0226419
*
* BH5928 approved
ET Canada / USA BI 5928 pending
Applications
Protection of people and machines
· Emergency stop circuits on machines
· Monitoring of safety gates
· Stop category 1 can be realised
Indication
Notes
To select automatic restart terminals 13 - 14 must be bridged. Open A line fault across the On-button which occurred after activation of the
terminals 13 - 14 select manual restart, the On-button must then be relay, will be detected with the next activation and the output contacts will
connected to S33 - S34. not close. If a line fault occurs after the voltage has been connected to
Line fault detection on On-button: S12, S31, S32, the unit will be activated because this line fault is similar
The line fault detection is only active when S12 and S22 are switched to the normal On-function.
simultaneously. If the On-button is closed before S12, S31, S32 is The unit can be operated with single channel and 2-channel operation
connected to voltage (also when line fault across On-button), the output with cross fault monitoring. For connection please refer to application
contacts will not close. examples.
Block diagram
A1 A2
(+) (-) S11(+) S12 S31 S13 S22 S32 S33 S14 S34 Y39 Y40 13 23 31 47 57 67
K1 K1t
Overvoltage and Timer
short circuit prot. Monitoring logic release delay
K2 K2t
24V K1 K2 K1t K2t
S21(-) 14 24 32 48 58 68
M7072_c
All technical data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time. 1 BH 5928, BI 5928 / 12.07.02 d
Circuit diagrams
A1
13 23 33 41 57 (+) 13 23 37 47
A1 S11 S11
S31 S32 S12 S13 S14 S31 S32 S12 S13 S14
(+) (+)
(+)
A1(+) S11 13 23 37 47
A1(+) S11 13 23 33 41 57
S12
S12 S13
S13 S14 K1
S14 K1
S22 K1t
S22 K1t S31
S31 S32
S32 S33
S34 K2
S33
S34 K2 Y39 K2t
Y40
Y39 K2t
Y40
A2(-) S21 14 24 38 48
BH 5928.47 BH 5928.91
13 23 31 47 57 67 13 23 33 47 57 67
A1 S11 A1 S11
(+) S31 S32 S12 S13 S14 S31 S32 S12 S13 S14
(+) (+) (+)
S21 A2 S21 A2
Y39 Y40 (-) S22 S33 S34 (-) Y39 Y40 (-) S22 S33 S34
M7278_c (-) M7279_c
14 24 32 48 58 68 14 24 34 48 58 68
BH 5928.92 BH 5928.93
2
Circuit diagrams
13 23 33 41 57
S11
A1 A2 S31 S32 S12 S13 S14
(+)
A1 S11 13 23 33 41 57
S12
S13
S14 K1
S22 K1t
S31
S32
S33
S34 K2
Y39 K2t
Y40
A2 S21 14 24 34 42 58
S21
Y39 Y40 (-) S22 S33 S34
M8081_a
14 24 34 42 58
BI 5928.47
13 23 31 47 57 67 13 23 33 47 57 67
S11 S11
A1 A2 S31 S32 S12 S13 S14 A1 A2 S31 S32 S12 S13 S14
(+) (+)
A1 S11 13 23 31 47 57 67 A1 S11 13 23 33 47 57 67
S12 S12
S13 S13
S14 K1 K1
S14
S22 K1t S22 K1t
S31 S31
S32 S32
S33 S33
S34 K2 K2
S34
Y39 K2t Y39 K2t
Y40 Y40
A2 S21 14 24 32 48 58 68 A2 S21 14 24 34 48 58 68
S21 S21
Y39 Y40 (-) S22 S33 S34 Y39 Y40 (-) S22 S33 S34
M8080_a M8079_a
14 24 32 48 58 68 14 24 34 48 58 68
BI 5928.92 BI 5928.93
The gold plated contacts of the BH 5928 mean that this module is also Input
suitable for switching small loads of 1 mVA - 7 VA, 1 mW - 7 W in the range
0,1 - 60 V, 1 - 300 mA. The contacts also permit the maximum switching Nominal voltage U N:
current. However since the gold plating will be burnt off at this current BH 5928: DC 24 V, AC/DC 24 V
level, the device is no longer suitable for switching small loads after this. BI 5928: AC 110 V, 230 V
The terminal S21 permits the operation of the device in IT-systems with Voltage range: AC
insulation monitoring, serves as a reference point for testing the control 0,85 ... 1,1 UN
voltage and is used to connect the E-stop loop when cross fault monitoring DC AC/DC
is selected. at 10% residual ripple: 0,9 ... 1,1 U N 0,95 ... 1,1 UN
Connecting the terminal S21 to the protective ground bridges the internal at 48% residual ripple: 0,8 ... 1,1 U N 0,8 ... 1,1 UN
short-circuit protection of Line A2(-). The short-circuit protection of line Nominal consumption: AC approx. 6,0 VA
A1(+) remains active. DC approx. 3,5 W
Y39 - Y40 must be closed to have timed outputs. By opening the bridge Nominal frequency: 50 / 60 Hz
between Y39 and Y40 the time delay can be interrupted immediately. Min. Off-time: 1s
Without bridge the contacts switch without delay. Control voltage on S11: DC 23 V at UN
The time setting has to be sealed by the user after test. Control current over
S12, S32: 40 mA at UN each
Min. voltage on
S12, S32: DC 21 V when relay activated
Short-circuit protection: Internal PTC
Overvoltage protection: Internal VDR
3
Technical data Technical data
4
Characteristics
M 7073_a
250
200
Switching voltage U [ V]
150
100
50
0
1 2 3 4 5 6 7 8
Switching current I [A]
Application examples
L1 L1
(+) (+)
Off E-stop
On K4
On E-stop
K5
S32 13 .. .. A1(+) S11 S33 S34 S31 S32 13 23 ..
A1(+) S11 S33 S34 S12 S31
N
(-) M7074_a
K4 K5
N
Single channel emergency stop circuit. This circuit does not have any M7077_a
(-)
redundancy in the emergency-stop control circuit
Contact reinforcement by external contactors, 2-channel controlled. The
output contacts can be reinforced by external contactors with positive
guided contacts for switching currents > 5 A.
Functioning of the external contactors is monitored by looping the NC
contacts into the closing circuit (terminals S13-S14 or S33-S34)
L1 L1
(+) (+)
E-stop E-
stop
S1 On
A1(+) S11 S13 S14 S31 S32 Y39 Y40 13 .. .. A1(+) S31 S33 S34 S32 S22 S21 13 .. ..
.. .. .. ..
A2(-) S21 S22 14 A2(-) S11 S12 Y39 Y40 14
N
(-) M7078_a
N
(-) M7075_a
2-channel emergency stop circuit with cross fault detection
2-channel emergency stop circuit without cross fault monitoring autostart
and interruption of time by S1
5
Application examples
L1 L1
(+) (+)
Sliding guard closed
E-stop
On K4
S1
K5
A1(+) S11 S33 S34 S31 S32 13 .. .. On
S2
BH5928, BI5928
A1(+) S11 S33 S34 S12 S32 13 .. ..
E. DOLD & SÖHNE KG • D-78114 Furtwangen • Postf. 1251 • Tel. +49 7723 654 0 • Telefax +49 7723 654 356
e-mail dold-relays@t-online.de • internet http://www.dold.com
6