1 Input data
Channel type; bolt HAC-30 68/250 F; HBC-B 4.6F, M12 x 40 mm
Effective embedment depth hef = 68 mm
Channel specification Length: 250 mm, anchor spacing: 200 mm, projection: 25 mm,
width: bch = 41 mm, height: hch = 26 mm
Material Anchor & Channel: hot-dip galvanized
Channel bolt: hot-dip galvanized
Europ. Tech. Assessment (ETA) ETA-11/0006
Issued I Valid 01/02/2016 | -
Standard Design method SA TS 101:2015
Base material cracked, 40MPa, f'c = 40.0 N/mm2, h = 180 mm
Reinforcement Exist. Reinf.: Widely spaced
No edge reinf. present
Reinf. to control splitting not present
Tolerance data tolerance interval: -200 mm/200 mm
most unfavorable tolerance: 25 mm

2 Overall Result
Design ok! (Maximum utilization: 100%)

3 Geometry

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 2
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:
3.1 Fixtures/Channel bolt groups

Fixture 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 3
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:

4 Load case / Resulting bolt forces


Load case: Design load

4.1 Load distribution


4.1.1 Fixture 1: bolt: HBC-B 4.6F, M12 x 40 mm
Profile: -
Standoff: No standoff
Plate dimensions: 200 mm x 100 mm x 8 mm
Anchorplate design calculated: no
Bolt Ncb,i* [kN] Vcb,i* [kN] Vx [kN] Vy [kN] 1.1 1.2
Tension
1.1 3.250 6.285 0.000 -6.285
1.2 3.250 6.285 0.000 -6.285

4.2 Derivation of forces acting on anchor channels


Ni* = k · A'i · N* [kN]
A'i Ordinate at the position of the anchor i of the loadtriangle with load N and the base length
2li
1
k = n
'
SAi
1
li = 13 · I0.05
y · s0.5 » 298 [mm] ≥ s
Iy = 15349 [mm4]
s = 200 [mm]
Vi* = k · A'i · V* [kN]
Mch* = 0.122 [kNm]

hef = 68

a1 a2

25 200 25
Fixture bolt group

Anchor forces [kN]


Anchor Na,i* [kN] Va,i* [kN]
a1 2.839 -5.490
a2 3.661 -7.080

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 4
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:

5 Verifications
5.1 Verifications for anchor channels under tension loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Anchor 3.661 10.111 37 ok
Connection anchor-channel 3.661 10.111 37 ok
Channel lip 3.250 11.056 30 ok
Channel bolt 3.250 16.850 20 ok
Flexure channel 0.122 0.657 19 ok
Pull-out 3.661 17.800 21 ok
Concrete cone 3.661 12.422 30 ok
Concrete splitting 3.661 15.457 24 ok
Concrete blow-out N/A N/A N/A N/A
Suppl. reinf. - steel N/A N/A N/A N/A
Suppl. reinf. - anchorage N/A N/A N/A N/A

5.1.1 Steel failure (SA TS 101:2015 section 6.3.1)


5.1.1.1 Anchor (Anchor a2, Channel a)
Na* ≤ NRd,s,a = NRk,s,a · f Ms

Na* [kN] NRk,s,a [kN] f Ms NRd,s,a [kN]


3.661 18.200 0.556 10.111

5.1.1.2 Connection between anchor and channel (Anchor a2, Channel a)


Na* ≤ NRd,s,c = NRk,s,c · f Ms,ca

Na* [kN] NRk,s,c [kN] f Ms,ca NRd,s,c [kN]


3.661 18.200 0.556 10.111

5.1.1.3 Local flexure of channel lip (Fixture 1, Channel bolt 1.1, Channel a)
Ncb* ≤ NRd,s,l = NRk,s,l · f Ms,l

NRk,s,l = N0Rk,s,l · y l,N

y l,N = 0.5 · 1 +( scbo


sl,N )
≤ 1.0

scbo [mm] sl,N [mm] y l,N


150 83 1.000
Ncb* [kN] N0Rk,s,l [kN] NRk,s,l [kN] f Ms,l NRd,s,l [kN]
3.250 19.900 19.900 0.556 11.056

5.1.1.4 Channel bolt (Fixture 1, Channel bolt 1.1, Channel a)


Ncb* ≤ NRd,s = NRk,s · f Ms

Ncb* [kN] NRk,s [kN] f Ms NRd,s [kN]


3.250 33.700 0.500 16.850

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 5
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:
5.1.1.5 Flexure of channel (Channel a)
Mch* ≤ MRd,s,flex = MRk,s,flex · f Ms,flex

Mch* [kNm] MRk,s,flex [kNm] f Ms,flex MRd,s,flex [kNm]


0.122 0.755 0.870 0.657

5.1.2 Pull-out failure (Anchor a2, Channel a) (SA TS 101:2015 section 6.3.3 )
Na* ≤ NRd,p = NRk,p · f Mp

NRk,p = k2 · Ah · f'c

Ah [mm2]
89
Na* [kN] k2 f'c [N/mm2] NRk,p [kN] f Mp NRd,p [kN]
3.661 7.5 40.0 26.700 0.667 17.800

5.1.3 Concrete cone (Anchor a2, Channel a) (SA TS 101:2015 section 6.3.2 )
Na* ≤ NRd,c = NRk,c · f Mc

NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N

N0Rk,c = k1 · √f'c · h1.5


ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,N N0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5 · hef

0.5
y ch,c,N,1 = (cc )2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = ( )
c2,2
ccr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 f'c [N/mm2] hef [mm] N0Rk,c [kN]


7.7 40.0 68 27.308
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
200 314 0.855 100 157 0.798
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
175 - 1.000 1.000 1.000
Na* [kN] NRk,c [kN] f Mc NRd,c [kN]
3.661 18.633 0.667 12.422

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 6
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:
5.1.4 Concrete splitting (Anchor a2, Channel a), pull-out relevant (SA TS 101:2015 section 6.3.4 )
Na* ≤ NRd,sp = NRk,sp · f Msp

NRk,sp = N0Rk · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N · y h,sp

N0Rk = min(NRk,p, N0Rk,c) = Min(26.700, 27.308) = NRk,p

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si N
1+ · i
cr,sp N0
i=1

scr,sp = 2 · ccr,sp

0.5
y ch,e,N = (cc ) 1
cr,sp
≤ 1.0

0.5
y ch,c,N,1 = (cc )2,1
cr,sp
≤ 1.0

0.5
y ch,c,N,2 = (cc )2,2
cr,sp
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

( (h ) ) ≤ 2.0
2/3 2/3
y h,sp = (hh )min
≤ max 1.0 ; ef + ccr,sp
hmin

N0Rk [kN] s [mm] scr,sp [mm] y ch,s,N c1 [mm] ccr,sp [mm] y ch,e,N
26.700 200 408 0.780 100 204 0.700
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
175 - 0.926 1.000 1.000
h [mm] hmin [mm] y h,sp
180 80 1.717
Na* [kN] NRk,sp [kN] f Msp NRd,sp [kN]
3.661 23.185 0.667 15.457

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 7
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:
5.2 Verifications for anchor channels under shear loading
Load [kN], [kNm] Resistance [kN], [kNm] Utilization [%] Status
Channel bolt w/o lever arm 6.285 12.096 52 ok
Flexure channel lip w/o lever arm - 6.285 11.056 57 ok
perpendicular
Flexure channel lip w/o lever arm - N/A N/A N/A N/A
longitudinal
Channel bolt with lever arm N/A N/A N/A N/A
Flexure of channel lip w/ lever arm N/A N/A N/A N/A
Anchor - perpendicular 7.080 10.111 71 ok
Anchor - longitudinal N/A N/A N/A N/A
Connection anchor/channel - 7.080 10.111 71 ok
perpendicular
Connection anchor/channel - N/A N/A N/A N/A
longitudinal
Concrete pryout, perpendicular 7.080 24.843 29 ok
Concrete pryout, longitudinal N/A N/A N/A N/A
Concrete edge - perpendicular 7.080 7.852 91 ok
Concrete edge - longitudinal N/A N/A N/A N/A
Suppl. reinf. steel - perpendicular N/A N/A N/A N/A
Suppl. reinf. anchorage - N/A N/A N/A N/A
perpendicular
Suppl. reinf. steel - longitudinal N/A N/A N/A N/A
Suppl. reinf. anchorage - longitudinal N/A N/A N/A N/A

5.2.1 Steel failure (SA TS 101:2015 section 7.3.1)


5.2.1.1 Channel bolt - shear perpendicular and/or longitudinal w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (SA TS
101:2015 section 7.3.1.1, Hilti method based on CEN-TR section 7.2.2.2.1)

Vcb* ≤ VRd,s = VRk,s · f Ms

Vcb* = √(Vcb,y*)2 + (Vcb,x*)2

Vcb* [kN] Vcb,y* [kN] Vcb,x* [kN] VRk,s [kN] f Ms VRd,s [kN]
6.285 6.285 0.000 20.200 0.599 12.096

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 8
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:
5.2.1.2 Local flexure of channel lip - shear perpendicular w/o lever arm (Fixture 1, Channel bolt 1.1, Channel a) (SA TS
101:2015 section 7.3.1.2)

Vcb,y* ≤ VRd,s,l,y = VRk,s,l,y · f Ms,l

VRk,s,l,y = V0Rk,s,l,y · y l,V

y l,V = 0.5 · 1 +( scbo


sl,V,y )
≤ 1.0

scbo [mm] sl,V,y [mm] y l,V


150 83 1.000
Vcb,y* [kN] V0Rk,s,l,y [kN] VRk,s,l,y [kN] f Ms,l VRd,s,l,y [kN]
6.285 23.700 23.700 0.556 11.056

5.2.1.3 Anchor - shear perpendicular (Anchor a2, Channel a) (SA TS 101:2015 section 7.3.1.1)
Va,y* ≤ VRd,s,a,y = VRk,s,a,y · f Ms

Va,y* [kN] VRk,s,a,y [kN] f Ms VRd,s,a,y [kN]


7.080 23.700 0.667 10.111

5.2.1.4 Connection between anchor and channel - shear perpendicular (Anchor a2, Channel a) (SA TS 101:2015 section
7.3.1.1)

Va,y* ≤ VRd,s,c,y = VRk,s,c,y · f Ms,ca

Va,y* [kN] VRk,s,c,y [kN] f Ms,ca VRd,s,c,y [kN]


7.080 23.700 0.556 10.111

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 9
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:
5.2.2 Concrete pry-out failure - shear perpendicular (Anchor a2, Channel a) (SA TS 101:2015 section 7.3.3 )
Va,y* ≤ VRd,cp,y = VRk,cp,y · f Mc

VRk,cp,y = k8 · NRk,c

NRk,c = N0Rk,c · y ch,s,N · y ch,e,N · y ch,c,N,1 · y ch,c,N,2 · y re,N

N0Rk,c = k1 · √f'c · h1.5


ef

1
y ch,s,N = ≤ 1.0
nch,N

S[(1 - s ) ]
1.5
si V
1+ · i
cr,N V0
i=1

scr,N (
= 2 · 2.8 - 1.3 ·
hef
180 )
· hef ≥ 3 · hef

0.5
y ch,e,N = (cc ) 1
cr,N
≤ 1.0

ccr,N (
= 0.5 · scr,N = 2.8 - 1.3 ·
hef
180 )
· hef ≥ 1.5· hef

0.5
y ch,c,N,1 = (cc )
2,1
cr,N
≤ 1.0

0.5
y ch,c,N,2 = (cc )
2,2
cr,N
≤ 1.0

hef
y re,N = 0.5 + ≤ 1.0
200

k1 f'c [N/mm2] hef [mm] N0Rk,c [kN]


7.7 40.0 68 27.308
s [mm] scr,N [mm] y ch,s,N c1 [mm] ccr,N [mm] y ch,e,N
200 314 0.855 100 157 0.798
c2,1 [mm] c2,2 [mm] y ch,c,N,1 y ch,c,N,2 y re,N
175 - 1.000 1.000 1.000
Va,y* [kN] k8 NRk,c [kN] VRk,cp,y [kN] f Mc VRd,cp,y [kN]
7.080 2.0 18.633 37.265 0.667 24.843

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 10
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:
5.2.3 Concrete edge failure - shear perpendicular, direction y- (Anchor a2, Channel a) (SA TS 101:2015 section 7.3.2 )
Va,y* ≤ VRd,c,y = VRk,c,y · f Mc

VRk,c = V0Rk,c · y ch,s,V · y ch,c,V,1 · y ch,c,V,2 · y ch,h,V · y ch,90°,V · y re,V

V0Rk,c = k12 · √f'c · c4/3


1

1
y ch,s,V = ≤ 1.0
nch,V

S[(1 - s ) ]
1.5
si V
1+ · i
cr,V V0
i=1

scr,V = 4 · c1 + 2 · bch

0.5
y ch,c,V,1 = (cc )
2,1
cr,V
≤ 1.0

0.5
y ch,c,V,2 = (cc )
2,2
cr,V
≤ 1.0

ccr,V = 0.5 · scr,V = 2 · c1 + bch

0.5
y ch,h,V = h
h
( )
cr,V
≤ 1.0

hcr,V = 2 · c1 + 2 · hch

k12 f'c [N/mm2] c1 [mm] V0Rk,c [kN]


7.5 40.0 100 22.017
s [mm] scr,V [mm] y ch,s,V
200 483 0.742
c2,1 [mm] c2,2 [mm] ccr,V [mm] y ch,c,V,1 y ch,c,V,2
175 - 241 0.852 1.000
h [mm] hcr,V [mm] y ch,h,V y ch,90°,V y re,V
180 251 0.846 1.000 1.000
Va,y* [kN] VRk,c,y [kN] f Mc VRd,c,y [kN]
7.080 11.779 0.667 7.852

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 11
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:
5.3 Combined tension and shear loads (SA TS 101:2015 section 8, Hilti method based on CEN-TR section 7.3)
Proof of interaction performed independently for steel failure of channel bolt, steel failure of the channel and concrete failure
5.3.1 Channel bolt (Fixture 1, Channel bolt 1.1)
2 2

(NN * ) + (√V ) ≤ 1.000


2
cb cb,y* + Vcb,x* 2
bN+V,s =
Rd,s,cb VRd,s,cb

2
bN,s =(NN * ) = 0.03720
cb
Rd,s,cb
2
=( ) = 0.26999
√V * + V *
cb,y
2
cb,x
2
bV,s
V Rd,s,cb

bN+V,s = (0.03720) + (0.26999) = 0.30719 ≤ 1.000

(Utilization : 31%)

5.3.2 Point of load application - channel lip (Fixture 1, Channel bolt 1.1)
k71 k71 k71
bN+V,la,c = max (NN cb*
Rd,s,l
;
Mch*
MRd,s,flex ) + (VV * ) ≤ (1.0 - (VV * ))
cb,y
Rd,s,l,y
cb,x
Rd,s,l,x

Mch* 2.0
bN,la,c = max (
Ncb*
;
NRd,s,l MRd,s,flex
= 0.08642 )
2.0
bV,la,c,y = (
Vcb,y*
VRd,s,l,y ) = 0.32318
2.0
bV,la,c,x (
= 1.0 - (
Vcb,x*
VRd,s,l,x ))
= 1.00000

bN+V,la,c = 0.08642 + 0.32318 ≤ 1.00000

(Utilization : 41%)

bN,la,c, governing failure mode: Channel lip


bV,la,c,y, governing failure mode: Flexure channel lip w/o lever arm - perpendicular
bV,la,c,x, governing failure mode: N/A

5.3.3 Anchor and connection between anchor and channel (Anchor a2)
k72 k72 k72
bN+V,ac = max (NN * , NN * )
a
Rd,s,a
a
Rd,s,c
+ max (VV a,y*
Rd,s,a,y
,
Va,y*
VRd,s,c,y ) ≤ (1.0 - max(VV a,x*
Rd,s,a,x
,
Va,x*
VRd,s,c,x ))
2.0
bN,ac = max (NN * , NN * ) = 0.13110
a
Rd,s,a
a
Rd,s,c
2.0
= max( ) = 0.49028
V * V *
a,y a,y
bV,ac,y ,
V VRd,s,a,y Rd,s,c,y
2.0
= (1.0 - max( )) = 1.00000
V * V * a,x a,x
bV,ac,x ,
V V Rd,s,a,x Rd,s,c,x

bN+V,ac = 0.13110 + 0.49028 ≤ 1.00000

(Utilization : 63%)

bN,ac, governing failure mode: Anchor


bV,ac,y, governing failure mode: Anchor - perpendicular
bV,ac,x, governing failure mode: N/A

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 12
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:
5.3.4 Concrete anchor (Anchor a2)
a a
bN+V,c = (NN *) + (VV *) ≤ 1.2
a
Rd
a,y
Rd,y

1.0
bN,c =(NN *)
a
Rd
= 0.29473
1.0
=(
V )
V *a,y
bV,c,y = 0.90160
Rd,y

bN+V,c = 0.29473 + 0.90160 + 0.00000 = 1.19633 ≤ 1.2

(Utilization : 100%)

bN,c, governing failure mode: Concrete cone


bV,c,y, governing failure mode: Concrete edge - perpendicular
bV,c,x, governing failure mode: N/A

Remarks and warnings


• Steel-to-steel contact required, according to Annex B4 of ETA-11/0006. Use Hilti locking bolt and nut in combination with
washer according to EN ISO 7089 or EN ISO 7093-1.
• The transfer of the loads acting on the fixture to the supports of the structure shall be considered in the design of the
structure taking account of the requirements of SA TS 101:2015 Appendix D, and the structurally required reinforcement has
to be provided.
• The calculation of the acting forces is based on the simplified assumption of a rigid anchorplate/bracket. The
anchorplate

has to be designed accordingly. The design of the anchorplate/bracket must be done seperatly (outside the
PROFIS software) by the engineer.
• A longitudinal reinforcement should be provided along the edge of the member!
• Existing reinforcement and supplementary reinforcement as a PROFIS input should only be selected if the engineer has
verified the design of the concrete substructure complies with the associated reinforcement requirements contained in SA TS
101:2015 and/or in the relevant concrete standard.
• Any as-built conditions which vary from the PROFIS inputs (e.g., use of alternative product, variations in supplementary
reinforcement or base material, changes in load condition...), renders the PROFIS design invalid and requires recalculation.

Design ok! (Maximum utilization: 100%)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 13
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:

6 Installation data
6.1 Fixture 1
Plate type: - Bolt type: HBC-B 4.6F, M12 x 40 mm
Plate dimensions: 200 mm x 100 mm x 8 mm Bolt length: 40 mm
Profile: - Bolt diameter: 12 mm
Anchorplate design calculated: no Diameter hole: 14 mm
Installation torque: 0.025 kNm

100 100

50

50
1.1 1.2 x
50

50

25 150 25

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.au PROFIS Anchor Channel 1.6.2
Company: Page: 14
Specifier: Project:
Address: Fastening point:
Phone | Fax: | Location | Date: 07/12/2018
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the
principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and
assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures,
and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations
carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you
bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of
the results or suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you
must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by
Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the
current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti
will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable
breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor Channel © 2010 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Das könnte Ihnen auch gefallen