DSEGenset

DSE7310/20 ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY

AUTO START & AUTO MAINS FAILURE BS EN 61000-6-2


EMC Generic Immunity Standard for
the Industrial Environment
CONTROL MODULES BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
FEATURES ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment

The DSE7310 is an Auto Start The DSE7320 will also monitor the The extensive list of features includes TEMPERATURE
Control Module and the DSE7320 is mains (utility) supply. The modules enhanced event and performance BS EN 60068-2-1
o
Ab/Ae Cold Test -30 C
an Auto Mains (Utility) Failure Control include USB, RS232 and RS485 monitoring, remote communications BS EN 60068-2-2
Module suitable for a wide variety of ports as well as dedicated DSENet® and dual mutual standby (DSE7310 Bb/Be Dry Heat +70 oC
single, diesel or gas, terminals for system expansion. only) to reduce engine wear. VIBRATION
gen-set applications. BS EN 60068-2-6
Both modules are compatible with The modules can be easily Ten sweeps in each of three
major axes
Monitoring an extensive number of electronic (CAN) and non-electronic configured using the DSE 5 Hz to 8 Hz @ +/-7.5 mm,
engine parameters, the modules will (magnetic pick-up/alternator sensing) Configuration Suite PC software. 8 Hz to 500 Hz @ 2 gn
display warnings, shutdown and engines and offer an extensive Selected front panel editing is also HUMIDITY
engine status information on the number of flexible inputs, outputs available. BS EN 60068-2-30
back-lit LCD screen, illuminated and extensive engine protections so Db Damp Heat Cyclic 20/55 oC
@ 95% RH 48 Hours
LEDs, remote PC and via SMS text the system can be easily adapted to BS EN 60068-2-78
alerts (with external modem). meet the most demanding industry Cab Damp Heat Static 40 oC
@ 93% RH 48 Hours
requirements.
SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes
15 gn in 11 mS

DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
COMPREHENSIVE FEATURE LIST TO SUIT A control panel with the supplied sealing gasket.

WIDE VARIETY OF GEN-SET APPLICATIONS


MODEM MODBUS PC
DSE2130
DSE2157
DSE2548 8 4 4
DSE2510/20
232 485

DSENET® RS232 AND USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER


EXPANSION RS485 PORT INPUTS SENDERS STOP SUPPLY 8-35V

DEUTZ
DSE7310/20 ISUZU
PERKINS
CATERPILLAR
7 MTU
VOLVO
OTHER
CUMMINS
SCANIA

MAINS (UTILITY) N/C VOLT FREE N/O VOLT GENERATOR SENSING CHARGE FUEL & CRANK ELECTRONIC
SENSING OUTPUT FREE OUTPUT ALTERNATOR OUTPUTS ENGINES &
DSE7320 ONLY (Flexible with CAN) MAGNETIC PICK-UP

VOLTS CURRENT VOLTS


D+
W/L +

1ph 1 1 1ph 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N E N
N

ISSUE 6

CALL US TODAY REQUEST A QUOTE SHOP ONLINE


1-888-POWER-58 parts@genpowerusa.com www.genpowerusa.com
®

DSEGenset

DSE7310/20 SPECIFICATION

DC SUPPLY

AUTO START & AUTO MAINS FAILURE CONTINUOUS VOLTAGE RATING


8 V to 35 V Continuous

CONTROL MODULES CRANKING DROPOUTS


Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
FEATURES supply recovers to 5 V. This is achieved
DSE7320 without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.

DSE7310 MAXIMUM OPERATING CURRENT


340 mA at 12 V, 160 mA at 24 V

MAXIMUM STANDBY CURRENT


160 mA at 12 V, 80 mA at 24 V

CHARGE FAIL/EXCITATION RANGE


0 V to 35 V

MAINS (UTILITY) DSE7320 ONLY


VOLTAGE RANGE
15 V - 333 V AC (L-N)

FREQUENCY RANGE
3.5 Hz to 75 Hz

KEY FEATURES • kW overload protection • DSENet® expansion compatible OUTPUTS


• 4-Line back-lit LCD text display • Reverse power protection • Integral PLC editor OUTPUT A (FUEL)
15 A DC at supply voltage
• Five key menu navigation • Power monitoring (kW h, kV Ar,
• Front panel editing with PIN kV A h, kV Ar h) KEY BENEFITS OUTPUT B (START)
protection • Load switching (load shedding • 132 x 64 pixel ratio display for 15 A DC at supply voltage

• LED and LCD alarm indication and dummy load outputs) clarity OUTPUTS C & D
• Customisable status screens • Automatic load transfer (DSE7320) • Real-time clock provides 8 A 250 V (Volt free)
• Power save mode • Unbalanced load protection accurate event logging
AUXILIARY OUTPUTS E,F,G,H
• Support for up to three remote • Independent Earth Fault trip • Multiple date and time scheduler 2 A DC at supply voltage
display units • True dual mutual standby with • Set maintenance periods can be
• 9 configurable inputs load balancing timer (DSE7310 configured to maintain optimum GENERATOR
VOLTAGE RANGE
• 8 configurable outputs only) engine performance 15 V - 333 V AC (L-N)
• Flexible sender inputs • USB connectivity • Ethernet communications (via
• Configurable timers and alarms • Backed up real time clock DSE860/865 modules), provides FREQUENCY RANGE
3.5 Hz to 75 Hz
• 3 configurable maintenance • Fully configurable via DSE advanced remote monitoring at
alarms Configuration Suite PC software low cost MAGNETIC PICK UP
• Multiple date and time scheduler • Configurable display languages • Modules can be integrated into VOLTAGE RANGE
+/- 0.5 V to 70 V
• Configurable event log (250) • Remote SCADA monitoring via building management systems
• Control logic facilities DSE Configuration Suite PC (BMS) FREQUENCY RANGE
• Easy access diagnostic page software • Increased input and output 10,000 Hz (max)

• CAN and Magnetic Pick-up/Alt. • User selectable RS232 and expansion capability via DSENet® DIMENSIONS
sensing RS485 communications • Licence-free PC software OVERALL
• Fuel usage monitor and low fuel • Configurable Gencomm pages • IP65 rating (with supplied gasket) 240 mm x 181 mm x 42 mm
9.4” x 7.1” x 1.6”
alarms • Advanced SMS messaging offers increased resistance to
• Charge alternator failure alarm (additional external modem water ingress PANEL CUT-OUT
• Manual speed control (on required) • PLC editor allows user 220 mm x 160 mm
8.7” x 6.3”
compatible CAN engines) • Start & stop capability via SMS configurable functions to meet
• Manual fuel pump control messaging specific application requirements MAXIMUM PANEL THICKNESS
• Engine exerciser • Additional display screens to help 8 mm
0.3”
• “Protections disabled” feature with modem diagnostics

RELATED MATERIALS
TITLE PART NO’S
DSE7310 Installation Instructions 053-028
DSE7320 Installation Instructions 053-029
DSE7200/7300 Quick Start Guide 057-101
DSE7200/7300 Operator Manual 057-074
DSE7200/7300 Configuration Suite PC Manual 057-077

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-051/10/11 (8) US
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457

CALL US TODAY REQUEST A QUOTE SHOP ONLINE


1-888-POWER-58 parts@genpowerusa.com www.genpowerusa.com

Das könnte Ihnen auch gefallen