Component :-
Corrosion Chemical High water temperature Heat transfer process disturbed Loss of Condenser
with improper chemistry Performance
Component :-
Component :-
Improper maintenance
Low Level Sea Water Vacuum priming pump
wear out
6 Hotwell structure Cracking of welds vibration Defect dissolved oxygen is high
Component :-
11 Hotwell A Level - Level To detect level of hotwell A Dirty Bad quality of demin water 4 N Unable to read the indicator Unable to detect the level
Gauge (10MAG10CL502) accurately accurately from
10MAG10CL502
Valve Leakage Gasket wear out 4 N House keeping issue
-
12 Condenser A Hotwell To detect condenser hotwell Bad wiring and connection Broken, loose, or 4 N Fail to detect hotwell level and Interlock to stop condensate
Level 1 - Differential level dan give interlock signal grounded give LL signal pump when '2/3' logic is met
Pressure Transmitter when the level is LL
(10MAG10CL104)
Bad sensing component of Component failure 4 N Fail to detect hotwell level and Interlock to stop condensate
transmitter give LL signal pump when '2/3' logic is met
Bad sensing lines Valve leakage 4 N Fail to detect hotwell level Interlock to stop condensate
pump when '2/3 LL signal' logic
is met
13 Condenser A Hotwell To detect condenser hotwell Bad wiring and connection Broken, loose, or 4 N Fail to detect hotwell level and Interlock to stop condensate
Level 2 - Differential level dan give interlock signal grounded give LL signal pump when '2/3' logic is met
Pressure Transmitter when the level is LL
(10MAG10CL105)
Bad sensing component of Component failure 4 N Fail to detect hotwell level and Interlock to stop condensate
transmitter give LL signal pump when '2/3' logic is met
Bad sensing lines Valve leakage 4 N Fail to detect hotwell level Interlock to stop condensate
pump when '2/3 LL signal' logic
is met
UNIT BISNIS OPERASI DAN PEMELIHARAAN PLTU BANTEN 1 SURALAYA
Component :-
Bad sensing component of Component failure 4 N Fail to detect hotwell level and Interlock to stop condensate
transmitter give LL signal pump when '2/3' logic is met
Bad sensing lines Valve leakage 4 N Fail to detect hotwell level Interlock to stop condensate
pump when '2/3 LL signal' logic
is met
Finishing Date :
Workshop Date :
Revision : 00
Dapat menyebabkan kerusakan pada Operator check, housekeeping Inspeksi SpS. Har. Mekanik
boiler tube
Maintenance check Inspeksi SpS. Har. Mekanik
Loss of Turbine Performance Maintenance check Inspeksi SpS. Har. Mekanik
Loss of Condenser Performance Maintenance check Eddy Current Test SpS. Har. Mekanik
Finishing Date :
Workshop Date :
Revision : 00
Workshop Date :
Revision : 00
Possibility of damaging the tubr boiler Maintenance check Inspeksi SpS. Har. Mekanik
Possibility of damaging the tubr boiler Maintenance check Inspeksi SpS. Har. Mekanik
Loss of condenser performance Operator check Online monitoring vacuum Operator CR.
Maintenance check Inspeksi SpS. Har. Mekanik
Loss of condenser performance Maintenance check Inspeksi SpS. Har. Mekanik
Loss of condenser performance Maintenance check Inspeksi SpS. Har. Mekanik
Operator check Operator rounds Operator Lokal
Workshop Date :
Revision : 00
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, SPS Har K&I
loop test)
Trip unit when '2/3 LL signal' logic is 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, SPS Har K&I
met loop test)
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, SPS Har K&I
loop test)
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, SPS Har K&I
loop test)
Trip unit when '2/3 LL signal' logic is 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, SPS Har K&I
met loop test)
Finishing Date :
Workshop Date :
Revision : 00
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, SPS Har K&I
loop test)
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, SPS Har K&I
loop test)
Trip unit when '2/3 LL signal' logic is 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, SPS Har K&I
met loop test)
UNIT BISNIS OPERASI DAN PEMELIHARAAN PLTU BANTEN 1 SURALAYA
Failure Effect on
No Item Identification Function Failure Mode Failure Cause OCC CRT Component or Functional Next Higher Assembly
Assembly (Equipment)
1 Housing Sebagai pelindung /casing Leaking Improper Installation 3 Kandungan oksigen tinggi pada
daripada condenser feedwater
Wall/Lining Damaged 4
2 Waterbox manways, Fasilitas untuk inspeksi Aging Failed welds 1
expansion seals, welds, condenser
and liner
Improper or failed cathodic Mechanical damage to 1
protection liner/coating
3 Expansion joint Sebagai pengaman Mechanical damage Improper Installation 3
4 Tube Sebagai media untuk Scalling or deposit High temperatur with 6 Heat transfer process disturbed
condensasi dan pendingin improper chemistry
Corrosion Chemical High water temperature 3 Heat transfer process disturbed Loss of Condenser
with improper chemistry Performance
Failure Effect on
No Item Identification Function Failure Mode Failure Cause OCC CRT Component or Functional Next Higher Assembly
Assembly (Equipment)
Erosion (internal) Flow accelerated corrosin 3 Tube rupture Heat transfer process disturbed
5 Water box Sebagai penampung air Corrosion Aging 2 Heat transfer process disturbed
pendingin
Water quality 2 Heat transfer process disturbed
Failure Effect on
No Item Identification Function Failure Mode Failure Cause OCC CRT Component or Functional Next Higher Assembly
Assembly (Equipment)
Water quality 2 Heat transfer process disturbed
Improper maintenance 3
Low Level Sea Water Vacuum priming pump 3
wear out
6 Hotwell structure Konstruksi dari condenser Cracking of welds vibration 2 Defect dissolved oxygen is high
Failure Effect on
No Item Identification Function Failure Mode Failure Cause OCC CRT Component or Functional Next Higher Assembly
Assembly (Equipment)
8 Spray pipes Supply media spray Cracking Vibration 2 N
Manufacturing defect 2 N
9 Water box level indication Faslilitas untuk mengetahui Dirty Environment 6 N Unable to read accurately
(sight glass) kondisi level secara visual
Leakage Aging 5 N
Leakage 6 N
10 Hotwell A Level - Level To detect level of hotwell A Dirty Bad quality of demin water 4 N Unable to read the indicator Unable to detect the level
Gauge (10MAG10CL501) accurately accurately from
10MAG10CL501
11 Hotwell A Level - Level To detect level of hotwell A Dirty Bad quality of demin water 4 N Unable to read the indicator Unable to detect the level
Gauge (10MAG10CL502) accurately accurately from
10MAG10CL502
12 Condenser A Hotwell To detect condenser hotwell Bad wiring and connection Broken, loose, or 4 N Fail to detect hotwell level and Interlock to stop condensate
Level 1 - Differential level dan give interlock signal grounded give LL signal pump when '2/3' logic is met
Pressure Transmitter when the level is LL
(10MAG10CL104)
Bad sensing component of Component failure 4 N Fail to detect hotwell level and Interlock to stop condensate
transmitter give LL signal pump when '2/3' logic is met
Bad sensing lines Valve leakage 4 N Fail to detect hotwell level Interlock to stop condensate
pump when '2/3 LL signal' logic
is met
UNIT BISNIS OPERASI DAN PEMELIHARAAN PLTU BANTEN 1 SURALAYA
Failure Effect on
No Item Identification Function Failure Mode Failure Cause OCC CRT Component or Functional Next Higher Assembly
Assembly (Equipment)
13 Condenser A Hotwell To detect condenser hotwell Bad wiring and connection Broken, loose, or 4 N Fail to detect hotwell level and Interlock to stop condensate
Level 2 - Differential level dan give interlock signal grounded give LL signal pump when '2/3' logic is met
Pressure Transmitter when the level is LL
(10MAG10CL105)
Bad sensing component of Component failure 4 N Fail to detect hotwell level and Interlock to stop condensate
transmitter give LL signal pump when '2/3' logic is met
Bad sensing lines Valve leakage 4 N Fail to detect hotwell level Interlock to stop condensate
pump when '2/3 LL signal' logic
is met
14 Condenser A Hotwell To detect condenser hotwell Bad wiring and connection Broken, loose, or 4 N Fail to detect hotwell level and Interlock to stop condensate
Level 3 - Differential level dan give interlock signal grounded give LL signal pump when '2/3' logic is met
Pressure Transmitter when the level is LL
(10MAG10CL106)
Bad sensing component of Component failure 4 N Fail to detect hotwell level and Interlock to stop condensate
transmitter give LL signal pump when '2/3' logic is met
Bad sensing lines Valve leakage 4 N Fail to detect hotwell level Interlock to stop condensate
pump when '2/3 LL signal' logic
is met
No Reference
1 Title : N-600-16.67/538/538 Type 600 MW Condensing Reheat Steam Turbine
Sub-Title : Control and Protect System Manual
Doc. No. : 71.A158-1E
Man. : Shanghai Electric Power Generation Equipment Co., Ltd. (Shanghai Turbine Works)
2 PM Basis (EPRI)
3 FMEA Workshop UBP Suralaya
UNIT BISNIS OPERASI DAN PEMELIHARAAN PLTU BANTEN 1 SURALAYA
Failure Effect on
No Item Identification Function Failure Mode Failure Cause OCC CRT Component or Functional Next Higher Assembly
Assembly (Equipment)
4 Suralaya Power Plant 600 MW Generating Unit
Profesional Overhaul Regulations for Turbin, CNTIC Consortiom
Finishing Date : 22 Agustus 2011
Workshop Date : 27 Oktober 2011
Revision : 01
Failure Effect on
SEV Failure Detection Method DET RPN Recommended Action PIC
System
Dapat menyebabkan kerusakan 3 Operator check, housekeeping 6 54 Inspeksi SpS. Har. Mekanik
pada boiler tube
3 Maintenance check 6 72 Inspeksi SpS. Har. Mekanik
Loss of Turbine Performance 3 Maintenance check 6 18 Inspeksi SpS. Har. Mekanik
Failure Effect on
SEV Failure Detection Method DET RPN Recommended Action PIC
System
Loss of Condenser Performance 3 Maintenance check 6 54 Eddy Current Test SpS. Har. Mekanik
Failure Effect on
SEV Failure Detection Method DET RPN Recommended Action PIC
System
Possibility of damaging the tubr 3 Maintenance check 6 36 Inspeksi SpS. Har. Mekanik
boiler
Possibility of damaging the tubr 3 Maintenance check 6 36 Inspeksi SpS. Har. Mekanik
boiler
Loss of condenser performance 3 Operator check 6 36 Online monitoring vacuum Operator CR.
Failure Effect on
SEV Failure Detection Method DET RPN Recommended Action PIC
System
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, loop SPS Har K&I
test)
Trip unit when '2/3 LL signal' 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, loop SPS Har K&I
logic is met test)
Finishing Date : 22 Agustus 2011
Workshop Date : 27 Oktober 2011
Revision : 01
Failure Effect on
SEV Failure Detection Method DET RPN Recommended Action PIC
System
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, loop SPS Har K&I
test)
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, loop SPS Har K&I
test)
Trip unit when '2/3 LL signal' 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, loop SPS Har K&I
logic is met test)
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, loop SPS Har K&I
test)
Trip unit when '2/3' logic is met 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, loop SPS Har K&I
test)
Trip unit when '2/3 LL signal' 8 HMI trend check by operator 2 64 Inspection (repaired, calibration, loop SPS Har K&I
logic is met test)
Aditya Timur
Prepared by AMA ENG K&I
Baladika
Failure Effect on
SEV Failure Detection Method DET RPN Recommended Action PIC
System
FAILURE MODE & EFFECT ANALISYS TURBIN UBOH PLTU BANTEN 1 SURALAYA
FMEA Form 1 No. : FMEA-MEC-0002-R00/2011/BSR
Tube Mengalirkan air Bocor 6 Conductivity 7 Life Time 7 294 1. Performace monitoring
pendingin (sea feedwater tinggi
water) Korosi
Unit Derating Erosi
Unit Trip 2. NDE Inspection
3. Waterbox or Hotwell insp
4. Cleaning
5. Patroli Operator
Vacuum Pump Membuat dan Vacuum Low 3 Pressure LP exhaust 6 Vacuum Pump tidak 7 126 1. Performance monitoring
mempertahankan tinggi beroperasi maksimal
kondisi vacuum 2. Menurunkan beban
pada condenser Unit Derating Level Air laut turun 3. Patroli Operator
Unit Trip Kebocoran pada
Condensor
Ball Cleaning Membersihkan tube Bola taproge hilang 3 Tube condenser 7 Ball Cacther yang tidak full 6 126 1. Pemeriksaan line saat star
condenser kurang bersih close ball cleaning
Tube condenser Ukuran bola taproge yang 2. Continuos injection chlori
tersumbat tidak sesuai
Banyak tritip yang
berkembang
Name Position
Prepared by Danny Yunarta AMA ENG. Boiler &
Aux.
Reviewed by Erik Pujianto SPS. Reliability
Task Recommended
PIC
Action(s)