itch, (0 - 5 00 V) vol tme te r wi th se lecto r sw itch, ph ase
i ndi cation li ght w ith p rotection with protectio n fuse , on / off
i ndi cating li ght with pro te cti on fuse. SET 01

Part III Electrical Work.

Outgoing

a) For Fan Motor of 7.5 Kw

AS PER BALAN CE
QTY & SITE
REQUIREMENT.
ANSAL HEI GHT
AT S ECTOR-92, GURGAON
S.No. Description Of Equipments / Materials Unit Qty. Rate Amount Amount Amount Amount Amount
40 A TPN MCB wi th 16 A Sta r De lta starter, o verlo ad re lay,
sta rt/stop push bu tton s, ammete r (0-40 A) wi th three CT & sele cto r
switch, on /o ff/tri p in dica ti on lig hts with SP MC B, si ngl e p hase
preve nter & a uto / ma nua l mode se le cto r sw itch. SET-01

b) For Fan Motor of 11 Kw

63 A TPN MCB wi th 25 A Sta r De lta starter, o verlo ad re lay,


sta rt/stop push bu tton s, ammete r (0-60 A) wi th three CT & sele cto r
switch, on /o ff/tri p in dica ti on lig hts with SP MC B, si ngl e p hase
preve nter & a uto / ma nua l mode se le cto r sw itch. SET-01

Controls & interlocking accessories as required. Lot

1.3) For Fan Motor 1 x 11 KW + 1 x 15 KW NO. 9 61970 557730 0 0 0 0 9 557730 9 557730

Su ppl y, in sta lla ti on, testin g a nd commissio ni ng o f Cub ical typ e


se cti nal ised fl oor sta nd ing sw itch b oard b y C PRI a pprve d
firms of 1 8 MVA fau lt ca paci ty a t 415 V comp lete wi th 4 strip,
1 60 A cap acity Alu mini um Bu s - Ba r E lectrol yti c gra de E-91 ,
ca ble all ey, swi tch gea rs suitab le fo r AC-23 du ty & o f fo llo win g
ca paci ty & as p er speci fi cation g iven i n th e tend er.

Incomer

1 25 A TP+N MCC B w ith (0-12 5A) ammeter with th ree CT and


se lector sw itch, (0 - 5 00 V) vol tme te r wi th se lecto r sw itch, ph ase
i ndi cation li ght w ith p rotection with protectio n fuse , on / off
i ndi cating li ght with pro te cti on fuse. SET 01

Outgoing

a) For Fan Motor of 11 Kw

63 A TPN MCB wi th 25 A Sta r De lta starter, o verlo ad re lay,


sta rt/stop push bu tton s, ammete r (0-60 A) wi th three CT & sele cto r
switch, on /o ff/tri p in dica ti on lig hts with SP MC B, si ngl e p hase
preve nter & a uto / ma nua l mode se le cto r sw itch. SET-01

b) For Fan Motor of 15 Kw

63 A TPN MCB wi th 32 A Sta r De lta starter, o verlo ad re lay,


sta rt/stop push bu tton s, ammete r (0-60 A) wi th three CT & sele cto r
switch, on /o ff/tri p in dica ti on lig hts with SP MC B, si ngl e p hase
preve nter & a uto / ma nua l mode se le cto r sw itch. SET-01

Controls & interlocking accessories as required. Lot

Part III Electrical Work.

1.4) For DG Room Ventilation Fan Motor 1 x 30 KW + 2 x 15 KW NO. 2 92410 184820 0 0 0 0 2 184820 2 184820

Su ppl y, in sta lla ti on, testin g a nd commissio ni ng o f Cub ical typ e


se cti nal ised fl oor sta nd ing sw itch b oard b y C PRI a pprve d
AS PER BALAN CE
firms of 1 8 MVA fau lt ca paci ty a t 415 V comp lete wi th 4 strip,
3 15 A cap acity Alu mini um Bu s - Ba r E lectrol yti c gra de E-91 , QTY & SITE
ca ble all ey, swi tch gea rs suitab le fo r AC-23 du ty & o f fo llo win g REQUIREMENT.
ca paci ty & as p er speci fi cation g iven i n th e tend er.

Incomer

1 50 A 4 Po le MCC B wi th (0 -150 A) amme te r with thre e CT an d


se lector sw itch, (0 - 5 00 V) vol tme te r wi th se lecto r sw itch, ph ase
i ndi cation li ght w ith p rotection with protectio n fuse , on / off
i ndi cating li ght with pro te cti on fuse. SET 0 1

Outgoing

a) For Fan Motor of 30 Kw

125 A TP+N MCC B with 45 A star d elta sta rte r, ove rloa d re lay,
sta rt/stop p ush b utto ns, ammeter (0 -125 A) with thre e CT & sele cto r
switch, on /o ff/tri p in dica ti on lig hts with SP MC B, si ngl e p hase
preve nter & a uto / ma nua l mode se le cto r sw itch. SET-02

OR

b) For 2 x 15 KW Fan Motor

63 A TPN MCB wi th 32 A Sta r De lta starter, o verlo ad re lay,


sta rt/stop push bu tton s, ammete r (0-60 A) wi th three CT & sele cto r
switch, on /o ff/tri p in dica ti on lig hts with SP MC B, si ngl e p hase
preve nter & a uto / ma nua l mode se le cto r sw itch. SET-02

c) For Air Washer Pump

1 6 A SP MC B, SET-2

Controls & interlocking accessories as required. Lot

2) Electrical Sub Panel for FAN

Su ppl y, i nstall ation , te sting and co mmissio nin g o f C ub ical wa ll


mo unted typ e switch bo ard as detai led b elo w & swi tch g ears
su itabl e for AC - 2 3 d uty in clud ing maki ng interco nne cti on etc as
re qui red.

Part III Electrical Work.

2.1) For Vent Fan Motor Up to 3.73 Kw NO. 23 11270 259210 0 0 0 0 23 259210 23 259210

4 0 A TPN MCB wi th 9 / 12 / 16 A D OL starter, o verlo ad rel ay,


start / stop push bu tton s, pha se i ndi cation lig hts wi th pro te cti on
fuse , on / o ff / tri p in di cation lig hts wi th pro te cti on fuse , sing le
p hase p reve nter & a uto / man ua l mode se lector swi tch .
S et - 01
Controls & interlocking accessories as required. Lot

3) Isolators

3.1 4 0 A 3 po le isol ator switch fo r ven ti latio n fa n w ith sh ee t metal


e nclo sure, rain p rotectio n etc. as req uire d to suit th e site cond ition . NO. 23 2250 51750 0 0 0 0
23 51750 23 51750

4) Power & Control Cabling

Su ppl y, la yin g, testing an d co mmi ssion ing o f po wer a nd con tro l


ca bli ng as per speci fi cation gi ven in th e tend er. Powe r cab lin g o f
XL PE i nsul ated Alu mini um cond uctor armo ured ca ble s of 1.1
KV Gra de incl udi ng cab le en d termi natio n with brass
co mpressi on gl and s & alu mini um l ugs etc as pe r sp ecifica ti on.

A) Power Cabling

i) For Vent Fan Motor

1 x 3C x 4 Sq. mm RMT 60 110 6600 0 0 0 0 60 6600 60 6600

1 x 3C x 6 Sq. mm RMT 660 120 79200 0 0 0 0 660 79200 660 79200

1 x 3C x 10 Sq. mm RMT 590 160 94400 0 0 0 0 590 94400 590 94400

1 x 3C x 16 Sq. mm RMT 150 160 24000 0 0 0 0 150 24000 150 24000

B ) C ontrol ca bling (PVC insulated & PV C s he athed with


Shielding Copper c onductor of 1.1 K V Gr ade c able) From C O
Se ns or to PLC

i) 2C x 1.0 Sq. mm in 20 MM dia MS Conduit. RMT 1540 180 277200 0 0 0 0 1540 277200 1540 277200

4) Earthing Strip / Wires as per specs.

i) Sup ply & la ying o f 4 mm di a. GI wire o r i n recess for lo op


RMT 2500 20 50000 0 0 0 0
e arthin g as req uire d. 2500 50000 2500 50000

ii) Sup ply and la ying o f rub ber mat of size 10 00 mm & 1 2.5 mm
thi ck. RMT 20 3210 64200 0 0 0 0
20 64200 20 64200

Part V Electrical Work.

5) Cable Tray

Su ppl y an d i nstall atio n o f l ad er type 16 G M.S. pe rforated 'U'


sh ape d cha nne l 4 0mm x 2 0mm cabl e tra y o f fol low ing si zes

a) 150 mm wide RMT 750 330 247500 0 0 0 0 750 247500 750 247500

b) 300 mm wide RMT 15 660 9900 0 0 0 0 15 9900 15 9900

NOTE:

The AC contractor sh all provi de fire sh unt rel ay con ta ct i n hi s pan el


w here ver ne cessary a lon g wi th auto / man ual mode sele cto r switch
i n th e ou tg oin g feed er for AH U Fa n, Ve ntila ti on & Pressu rizatio n fan
e tc. to ta ke fire inp ut sig nal (Poten ti al Free Co ntact). Cost sha ll be
i nclu ded i n th e pa nel p rice qu oted b y h im.

Total of Part V carried to Summary of Prices. 2534420 0 0 2534420 2534420

]
ANSAL HEIGHT
AT SECTOR-92, GURGAON

11. BILL OF QUANTITIES & ESTIMATE


As Per WO
SITC
Comulativ 5770 Total Of Comulativ
Unit Qty.
e RA-03 27.09.17 RA-04 e RA-04
S.No. Description Of Equipments / Materials
Part II Air Distribution Work.

1) Factory Fabricated GI Duct

Supply, installation, testing and commissioning of factory fabricated


GSS sheet metal rectangular ducting complete with neoprene
rubber gaskets, elbows, splitter dampers, vanes, hangers, supports
etc. as per approved drawings and specifications of following sheet
thickness complete as required.

1.1 24 G (Up To 750 MM) SMT 940 1027.52 99.15 99.15 1126.67

1.2 22 G (751 MM To 1500 MM) SMT 4140 2165.425 340.365 340.365 2505.79

1.3 20 G (1501 MM To 2250 MM) SMT 2490 1117.835 119.59 119.59 1237.425

1.4 18 G (Above 2250 MM) SMT 610 432.365 236.295 236.295 668.66
PROJECT :- ANSAL HEIGHT GURGAON
Ducting Measurement Factory Fabricated Hand Fabricated
Sr.No. Location Width 1 Height 1 Width 2 Height 2 Length 1 Length 2 Qty Type 24 G 22 G 20 G 18 G 24 G 22 G 20 G 18 G

Zone-5 -
1 1500 500 350 1 Straight 1.40
2 1500 500 900 1 Offset 3.60
3 1250 400 900 1 Offset 2.97
Zone-6 -
4 900 400 900 1 Offset 2.34
5 750 400 1000 1 Offset 2.30
Zone-9 -
6 700 350 1200 1 Offset 2.52
Zone-16 -
7 1050 250 1000 250 225 7 Collar 4.02
Zone-17 -
8 1050 250 1000 250 225 15 Collar 8.61
Zone-18 -
9 1050 250 1000 250 225 15 Collar 8.61
Zone-19 -
10 1050 250 1000 250 225 15 Collar 8.61
Zone-20 -
11 1050 250 1000 250 225 14 Collar 8.03
Zone-11 -
12 1050 250 1000 250 225 14 Collar 8.03
Zone-10 -
13 1050 250 1000 250 225 15 Collar 8.61
Zone-6 -
14 Fresh Air Duct 750 450 1220 19 Straight 55.63
15 750 450 350 1200 2 Elbow 3.72
16 750 450 600 1 Straight 1.44
17 750 450 1 B/o 0.34
Zone-8 -
18 Fresh Air Duct 750 450 1220 11 Straight 32.21
750 450 600
19 200 450 1 Tee 1.71
550 450
20 550 450 1220 4 Straight 9.76
21 550 450 1 B/o 0.25
22 200 450 350 450 1100 1 Tapper 1.60
23 350 450 1220 2 Straight 3.90
24 350 450 1 B/o 0.16
Zone-13 -
25 Fresh Air Duct 650 500 1220 9 Straight 25.25
Zone-14
26 750 450 600 2 Straight 2.88
27 750 450 1220 3 Straight 8.78
28 750 450 1800 1 Offset 4.32
29 750 450 500 450 600 1 Tapper 1.29
30 500 450 1220 3 Straight 6.95
Zone-11 -
31 Under Ramp 1600 450 1220 4 Straight 20.01
32 1600 450 600 1 Straight 2.46

Total (Sqmt) 104.56 0.00 22.47 0.00 60.45 64.82 0.00 0.00