The Forbes Marshall Safety Relief Valve FMSRV is a
high lift safety valve with gun metal seat, valve and body
and brass internals suitable for use on steam and water.
Size and Pipe Connections
DN 15
Screwed BSPT/BSP/NPT
Note : Available with IBR certificate
Limiting Conditions
Maximum blow off pressure 17.3 bar g No. Part Material Standard
1 Body G.M BS 1400
2 Valve Head G.M. BS 1440 LG 2
Operating Range
3 Spring Spring Steel I.S. 4454 part IV
4 Spindle Brass I.S.4170
5 Bonnet Brass I.S.4170
6 Adjustment Cap Brass I.S.4170
7 Lock Nut Brass I.S.4170
8 Ring C 20 I.S.2062
The product must not be used in this region.
9 Dowel Pin SS 304 ASTM A 276
Dimensions: (approx. ) in mm
15 87 23 30 0.42
500
The outlet from the safety valve should be arranged to
discharge to a safe place where it is visible but cannot
400
cause damage or injury to persons.
300
These valves are not suitable for mounting on
200 boilers.
100
0 How to Order
0 2 4 6 8 10 12 14 16 18
Example: Forbes Marshall Safety Valve, FMSRV ,
Set pressure in bar g DN15 with BSPT ends and a set pressure of 6 bar g.
Note : available with IBR certificates
Available Spares
Valve Head and Spindle Kit
WATER Spring Kit
7000
2000
1000
0
0 2 4 6 8 10 12 14 16 18
Set pressure in bar g
Opp 106th Milestone B-85, Phase II, Chakan Indl Area A-34/35, MIDC H Block
Bombay Poona Road Sawardari, Chakan, Tal. Khed Pimpri, Pune - 411 018. INDIA.
Kasarwadi, Pune - 411 034. INDIA Dist. Pune - 410 501. INDIA Tel : 91(0)20-27442020, 39851199
Forbes Marshall Tel : 91(0)20-27145595, 39858555 Tel : 91(0)2135-393400 Fax : 91(0)20-27442040
Krohne Marshall Fax : 91(0)20-27147413 CIN No.: U28996PN1985PTC037806
Forbes Marshall Arca Email : seg@forbesmarshall.com, ccmidc@forbesmarshall.com www.forbesmarshall.com
Codel International © All rights reserved. Any reproduction or distribution in part or as a whole without written permission of Forbes Marshall Pvt Ltd, its associate companies
Forbes Solar or its subsidiaries (“FM Group”) is prohibited.
Forbes Vyncke Information, designs or specifications in this document are subject to change without notice. Responsibility for suitability, selection, installation, use,
operation or maintenance of the product(s) rests solely with the purchaser and/or user. The contents of this document are presented for informational
Forbes Marshall Steam Systems purposes only. FM Group disclaims liabilities or losses that may be incurred as a consequence of the use of this information.
DOC# FMSS/0317/TIS-FMSRV/R1