LEGEND:

LIGHTING SCEDULE

SIZE: 1274mm X 195mm X 116mm


BRAND: FUMACO
MODEL: ZUMTOBEL FT-236
FIXTURE COLOR: WHITE
LAMP/BULB: 2X36 WATTS IP65 FLUROSCENT LAMP
LAMP COLOR: DAYLIGHT

SQAURE LIGHT WITH LED LIGHT WARM WHITE

DOWNLIGHT W/LED LIGHT DAYLIGHT

SURFACE MOUNTED (DAYLIGHT) CFL

311X120X110mm FUMACO MINNIE MR 203L, WHITE WITH 2X10 WATTS LED LAMP, DAYLIGHT

CEILING FINISH & TYPE

[CF – 1] 6mm THK FICEM BOARD PAINTED FINISH ON STANDARD METAL FURRYING ASSEMBLY.

[FF – 2] 10mm THK GYPSUM BOARD ON STANDARD METAL FURRING ASSEMBLY.

[EBS] EXPOSED SLAB SOFFIT.

WALL FINISH & TYPES

[WF – 1] FOR ALL EXTERIOR WALL PARTITION USE 6’’ CHB WALL WITH 20MM THK. PASTER
BOTHSIDES PAINTED SEMI GLOSS FINISH BY BOYSEN ACRYTEX (EXTERIOR WALL) PAINT FINISH BY
BOYSEN ACRYTEX SEMI GLOSS LATEX PAINT, 20mm THK. PLASTER IN 6’’ CONCRETE HOLLOW
BLOCKS.

[WF - 2] FOR ALL INTERIOR WALL PARTITION USE 4’’ CHB WALL WITH 20mm THK, PLASTER
BOTHSIDE PAINTED SEMI GLOSS FINISH BY BOYSEN PERMACOAT (INETERIOR WALL) PAINT FINISH
BY BOYSEN PARMACOAR SEMI GLOSS LATEX PAINT,20mm THK. PLASTER BITH SIDE IN 4’’ CONRETE
HOLLOW BLOCKS .

1.0 GENERAL NOTES:

1.1 ALL DIMENSIONS ARE SHOWN IN MILLIMETERS, ELEVATION ARE IN METERS UNLESS
NOTED OTHERWISE

1.2 THE CONTRACTOR SHALL VERIFY ALL DIMENSION AD CONDITION AT THE SITE, AND
SHALL NOTIFY THE INGINEER OF DISCREPAMCIES BETWEEN ACTUAL CONDITION AND
INFORMATION WHONW ON THE DEAWINGS BEFORE PROCEEDING WITH WORK. THIS
SHALL INCUDES LOCATION AND DIMENSION OF THE GROOVES, REFLETS, SLEEVES,
CURBS, OPENING, EMBEDDED OR ATTACHED IEMS, ETC. REFER TO ATCHECTECTURAL,
MECHANICAL ELECTRICAL AND PLUMBING ALL FIGURE DIMENSTION SHALL TAKE
PRECEDENCE OVER SCALE SHOWN ON PLANS, DRAWING.
1.3 SECTION OR DETAIL. SPECIFIC NOTES AND DETAIL ON DRAWINGS AND SHALL TAKE
PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS.

1.4 THE CONTRACT STRUCTURAL DRAWING AND SPECIFICATION REPRESENT THE FINISHED
STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUTION UNLESS SO
STATED. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MEASURE TO PRETECT THE
STRUCTURE, ADJACCEMNT PROPERTIES, WORKMEN AND OTHER PERSON DURING ALL
PHASES OF CONTRUCTION.

1.5 THE CONTRACTOR SHALL IMMEDIATELY NOTIGY THE OWNER AND/OR THE ENGINEER
OF ANY CONDITION WHICH IN HIS OPINIION MIGHT ENDANGER THE STABILITY OF THE
STRUCTURE OR CAUSE DISTRESS IN THE STRUCTURES.

1.6 CONSTRUCTION MATERIALSHALL NOT BE STORED ON POURED FLOOR. IT IS THE


GENERAL CONSTRACTOR’S RESPONSIBILITY TO ENSURE THAT THE SUB-CONSTRACTOR
ARE INFORMED AND DO NOT VIOLATE THIS IMPORTANT REQUIREMENT.

1.7 THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACINGS AND SHORING
FOR ALL THE STRUCTURAL MEMBERS AS REQUIRED FOR STRUCTURE STABILITY DURING
ALL PHASES OF CONTRUCTION.

1.8 THE CONTRACTOR SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE PROPER
ALIGHNMENT OF THE STRUCTURE DURING AND AFTER THE INSTALLATION OF ALL
STRUCTURAL AND FINISH MATERIALS JOB UNLESS OTHERWISE SHOWN ON THE
DRAWINGS.

2.0 MATERIALS
2.1 NORMAL WEIGHT CONRETE:
2.2 CONRETE USED IN THIS WORK SHALL HAVE A MINIMUM COMPRESS STRENGTH
©28 DAYS AS FOLLOWS

SLAB ON GRADE fc’=20.7MPa(3,000 PSI)


FOOTING fc’=27.6MPa(5,000 PSI)
COLUMNS/ SHEAR WALLS fc’=34.5MPa(5,000 PSI)
GIRDERS/BEAM, SLAB, STRAIRS fc’=27.6MPa(4,000 PSI)

2.1.2 MINIMU CONCRETE COVER FOR REINFORCING BARS SHALL BE AS FOLLOWS

A. FOOTING & BOT, OF FOORING TIE BEAM = 75mm (CAST AGAINST EARTH).
B. SIDES OF FOOTING TIE BEAM = 50mm (CAST AGAINST FORMS).
C. BEAMS, COLUMNS & SHEAR WALL = 40mm (TO STIRUPS AND TIES).
D. SLABS AND WALL = 20mm (CAST AGAINST FORMS).

2.3 REINFORCING BARS:


2.2.1 UNLESS OTHERWISE SPECIFIED ON PLANS, ALL REINFORCING BARS SHALL BE
DEFORMED WITH A MINIMUM YIELD STRENGTH, fy’=414MPa(6,000 PSI) FOR Ø12 AND
ABOVE AND fy’=275MPa(4,000 PSI) FOR Ø10 BELOW.
2.2.2 UNLESS SHOWN OTHERWISE ON PLANS, SPLICES SHALL BE AS FOLLOWS:
A. BEAMS AND FOOTING TIES BEAMS: TOP AND BOTTOM BARS SHALL NOT BE SPILED
WITHIN THE COLUMN OR WITHIN A DISTANCE OF TWICE THE MEMBER FEPTH FROM
THE FACE OF THE COLUMN; AT LEASTTWO EXTRA STIRRUP – TIES SHALL BE
PROVIDED AT ALL SPLICES.
B. COLUMNS: SPLICES WHEN PERMITTED SHALL BE MADE WITHIN THE CENTER HALF
OF THE COLUMN HEIGHT, AND LAP SPLICE SHALL NOT BE LESS THAN 40 BAR
DIAMETERS. THE USE OF APPROVED MECHANICAL DEVICES MAY BE PERMITTER
PROVIDED THAT NOT MORE THAN LERNATE BARS ARE SPLICED AT ANY LEVEL AND
THE MINIMUM VERTICAL DISTANCE BETWEEN TWO ADJACENT BAR SPLICES SHALL
BE 600mm.
C. CMU WALL: VERTICAL BARS SHALL BE SPLICED AT THE TOP OF WALL FOOTING OR
TIE BEAM AND AT THE BOTOOM OF RC LINTEL BEAM OR BEAMS; SPLICE LENGHT
SHALL BE 600mm MIN.

2.2.3 UNLESS INDICATED OTHERWISE ALL BEAMS TERMINATING AT THE COLUMN SHALL HAVE TOP
AND BOTTOM BARS EXTENDING TO THE FAR FACE OF THE COLUMN, TERMINATING IN A STANDARD
90® HOOK LENGHT OF ANCHORAGE NOT LESS THAN 600mm.

2.3 CONRETE MASONTY UNITS (CMU)

2.3.1 CMU USED IN THESE WORKS SHALL HAVE A MINIMUM ULTIMATE COMPRESSIVE STRENGTH
@28 DAYS FOLLOWS:
100 mm THICK NON-LOAD BEARING CMU, f’m = 2.4MPa (350PSI)
150mm THICK NON-LOAD BEARING CMU, f’m = 2.4MPa (350PSI)
2.3.2 ALL CELLS SHALL BE SOLIDLY FILLED WITH GROUT. CONCRETE SHALL HAVE A MINIMUM
COMPRESSIVE STREGTH OF 13.80MPa (2000PSI) @600.
2.3.3 UNLESS INDICATED OTHERWISE, CMU REINFORCEMENT SHALL BE 100mmØ HOR. BARS
@600 AND 10mm VERT. BARS @600.

2.4 STRUCTURAL STEEL/ ANCHOR BOLTS/BOLTS/WELDS & WELMENTS :

2.4.1 ALL STRUCTURAL STREEL SHALL HAVE A MINIMUM YIELD STRENGTH, fy=248MPa (kSI) AND
SHALL CONFORM ASTM A 36 SPECIFICATION.
2.4.2 ALL STRUCTURAL STRELL SHALL BE FAVICATED AND ERECTED IN ACCORDANCE WITH THE
AISC SPECIFICATION (9TH EDITION) AND CODE OF STANDARD PRACTICE AS AMENDED TO
DATE.
2.4.3 ALL COLD FORMED STELL SHALL HAVE MINIMUM STRENGTH fy=230 MPa(33KSI).
2.4.4 NO STEEL SHALL BE FABRICATED OR ERECTED UNTIL SHOW DRAWINGS HAVE BEEN
APPROVED BY THE STRUCTURAL ENGINEER.
2.4.5 ALL SHOP AND FILED WELDING SHALL BE IN ACCORDANCE WITH AWS D.1.1-2000 AND
PERFORMED BY QUALIFIED WELDERS.
2.4.6 UNLESS INDICATED OTHERSWISE, WELDING ELECTRODES SHALL BE E70XX, MINIMUM
THICKNESS OF WELD SHALL BE 3mm.
2.4.7 UNLESS OTHERWISE INDICATED ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A307
SPECICFICATIONS.
2.4.8 BOLTS FOR MEMBERS CONNECTION SHALL BE HIGH STREGTH BOLTS, CONFORMING TO
ASTM A325 FRICTION TYPE WITH WASHERS.
3.0 CONSTRUCTION JOINTS:

3.1 CONTRUCTION JOINTS NOT INDICATED ON PLANTS SHALL BE MADES SO AS TO EAST


IMPAIR THE STRENGTH OF THE STRUCTURE AND SHALL BE SUBJECT TO APPROVAL OF
THE ENGINEER.
3.2 UNLESS SHOWN OTHERWISE, SLAB ON GRADE SHALL HAVE CONTROL JOINTS @6.00mm
MAXIMUM CENTER TO CENTER.

4.0 FOUNDATIONS:

4.1 FOOTINGS WERE DESIGNED USING AN ALLOWABLE SOIL BEARING CAPACITY OF 250KPA
AT DEPTHS INDICATED IN THEDRAWING. CONFIRMATION OF ACTUAL SOIL BEARING
CAPACITY SHALL BE DONE PRIOR TO CONSTRUCTION OF FOUNDATION SUCH
CONFIRMATION SHALL BE PUT IN WRITING AND SUBMITED TO THE ENGINEER FOR
APPROVAL, INCREASE IN FOUNDATION SIZE SHALL BE DONE WHEN ACTUAL SOIL
BEARING CAPACITY, CONFIRMED DURING EXCAVATION, WARRANT REVISION OF
FOUNDATION SIZES.
4.2 WHERE LOOSE/SOFT MATERIAL IS ENCOUNTERED AT DEPTH OF FOOTING/FOUND
INDICATED, EXCAVATE TO FIRM LAYER AND REPLACE LOOSE/SOFT MATERIALS
UNDERNEATH THE FOOTING WITHIN THE FOOTING AREA PLUS 1/2 DEPTH OF SOILD
MATERIAL ON ALL SIDES WITH SELECTED BACKFILL. COMPACT SELECTED BACKFILL TO
95% MAXIMUM DRY DENSITY (ASTM D1557).
4.3 ALL COLUMN FOOTING SHALL REST ON 100mm THK COMPACTED GRAVEL BASE
COURSE, UNLESS OTHERWISE STATED.
4.4 FILL/BACKFILL SHALL BE PLACED IN 200mm LAYERS AND EACH LAYER SHALL BE
COMPACTED TO 95% MAXIMUM DRY DENSITY SUBSEQUENT LAYERS ARE TO BE LAID.

TABLE: LAP SPLICE & ANCHORAGE LENGTH

BAR ANCHORAGE STANDARD HOOK LAP SPLICE (m) UNIT MIN. LAP SPLICE
DIAMETER LENTH (m) WEIGHT LENGHT OF COL
(mm) (m) TENSION BAR COMP.BAR (KG/m) REING INDIVIDUAL
BARS
90* 180* 135* TOP OTHERS TOP OTHERS W/TIES W/SPLICE
BAR BAR
10 0.50 0.15 0.13 0.10 0.42 0.30 0.42 0.30 0.616 0.30 0.30

12 0.50 0.20 0.15 0.12 0.42 0.30 0.42 0.30 0.886 0.30 0.30

16 0.60 0.25 0.18 0.14 0.73 0.52 0.87 0.62 1.576 0.52 0.47

20 0.60 0.30 0.20 0.20 0.91 0.65 1.10 0.78 2.463 0.65 0.56

25 0.68 0.40 0.28 0.26 1.15 0.82 1.40 1.00 3.851 0.80 0.73

28 0.86 0.48 0.38 -- 1.45 1.03 1.53 1.09 4.831 0.90 0.83

32 1.12 0.56 0.43 -- 2.40 1.70 2.00 1.24 6.306 1.03 0.93
36 1.43 0.61 0.48 -- 2.40 1.70 2.00 1.40 7.983 1.20 1.05

NOTES
1. ACI SECTION 12.4 STATES THAT DEVELOPMENT LENGHT ON INDIVIDUAL BARS/IN A BUNDLE
IN TENSION OR COMPRESSION SHALL BE THAT FOR THE INDIVIDUAL BAR, INCREASED 20%
FOR THREE BAR BUNDLE AND 33% FOR FOUR BAR BUNDLE.
2. FOR COLUMNS AT ANY LEVEL NO MORE THAN ALRENATIVE BAR SHOULD BE SPLICED NOT
MORE THAN 33% OF THE BARS SHALL BE SPLICED W/IN THE REQUIRED LAP LENGTH
MINIMUM DISTANCE BETWEEN TWO ADJACENT BARS SLIDES SHALL BE 600mm.
3. TOP BARS ARE HORIZONTAL BARS W/MORE THAN 300mm DEPTH OF CONCRETE CAST
BELOW THAT REINFORCEMENT.
4. AS MUCH AS POSSIBLE SPLICE SUBJECTED TO TENSILE STRESSES ARE DISCOURAGE THERE
SOULD BE AVOIDED OR PROVIDED W/STANDARD HOOKS.

MARK DESCRIPTION
BP1 25MM THK BASEPLATE
BT1 Ø20mm/Ø25mm HIGH
STRENTH ANCHOR A325 BOLT
W/500mm EMBEDMENT
SP1 100X150X12mm THK
STIFFENER PLATE
ST1 STEEL COLUMN (SEE PLAN &
SCHED)
G1 25mm THK HIGH STRENGTH
NON-SHRINK GROUT
PC CONCRETE PEDESTAL (SEE
PLAN & DETAIL)
S1 SLAB ON GRADE
TS1 COLUMN TIES

GENERALS NOTES(CE)
1. CONRETE STRENGH f’c = 4000PSI
2. REINFORCEMENT fy = 40000Ø10 &SMALLER fy= 60000Ø12&LARGER.
3. SUPPORTING BEAM (SEE PLAN) INFORM ENGINEERING RECORD IF SUPPORTING
BEAM/WALL IS NOT PROVIDED.
4. FOR PRE-CAST DESIGN USE SAME SLAB THINKNESS & SCHEDULE REINFORCEMENT. SUBMIT
SHOP DRAWING FOR ENGINEER APPROVAL.
5. COORDINATE ARCHITECTURAL PLANS FOR LENGTH, WIDTH, ETC & OTHER STAIR
INFORMATION PRIOR TO POURING OF CONRETE.

GENERAL NOTES (EE)


1. ALL ELECTRICAL INSTALLATION HEREIN SHALL BE IN ACCORADANCE WITH THE PROVISION
OF THE LATEST OF THE PHILIPPINES ELECTRICAL CODES THE RULE REGULATION AND
REQUIREMENT OF THE LOCAL COMPANY AND THE LAWS AND ORDINANCES OF THE LOCAL
ENFORCING AUTHORITY.
2. THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE 230v, 1dia, 2W, 60 CYCLES.
3. THE CONTRACTOR SHALL VERIFT AND ORIENT THE ACTUAL LOCATION OF SERVICE
ENTRANCE FOR CONNECTION TO POWER SUPPLT OF THE PROJECT.
4. ALL CONDUCTORS SHALL BE COPPER TYPE THW.75* 600VOLTS INSULATION MINIMIZE SIZE
SHALL BE 3.5mm? UNLESS OTHERWISE SPECIFIED.
5. ALL MATERIALS SHALL BE NEW AND OF THE APPROVED TYPE FOR THE LOCATION
INTENDED.
6. ALL 20AMPERE CIRCUIT HOMERUNS TO PANELBOARD MORE THAN 30.5M (100FT) IN
LENGTH SHALL BE 5.5mm? UNLESS OTHERWISE SPECIFIED.
7. STANDARD TYPE OF ACCESSORIES SPICING DEVICES TERMINATION AND OTHER
APPURTENANCE FOR THE ENTIRE ELECTRICAL INSTALLATION SHALL BE USED.
8. FOR ACTUAL LOCATION OF LIGHT FICTURE MOTORS, FANS AND OTHER ELECTRICAL
EQUIPMENT, SEE ARCHITECTURAL, MECHANICAL PROCTECTION AND SANITARY DRAWINGS.
9. ALL NON-CURRENT CARRYING METALS PARTS OF ELECTRICAL EQUIPMENT AND LIGHTING
FIXTURE SHALL EFFECTIVELY GROUNDED.
10. CONDUITS AND OTHERS WIRE ROUTING SHOWN ARE ONLY REPRESENTATION THE
CONTRACTOR SHALL SUBMIT SHOP DRAWING ON ALL PROPOSED ROUTING ( SHOWN OR
EVEN NOT SHOWN IN THE PLAN) AND INSTALLATION FOR APPROVAL.
11. ALL CIRCUIT BREAKER SHALL BOLT-ON TYPE WITH 10KIAC MINIMUM OR INDICATED.
12. WHEREVER REQUIRED AND NECESSARY, PULL BOXES AND JUNCTION BOXES OF PROPER
SIZE SHALL BE INSTALLED AT CONVENIENT AND INCONSPICUOUS LOCATION ALTHOUGH
SUCH BOXES ARE NOT SHOWN IN THE PLANS NOR MENTIONED IN THE SPECIFICATION.
13. ALL SERVICE ENTRANCE EQUIPMENT SUCH AS PANEL BOARD (SAFETY SWITCH OR CIRCUIT
BREAKER) TYPE SHALL BE PROPERLY GROUNDED IN ACCORFANCE WITH THE REQUIREMENT
OF THE PHILIPPINES ELECTRICAL CODE.
14. ALL WALL OUTLET SHALL BE INSTALLED AT THE FOLLOWING HEIGHTS ABOVE THE FINISHED
FLOOR LEVEL UNLESS OTHERWISE NOTE.
A. WALL SWITCHED--------------------------------------1.20M
B. CONVENIENCE OUTLETS----------------------------0.30M
C. WALL LIGHT OUTLETS-------------------------------2.70M ABOVE FINISHED FLOOR
15. ALL ELECTICAL WORKS SHALL BE DONE IN A WORKMANLIKE MANNER WITH A SKILLED
MANPOWER SUPERVISED BY A DULY LICENSED ELECTRICAL ENGINEER.

GENERAL NOTES (CE)


 ALL SOILD PIPE AND WASTE PIPE LINE SHALL BE PVC PIPE AND SHALL BE PROPERLY JOINTED
WITH PVC SOLVENT CEMENT.
 WASTE PIPE SHALL BE 100MMDIA, PVC PIPE FPR MAIN PIPE MAIN AND 59MMDIA PVC PIPE
FOR LAVATORY, FLOOR DRAIN MAIN VENT 50MMDIA AND BRANCH VENT 50MMDIA.
 WATER SUPPLY LINES SHALL BE PPR PIPE AND PROVIDE INDIVIDUAL SHUT-OFF VLAVE FOR
EVERY BRANCH FIXTURE.
 VENT STOCK THRU ROOF SHALL BE EXTENDED AT 0.30M ABOVE THE ROOFLINE .
 WATER LINES FROM SOURCE SHALL BE 25MMDIA, PVC AND 20mmDIA PVC FOR BUILDING
CONNETION..
 THE SLOPE OF HOUSE AND SEWER LINE DRAIN SHALL BE 2% TO THE DIRECTION OF FLOW
 SEPTIC VAULT SHALL BE CONSTRUCTED WATERLIGHT/WATERPROOF TO ELIMINATE
SEEPAGE.
 OVERFLOW FROM SV SHALL BE DISCHARGED DIRECTLY TO STREET RAINAGE. DRAIN PIPE
AND CATCH BASINS DISCHARGING OUTFLOW FROM THE SEPTICS VAULT SHALL ALSO BE
CONSTRUCTED WATERLIGHT/WATERPROOF TO PREVENT LEAKAGE TO PERCOLATE TO THE
GROUND.
 AS STATE ON PD1096 OTHERWISE KNOWN AS THE BUILDING CODE OF THE PHILIPPINES
SECTION 902, WATER SUPPY SYSTEM (a)WHENEVER AVAILABLE THE POTABLE WATER
REQUIRMENTS FOR BUILDING USED FOR HUMAN HABITATION SHALL BE SUPPLIED FROM
EXISTING MUNICIPAL OR CITY WATER WORKS SYSTEM.
 ALL OTHER REQUIREMENT SHOULD FOLLOW THE PROVISION OF THE NATIONAL PLUMBING
CODE OF THE PHILIPPINES AND R.A 1378.
 PLUMBING WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DUSY LICENSED
MASTER PLUMBER.