Sie sind auf Seite 1von 86

GENERAL CATALOG

VER.14.2
Awex brand has been existing in the emergency tests
lighting sector since 2002, invariably fulfilling its clearly
defined mission: top-quality state-of-the-art products The research and development works ensure that our
and customer satisfaction. We offer the full range of offer is constantly updated according to development
emergency lighting devices in compliance with all the trends in the industry, and thus we can supply the most
European standards. Within 10 years of our market modern, multifunctional and technologically advanced
presence, we gained the leading position in the industry products.
thanks to the involvement of knowledge, means,
cooperation with best specialists, including research We take care of the environment
facilities, and investments in innovative projects.
Awex means the latest technologies, experienced We offer the environment-friendly products and the
team of designers and engineers, top quality, reliable manufacturing process meets strict EU standards.
equipment, diversity of offer, unique design, unlimited
productivity and unblemished reputation supported Quality Warranty
by references. The biggest award is satisfied and
trusted customers. We also enjoy the recognition of With the aim of fulfilling the company’s mission,
independent experts. We were awarded the title of we implemented the quality management system
the “Export Leader 2006” for our business volume, and according to EN ISO 9001:2008, and the certificate
the Puls Biznesu awarded us twice with the “Business issued by TÜV NORD ensures top quality of design,
Gazelles” prize as one of the most dynamically manufacture, assembly and servicing of emergency
developing companies in Poland. lighting equipment.

Professional Personnel

We employ the best specialists in many different


fields for whom we ensure constant improvement in
qualifications by specialist trainings. The company’s
design department provides flexible design of
individual orders and the team of highly qualified
engineers ensures continuous technological progress
of offered equipment. The use of modern information
flow methods within the company ensures that the
offer and functionality of products is updated on an
ongoing basis. The efficient project management allows
building permanent and trust-based relationships with
customers.

investments

We use the latest world technologies to guarantee


quality, precise workmanship, optimised technological
process, and work ergonomics. We invest time and
means so that every stage of manufacturing our
products contributes to meeting any expectations of
our customers.
table of contents

emergency escape lighting 5 emergency conversion kits 55

AXN  6 NEXT & NEXT AUTOTEST 56


AXP8 NEXT PLUS & NEXT PLUS AUTOTEST 57
LOVATO N 10 LIDER EVG 58
LOVATO P 12 LIDER PLUS & LIDER PLUS AUTOTEST 59
EYE LED round 14 LIN60
EYE LED square 16 LINEX & LINEX AUTOTEST 61
EYE18 UNILED BM 62
INFINITY PO 19 UNILED GU10 63
SPY  20 UNILED UM 64
HELIOS LED 22
HELIOS24 systems67
EMX25
TIGER LED 26 RUBIC UNA 68
TIGER27 RUBIC MINI UNA 69
PANORAMA & PANORAMA LED 28 Central Battery system FZLV 70
OUTDOOR LED 29 Central battery system LPS 72
SQUARE30 Central Battery system CBS 74
Twister31 SMART VISIO PLATFORM 76
HERMETICA32
JOBLED33 additional components 79

emergency exit signS 35 HTR 25 - HEATER WITH THERMOSTAT


FOR LOW TEMPERATURE 80
SK-836 Accessories81
INFINITY B 37 BATTERIES82
INFINITY AC & INFINITY AS 38 pictograms83
INFINITY AD & INFINITY AR 39
TWINS40 Information for readers 84
PLEXI LED 41
ESCAPE & ESCAPE LED 42 Used symbols 84
HELIOS & HELIOS LED 43
HELIOS DS & HELIOS DS LED 44
HELIOS P & HELIOS P LED 45
TIGER & TIGER LED 46
TIGER DS & TIGER DS LED 47
TIGER P & TIGER P LED 48
PANORAMA & PANORAMA LED 49
SCREEN50
SCREEN DS 51
EMX52
QUADRO53
emergency escape lighting

AXN  6
AXP8
LOVATO N 10
LOVATO P 12
EYE LED round 14
EYE LED square 16
EYE18
INFINITY PO 19
SPY  20
HELIOS LED 22
HELIOS24
EMX25
TIGER LED 26
TIGER27
PANORAMA & PANORAMA LED 28
OUTDOOR LED 29
SQUARE30
Twister31
HERMETICA32
JOBLED33

AXN AXP LOVATO N LOVATO P EYE LED EYE LED EYE


round square

SPY INFINITY PO HELIOS LED HELIOS EMX TIGER LED TIGER

PANORAMA OUTDOOR LED SQUARE Twister HERMETICA JOBLED


& PANORAM LED
Emergency escape lighting
AXN

MATERIALS:
White polycarbonate body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (118lm), C 1W (114lm) or
O 3W (283lm), C 3W (287lm) or
O 6W (575lm), C 6W (600lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h or 8h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:

202
IP42 or IP65
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 202 58
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery 220-240V
216V 24V
ADDITIONAL INFORMATION: AC LED IP65
DC DC
50-60Hz
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version Ni-MH
Optional adaptation of the fixture for low temperatures up to -25°C

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION
AXNC 1 3 6 1 2 3 8* SE SA AT RS
AXNO 1 3 6 1 2 3 8* SE SA AT RS
AXENC 1 3 6 1 2 3 8* SE SA AT RS
AXENO 1 3 6 1 2 3 8* SE SA AT RS
*AVAILABLE WITH 1W VERSION ONLY

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION
AXNC 1 3 6 CB CBS ADS ADL
Legend:
AXNO 1 3 6 CB CBS ADS ADL SE – non maintained
AXENC 1 3 6 CB CBS ADS ADL SA – maintained
AXENO 1 3 6 CB CBS ADS ADL AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
FZLV SYSTEM CONFIGURATION CBS – central battery (circuit monitoring)
CODE POWER [W] SYSTEM ADS – central battery with address module ADS 20
AXNC 1 3 6 FZLV ADL – central battery with address module ADL
AXNO – fixture AXN IP65 with optics for open area
AXNO 1 3 6 FZLV
AXNC – fixture AXN IP65 with optics for escape route
AXENC 1 3 6 FZLV AXENO – fixture AXN IP42 with optics for open area
AXENO 1 3 6 FZLV AXENC – fixture AXN IP42 with optics for escape route

6
Emergency escape lighting
Photometry

L1 L2

L1 – distance from the wall to the first fixture


L2 – distance between fixtures
h – height of the ceiling

AXNC – LED 1W (114lm) with optics for escape route AXNO – LED 1W (118lm) with optics for open area

AXNC 1W – avg 1lx AXNO 1W – min 0,5lx

h [m] L1 L2 h [m] L1 L2

2,50 6,50 13,00 2,50 3,00 12,00


3,00 6,50 15,00 3,00 3,00 12,00
3,50 6,50 15,00 3,50 3,00 12,00
4,00 6,50 16,00 4,00 3,00 12,00
4,50 5,50 16,00 4,50 3,00 12,00
5,00 5,50 15,00 5,00 3,00 11,50
6,00 5,50 9,00 6,00 2,50 10,50
7,00 5,50 6,00 7,00 2,00 9,00
8,00 5,50 6,00 8,00 2,00 8,00

AXNC – LED 3W (287lm) with optics for escape route AXNO – LED 3W (283lm) with optics for open area
AXNC 3W – avg 1lx AXNO 3W – min 0,5lx
h [m] L1 L2 h [m] L1 L2
2,50 7,00 18,00 2,50 4,00 16,00
3,00 8,00 20,00 3,00 5,00 17,00
3,50 9,00 21,00 3,50 5,00 17,00
4,00 9,50 22,00 4,00 5,00 17,50
4,50 10,00 23,00 4,50 5,00 17,50
5,00 10,50 24,00 5,00 5,00 17,50
6,00 11,00 25,00 6,00 5,00 18,00
7,00 10,50 27,00 7,00 5,00 18,00
8,00 9,50 25,00 8,00 5,00 18,00
9,00 9,00 23,00 9,00 5,00 18,00
10,00 7,00 19,00 10,00 4,00 17,00

AXNC – LED 6W (600lm) with optics for escape route AXNO – LED 6W (575lm) with optics for open area
AXNC 6W – avg 1lx (SE mode) AXNO 6W – min 0,5lx (SE mode)
h [m] L1 L2 h [m] L1 L2
2,50 11,00 24,00 2,50 8,00 18,00
3,00 12,00 26,00 3,00 8,00 20,00
3,50 12,50 27,00 3,50 8,00 21,00
4,00 12,50 29,00 4,00 8,00 22,00
4,50 13,00 30,00 4,50 8,00 23,00
5,00 13,50 31,00 5,00 8,00 23,50
6,00 14,50 33,00 6,00 8,00 24,00
7,00 15,00 34,00 7,00 8,00 24,00
8,00 15,50 36,00 8,00 8,00 25,00
9,00 15,50 37,00 9,00 8,00 25,00
10,00 15,50 38,00 10,00 8,00 25,00
11,00 13,50 39,00 11,00 8,00 25,00
12,00 12,50 39,00 12,00 7,00 25,00

7
Emergency escape lighting
AXP

MATERIALS:
White polycarbonate body
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (118lm), C 1W (109lm) or
O 3W (285lm), C 3W (265lm) or
O 6W (616lm), C 6W (523lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h or 8h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:

100
IP20 or IP65/20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 100 37
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery 220-240V
216V 24V
ADDITIONAL INFORMATION: AC LED IP20 IP65/20
DC DC
50-60Hz
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version Ni-MH

Dimension of assembly hole Ø 80mm

h min. 150 mm
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION
AXPC 1 3 6 1 2 3 8* SE SA AT RS
AXPO 1 3 6 1 2 3 8* SE SA AT RS
AXEPC 1 3 6 1 2 3 8* SE SA AT RS
AXEPO 1 3 6 1 2 3 8* SE SA AT RS
*AVAILABLE WITH 1W VERSION ONLY

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION
AXPC 1 3 6 CB CBS ADS ADL
Legend:
AXPO 1 3 6 CB CBS ADS ADL SE – non maintained
AXEPC 1 3 6 CB CBS ADS ADL SA – maintained
AXEPO 1 3 6 CB CBS ADS ADL AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
FZLV SYSTEM CONFIGURATION CBS – central battery (circuit monitoring)
CODE POWER [W] SYSTEM ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
AXPC 1 3 6 FZLV
AXPO – fixture AXP IP65/20 with optics for open area
AXPO 1 3 6 FZLV
AXPC – fixture AXP IP65/20 with optics for escape route
AXEPC 1 3 6 FZLV AXEPO – fixture AXP IP20 with optics for open area
AXEPO 1 3 6 FZLV AXEPC – fixture AXP IP20 with optics for escape route

8
Emergency escape lighting
Photometry

L1 L2

L1 – distance from the wall to the first fixture


L2 – distance between fixtures
h – height of the ceiling

AXPC – LED 1W (109lm) with optics for escape route AXPO – LED 1W (118lm) with optics for open area
AXPC 1W – avg 1lx AXPO 1W – min 0,5lx
h [m] L1 L2 h [m] L1 L2
2,50 6,00 13,00 2,50 4,00 11,00
3,00 6,00 14,50 3,00 3,00 12,00
3,50 6,50 15,00 3,50 3,00 12,00
4,00 6,50 15,00 4,00 3,00 12,00
4,50 6,50 16,00 4,50 3,00 12,00
5,00 6,50 16,00 5,00 3,00 12,00
6,00 5,50 9,00 6,00 3,00 11,50
7,00 5,50 6,00 7,00 2,50 10,00
8,00 5,50 6,00 8,00 2,00 9,00

AXPC – LED 3W (265lm) with optics for escape route AXPO – LED 3W (285lm) with optics for open area

AXPC 3W – avg 1lx AXPO 3W – min 0,5lx


h [m] L1 L2 h [m] L1 L2
2,50 8,00 18,00 2,50 8,00 15,50
3,00 8,50 19,00 3,00 7,00 17,00
3,50 9,00 20,00 3,50 6,50 17,00
4,00 9,00 23,00 4,00 6,50 17,50
4,50 9,50 23,00 4,50 6,00 18,50
5,00 9,50 23,00 5,00 6,00 18,00
6,00 9,50 24,00 6,00 6,00 18,00
7,00 10,50 24,00 7,00 5,50 18,00
8,00 10,50 24,00 8,00 5,00 18,00
9,00 9,00 22,00 9,00 4,00 18,00
10,00 8,00 17,00 10,00 3,00 18,00

AXPC – LED 6W (523lm) with optics for escape route AXPO – LED 6W (616lm) with optics for open area
AXPC 6W – avg 1lx (SE mode) AXPO 6W – min 0,5lx (SE mode)

h [m] L1 L2 h [m] L1 L2

2,50 10,50 22,00 2,50 8,00 19,50


3,00 10,50 23,00 3,00 8,50 21,50
3,50 12,00 26,00 3,50 9,00 23,00
4,00 12,50 29,00 4,00 9,00 24,00
4,50 13,00 29,00 4,50 9,00 25,00
5,00 13,50 31,00 5,00 8,00 26,00
6,00 14,50 32,00 6,00 8,00 27,00
7,00 15,00 34,00 7,00 8,00 27,00
8,00 15,50 36,00 8,00 8,00 27,00
9,00 15,50 37,00 9,00 7,00 27,00
10,00 15,50 38,00 10,00 7,00 27,00
11,00 13,50 37,00 11,00 7,00 26,00
12,00 12,50 39,00 12,00 7,00 25,00

9
Emergency escape lighting
LOVATO N

MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (118lm), C 1W (114lm) or
O 3W (249lm), C 3W (238lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:

120
IP41

120
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
AT – autotest 120 40
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: 220-240V
216V 24V
LED indicator signalizes mains power supply and battery charge AC LED IP41
DC DC
50-60Hz
Deep discharge protection
III class of insulation of FZLV version
Ni-MH

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
LVNC 1 3 1 2 3 SE SA AT RS WH GR BL
LVNO 1 3 1 2 3 SE SA AT RS WH GR BL
Legend:
SE – non maintained
SA – maintained
CENTRAL BATTERY CONFIGURATION AT – autotest
RS – Rubic central monitoring
CODE POWER [W] SYSTEM OPTION COLOR
FZLV – fixture for central battery FZLV 24 VDC
LVNC 1 3 CB CBS ADS ADL WH GR BL
CB – central battery
LVNO 1 3 CB CBS ADS ADL WH GR BL CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
FZLV SYSTEM CONFIGURATION LVNO – fixture Lovato N with optics for open area
LVNC – fixture Lovato N with optics for escape route
CODE POWER [W] SYSTEM COLOR
WH – fixture in white color
LVNC 1 3 FZLV WH GR BL
GR – fixture in grey color
LVNO 1 3 FZLV WH GR BL BL – fixture in black color

10
Emergency escape lighting
LVNC – LED 1W (114lm) with optics for escape route

LVNC 1W – avg 1lx


h [m] L1 L2
2,50 5,00 11,50
3,00 4,00 12,00
3,50 4,00 14,00
4,00 3,00 14.00
4,50 3,00 14,00
5,00 3,00 13,00
6,00 3,50 12,00
7,00 4,00 11,00

LVNC – LED 3W (238lm) with optics for escape route Photometry

LVNC 3W – avg 1lx L1 L2


h [m] L1 L2
2,50 7,50 16,50
3,00 8,50 18,50 h
3,50 9,00 21,00
4,00 9,00 22,50
4,50 9,50 22,50 L1 – distance from the wall to the first fixture
5,00 10,00 23,00 L2 – distance between fixtures
6,00 11,00 25,00 h – height of the ceiling
7,00 11,00 24,00
8,00 10,00 21,00

LVNO – LED 1W (118lm) with optics for open area

LVNO 1W – min 0,5lx


h [m] L1 L2
2,50 4,50 10,00
3,00 4,00 11,00
3,50 3,50 12,00
4,00 3,00 13,00
4,50 2,50 13,00
5,00 2,00 13,00
6,00 2,00 12,00
7,00 2,00 12,00
8,00 2,00 10,00

LVNO – LED 3W (249lm) with optics for open area

LVNO 3W – min 0,5lx


h [m] L1 L2
2,50 5,00 11,50
3,00 6,00 12,50
3,50 6,50 14,00
4,00 7,50 15,50
4,50 5,50 17,00
5,00 3,50 18,00
6,00 3,00 18,00
7,00 3,00 17,00
8,00 3,00 17,00

11
Emergency escape lighting
LOVATO P

MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (121lm), C 1W (122lm) or
O 3W (242lm), C 3W (238lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP20

95
95
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
95 47,7
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: 220-240V
216V 24V
LED indicator signalizes mains power supply and battery charge AC LED IP20
DC DC
50-60Hz
Deep discharge protection
III class of insulation of FZLV version
Ni-MH

Dimension of assembly hole Ø 80mm

h min. 150 mm

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
LVPC 1 3 1 2 3 SE SA AT RS WH GR BL
LVPO 1 3 1 2 3 SE SA AT RS WH GR BL Legend:
SE – non maintained
SA – maintained
CENTRAL BATTERY CONFIGURATION AT – autotest
RS – Rubic central monitoring
CODE POWER [W] SYSTEM OPTION COLOR
FZLV – fixture for central battery FZLV 24 VDC
LVPC 1 3 CB CBS ADS ADL WH GR BL CB – central battery
LVPO 1 3 CB CBS ADS ADL WH GR BL CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
FZLV SYSTEM CONFIGURATION LVPO – fixture Lovato P with optics for open area
LVPC – fixture Lovato P with optics for escape route
CODE POWER [W] SYSTEM COLOR
WH – fixture in white color
LVPC 1 3 FZLV WH GR BL GR – fixture in grey color
LVPO 1 3 FZLV WH GR BL BL – fixture in black color

12
Emergency escape lighting
LVPC – LED 1W (122lm) with optics for escape route

LVPC 1W – avg 1lx


h [m] L1 L2
2,50 6,50 14,00
3,00 6,50 15,50
3,50 7,00 17,00
4,00 7,00 17,50
4,50 7,50 18,00
5,00 7,00 17,50
6,00 6,00 10,00
7,00 5,00 9,00
8,00 5,00 8,00

LVPC – LED 3W (238lm) with optics for escape route

Photometry
LVPC 3W – avg 1lx
h [m] L1 L2 L1 L2
2,50 7,50 16,50
3,00 8,50 18,50
h
3,50 9,00 21,00
4,00 9,00 22,50
4,50 9,50 22,50
5,00 10,00 23,00 L1 – distance from the wall to the first fixture
6,00 11,00 25,00 L2 – distance between fixtures
7,00 11,00 24,00 h – height of the ceiling
8,00 10,00 21,00

LVPO – LED 1W (121lm) with optics for open area

LVPO 1W – min 0,5lx


h [m] L1 L2
2,50 4,50 10,00
3,00 4,00 11,00
3,50 3,50 12,00
4,00 3,00 13,00
4,50 2,50 13,00
5,00 2,00 13,00
6,00 2,00 12,00
7,00 2,00 12,00
8,00 2,00 10,00

LVPO – LED 3W (242lm) with optics for open area

LVPO 3W – min 0,5lx


h [m] L1 L2
2,50 5,00 11,50
3,00 6,00 12,50
3,50 6,50 14,00
4,00 7,50 15,50
4,50 5,50 17,00
5,00 3,50 18,00
6,00 3,00 18,00
7,00 3,00 17,00
8,00 3,00 17,00

13
Emergency escape lighting
EYE LED round

MATERIALS:
Body made of stainless steel or steel painted white,
other colors optionally
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (117 lm), C 1W (110 lm) or
O 3W (259 lm), C 3W (241 lm) or
3x1W (255 lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:

47
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS: 80 80
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 220-240V
216V 24V
CB – central battery AC LED IP20
DC DC
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection Ni-MH
III class of insulation of FZLV version

Dimension of assembly hole Ø 60mm

h min. 150 mm

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
EYO 1 3 1 2 3 SE SA AT RS ST WH
EYC 1 3 1 2 3 SE SA AT RS ST WH
EY 3x1 1 2 3 SE SA AT RS ST WH

Legend:
SE – non maintained
CENTRAL BATTERY CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM OPTION COLOR
AT – autotest
EYO 1 3 CB CBS ADS ADL ST WH RS – Rubic central monitoring
EYC 1 3 CB CBS ADS ADL ST WH FZLV – fixture for central battery FZLV 24 VDC
EY 3x1 CB CBS ADS ADL ST WH CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
FZLV SYSTEM CONFIGURATION ADL – central battery with address module ADL
EYO – fixture Eye led with optics for open area
CODE POWER [W] SYSTEM COLOR
EYC – fixture Eye led with optics for escape route
EYO 1 3 FZLV ST WH
EY – fixture Eye led
EYC 1 3 FZLV ST WH ST – stainless steel
EY 3x1 FZLV ST WH WH – fixture in white color

14
Emergency escape lighting
EYO – LED 1W (117lm) with optics for open area

EYO 1W – min 0,5lx


h [m] L1 L2
2,50 3,00 9,00
3,00 3,00 10,00
3,50 3,00 11,00
4,00 3,00 11,00
4,50 3,00 11,00
5,00 3,00 11,00
6,00 3,00 10,00
7,00 3,00 8,00
8,00 3,00 6,00

EYO – LED 3W (259lm) with optics for open area

EYO 3W – min 0,5lx


h [m] L1 L2
2,50 5,00 16,00
3,00 5,00 16,00
3,50 5,00 16,00
4,00 5,00 17,00
4,50 5,00 17,00
5,00 5,00 16,00
6,00 5,00 16,00
7,00 5,00 16,00
Photometry
8,00 4,00 15,00
L1 L2

h
EYC – LED 1W (110lm) with optics for escape route

EYC 1W – avg 1lx


L1 – distance from the wall to the first fixture
h [m] L1 L2
L2 – distance between fixtures
2,50 6,00 14,00 h – height of the ceiling
3,00 6,00 15,00
3,50 6,00 15,50
4,00 6,00 16,00
4,50 6,00 16,00
5,00 5,00 13,00
6,00 4,00 10,00
7,00 4,00 8,00
8,00 3,00 6,00

EYC – LED 3W (241lm) with optics for escape route

EYC 3W – avg 1lx


h [m] L1 L2
2,50 7,00 17,00
3,00 8,00 18,00
3,50 8,50 19,50
4,00 9,00 20,50
4,50 9,50 21,50
5,00 10,00 23,00
6,00 10,50 24,50
7,00 10,00 22,00
8,00 7,00 16,00

15
Emergency escape lighting
EYE LED square

MATERIALS:
Body made of stainless steel or steel painted white
other colors optionally
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (117 lm), C 1W (110 lm) or
O 3W (259 lm), C 3W (241 lm) or
3x1W (255 lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:

47
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS: 80 80
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 220-240V
216V 24V
CB – central battery AC LED IP20
DC DC
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection Ni-MH
III class of insulation of FZLV version

Dimension of assembly hole Ø 60mm

h min. 150 mm

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
EYKO 1 3 1 2 3 SE SA AT RS ST WH
EYKC 1 3 1 2 3 SE SA AT RS ST WH
EYK 3x1 1 2 3 SE SA AT RS ST WH

Legend:
SE – non maintained
CENTRAL BATTERY CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM OPTION COLOR
AT – autotest
EYKO 1 3 CB CBS ADS ADL ST WH RS – Rubic central monitoring
EYKC 1 3 CB CBS ADS ADL ST WH FZLV – fixture for central battery FZLV 24 VDC
EYK 3x1 CB CBS ADS ADL ST WH CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
FZLV SYSTEM CONFIGURATION ADL – central battery with address module ADL
EYKO – fixture Eye led square with optics for open area
CODE POWER [W] SYSTEM COLOR
EYKC – fixture Eye led square with optics for escape route
EYKO 1 3 FZLV ST WH
EYK – fixture Eye led square
EYKC 1 3 FZLV ST WH ST – stainless steel
EYK 3x1 FZLV ST WH WH – fixture in white color

16
Emergency escape lighting
EYKO – LED 1W (117lm) with optics for open area

EYKO 1W – min 0,5lx


h [m] L1 L2
2,50 3,00 9,00
3,00 3,00 10,00
3,50 3,00 11,00
4,00 3,00 11,00
4,50 3,00 11,00
5,00 3,00 11,00
6,00 3,00 10,00
7,00 3,00 8,00
8,00 3,00 6,00

EYKO – LED 3W (259lm) with optics for open area

EYKO 3W – min 0,5lx


h [m] L1 L2
2,50 5,00 16,00
3,00 5,00 16,00
3,50 5,00 16,00
4,00 5,00 17,00
4,50 5,00 16,00
5,00 5,00 16,00
6,00 5,00 16,00
7,00 5,00 16,00
Photometry

8,00 4,00 15,00


L1 L2

h
EYKC – LED 1W (110lm) with optics for escape route

EYKC 1W – avg 1lx


L1 – distance from the wall to the first fixture
h [m] L1 L2
L2 – distance between fixtures
2,50 6,00 14,00 h – height of the ceiling
3,00 6,00 15,00
3,50 6,00 15,50
4,00 6,00 16,00
4,50 6,00 16,00
5,00 5,00 13,00
6,00 4,00 10,00
7,00 4,00 8,00
8,00 3,00 6,00

EYKC – LED 3W (241lm) with optics for escape route

EYKC 3W – avg 1lx


h [m] L1 L2
2,50 7,00 17,00
3,00 8,00 18,00
3,50 8,50 19,50
4,00 9,00 20,50
4,50 9,50 21,50
5,00 10,00 23,00
6,00 10,50 24,50
7,00 10,00 22,00
8,00 7,00 16,00

17
Emergency escape lighting
EYE

MATERIALS:
Body made of stainless steel or steel painted white,
other colors optionally
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3x1W (255 lm) power LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP44/20

47
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained 95 95
SA – maintained
AT – autotest
RS – Rubic central monitoring 220-240V
216V 24V IP44/20
AC LED
FZLV – central battery FZLV 24V DC DC
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge Ni-MH
Deep discharge protection
III class of insulation of FZLV version
Dimension of assembly hole Ø 60mm
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
4EY 3x1 1 2 3 SE SA AT RS ST WH
h min. 150 mm
CENTRAL BATTERY CONFIGURATION
CODE POWER [W] SYSTEM OPTION COLOR

4EY 3x1 CB CBS ADS ADL ST WH


4EY – LED 3x1W (255lm)
FZLV SYSTEM CONFIGURATION
CODE POWER [W] SYSTEM COLOR
4EY 3x1 FZLV ST WH

Legend:
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
4EY – fixture Eye
ST – stainless steel 4EY – min 0,5lx open area 4EY – avg 1lx escape route
WH – fixture in white color h [m] L1 L2 h [m] L1 L2

Photometry 2,50 4,00 8,50 2,50 4,50 9,50


3,00 4,00 9,50 3,00 4,50 10,50
L1 L2
3,50 5,00 10,50 3,50 4,50 11,00
4,00 5,00 11,50 4,00 4,50 11,50

h 4,50 5,00 12,50 4,50 5,00 12,50


5,00 5,00 13,50 5,00 5,50 12,50
6,00 5,00 14,50 6,00 5,50 13,00
L1 – distance from the wall to the first fixture
7,00 5,00 16,00 7,00 5,00 13,00
L2 – distance between fixtures
8,00 5,00 17,00 8,00 5,00 13,00
h – height of the ceiling

18
Emergency escape lighting
INFINITY PO

MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3x1W (227 lm) power LED
Open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:

70
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
II 330 45
IP RATING:
IP44
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS: 220-240V
216V 24V
AC LED IP44
SE – non maintained DC DC
50-60Hz
SA – maintained
PT – manual test button
AT – autotest Ni-MH
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: Photometry
LED indicator signalizes mains power supply and battery charge
Deep discharge protection L1 L2
III class of insulation of FZLV version

h
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
IFAPO 3x1 1 2 3 SE SA PT AT RS WH GR BL
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
CENTRAL BATTERY CONFIGURATION
h – height of the ceiling
CODE POWER [W] SYSTEM OPTION COLOR
IFAPO 3x1 CB CBS ADS ADL WH GR BL IFAPO 3x1W (227lm)

BZ7 =100%
135° 150° 180° 150° 135°
FZLV SYSTEM CONFIGURATION 320
CODE POWER [W] SYSTEM COLOR 120° 120°
160
IFAPO 3x1 FZLV WH GR BL 105° 105°

90° 90°

75° 75°
160
60° 60°
320

45° 45°
480
Legend: 30° 15° 0° 15° 30°
SE – non maintained I(0°)=127cd/klm[ cd/klm]
SA – maintained C0-C180 C90-C270

PT – manual test button


AT – autotest
RS – Rubic central monitoring IFAPO – avg 1lx escape route IFAPO – min 0,5lx open area
FZLV – fixture for central battery FZLV 24 VDC
h [m] L1 L2 h [m] L1 L2
CB – central battery
CBS – central battery (circuit monitoring) 2,50 4,00 11,00 2,50 5,00 14,00
ADS – central battery with address module ADS 20 3,00 4,00 11,00 3,00 5,00 15,00
ADL – central battery with address module ADL 3,50 4,00 11,00 3,50 5,00 16,00
IFAPO – fixture Infinity PO 4,00 3,50 10,50 5,00 16,00
4,00
WH – fixture in white color
4,50 3,50 10,00 4,50 4,00 16,00
GR – fixture in grey color
5,00 3,00 8,00 5,00 4,00 16,00
BL – fixture in black color

19
Emergency escape lighting
SPY

MATERIALS:
Body made of aluminum or aluminum painted white
MOUNTING:
Inside light fitting
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (117 lm), C 1W (110 lm) or
O 3W (259 lm), C 3W (241 lm)
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:

63
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C 63 50 - 82 10
OPTIONS:
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
220-240V
216V 24V
SPO 1 3 1 2 3 SE SA AT RS WH SR AC LED IP20
DC DC
50-60H
SPC 1 3 1 2 3 SE SA AT RS WH SR

Ni-MH
CENTRAL BATTERY CONFIGURATION
CODE POWER [W] SYSTEM OPTION COLOR

SPO 1 3 CB CBS ADS ADL WH SR

SPC 1 3 CB CBS ADS ADL WH SR

FZLV SYSTEM CONFIGURATION


CODE POWER [W] SYSTEM COLOR
SPO 1 3 FZLV WH SR
SPC 1 3 FZLV WH SR

Legend:
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
SPO – fixture SPY with optics for open area
SPC – fixture SPY with optics for escape route
WH – fixture in white color
SR – fixture in silver color

20
Emergency escape lighting
SPO – LED 1W (117lm) with optics for open area

SPO 1W – min 0,5lx


h [m] L1 L2
2,50 3,00 9,00
3,00 3,00 10,00
3,50 3,00 11,00
4,00 3,00 11,00
4,50 3,00 11,00
5,00 3,00 11,00
6,00 3,00 10,00
7,00 3,00 8,00
8,00 3,00 6,00

Photometry

L1 L2
SPO – LED 3W (259lm) with optics for open area

SPO 3W – min 0,5lx


h
h [m] L1 L2
2,50 5,00 16,00
3,00 5,00 16,00
3,50 5,00 16,00
L1 – distance from the wall to the first fixture
4,00 5,00 17,00
L2 – distance between fixtures
4,50 5,00 17,00 h – height of the ceiling
5,00 5,00 16,00
6,00 5,00 16,00
7,00 5,00 16,00
8,00 4,00 15,00

SPC – LED 1W (110lm) with optics for escape route

SPC 1W – avg 1lx


h [m] L1 L2
2,50 6,00 14,00
3,00 6,00 15,00
3,50 6,00 15,50
4,00 6,00 16,00
4,50 6,00 16,00
5,00 5,00 13,00
6,00 4,00 10,00
7,00 4,00 8,00
8,00 3,00 6,00

SPC – LED 3W (241lm) with optics for escape route

SPC 3W – avg 1lx


h [m] L1 L2
2,50 7,00 17,00
3,00 8,00 18,00
3,50 8,50 19,50
4,00 9,00 20,50
4,50 9,50 21,50
5,00 10,00 23,00
6,00 10,50 24,50
7,00 10,00 22,00
8,00 7,00 16,00

21
Emergency escape lighting
HELIOS LED

MATERIALS:
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optional assembly with wall or ceiling bracket
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3,2W (257 lm) LED
3x1W (275 lm) or 2x3W (436 lm) power LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP42 or IP65

136
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 356 79
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 220-240V
216V 24V
CB – central battery AC LED IP42 IP65
DC DC
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection Ni-MH
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COVER
HWM HWEM 3,2 1 2 3 SE SA PT AT RS TR OP
Legend:
HWD HWED 3x1 1 2 3 SE SA PT AT RS TR SE – non maintained
HSP HESP 2x3 1 2 3 SE PT AT RS TR SA – maintained
PT – manual test button
AT – autotest
CENTRAL BATTERY CONFIGURATION RS – Rubic central monitoring
CODE POWER [W] SYSTEM OPTION COVER FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
HWM HWEM 3,2 CB CBS ADS ADL TR OP
CBS – central battery (circuit monitoring)
HWD HWED 3x1 CB CBS ADS ADL TR ADS – central battery with address module ADS 20
HSP HESP 2x3 CB CBS ADS ADL TR ADL – central battery with address module ADL
HWM – fixture Helios IP65, assembly altitudes: 2,5 – 10 m
HWD – fixture Helios IP65, assembly altitudes: 8 – 14m
FZLV SYSTEM CONFIGURATION HSP – fixture Helios IP65 2x3W, assembly altitudes: 2,5 – 8m
CODE POWER [W] SYSTEM COVER HWEM – fixture Helios IP42, assembly altitudes: 2,5 – 10 m
HWM HWEM 3,2 FZLV TR OP
HWED – fixture Helios IP42, assembly altitudes: 8 – 14m
HESP – fixture Helios IP42 2x3W, assembly altitudes: 2,5 – 8m
HWD HWED 3x1 FZLV TR
TR – transparent polycarbonate cover
HSP HESP 2x3 FZLV TR
OP – opal polycarbonate cover

22
Emergency escape lighting
HWM – LED 3,2W (257lm) for 2,5 to 10 m
HWM – min 0,5lx open area HWM – avg 1lx escape route
h [m] L1 L2 h [m] L1 L2
2,50 5,00 10,00 2,50 5,50 10,00
3,00 5,00 11,00 3,00 5,50 11,00
3,50 6,00 11,50 3,50 6,00 11,50
4,00 6,00 12,50 4,00 6,00 12,00
4,50 7,00 13,00 4,50 6,00 12,50
5,00 7,00 14,00 5,00 6,00 13,00
5,50 7,00 15,00 5,50 6,00 13,00
6,00 7,00 15,00 6,00 6,00 13,00
6,50 7,00 15,50 6,50 5,60 13,00
7,00 7,00 16,00 7,00 5,50 13,00
7,50 7,00 17,00 7,50 5,00 12,50
8,00 7,00 17,00 8,00 3,00 12,50
9,00 7,00 17,50 9,00 2,50 12,00
10,00 7,00 18,00 10,00 2,50 12,00

HWD – 3x1W (275lm) power LED for 8 to 14m


HWD – min 0,5lx open area HWD – avg 1lx escape route
h [m] L1 L2 h [m] L1 L2
8,00 5,00 9,00 8,00 5,00 9,00
8,50 5,00 9,00 8,50 5,50 10,00
9,00 5,00 9,00 9,00 6,00 10,00
9,50 6,00 9,50 9,50 6,00 10,00
10,00 6,00 10,00 10,00 6,00 10,50
10,50 6,00 10,50 10,50 6,00 11,00
11,00 6,00 10,50 11,00 6,00 11,00
11,50 7,00 11,00 11,50 6,00 11,50
12,00 7,00 11,00 12,00 6,00 12,00
13,00 7,00 12,00 13,00 6,00 12,00
14,00 7,00 12,00 14,00 6,00 11,00

HSP – 2x3W (436lm) power LED for 2,5 to 8m


HSP – avg 1lx,open area
h [m] L1 L2 L3 L4
2,50 2,00 5,00 8,00 18,00
3,00 3,00 6,00 8,00 18,00
3,50 3,00 7,00 8,00 18,00
4,00 3,00 7,00 8,00 18,00
4,50 3,00 8,00 8,00 18,00
5,00 3,00 7,00 8,00 18,00
6,00 3,00 7,00 8,00 18,00
7,00 3,00 7,00 8,00 18,00
8,00 3,00 5,00 8,00 18,00

Photometry

L1 L2 L3 L4

h h

L1 – distance from the wall to the first fixture L3 – distance from the wall to the first fixture
L2 – distance between fixtures L4 – distance between fixtures
h – height of the ceiling h – height of the ceiling

23
Emergency escape lighting
HELIOS

MATERIALS:
White polycarbonate body
Transparent polycarbonate cover with Fresnel optics
MOUNTING:
Surface (wall, ceiling)
Optional assembly with wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
8W, 11W, 18W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:

136
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP42 or IP65 356 79
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
230V
OPTIONS: 216V
AC T5 TC-SEL IP42 IP65
DC G5 2G7
SE – non maintained 50-60Hz
SA – maintained
PT – manual test button Ni-Cd
AT – autotest
RS – Rubic central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08

SELF CONTAINED CONFIGURATION Photometry


CODE POWER [W] AUTONOMY [h] MODE OPTION
HE 8 11 18 1 2 3 SE SA PT AT RS
Helios 8W

H 8 11 18* 1 2 3 SE SA PT AT RS
* AVAILABLE ONLY IN NON-MAINTAINED VERSION

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION
HE 8 11 18 CB CBS ADS ADL
H 8 11 18 CB CBS ADS ADL

Helios 11W Helios 18W

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
H – fixture Helios IP 65
HE – fixture Helios IP 42

24
Emergency escape lighting
EMX

MATERIALS:
White polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
2x8W, 18W, 24W, 36W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h, Ni-Cd batteries

160
INSULATION CLASS:
I
IP RATING:
IP65
400 100
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained 230V
216V
AC T5 TC-L IP65
SA – maintained DC G5
50-60Hz 2G11
PT – manual test button
AT – autotest
RS – RUBIC central monitoring Ni-Cd EVG
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION

EM 2x8 18 24 36 1 2 3 SE SA PT AT RS

CENTRAL BATTERY CONFIGURATION


Photometry
CODE POWER [W] SYSTEM OPTION

EM 2x8 18 24 36 CB CBS ADS ADL EM - 2x8W

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
EM – fixture EMX

25
Emergency escape lighting
TIGER LED

MATERIALS:
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optional assembly in dry-wall or under plastering
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE: 323
3,2W LED (270 lm)
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:

144
118
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP22 350
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
220-240V
OPTIONS: AC
216V 24V
LED IP22
DC DC
SE – non maintained 50-60Hz
SA – maintained
PT – manual test button
Ni-MH
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
Photometry
CB – central battery
ADDITIONAL INFORMATION: L1 L2
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C h
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR L1 – distance from the wall to the first fixture
TL 3,2 1 2 3 SE SA PT AT RS TR OP
L2 – distance between fixtures
h – height of the ceiling
TL – 3,2W (270lm)

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION COLOR

TL 3,2 CB CBS ADS ADL TR OP

FZLV SYSTEM CONFIGURATION


CODE POWER [W] SYSTEM COLOR
TL 3,2 FZLV TR OP

Legend:
TL 3,2W – avg 1lx escape route TL 3,2W – min 0,5lx open area
SE – non maintained transparent cover transparent cover
SA – maintained
h [m] L1 L2 h [m] L1 L2
PT – manual test button
AT – autotest 2,50 4,00 10,00 2,50 4,00 10,00

RS – Rubic central monitoring 3,00 4,00 10,50 3,00 4,50 11,00


FZLV – fixture for central battery FZLV 24 VDC 3,50 4,00 11,00 3,50 5,00 11,50
CB – central battery 4,00 4,00 11,00 4,00 5,00 12,50
CBS – central battery (circuit monitoring)
4,50 4,50 11,50 4,50 5,50 13,50
ADS – central battery with address module ADS 20
5,00 4,50 12,00 5,00 5,50 14,00
ADL – central battery with address module ADL
TL – fixture Tiger LED 6,00 4,50 13,00 6,00 6,00 15,00
TR – transparent polycarbonate cover 7,00 4,50 13,50 7,00 6,00 16,50
OP – opal polycarbonate cover 8,00 4,50 13,50 8,00 6,00 17,50

26
Emergency escape lighting
TIGER

MATERIALS:
White polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optional assembly in dry-wall or under plastering
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-Cd batteries 323
INSULATION CLASS:
II
IP RATING:
IP22

144
118
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 350
PT – manual test button
AT – autotest
RS – Rubic central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 230V
216V
Deep discharge protection AC T5 IP22
DC G5
50-60Hz
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
Ni-Cd

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION Photometry
TG 8 1 2 3 SE SA PT AT RS
TG – 8W

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION

TG 8 CB CBS ADS ADL

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TG – fixture Tiger

27
Emergency escape lighting
PANORAMA & PANORAMA LED

MATERIALS:
White plastic body
Opal plastic cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24 VDC
LIGHT SOURCE:
8W, 11W fluorescent lamp
3,2W LED
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h, Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP54
AMBIENT TEMPERATURE:

185
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest 330 45
RS – RUBIC central monitoring
FZLV – central battery FZLV
CB – central battery 220-240V
216V
216V 24V
24V
AC T5 TC-SEL
TC-SEL LED
ADDITIONAL INFORMATION: DC DC G5 2G7
2G 7
50-60Hzz
50-60H
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version Ni-Cd
Ni-Cd EVG
EVG

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION
P 8 11 1 2 3 SE SA PT AT RS
PML 3,2 1 2 3 SE SA PT AT RS

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION

P 8 11 CB CBS ADS ADL

PML 3,2 CB CBS ADS ADL

FZLV SYSTEM CONFIGURATION


CODE POWER [W] SYSTEM
PML 3,2 FZLV

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
FZLV – central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
P – fixture Panorama
PML – fixture Panorama LED

28
Emergency escape lighting
OUTDOOR LED

MATERIALS:
Stainless steel painted white
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24 VDC
LIGHT SOURCE:
3x1W (256lm) power LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY & BATTERIES:
1h, 2h, or 3h, Ni-MH batteries
INSULATION CLASS:
I
IP RATING:
IP 65 222
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained

227
SA – maintained
AT – autotest
RS – RUBIC central monitoring

77
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 220-240V
216V
216V 24V
24V
Deep discharge protection AC
DC DC
LED IP65
50-60Hzz
50-60H
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION


Ni-MH
CODE POWER [W] AUTONOMY [h] MODE OPTION
ODB 3x1 1 2 3 SE SA PT AT RS

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION
ODB 3x1 CB CBS ADS ADL

FZLV SYSTEM CONFIGURATION


R1 – radius of the illumination for avg. 5lx
CODE POWER [W] SYSTEM R1’ – distance from the wall for avg. 5lx
ODB 3x1 FZLV h R2 – radius of the illumination for avg. 1lx
R'2
R2 R2’ – distance from the wall for avg. 1lx
Legend: R1 R'1 h – assembly height of the fitting
p1
SE – non maintained p1 – max light intensity under the luminaire
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL ODB 3x1W (256lm)
ODB – fixture Outdoor LED
Photometry
h [m] - assembly p1 [lx] - R1 [m] R1’ [m] R2 [m] R2’ [m]
height of the max under for avg. for avg. for avg. for avg.
fitting the fitting 5lx 5lx 1lx 1lx

2 22 3,7 2,6 6,2 4,9


2,2 18 3,7 2,6 6,4 5
2,4 15 3,6 2,6 6,6 5,1
2,6 12 3,5 2,6 6,9 5,2
2,8 11 3,4 2,5 7,2 5,4
3 9,3 3,2 2,4 7,4 5,5
3,2 8,1 2,9 2,3 7,7 5,8
3,4 7,1 2,5 2,1 7,9 5,7
3,6 6,3 2,1 1,9 8,1 5,7

29
Emergency escape lighting
SQUARE

MATERIALS:
White plastic body
Opal plastic cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
1x 11W, 18W fluorescent lamp
2x 11W, 18W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h, Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP54
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained

360
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 360 83
Deep discharge protection

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION 230V
216V
AC TC-SEL TC-L IP54
DC 2G7
SD 11 2x11 18 2x18* 1 2 3 SE SA PT AT RS 50-60Hz 2G11

* Available only in non-maintained version


Ni-Cd EVG

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION
Photometry
SD 11 2x11 18 2x18 CB CBS ADS ADL

SD – 18W

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
SD – fixture Square

30
Emergency escape lighting
Twister

MATERIALS:
White plastic body
Opal plastic cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
1x 11W, 18W fluorescent lamp
2x 11W, 18W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h, Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP54
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained

360
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 360 83
Deepdischargeprotection

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION 230V
216V
AC TC-SEL TC-L IP54
DC 2G7
TD 11 2x11 18 2x18* 1 2 3 SE SA PT AT RS 50-60Hz 2G11

* Available only in non-maintained version


Ni-Cd EVG

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION
Photometry
TD 11 2x11 18 2x18 CB CBS ADS ADL

TD – 18W

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TD – fixture Twister

31
Emergency escape lighting
HERMETICA

MATERIALS:
Grey polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (ceiling)
POWER SUPPLY: A
Self contained – 220÷240VAC/50÷60Hz D
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
1x 14, 18, 24, 28, 35, 36, 49, 54, 58, 80W fluorescent lamp
2x 14, 18, 24, 28, 35, 36, 49, 54, 58, 80W fluorescent lamp
CHARGING:

113
100
Maximum 12h
AUTHONOMY AND BATTERIES:
1h, 2h or 3h, Ni-Cd batteries 140 90
INSULATION CLASS:
I
IP RATING:
220-240V
IP65 216V
AC IP65 T8 T5
DC G13 G5
AMBIENT TEMPERATURE: 50-60Hz
ta: 0°C÷40°C
OPTIONS: Ni-Cd EVG
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery Dimensions [mm]

ADDITIONAL INFORMATION: POWER [W] AxD


LED indicator signalizes mains power supply and battery charge 1x14/18/24 670x350
Deep discharge protection
2x14/18/24 670x350
Optional adaptation of the fixture for low temperatures up to –25 °C
1x28/36/54 1270x700
Protection against mechanical impacts – IK08
2x28/36/54 1270x700
1x35/49/58/80 1570x940
2x35/49/58/80 1570x940

Photometry
SELF CONTAINED CONFIGURATION
HR – 1x18W HR – 2x18W
CODE POWER [W] AUTONOMY [h] mode OPTION

HR 14 2x14 1 2 3 SE SA PT AT RS
HR 18 2x18 1 2 3 SE SA PT AT RS
HR 24 2x24 1 2 3 SE SA PT AT RS
HR 28 2x28 1 2 3 SE SA PT AT RS
HR 35 2x35 1 2 3 SE SA PT AT RS
HR 36 2x36 1 2 3 SE SA PT AT RS
HR 49 2x49 1 2 3 SE SA PT AT RS
HR 54 2x54 1 2 3 SE SA PT AT RS
HR 58 2x58 1 2 3 SE SA PT AT RS
HR 80 2x80 1 2 3 SE SA PT AT RS

CENTRAL BATTERY CONFIGURATION

CODE POWER [W] SYSTEM OPTION

HR 14 2x14 CB CBS ADS ADL


Legend:
HR 18 2x18 CB CBS ADS ADL SE – non maintained
HR 24 2x24 CB CBS ADS ADL SA – maintained
HR 28 2x28 CB CBS ADS ADL PT – manual test button
HR 35 2x35 CB CBS ADS ADL AT – autotest
RS – RUBIC central monitoring
HR 36 2x36 CB CBS ADS ADL
CB – central battery
HR 49 2x49 CB CBS ADS ADL
CBS – central battery (circuit monitoring)
HR 54 2x54 CB CBS ADS ADL ADS – fixture to the central battery with address module ADS 20
HR 58 2x58 CB CBS ADS ADL ADL – fixture to the central battery with address module ADL
HR 80 2x80 CB CBS ADS ADL HR – fixture Hermetica

32
Emergency escape lighting
JOBLED

MATERIALS:
Black, hit resistant polycarbonate
POWER SUPPLY:
230 VAC/50Hz optionally – 12 VDC
LIGHT SOURCE:
3W (120 lm) highpower LED
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
8,5h 6V / 4,0 Ah batteries
INSULATION CLASS:
II
IP RATING:
IP43
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Charging through wall mounted adapter or directly from mains 230V

132
SELF CONTAINED CONFIGURATION 128
CODE POWER [W] AUTONOMY [h]

JOBLED 3 8,5 290

130
112
80 55 Ø130

230V
AC IP43
DC
50-60Hz

33
emergency exit signS

SK-836
INFINITY B 37
INFINITY AC & INFINITY AS 38
INFINITY AD & INFINITY AR 39
TWINS40
PLEXI LED 41
ESCAPE & ESCAPE LED 42
HELIOS & HELIOS LED 43
HELIOS DS & HELIOS DS LED 44
HELIOS P & HELIOS P LED 45
TIGER & TIGER LED 46
TIGER DS & TIGER DS LED 47
TIGER P & TIGER P LED 48
PANORAMA & PANORAMA LED 49
SCREEN50
SCREEN DS 51
EMX52
QUADRO53

SK-8 INFINITY B INFINITY AC & INFINITY AD TWINS PLEXI LED ESCAPE


INFINITY AS & INFINITY AR & ESCAPE LED

HELIOS HELIOS DS HELIOS P TIGER TIGER DS TIGER P PANORAMA


& HELIOS LED & HELIOS DS LED & HELIOS P LED & TIGER LED & TIGER DS LED & TIGER P LED & PANORAMA
LED

SCREEN SCREEN DS EMX QUADRO


Two-sided emergency exit signs
SK-8

MATERIALS:
White polycarbonate body
Opal or transparent polycarbonate cover
MOUNTING:
Surface (ceiling, wall)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W or 3,2W LED
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
II
IP RATING: 310
IP44
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C

250
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest 20
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery 220-240V
216V 24V
AC LED IP44
ADDITIONAL INFORMATION: DC DC
50-60Hz
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Ni-Cd
III class of insulation of FZLV version
d=30m

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR/COVER
SK8 1,2 3,2 1 2 3 SE SA PT AT RS WT WL GT GL

CENTRAL BATTERY CONFIGURATION


*see pictogram
CODE POWER [W] SYSTEM OPTION COLOR/COVER
SK8 1,2 3,2 CB CBS ADS ADL WT WL GT GL

FZLV SYSTEM CONFIGURATION


CODE POWER [W] SYSTEM COLOR/COVER
SK8 1,2 3,2 FZLV WT WL GT GL

Legend:
SE – non maintained
SA – maintained
PT - manual test button
AT - autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
SK8 - fixture SK-8
WT - white body and transparent cover
WL - white body and opal cover
GT - grey body and transparent cover
GL - grey body and opal cover

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

36
ONE-sided emergency exit signs
INFINITY B

MATERIALS:
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Recessed (wall)
Surface (wall)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II 28 43
IP RATING:
IP44
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:

180
123
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 330
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 220-240V
216V 24V
AC LED IP44
CB – central battery DC DC
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Ni-MH
Deep discharge protection
d=30m
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
IFB 3,2 1 2 3 SE SA PT AT RS WH GR BL

CENTRAL BATTERY CONFIGURATION


*see pictogram
CODE POWER [W] SYSTEM OPTION COLOR

IFB 3,2 CB CBS ADS ADL WH GR BL

FZLV SYSTEM CONFIGURATION


CODE POWER [W] SYSTEM COLOR
IFB 3,2 FZLV WH GR BL

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
IFB – fixture Infinity B
WH – fixture in white color
GR – fixture in grey color
BL – fixture in black color

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

37
Two-sided emergency exit signs
INFINITY AC & INFINITY AS

MATERIALS:
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Surface (ceiling, rope sling)
Optional wall assembly using the bracket
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP44
VIEWING DISTANCE: 330 45
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C

70
OPTIONS:
SE – non maintained

250
SA – maintained

180
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V infinity ac 15
CB – central battery
ADDITIONAL INFORMATION: 330
LED indicator mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version

70
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
max 1m

IFAC 3,2 1 2 3 SE SA PT AT RS WH GR BL

180
IFAS 3,2 1 2 3 SE SA PT AT RS WH GR BL

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION COLOR infinity as 15
IFAC 3,2 CB CBS ADS ADL WH GR BL

IFAS 3,2 CB CBS ADS ADL WH GR BL

220-240V
FZLV SYSTEM CONFIGURATION 216V 24V
AC LED IP44
DC DC
CODE POWER [W] SYSTEM COLOR 50-60Hz

IFAC 3,2 FZLV WH GR BL


IFAS 3,2 FZLV WH GR BL Ni-MH
d=30m
Legend:
SE – non maintained ADL – central battery with
SA – maintained address module ADL
PT – manual test button IFAC – fixture Infinity AC
AT – autotest IFAS – fixture Infinity AS
RS – Rubic central monitoring WH – fixture in white color
FZLV – fixture for central battery GR – fixture in grey color
FZLV 24 VDC BL – fixture in black color *see pictogram
CB – central battery
CBS – central battery (circuit
monitoring)
ADS – central battery with
address module ADS 20

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

38
ssTwo-sided emergency exit signs

INFINITY AD & INFINITY AR

MATERIALS:
Steel body in gray, black or white color
Plexi glass in grey, black or white polycarbonate frame
MOUNTING:
Recessed (ceiling, rope sling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP44
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
IFAD 3,2 1 2 3 SE SA PT AT RS WH GR BL
IFAR 3,2 1 2 3 SE SA PT AT RS WH GR BL

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION COLOR

IFAD 3,2 CB CBS ADS ADL WH GR BL

IFAR 3,2 CB CBS ADS ADL WH GR BL

FZLV SYSTEM CONFIGURATION 220-240V


216V 24V
AC LED IP44
CODE POWER [W] SYSTEM COLOR DC DC
50-60Hz
IFAD 3,2 FZLV WH GR BL
IFAR 3,2 FZLV WH GR BL
Ni-MH
d=30m
Legend:
SE – non maintained ADL – central battery with
SA – maintained address module ADL
PT – manual test button IFAD – fixture Infinity AD
AT – autotest IFAR – fixture infinity AR
RS – Rubic central monitoring WH – fixture in white color
FZLV – fixture for central battery GR – fixture in grey color
FZLV 24 VDC BL – fixture in black color *see pictogram
CB – central battery
CBS – central battery (circuit
monitoring)
ADS – central battery with
address module ADS 20

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

39
Two-sided emergency exit signs
TWINS

MATERIALS:
Silver or black aluminium body
Plexi glass
MOUNTING:
Surface (ceiling, wall)
Assembly on rope slings or wall mounting bracket as an option
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
I
IP RATING: 315 48
IP41
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:

83
ta: 0°C÷40°C
OPTIONS:

243
SE – non maintained
SA – maintained

160
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: 230V
216V 24V
AC LED T5 IP41
LED indicator signalizes mains power supply and battery charge DC DC G5
50-60Hz
Deep discharge protection
III class of insulation of FZLV version
Ni-Cd
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION
TW 1,2 8 1 2 3 SE SA PT AT RS EVG
TWB 1,2 8 1 2 3 SE SA PT AT RS d=30m

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION

TW 1,2 8 CB CBS ADS ADL

TWB 1,2 8 CB CBS ADS ADL

FZLV SYSTEM CONFIGURATION *see pictogram


CODE POWER [W] SYSTEM
TW 1,2 FZLV
TWB 1,2 FZLV

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TW – fixture Twins
TWB – fixture Twins black

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

40
ssTwo-sided emergency exit signs

PLEXI LED

MATERIALS:
Steel body in grey or white color
Plexi glass
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP20 325 45
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:

210
170
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 355 110
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 230V
216V 24V
AC LED T5 IP20
Deep discharge protection DC DC G5
50-60Hz
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION Ni-Cd EVG


CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
PL 1,2 1 2 3 SE SA PT AT RS GR WH
PL 8 1 2 3 SE SA PT AT RS GR WH
d=30m
CENTRAL BATTERY CONFIGURATION
CODE POWER [W] SYSTEM OPTION COLOR

PL 1,2 CB CBS ADS ADL GR WH

PL 8 CB CBS ADS ADL GR WH

FZLV SYSTEM CONFIGURATION


*see pictogram
CODE POWER [W] SYSTEM
PL 1,2 FZLV
Dimensions of assembly hole [a x b x h ] 65 x 330 x 110mm

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
PL – fixture Plexi led
GR – fixture in grey color
Wh – fixture in white color

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

41
Two-sided emergency exit signs
ESCAPE & ESCAPE LED

MATERIALS:
Steel body in white color
Plexi glass
MOUNTING:
Surface (ceiling)
Optional wall assembly using the bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
I 352 60
IP RATING:
IP20
VIEWING DISTANCE:

69
30m
AMBIENT TEMPERATURE:

228
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 230V
216V 24V
AC LED T5 IP20
FZLV – central battery FZLV 24V DC DC G5
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
Ni-Cd
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
EVG
SELF CONTAINED CONFIGURATION
d=30m
CODE POWER [W] AUTONOMY [h] MODE OPTION
E 8 1 2 3 SE SA PT AT RS
EL 1,2 1 2 3 SE SA PT AT RS

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION

E 8 CB CBS ADS ADL


*see pictogram
EL 1,2 CB CBS ADS ADL

FZLV SYSTEM CONFIGURATION


CODE POWER [W] SYSTEM
EL 1,2 FZLV

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
E – fixture Escape
EL – fixture Escape LED

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

42
ONE-sided emergency exit signs
HELIOS & HELIOS LED

MATERIALS:
White polycarbonate body
Transparent cover with Fresnel optics or opal polycarbonate cover
MOUNTING:
Surface (wall)
Optional assembly with wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
II

136
IP RATING:
IP42 or IP65
VIEWING DISTANCE:
25m
356 79
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 230V
216V 24V
AC LED T5 IP42 IP65
FZLV – central battery FZLV 24V DC DC G5
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
Ni-Cd
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COVER
H 8 1 2 3 SE SA PT AT RS TF
HE 8 1 2 3 SE SA PT AT RS TF

HL 1,2 1 2 3 SE SA PT AT RS OP
*see pictogram
HEL 1,2 1 2 3 SE SA PT AT RS OP

CENTRAL BATTERY CONFIGURATION Legend:


CODE POWER [W] SYSTEM OPTION COVER SE – non maintained
SA – maintained
H 8 CB CBS ADS ADL TF
PT – manual test button
HE 8 CB CBS ADS ADL TF AT – autotest
HL 1,2 CB CBS ADS ADL OP RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
HEL 1,2 CB CBS ADS ADL OP
CB – central battery
CBS – central battery (circuit monitoring)
FZLV SYSTEM CONFIGURATION ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
CODE POWER [W] SYSTEM COVER
HE – fixture Helios IP42
HL 1,2 FZLV OP
H – fixture Helios IP65
HEL 1,2 FZLV OP HEL – fixture Helios led IP42
HL – fixture Helios led IP65
TF – transparent cover with Fresnel optics
OP – opal polycarbonate cover

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

43
Two-sided emergency exit signs
HELIOS DS & HELIOS DS LED

MATERIALS:
White polycarbonate body
Opal polycarbonate cover
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS: 356 136
II
IP RATING:
IP42 or IP65
VIEWING DISTANCE:
25m

219
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 33
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 230V
216V 24V
AC LED T5 IP42
CB – central battery DC DC G5
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Ni-Cd
Deep discharge protection IP65
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08
III class of insulation of FZLV version EVG
d=25m

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION
HD 8 1 2 3 SE SA PT AT RS
HDE 8 1 2 3 SE SA PT AT RS

HDL 1,2 1 2 3 SE SA PT AT RS
*see pictogram
HDEL 1,2 1 2 3 SE SA PT AT RS

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION
Legend:
HD 8 CB CBS ADS ADL
SE – non maintained
HDE 8 CB CBS ADS ADL SA – maintained
HDL 1,2 CB CBS ADS ADL PT – manual test button
AT – autotest
HDEL 1,2 CB CBS ADS ADL
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
FZLV SYSTEM CONFIGURATION CBS – central battery (circuit monitoring)
CODE POWER [W] SYSTEM ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
HDL 1,2 FZLV
HDE – fixture Helios DS IP42
HDEL 1,2 FZLV
HD – fixture Helios DS IP65
HDEL – fixture Helios DS LED IP42
HDL – fixture Helios DS LED IP65

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

44
ssTwo-sided emergency exit signs

HELIOS P & HELIOS P LED

MATERIALS:
White polycarbonate body
Transparent cover with Fresnel optics
Plexi glass
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS: 356 136
II
IP RATING:
IP42
VIEWING DISTANCE:
30m

225
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 230V
216V 24V
AC LED T5 IP42
FZLV – central battery FZLV 24V DC DC G5
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
Ni-Cd EVG
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – Ik07
III class of insulation of FZLV version d=30m

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION
HP 8 1 2 3 SE SA PT AT RS
HPL 1,2 1 2 3 SE SA PT AT RS

*see pictogram

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION

HP 8 CB CBS ADS ADL

HPL 1,2 CB CBS ADS ADL

Legend:
FZLV SYSTEM CONFIGURATION SE – non maintained
CODE POWER [W] SYSTEM SA – maintained
PT – manual test button
HPL 1,2 FZLV
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
HP – fixture Helios P
HPL – fixture Helios P LED

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

45
ONE-sided emergency exit signs

TIGER & TIGER LED

MATERIALS:
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall)
Optional assembly in dry-wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES: 323
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:

144
118
IP22
VIEWING DISTANCE:
20m
AMBIENT TEMPERATURE:
350
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest 230V
216V 24V
AC LED T5 IP22
RS – Rubic central monitoring DC DC G5
50-60Hz
FZLV – central battery FZLV 24V
CB – central battery
Ni-Cd EVG
ADDITIONAL INFORMATION:
d=20m
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION COVER
TG 8 1 2 3 SE SA PT AT RS TR
TL 1,2 1 2 3 SE SA PT AT RS OP

*see pictogram

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION COVER

TG 8 CB CBS ADS ADL TR

TL 1,2 CB CBS ADS ADL OP


Legend:
SE – non maintained
SA – maintained
PT – manual test button
FZLV SYSTEM CONFIGURATION
AT – autotest
CODE POWER [W] SYSTEM COVER
RS – Rubic central monitoring
TL 1,2 FZLV TR OP FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TG – fixture Tiger
TL – fixture Tiger LED
TR – transparent polycarbonate cover
OP – opal polycarbonate cover

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

46
ssTwo-sided emergency exit signs

TIGER DS & TIGER DS LED

MATERIALS:
White polycarbonate body
Opal polycarbonate cover
MOUNTING:
Surface (ceiling)
Optional assembly in dry-wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
323 118
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP22
VIEWING DISTANCE:

186
20m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
350 144
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 230V
216V 24V
AC LED T5 IP22
FZLV – central battery FZLV 24V DC DC G5
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
Ni-Cd
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
EVG
d=20m

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION
TGS 8 1 2 3 SE SA PT AT RS
TSL 1,2 1 2 3 SE SA PT AT RS

*see pictogram

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION

TGS 8 CB CBS ADS ADL

TSL 1,2 CB CBS ADS ADL

Legend:
SE – non maintained
FZLV SYSTEM CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM
PT – manual test button
TSL 1,2 FZLV AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TGS – fixture Tiger DS
TSL – fixture Tiger DS LED

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

47
Two-sided emergency exit signs
TIGER P & TIGER P LED

MATERIALS:
White polycarbonate body
Transparent polycarbonate cover
Plexi glass
MOUNTING:
Surface (ceiling)
Optional assembly in dry-wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
8W fluorescent lamp
1,2W LED
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES: 323 118
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP22

192
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS: 350 144
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest 230V
216V 24V
AC LED T5 IP22
RS – Rubic central monitoring DC DC G5
50-60Hz
FZLV – central battery FZLV 24V
CB – central battery
Ni-Cd
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version EVG
d=30m

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION
TP 8 1 2 3 SE SA PT AT RS
TPL 1,2 1 2 3 SE SA PT AT RS

*see pictogram

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION

TP 8 CB CBS ADS ADL

TPL 1,2 CB CBS ADS ADL

Legend:
SE – non maintained
FZLV SYSTEM CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM
PT – manual test button
TPL 1,2 FZLV AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TP – fixture Tiger P
TPL – fixture Tiger P LED

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

48
ONE-sided emergency exit signs
PANORAMA & PANORAMA LED

MATERIALS:
White plastic body
Opal plastic cover
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery–220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
8W fluorescent lamp
1,2W LED
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP54
VIEWING DISTANCE:

185
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 330 45
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 230V
216V 24V
AC LED T5 TC-SEL IP54
CB – central battery DC DC G5 2G7
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Ni-Cd EVG
Deep discharge protection
d=30m
III class of insulation of FZLV version

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION
P 8 1 2 3 SE SA PT AT RS
PML 1,2 1 2 3 SE SA PT AT RS

*see pictogram

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION

P 8 CB CBS ADS

PML 1,2 CB CBS ADS

Legend:
SE – non maintained
FZLV SYSTEM CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM
PT – manual test button
PML 1,2 FZLV AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
P – fixture Panorama
PML – fixture Panorama LED

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

49
ONE-sided emergency exit signs
SCREEN

MATERIALS:
Aluminium body
Plexi glass
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 220-240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
SC30 3x1W; SC40 3,2W; SC60 2x3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
I
IP RATING:
IP40
VIEWING DISTANCE:

b
30, 40 or 60m (depends on version)
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained a c d
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 220-240V
216V 24V
AC LED IP40
FZLV – central battery FZLV 24V DC DC
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge Ni-MH
d=30m d=40m d=60m
Deep discharge protection
III class of insulation of FZLV version

*see pictogram

SELF CONTAINED CONFIGURATION Dimensions [mm]


CODE POWER [W] AUTONOMY [h] MODE OPTION TYPE a[mm] b[mm] c[mm] d[mm]
SC30 3x1 1 2 3 SE SA PT AT RS SCS30 315 165 50 8
SC40 3,2 1 2 3 SE SA PT AT RS SCS40 415 215 50 8

SC60 2x3,2 1 2 3 SE SA PT AT RS SCS60 615 315 50 8

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION

SC30 3x1 CB CBS ADS ADL


Legend:
SE – non maintained
SC40 3,2 CB CBS ADS ADL SA – maintained
SC60 2x3,2 CB CBS ADS ADL PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
FZLV SYSTEM CONFIGURATION CB – central battery
CODE POWER [W] SYSTEM CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
SC30 3x1 FZLV
ADL – central battery with address module ADL
SC40 3,2 FZLV
SC30 – fixture Screen viewing distance 30m
SC60 2x3,2 FZLV SC40 – fixture Screen viewing distance 40m
SC60 – fixture Screen viewing distance 60m

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

50
ssTwo-sided emergency exit signs

SCREEN DS

MATERIALS:
Aluminium body
Plexi glass
MOUNTING:
Surface (ceiling) or mounting on a rope sling
POWER SUPPLY:
Self contained – 220-240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
SCS30 3x1W; SCS40 3,2W; SCS60 2x3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
I
IP RATING:
IP40
VIEWING DISTANCE:

b
30, 40 or 60m (depends on version)
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained a c
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 220-240V
216V 24V
AC LED IP40
FZLV – central battery FZLV 24V DC DC
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge Ni-MH
d=30m d=40m d=60m
Deep discharge protection
III class of insulation of FZLV version

*see pictogram

SELF CONTAINED CONFIGURATION Dimensions [mm]


CODE POWER [W] AUTONOMY [h] MODE OPTION TYPE a[mm] b[mm] c[mm]
SCS30 3x1 1 2 3 SE SA PT AT RS SC30 315 165 50
SCS40 3,2 1 2 3 SE SA PT AT RS SC40 415 215 50

SCS60 2x3,2 1 2 3 SE SA PT AT RS SC60 615 315 50

CENTRAL BATTERY CONFIGURATION


CODE POWER [W] SYSTEM OPTION Legend:
SCS30 3x1 CB CBS ADS ADL
SE – non maintained
SA – maintained
SCS40 3,2 CB CBS ADS ADL PT – manual test button
SCS60 2x3,2 CB CBS ADS ADL AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
FZLV SYSTEM CONFIGURATION CBS – central battery (circuit monitoring)
CODE POWER [W] SYSTEM ADS – central battery with address module ADS 20
SCS30 3x1 FZLV
ADL – central battery with address module ADL
SCS30 – fixture Screen DS viewing distance 30m
SCS40 3,2 FZLV
SCS40 – fixture Screen DS viewing distance 40m
SCS60 2x3,2 FZLV
SCS60 – fixture Screen DS viewing distance 60m

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

51
ONE-sided emergency exit signs
EMX

MATERIALS:
White polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
2x8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP65
VIEWING DISTANCE:
25m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C

160
OPTIONS: 
SE – non maintained
SA – maintained
PT – manual test button
400 100
AT – autotest
RS – Rubic central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C

230V
216V
AC T5 IP65
DC G5
50-60Hz

Ni-Cd EVG
d=25m

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION
EM 2x8 1 2 3 SE SA PT AT RS

*see pictogram
CENTRAL BATTERY CONFIGURATION
CODE POWER [W] SYSTEM OPTION

EM 2x8 CB CBS ADS ADL

Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
EM – fixture EMX

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

52
Four-sided emergency exit signs
QUADRO

MATERIALS:
Opal plexi glass body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3x1W LED
11W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP41
VIEWING DISTANCE:
25m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained

240
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: 240
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version

230V
24V
AC TC-SEL LED
DC 2G7
50-60Hz

Ni-Cd EVG
d=25m

SELF CONTAINED CONFIGURATION


CODE POWER [W] AUTONOMY [h] MODE OPTION
Q 11 3x1 1 2 3 SE SA PT AT RS

*see pictogram
CENTRAL BATTERY CONFIGURATION
CODE POWER [W] SYSTEM OPTION

Q 11 3x1 CB CBS ADS ADL

Legend:
FZLV SYSTEM CONFIGURATION SE – non maintained
CODE POWER [W] SYSTEM SA – maintained
PT – manual test button
Q 3x1 FZLV
AT – autotest
RS – Rubic central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
Q – fixture Quadro

*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.

53
emergency conversion kits

NEXT & NEXT AUTOTEST 56


NEXT PLUS & NEXT PLUS AUTOTEST 57
LIDER EVG 58
LIDER PLUS & LIDER PLUS AUTOTEST 59
LIN60
LINEX & LINEX AUTOTEST 61
UNILED BM 62
UNILED GU10 63
UNILED UM 64

NEXT & NEXT NEXT PLUS LIDER EVG LIDER PLUS LIN LINEX & LINEX UNILED BM
AUTOTEST & NEXT PLUS & LIDER PLUS AUTOTEST
AUTOTEST AUTOTEST

UNILED GU10 UNILED UM


emergency conversion kits
NEXT & NEXT AUTOTEST

MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
230 VAC/50-60 Hz
LIGHT SOURCE:
Linear and compact fluorescent lamps
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-Cd battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷55°C

35
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:

42
A new generation of conversion kits which replaces conversion kits series LIDER
LED indicator signalizes mains power supply and battery charge
Deep discharge protection 157
Cooperation with magnetic and electronic ballasts
Optional adaptation of conversion kit for low temperatures up to -25°C
230V
Ni-Cd
AC IP20
50-60Hz

NEXT - ORDER CODES


CODE POWER [W] AUTONOMY [h] OPTION BATTERY
NX/36/1 6 – 36 1 PT Ni-Cd 3,6V 1,5Ah
NX/36/2 6 – 36 2 PT Ni-Cd 3,6V 2,5Ah
NX/36/3 6 – 36 3 PT Ni-Cd 3,6V 4,0Ah
NX/58/1 6 – 58 1 PT Ni-Cd 4,8V 1,5Ah
NX/58/2 6 – 58 2 PT Ni-Cd 4,8V 2,5Ah
NX/58/3 6 – 58 3 PT Ni-Cd 4,8V 4,0Ah
NX/80/1 6 – 80 1 PT Ni-Cd 6,0V 1,5Ah
NX/80/2 6 – 80 2 PT Ni-Cd 6,0V 2,5Ah
NX/80/3 6 – 80 3 PT Ni-Cd 6,0V 4,0Ah

NEXT AUTOTEST - ORDER CODES


CODE POWER [W] AUTONOMY [h] BATTERY
NX/36/1/AT 6 – 36 1 Ni-Cd 3,6V 2,0Ah
NX/36/3/AT 6 – 36 3 Ni-Cd 3,6V 4,5Ah
NX/58/1/AT 6 – 58 1 Ni-Cd 4,8V 2,0Ah
NX/58/3/AT 6 – 58 3 Ni-Cd 4,8V 4,5Ah
NX/80/1/AT 6 – 80 1 Ni-Cd 6,0V 2,0Ah
NX/80/3/AT 6 – 80 3 Ni-Cd 6,0V 4,5Ah

Test types (version AT):

Test A is run automatically every 28 days


During test A a conversion kit is switched to emergency mode
LED indicator
for 1 minute and the following parameters are checked:
LED color Signal Symbolizing • control of battery power discharge
no signal emergency mode / running test • control of battery voltage
shining defective battery
Test B is run automatically every 364 days
flashing defective lamp
During test B a conversion kit is switched to emergency
no signal emergency mode / running test mode for all duration time (1, 2, 3 hours) and the following
shining normal mode parameters are checked:
• control of battery power discharge
flashing normal mode, battery charging
• control of minimum battery voltage

56
emergency conversion kits
NEXT PLUS & NEXT PLUS AUTOTEST

MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz
LIGHT SOURCE:
Linear and compact fluorescent lamps
CHARGING:
Maximum 12h; electronic energy-saving impulse charger
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-Cd or Ni-MH battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:

35
ta: 0°C÷55°C
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:

42
A new generation of conversion kits which replaces conversion kits series LIDER
LED indicator signalizes mains power supply and battery charge
Deep discharge protection 157
Cooperation with magnetic and electronic ballasts
Optional adaptation of conversion kit for low temperatures up to -25°C
220-240V
Ni-Cd Ni-MH
AC IP20
50-60Hz

NEXT PLUS - ORDER CODES NEXT PLUS NIMH - ORDER CODES


CODE POWER [W] AUTONOMY [h] OPTION BATTERY CODE POWER [W] AUTONOMY [h] OPTION BATTERY
NXP/36/1 6 – 36 1 PT Ni-Cd 3,6V 1,5Ah NXH/36/1 6 – 36 1 PT Ni-MH 3,6V 1,5Ah
NXP/36/2 6 – 36 2 PT Ni-Cd 3,6V 2,5Ah NXH/36/2 6 – 36 2 PT Ni-MH 3,6V 2,5Ah
NXP/36/3 6 – 36 3 PT Ni-Cd 3,6V 4,0Ah NXH/36/3 6 – 36 3 PT Ni-MH 3,6V 4,0Ah
NXP/58/1 6 – 58 1 PT Ni-Cd 4,8V 1,5Ah NXH/58/1 6 – 58 1 PT Ni-MH 4,8V 1,5Ah
NXP/58/2 6 – 58 2 PT Ni-Cd 4,8V 2,5Ah NXH/58/2 6 – 58 2 PT Ni-MH 4,8V 2,5Ah
NXP/58/3 6 – 58 3 PT Ni-Cd 4,8V 4,0Ah NXH/58/3 6 – 58 3 PT Ni-MH 4,8V 4,0Ah
NXP/80/1 6 – 80 1 PT Ni-Cd 6,0V 1,5Ah NXH/80/1 6 – 80 1 PT Ni-MH 6,0V 1,5Ah
NXP/80/2 6 – 80 2 PT Ni-Cd 6,0V 2,5Ah NXH/80/2 6 – 80 2 PT Ni-MH 6,0V 2,5Ah
NXP/80/3 6 – 80 3 PT Ni-Cd 6,0V 4,0Ah NXH/80/3 6 – 80 3 PT Ni-MH 6,0V 4,0Ah

NEXT PLUS AUTOTEST - ORDER CODES


NEXT PLUS AUTOTEST NIMH - ORDER CODES
CODE POWER [W] AUTONOMY [h] BATTERY
CODE POWER [W] AUTONOMY [h] BATTERY
NXP/36/1/AT 6 – 36 1 Ni-Cd 3,6V 2,0Ah
NXH/36/1/AT 6 – 36 1 Ni-MH 3,6V 2,0Ah
NXP/36/3/AT 6 – 36 3 Ni-Cd 3,6V 4,5Ah
NXH/36/3/AT 6 – 36 3 Ni-MH 3,6V 4,5Ah
NXP/58/1/AT 6 – 58 1 Ni-Cd 4,8V 2,0Ah
NXH/58/1/AT 6 – 58 1 Ni-MH 4,8V 2,0Ah
NXP/58/3/AT 6 – 58 3 Ni-Cd 4,8V 4,5Ah
NXH/58/3/AT 6 – 58 3 Ni-MH 4,8V 4,5Ah
NXP/80/1/AT 6 – 80 1 Ni-Cd 6,0V 2,0Ah
NXH/80/1/AT 6 – 80 1 Ni-MH 6,0V 2,0Ah
NXP/80/3/AT 6 – 80 3 Ni-Cd 6,0V 4,5Ah
NXH/80/3/AT 6 – 80 3 Ni-MH 6,0V 4,5Ah

Test types (version AT):

Test A is run automatically every 28 days


LED indicator
During test A a conversion kit is switched to emergency mode for
LED color Signal Symbolizing 1 minute and the following parameters are checked:
no signal emergency mode / running test • control of battery power discharge
shining defective battery
• control of battery voltage

flashing defective lamp


Test B is run automatically every 364 days
no signal emergency mode / running test During test B a conversion kit is switched to emergency mode for all
shining normal mode duration time (1, 2, 3 hours) and the following parameters are checked:
• control of battery power discharge
flashing normal mode, battery charging
• control of minimum battery voltage

57
emergency conversion kits
LIDER EVG

MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
230 VAC/50-60 Hz
LIGHT SOURCE:
Linear and compact fluorescent lamps
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-Cd battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷55°C

35
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:

42
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Cooperation with magnetic and electronic ballasts
157
Optional adaptation of conversion kit for low temperatures up to -25°C

230V
Ni-Cd
AC IP20
50-60Hz

LIDER EVG - ORDER CODES


CODE POWER [W] AUTONOMY [h] OPTION BATTERY
LE/36/1 6 – 36 1 PT Ni-Cd 3,6V 1,5Ah
LE/36/2 6 – 36 2 PT Ni-Cd 3,6V 2,5Ah
LE/36/3 6 – 36 3 PT Ni-Cd 3,6V 4,0Ah
LE/58/1 6 – 58 1 PT Ni-Cd 4,8V 1,5Ah
LE/58/2 6 – 58 2 PT Ni-Cd 4,8V 2,5Ah
LE/58/3 6 – 58 3 PT Ni-Cd 4,8V 4,0Ah
LE/80/1 6 – 80 1 PT Ni-Cd 6,0V 1,5Ah
LE/80/2 6 – 80 2 PT Ni-Cd 6,0V 2,5Ah
LE/80/3 6 – 80 3 PT Ni-Cd 6,0V 4,0Ah

58
emergency conversion kits
LIDER PLUS & LIDER PLUS AUTOTEST

MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz
LIGHT SOURCE:
Linear and compact fluorescent lamps
CHARGING:
Maximum 12h; electronic energy-saving impulse charger
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-Cd or Ni-MH battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷55°C

35
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:

42
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Cooperation with magnetic and electronic ballasts
157
Optional adaptation of conversion kit for low temperatures up to -25°C

220-240V
Ni-Cd Ni-MH
AC IP20
50-60Hz

LIDER PLUS - ORDER CODES LIDER Ni-MH - ORDER CODES


CODE POWER [W] AUTONOMY [h] OPTION BATTERY CODE POWER [W] AUTONOMY [h] OPTION BATTERY
LEP/36/1 6 – 36 1 PT Ni-Cd 3,6V 1,5Ah LEH/36/1 6 – 36 1 PT Ni-MH 3,6V 1,5Ah
LEP/36/2 6 – 36 2 PT Ni-Cd 3,6V 2,5Ah LEH/36/2 6 – 36 2 PT Ni-MH 3,6V 2,5Ah
LEP/36/3 6 – 36 3 PT Ni-Cd 3,6V 4,0Ah LEH/36/3 6 – 36 3 PT Ni-MH 3,6V 4,0Ah
LEP/58/1 6 – 58 1 PT Ni-Cd 4,8V 1,5Ah LEH/58/1 6 – 58 1 PT Ni-MH 4,8V 1,5Ah
LEP/58/2 6 – 58 2 PT Ni-Cd 4,8V 2,5Ah LEH/58/2 6 – 58 2 PT Ni-MH 4,8V 2,5Ah
LEP/58/3 6 – 58 3 PT Ni-Cd 4,8V 4,0Ah LEH/58/3 6 – 58 3 PT Ni-MH 4,8V 4,0Ah
LEP/80/1 6 – 80 1 PT Ni-Cd 6,0V 1,5Ah LEH/80/1 6 – 80 1 PT Ni-MH 6,0V 1,5Ah
LEP/80/2 6 – 80 2 PT Ni-Cd 6,0V 2,5Ah LEH/80/2 6 – 80 2 PT Ni-MH 6,0V 2,5Ah
LEP/80/3 6 – 80 3 PT Ni-Cd 6,0V 4,0Ah LEH/80/3 6 – 80 3 PT Ni-MH 6,0V 4,0Ah

LEP PLUS AUTOTEST - ORDER CODES LIDER Ni-MH AUTOTEST - ORDER CODES
CODE POWER [W] AUTONOMY [h] BATTERY CODE POWER [W] AUTONOMY [h] BATTERY

LEP/36/1/AT 6 – 36 1 Ni-Cd 3,6V 2,5Ah LEH/36/1/AT 6 – 36 1 Ni-MH 3,6V 2,5Ah

LEP/36/2/AT 6 – 36 2 Ni-Cd 3,6V 4,0Ah LEH/36/2/AT 6 – 36 2 Ni-MH 3,6V 4,0Ah

LEP/36/3/AT 6 – 36 3 Ni-Cd 3,6V 4,0Ah LEH/36/3/AT 6 – 36 3 Ni-MH 3,6V 4,0Ah

LEP/58/1/AT 6 – 58 1 Ni-Cd 4,8V 2,5Ah LEH/58/1/AT 6 – 58 1 Ni-MH 4,8V 2,5Ah

LEP/58/2/AT 6 – 58 2 Ni-Cd 4,8V 4,0Ah LEH/58/2/AT 6 – 58 2 Ni-MH 4,8V 4,0Ah

LEP/58/3/AT 6 – 58 3 Ni-Cd 4,8V 4,0Ah LEH/58/3/AT 6 – 58 3 Ni-MH 4,8V 4,0Ah

LEP/80/1/AT 6 – 80 1 Ni-Cd 6,0V 2,5Ah LEH/80/1/AT 6 – 80 1 Ni-MH 6,0V 2,5Ah

LEP/80/2/AT 6 – 80 2 Ni-Cd 6,0V 2,5Ah LEH/80/2/AT 6 – 80 2 Ni-MH 6,0V 2,5Ah

LEP/80/3/AT 6 – 80 3 Ni-Cd 6,0V 4,0Ah LEH/80/3/AT 6 – 80 3 Ni-MH 6,0V 4,0Ah

Test types (version AT):


LED indicator
LED color Signal Symbolizing Test A is run automatically every Test B is run automatically every
30 days 360 days
no signal emergency mode / running test
During test A a conversion kit is During test B a conversion kit is
shining defective battery
switched to emergency mode switched to emergency mode for all
flashing defective lamp for 5 minutes and the following duration time (1, 2, 3 hours) and the
no signal emergency mode / running test parameters are checked: following parameters are checked:
• control of battery power discharge • control of battery power discharge
shining normal mode
• control of battery voltage • control of minimum battery voltage

59
emergency conversion kits
LIN

MATERIALS:
White polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz
LIGHT SOURCE:
Linear fluorescent T5 lamp
CHARGING:
Maximum 12h; electronic energy-saving impulse charger

30
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-MH battery (optionally Ni-Cd battery*)
INSULATION CLASS:
II
IP RATING:
IP20

22
AMBIENT TEMPERATURE:
ta: 0°C÷55°C
OPTIONS: 284
PT – manual test button
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection 220-240V
Ni-Cd Ni-MH
AC IP20
Cooperation with magnetic and electronic ballasts 50-60Hz
Optional adaptation of conversion kit for low temperatures up to -25°C
Long life of the LF lamp due to the function of the preheating of electrodes
Stabilization of lightstream

LIN – ORDER CODES


CODE POWER [W] AUTONOMY [h] BATTERY
LN/21/1 8,14,21 1 Ni-MH 3,6V 1,5Ah
LN/21/2 8,14,21 2 Ni-MH 3,6V 2,5Ah
LN/21/3 8,14,21 3 Ni-MH 3,6V 4,0Ah
LN/39/1 24,39 1 Ni-MH 4,8V 1,5Ah

LN/39/2 24,39 2 Ni-MH 4,8V 2,5Ah

LN/39/3 24,39 3 Ni-MH 4,8V 4,0Ah


LN/49/1 28,35,49 1 Ni-MH 6,0V 1,5Ah
LN/49/2 28,35,49 2 Ni-MH 6,0V 2,5Ah
LN/49/3 28,35,49 3 Ni-MH 6,0V 4,0Ah
LN/80/1 54,80 1 Ni-MH 6,0V 1,5Ah
LN/80/2 54,80 2 Ni-MH 6,0V 2,5Ah
LN/80/3 54,80 3 Ni-MH 6,0V 4,0Ah

*Emergency conversion kits series LIN can be optionally


equipped with a Ni-Cd battery. In this case, please add the
letter C at the end, for example: LN/49/1/C.

60
emergency conversion kits
LINEX & LINEX AUTOTEST

MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz
LIGHT SOURCE:
Linear fluorescent T5 lamp
CHARGING:
Maximum 12h; electronic energy-saving impulse charger

30
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-MH battery (optionally Ni-Cd battery*)
INSULATION CLASS:
II
IP RATING:
IP20

22
AMBIENT TEMPERATURE:
ta: 0°C÷55°C
OPTIONS: 284
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 220-240V
Ni-Cd Ni-MH
AC IP20
Deep discharge protection 50-60Hz
Cooperation with magnetic and electronic ballasts
Optional adaptation of conversion kit for low temperatures up to -25°C
Long life of the LF lamp due to the function of the preheating of electrodes
Stabilization of lightstream

LINEX – ORDER CODES


CODE POWER [W] AUTONOMY [h] OPTION BATTERY
LX/21/1 8,14,21 1 PT Ni-MH 3,6V 1,5Ah
LX/21/2 8,14,21 2 PT Ni-MH 3,6V 2,5Ah
LX/21/3 8,14,21 3 PT Ni-MH 3,6V 4,0Ah
LX/39/1 24,39 1 PT Ni-MH 4,8V 1,5Ah
LX/39/2 24,39 2 PT Ni-MH 4,8V 2,5Ah
LX/39/3 24,39 3 PT Ni-MH 4,8V 4,0Ah
LX/49/1 28,35,49 1 PT Ni-MH 6,0V 1,5Ah
LX/49/2 28,35,49 2 PT Ni-MH 6,0V 2,5Ah
LX/49/3 28,35,49 3 PT Ni-MH 6,0V 4,0Ah
LX/80/1 54,80 1 PT Ni-MH 6,0V 1,5Ah Test types (version AT):

LX/80/2 54,80 2 PT Ni-MH 6,0V 2,5Ah


Test A is run automatically every 30 days
LX/80/3 54,80 3 PT Ni-MH 6,0V 4,0Ah
During test A a conversion kit is switched
to emergency mode for 5 minutes and the
LINEX AUTOTEST – ORDER CODES following parameters are checked:
• control of battery power discharge
CODE POWER [W] AUTONOMY [h] BATTERY
• control of battery voltage
LX/21/1/AT 8,14,21 1 Ni-MH 3,6V 1,5Ah
LX/21/2/AT 8,14,21 2 Ni-MH 3,6V 2,5Ah Test B is run automatically every 360 days
LX/21/3/AT 8,14,21 3 Ni-MH 3,6V 4,0Ah During test B a conversion kit is switched to
LX/39/1/AT 24,39 1 Ni-MH 4,8V 1,5Ah emergency mode for all duration time
(1, 2, 3 hours) and the following parameters
LX/39/2/AT 24,39 2 Ni-MH 4,8V 2,5Ah
are checked:
LX/39/3/AT 24,39 3 Ni-MH 4,8V 4,0Ah
• control of battery power discharge
LX/49/1/AT 28,35,49 1 Ni-MH 6,0V 1,5Ah • control of minimum battery voltage
LX/49/2/AT 28,35,49 2 Ni-MH 6,0V 2,5Ah
LX/49/3/AT 28,35,49 3 Ni-MH 6,0V 4,0Ah
LED indicator
LX/80/1/AT 54,80 1 Ni-MH 6,0V 1,5Ah
LED color Signal Symbolizing
LX/80/2/AT 54,80 2 Ni-MH 6,0V 2,5Ah
LX/80/3/AT 54,80 3 Ni-MH 6,0V 4,0Ah no signal emergency mode / running test

shining defective battery

flashing defective lamp


*Emergency conversion kits series LINEX can be optionally no signal emergency mode / running test
equipped with a Ni-Cd battery. In this case, please add the let-
shining normal mode
ter C at the end, for example: LX/49/1/C.

61
emergency conversion kits
UNILED BM

MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz; 216 VDC
LIGHT SOURCE:
1W, 3W, 6W* LED
CHARGING:
Maximum 12h; electronic energy-saving impulse charger
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-MH battery (optionally Ni-Cd battery)
INSULATION CLASS:

22
II
IP RATING:
IP20
AMBIENT TEMPERATURE:

38
ta: 0°C÷40°C
OPTIONS:
PT – manual test button 134
AT – autotest
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection 220-240V
Ni-Cd Ni-MH
Optional adaptation of conversion kit for low temperatures up to -25°C AC IP20
50-60Hz
Automatic detection of battery capacity and setting test parameters
Output voltage: 3.3 VDC
* 6W – power of light source only in non-maintained fixtures

Uniled BM – ORDER CODES


CODE POWER [W] AUTONOMY [h] BATTERY
BM/1/1 1 Ni-MH 4,8V 1,0Ah
BM/1/2 2 Ni-MH 4,8V 1,0Ah
1
BM/1/3 3 Ni-MH 4,8V 1,5Ah
BM/1/8 8 Ni-MH 4,8V 3,0Ah
BM/3/1 1 Ni-MH 4,8V 1,5Ah
BM/3/2 3 2 Ni-MH 4,8V 2,5Ah
BM/3/3 3 Ni-MH 4,8V 3,0Ah
BM/6/1 1 Ni-MH 4,8V 3,0Ah
BM/6/2 6 2 Ni-MH 4,8V 5,0Ah
BM/6/3 3 Ni-MH 4,8V 8,0Ah

Uniled BM AUTOTEST – ORDER CODES


CODE POWER [W] AUTONOMY [h] BATTERY
BM/1/1/AT 1 Ni-MH 4,8V 1,0Ah
BM/1/2/AT 2 Ni-MH 4,8V 1,0Ah
1
BM/1/3/AT 3 Ni-MH 4,8V 1,5Ah
BM/1/8/AT 8 Ni-MH 4,8V 3,0Ah
BM/3/1/AT 1 Ni-MH 4,8V 1,5Ah
BM/3/2/AT 3 2 Ni-MH 4,8V 2,5Ah
BM/3/3/AT 3 Ni-MH 4,8V 3,0Ah
BM/6/1/AT 1 Ni-MH 4,8V 3,0Ah
Test types (version AT):
BM/6/2/AT 6 2 Ni-MH 4,8V 5,0Ah
BM/6/3/AT 3 Ni-MH 4,8V 8,0Ah Test A is run automatically every 28 days
During test A a conversion kit is switched to emergency mode
for 1 minute and the following parameters are checked:
LED indicator • control of battery power discharge
LED color Signal Symbolizing • control of battery voltage
no signal emergency mode / running test
Test B is run automatically every 364 days
shining defective battery
During test B a conversion kit is switched to emergency
flashing defective lamp mode for all duration time (1, 2, 3 hours) and the following
no signal emergency mode / running test parameters are checked:
• control of battery power discharge
shining normal mode
• control of minimum battery voltage

62
emergency conversion kits
UNILED GU10

MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
230VAC/50-60Hz
LIGHT SOURCE:
3,5–8W LED
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h or 3h; Ni-Cd battery
INSULATION CLASS:

35
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C

42
OPTIONS:
PT – manual test button
ADDITIONAL INFORMATION: 157
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Designed for cooperation with LED light sources with voltage 180VDC 230V
Ni-Cd
In emergency mode light stream is 80% of the nominal stream AC IP20
50-60Hz

Uniled GU10 – ORDER CODE


CODE POWER [W] AUTONOMY [h] OPTION BATTERY
GU10/1 3,5 – 8 1 PT Ni-CD 7,2V 1,5Ah
GU10/2 3,5 – 8 3 PT Ni-CD 7,2V 4,0Ah

63
emergency conversion kits
UNILED UM

MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240VAC/50÷60Hz
LIGHT SOURCE:
Power mode: max 80W
Voltage mode: max 9W
Designed for cooperation with LED light sources with voltage 12V - 90VDC - max 80W
OUTPUT POWER:
1 - 9W (10mA - 750mA)

35
CHARGING:
Maximum 12h or 24h; depending on battery capacity
AUTONOMY & BATTERIES:
1h, 3h lub 8h, Batteries Ni-MH, Ni-Cd
Autonomy 1h, 3h, 8h set by jumper

42
INSULATION CLASS:
II
IP RATING: 157
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷50°C
OPTIONS: 220-240V
Ni-Cd Ni-MH
PT – manual test button AC IP20
50-60Hz
AT – autotest
RS – Rubic central monitoring
ADDITIONAL INFORMATION:
Deep discharge protection
Optional adaptation of conversion kit for low temperatures up to -25°C
Automatic detection of battery capacity and setting test parameters
Automatic detection of LED light source voltage in Power mode
In emergency mode (Power or Voltage), the incorrect settings
are detected by LED indicator

POWER MODE Settings

LED Power mode, choice of output power


power supply UNILED UM in the range: 1W - 9W
max. 80W

AUTONOMY [h]
Type of battery
1h 3h 8h

7,2V 1000mAh 3W 1W –
Ni-MH/Ni-Cd

7,2V1500 mAh 4W 2W 1W OFF


7,2V 2500mAh 8W 3W 1W

7,2V 4000mAh 9W 5W 2W

7,2V 8000mAh 9W 9W 4W

Light output in emergency mode (only power mode)

=
light output in emergency mode LED power in emergency mode

light output in mains mode LED power in mains mode

=
LED power in emergency mode [W]
light output in emergency mode [lm] x light output in mains mode [lm]
LED power in mains mode [W]

64
emergency conversion kits
Voltage mode Settings

LED
UNILED UM power supply
max. 9W

OFF

Voltage mode, choice of output voltage


in the range: 12V - 90V

Autonomy 1h Autonomy 3h Autonomy 8h


POWER SUPPLY VOLTAGE [V] POWER SUPPLY VOLTAGE [V] POWER SUPPLY VOLTAGE [V]
Type of battery
12 24 36 48 60 90 12 24 36 48 60 90 12 24 36 48 60 90

7,2V 1500mAh 0,41 0,20 0,14 0,10 0,08 0,05 0,41 0,08 0,06 0,04 0,03 0,02 0,41 0,03 0,02 0,02 0,01 0,01
Ni-MH/Ni-Cd

7,2V 2500mAh 0,68 0,34 0,23 0,17 0,14 0,09 0,28 0,14 0,09 0,07 0,06 0,04 0,11 0,06 0,04 0,03 0,02 0,02
7,2V 4000mAh 0,75 0,54 0,36 0,27 0,22 0,14 0,45 0,23 0,15 0,11 0,09 0,06 0,18 0,09 0,06 0,05 0,04 0,02

7,2V 8000mAh 0,75 0,75 0,72 0,54 0,43 0,29 0,75 0,45 0,30 0,23 0,18 0,12 0,36 0,18 0,12 0,09 0,07 0,05

CONFIGURATION OF CONVERSION KIT CONFIGURATION OF BATTERY PACKAGES


BATTERY
CODE OPTION
CAPACITY TYPE PACKAGES

UM 10 CD MH B1 B2 B3 PT AT RS

UM 15 CD MH B1 B2 B3 PT AT RS
UM 25 CD MH B1 B2 B3 PT AT RS

UM 40 CD MH B1 B2 B3 PT AT RS

UM 80 CD MH B1 B2 B3 PT AT RS

LED indicator Test types (version AT):


LED color Signal Symbolizing
Test A is run automatically every 28 days
no signal emergency mode / running test
During test A a conversion kit is switched to emergency mode
shining defective battery for 1 minute and the following parameters are checked:
flashing defective lamp • control of battery power discharge
• control of battery voltage
no signal emergency mode / running test

shining normal mode Test B is run automatically every 364 days


During test B a conversion kit is switched to emergency
mode for all duration time (1, 2, 3 hours) and the following
parameters are checked:
Legend: • control of battery power discharge
PT – manual test button • control of minimum battery voltage
AT – autotest
RS – Rubic central monitoring
UM – conversion kit Uniled UM
10 – battery capacity 1000 mAh
15 – battery capacity 1500 mAh
25 – battery capacity 2500 mAh
40 – battery capacity 4000 mAh
80 – battery capacity 8000 mAh
CD – battery type Ni-Cd
MH – battery type Ni-MH
B1 – battery Stick
B2 – battery Akku Pack
B3 – battery Akku Pack block

65
systems

RUBIC UNA 68
RUBIC MINI UNA 69
Central Battery system FZLV 70
Central battery system LPS 72
Central Battery system CBS 74
SMART VISIO PLATFORM 76

RUBIC UNA RUBIC MINI UNA Central Central Central SMART VISIO
Battery battery Battery PLATFORM
system FZLV system LPS system CBS
systems
RUBIC UNA

The most important parameters:

• Touch panel
• Unique addresses of luminaires
• Address programmer not required
• Proper polarization of connection of bus communication line is not
required
• Legible, big touchscreen LCD with a simple menu
• 4 potential-free 24V inputs
• 4 potential-free 24V outputs
• RJ45 connector for direct communication with any computer via
Ethernet,
• Preview of the system via any web browser
• Monitoring up to 750 of emergency fittings
• The quantity of the monitored fittings within one system can be
expanded up to 4000 emergency fittings
• Displaying the current system state
• Monitor emergency luminaires equipped with autonomous power
The Rubic UNA system is the latest and the most advanced version of supply RS sources, both fluorescent and LED
the monitoring system which controls independent fittings of emergency • Internal battery supporting power supply of the central unit
and evacuation lighting. Each control unit can control up to 4000 fittings • Automated testing
by using MPU250 submodules. Submodules communicate with the central • SD card slot and card itself allow to save the periodic test results, event
RUBIC UNA via LAN. Due to the connection through the LAN it is possible log and system configuration, in accordance with EN 50172
to use the Wi - Fi connection between the submodules. • Posiibility to test the fittings individually or in a group
• Night operation mode activated with one digital button
RUBIC UNA has a touch panel with graphical, intuitive menu. This • Management and visualization of the system using dedicated software
allows you to configure the system in a simply and easy way without the SMART VISIO
use of SmartVISIO application. • Works with any BMS (Building Management System) by using the
Due to applied technical solutions, we have eliminated the importance potential-free contacts.
of polarization of connecting the communication bus directly to:
• RUBIC UNA central unit
• MP UNA submodules
• RS address modules

Each RS address module has its own individual number / address.


Addresses are assigned by the factory therefore no additional devices,
such as address programmers, are required.

RS485
max. 1200m

06.001 06.002 06.003 06.091


00-0A-2A3A-F001 00-1A-1F1A-0001 00-00-1F1D-F001 00-10-1F2C-F021
RS485
max. 1200m

05.001 05.002 05.007 05.211


MP UNA 00-0A-214C-F001 00-1A-141C-0120 00-00-113F-C201 00-10-12CC-F321

RS485
max. 1200m

04.001 04.043 04.123 04.240


MP UNA 00-2A-231A-F022 00-1A-131A-0143 00-00-311D-F029 00-10-322C-F028
LAN
max. 100m
LAN
RUBIC UNA RS485
max. 1200m
max. 100m

03.001 03.003 03.031


ROUTER 00-1A-145A-0143 00-00-115D-F029 00-10-126C-F027
RS485
max. 1200m

02.001 02.033 02.123


00-1A-144A-0143 00-00-141D-F029 00-10-142C-F023
RS485
max. 1200m

01.001 01.010 01.123


INTERNET 00-1A-121A-0143 00-00-121D-F029 00-10-132C-F023

PC WWW

68
systems
RUBIC MINI UNA

The most important parameters:

• Monitoring up to 500 emergency fittings


• The maximum length of a single bus is 1200 m
• LEDs signalling status of the system
• 3 function keys
• 2 potential-free 24V inputs
• 2 potential-free 24V outputs
• Internal memory stores the reports of emergency lighting system in
accordance with EN 50172
• Night operation mode
• Possibility to test the fittings individually or in a group
• Internal battery supporting power supply of the central unit
RUBIC MINI is a compact solution dedicated to monitoring addressable • RJ45 connector for direct communication with any computer via
emergency lighting in buildings of small and medium size. The system is Ethernet
designed to monitor up to 500 emergency luminaires equipped with • Individual IP address
autonomous power supply RS sources, both fluorescent and LED. • Preview of the system via any web browser

The main advantages of the control unit are its small size and the
possibility of direct mounting on TH-35 rail (DIN-3). The system is maximally
simplified but has all the key features from the point of view of the user.
Each control unit is equipped with an input bus RS, RJ45 connector, three
LEDs indicating the status of the system, the reset button and the service
pin which is used to personalize the new IP address. Communication
with emergency RS luminaires is carried out by bus RS485 conducted
in RS485 standard. Length of a single bus in linear topology is 1200 m.
Communication with the luminaires is continuous.

RS485
max. 1200m

01.001 01.002 01.003 01.099 01.100


00-0A-139A-F001 00-0B-C21A-0020 00-01-1A1F-F001 00-00-1C2C-F001 00-01-1A0D-F0FF

RS485
max. 1200m

02.001 02.033 02.123 02.240


00-0A-132A-F091 00-0A-141A-9000 00-00-122C-F901 00-00-122C-F001

RUBIC MINI UNA

LAN
max. 100m

ROUTER
INTERNET PC WWW

LAN
max. 100m

PC

69
systems
Central Battery system FZLV

Central battery system FZLV is a high-tech device created to power fittings and the introduction of all settings and parameters of the system
and monitor emergency lighting in buildings of small and medium size and with the use of the user interface. Statuses are displayed in both graphic
in closed fire zones. The  system can work with up to 80 LED luminaires and text form. Using the central unit one can assign a name to the fitting
supplied by SELV 24V (Safety Extra-Low Voltage) and was designed in that will clearly help to identify the fittings installed in the system. Using the
SMART technology. central unit one can program and freely configure the emergency fittings
in constant, non-constant, switching and switching-dimming modes as well
The application of the SELV voltage ensures high level of safety of as night work mode. The system has its own IP address and RJ45 slot which
servicing of the system and its elements are compilant with the currently is used for direct connection to Ethernet. With an built-in WEB module you
valid regulations. Small dimensions of the central unit enable the can directly access the system from any computer and print the event log
installation of the system in places where one cannot fit a large-size central by using any web browser. Additionally, the system has an input and an SD
battery system. The FZLV central unit is equipped with a big touch panel card that allows to record and upload system settings (back-up) and the
enabling both the current reading of the status of the system, circuits and record of the reports of the Event Log in accordance with EN 50172.

FZLV - 12 Ah FZLV - 24 Ah FZLV - MAX 26/52 Ah

1....20 1....20

1....20 1....20

FIRE ZONE FIRE ZONE

1....20 1....20

1....20 1....20

FIRE ZONE FIRE ZONE

1....20 1....20
1....20 1....20

PH90*

STAIRS FIRE ZONE FIRE ZONE

70
systems
The most important parameters:
• Possibility to store the system settings (back – up) on SD card
• Power supply and monitoring up to 80 individual LED fittings in SMART • Contained security light mode (night operation)
technology • Possibility to control fittings and some functions of the system via
• Safe supply SELV 24V terminals 24V and 230V
• SMART technology – any mode of a fitting • Testing of each fitting separately as well as group of fittings
• Easy to read, big LCD touch screen • Internal rechargeable battery with a designed life of 10 years
• Easy and intuitive menu with simple icons • RJ45 slot for direct connection to Ethernet
• Automated testing • Individual IP address
• Automatic detection and adding of the fittings to the system • Preview of the system via any web browser
• Built-in WEB module • Works with any BMS (Building Management System) by using the
• Programming and configuration of the fittings directly from the system module of potential-free contacts or a CAN-bus
• Communication with luminaires through the power supply cable • Unlimited grouping of systems and joint supervision by Smart Touch
• SD slot and SD card for recording, transmission and printing emergency Controller
lighting reports from any PC, in accordance with EN 50172 • Programmable emergency time operation for individual fixtures

SMART VISIO WEB SMART VISIO

access point

INTERNET
ROUTER

MAX 100m
MAX 100m
MAX 100m
MAX 100m
MAX 100m
MAX 100m

MAX 100m

1....20 1....20

1....20 1....20

FIRE ZONE FIRE ZONE

1....20 1....20

1....20 1....20

FIRE ZONE FIRE ZONE

1....20 1....20
1....20 1....20

PH90*

STAIRS FIRE ZONE FIRE ZONE

71
systems
Central battery system LPS

The LPS central battery system, offered by AWEX, is a small, The system enables emergency supplying of the fittings with a total
up-to-date, reliable and simple device. It has been designed in accordance power of 1500W for the time of 1h, or the fittings 500W - for 3h. With four
with the he applicable standards and with using SMART technology. Its sensor inputs installed in the steering module it is possible to control
functions are equivalent to the functions of CBS system, however, due fire zones through the use of sensors decay phases (CFZ), which control
to its small size and limited power the system is suitable for installation power supply to the switch board of power supply zone. In addition, the
in smaller buildings or buildings that require diversification of source of system can be expanded by ELS-230 modules, with nine voltage control
supply of emergency fittings (as a group system). inputs. Linear modules have separate protection for AC and DC mode, this
significantly increases the safety level of switching the emergency mode
in the building. In the emergency mode, the system works in IT network
(isolated system).

System LPS

72
systems
The most important parameters:

• LCD display with easy-to-use menu • Possibility to record the back-up of the system on the SD card
• Automatic test performing • Night mode operation
• Automatic detection and adding luminaires to the system • Possibility to control luminaires and functions of the system through the
• Monitoring of each luminaire 24V and 230V internal and external connectors
• Monitoring of each circuit • Possibility to monitor power in the distribution boards and in the
• Programming and configuration of the luminaires directly from the separate lighting circuits
central unit • USB slot
• Communication with luminaires through the power cable • RJ45 connector for direct communication with any computer via
• SMART technology – any mode of operation of the luminaire Ethernet
• The linear modules are secured for the AC and DC mode separatelly • Preview of the system via any web browser
• SD card slot and card itself allow to save the periodic test results, event • Management and visualization of the system by using dedicated
log and system configuration software SMART VISIO
• Supply of the fixtures of total capacity 1500W for time 1h or 500W for 3h

LON/LAN
LON/LAN
LON/LAN
SUPPLY

73
systems
Central Battery system CBS

The CBS central battery system is state-of-the-art, reliable and easy- the periodic test results, event log and system configuration, in accordance
to-operate central battery system constructed in accordance with the with EN 50172. The event log can be printed out of the SD card on any
requirements of VDE 0108 as well as EN 50171 and EN 50172 standards. PC without any additional software. Besides, all the settings are stored in
Due to the possibility of using sub-modules it is dedicated to medium and non-volatile memory and will not be lost even during the complete power
large buildings and was designed in SMART technology. supply and battery failure. The charger module ensures battery charging
based on UI characteristics with temperature compensation according
The system monitors each output circuit individually and with the use to EN 50171. The charger is equipped with internal active PFC module
of address modules – each luminaire. The system allows any configuration which provides a power factor close to 1. Linear modules have separate
of mode both of the circuit and the luminaire. Using the driver one can protection for AC and DC mode, significantly increasing the safety level
programme the mode of the address module without interfering into the while switching on emergency lighting in the building. In DC mode the
luminaire and without any specialized service software. The SD card slot system works in IT network layout (isolated system).
used in the system allows to perform a backup of the system and to save

System CBS Compact

System CBS Standard

74
systems
The most important parameters:

• LCD display with easy-to-use menu • Night mode operation


• Automatic test performing • Possibility to control luminaires and functions of the system through the
• Automatic detection and adding luminaires to the system 24V and 230V internal and external connectors
• Monitoring of each luminaire • Possibility to monitor power in the distribution boards and in the
• Monitoring of each circuit separate lighting circuits
• Programming and configuration of the luminaires directly from the • Possibility to use sub-modules in standard version and HUB version
central unit • USB slot
• Communication with luminaires through the power cable • RJ45 connector for direct communication with any computer via
• SMART technology – any mode of operation of the luminaire Ethernet
• The linear modules are secured for the AC and DC mode separatelly • Preview of the system via any web browser
• SD card slot and card itself allow to save the periodic test results, event • Battery set with 10 years life-time
log and system configuration, • Works with any BMS (Building Management System) by using the
• Possibility to record the back-up of the system on the SD card potential-free contacts
• Management, supervision and visualization of entire system via
dedicated SMART VISIO software

MAIN STATION CIRCUITS SUB-STATION CIRCUITS


signal which controls circuit CB/02
L=230V

CB/02 monitoring of circuits

CB/02 CB/02 (n=MAX 20 OR 6A) PBS/01/n (n=MAX 20) PBS/01/03 PBS/01/02 PBS/01/01

CB/01/01 CB/01/02 CB/01/03 CB/01/n (n=MAX 20) PBS/02/n (n=MAX 20) PBS/02/03 PBS/02/02 PBS/02/01
CB/01 monitoring of luminaires
(combined mode)

AC - 230V PBS/02 - monitoring of luminaires

lon

lon dc - 216V PBS/01 - monitoring of luminaires


(combined mode)
LAN

AC - 230V

mains 230V

ELS-230 external module Phase loss sensor


pbs Phase loss sensor

Cooperation with BMS system

Monitoring
L1, L2, L3 230V
cbs Monitoring
L1, L2, L3 230V
Remote control panel smart visio Monitoring
L1, L2, L3 230V

75
systems
THE SMART VISIO PLATFORM

SMART VISIO application is an advanced supervising and managing implemented in most of the buildings. Due to the low installation costs,
software created by AWEX for the latest emergency lighting systems. the possibility of full visualization and minimum time necessary for the
Regardless of the choice of the system (FZLV, LPS, CBS, RUBIC UNA) SMART daily inspection of emergency lighting, SMART VISIO is recommended for
VISIO allows you to connect, group and visualize each of them at the same shopping malls, medium and large office buildings, hospitals, stadiums,
time and in any configuration, from one place. By using a common LAN airports factories and other buildings.
standard to communicate with the systems, the software is easy to be

Properties:

• suitable for 4 different types of systems produced by AWEX


• intuitive interface
• possibility to upload layouts of the building
• system condition supervision
• system configuration
• event log readout
• full testing facilities

SMART VISIO APPLICATION

PC

LAN LAN
max. 100m max. 100m

ROUTER

CBS LPS FZLV RUBIC UNA

76
systems

The structure of the system is represented as a tree and as panels with


tabs. The order of elements is not set manually by a user, but is a result
of addressing. The number and contents of tabs depend on the element
of the system currently selected. Each element has a tab that displays its
status.

In the tree of the system, one of the systems can be selected and its status
will be shown on the panel. If the System is chosen, the status of all the
central units will be seen (icons change color the same way as on the plan
of the building). To change the current settings, use “Settings” tab.

RUBIC panel allows you to see the status of Rubic UNA or Rubic UNA MINI
central unit, as well as conversion kits and luminaires connected to it, to
see the results of tests, reports and configuration of the central unit. The
diagram displays the software version, serial number, status of inputs,
outputs, errors, lock, night work, power status, charger status, battery
status. Icons indicate the status of groups and sub-modules.

FZLV panel allows observation of the FZLV central unit and the luminaires
connected to it, viewing test results, reports, graphs and configuration of
the central unit. The diagram shows the hardware and software version,
serial number, status of inputs, outputs, errors, lock, night work, total
status of the central unit, power status, charger status, battery status,
circuit status.

CBS panel allows observation of status of the central battery, control unit,
charger, sensor modules, linear modules and luminaires, view test results,
reports. The diagram shows a view of the central battery cabinet. Modules
inside the cabinet can be moved by dragging the module with a mouse,
left button pressed. The control module is shown as CM (Control Module),
charger is shown as CH (Charger). The status of the groups (G1 - G255) is
displayed in the table named Steering Groups. The list displays the status
of the linear modules LM (Linear Module) and sensor modules SM (Sensor
Module).

77
additional components

HTR 25 - HEATER WITH THERMOSTAT


FOR LOW TEMPERATURE 80
Accessories81
BATTERIES82
pictograms83

HTR 25 Accessories BATTERIES pictograms


HEATER WITH
THERMOSTAT
additional components
HTR 25 - HEATER WITH THERMOSTAT
FOR LOW TEMPERATURE

System HTR-25 allows our emergency lighting fixtures to work in up to


-25°C, which makes our products suitable for installation in cold rooms,
parkings and outside of the buildings where self-contained emergency
lighting fixtures are exposed to low temperatures.
This innovative solution can be used with both NiCd and Ni-MH battery
packs, with fluorescent tubes and with LED’s. HTR-25 is suitable for AWEX’s
IP65 fixtures and for our conversion kits assembled in IP65 commercial
lighting.

TECHNICAL SPECIFICATION:
Power supply: 230 VAC/50 Hz
Insulation class: I
Minimal ambient temperature: -25°C
Minimal battery temperature: +6°C
Heater initiation temperature: <10°C

4
2
L
N
PE

Legend:
1. Thermostat NO – closing temperature 10°C ±5°C – assembled inside the fixture
2. Thermostat NC – opening temperature 60°C ± 5°C – assembled on the battery
3. Self-regulated heating wire
4. Battery pack

ORDER CODES

CODE BATTERY CAPACITY BATTERY TYPE CODE BATTERY CAPACITY BATTERY TYPE
HTR-25/3.6-1000-CD 3.6V 1000mAh Ni-Cd HTR-25/3.6-1000-MH 3.6V 1000mAh Ni-MH
HTR-25/3.6-1500-CD 3.6V 1500mAh Ni-Cd HTR-25/3.6-1500-MH 3.6V 1500mAh Ni-MH
HTR-25/3.6-2500-CD 3.6V 2500mAh Ni-Cd HTR-25/3.6-2500-MH 3.6V 2500mAh Ni-MH
HTR-25/3.6-4000-CD 3.6V 4000mAh Ni-Cd HTR-25/3.6-4000-MH 3.6V 4000mAh Ni-MH
HTR-25/4.8-1500-CD 4.8V 1500mAh Ni-Cd HTR-25/4.8-1500-MH 4.8V 1500mAh Ni-MH
HTR-25/4.8-2500-CD 4.8V 2500mAh Ni-Cd HTR-25/4.8-2500-MH 4.8V 2500mAh Ni-MH
HTR-25/4.8-4000-CD 4.8V 4000mAh Ni-Cd HTR-25/4.8-4000-MH 4.8V 4000mAh Ni-MH
HTR-25/6.0-1500-CD 6.0V 1500mAh Ni-Cd HTR-25/6.0-1500-MH 6.0V 1500mAh Ni-MH
HTR-25/6.0-2500-CD 6.0V 2500mAh Ni-Cd HTR-25/6.0-2500-MH 6.0V 2500mAh Ni-MH
HTR-25/6.0-4000-CD 6.0V 4000mAh Ni-Cd HTR-25/6.0-4000-MH 6.0V 4000mAh Ni-MH

HTR 25 heating system type is designed for installation in luminaires with a degree of IP65 or higher.
HTR25 heating system type is designed for installation in luminaires with a degree of IP65 or higher.

80
additional components
Accessories

NAME/CODE PICTURE TECHNICAL DRAWING APPLICATION

300 30

128
CEILING BRACKET
HELIOS
CODE: 1902

300 30

115
WALL BRACKET
HELIOS
CODE: 1901

128

435
CEILING BRACKET WITH PIPE
HELIOS
CODE: 2944

300

348

WALL BRACKET
INFINITY AS, INFINITY AC, ESCAPE
CODE: 1011
45

110
325

WALL BRACKET
TWINS
CODE: 1009
120

SUSPENSION ROPES
120

SCREEN DS, TWINS


CODE: 1006
20

UNDER PLASTERING CLIPS


(SET OF 2 pcs) TIGER, TIGER DS, TIGER P
CODE:1010

135
120

EXTENSION BOX
LOVATO N
CODE: WWT 1000064
120

HELIOS, EMX ,PANORAMA


WIRE GUARD
HELIOS CODE: 1003 Dimensions:
EMX CODE: 1004 Helios: 405x100x170mm
PANORAMA CODE: 1005 Emx: 405x132x208mm
Panorama: 410x80x205mm

81
additional components
BATTERIES

DIMENSIONS [mm]
CODE CAPACITY [mAh] VOLTAGE [V] WEIGHT [Kg]
AxBxCxDxExF
1000 153x179x18x15x14x4 0,076
1500 136x162x25x22x18x4 0,14
Ni-Cd 3.6
2500 152x178x30x26x20x4 0,21
4000 189x210x30x33x25x4 0,352
1500 175x202x25x22x18x4 0,184
Ni-Cd 2500 4.8 202x228x30x26x20x4 0,288
4000 245x270x36x33x25x4 0,452
1500 218x244x25x22x18x4 0,228
Ni-Cd 2500 6.0 248x275x30x26x20x4 0,354
4000 303x329x36x33x25x4 0,574
1500 153x179x18x15x14x4 0,088
Ni-MH 2500 3.6 136x162x25xx22x18x4 0,172
4000 152x179x30x26x20x4 0,26
1500 202x228x18x15x14x4 0,114
Ni-MH 2500 4.8 175x202x25x22x18x4 0,22
4000 202x228x30x26x20x4 0,338
1500 251x276x18x15x14x4 0,14
Ni-MH 2500 6.0 220x246x26x23x18x4 0,268
4000 251x276x30x26x20x4 0,398
C

E
F

A
B

82
additional components
pictograms

22 23 24

25 26 27

28 29

61

PSxx PMxx PBxx PQxx


dimenssion [mm] 100x300 125x250 150x300 239x239

designed for TG, TL, TGS, TSL H, HE, HEL, HD, HDE, HDL, HDEL TP, TPL, HP, HPL, E, EL, TW, PL, IF, SK8 Q

Legend:
xx - number of pictogram (picture above)

83
Information for readers
Used symbols

The product meets the requirements in accordance with Light source type - LED
the European Directive LED

220-240V The permissible range of AC input voltage Light source type - fluorescent lamp T5
AC T5
50-60Hz G5

The permissible range of DC input voltage Protection class - IP65


175-275v
IP65
DC

Safety extra low voltage SELV Mounting of emergency escape lighting fittings - surface / ceiling
24V
DC

Insulation class I Mounting of emergency escape lighting fittings - recessed / ceiling

Insulation class II Mounting of emergency exit signs - recessed / ceiling

Insulation class III Mounting of emergency exit signs - surface / ceiling

Type of used battery Viewing distance d=25m


Ni-Cd
d=25m

Adaptation of the fixture for low temperatures up to -25°C

Emergency exit sign fitting, a pictogram


must be chosen

*see pictogram

The pictures and the parameters of the products contained in this catalogue shall be considered only a commercial information and do not constitute
an offer within the meaning of the law.
Some parameters of the delivered products may differ from the parameters of the products in this catalogue. Appearance of some products may differ
slightly from pictures and drawings represented in this catalogue. AWEX company reserves the right to withdraw products from catalogue or change
their parameters.

84
notes
P.P.H.U. AWEX Rafał Stanuch
Masłomiąca, ul. Długa 39
32-091 Michałowice, Poland
tel.: (+48) 12 681 55 00, fax: (+48) 12 681 55 26
e-mail: export@awex.eu
www.awex.eu

Das könnte Ihnen auch gefallen