Sie sind auf Seite 1von 24

Process Calibration Tools

A full range of accurate, rugged and reliable calibration solutions


for field and bench applications

Electrical, Multifunction,
and mA Loop Calibration

Pressure and Flow Calibration

Temperature Calibration
Process Calibration Tools
From Fluke and Fluke Calibration

Working in a process environment such as pharmaceutical, refining or other


industrial area can be challenging. Whether you’re working at a bench, out
in the plant, or in the field, you need accurate tools that you can count on.

Finding the right tools for the specific challenges you face every day is important, so
we’ve provided an “at-a-glance” guide to the wide range of multifunction, mA loop,
pressure and temperature calibrators that we carry. For complete information on
our field and bench solutions to all your calibration needs visit www.fluke.com,
www.flukecal.com, or one of the product pages listed in this catalog.

Electrical and multifunction calibration


Fluke offers a broad range of field and bench calibrators to source, simulate,
and measure pressure, temperature, and electrical signals to help you verify
and adjust your test equipment or almost any process instrument.

mA loop calibration
Loop calibrators are essential tools for working with 4-20 mA current loops. Fluke loop
calibrators provide mA sourcing, simulation and measurement, readouts in both mA
and % of span, 24 V loop supply, simple operation and accuracy you can count on.

Pressure and flow calibration


Pressure, level and flow instrumentation is found in virtually every process plant.
Periodic calibration of these instruments is required to keep plants operating efficiently
and safely. Fluke provides a wide selection of field and bench calibration tools to help
you quickly and reliably calibrate your pressure and gas flow instrumentation.

Temperature calibration
Temperature calibration refers to the calibration of any device used in a system that
measures temperature—from sensors to transmitters to displays. Fluke offers bench and
field solutions to ensure process temperature accuracy of not only the system’s electronic
temperature signals, but also the very temperature sensors that initiate those signals.

2 Process Calibration Tools


Process Calibration Tools

Electrical,
Pressure and Temperature
Multifunction, and
Flow Calibration Calibration
mA Loop Calibration
4 9 16
Multifunction Calibrators................. 5 Digital Pressure Calibrators........... 10 Handheld Temperature Calibrators.17
Documenting Process Calibrator..............5 Pressure Calibrator...................................10 RTD Process Calibrator............................17
Documenting Process Calibrator Pressure Calibrator with Pump..............10 Thermocouple Calibrator.........................17
with HART....................................................5 Portable Electric Pressure Calibrator....10 Temperature Calibrator............................17
Precision Process Calibrator.....................5 IS Pressure Calibrator..............................10
Multifunction Field Temp Sources.. 17
Precision Multifunction Pressure Modules......................................11
Process Calibrator.......................................6 Field Metrology Wells..............................17
IS Pressure Modules.................................11
Multifunction Process Calibrator.............6
Dual Range Pressure Calibrator.............11 Field Temperature Sources............ 18
Digital Multimeters.....................................6
Pressure Modules......................................11 Handheld Dry-Wells.................................18
Precision Multimeters................................6
IS Pressure Modules.................................11 Dual-Well Dry-Well..................................18
mA Loop Calibrators........................ 7 Field Dry-Wells..........................................18
Pressure Comparators and Master
Loop Calibrators..........................................7 Gauges........................................... 12 Ultra-Cool Field Metrology Well.............18
IS Loop Calibrator.......................................7 Gas Pressure Comparators......................12 Thermocouple Furnace............................19
Precision Loop Calibrator..........................7 Precision Pressure Gauge Calibrator.....12 Micro-Baths................................................19
Precision Loop Calibrator with HART.....7 Reference Pressure Gauges.....................12 Metrology Wells........................................19
Communications/Diagnostics...................7
Reference Pressure Calibrators...... 13 Infrared Temperature Sources....... 19
Volt/mA Calibrator......................................8
Portable Pressure Calibrator...................13 Precision IR Calibrators...........................19
ProcessMeter ™ Tools...................................8
Field IR Calibrators...................................19
Milliamp Clamp Meters..............................8 Bench Deadweight Testers............. 13
Milliamp Process Clamp Meters...............8 Pneumatic Deadweight Tester................13 Thermometer Standards................. 20

Hydraulic Deadweight Testers...............14 Stik Thermometer.................................... 20

Electronic Deadweight Testers...............14 Handheld Thermometer Readout.......... 20


Four-Channel Thermometer Readout... 20
Bench Pressure Controllers............ 15 Thermometer Readouts........................... 20
Pressure Controller/Calibrators..............15 Precision Temperature Scanner............ 20
Flow Calibrators............................. 15 Ambient Conditions Monitor.......... 20
Gas Flow Calibrators................................15 Precision Thermo-Hygrometer.............. 20

Precision PRTs............................... 21

Thermistors................................... 21

Software.......................................................................................22
Accessories.................................................................................22

Process Calibration Tools 3


Electrical,
Multifunction,
and mA Loop
Calibration

4 Electrical, Multifunction, and mA Loop Calibration


Multifunction
Calibrators
These field and bench
calibrators source, simulate,
and measure pressure,
temperature, and electrical
signals with exceptional
precision.

753 Documenting
Process Calibrator
753 Rugged handheld tool for sourc-
ing, simulating and measuring
pressure, temperature, and elec-
trical signals. 7526A Precision
• Measure volts, mA, RTDs, Process Calibrator
thermocouples, frequency, and
ohms to test sensors, transmit- Best balance of economy and
ters and other instruments accuracy for calibration of
• Source/simulate volts, mA, ther- temperature and pressure process
mocouples, RTDs, frequency, measurement instrumentation.
ohms, and pressure to calibrate • Sources and measures dc volt-
transmitters age, current, resistance, RTDs
• Power transmitters during test and thermocouples
using loop supply with simulta- • Measures pressure using Fluke
neous mA measurement 700/525A-P pressure modules
• Download procedures and • Includes 24 V dc loop power
754
upload calibration results from supply, automated switch-test
field calibrations function and measures 4 mA to
20 mA
www.fluke.com/753
www.flukecal.com/7526A

754 Documenting Process


Calibrator with HART
Rugged, reliable tool for cali-
brating, maintaining, and
troubleshooting HART and
other instrumentation.
• Measure volts, mA, RTDs,
7526A thermocouples, frequency, and
ohms to test sensors, transmit-
ters and other instruments
• Source/simulate volts, mA, ther-
mocouples, RTDs, frequency,
ohms, and pressure to calibrate
transmitters
• Supports popular models of
HART transmitters, with more
device-specific command sup-
port than any other HART field
calibrator
• Download procedures and
upload calibration results from
field calibrations
www.fluke.com/754

Electrical, Multifunction, and mA Loop Calibration 5


726 725 725Ex

726 Precision Multifunction 725EX IS Multifunction


Process Calibrator Process Calibrator
Designed specifically for the Easy-to-use, intrinsically safe
process industry with broad field calibrator can calibrate
workload coverage, calibration almost any process instrument
power and unsurpassed accu- needing service where explosive
racy. Includes all the features and gasses may be present.
functions of the 725 below plus: • ATEX II 1 G Ex ia IIB 171 °C
8808A • Enhanced accuracy KEMA 04ATEX 1303X
• Pulse count sourcing and pulse • I.S. Class I, Division 1 Groups
measurement totalizing B-D, 171 °C compliance
• Pressure switch test • Measure Volts dc, mA, RTDs,
• Error % calculation thermocouples, frequency and
www.fluke.com/726 ohms
• Source or simulate volts dc, mA,
RTDs, thermocouples, frequency
725 Multifunction Process and ohms
Calibrator • Measure/source pressure using
A powerful and easy-to-use field any of eight Fluke 700PEX
8845A/8846A Pressure Modules
calibrator to test and calibrate
almost any process parameter. www.fluke.com/725EX
• Measure volts, mA, RTDs,
thermocouples, frequency,
and ohms to test sensors and 8808A Digital Multimeter
transmitters Versatile multimeter for
• Source/simulate volts, mA, ther- manufacturing, development
mocouples, RTDs, frequency, and service applications.
ohms, and pressure to calibrate • 5.5 digit resolution
transmitters • Basic V dc accuracy of 0.015 %
• Measure/source pressure • Dual display
using any of 29 Fluke 700Pxx www.flukecal.com/8808A
Pressure Modules
• Source mA with simultaneous
pressure measurement to
8845A/8846A Precision
conduct valve and I/P tests Multimeters
www.fluke.com/725 Precision and versatility for bench
or systems applications.
• 6.5 digit resolution
• Basic V dc accuracy of up to
0.0024 %
• Dual display
www.flukecal.com/8845A

6 Electrical, Multifunction, and mA Loop Calibration


709 709H

mA Loop Calibrators
Fluke loop calibrators are
ideal for a wide variety
of calibration applications
from 4 to 20 mA.

705 Loop Calibrator


A cost-effective, integrated solu- 709 Precision Loop
tion for calibration, repair and Calibrator
maintenance of current loops. Reduces the time it takes to
• mA sourcing, simulation and measure or source voltage or
measurement current and power up a loop.
705 • Simultaneous mA and % of • Best-in-class accuracy at 0.01%
span display reading
• 24 V loop supply with mA • Small rugged design operates
measure on six standard AAA batteries
• 0 V dc to 28 V dc measurement • Intuitive user interface with
to check loop voltage Quick-Set knob for fast setup,
www.fluke.com/705 easy use
• Built-in selectable 250 Ω resistor
707 Loop Calibrator for HART communication
• 24 V dc loop power with mA
A high performance, extremely Measure Mode (-25% to 125%)
fast and easy-to-use solution for • Resolution of 1 µA on mA ranges
calibration, repair and mainte- and 1 mV on voltages ranges
nance of current loops.
www.fluke.com/709
• mA sourcing, simulation and
707 measurement
• 24 V loop supply with mA 709H Precision Loop
measure, including 250 Ω HART Calibrator with HART
resistor Communications/Diagnostics
• 0 V dc to 28 V dc measurement
to check loop voltage Designed to save time and
produce high-quality results
www.fluke.com/707
• HART Communication built
in for easy HART device
707EX IS Loop Calibrator maintenance
An intrinsically safe option for use • Best-in-class accuracy at 0.01%
in explosion endangered areas— reading
certified in accordance with the • Small rugged design operates
ATEX directive (Ex II 2 G Ex ia IIC on six standard AAA batteries
T4) in Zones 1 and 2. • Intuitive user interface with
• 1 µA resolution for mA source, Quick-Set knob for fast setup,
707EX simulate and measure easy use
• Measures V dc to 28 V • Built-in selectable 250 Ω resistor
• 0-20 mA or 4-20 mA default for HART communication
startup modes • 24 V dc loop power with mA
• HART® compatible resistance Measure Mode (-25% to 125%)
is connected in series with the • Resolution of 1 µA on mA ranges
loop supply for compatibility and 1 mV on voltage ranges
with HART communicators www.fluke.com/709H
www.fluke.com/707EX

Electrical, Multifunction, and mA Loop Calibration 7


715 Volt/mA Calibrator 771 Milliamp Process Clamp
Outstanding performance, Meter
durability and reliability. Saves time by making fast, accu-
• Measure loop current (0-20 mA, rate measurements on 4-20 mA
4-20 mA) signals with very signal loops without breaking the
high accuracy of 0.015% and 1 circuit.
mA resolution • 0.01 mA resolution and
• Measure voltage output process sensitivity
signals from PLCs, transmitters • Measure mA signals for PLC and
• Source or simulate 24 mA loop control system analog I/O
current • Measure 10 to 50 mA signals in
• Source voltage to 100 mV or 10 V older control systems using the
• 24 V loop supply with simultane- 99.9 mA range
715
ous current measurement www.fluke.com/771
• Enhanced voltage and current
measure and source accuracy
772 Milliamp Clamp Meter
www.fluke.com/715
Expanded features of the popular
771 mA Clamp Meter by adding
787 ProcessMeter™ loop power and mA sourcing to
A complete troubleshooting solu- the capabilities.
tion in the palm of your hand • Measure 4 to 20 mA signals
with a digital multimeter and loop with in-circuit measurement
calibrator in one tool. • Simultaneous mA in-circuit
• 1000 V overload protection measurement with 24 V loop
on V, ohms, frequency power for powering and testing
• 150 V overload protection on transmitters
mA, backed up by 440 mA • Source 4 to 20 mA signals for
787 1000 V fuse testing control system I/O or I/Ps
• 25 % manual step plus auto • Automatically ramp or step the
step and auto ramp on mA 4 to 20 mA output for remote
output testing
• CAT III 1,000V rating www.fluke.com/772
www.fluke.com/787

773 Milliamp Process Clamp


789 ProcessMeter™ Meter
The 789 includes all the popular The premier mA clamp meter,
features of the 787 and adds: adds advanced troubleshooting
• 24 V loop power supply features and voltage source/
• 1200 ohm drive capability on measure for testing voltage I/O.
mA source Icludes all the features of the
• HART mode setting with loop 772 plus:
power and a built-in 250 ohm • DC voltage sourcing and mea-
789 resistor surement, verify 24 V power
• 0 % and 100 % buttons to supplies or test voltage I/O
toggle between 4 and 20 mA signals
sourcing for a quick span check • Scaled mA output provides
• CAT IV 600 V rating a continuous mA signal that
www.fluke.com/789
corresponds to the 4 to 20 mA
signal measured by the mA
clamp
• Simultaneously source and
measure mA signals
www.fluke.com/773

771/772/773

8 Electrical, Multifunction, and mA Loop Calibration


Pressure and
Flow Calibration

Pressure and Flow Calibration 9


717 718 718EX

Digital Pressure Calibrators


Built-in features like mA measure, loop power, switch test
and transmitter error calculation make these pressure
calibrators powerful tools that are easy to use.

717 Pressure Calibrator 719 and 719PRO Portable


Rugged, reliable and accurate Electric Pressure Calibrators
calibrator with outstanding per- Calibrate and test pressure devices
formance and durability. quickly and easily with the built-in
719PRO • Measure pressure, 0.025 % of electric pump.
full scale with internal sensor • Source mA with simultaneous
up to 10,000 psi/690 bar sensor pressure measurement to test
(10000G model) valves and I/Ps
• Measure mA with 0.015 % • Simulate mA signals to trouble-
accuracy and 0.001 mA resolu- shoot 4-20 mA loops
tion, while sourcing 24 V loop • Power transmitters during test
power using 24 V loop supply with
• Measure pressure to 10,000 psi/ simultaneous mA measurement
700 bar using one of 29 Fluke • New 300 psi range, generate
700Pxx Pressure Modules up to 300 psi, with internal
www.fluke.com/717 Electric pump (719PRO)
• Precision temperature measure-
ment combined accuracy of
718 Pressure Calibrator ± 0.25 °C (0.45 °F) when using
with Pump 720 RTD probe (optional
Provides a total pressure calibra- accessory for use with 719PRO)
tion solution for transmitters, www.fluke.com/719
gauges and switches.
• Pressure source and milliamp
measurement to calibrate and 718EX IS Pressure Calibrator
maintain almost any pressure A powerful, intrinsically safe and
device self-contained pressure calibrator
• Integrated pump is easily for use in explosion endangered
cleaned when accidently areas.
exposed to fluids that reduces • ATEX II 1G Ex ia IIC T4
cost of ownership and repairs compliant
and enables servicing the pump • Built-in pressure/vacuum hand
in the field pump, with fine adjust vernier
• 1 psi, 30 psi, 100 psi and and bleed valve
300 psi ranges mean few extra • 30 psi, 100 psi, and 300 psi
tools required ranges (2 bar, 7 bar, and
www.fluke.com/718 20 bar)
• Pressure measurement to
200 bar using any of eight
intrinsically safe Fluke 700PEx
Pressure Modules
www.fluke.com/718EX

10 Process Calibration
Pressure and Flow Calibration
Tools
721

700P

721 Dual Range Pressure 700P Pressure Modules


Calibrator A full range of differential, gage,
Two measurement ranges plus absolute, vacuum, dual and intrin-
*temperature measurement make sically safe pressure modules are
the 721 ideal for gas custody available, from -15 psi (-103 kPa)
transfer calibration applications. to 10,000 psi (69 MPa).
• Fourteen models • Best-in-class 0.025 % reference
• Up to (3) displayed measure- uncertainty
ment simultaneously • Rugged, chemical-resistant
• Simplified user interface for packaging
ease of use • Temperature compensated 700PEX
• Rugged, durable design with using proprietary micro-tech-
protective holster nology linearized output
• High accuracy, 0.025% total • Digital communication to
measurement uncertainty for calibrators; no analog losses or
one year errors
• Pt100 RTD input for precise www.fluke.com/700P
temperature measurement,
accurate to 0.1°C (0.2°F) 700PEx IS Pressure Modules
• Requires 720RTD probe sold Intrinsically safe pressure mod-
separately as an accessory ules to create a complete pressure
www.fluke.com/721 test solution.
• Includes NIST-traceable calibra-
tion certificate
• Certified by CSA: I.S. Class I,
Div 1, Groups A-D T4, Ta = 0 °C
to 50 °C
• ATEX II 1G Ex ia IIC T4
compliant
www.fluke.com/700PEX

Pressure and Flow Calibration 11


P5513 P5514
P5510

Pressure P5515 Hydraulic


Comparators and Pressure Comparator
Master Gauges High quality, precise hydraulic
pressure generation and control.
Precise pressure generation
• Generate and precisely adjust
for comparing a device pressure to 140 MPa
under test to a master (20,000 psi)
gauge. • Integrated hand pump for
system priming and large
P5510 Gas volume applications
P5515 • Compatible with a wide range
Pressure Comparator
of fluids
Easy, efficient pressure and
www.flukecal.com/P5515
vacuum generation in a single
device.
• Pressure to 2 MPa (300 psi) 700G Precision Pressure
• Vacuum to -80 kPa (-12 psi) Gauge Calibrator
www.flukecal.com/P5510 Rugged construction for reliable
measurements in the field.
P5513 Gas • Twenty-three ranges from 10
Pressure Comparator inH20/1 bar to 10,000 psi/690
bar and 0.05 % accuracy
High quality, precise gas pressure • Combine with a comparator kit
generation and control. for a complete solution
• Precise pressure regulation to • Four new absolute pressure
700G
21 MPa (3000 psi) with high measurement ranges
quality needle valves • Use the 700G/TRACK Software
• Built-in screw press for fine to upload over 8,000 logged
pressure adjustment pressure measurements
www.flukecal.com/P5513 • Up to 1500 hours battery life
• I.S. rating, CSA; Class 1, Div 2,
P5514 Hydraulic Groups A-D rating, ATEX: rating:
Pressure Comparator II 3 G Ex nA IIB T6
www.fluke.com/700G
Easy, efficient hydraulic pressure
generation.
• Generate and precisely adjust 2700G Series Reference
pressure to 70 MPa (10,000 psi) Pressure Gauges
• Compatible with a wide range Best-in-class accuracy from a
of fluids master pressure gauge.
2700G
www.flukecal.com/P5514 • Precision pressure measurement
from 100 kPa (15 psi) to 70 MPa
(10,000 psi).
• Accuracy to ± 0.02% of
full scale
• Combine with the P55XX
Pressure Comparators for a
complete benchtop pressure
calibration solution
www.flukecal.com/2700G

12 Pressure and Flow Calibration


3130 P3010/P3020/P3030

Reference Pressure Bench Deadweight


Calibrators Testers
Portable, high-quality Deadweight testers are
pressure gauges highly accurate, robust
and flexible pressure
3130 Portable measurement standards
Pressure Calibrator capable of calibrating a wide
range of instruments.
Everything you need for highly
accurate calibrations of pneumatic
field instruments. P3010 Single Piston Gas P3030 High Pressure Gas
• Measure and generate pres- Deadweight Tester Deadweight Tester
sures from -80 kPa to 2 MPa A high quality, high performance Innovative liquid-lubricated piston
(-12 to 300 psi) gas deadweight tester. offers low drop rates and high
• Accuracy of ±0.025% reading • 0.015 % of reading accuracy tolerance to contamination.
plus ±0.01% FS (0.008 % optional) • 0.015 % of reading accuracy
• Works with compressed plant • Ranges cover from -100 kPa (0.008 % optional)
air or internal pump (-15 psi) vacuum to 3.5 MPa • Ranges cover from 100 kPa
• 24 V loop power and electrical (500 psi) pressure (10 psi) to 14 MPa (2000 psi)
measurement for transmitters • Integrated vacuum/pressure • Integrated control valves and
and switches pump available to 2 MPa screw press for fine adjustment
• Compatible with Fluke 700P (300 psi) www.flukecal.com/P3030
pressure modules
www.flukecal.com/P3010
• NiMH battery
www.flukecal.com/3130
P3020 Dual Piston Gas
Deadweight Tester
Unique suspended piston design
offers vacuum and pressure cali-
bration in a single instrument.
• 0.015 % of reading accuracy
(0.008 % optional)
• Ranges cover from 1.5 kPa
(5 in H 2O) to 3.5 MPa (500 psi)
• All models feature vacuum
measurement to -100 kPa
(-15 psi)
• Integrated vacuum/pressure
pump available to 2 MPa
(300 psi)
www.flukecal.com/P3020

Pressure and Flow Calibration 13


P3110/P3120 P3210/P3220 P3800

P3110 Single Piston Oil P3800 High Pressure Oil


Deadweight Tester Deadweight Tester
High quality, high performance, High performance, easy to use
easy to use oil pressure calibration. very high pressure oil calibration.
• 0.015 % of reading accuracy • 0.02 % of reading accuracy
(0.008 % optional) (0.015 % optional)
• Ranges cover from 100 kPa • Ranges up to 400 MPa
(10 psi) to 140 MPa (20,000 psi) (60,000 psi)
• Integrated pressure generation • Integrated pressure generation,
and control is standard intensifier and control
6531 www.flukecal.com/P3110 www.flukecal.com/P3800

P3120 Dual Piston Oil 6531 Electronic Deadweight


Deadweight Tester Tester
Dual piston design offers maxi- A digital alternative to the tradi-
mum hydraulic pressure tional deadweight tester.
calibration workload coverage. • 0.02 % of reading from 10 % to
• 0.015 % of reading accuracy 100 % of instrument range
(0.008 % optional) (10:1 turndown)
• 100 kPa (10 psi) to 110 MPa • Ranges from 7 MPa (1000 psi)
(16,000 psi) in a single to 200 MPa (30,000 psi)
instrument • Integrated hydraulic pressure
6532 generation and control
• Integrated pressure generation
and control is standard • Compatible with water and a
www.flukecal.com/P3120
wide range of oils and other
fluids
• Onboard test routines, data
P3210 Single Piston Water storage, and other advanced
Deadweight Tester features
Specially designed to use water as www.flukecal.com/6531
a test medium.
• 0.015 % of reading accuracy 6532 Extended Range
(0.008 % optional)
Electronic Deadweight
• Ranges cover from 100 kPa
(10 psi) to 70 MPa (10,000 psi) Tester
• Integrated pressure generation All the features of model 6531
and control is standard with extended pressure range for
www.flukecal.com/P3210 maximum workload coverage.
• 0.02 % of reading from 1 %
to 100 % of instrument range
P3220 Dual Piston Water (100:1 turndown)
Deadweight Tester • Models with full scale ranges
Dual piston design offers maximum from 70 MPa (10,000 psi) to
water pressure calibration workload 200 MPa (30,000 psi)
coverage. www.flukecal.com/6532
• 0.015 % of reading accuracy
(0.008 % optional)
• 100 kPa (10 psi) to 70 MPa
(10,000 psi) in a single
instrument
• Integrated pressure generation
and control is standard
www.flukecal.com/P3220
14 Pressure and Flow Calibration
Flow Calibrators
Simple to understand
and use, with features,
rangeability and performance
to cover most low gas flow
calibration applications.

5141 Gas Flow Calibrator


Easy to use and reliable gas flow
calibration.
• 0.5 % of reading accuracy from
6241/6242
10 % to 100 % of instrument
range (10:1 turndown)
Bench Pressure • Ranges from 0 to 100 sccm to
0 to 50 slm
Controllers • Real-time fully compensated
High performance, with mass flow display
powerful features for a • Calibrated for use in N2 and
wide range of pneumatic air, with corrections for a wide
pressure calibrations. range of other test gases
• Integrated gas regulation and
6241 Pressure Controller/ control provides a precise,
uninterrupted flow source
Calibrator
• Unique design allows test line
Fully automated, reliable, easy to pressures of more than
use gas pressure calibration. 350 kPa gauge (50 psi gauge)
• 0.02 % accuracy of any span
www.flukecal.com/5141
from 10 % to 100 % of instru-
ment range (10:1 turndown) 5141/5142
• Ranges from ± 15 kPa (± 2 psi) 5142 Extended Range Gas
to 14 MPa (2000 psi) Flow Calibrator
• Best-in-class control preci- All the features of model 5141
sion with very wide control with extended flow range for
turndown maximum workload coverage.
• Absolute, gauge and bidirec- • 0.5 % of reading accuracy from
tional gauge modes included in 1 % to 100 % of instrument
most models range (100:1 turndown)
• Onboard test routines, data 5144
• Ranges from 0 to 1 slm to 0 to
storage, and other advanced 50 slm
features
www.flukecal.com/5142
www.flukecal.com/6241

5144 Dual Extended Range


6242 Extended Range Gas Flow Calibrator
Pressure Controller/
Dual extended gas flow elements
Calibrator offer a complete, very wide range
All the features of model calibration system.
6241 with extended pressure • 0.5 % of reading accuracy from
range for maximum workload 10 sccm to 50 slm
coverage.
www.flukecal.com/5144
• 0.02 % accuracy of any span
from 1 % to 100 % of instru-
ment range (100:1 turndown)
• Ranges from ± 100 kPa
(± 15 psi) to 14 MPa (2000 psi)
www.flukecal.com/6242

Pressure and Flow Calibration 15


Temperature
Calibration

16 Temperature Calibration
Multifunction
Field Temperature
Sources
712 9142/9143/9144 Fast, lightweight and
portable with precision
Handheld temperature control
traceable to national
Temperature standards. Suitable for
Calibrators calibration of thermocouples,
Suitable for calibrating RTDs, PRTs, and other
temperature transmitters, temperature sensors.
panel meters, and other
devices that connect to
9142 Field Metrology Well
temperature sensors.
Maximizing portability, speed,
and functionality for the indus-
712 RTD Process Calibrator trial process environment.
Delivers outstanding performance, • –25 °C to 150 °C temperature
714 durability and reliability in a range
compact, lightweight, and easy- • Display accuracy of ± 0.2 °C
to-carry tool. over full range
• Measure temperature from RTD • Built-in two-channel readout
probe output for PRT, RTD, thermocouple,
• Simulate RTD output 4-20 mA current
• Measure additional RTDs using • Optional built-in reference
ohms measurement function thermometer readout
• Simulate additional RTDs using www.flukecal.com/9142
ohms source function
www.fluke.com/712
9143 Field Metrology Well
Maximizing portability, speed,
714 Thermocouple and functionality for the indus-
Calibrator trial process environment.
Delivers outstanding performance, • 33 °C to 350 °C temperature
724 durability and reliability in a range
compact, lightweight, and easy- • Display accuracy of ± 0.2 °C
to-carry device. over full range
• Measure temperature from TC • Built-in two-channel readout
probe output for PRT, RTD, thermocouple,
• Simulate TC output 4-20 mA current
• Calibrate linear TC transmitter • Optional built-in reference
with mV source function thermometer readout
www.fluke.com/714 www.flukecal.com/9143

724 Temperature Calibrator 9144 Field Metrology Well


Powerful and easy to use to Precision calibration with fast
measure and source functions for temperature ramp-up rates for the
testing and calibrating almost any industrial process environment.
temperature instrument. • 50 °C to 660 °C temperature
• Measure RTDs, thermocouples, range
ohms, and volts to test sensors • Heat to 660 °C in 15 minutes
and transmitters • Display accuracy from
• Source/simulate thermocouples, ± 0.35 °C at 420 °C to
RTDs, volts, and ohms to cali- ± 0.5 °C at ± 660 °C
brate transmitters • Optional built-in reference
• Perform fast linearity tests with thermometer readout
25 % and 100 % steps www.flukecal.com/9144
www.fluke.com/724

Temperature Calibration 17
9100S 9102S 9103/9140/9141

Field Temperature Sources


Portable and flexible temperature-controlled dry-wells
suitable for high-speed calibrations or certifications of
thermocouples, RTDs, PRTs and other temperature sensors

9100S Handheld Dry-Well 9140 Field Dry-Well


World’s smallest, lightest and Lightweight and portable field
most portable dry-well. dry-well small enough to easily
• Smallest dry-wells in the world carry in one hand.
• Ranges from 35 °C to 375 °C • 35 °C to 350 °C
• Accuracy to ± 0.25 °C, stability • Accuracy to ± 0.5 °C
of ± 0.07 °C at 50 °C • Stability to ± 0.03 °C at 50 °C
9009
www.flukecal.com/9100S and ± 0.05 °C at 350 °C
www.flukecal.com/9140
9102S Handheld Dry-Well
High-performance, convenient and 9141 Field Dry-Well
easy-to-use handheld dry-well. Ultra-fast heat and cool times
• Smallest dry-wells in the world increase productivity.
• Ranges from –10 °C to 122 °C • 50 °C to 650 °C
• Accuracy to ± 0.25 °C, stability • Accuracy to ± 0.5 °C to 400 °C;
of ± 0.05 °C (full range) ± 1.0 °C to 650 °C
www.flukecal.com/9102S • Heats up to 650 °C in only
12 minutes
9009 Dual-Well Dry-Well www.flukecal.com/9141
Two-in-one dry-well increases
9190A portability and productivity. 9190A Ultra-Cool Field
• Temperatures from –15 °C to Metrology Well
350 °C in one unit
Very low temperatures, with no
• Display accuracy: hot block:
fluids and best-in-class stability
± 0.6 °C; cold block: ±0.2 °C
• Wide temperature range from
• Rugged, lightweight, water
–95 °C to 140 °C
resistant enclosure
• Best-in-class stability:
www.flukecal.com/9009 ± 0.015 °C full range
• Accuracy using built-in refer-
9103 Field Dry-Well ence thermometer readout:
± 0.05 °C full range
Great performance in a portable
• Display accuracy: ± 0.2 °C
instrument.
full range
• –25 °C to 140 °C
• Optional built-in two-channel
• Accuracy to ± 0.25 °C
readout for PRT, RTC, TC, 4-20
• Stable to ± 0.02 °C at –25 °C
mA and reference thermometer
and ± 0.04 °C at 140 °C
www.flukecal.com/9190A
www.flukecal.com/9103

18 Temperature Calibration
9150 6102/7102/7103 9170/9171/9172/9173

9150 Thermocouple Furnace Infrared


Convenient, portable Temperature
thermocouple furnace. Sources
• 150 °C to 1200 °C
Bench and field precision
• Stability of ± 0.5 °C over full
infrared calibrators
range
• NIST-traceable calibration for accurate and
included reliable calibrations of
• RS-232 port standard IR thermometers.
4180/4181
www.flukecal.com/9150
4180/4181 Precision
6102/7102/7103 Infrared Calibrators
Micro-Baths Accredited performance for point
Calibrate a variety of probe diam- and shoot calibrations.
eters—no sleeves required. • Calibrated radiometrically for
• Three models covering tem- meaningful, consistent results
peratures from –30 °C to 200 °C • Accredited calibration included
• World’s smallest portable • Accurate, reliable performance
calibration baths from –15 °C to 500 °C
• Stability to ± 0.015 °C • Large 152 mm (6 in) diameter 9132
www.flukecal.com/micro-baths target
www.flukecal.com/418X

9170/9171/9172/9173
Metrology Wells 9132/9133 Field
Best possible accuracy in a Infrared Calibrators
dry-block calibrator Precision when you need it for
• Best performing industrial tem- infrared temperature calibration.
perature sources in the world • Verify IR pyrometers from
(stability as good as ±0.005 °C) –30 °C to 500 °C
• Immersion depth to 203 mm (–22 °F to 932 °F)
(8 in) • RTD reference well for contact 9133
• Optional built-in readout reads temperature measurement
reference PRTs to ± 0.006 °C www.flukecal.com/913X
• Ranges:
- 9170: –45 °C to 140 °C
- 9171: –30 °C to 155 °C
- 9172: 35 °C to 425 °C
- 9173: 50 °C to 700 °C
www.flukecal.com/917X

Temperature Calibration 19
Thermometer 1586A Super-DAQ Precision
Standards Temperature Scanner
Delivering exceptional The 1586A Super-DAQ provides
accuracy, wide measurement multi-channel data acquisition for
range, and designed to voltage, resistance, and current,
go where you work. with category leading tempera-
ture measurement accuracy.
• Measure thermocouples, PRTs,
1551A Ex/1552A Ex “Stik” thermistors, dc voltage, dc cur-
Thermometer rent, and resistance
1551A Ex/1552A Ex The best substitute for • Excellent temperature measure-
precision mercury-filled ment accuracy:
glass thermometers. - PRTs: ± 0.005 °C (using exter-
• Accuracy of ± 0.05 °C nal DAQ-STAQ Multiplexer
(± 0.09 °F) over full range - Thermocouples (using High-
• Intrinsically safe (ATEX and Capacity Module w/int. CJC):
IECEx compliant) ± 0.5 °C
• Two models to choose from - Thermistors: ± 0.002 °C
(-50 °C to 160 °C or -80 °C to • Up to 40 isolated input channels
300 °C) • Selectable scan speeds: Maxi-
www.flukecal.com/155X
mum of 10 channels per second
• On-board calibration routines
control Fluke dry-wells and
1523/1524 Handheld baths for automated sensor
Thermometer Readout calibration.
1523/1524 Measure, graph and record three www.flukecal.com/1586A
sensor types with one tool.
• High accuracy: PRTs:
± 0.011 °C; Thermocouples: Ambient Conditions
± 0.24 °C; Thermistors: Monitor
± 0.002 °C For precise measurement
• A simple user interface to see and recording of ambient
trends quickly temperature and humidity
• Smart connectors to load probe conditions wherever
information automatically calibrations take place.
www.flukecal.com/152X

1620A Precision
1502A/1504 1502A/1504 Thermometer Thermo-Hygrometer
Readouts The most accurate temperature
Best performance thermometers in and humidity graphical data
their price range. logger on the market.
• Single-channel reference • Superior accuracy
thermometers, accurate to • Network enabled
±0.006 °C (meter only) • Powerful logging and
• Two models to choose from— analysis tools
reading PRTs or thermistors • Measures temperature to
• Best price/performance package ± 0.125 °C and humidity to
www.flukecal.com/150X ± 1.5 % on two channels
www.flukecal.com/1620A

1529 1529 Four-Channel


Thermometer Readout
Lab-quality accuracy on four
channels for PRTs, thermistors
and thermocouples.
• Accuracy of ±0.0025 °C
(meter only)
• Displays eight user-selected
data fields from any channel
• Logs up to 8,000 readings with
date and time stamps
www.flukecal.com/1529
1586A 1620A

20 Temperature Calibration
Precision PRTs 5618B Small Diameter
High accuracy reference Industrial RTD
temperature measurements Fast response for time-dependent
in temperature sources on measurements.
the bench or in the field. • Small diameter sheath, 3.2 mm
(0.125 in)
5627A Precision • Excellent stability
• Includes ITS-90 coefficients
Industrial PRT
www.flukecal.com/5618B
5627A 5615 • Vibration and shock resistant
• NVLAP-accredited calibration
included, lab code 200706-0 5606 Full Immersion PRT
• Calibration accuracy of Fully immerse PRT transition
± 0.046 °C at 0 °C junction inside freezers or
• Available with a 90° bend furnaces.
www.flukecal.com/5627 • Transition junction designed
to withstand full temperature
range of probe
5615 Secondary Reference • -200 °C to 160 °C
5608/5609/5609-BND Temperature Standards • Calibration accuracy of
• –200 °C to 420 °C ± 0.05 °C (full range)
• Calibrated accuracy ± 0.010 °C www.flukecal.com/5606
at 0 °C
• NVLAP-accredited calibration
included, lab code 200706-0 Thermistors
Providing accurate and
www.flukecal.com/5615
rugged temperature
measurements from
5608/5609/5609-BND 0 °C to 100 °C.
5622 5618B Secondary Reference PRTs
Drift rate of ± 0.01 °C at 0 °C after 5610/5611/5611T
100 hours at max temperature. Secondary Reference
• 5608: –200 °C to 500 °C
(80 mm minimum immersion)
Thermistor Probes
• 5609: –200 °C to 670 °C Economical lab-grade therm-
(100 mm minimum immersion) istor probes with low drift
• Optional, NVLAP-accredited susceptibility.
calibration, lab code 200348-0 • Short-term accuracy to
www.flukecal.com/5608
± 0.01 °C; one-year drift
5606/5607 < ± 0.01 °C
• 5610: 3.2 mm diameter stain-
5622 Fast Response PRTs less steel sheathed thermistor
• T ime constants as fast as • 5611: 1.5 mm diameter (tip)
0.4 seconds silicone coated thermistor
• Available as DIN/IEC Class A • 5611T: 3 mm diameter (tip)
PRTs or with NVLAP-accredited PTFE encapsulated thermistor
calibration, lab code 200348-0 • Optional, NVLAP-accredited
• Small probe diameters ranging calibration
from 0.5 mm to 3.2 mm (four www.flukecal.com/5610
models available)
www.flukecal.com/5622
5610 5611

5611T

Temperature Calibration 21
Software/
Accessories

22 Software/Accessories
Software

750 SW DPC/TRACK2 MET/TEAM® Test Equipment


Software™ Asset Management Software
DPC/TRACK2 Software is a Manage more workload with
specialized calibration manage- less work.
ment database that can help you • Browser-based calibration asset
manage your instrumentation management software
and address the documentation • Fully integrated with MET/CAL®
requirements of quality programs Software
and regulations. With DPC/TRACK2 • Microsoft SQL Server database
and a 754 DPC you can: • Highly customizable 700HTP-2
• Manage your inventory of tags • Email automation
and instruments, schedule for • On-site calibration
calibration www.flukecal.com/METTEAM
• Create tag specific procedures
with instructions and comment Accessories
• Load those procedures to your
DPC, and later upload the
results to your PC 700HTP-2 Hydraulic
• Select and execute automated Test Pump
as found/as left procedures in The 700HTP-2 is designed
the field, automatically captur- to generate pressures up to
ing results 10,000 psi/700 bar. Use the 700PTP-1
• Examine the calibration Fluke 700PRV-1 adjustable relief
histories of your tags and valves to limit pressures from
instruments and print reports 1360 psi to 5450 psi. Use the
• Import and export instrument 700HTH-1 test hose to connect
data and procedures as ASCII from the pump to the device
text under test.
• Import legacy DPC/TRACK data www.fluke.com/process_acc
www.fluke.com/750DPCsoftware

700PTP-1 Pneumatic
700G/Track Test Pump
Easy-to-use software for managing
The 700PTP-1 is a handheld
instruments and calibration data.
pressure pump designed to 700LTP-1
• Enables data download and
generate either vacuum to
logging configurations to
-11.6 psi/-0.8 bar or pressure
the 700G Series gauges for a
to 600 psi/40 bar.
remote logging event
• Configure logging event reading www.fluke.com/process_acc
rate, duration and measurement
units 700LTP-1 Low Pressure
• Upload measurements logged Test Pump
remotely and display or export
Hand operated pressure pump
measurements
designed to generate either
www.fluke.com/700Gsoftware vacuum to -13 psi/-.90 bar or
pressures to 100 psi/6.9 bar. Ideal
LogWare for low pressure applications
requiring accurate low pressure
Turn a Fluke Calibration single- testing.
channel handheld or 1502A/1504
www.fluke.com/process_acc
readout into a real-time data
logger.
• Collects realtime data
• Calculates statistics and
displays customizable graphs
• Allows user-selected start
times, stop times and sample
intervals
www.flukecal.com/logware

Software/Accessories 23
Fluke. The Most Trusted Tools in the World.
Fluke Corporation Fluke Europe B.V.
PO Box 9090, PO Box 1186, 5602 BD
Everett, WA 98206 U.S.A. Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or Fax (905) 890-6866
From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2012-2014 Fluke Corporation. Specifications subject to change without notice.
Printed in U.S.A. 2/2014 4181108C_EN

Modification of this document is not permitted without written permission from


Fluke Corporation.

Das könnte Ihnen auch gefallen