INSTRUCTION BOOK
Customer: “BRODOSPLIT”, Split
Newb. No. : 366
Boiler type: KLNIVIC 1500 kg/h - 7 bar
Factory No ; 20142As
CONTENTS:
Part 1
1.1.
a2
laa
1.4.
1.5.
Part 2
Part 3
Part 4
4.4.
4.5.
OFB - Page
DETAILED DESCRIPTION
Boiler description
Main data
Valves and mountings
Instruments and automatic control devices
outfit
INSTALLATION AND SUPPORT OF BOILER
OPERATION AND MAINTENANCE INSTRUCTIONS
General
Preparation for service
Lighting-up and service
Taking out of service
Draining
Cleaning
Boiling out
Chemical dosing purpose and way
Instruction for feed/boiler water
Defective evaporating elements
Tools and Spare parts
ENCLOSURES
Safety valve
Remote level indicator
Alarm device / BCO device
Boiler water samples cooler
Chemical dosing device
1As
Part 1 DETAILED DESCRIPTION
OFB - Page 2
Boiler description
Marine Auxiliary Oil Fired Boiler,vertical,cylindrical,
with pintubes is designed as rigid and safe in operation,
also simple for manipulation and maintenance. It is made
according to an up-to-date technological process in
compliance with the required regulations and development
achievements in boilermarking industry.
cylindrical furnace is placed in a lower part of the boiler,
cooled by water all around. From the furnace the gaseous
products of combustion flow through a certain number of
vertical evaporating elements installed between the furnace
upper dished end and boiler upper tube plate.
The evaporating element consists of an external bare tube
inside of which is located inner pintube. The pintube is
on its upper end connected to the steam space and on the
lower end to the water space of the boiler.
The boiler shall be completed with: connections for the
valves, instruments and automatic control devices, burner
hole, manholes, inspection cleaning holes, necessary lifting
and fastening lugs . The boiler shall be placed in the
engine room and welded directly to the ship's structure
(platform).
The burnerquarl and furnace bottom are to be covered with
refractory lining, while on its outer side, after all
external surfaces are to be cleaned, the boiler is to be
entirely insulated with matresses of mineral wool, 100 mm
thickness, screened with a steel-net and covered with
galvanized steel sheets.