VeriFire® Tools
Programming and Test Utility

Peripheral Devices

General
VeriFire® Tools is a programming and test utility with offline
and online capabilities that can greatly reduce installation pro-
gramming time and increase confidence in the site-specific
software. It is Windows® based and provides technologically
advanced capabilities to aid the installer. The installer may cre-
ate the entire program for the control panel in the comfort of
the office, test it, store a backup file, then bring it to the site
and download from a laptop into the panel.
The program includes error checks for common programming
mistakes, such as an input point that does not activate any out-

6871prog.jpg
puts, or an output point that is not linked to any inputs. In
online mode, users can perform point “read status” functions,
edit panel and device labels, and change detector sensitivities.
VeriFire® Tools includes a compare database routine that can VeriFire® Tools System Programming Screen
also greatly help the installer. When a new program is created,
it may be compared with a previous version and differences
are highlighted. If the program is modified from the panel key-
VeriFire Tools: Available for download on the manufacturer’s
pad, it may be uploaded into VeriFire® Tools, and compared
website.
with the previous version stored on disk. The identification of
program differences greatly helps the installer in testing the 75554: DB9-NUP Programming Cable
installation. 75672: USB A type to USB B type Programming Cable
Autoprogramming: After SLC loops are installed on an ONYX
series panel, VeriFire® Tools can autoprogram that panel. The Minimum System Requirements
system will read & set addresses for SLC detectors and mod-
ules. The installer can quickly verify these with the program- • Windows® 2000 with SP4, Windows® XP Professional with
ming spreadsheet. SP2, or Windows® Vista Business/Ultimate edition
CBE Simulator: VeriFire® Tools also offers a simulator that • For Windows® 2000/Windows® XP Professional systems:
provides a visual representation of the CBE programming for – PC or laptop with a 300 MHz Pentium® II processor
any ONYX series panel. After detectors and modules have – 128MB RAM (256MB suggested)
been programmed, the simulator allows users to select any • For Windows® Vista Business/Ultimate systems:
input point and view the output points mapped to it via CBE
programming. – A 1 GHz 32-bit (x86) processor (Note: 64-bit processor
not supported with Vista)
Device maintenance report: VeriFire® Tools has a device
– 1GB RAM
maintenance report for NFS2-3030, NFS2-640, and NFS-320
panels. The device maintenance report provides valuable • CD-ROM drive
information on FlashScan detectors; chamber values, the per- • Mouse and keyboard
cent of drift compensation and last functional test date. This • 250 MB free disk space (600 MB recommended for audio
information is extremely useful in scheduling maintenance and storage)
testing of detectors. For FlashScan modules, the maintenance
• XVGA monitor
report provides the last functional test date.
• Video card capable of supporting 1024 x 768 output resolu-
Network test service: VeriFire® Tools can run a communica- tion and 16 bit color
tion test between selected network nodes, to verify network
connectivity. It sends messages from one node to another and • 1 serial (COM) port or USB-to-Serial converter (ATEN
monitors the resulting node-to-node activity to determine Model UC-232A recommended) (Use a USB A to B cable.
whether any message failures occur. The test procedure USB connection must be less than 10 feet long)
aborts if a real event occurs anywhere on the network. • DB9-NUP cable (P/N 75554) for serial connections— sup-
plied with VeriFire Tools. (Serial port recommended for
NFS-3030, NFS-640, and NCA connections.)
Product Line Information
• USB A type to USB B type cable (Notifier P/N 75672) —
VeriFire-TCD: VeriFire® Tools CD-ROM and local panel pro- supplied with VeriFire Tools. (USB 2.0 port recommended
gramming cable (75554 for DB9-NUP programming and 75672 for NFS2-3030, NCA-2, NFS2-640, NFS-320, and DVC
for USB). Contains programming software for all ONYX Series connections)
panels, Digital Voice Command (DVC), and associated DAA
amplifiers. Includes audio files that can be programmed into • Microsoft® Excel 2000, 2003, or 2007 (to use the spread-
the DVC. sheet function)
• Internet connection (for IP connections and to use email
VeriFireUG-TCD: VeriFire® Tools Upgrade CD-ROM. Con- function)
tains latest version (software only).
• MAPI compatible email client, such as Microsoft® Outlook
or Microsoft® Outlook Express (to use email function)

DN-6871:C • 1/28/2010 — Page 1 of 2


NOTE: VeriFire Tools version 3.21 and earlier supported Windows
98 Second Edition, ME, and NT. Windows 95 not supported.

Digital Audio
TO PROGRAM THE DIGITAL AUDIO SYSTEM:
• USB port (for suggested USB Digital Headset used in audio
recording)
• Plantronics DSP500 Digital Enhanced USB Headset (rec-
ommended) or your PC’s sound card with any standard UL-
approved PC microphone
• Goldwave Digital Audio Editor (recommended) or equiva-
lent audio editing software
DIGITAL AUDIO FILE FORMAT DESCRIPTIONS
Audio editing software must be able to save files to .wav format
with the following descriptions:

Fidelity High Quality Standard Quality


Format PCM µlaw
Sample Rate 44100Hz 11025Hz
Bit Depth 16-bit 8-bit
Channel mono mono

VeriFire® and ONYX® are registered trademarks of Honeywell International


Inc. Microsoft® and Windows® are registered trademarks of Microsoft
Corporation. Pentium® and Intel® are registered trademarks of Intel
Corporation.
©2010 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.

This document is not intended to be used for installation purposes.


We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
Made in the U.S. A.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
www.notifier.com