Beruflich Dokumente
Kultur Dokumente
Electrical, Multifunction,
and mA Loop Calibration
Temperature Calibration
Process Calibration Tools
From Fluke and Fluke Calibration
Finding the right tools for the specific challenges you face every day is important, so
we’ve provided an “at-a-glance” guide to the wide range of multifunction, mA loop,
pressure and temperature calibrators that we carry. For complete information on
our field and bench solutions to all your calibration needs visit www.fluke.com,
www.flukecal.com, or one of the product pages listed in this catalog.
mA loop calibration
Loop calibrators are essential tools for working with 4-20 mA current loops. Fluke loop
calibrators provide mA sourcing, simulation and measurement, readouts in both mA
and % of span, 24 V loop supply, simple operation and accuracy you can count on.
Temperature calibration
Temperature calibration refers to the calibration of any device used in a system that
measures temperature—from sensors to transmitters to displays. Fluke offers bench and
field solutions to ensure process temperature accuracy of not only the system’s electronic
temperature signals, but also the very temperature sensors that initiate those signals.
Electrical,
Pressure and Temperature
Multifunction, and
Flow Calibration Calibration
mA Loop Calibration
4 9 16
Multifunction Calibrators................. 5 Digital Pressure Calibrators........... 10 Handheld Temperature Calibrators.17
Documenting Process Calibrator..............5 Pressure Calibrator...................................10 RTD Process Calibrator............................17
Documenting Process Calibrator Pressure Calibrator with Pump..............10 Thermocouple Calibrator.........................17
with HART....................................................5 Portable Electric Pressure Calibrator....10 Temperature Calibrator............................17
Precision Process Calibrator.....................5 IS Pressure Calibrator..............................10
Multifunction Field Temp Sources.. 17
Precision Multifunction Pressure Modules......................................11
Process Calibrator.......................................6 Field Metrology Wells..............................17
IS Pressure Modules.................................11
Multifunction Process Calibrator.............6
Dual Range Pressure Calibrator.............11 Field Temperature Sources............ 18
Digital Multimeters.....................................6
Pressure Modules......................................11 Handheld Dry-Wells.................................18
Precision Multimeters................................6
IS Pressure Modules.................................11 Dual-Well Dry-Well..................................18
mA Loop Calibrators........................ 7 Field Dry-Wells..........................................18
Pressure Comparators and Master
Loop Calibrators..........................................7 Gauges........................................... 12 Ultra-Cool Field Metrology Well.............18
IS Loop Calibrator.......................................7 Gas Pressure Comparators......................12 Thermocouple Furnace............................19
Precision Loop Calibrator..........................7 Precision Pressure Gauge Calibrator.....12 Micro-Baths................................................19
Precision Loop Calibrator with HART.....7 Reference Pressure Gauges.....................12 Metrology Wells........................................19
Communications/Diagnostics...................7
Reference Pressure Calibrators...... 13 Infrared Temperature Sources....... 19
Volt/mA Calibrator......................................8
Portable Pressure Calibrator...................13 Precision IR Calibrators...........................19
ProcessMeter ™ Tools...................................8
Field IR Calibrators...................................19
Milliamp Clamp Meters..............................8 Bench Deadweight Testers............. 13
Milliamp Process Clamp Meters...............8 Pneumatic Deadweight Tester................13 Thermometer Standards................. 20
Precision PRTs............................... 21
Thermistors................................... 21
Software.......................................................................................22
Accessories.................................................................................22
753 Documenting
Process Calibrator
753 Rugged handheld tool for sourc-
ing, simulating and measuring
pressure, temperature, and elec-
trical signals. 7526A Precision
• Measure volts, mA, RTDs, Process Calibrator
thermocouples, frequency, and
ohms to test sensors, transmit- Best balance of economy and
ters and other instruments accuracy for calibration of
• Source/simulate volts, mA, ther- temperature and pressure process
mocouples, RTDs, frequency, measurement instrumentation.
ohms, and pressure to calibrate • Sources and measures dc volt-
transmitters age, current, resistance, RTDs
• Power transmitters during test and thermocouples
using loop supply with simulta- • Measures pressure using Fluke
neous mA measurement 700/525A-P pressure modules
• Download procedures and • Includes 24 V dc loop power
754
upload calibration results from supply, automated switch-test
field calibrations function and measures 4 mA to
20 mA
www.fluke.com/753
www.flukecal.com/7526A
mA Loop Calibrators
Fluke loop calibrators are
ideal for a wide variety
of calibration applications
from 4 to 20 mA.
771/772/773
10 Process Calibration
Pressure and Flow Calibration
Tools
721
700P
16 Temperature Calibration
Multifunction
Field Temperature
Sources
712 9142/9143/9144 Fast, lightweight and
portable with precision
Handheld temperature control
traceable to national
Temperature standards. Suitable for
Calibrators calibration of thermocouples,
Suitable for calibrating RTDs, PRTs, and other
temperature transmitters, temperature sensors.
panel meters, and other
devices that connect to
9142 Field Metrology Well
temperature sensors.
Maximizing portability, speed,
and functionality for the indus-
712 RTD Process Calibrator trial process environment.
Delivers outstanding performance, • –25 °C to 150 °C temperature
714 durability and reliability in a range
compact, lightweight, and easy- • Display accuracy of ± 0.2 °C
to-carry tool. over full range
• Measure temperature from RTD • Built-in two-channel readout
probe output for PRT, RTD, thermocouple,
• Simulate RTD output 4-20 mA current
• Measure additional RTDs using • Optional built-in reference
ohms measurement function thermometer readout
• Simulate additional RTDs using www.flukecal.com/9142
ohms source function
www.fluke.com/712
9143 Field Metrology Well
Maximizing portability, speed,
714 Thermocouple and functionality for the indus-
Calibrator trial process environment.
Delivers outstanding performance, • 33 °C to 350 °C temperature
724 durability and reliability in a range
compact, lightweight, and easy- • Display accuracy of ± 0.2 °C
to-carry device. over full range
• Measure temperature from TC • Built-in two-channel readout
probe output for PRT, RTD, thermocouple,
• Simulate TC output 4-20 mA current
• Calibrate linear TC transmitter • Optional built-in reference
with mV source function thermometer readout
www.fluke.com/714 www.flukecal.com/9143
Temperature Calibration 17
9100S 9102S 9103/9140/9141
18 Temperature Calibration
9150 6102/7102/7103 9170/9171/9172/9173
9170/9171/9172/9173
Metrology Wells 9132/9133 Field
Best possible accuracy in a Infrared Calibrators
dry-block calibrator Precision when you need it for
• Best performing industrial tem- infrared temperature calibration.
perature sources in the world • Verify IR pyrometers from
(stability as good as ±0.005 °C) –30 °C to 500 °C
• Immersion depth to 203 mm (–22 °F to 932 °F)
(8 in) • RTD reference well for contact 9133
• Optional built-in readout reads temperature measurement
reference PRTs to ± 0.006 °C www.flukecal.com/913X
• Ranges:
- 9170: –45 °C to 140 °C
- 9171: –30 °C to 155 °C
- 9172: 35 °C to 425 °C
- 9173: 50 °C to 700 °C
www.flukecal.com/917X
Temperature Calibration 19
Thermometer 1586A Super-DAQ Precision
Standards Temperature Scanner
Delivering exceptional The 1586A Super-DAQ provides
accuracy, wide measurement multi-channel data acquisition for
range, and designed to voltage, resistance, and current,
go where you work. with category leading tempera-
ture measurement accuracy.
• Measure thermocouples, PRTs,
1551A Ex/1552A Ex “Stik” thermistors, dc voltage, dc cur-
Thermometer rent, and resistance
1551A Ex/1552A Ex The best substitute for • Excellent temperature measure-
precision mercury-filled ment accuracy:
glass thermometers. - PRTs: ± 0.005 °C (using exter-
• Accuracy of ± 0.05 °C nal DAQ-STAQ Multiplexer
(± 0.09 °F) over full range - Thermocouples (using High-
• Intrinsically safe (ATEX and Capacity Module w/int. CJC):
IECEx compliant) ± 0.5 °C
• Two models to choose from - Thermistors: ± 0.002 °C
(-50 °C to 160 °C or -80 °C to • Up to 40 isolated input channels
300 °C) • Selectable scan speeds: Maxi-
www.flukecal.com/155X
mum of 10 channels per second
• On-board calibration routines
control Fluke dry-wells and
1523/1524 Handheld baths for automated sensor
Thermometer Readout calibration.
1523/1524 Measure, graph and record three www.flukecal.com/1586A
sensor types with one tool.
• High accuracy: PRTs:
± 0.011 °C; Thermocouples: Ambient Conditions
± 0.24 °C; Thermistors: Monitor
± 0.002 °C For precise measurement
• A simple user interface to see and recording of ambient
trends quickly temperature and humidity
• Smart connectors to load probe conditions wherever
information automatically calibrations take place.
www.flukecal.com/152X
1620A Precision
1502A/1504 1502A/1504 Thermometer Thermo-Hygrometer
Readouts The most accurate temperature
Best performance thermometers in and humidity graphical data
their price range. logger on the market.
• Single-channel reference • Superior accuracy
thermometers, accurate to • Network enabled
±0.006 °C (meter only) • Powerful logging and
• Two models to choose from— analysis tools
reading PRTs or thermistors • Measures temperature to
• Best price/performance package ± 0.125 °C and humidity to
www.flukecal.com/150X ± 1.5 % on two channels
www.flukecal.com/1620A
20 Temperature Calibration
Precision PRTs 5618B Small Diameter
High accuracy reference Industrial RTD
temperature measurements Fast response for time-dependent
in temperature sources on measurements.
the bench or in the field. • Small diameter sheath, 3.2 mm
(0.125 in)
5627A Precision • Excellent stability
• Includes ITS-90 coefficients
Industrial PRT
www.flukecal.com/5618B
5627A 5615 • Vibration and shock resistant
• NVLAP-accredited calibration
included, lab code 200706-0 5606 Full Immersion PRT
• Calibration accuracy of Fully immerse PRT transition
± 0.046 °C at 0 °C junction inside freezers or
• Available with a 90° bend furnaces.
www.flukecal.com/5627 • Transition junction designed
to withstand full temperature
range of probe
5615 Secondary Reference • -200 °C to 160 °C
5608/5609/5609-BND Temperature Standards • Calibration accuracy of
• –200 °C to 420 °C ± 0.05 °C (full range)
• Calibrated accuracy ± 0.010 °C www.flukecal.com/5606
at 0 °C
• NVLAP-accredited calibration
included, lab code 200706-0 Thermistors
Providing accurate and
www.flukecal.com/5615
rugged temperature
measurements from
5608/5609/5609-BND 0 °C to 100 °C.
5622 5618B Secondary Reference PRTs
Drift rate of ± 0.01 °C at 0 °C after 5610/5611/5611T
100 hours at max temperature. Secondary Reference
• 5608: –200 °C to 500 °C
(80 mm minimum immersion)
Thermistor Probes
• 5609: –200 °C to 670 °C Economical lab-grade therm-
(100 mm minimum immersion) istor probes with low drift
• Optional, NVLAP-accredited susceptibility.
calibration, lab code 200348-0 • Short-term accuracy to
www.flukecal.com/5608
± 0.01 °C; one-year drift
5606/5607 < ± 0.01 °C
• 5610: 3.2 mm diameter stain-
5622 Fast Response PRTs less steel sheathed thermistor
• T ime constants as fast as • 5611: 1.5 mm diameter (tip)
0.4 seconds silicone coated thermistor
• Available as DIN/IEC Class A • 5611T: 3 mm diameter (tip)
PRTs or with NVLAP-accredited PTFE encapsulated thermistor
calibration, lab code 200348-0 • Optional, NVLAP-accredited
• Small probe diameters ranging calibration
from 0.5 mm to 3.2 mm (four www.flukecal.com/5610
models available)
www.flukecal.com/5622
5610 5611
5611T
Temperature Calibration 21
Software/
Accessories
22 Software/Accessories
Software
700PTP-1 Pneumatic
700G/Track Test Pump
Easy-to-use software for managing
The 700PTP-1 is a handheld
instruments and calibration data.
pressure pump designed to 700LTP-1
• Enables data download and
generate either vacuum to
logging configurations to
-11.6 psi/-0.8 bar or pressure
the 700G Series gauges for a
to 600 psi/40 bar.
remote logging event
• Configure logging event reading www.fluke.com/process_acc
rate, duration and measurement
units 700LTP-1 Low Pressure
• Upload measurements logged Test Pump
remotely and display or export
Hand operated pressure pump
measurements
designed to generate either
www.fluke.com/700Gsoftware vacuum to -13 psi/-.90 bar or
pressures to 100 psi/6.9 bar. Ideal
LogWare for low pressure applications
requiring accurate low pressure
Turn a Fluke Calibration single- testing.
channel handheld or 1502A/1504
www.fluke.com/process_acc
readout into a real-time data
logger.
• Collects realtime data
• Calculates statistics and
displays customizable graphs
• Allows user-selected start
times, stop times and sample
intervals
www.flukecal.com/logware
Software/Accessories 23
Fluke. The Most Trusted Tools in the World.
Fluke Corporation Fluke Europe B.V.
PO Box 9090, PO Box 1186, 5602 BD
Everett, WA 98206 U.S.A. Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or Fax (905) 890-6866
From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2012-2014 Fluke Corporation. Specifications subject to change without notice.
Printed in U.S.A. 2/2014 4181108C_EN