Beruflich Dokumente
Kultur Dokumente
2
Applications NBG, NBGE, NKG, NKGE
Introduction
NBG and NKG are multi-purpose pumps suitable for a
variety of different applications demanding reliable and
cost-efficient supply.
NBG and NKG pumps are used in five main fields of
application:
Water supply
Besides general water supply in municipal and indus-
trial waterworks, the NBG and NKG pumps are used for
these specific applications:
• filtration and transfer at waterworks
• pressure boosting in mains
HVAC
Liquid transfer in:
• heating systems
TM03 0149 4204
• ventilation systems
• air-conditioning systems
Irrigation
Irrigation covers these applications:
• field irrigation (flooding)
• sprinkler irrigation
• drip-feed irrigation.
3
Features and benefits NBG, NBGE, NKG, NKGE
4
Features and benefits NBG, NBGE, NKG, NKGE
5
6
H
[m]
200
NBG/NKG
2-pole, 50 Hz
150
NBG, NKG, 2-pole
125-80-315
100-65-315
65-40-315 80-50-315
125-100-315
100
150-125-315
90
200-150-315
80 100-65-250 150-125-250
65-40-250 125-80-250
70 80-50-250
Performance range
125-100-250
60
200-150-250
50
50-32-200 65-40-200 80-50-200 100-65-200 125-80-200
125-100-200
40
150-125-200
200-150-200
20
125-100-160
15
10 15 20 30 40 50 60 80 100 150 200 300 400 500 600 800 1000 1400
Q [m³/h]
70
60
125-80-400
50
150-125-400 200-150-400
40
125-80-315
150-125-315
20
65-40-250 80-50-250 100-65-250 125-80-250 125-100-250 150-125-250
15
200-150-250
10
8 200-150-200
50-32-160 65-50-160 80-65-160 100-80-160
7
125-80-160
6
125-100-160
150-125-200
5
4
10 15 20 30 40 50 60 80 100 150 200 300 400 500 600 800 1000
Q [m³/h]
7
Product range NBG, NBGE, NKG, NKGE
8
Product range NBG, NBGE, NKG, NKGE
E-motors (NBG/NKG)
E-motors (NBG/NKG)
Pump type Pump type
NBG design
NBG design
NKG model
NKG model
PN 16
PN 16
A z z 2.2 C z z z z 11
A z z 3 C z z z z 15
50-32-160 B C z z z z 18.5
A z z 4 100-65-200 B
A z z 5.5 C z z z z 22
A z z 4 C z z z 30
A z z 5.5 C z z z 37
50-32-200 B C z z z 30
A z z 7.5
A z z 11 C z z z 37
A z z z z 4 100-65-250 B C z z z z 45
A z z z z 5.5 C z z z 55
65-50-160 B C z z 75
A z z z z 7.5
C z z z z 11 C z z z z 55
A z z z z 5.5 C z z z z 75
100-65-315 B
A z z z z 7.5 C z z z z 90
65-40-200 B C z z z z 110
C z z z z 11
C z z z z 15 C z z z z 11
C z z z z 11 C z z z z 15
C z z z z 15 125-80-160 B C z z z z 18.5
65-40-250 B C z z z z 18.5 C z z z z 22
C z z z z 22 C z z z 30
C z z z 30 C z z z z 22
C z z z z 22 C z z z 30
C z z z 30 125-80-200 B C z z z 37
65-40-315 B C z z z z 45
C z z z 37
C z z z z 45 C z z z z 55
A z z z z 5.5 C z z z z 45
A z z z z 7.5 C z z z z 55
80-65-160 B 125-80-250 B
C z z z z 11 C z z z 75
C z z z z 15 C z z 90
C z z z z 11 C z z z z 90
C z z z z 15 C z z z z 110
80-50-200 B 125-80-315 B
C z z z z 18.5 C z z z z 132
C z z 22 C z z z 160
C z z z z 15 C z z 22
C z z z z 18.5 125-100-160 B C z 30
80-50-250 B C z z z z 22 C z 37
C z z z 30 C z 30
C z z z 37 C z 37
C z z z 30 125-100-200 B C z z 45
C z z z 37 C z z 55
80-50-315 B C z z 75
C z z z z 45
C z z z z 55 C z z 55
A z z z z 7.5 C z z 75
C z z z z 11 125-100-250 B C z z 90
100-80-160 B C z z 110
C z z z z 15
C z z z z 18.5 C z z 132
9
Product range NBG, NBGE, NKG, NKGE
Pressure P2
Optional
stage [kW]
E-motors (NBG/NKG)
Pump type
PN 16
C z z 110
C z z 132
125-100-315 B
C z z 160
C z z 200
C z z 45
C z z 55
150-125-200 B C z z 75
C z z 90
C z z 110
C z z 90
C z z 110
150-125-250 B C z z 132
C z z 160
C z z 200
C z z 132
150-125-315 B C z z 160
C z z 200
C z z 75
200-150-200 B C z z 90
C z z 110
C z z 132
C z z 160
200-150-250 B
C z z 200
- z 250
- z 250
200-150-315 B - z 315
- z 355
10
Product range NBG, NBGE, NKG, NKGE
E-motors (NBG/NKG)
E-motors (NBG/NKG)
Pump type Pump type
NBG design
NBG design
NKG model
NKG model
PN 16
PN 16
A z 0.55 A z z z z 5.5
50-32-160 B A z z z z 7.5
A z z 0.75 100-65-315 B
A z 0.55 C z z z z 11
A z z 0.75 C z z z z 15
50-32-200 B A z z z z 1.5
A z z 1.1
A z z 1.5 A z z z z 2.2
125-80-160 B
A z z z 0.55 A z z z z 3
65-50-160 B A z z z z 0.75 A z z z z 4
A z z z z 1.1 A z z z z 2.2
A z z z z 0.75 A z z z z 3
A z z z z 1.1 125-80-200 B A z z z z 4
65-40-200 B A z z z z 5.5
A z z z z 1.5
A z z z z 2.2 A z z z z 7.5
A z z z z 1.5 A z z z z 5.5
65-40-250 B A z z z z 2.2 125-80-250 B A z z z z 7.5
A z z z z 3 C z z z z 11
A z z z z 3 C z z z z 11
A z z z z 4 C z z z z 15
65-40-315 B 125-80-315 B
A z z z z 5.5 C z z z z 18.5
A z z z z 7.5 C z z z z 22
A z z z z 0.55 C z z z z 18.5
A z z z z 0.75 C z z z z 22
80-65-160 B A z z z z 1.1 125-80-400 B C z z z 30
A z z z z 1.5 C z z z z 37
A z z z z 2.2 C z z z z 45
A z z z z 1.1 A z z 2.2
A z z z z 1.5 125-100-160 B A z z 3
80-50-200 B A z z 4
A z z z z 2.2
A z z z z 3 A z z 4
A z z z z 2.2 A z z 5.5
125-100-200 B
80-50-250 B A z z z z 3 A z z 7.5
A z z z z 4 C z z 11
A z z z z 4 A z z 7.5
A z z z z 5.5 C z z 11
80-50-315 B 125-100-250 B
A z z z z 7.5 C z z 15
C z z z z 11 C z z 18.5
A z z z z 0.75 C z z 15
A z z z z 1.1 C z z 18.5
100-80-160 B 125-100-315 B
A z z z z 1.5 C z z 22
A z z z z 2.2 C z 30
A z z z z 1.5 C z z 22
A z z z z 2.2 C z 30
100-65-200 B 125-100-400 B C z z 37
A z z z z 3
A z z z z 4 C z z 45
A z z z z 3 C z z 55
A z z z z 4
100-65-250 B
A z z z z 5.5
A z z z z 7.5
11
Product range NBG, NBGE, NKG, NKGE
Pressure P2
Optional
stage [kW]
E-motors (NBG/NKG)
Pump type
PN 16
A z z 5.5
A z z 7.5
150-125-200 B
C z z 11
C z z 15
C z z 11
C z z 15
150-125-250 B C z z 18.5
C z z 22
C z 30
C z z 18.5
C z z 22
150-125-315 B C z 30
C z z 37
C z z 45
C z z 37
C z z 45
150-125-400 B C z z 55
C z z 75
C z z 90
C z z 55
C z z 75
C z z 90
150-125-500 B
C z z 110
C z z 132
C z z 160
A z z 7.5
200-150-200 B C z z 11
C z z 15
C z z 15
C z z 18.5
C z z 22
200-150-250 B
C z 30
C z z 37
C z z 45
C z z 37
C z z 45
200-150-315 B C z z 55
C z z 75
C z z 90
C z z 55
C z z 75
C z z 90
200-150-400 B
C z z 110
C z z 132
C z z 160
C z z 132
C z z 160
200-150-500 B C z z 200
- z 250
- z 315
12
Identification NBG, NBGE, NKG, NKGE
Example NBG 50-32 -160 /177 A -F -A -BQQE Example NKG 50-32 -160 /177 A1 -F -A -BQQE
Type range Type range
Nominal diameter of suction and Nominal diameter of suction and
discharge port (DN) discharge port (DN)
Nominal impeller diameter [mm] Nominal impeller diameter [mm]
Actual impeller diameter [mm] Actual impeller diameter [mm]
Code for pump version (the codes may be combined) Code for pump version (the codes may be combined)
A = Basic version A1 = Basic version with standard coupling
B = Oversize motor A2 = Basic version with spacer coupling
C = Without motor AH = Bare shaft pump
D = Pump housing with feet C = Without motor
E = With ATEX approval, certificate or test report E = With ATEX approval, certificate or test report
F = Design with base frame X = Special version
X = Special version
Code for pipework connection:
Code for pipework connection: E = Table E flange (AS 2129, table E)
E = Table E flange (AS 2129, table E)
Code for materials:
Code for materials: A = EN-GJL-250 pump housing, EN-GJL-200 impeller and
A = EN-GJL-250 pump housing, EN-GJL-200 impeller and bronze wear ring
bronze wear ring B = EN-GJL-250 pump housing and bronze CuSn10
B = EN-GJL-250 pump housing and bronze CuSn10 impeller, bronze wear ring
impeller, bronze wear ring C = As type A + 1.4401shaft
C = As type A + 1.4401shaft D = As type B + 1.4401shaft
D = As type B + 1.4401shaft S = EN-GJL-250 pump housing and 1.4408 impeller, bronze
S = EN-GJL-250 pump housing and 1.4408 impeller, bronze wear ring
wear ring N = 1.4408 pump housing and impeller, PTFE wear ring
N = 1.4408 pump housing and impeller, PTFE wear ring R = 1.4517 pump housing and impeller, PTFE wear ring
R = 1.4517 pump housing and impeller, PTFE wear ring P = 1.4408 pump housing, 1.4517 impeller, PTFE wear ring
P = 1.4408 pump housing, 1.4517 impeller, PTFE wear ring K = 1.4408 pump housing and impeller, 1.4517 wear ring
K = 1.4408 pump housing and impeller, 1.4517 wear ring L = 1.4517 pump housing, impeller and wear ring
L = 1.4517 pump housing, impeller and wear ring M = 1.4408 pump housing, 1.4517 impeller and wear ring
M = 1.4408 pump housing, 1.4517 impeller and wear ring X = Special version
X = Special version
Code for mechanical shaft seal and rubber pump parts
Code for mechanical shaft seal and rubber pump parts
13
Identification NBG, NBGE, NKG, NKGE
Shaft seals
NBG and NKG pumps are available with a BQQE shaft
seal as standard. Other shaft seal variants are available
on request.
14
Construction NBG, NBGE, NKG, NKGE
Detail A
Stub shaft
15
Construction NBG, NBGE, NKG, NKGE
Detail A
16
Construction NBG, NBGE, NKG, NKGE
Detail A
17
Construction NBG, NBGE, NKG, NKGE
Detail A
18
Construction NBG, NBGE, NKG, NKGE
19
Construction NBG, NBGE, NKG, NKGE
Shaft (NBG)
The stainless steel shaft is ∅28, ∅38, ∅48, ∅55 or Fig. 12 Standard coupling
∅60, where the shaft seal is mounted.
The coupling end of the shaft is cylindrical and has two
drilled holes for the set screws of the coupling.
TM02 9500 2704
Fig. 14 Impeller
All impellers are statically and hydraulically balanced.
The hydraulic balancing compensates for axial thrust.
The direction of rotation of the impeller is clockwise
when viewed from the motor.
For pumps with motor sizes 30 kW and larger, impellers
can be adapted to the duty point as requested by the
customer.
20
Construction NBG, NBGE, NKG, NKGE
Motor range
Fig. 15 Schematic view of NKG pump-motor unit mounted
on a base frame Efficiencies according to MEPS 2
Output P 2 [kW] 2-pole 4-pole
A base frame prepared for grouting is available as an 0.25
option, see "Foundation (NKG)" on page 26. 0.37
MG model C
0.55
Surface treatment 0.75 MG model C
1.1
NBG and NKG 1.5
2.2 MG model D
The cast-iron parts of NBG and NKG have an epoxy-
3 MG model D
based coating made in a cathodic electro-deposition
4
(CED) process. CED is a high-quality dip-painting 5.5
process where an electrical field around the products 7.5
ensures deposition of paint particles as a thin, well- 11
controlled layer on the surface. An integral part of the 15
process is a pretreatment. The entire process consists 18.5
22
of these elements:
30
1. Alkaline-based cleaning. 37
2. Zinc phosphating. 45
MMG model G
55
3. Cathodic electro-deposition. 75 MMG model G
4. Curing to a dry film thickness 18-22 μm. 90
The colour code for the finished product is 110
132
NCS 9000/RAL 9005.
160
For low-temperature applications at high humidity 200
Grundfos offers NBG and NKG pumps with extra sur- 250
315
face treatment to avoid corrosion. These pumps are
355
available on request.
E-motor range
Test pressure Electronically speed-controlled motors
Pressure testing was made with +20 °C water contain- Output P 2 [kW] 2-pole 4-pole
ing corrosion inhibitor. 0.75
1.1
Pressure Operating pressure Test pressure 1.5
stage bar MPa bar MPa 2.2
PN 16 16 1.6 24 2.4 3
4 MGE
5.5
MGE
7.5
11
15
18.5
22
21
Operating conditions NBG, NBGE, NKG, NKGE
Pump location P2
The pump is designed for installation in a non-aggres- [%]
sive and non-explosive atmosphere. 100
EFF 1
90
The relative air humidity must not exceed 95 %.
80 EFF 2
70
Ambient temperature must not exceed: • The head, flow rate and pump efficiency will remain
unchanged.
• + 60 °C for EFF1 motors.
• The power consumption will increase at a ratio cor-
If the ambient temperature exceeds + 60°C or if the responding to the increase in density. A liquid with a
motor is installed more than 1000 m (3500 feet) above specific gravity of 1.2 will thus require a 20 % larger
sea level, the motor must not be fully loaded due to the power input.
low density and consequently low cooling effect of the • An oversize motor will often be required.
air. In such cases, it may be necessary to use a motor WinCAPS can help you select the right pump for liquids
with a higher output. with viscosity/density different from those of water.
22
Operating conditions NBG, NBGE, NKG, NKGE
Liquid temperatures
The NBG and NKG pump range covers the temperature
range from –25 °C to +140 °C. The permissible liquid
temperature depends on the mechanical shaft seal type
and pump type. See also the table below.
Be aware that the maximum liquid temperature limits
stated by Grundfos may be overruled by local regula-
tions and various laws.
The maximum liquid temperature is stamped on the
nameplate.
*) Max. 60 °C
Carbon/silicon carbide
Mechanical shaft seals with carbon/silicon carbide
(xAQx) seal faces have a wide range of applications
and are especially suitable if there is risk of dry running
and/or if the temperature is high. These mechanical
shaft seals are not suitable for liquids containing abra-
sive particles as the carbon parts will be worn. At tem-
peratures below 0 °C, corrosion inhibitors containing
abrasive particles will usually be added to the pumped
liquid, and xAQx seals will thus not be suitable.
23
Operating conditions NBG, NBGE, NKG, NKGE
Ø650
[mm]
600
550
500
450
CuSn10
400
350
300
TM03 4109 1806
EN-GJL-200
250
200
1200 1600 2000 2400 2800 3200 3600 min-1
Inlet pressure
Maximum inlet pressure
The actual inlet pressure + pressure when the pump is
running against a closed valve must always be lower
than the maximum permissible operating pressure.
24
Operating conditions NBG, NBGE, NKG, NKGE
110 15
pb = Barometric pressure in bar. 12
100 10
(Barometric pressure can be set to 1 bar.) 8,0
90
In closed systems, pb indicates the system 6,0
80 5,0
pressure in bar. 4,0
70
NPSH = Net Positive Suction Head in metres head. 3,0
Hf
TM02 6572 1003
Pb
H NPSH • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
•• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Hv
25
Installation and operating NBG, NBGE, NKG, NKGE
315
355
26
Installation and operating NBG, NBGE, NKG, NKGE
Piping
When installing the pipes, make sure that the pump
housing is not stressed by the pipework.
The suction and discharge pipes must be of an ade-
quate size, taking the pump inlet pressure into account.
Install the pipes so that air locks are avoided, especially
on the suction side of the pump, see Fig. 26
Grout
5-10 mm
Levelling
wedges
•
•
•
•
•
•
•
•
•
•
•
or shims
19 to 32 mm
TM03 2946 4707
• • •
•
•
•
•
left in
• • •
•
•
•
• • • •
•
• • • •
• • •
•
• •
• •
•
•
• •
• •
• • •
• • •
• • •
•
• •
• • • • •
•
• • •
•
• • • •
grout
•
• • • •
• • •
• • •
• •
• •
• •
place
•
• • • •
•
• •
•
•
• • •
• • • •
• •
• • •
•
• •
• • •
• •
• • •
• •
• •
•
• •
•
• • •
• • •
•
• • •
•
• • •
• •
• • •
• • •
•
•
•
•
• • • •
•
• • •
•
• •
• •
• •
• • • •
•
• • • • •
•
•
•
• •
•
Top of
• •
• •
• •
•
•
• •
•
• • • •
•
•
•
•
• • •
• • • •
• • •
Formwork
• •
• • •
•
•
• •
• • • •
•
• •
• • •
• •
•
• •
•
foundation
• • • • •
• •
•
•
• • • •
• • • •
• • •
• • •
• • •
• •
• •
•
• • • •
• • •
• •
• •
•
•
• •
• •
• • •
•
• •
•
• •
• • •
• • • •
• • • •
(rough)
•
• •
• • •
• • •
• •
• • •
• •
• • •
•
•
•
•
• • •
•
• • •
•
•
TM02 5679 3802
27
Installation and operating NBG, NBGE, NKG, NKGE
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Vibration damper
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
•••
••••
••••
••••
••••
••••
•••• •• ••
••••••••
••••
••••
••••
••••
•••
••••
••••
••••
••••
••••
•••• ••
••••••••
••••
••••
••••
••••
•••
••••
••••
••••
••••
••••
•••• ••
••••••••
••••
••••
••••
••••
•••
••••
••••
••••
••••
••••
•••• ••
••••••••
••••
••••
••••
••••
•••
••••
•• ••••
•• ••••
•• ••••
•• ••••
•• •••••
••
••
•• ••••
•• •• ••••
•• ••••
•• ••••
•• •••••
••
Vibration dampers
To prevent the transmission of vibrations to buildings,
we recommend you to isolate the pump foundation from
building parts by means of vibration dampers.
The selection of the right vibration damper requires the
following data:
• forces transmitted through the damper
• motor speed considering speed control, if any
• required dampening in % (suggested value is 70 %).
Which is the right damper varies from installation to
TM02 4979 1902 & TM02 4981 1902
28
Installation and operating NBG, NBGE, NKG, NKGE
Alignment
In a complete pump unit assembled and supplied from
factory, the coupling halves have been accurately aligned.
Alignment is made by inserting shims under the pump and
motor mounting surfaces as required.
The pump/motor alignment may be affected during trans-
port. Always check alignment after the pump has been
installed.
If misalignment has occurred due to radial or angular shift-
ing, realign by inserting/removing shims under the feet of
the pump or the motor.
Take care to align carefully, as this will considerably
increase the lives of the coupling, bearings and shaft seal.
Note: Check the final alignment when the pump has
obtained its operating temperature under normal operat-
ing conditions.
29
Speed-controlled pumps NBG, NBGE, NKG, NKGE
Most NBG and NKG pumps are available with motors Constant curve
with integrated speed control. These pumps are called In constant curve control mode, the pump will adjust its
NBGE and NKGE. speed to meet the required flow without using throttle
Alternatively, all NBG and NKG pumps with three- valves.
phase motors can be connected to an external fre- In this control mode the pump can be set to operate
quency converter. within 12-100 % of the maximum performance range.
A sensor is not required for this control mode.
NBGE and NKGE pump applications
NBGE and NKGE pumps with integrated speed control Constant pressure
enable automatic adaptation of performance to current In constant pressure-control mode, the pump will adjust
conditions. This keeps the energy consumption at a its speed to keep a constant pressure where the sensor
minimum. is fitted.
Depending on the nature of the application, NBGE and We recommend constant-pressure control mode in
NKGE pumps offer energy-savings, increased comfort pressure-holding systems.
or improved processing.
A pressure sensor with a suitable operating range is
The charts below show possible control modes of required.
NBGE and NKGE pumps in different applications.
Temperature control
Control mode Applications In the temperature control mode, the pump will adjust
Constant curve its speed to keep a constant temperature or a differen-
Single-pipe heating systems tial temperature.
Systems with three-way valves
We recommend this control mode in systems with
Heating and cooling surfaces
three-way valves and systems without control valves.
Chiller pumps
(Sensor not required) A temperature sensor or a differential temperature sen-
sor is required for this control mode.
Constant pressure
Example
Pressure boosting systems
In an industrial cooling system, an NKGE pump contin-
(Sensor required)
uously adapts its performance to the changing
demands reflected in the differences in temperature of
the liquid circulating in the cooling system. The lower
the demand for cooling, the smaller the quantity of liq-
uid circulated in the system and vice versa.
Temperature control
Single-pipe heating systems
Constant flow
Systems with three-way valves
In the constant-flow control mode, the pump will adjust
Cooling towers
its speed to keep a constant flow irrespective of varia-
Chiller pumps
tions of the system characteristics.
Domestic hot-water recirculation systems
(Sensor required) We recommend this control mode in systems where
Constant flow a constant flow is required.
Heating and cooling surfaces In this control mode either an electronic flowmeter or
Cooling towers a differential pressure sensor is required.
Flow filters
(Sensor required) Proportional differential pressure
(measured)
In the proportional differential pressure (measured)
Proportional differential pressure (measured) mode, the pump will adjust its speed to keep the differ-
System with two-way valves ential pressure in a reference point in the system.
(Differential pressure sensor is located in
the system) This control mode is recommended in large circulation
systems where the NBGE or NKGE pump functions as
a secondary pump. A differential pressure sensor is
required for this control mode.
30
Speed-controlled pumps NBG, NBGE, NKG, NKGE
criteria:
η
• The max. duty point required should be as close as ----n- ≈ 1
ηx
possible to the QH curve of the pump.
• The flow rate at the duty point required should be
close to the optimum efficiency (eta) for most oper-
ating hours.
Q
Between the min. and max. performance curve, NBGE
P Qx Qn
and NKGE pumps have an infinite number of perform-
ance curves each representing a specific speed. It may
therefore not be possible to select a duty point close to
Pn ⎛n ⎞ 3
Pn ------ = ⎜ -----n-⎟
the max. curve.
Px ⎝ n x⎠
H
[m]
Q
Max. curve
Fig. 32 Affinity equations
Legend
Min. curve
Hn Rated head in metres
TM01 4916 4803
31
Communication NBG, NBGE, NKG, NKGE
Control panel
The operator can change the setpoint settings manually
on the control panel of the NBGE, NKGE pump terminal
LON-bus connection
box.
Light fields
G10-LON
Interface
Operating
buttons
GENIbus connection
Fig. 33 Structure of a central building management Fig. 35 Control panel of an NBGE, NKGE pump
system
32
Selection of product NBG, NBGE, NKG, NKGE
33
Pumped liquids NBG, NBGE, NKG, NKGE
34
Pumped liquids NBG, NBGE, NKG, NKGE
Material version
Pumped liquids Notes Additional information Shaft seal
A B S N R
Water
Acidic minewater Low pH value, high chloride content x x BQQE
<120 °C x BAQE
Boiler-feed water
120 °C - 140 °C x BQBE/DAQF 1)
Brackish water a 30 °C, 2000 ppm chloride x BQQE
<90 °C x BQQE
Condensate 90 °C - 120 °C x BAQE
120 °C - 140 °C x BQBE/DAQF 1)
Cooling and cutting lubricant x BQQV
Demineralized water <90 °C x BQQE
<120 °C BAQE
District heating water
120 °C - 140 °C x BQBE/DAQF 1)
<90 °C x x x BQQE
Groundwater
>90 °C x x x BAQE 2)/BQBE
Oil containing water <90 °C x BQQV
<90 °C x x BQQE
Softened water
90 °C - 120 °C x x BAQE 2)
Seawater a <35 °C x BQQE
40 °C, 150 ppm Cl-
Swimming-pool water, chlorinated c x x BQQE
(< 2 ppm free chlorine)
Coolants
Calcium chloride b, d, e, g <5 °C, 30 % x BQQE/GQQE
Ethylene glycol b, d <50 °C x BQQE/GQQE
Glycerine (glycerol) b, d <50 °C x BQQE/GQQE
Hydrocarbon-based coolant d, f 50 °C x BQQV/GQQV
Potassium acetate (inhibited) b, d, e, g <20 °C x x x BQQE/GQQE
Potassium formate (inhibited) b, d, e, g <20 °C x x x BQQE/GQQE
Propylene glycol b, d <50 °C x BQQE/GQQE
Sodium chloride b, d, e, g <5 °C, 30 % x BQQE/GQQE
Fuels
Biodiesel f x BAQV
Diesel oil f x BAQV
Jet fuel f x BAQV
Kerosene f x BAQV
Naphta f x BAQV
Petrol f x BAQV
Mineral oils
Crude oil b, d, f <20 °C x BQQV
Mineral lubricating oil d, f x BAQV/BQQV
Mineral motor oil d, f x BAQV/BQQV
Synthetic oils
Synthetic lubricating oil d, f x BAQV/BQQV
Synthetic motor oil d, f x BAQV/BQQV
Silicone oil d x BAQV/BQQV
Vegetable oils
Corn oil b, d x x BAQV/BQQV
Olive oil b, d x x BAQV/BQQV
Peanut oil b, d x x BAQV/BQQV
Rape seed oil b, d x x BAQV/BQQV
Soya oil b, d x x BAQV/BQQV
Cleaning
Alkaline degreasing agent b, h <80 °C x x BQQE/DAQF 4)
Soap (salts of fatty acids) b <80 °C x x x BQQV
Organic solvents
Acetone f 40 °C x BAQE 3)/BBQE
Ethyl alcohol (ethanol) f 40 °C x BAQE 3)/BBQE
Hydrogen peroxide 20 °C, 5 % x BQQE
Isopropyl alcohol f 40 °C x BAQE 3)/BBQE
Methyl alcohol (methanol) f 40 °C x BAQE 3)/BBQE
35
Pumped liquids NBG, NBGE, NKG, NKGE
Material version
Pumped liquids Notes Additional information Shaft seal
A B S N R
Oxidants
Sodium hypochlorite 20 °C, 0.1 % x BQQV
Salts
20 °C, 15 % x BQQE
Ammonium bicarbonate b, d
60 °C, 20 % x BQQE
Copper sulphate b, d, g 60 °C, 20 % x x BQQE
Ferric sulphate b, d, g 20 °C, 20 % x x BQQE
20 °C, 20 % x BQQE
Potassium bicarbonate b, d
60 °C, 20 % x BQQE
20 °C, 20 % x BQQE
Sodium carbonate b, d, g
60 °C, 20 % x BQQE
20 °C, 1 % x BQQE
Potassium permanganate b, d
50 °C, 10 % x BQQE
20 °C, 5 % x BQQE
Sodium nitrate b, d
60 °C, 20 % x BQQE
20 °C, 20 % x BQQE
Sodium nitrite b, d
60 °C, 20 % x BQQE
Sodium phosphate (mono) b, d 60 °C, 20 % x BQQE
30 °C, 20 % x BQQE
Sodium phosphate (di) b, d
60 °C, 20 % x BQQE
20 °C, 10 % x BQQE
Sodium phosphate (tri) b, d, g
70 °C, 20 % x BQQE
Sodium sulphate b, d, g 60 °C, 20 % x BQQE
20 °C, 1 % x BQQE
Sodium sulphite b, d, g
60 °C, 20 % x BQQE
Acids
Acetic acid 20 °C, 15 % x BQQE
Chromic acid 20 °C, 10 % x BQQE
Citric acid d 50 °C, 20 % x BQQE
Formic acid d 20 °C, 30 % x BQQE
Nitric acid d 20 °C, 40 % x BQQE
Oxalic acid g 20 °C, 10 % x BQQE
Phosphoric acid b, d, g 70 °C, 40 % x BQQE
Sulphuric acid b, d 20 °C, 20 % x BQQV
Sulphurous acid 20 °C, 5 % x BQQV
Alkalies
Ammonium hydroxide 30 °C, 30 % x BQQE
Calcium hydroxide b 30 °C, 5 % x BQQE
20 °C, 20 % x BQQE
Potassium hydroxide d, g
60 °C, 20 % x BQQE
20 °C, 20 % x BQQE
Sodium hydroxide d, g
80 °C, 20 % x BQQE
1) Shaft diameters measured at the shaft end (d5) are either 24, 32, 42, 48 or 60 mm. BQBE shaft seals can be used for shaft end diameter (d5) 24 or 32 mm.
DAQF shaft seals can be used for all five shaft diameters.
2) Do not use BAQE for potable water. For potable water, we recommend BBQE shaft seals.
3) If diluted with water, use BBQE.
4) If oil residuals are present, use DAQF.
36
Electrical data NBG, NBGE, NKG, NKGE
The tables below give all electrical data for motors for
NBG(E) and NKG(E) pumps.
37
Electrical data NBG, NBGE, NKG, NKGE
P2 I1/1
Motor Frame size Voltage
[kW] [A]
MGE 90SB-D 1.5 3.3 - 2.7
MGE 90LC-D 2.2 4.6 - 3.8
MGE 100LC-D 3 6.2 - 5.0
MGE 112MC-D 4 8.1 - 6.6
MGE 132SC-D 5.5 11.0 - 8.8
3 x 380-480 V
MGE 132SB-F 7.5 14.8-11.6
MGE 160MB-F 11 22.5-18.8
MGE 160MD-F 15 30.0-26.0
MGE 160LB-F 18.5 37.0-31.0
MGE 180MB-F 22 43.5-35.0
P2 I1/1
Motor Frame size Voltage
[kW] [A]
MGE 90SA-D 0.75 1.8-1.9
MGE 90SB-D 1.1 2.5 - 2.2
MGE 90LC-D 1.5 3.3 - 2.9
MGE 100LB-D 2.2 4.6 - 3.8
MGE 112LC-D 3 6.2 - 5.0
MGE 112MC-D 3 x 380-480 V 4 8.1 - 6.6
MGE 132SB-F 5.5 11.0-9.0
MGE 132MB-F 7.5 15.0-12.0
MGE 160MB-F 11 22.0-17.8
MGE 160LB-F 15 30.0-25.4
MGE 180MA-F 18.5 37.0-30.0
38
NKG bare shaft pumps NBG, NBGE, NKG, NKGE
NKG model B
a f x DN t M
l
h2
d5
n
DN s
h1
c
S1
w
n1
Weight
Pump [mm] Supporting feet [mm] Shaft [mm]
Type [kg]
DNs DNt a f h1 h2 M b m1 m2 n1 n2 n3 w S1 S2 c d5 l x t n CI(1 SS(2
NKG 50-32-160 50 32 80 385 132 160 3/8” 50 100 70 240 190 110 285 M12 M12 18 24 50 100 27 8 46 -
NKG 50-32-200 50 32 80 385 160 180 3/8” 50 100 70 240 190 110 285 M12 M12 18 24 50 100 27 8 54 -
NKG 65-50-160 65 50 80 385 132 160 3/8” 50 100 70 240 190 110 285 M12 M12 18 24 50 100 27 8 48 48
NKG 65-40-200 65 40 100 385 160 180 3/8” 50 100 70 265 212 110 285 M12 M12 18 24 50 100 27 8 55 57
NKG 65-40-250 65 40 100 500 180 225 3/8” 65 125 95 320 250 110 370 M12 M12 19 32 80 100 35 8 81 85
NKG 65-40-315 65 40 125 500 200 250 3/8” 65 125 95 345 280 110 370 M12 M12 24 32 80 100 35 8 124 116
NKG 80-65-160 80 65 100 385 160 180 3/8” 50 100 70 265 212 110 385 M12 M12 18 24 50 100 27 8 52 54
NKG 80-50-200 80 50 100 385 160 200 3/8” 50 100 70 265 212 110 385 M12 M12 18 24 50 100 27 8 58 59
NKG 80-50-250 80 50 125 500 180 225 3/8” 65 125 95 320 250 110 370 M12 M12 19 32 80 100 35 8 86 88
NKG 80-50-315 80 50 125 500 225 280 1/2” 65 125 95 345 280 110 370 M12 M12 31 32 80 100 35 8 130 119
NKG 100-80-160 100 80 100 500 160 200 3/8” 65 125 95 280 212 110 370 M12 M12 19 32 80 100 35 8 72 71
NKG 100-65-200 100 65 100 500 180 225 3/8” 65 125 95 320 250 110 370 M12 M12 19 32 80 140 35 8 81 82
NKG 100-65-250 100 65 125 500 200 250 1/2” 80 160 120 360 280 110 370 M16 M12 23 32 80 140 35 10 111 110
NKG 100-65-315 100 65 125 530 225 280 3/8” 80 160 120 400 315 110 370 M16 M12 23 42 110 140 45 10 141 145
NKG 125-80-160 125 80 125 500 180 225 3/8” 65 125 95 320 250 110 370 M12 M12 19 32 80 140 35 8 81 83
NKG 125-80-200 125 80 125 500 180 250 3/8” 65 125 95 345 280 110 370 M12 M12 19 32 80 140 35 8 95 100
NKG 125-80-250 125 80 125 500 225 280 3/8” 80 160 120 400 315 110 370 M16 M12 23 32 80 140 35 10 115 119
NKG 125-80-315 125 80 125 530 250 315 3/8” 80 160 120 400 315 110 370 M16 M12 23 42 110 140 45 10 152 158
NKG 125-80-400 125 80 125 530 280 355 1/2” 80 160 120 435 355 110 370 M16 M12 31 42 110 140 45 10 225 201
NKG 125-100-160 125 100 125 500 200 280 3/8” 80 160 120 360 280 110 370 M16 M12 21 32 80 140 35 10 99 -
NKG 125-100-200 125 100 125 500 200 280 1/2” 80 160 120 360 280 110 370 M16 M12 23 32 80 140 35 10 107 -
NKG 125-100-250 125 100 140 530 225 280 1/2” 80 160 120 400 315 110 370 M16 M12 24 42 110 140 45 12 133 -
NKG 125-100-315 125 100 140 530 250 315 1/2” 80 160 120 400 315 110 370 M16 M12 23 42 110 140 45 12 161 -
NKG 125-100-400 125 100 140 530 280 355 1/2” 100 200 150 500 400 110 370 M20 M12 30 42 110 140 45 12 242 -
NKG 150-125-200 150 125 140 500 250 315 1/2” 80 160 120 400 315 110 370 M16 M12 23 42 110 140 45 12 135 -
NKG 150-125-250 150 125 140 530 250 355 1/2” 80 160 120 400 315 110 370 M16 M12 23 42 110 140 45 12 158 -
NKG 150-125-315 150 125 140 530 280 355 1/2” 100 200 150 500 400 110 370 M20 M12 26 42 110 140 45 12 190 -
NKG 150-125-400 150 125 140 530 315 400 1/2” 100 200 150 500 400 110 370 M20 M12 38 42 110 140 45 12 254 -
NKG 150-125-500 150 125 180 670 400 500 1/2” 125 200 150 625 500 140 500 M20 M16 49 60 110 180 64 18 503 -
NKG 200-150-200 200 150 160 500 280 400 1/2” 100 200 150 550 450 110 370 M20 M16 27 32 80 180 35 10 190 -
NKG 200-150-250 200 150 160 530 280 375 1/2” 100 200 150 500 400 110 370 M20 M16 33 42 110 180 45 12 195 -
NKG 200-150-315 200 150 160 670 315 400 1/2” 100 200 150 550 450 140 500 M20 M16 33 48 110 180 51.5 14 324 -
NKG 200-150-400 200 150 160 670 315 450 1/2” 100 200 150 550 450 140 500 M20 M16 28 48 110 180 51.5 14 366 -
NKG 200-150-500 200 150 180 670 400 500 1/2” 125 200 150 625 500 140 500 M20 M16 43 60 110 180 64 18 523 -
(1 CI: Cast iron version
(2 SS: Stainless steel version
39
NKG bare shaft pumps NBG, NBGE, NKG, NKGE
Flange dimensions AS2129 table E (Standard for all cast iron pumps)
The flange dimensions are stated in mm.
Flange diameter A 140 150 165 185 200 220 250 285 340
TM02 7720 3803
Hole PCD B 87 98 114 127 146 178 210 235 292
Flange thickness C 18 18 20 20 22 24 26 26 30
Hole diameter D 14 14 18 18 18 18 18 22 22
Number of holes N 4 4 4 4 4 8 8 8 8
EN 1092-1 - PN 16
D1
Nominal diameter (DN)
S
EN 1092-2 - PN 16
D1
Nominal diameter (DN)
S
40
Curve charts and NBG, NBGE, NKG, NKGE
technical data
How to read the curve charts
1 2 3 4
p H
[kPa] [m]
14
NBG/NKG 80-65-160
4-pole, 50 Hz
120 12 ISO 9906 Annex A
/177 66 % 69 % 72 % 76 %
80 %
81.6 %
10 /175
/158 80 %
80 80.9 %
8 76.1 %
/143 76 %
6 /131 72.4 % NPSH
72 % [m]
40 4 70.9 % 2
2 NPSH 1
0 0 0
P2 0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
[kW]
/177
1.5 /175
1.0 /158
/143
0.5 /131
0.0
0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
41
Curve charts and NBG, NBGE, NKG, NKGE
technical data
Curve conditions Performance tests
The guidelines below apply to the curves shown in the The requested duty point for every pump is tested
performance charts on page 44 to 165. according to ISO 9906, Annex A (AS2417, Annex A),
and without certification.
• Tolerances according to ISO 9906, Annex A.
• The curves show pump performance with different If the customer requires either more points on the curve
impeller diameters at the nominal speed. to be checked or certain minimum performances or cer-
• The bold part of the curves show the recom- tificates, individual measurements must be made.
mended operating range.
• The thin parts are not recommended as the possible Certificates
operating range here might suggest the selection of Certificates have to be confirmed for every order and
a smaller/larger pump type. are available on request, please contact Grundfos.
• Do not use the pumps at minimum flow rates below
0.1 x Qmax because of the danger of overheating Technical data
the pump.
The pump dimensions on the following pages include
• The curves apply to the pumping of water at a tem-
perature of +20 °C and a kinematic viscosity of • NBG/NKG:
1 mm2/s (1 cSt). Data based on pumps fitted with Grundfos MG or
MMG-G eff1 motors.
• Eta: The dashed lines show values of the hydraulic
efficiency of the pump. • NBGE/NKGE:
Data on pumps fitted with motors with built-in fre-
• NPSH: The curves show average values measured
quenct converter, type Grundfos MGE.
under the same conditions as the performance
curves.
When sizing the pump, add a safety margin of at
least 0.5 m.
• In case of other densities than 1000 kg/m3, the
discharge pressure is proportional to the density.
• When pumping liquids with a density higher than
1000 kg/m3, motors with correspondingly higher
outputs must be used.
Hstat : Differential
the pump.
head between the suction and discharge side of
42
Overview – Curves/ NBG, NBGE, NKG, NKGE
technical data
2-pole 4-pole
Pump type See page Pump type See page
NBG, NKG 50-32-160 44 NBG, NKG 50-32-160 98
NBG, NKG 50-32-200 46 NBG, NKG 50-32-200 100
NBG, NKG 65-50-160 48 NBG, NKG 65-50-160 102
NBG, NKG 65-40-200 50 NBG, NKG 65-40-200 104
NBG, NKG 65-40-250 52 NBG, NKG 65-40-250 106
NBG, NKG 65-40-315 54 NBG, NKG 65-40-315 108
NBG, NKG 80-65-160 56 NBG, NKG 80-65-160 110
NBG, NKG 80-50-200 58 NBG, NKG 80-50-200 112
NBG, NKG 80-50-250 60 NBG, NKG 80-50-250 114
NBG, NKG 80-50-315 62 NBG, NKG 80-50-315 116
NBG, NKG 100-80-160 64 NBG, NKG 100-80-160 118
NBG, NKG 100-65-200 66 NBG, NKG 100-65-200 120
NBG, NKG 100-65-250 68 NBG, NKG 100-65-250 122
NBG, NKG 100-65-315 70 NBG, NKG 100-65-315 124
NBG, NKG 125-80-160 72 NBG, NKG 125-80-160 126
NBG, NKG 125-80-200 74 NBG, NKG 125-80-200 128
NBG, NKG 125-80-250 76 NBG, NKG 125-80-250 130
NBG, NKG 125-80-315 78 NBG, NKG 125-80-315 132
NBG, NKG 125-100-160 80 NBG, NKG 125-80-400 134
NBG, NKG 125-100-200 82 NBG, NKG 125-100-160 136
NBG, NKG 125-100-250 84 NBG, NKG 125-100-200 138
NBG, NKG 125-100-315 86 NBG, NKG 125-100-250 140
NBG, NKG 150-125-200 88 NBG, NKG 125-100-315 142
NBG, NKG 150-125-250 90 NBG, NKG 125-100-400 144
NBG, NKG 150-125-315 92 NBG, NKG 150-125-200 146
NBG, NKG 200-150-200 94 NBG, NKG 150-125-250 148
NBG, NKG 200-150-250 96 NBG, NKG 150-125-315 150
NBG, NKG 150-125-400 152
NBG, NKG 150-125-500 154
NBG, NKG 200-150-200 156
NBG, NKG 200-150-250 158
NBG, NKG 200-150-315 160
NBG, NKG 200-150-400 162
NBG, NKG 200-150-500 164
43
Technical data/ NBG, NKG 50-32-160
2-pole
Performance curves
p H
[kPa] [m]
55 NBG/NKG 50-32-160
500 50 2-pole, 50 Hz
ISO 9906 Annex A
45 /177
55 % 59 %
62 %
400 65 %
40 66.6 %
/163
35 65 %
/151 65.5 % NPSH
300 30 [m]
62.4 % 62 %
/139
25 4
59.3 % 59 %
200 20 3
15 2
100 10 NPSH 1
5 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Q [m³/h]
P2
[kW]
6
/177
4 /163
/151
2 /139
0 1 2 3 4 5 6 7 8 9 10 Q [l/s]
44
Technical data NBG, NKG 50-32-160
2-pole
45
Performance curves NBG, NKG 50-32-200
2-pole
p H
[kPa] [m]
800 80
NBG/NKG 50-32-200
2-pole, 50 Hz
70 /219 ISO 9906 Annex A
52 % 55 % 58 %
63 %
600 60 /206 64.3 %
66.3 %
50 /190
200 20 NPSH 2
10 0
P2 0 4 8 12 16 20 24 28 32 36 40 Q [m³/h]
[kW]
/219
8
/206
/190
4 /176
0 2 4 6 8 10 12 Q [l/s]
46
Technical data NBG, NKG 50-32-200
2-pole
47
Performance curves NBG, NKG 65-50-160
2-pole
p H
[kPa] [m]
55 NBG/NKG 65-50-160
500 50 2-pole, 50 Hz
/177 62 % 66 % 69 % ISO 9906 Annex A
45 72 % 75 %
/172
77.8 %
400 40 77.8 %
/158
35 75 %
76.4 %
300 30 /144
66.8 %
66 %
NPSH
25 62 % [m]
200 20 4
15 3
100 10 NPSH 2
5 1
60 Q [m³/h]
P2 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56
[kW]
8 /177
/172
6
/158
4 /144
2
0 2 4 6 8 10 12 14 16 Q [l/s]
48
Technical data NBG, NKG 65-50-160
2-pole
49
Performance curves NBG, NKG 65-40-200
2-pole
p H
[kPa] [m]
800 80
NBG/NKG 65-40-200
2-pole, 50 Hz
70 ISO 9906 Annex A
/219 55 % 60 % 63 %
66 %
600 68 %
60 /206
69.3 %
50 67.9 % NPSH
/188 [m]
400 40 66.0 % 4
/172
65.2 %
30 3
200 20 2
NPSH
10 1
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]
P2
[kW]
/219
12
/206
8 /188
/172
4
0 2 4 6 8 10 12 14 16 18 Q [l/s]
50
Technical data NBG, NKG 65-40-200
2-pole
51
Performance curves NBG, NKG 65-40-250
2-pole
p H
[kPa] [m]
120 NBG/NKG 65-40-250
110 2-pole, 50 Hz
1000 100 ISO 9906 Annex A
/260 57 % 60 % 62 %
64 %
90 /255 65.4 %
800 80 /245
65.7 %
70 65.3 %
/230 64.7 %
64 %
NPSH
600 60 [m]
/211 64.7 %
50 8
400 40 6
NPSH
30 4
200 20 2
10 0
P2
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [m³/h]
[kW] /260
20 /255
/245
15 /230
10 /211
0 2 4 6 8 10 12 14 16 18 20 Q [l/s]
52
Technical data NBG, NKG 65-40-250
2-pole
53
Performance curves NBG, NKG 65-40-315
2-pole
p H
[kPa] [m]
2000 200 NBG/NKG 65-40-315
2-pole, 50 Hz
180
ISO 9906 Annex A
1600 160
/336 31 % 34 %
38 %
140 /318
40.3 %
1200 120 /298
40.3 %
/273 40.3 %
100
34.9 % NPSH
800 80 34 %
[m]
60 8
NPSH
400 40 4
20 0
P2
0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
[kW]
/336
40
/318
/298
20 /273
0 2 4 6 8 10 12 14 Q [l/s]
54
Technical data NBG, NKG 65-40-315
2-pole
55
Performance curves NBG, NKG 80-65-160
2-pole
p H
[kPa] [m]
55 NBG/NKG 80-65-160
500 50 2-pole, 50 Hz
/177 70 % 74 % 76 % ISO 9906 Annex A
45 78 % 80 %
400 40 /167 81.8 %
35 78.6 %
/150
300 30
74.2 %
/136
25
71.6 % NPSH
200 20 [m]
15 6
100 10 4
NPSH
5 2
0 0 0
P2 0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
[kW]
12 /177
/167
8 /150
/136
4
0 5 10 15 20 25 30 Q [l/s]
56
Technical data NBG, NKG 80-65-160
2-pole
57
Performance curves NBG, NKG 80-50-200
2-pole
p H
[kPa] [m]
90 NBG/NKG 80-50-200
2-pole, 50 Hz
800 80 ISO 9906 Annex A
70 /219 71 % 74 % 76 %
78 %
/210 79.3 %
600 60 78 %
/198 78.4 %
76 %
50
76.5 % 74 % NPSH
/181 [m]
75.0 %
400 40 6
30 4
200 20 NPSH 2
10 0
P2 0 10 20 30 40 50 60 70 80 90 100 Q [m³/h]
[kW]
20 /219
/210
15 /198
10 /181
0 5 10 15 20 25 30 Q [l/s]
58
Technical data NBG, NKG 80-50-200
2-pole
59
Performance curves NBG, NKG 80-50-250
2-pole
p H
[kPa] [m]
120 NBG/NKG 80-50-250
110 2-pole, 50 Hz
1000 100 /263
ISO 9906 Annex A
65 % 68 %
/254 70 %
90 71.4 %
800 71.0 %
80 70 %
/233 68 % NPSH
70 /222 70.1 % [m]
69.9 %
600 60 /205 10
69.2 %
50 8
65 %
400 40 6
30 4
200 20 NPSH 2
10 0
20 /233
/222
/205
10
0 5 10 15 20 25 30 Q [l/s]
60
Technical data NBG, NKG 80-50-250
2-pole
61
Performance curves NBG, NKG 80-50-315
2-pole
p H
[kPa] [m]
2000 200 NBG/NKG 80-50-315
2-pole, 50 Hz
180
ISO 9906 Annex A
1600 160 /321 48 % 51 % 54 %
57 %
140 59.2 %
/300
60 15
NPSH
400 40 10
20 5
P2 0 10 20 30 40 50 60 70 80 Q [m³/h]
[kW]
60
/321
40 /300
/285
/267
20
0 5 10 15 20 25 Q [l/s]
No NBG
62
Technical data NBG, NKG 80-50-315
2-pole
63
Performance curves NBG, NKG 100-80-160
2-pole
p H
[kPa] [m]
55 NBG/NKG 100-80-160
500 50 2-pole, 50 Hz
ISO 9906 Annex A
45 /177 77 % 80 %
83 % 85 %
400 40 /173
86.8 %
/157 85 %
35
86.2 %
300 30 83.5 %
/143 83 % NPSH
25 [m]
81.3 %
200 20 80 % 6
15 4
NPSH
100 10 2
5 0
0 5 10 15 20 25 30 35 40 Q [l/s]
64
Technical data NBG, NKG 100-80-160
2-pole
65
Performance curves NBG, NKG 100-65-200
2-pole
p H
[kPa] [m]
90 NBG/NKG 100-65-200
800
2-pole, 50 Hz
80
ISO 9906 Annex A
/219 72 % 75 % 78 %
70 81 %
/217 82.5 %
600 60 81 %
/198 82.1 % 78 %
/190 78.8 % 75 %
50 79.9 %
/177
76.5 % 72 %
NPSH
400 40 /162 [m]
74.2 %
30 6
200 20 4
10 NPSH 2
0 0 0
0 5 10 15 20 25 30 35 40 45 Q [l/s]
66
Technical data NBG, NKG 100-65-200
2-pole
67
Performance curves NBG, NKG 100-65-250
2-pole
p H
[kPa] [m]
130 NBG/NKG 100-65-250
1200
120 2-pole, 50 Hz
ISO 9906 Annex A
110 67 % 70 % 72 %
/270
1000 100 75 %
/269 75.3 %
90 /251 75 %
50 6
400 40 NPSH 4
30 2
0 5 10 15 20 25 30 35 40 45 Q [l/s]
68
Technical data NBG, NKG 100-65-250
2-pole
69
Performance curves NBG, NKG 100-65-315
2-pole
p H
[kPa] [m]
180
NBG/NKG 100-65-315
2-pole, 50 Hz
1600 160 ISO 9906 Annex A
/320 67 % 70 % 72 %
NPSH
60 4
400 40 0
0 10 20 30 40 50 60 Q [l/s]
70
Technical data NBG, NKG 100-65-315
2-pole
71
Performance curves NBG, NKG 125-80-160
2-pole
p H
[kPa] [m]
500 50 NBG/NKG 125-80-160
2-pole, 50 Hz
45
ISO 9906 Annex A
/177 72 % 75 %
400 40 77 %
79 %
/167 80.6 %
35
/161 79 %
300 79.1 % 77 %
30
/151 78.5 75 %
% NPSH
25
/147-127 78.2 % [m]
200 20 78.0 % 8
72 %
15 6
100 10 4
NPSH
5 2
P2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 Q [m³/h]
[kW]
30
/177
20 /167
/161
/151
10 /147-127
0 10 20 30 40 50 60 70 Q [l/s]
72
Technical data NBG, NKG 125-80-160
2-pole
73
Performance curves NBG, NKG 125-80-200
2-pole
p H
[kPa] [m]
90 NBG/NKG 125-80-200
800
2-pole, 50 Hz
80
ISO 9906 Annex A
/222 72 % 75 % 77 % 79 %
70
82.0 %
/211
600 60
/200 79.5 % 79 %
79.2 % 77 % NPSH
50 /188
75.5 %
75 % [m]
400 /171 72 %
40 8
73.3 %
30 6
200 20 4
NPSH
10 2
0 0 0
280 Q [m³/h]
P2 0 20 40 60 80 100 120 140 160 180 200 220 240 260
[kW]
/222
/211
40
/200
/188
20 /171
0 10 20 30 40 50 60 70 80 Q [l/s]
74
Technical data NBG, NKG 125-80-200
2-pole
75
Performance curves NBG, NKG 125-80-250
2-pole
p H
[kPa] [m]
130 NBG/NKG 125-80-250
1200 120 2-pole, 50 Hz
110 72 % 75 % 78 % ISO 9906 Annex A
/270
81 %
1000 100 81.9 %
/257
90 81 %
78 %
800 80 /234 80.6 %
79.4 % NPSH
70 /220 78.9 % 75 % [m]
72 %
600 60 8
50 6
400 40 4
NPSH
30 2
200 20 0
P2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Q [m³/h]
[kW]
/270
80
/257
60
/234
40 /220
20
0 10 20 30 40 50 60 70 80 Q [l/s]
76
Technical data NBG, NKG 125-80-250
2-pole
77
Performance curves NBG, NKG 125-80-315
2-pole
p H
[kPa] [m]
2000 200 NBG/NKG 125-80-315
2-pole, 50 Hz
180 ISO 9906 Annex A
1600 160 /328 67 % 70 % 73 % 76 %
77.8 %
/310 76 %
140 76.6 % 73 %
/295
1200 120
76.6 % NPSH
/278
[m]
100 74.2 % 12
800 80 8
NPSH
60 4
400 40 0
P2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Q [m³/h]
[kW]
160 /328
/310
120 /295
/278
80
40
0 10 20 30 40 50 60 70 80 90 Q [l/s]
78
Technical data NBG, NKG 125-80-315
2-pole
79
Performance curves NBG, NKG 125-100-160
2-pole
p H
[kPa] [m]
500 50 NBG/NKG 125-100-160
45 2-pole, 50 Hz
/176
74 % 77 %
ISO 9906 Annex A
400 40 80 %
/169 83 %
35 84.6 %
/160-156
84.4 83 %
300 30 % 80 %
77 %
74 %
25
84.1 % NPSH
200 20 [m]
15 12
100 10 8
NPSH
5 4
0 0 0
P2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 Q [m³/h]
[kW]
30 /176
/169
20 /160-156
10
0 10 20 30 40 50 60 70 80 90 Q [l/s]
80
Technical data NBG, NKG 125-100-160
2-pole
81
Performance curves NBG, NKG 125-100-200
2-pole
p H
[kPa] [m]
90 NBG/NKG 125-100-200
800
2-pole, 50 Hz
80
ISO 9906 Annex A
70 /219 70 % 75 % 78 %
81 %
600 60 /203 83.3 %
/192
50 81.9 %
/181 81 %
81.2 % NPSH
400 40 /170
76.3 % [m]
75 %
30 10
70 %
71.7 %
200 20 8
10 6
NPSH
0 0 4
P2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 Q [m³/h]
[kW]
/219
60
/203
40 /192
/181
/170
20
82
Technical data NBG, NKG 125-100-200
2-pole
83
Performance curves NBG, NKG 125-100-250
2-pole
p H
[kPa] [m]
130 NBG/NKG 125-100-250
1200 120 2-pole, 50 Hz
110 65 % ISO 9906 Annex A
72 % 75 %
/270 78 %
1000 100 80.2 %
/258
90 78.6 % 78 %
/242
800 80 76.8 % 75% NPSH
/229
70 75.4 % [m]
600 60 /205 62 % 65 % 72 % 16
66.5 %
50 65 % 12
62 %
400 40 8
30 NPSH 4
200 20 0
P2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 Q [m³/h]
[kW]
120 /270
/258
80 /242
/229
/205
40
84
Technical data NBG, NKG 125-100-250
2-pole
85
Performance curves NBG, NKG 125-100-315
2-pole
p H
[kPa] [m]
2000 200 NBG/NKG 125-100-315
2-pole, 50 Hz
180
ISO 9906 Annex A
1600 160 /322 71 % 74 % 77 % 79 %
80.3 %
140
/301
1200 78.6 % 79 %
120 /284 77 %
/269 77.3 % NPSH
100
[m]
800 80 76.1 % 12
74 %
60 8
NPSH
400 40 4
20 0
P2 0 40 80 120 160 200 240 280 320 360 400 440 Q [m³/h]
[kW]
200 /322
150 /301
/284
100 /269
50
86
Technical data NBG, NKG 125-100-315
2-pole
87
Performance curves NBG, NKG 150-125-200
2-pole
p H
[kPa] [m]
90 NBG/NKG 150-125-200
800
2-pole, 50 Hz
80
ISO 9906 Annex A
70 /226 71 % 74 %
77 %
79 %
600 /219
60 /209 80.4 %
79.7 %
79 %
50 /196-188 78.4 %
77 %
400 40
75.1 %
/196-166 74 % NPSH
30
[m]
71.8 %
200 20 71 % 12
10 NPSH 8
0 0 4
P2 0 50 100 150 200 250 300 350 400 450 500 550 Q [m³/h]
[kW]
100 /226
/219
80
/209
60
/196-188
40 /196-166
88
Technical data NBG, NKG 150-125-200
2-pole
89
Performance curves NBG, NKG 150-125-250
2-pole
p H
[kPa] [m]
130 NBG/NKG 150-125-250
1200
120 2-pole, 50 Hz
ISO 9906 Annex A
110
71 % 74 % 77 %
1000 100 /269
80 %
83 %
/261 85.1 %
90
84.3
/248 %
800 80
83.2 % NPSH
/235
70 82.0 % [m]
/221
600 60 80.7 % 12
50 8
NPSH
400 40 4
30 0
P2 0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
[kW]
/269
160 /261
120 /248
/235
80 /221
90
Technical data NBG, NKG 150-125-250
2-pole
91
Performance curves NBG, NKG 150-125-315
2-pole
p H
[kPa] [m]
180 NBG/NKG 150-125-315
2-pole, 50 Hz
1600 160 ISO 9906 Annex A
71 % 74 % 77 %
/317 81 %
140 82.5 %
/297 81 %
1200 120 81.1 %
/277 77 %
100
79.9 % 74 % NPSH
/262
77.1 % 71 %
[m]
800 80 15
60 10
NPSH
400 40 5
20 0
P2 0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
[kW]
250 /317
200 /297
150 /277
/262
100
92
Technical data NBG, NKG 150-125-315
2-pole
93
Performance curves NBG, NKG 200-150-200
2-pole
p H
[kPa] [m]
70
NBG/NKG 200-150-200
2-pole, 50 Hz
600 60 ISO 9906 Annex A
/224 72 % 76 %
79 %
82 %
50 /218-202
85.6 %
400 40 /216-176
82.5 % 82 %
79 %
30 NPSH
76 % [m]
79.5 %
200 20 72 % 10
NPSH
10 8
0 0 6
P2 0 100 200 300 400 500 600 700 800 900 Q [m³/h]
[kW]
100 /224
/218-202
80
/216-176
60
94
Technical data NBG, NKG 200-150-200
2-pole
95
Performance curves NBG, NKG 200-150-250
2-pole
p H
[kPa] [m]
110 NBG/NKG 200-150-250
1000 100 2-pole, 50 Hz
/275 68 %
71 % ISO 9906 Annex A
74 %
90
/260
800 80 77.9 %
/245
70 76.1 %
600 /230
60 74.1 %
NPSH
50 72.1 %
[m]
400 40 16
30 12
NPSH
200 20 8
10 4
P2 0 100 200 300 400 500 600 700 800 900 Q [m³/h]
[kW]
250 /275
200 /260
150 /245
/230
100
96
Technical data NBG, NKG 200-150-250
2-pole
97
Performance curves NBG, NKG 50-32-160
4-pole
p H
[kPa] [m]
140 14
NBG/NKG 50-32-160
4-pole, 50 Hz
120 12 ISO 9906 Annex A
/177
/172 59 % 62 %
65 % 68 %
100 10 70.3 %
68 %
80 8
69.1 %
60 6 NPSH
[m]
40 4 1.0
20 2 0.5
NPSH
0 0 0.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [m³/h]
P2
[kW]
0.6 /177
/172
0.4
0.2
0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Q [l/s]
98
Technical data NBG, NKG 50-32-160
4-pole
99
Performance curves NBG, NKG 50-32-200
4-pole
p H
[kPa] [m]
200 20 NBG/NKG 50-32-200
4-pole, 50 Hz
18 ISO 9906 Annex A
/219
160 16 54 %
/216 57 %
60 %
14 61.0 %
/200
120 12 61.0 %
/184 62.3 %
10
NPSH
[m]
58.2 %
80 8 1.0
6 NPSH 0.5
40 4 0.0
P2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Q [m³/h]
[kW]
1.2 /219
/216
0.8 /200
/184
0.4
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [l/s]
100
Technical data NBG, NKG 50-32-200
4-pole
101
Performance curves NBG, NKG 65-50-160
4-pole
p H
[kPa] [m]
14
NBG/NKG 65-50-160
4-pole, 50 Hz
120 12 ISO 9906 Annex A
/177 59 % 65 % 68 %
71 %
72.0 %
10 /166 71 %
68 %
80 69.6 %
8 /151 65 %
67.6 %
6 NPSH
[m]
40 4 1.0
2 0.5
NPSH
0 0 0.0
P2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Q [m³/h]
[kW]
/177
0.8 /166
/151
0.4
0.0
0 1 2 3 4 5 6 7 8 Q [l/s]
102
Technical data NBG, NKG 65-50-160
4-pole
103
Performance curves NBG, NKG 65-40-200
4-pole
p H
[kPa] [m]
18 NBG/NKG 65-40-200
4-pole, 50 Hz
160 /219
16 60 % 63 %
66 % ISO 9906 Annex A
/217 68 %
14 69.8 %
/198
120 12 68 %
69.7 %
67.2 %
/181
10
80 8 66.1 % NPSH
66 %
[m]
6 2
NPSH
40 4 1
2 0
P2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Q [m³/h]
[kW]
1.5 /219
/217
1.0 /198
/181
0.5
0 1 2 3 4 5 6 7 8 9 Q [l/s]
104
Technical data NBG, NKG 65-40-200
4-pole
105
Performance curves NBG, NKG 65-40-250
4-pole
p H
[kPa] [m]
26 NBG/NKG 65-40-250
240
24 /260 4-pole, 50 Hz
60 % 62 % ISO 9906 Annex A
22 64 %
/245 65.4 %
200 20
64 %
18 64.4 %
160 /219
16
NPSH
14 64.0 % [m]
120 12 3
10 2
80 8 1
NPSH
6 0
P2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Q [m³/h]
[kW]
3
/260
2 /245
/219
1
0 1 2 3 4 5 6 7 8 9 10 Q [l/s]
106
Technical data NBG, NKG 65-40-250
4-pole
107
Performance curves NBG, NKG 65-40-315
4-pole
p H
[kPa] [m]
480 48 NBG/NKG 65-40-315
44 4-pole, 50 Hz
/344
32 % 35 % ISO 9906 Annex A
400 40 /334 38 %
41 %
36 41.5 %
41 %
320 32
/305 41.5 %
38 %
28
/283 37.4 % 35 % NPSH
240 24 [m]
37.4 %
20 12
160 16 32 % 8
12 4
NPSH
80 8 0
P2 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Q [m³/h]
[kW]
6 /344
/334
4 /305
/283
2
0 1 2 3 4 5 6 7 8 Q [l/s]
108
Technical data NBG, NKG 65-40-315
4-pole
109
Performance curves NBG, NKG 80-65-160
4-pole
p H
[kPa] [m]
14
NBG/NKG 80-65-160
4-pole, 50 Hz
120 12 ISO 9906 Annex A
/177 66 % 69 % 72 % 76 %
80 %
81.6 %
10 /175
/158 80 %
80 80.9 %
8 76.1 %
/143 76 %
6 /131 72.4 % NPSH
72 % [m]
40 4 70.9 % 2
2 NPSH 1
0 0 0
P2 0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
[kW]
/177
1.5 /175
1.0 /158
/143
0.5 /131
0 2 4 6 8 10 12 14 Q [l/s]
110
Technical data NBG, NKG 80-65-160
4-pole
111
Performance curves NBG, NKG 80-50-200
4-pole
p H
[kPa] [m]
200 20 NBG/NKG 80-50-200
4-pole, 50 Hz
18 ISO 9906 Annex A
/219 70 % 73 %
160 77 %
16 /210
78.6 %
14 80.7% 77 %
120 /188 73 %
12
75.7 % 70 %
10
/171 NPSH
74.7 % [m]
80 8 2
6 1
NPSH
40 4 0
P2 0 5 10 15 20 25 30 35 40 45 50 55 Q [m³/h]
[kW]
/219
/210
2
/188
1 /171
0 2 4 6 8 10 12 14 16 Q [l/s]
112
Technical data NBG, NKG 80-50-200
4-pole
113
Performance curves NBG, NKG 80-50-250
4-pole
p H
[kPa] [m]
26 NBG/NKG 80-50-250
240 /263
4-pole, 50 Hz
24 63 % 66 %
69 % 70 % ISO 9906 Annex A
22 71.9 %
200 20 /241
70 %
69 %
18
70.3 % 66 %
160
/221 NPSH
16 63 %
69.8 %
[m]
14 3
120 12 2
10 1
NPSH
80 8 0
P2 0 5 10 15 20 25 30 35 40 45 50 55 Q [m³/h]
[kW]
4 /263
3 /241
2 /221
0 2 4 6 8 10 12 14 16 Q [l/s]
114
Technical data NBG, NKG 80-50-250
4-pole
115
Performance curves NBG, NKG 80-50-315
4-pole
p H
[kPa] [m]
55 NBG/NKG 80-50-315
500 4-pole, 50 Hz
50
ISO 9906 Annex A
45 /344 50 % 53 %
56 %
/333 59 %
400 40 60.7 %
60.1 %
35 /303
300 30 58.7 %
/277
NPSH
25 57.7 % [m]
200 20 8
15 NPSH 4
100 10 0
P2 0 5 10 15 20 25 30 35 40 45 Q [m³/h]
[kW]
8 /344
/333
6
/303
4 /277
2
0 2 4 6 8 10 12 14 Q [l/s]
116
Technical data NBG, NKG 80-50-315
4-pole
117
Performance curves NBG, NKG 100-80-160
4-pole
p H
[kPa] [m]
120 12 NBG/NKG 100-80-160
11 4-pole, 50 Hz
/177 75 % 78 %
81 % ISO 9906 Annex A
100 84 %
10
/165 86.7 %
9
80 8
84.5 % 84 %
/149
7
82.2 % 81 %
60 6 /138
NPSH
5 81.0 % 78 % [m]
40 4 2
3 NPSH 1
20 2 0
P2 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Q [m³/h]
[kW]
2.0 /177
1.5 /165
1.0 /149
/138
0.5
0 2 4 6 8 10 12 14 16 18 20 22 Q [l/s]
118
Technical data NBG, NKG 100-80-160
4-pole
119
Performance curves NBG, NKG 100-65-200
4-pole
p H
[kPa] [m]
200 20 NBG/NKG 100-65-200
4-pole, 50 Hz
18 ISO 9906 Annex A
/219 72 % 75 %
78 %
81 %
160 16 82.2 %
/205
81 %
14 81.9 %
78 %
120 /189 75 %
12
77.8 %
10 /170
72 % NPSH
[m]
75.2 %
80 8 2
6 1
NPSH
40 4 0
P2 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Q [m³/h]
[kW] /219
3 /205
2 /189
/170
1
0 2 4 6 8 10 12 14 16 18 20 22 Q [l/s]
120
Technical data NBG, NKG 100-65-200
4-pole
121
Performance curves NBG, NKG 100-65-250
4-pole
p H
[kPa] [m]
320 32
NBG/NKG 100-65-250
4-pole, 50 Hz
28 ISO 9906 Annex A
/270 65 % 68 %
71 %
240 74 %
24
/254 75.4 %
74 %
20 74.2 % NPSH
/232
[m]
160 /215 72.9 %
16 3
72.1 %
71 %
12 2
80 NPSH
8 1
4 0
P2 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Q [m³/h]
[kW]
/270
6
/254
4 /232
/215
2
0 2 4 6 8 10 12 14 16 18 20 22 24 Q [l/s]
122
Technical data NBG, NKG 100-65-250
4-pole
123
Performance curves NBG, NKG 100-65-315
4-pole
p H
[kPa] [m]
44 NBG/NKG 100-65-315
4-pole, 50 Hz
400 40 ISO 9906 Annex A
/320 63 % 66 %
69 %
36 /314 72 %
73.2 %
320 32 72 %
73.1 %
28 /282 69 % NPSH
[m]
70.3 %
240 24 /261 3
69.9 %
20 2
NPSH
160 16 1
12 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Q [l/s]
124
Technical data NBG, NKG 100-65-315
4-pole
125
Performance curves NBG, NKG 125-80-160
4-pole
p H
[kPa] [m]
12 NBG/NKG 125-80-160
11 4-pole, 50 Hz
100 /177 72 % 75 % ISO 9906 Annex A
10
78 %
80 %
9 /175 80.5 %
80 8 /161 80 %
80.8 % 78 %
7 79.2 %
/146
60 6
75 %
5 78.2 %
NPSH
40 4 [m]
3 2
NPSH
20 2 1
1 0
0 5 10 15 20 25 30 35 Q [l/s]
126
Technical data NBG, NKG 125-80-160
4-pole
127
Performance curves NBG, NKG 125-80-200
4-pole
p H
[kPa] [m]
200 20 NBG/NKG 125-80-200
4-pole, 50 Hz
18 72 % 75 %
/222 78 % 80 % ISO 9906 Annex A
160 16 /214 81.8 %
14 80.0 % 80 %
/196
120 12 78 %
76.8 %
/179
10 75 %
74.7 % 72 %
/164 NPSH
80 8 73.4 %
[m]
6 2
NPSH
40 4 1
2 0
0 5 10 15 20 25 30 35 Q [l/s]
128
Technical data NBG, NKG 125-80-200
4-pole
129
Performance curves NBG, NKG 125-80-250
4-pole
p H
[kPa] [m]
36 NBG/NKG 125-80-250
320
4-pole, 50 Hz
32
ISO 9906 Annex A
28 /270 72 % 75 % 78 %
80 %
83.1 %
240 24
/247 80 %
78 %
20
/225
79.7 % NPSH
160 16
[m]
78.2 %
12 3
80 8 2
NPSH
4 1
0 0 0
0 5 10 15 20 25 30 35 40 Q [l/s]
130
Technical data NBG, NKG 125-80-250
4-pole
131
Performance curves NBG, NKG 125-80-315
4-pole
p H
[kPa] [m]
500 50 NBG/NKG 125-80-315
4-pole, 50 Hz
45 ISO 9906 Annex A
/334 69 % 72 % 75 %
400 40 78 %
/320 79.2 %
78 % NPSH
35 /305 77.3 %
75 % [m]
300 76.6 %
30 4
/280
25 75.4 % 3
200 20 2
NPSH
15 1
100 10 0
0 5 10 15 20 25 30 35 40 45 50 Q [l/s]
132
Technical data NBG, NKG 125-80-315
4-pole
133
Performance curves NBG, NKG 125-80-400
4-pole
p H
[kPa] [m]
90 NBG/NKG 125-80-400
4-pole, 50 Hz
800 80 ISO 9906 Annex A
/438 59 %
70 62 % 65 %
68 %
/419
70.4 %
600 60 /397 68.7 %
68 %
50 /365
66.0 % 67.2 % NPSH
400 40 /347
[m]
65.4 % 65 %
30 8
200 20 4
NPSH
10 0
0 5 10 15 20 25 30 35 40 45 50 Q [l/s]
134
Technical data NBG, NKG 125-80-400
4-pole
135
Performance curves NBG, NKG 125-100-160
4-pole
p H
[kPa] [m]
11 NBG/NKG 125-100-160
100 /176
4-pole, 50 Hz
10 70 %
74 % ISO 9906 Annex A
77 %
9 /165 80 %
81.2 %
80 8
80 %
/160-144
7 80.2 % 77 %
74 %
60 6 70 %
NPSH
5
76.3 % [m]
40 4 4
3 NPSH 2
20 2 0
0 10 20 30 40 50 Q [l/s]
136
Technical data NBG, NKG 125-100-160
4-pole
137
Performance curves NBG, NKG 125-100-200
4-pole
p H
[kPa] [m]
200 20 NBG/NKG 125-100-200
18 4-pole, 50 Hz
/219 69 % 72 %
75 % 78 % ISO 9906 Annex A
160 16 /211 81 %
82.9 %
14
/195 82.2 %
81 %
120 12 78 %
/178 81.4 %
10
75.0 % NPSH
80 8 [m]
72 %
6 3
40 4 2
NPSH
2 1
0 0 0
0 10 20 30 40 50 60 Q [l/s]
138
Technical data NBG, NKG 125-100-200
4-pole
139
Performance curves NBG, NKG 125-100-250
4-pole
p H
[kPa] [m]
320 32 NBG/NKG 125-100-250
4-pole, 50 Hz
28 /270 65 % 69 % 72 %
75 % 78 % ISO 9906 Annex A
/245 78.6 % 78 %
20 75 %
78.3 % 72 %
160 16 /215 NPSH
72.2 % [m]
12 69 % 3
65 %
80 8 2
NPSH
4 1
0 0 0
10 /245
/215
5
0 10 20 30 40 50 60 Q [l/s]
140
Technical data NBG, NKG 125-100-250
4-pole
141
Performance curves NBG, NKG 125-100-315
4-pole
p H
[kPa] [m]
480 48 NBG/NKG 125-100-315
44 4-pole, 50 Hz
/334 65 % 69 % 72 % 75 % ISO 9906 Annex A
400 40 78 %
80.8 %
36 /312
320 32 /295 78.3 % 78 %
/279 77.0 %
28 75 %
76.4 % NPSH
240 24 [m]
72 %
20 3
160 16 2
NPSH
12 1
80 8 0
0 10 20 30 40 50 60 70 Q [l/s]
142
Technical data NBG, NKG 125-100-315
4-pole
143
Performance curves NBG, NKG 125-100-400
4-pole
p H
[kPa] [m]
800 80
NBG/NKG 125-100-400
4-pole, 50 Hz
/438 63 % 66 % ISO 9906 Annex A
70 69 %
/432
600 /410 71.6 %
60
/387 70.7 %
71.2 %
50 70.2 % NPSH
/351 [m]
69.9 %
400 40 12
30 8
200 20 NPSH 4
10 0
0 10 20 30 40 50 60 Q [l/s]
144
Technical data NBG, NKG 125-100-400
4-pole
145
Performance curves NBG, NKG 150-125-200
4-pole
p H
[kPa] [m]
200 20 NBG/NKG 150-125-200
4-pole, 50 Hz
18
/226 69 % 72 % ISO 9906 Annex A
160 16 76 %
79 %
/221
14 80.4 %
/201
120 79 %
12
80.0 %
/196-172
10 76.9 %
76 % NPSH
80 8 72.8 %
72 %
[m]
6 4
NPSH
40 4 2
2 0
P2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [m³/h]
[kW]
12 /226
/221
8 /201
/196-172
4
0 10 20 30 40 50 60 70 80 Q [l/s]
146
Technical data NBG, NKG 150-125-200
4-pole
147
Performance curves NBG, NKG 150-125-250
4-pole
p H
[kPa] [m]
30 NBG/NKG 150-125-250
280 28 4-pole, 50 Hz
26 72 % 75 % 78 % ISO 9906 Annex A
/269 81 %
240 24 84 %
/262
85.2 %
22
/249 84.2
200 % 84 %
20
/236 82.7 % 81 %
18 78 %
160 81.7 %
16 /220
14 80.7 % 75 % NPSH
120 12 [m]
10 4
80 8 NPSH 2
6 0
P2 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 Q [m³/h]
[kW]
25
/269
20 /262
/249
15 /236
10 /220
0 10 20 30 40 50 60 70 80 90 100 Q [l/s]
148
Technical data NBG, NKG 150-125-250
4-pole
149
Performance curves NBG, NKG 150-125-315
4-pole
p H
[kPa] [m]
500 50 NBG/NKG 150-125-315
4-pole, 50 Hz
45
70 % 74 % 78 % ISO 9906 Annex A
/338
400 82 %
40 /336 83.2 %
/317
35 82 %
82.7 %
78 %
300 30 /290 74 %
80.8 %
/275 NPSH
25
[m]
200 79.6 %
20 6
15 4
NPSH
100 10 2
5 0
0 20 40 60 80 100 Q [l/s]
150
Technical data NBG, NKG 150-125-315
4-pole
151
Performance curves NBG, NKG 150-125-400
4-pole
p H
[kPa] [m]
90 NBG/NKG 150-125-400
800
4-pole, 50 Hz
80
ISO 9906 Annex A
/438 60 % 66 % 71 % 74 %
70
/433 76.5 %
600 60 /392 74 %
76.2 % 70 %
74.3 %
/368
50 73.5 %
/345
NPSH
400 40
72.4 % [m]
30 15
200 20 10
10 NSPH 5
0 0 0
0 20 40 60 80 100 Q [l/s]
152
Technical data NBG, NKG 150-125-400
4-pole
153
Performance curves NBG, NKG 150-125-500
4-pole
p H
[kPa] [m]
140
NBG/NKG 150-125-500
4-pole, 50 Hz
1200 120 ISO 9906 Annex A
/548 64 % 67 %
70 %
/526
100 73.3 %
/500 71.7 %
70.6 % 70 %
/473
800 80 69.8 %
NPSH
/447
69.2 % [m]
/406
60 68.4 % 12
67 %
400 40 8
NPSH
20 4
0 0 0
P2 0 40 80 120 160 200 240 280 320 360 400 440 Q [m³/h]
[kW]
150 /548
/526
100 /500
/473
/447
50 /406
154
Technical data NBG, NKG 150-125-500
4-pole
155
Performance curves NBG, NKG 200-150-200
4-pole
p H
[kPa] [m]
160 16 NBG/NKG 200-150-200
4-pole, 50 Hz
14 /224 72 % ISO 9906 Annex A
76 %
79 %
120 82 %
12 /218-208
85.7 %
10
83.1 %
80 /210-160 82 %
8 79 %
6
77.0 % 76 % NPSH
72 % [m]
40 4 3
NPSH
2 2
0 0 1
156
Technical data NBG, NKG 200-150-200
4-pole
157
Performance curves NBG, NKG 200-150-250
4-pole
p H
[kPa] [m]
320 32 NBG/NKG 200-150-250
4-pole, 50 Hz
28 70 % 73 % ISO 9906 Annex A
/286 76 %
79 %
240 24 /284
81.0 %
/271
20 79.6 79 %
%
/251 76 %
160 16 /238 77.4 73 % NPSH
%
/226
76.1 [m]
%
12 6
70 %
74.3 %
80 8 4
NPSH
4 2
0 0 0
P2 0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
[kW]
40 /286
/284
30 /271
/251
20 /238
/226
10
0
158
Technical data NBG, NKG 200-150-250
4-pole
159
Performance curves NBG, NKG 200-150-315
4-pole
p H
[kPa] [m]
480 50 NBG/NKG 200-150-315
45 4-pole, 50 Hz
ISO 9906 Annex A
400 40 /338 75 % 78 % 81 %
84 %
/336 85.6 %
35
320 /310 84 %
30 /291 82.1 % 85.3 % 81 %
78 %
25 /275 79.8 %
240
75 %
20
77.8 % NPSH
160
15 [m]
10 8
80
NPSH
5 4
0 0 0
P2 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 Q [m³/h]
[kW]
80 /338
60 /336
/310
40 /291
/275
20
0
160
Technical data NBG, NKG 200-150-315
4-pole
161
Performance curves NBG, NKG 200-150-400
4-pole
p H
[kPa] [m]
90 NBG/NKG 200-150-400
800
4-pole, 50 Hz
80
75 % 79 % 82 % ISO 9906 Annex A
/438 85 %
70
/431 87.9 %
600 60 /412 85.9 % 8 85 %
7.2 % 82 %
/394 84.7 79 %
%
50 /375 83.7 %
75 % NPSH
400 40 /343 82.2 %
[m]
30 15
200 20 10
10 NPSH 5
0 0 0
P2 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 Q [m³/h]
[kW]
160
/438
120 /431
/412
80 /394
/375
/343
40
0
162
Technical data NBG, NKG 200-150-400
4-pole
163
Performance curves NBG, NKG 200-150-500
4-pole
p H
[kPa] [m]
1600 160 NBG/NKG 200-150-500
4-pole, 50 Hz
140 ISO 9906 Annex A
1200 120 70 % 73 % 76 %
/548 78.4 %
/521 76 %
100 73 %
/489 78.3 %
800 80 /459
NPSH
77.4 %
[m]
76.6 %
60 12
400 40 8
NPSH
20 4
0 0 0
P2 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 Q [m³/h]
[kW]
300
/548
200 /521
/489
/459
100
164
Technical data NBG, NKG 200-150-500
4-pole
165
Base frames NBG, NBGE, NKG, NKGE
3
TM03 7715 4806
4
TM03 7716 4806
5
TM03 7717 4806
6
TM03 7718 4806
166
9
8
7
11
10
11(Grout)
Base frame type No
Base frames
Base frame
TM04 2069 1908 TM03 7723 4806 TM03 7722 4806 TM03 7721 4806 TM03 7720 4806 TM03 7719 4806
NBG, NBGE, NKG, NKGE
167
Base frames NBG, NBGE, NKG, NKGE
IEC 225/250
IEC 280
TM04 0485 0708
IEC 315
TM04 0484 0708
168
Base frames NBG, NBGE, NKG, NKGE
169
Base frames NBG, NBGE, NKG, NKGE
170
Base frames NBG, NBGE, NKG, NKGE
171
Accessories NBG, NBGE, NKG, NKGE
Support blocks
The product numbers in the tables on the following pages
refer to a set of two support blocks with the dimensions
specified.
Note: Bolts, washers and nuts are not supplied together
with support blocks.
Base frames
As an additional feature a base frame for improving the
installation, to apply between the foundation and support,
is available.
When ordering a base frame as an accessery the relevant
support blocks, bolts, nuts and washers are always
included.
No Description
1 Support blocks to be fitted under motor feet
2 Support blocks to be fitted under pump housing feet
Support blocks to be fitted under both motor and
3
pump housing feet
172
Accessories NBG, NBGE, NKG, NKGE
173
Accessories NBG, NBGE, NKG, NKGE
Support Dimensions
Pump P2 Product number
block WxLxH [mm]
Support under
Base frame
motor Support under
Type [kw] No. Motor Pump
MMG-G pump MMG-G
EFF1 EFF1
100-65-315 90 3 130 x 550 x 5 80 x 160 x 20 95921028 95921132 95921836
80 x 160 x 20
80 x 160 x 20
100-65-315 110 3 160 x 565 x 30 150 x 160 x 50 95921036 95921135 95921844
150 x 160 x 50
80 x 160 x 20
125-80-160 11 1 80 x 290 x 25 - 95921003 - -
125-80-160 15 1 80 x 290 x 25 - 95921003 - -
125-80-160 18.5 1 80 x 335 x 25 - 95921006 - -
125-80-160 22 1 80 x 320 x 5 - 95921004 - -
125-80-160 30 1 110 x 410 x 10 - 95921007 - -
125-80-200 30 3 110 x 410 x 10 70 x 125 x 30 95921007 95921110 -
125-80-200 37 3 110 x 410 x 10 70 x 125 x 30 95921007 95921110 -
125-80-200 45 3 110 x 420 x 15 70 x 125 x 30 95921011 95921131 95921807
70 x 125 x 30
125-80-200 55 3 130 x 480 x 30 150 x 125 x 50 95921032 95921133 95921820
150 x 125 x 50
125-80-250 45 3 110 x 420 x 10 80 x 160 x 10 95921010 95921112 95921809
125-80-250 55 3 130 x 480 x 35 80 x 160 x 20 95921026 95921132 95921822
80 x 160 x 20
80 x 160 x 20
125-80-250 75 3 130 x 500 x 5 80 x 160 x 20 95921027 95921132 95921827
80 x 160 x 20
80 x 160 x 20
125-80-250 90 3 130 x 550 x 5 80 x 160 x 20 95921028 95921132 95921838
80 x 160 x 20
80 x 160 x 20
125-80-315 90 3 130 x 550 x 5 80 x 160 x 35 95921028 95921113 95921840
125-80-315 110 3 160 x 565 x 35 150 x 160 x 50 95921037 95921134 95921845
150 x 160 x 50
125-80-315 132 3 160 x 615 x 35 150 x 160 x 50 95921029 95921134 95921858
150 x 160 x 50
125-80-315 160 3 160 x 665 x 35 150 x 160 x 50 95921039 95921134 95921867
150 x 160 x 50
125-100-160 22 1 80 x 320 x 20 - 95921005 - -
125-100-160 30 3 110 x 410 x 10 80 x 160 x 10 95921007 95921112 -
125-100-160 37 3 110 x 410 x 10 80 x 160 x 10 95921007 95921112 -
125-100-200 30 3 110 x 410 x 10 80 x 160 x 10 95921007 95921112 -
125-100-200 37 3 110 x 410 x 10 80 x 160 x 10 95921007 95921112 -
125-100-200 45 3 110 x 420 x 10 80 x 160 x 35 95921010 95921113 95921805
125-100-200 55 3 150 x 480 x 50 150 x 160 x 50 95921033 95921134 95921816
150 x 160 x 50
125-100-200 75 3 130 x 500 x 20 150 x 160 x 50 95921034 95921134 95921825
150 x 160 x 50
125-100-250 55 3 130 x 480 x 35 80 x 160 x 20 95921026 95921132 95921818
80 x 160 x 20
80 x 160 x 20
125-100-250 75 3 130 x 500 x 5 80 x 160 x 20 95921027 95921132 95921826
80 x 160 x 20
80 x 160 x 20
125-100-250 90 3 130 x 550 x 5 80 x 160 x 20 95921028 95921132 95921836
80 x 160 x 20
80 x 160 x 20
125-100-250 110 3 160 x 565 x 30 150 x 160 x 50 95921036 95921135 95921844
150 x 160 x 50
80 x 160 x 20
125-100-250 132 3 160 x 615 x 30 150 x 160 x 50 95921031 95921135 95921861
150 x 160 x 50
80 x 160 x 20
125-100-315 110 3 160 x 565 x 35 150 x 160 x 50 95921037 95921134 95921845
150 x 160 x 50
125-100-315 132 3 160 x 615 x 35 150 x 160 x 50 95921029 95921134 95921858
150 x 160 x 50
174
Accessories NBG, NBGE, NKG, NKGE
Support Dimensions
Pump P2 Product number
block WxLxH [mm]
Support under
Base frame
motor Support under
Type [kw] No. Motor Pump
MMG-G pump MMG-G
EFF1 EFF1
125-100-315 160 3 160 x 665 x 35 150 x 160 x 50 95921039 95921134 95921867
150 x 160 x 50
125-100-315 200 3 160 x 665 x 35 150 x 160 x 50 95921039 95921134 95921867
150 x 160 x 50
150-125-200 45 1 110 x 415 x 25 - 95921009 - 95921811
150-125-200 55 3 130 x 480 x 35 80 x 160 x 35 95921026 95921113 95921824
150-125-200 75 3 130 x 500 x 5 80 x 160 x 35 95921027 95921113 95921828
150-125-200 90 3 130 x 550 x 5 80 x 160 x 35 95921028 95921113 95921842
150-125-200 110 3 160 x 565 x 35 150 x 160 x 50 95921037 95921134 95921846
150 x 160 x 50
150-125-250 90 3 130 x 550 x 5 80 x 160 x 35 95921028 95921113 95921840
150-125-250 110 3 160 x 565 x 35 150 x 160 x 50 95921037 95921134 95921845
150 x 160 x 50
150-125-250 132 3 160 x 615 x 35 150 x 160 x 50 95921029 95921134 95921858
150 x 160 x 50
150-125-250 160 3 160 x 665 x 35 150 x 160 x 50 95921039 95921134 95921867
150 x 160 x 50
150-125-250 200 3 160 x 665 x 35 150 x 160 x 50 95921039 95921134 95921867
150 x 160 x 50
150-125-315 132 3 160 x 615 x 25 125 x 200 x 30 95921030 95921130 95921864
125 x 200 x 30
150-125-315 160 3 160 x 665 x 25 125 x 200 x 30 95921038 95921130 95921870
125 x 200 x 30
150-125-315 200 3 160 x 665 x 25 125 x 200 x 30 95921038 95921130 95921870
125 x 200 x 30
200-150-200 75 - - - - - 95921829
200-150-200 90 - - - - - 95921834
200-150-200 110 3 160 x 565 x 25 125 x 200 x 30 95921035 95921130 95921847
125 x 200 x 30
200-150-250 132 3 160 x 615 x 25 125 x 200 x 30 95921030 95921130 95921864
125 x 200 x 30
200-150-250 160 3 160 x 665 x 25 125 x 200 x 30 95921038 95921130 95921870
125 x 200 x 30
200-150-250 200 3 160 x 665 x 25 125 x 200 x 30 95921038 95921130 95921870
125 x 200 x 30
175
Accessories NBG, NBGE, NKG, NKGE
176
Accessories NBG, NBGE, NKG, NKGE
Support Dimensions
Pump P2 Product number
block WxLxH [mm]
Support under
Base frame
motor Support under
Type [kw] No. Motor Pump
MMG-G pump MMG-G
EFF1 EFF1
150-125-400 75 1 130 x 500 x 35 - 95921075 - 95921919
150-125-400 90 1 130 x 550 x 35 - 95921077 - 95921926
150-125-500 55 3 180 x 480 x 180 125 x 200 x 30 95921074 95921100 95921916
150-125-500 75 3 180 x 500 x 180 125 x 200 x 30 95921076 95921130 95921920
125 x 200 x 30
150-125-500 90 3 180 x 550 x 180 125 x 200 x 30 95921078 95921130 95921928
125 x 200 x 30
150-125-500 110 3 220 x 565 x 120 125 x 200 x 35 95921080 95921101 95921931
150-125-500 132 3 220 x 615 x 120 125 x 200 x 35 95921079 95921101 95921939
150-125-500 160 3 220 x 665 x 120 125 x 200 x 35 95921081 95921101 95921945
200-150-200 7.5 3 120 x 285 x 120 100 x 200 x 2 95921138 95921098 -
70 x 285 x 30
200-150-200 11 3 140 x 290 x 140 100 x 200 x 20 95921048 95921121 -
200-150-200 15 3 140 x 335 x 140 100 x 200 x 20 95921054 95921121 -
200-150-250 15 3 140 x 335 x 140 100 x 200 x 20 95921054 95921121 -
200-150-250 18.5 1 150 x 320 x 100 - 95921052 - -
200-150-250 22 1 150 x 360 x 100 - 95921057 - -
200-150-250 30 3 150 x 410 x 100 100 x 200 x 20 95921063 95921121 -
200-150-250 37 3 140 x 390 x 60 100 x 200 x 5 95921058 95921119 95921893
200-150-250 45 3 140 x 415 x 60 100 x 200 x 5 95921072 95921119 95921904
200-150-315 37 3 150 x 390 x 100 100 x 200 x 10 95921059 95921120 95921897
200-150-315 45 3 150 x 415 x 100 100 x 200 x 10 95921073 95921120 95921910
200-150-315 55 1 130 x 480 x 35 - 95921137 - 95921918
130 x 480 x 30
200-150-315 75 1 130 x 500 x 35 - 95921075 - 95921921
200-150-315 90 1 130 x 550 x 35 - 95921077 - 95921930
200-150-400 55 1 130 x 480 x 35 - 95921137 - 95921966
130 x 480 x 30
200-150-400 75 1 130 x 500 x 35 - 95921075 - 95921967
200-150-400 90 1 130 x 550 x 35 - 95921077 - 95921970
200-150-400 110 3 160 x 565 x 25 100 x 200 x 25 95921035 95921099 95921932
200-150-400 132 3 160 x 615 x 25 100 x 200 x 25 95921030 95921099 95921942
200-150-400 160 3 160 x 665 x 25 100 x 200 x 25 95921038 95921099 95921948
200-150-500 132 3 220 x 615 x 120 125 x 200 x 35 95921079 95921101 95921939
200-150-500 160 3 220 x 665 x 120 125 x 200 x 35 95921081 95921101 95921945
200-150-500 200 3 220 x 665 x 120 125 x 200 x 35 95921070 95921101 95921937
177
Further product documentation NBG, NBGE, NKG,
NKGE
WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185,000 Grundfos products in more than 20 languages.
In WebCAPS, all information is divided into 6 sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.
Catalogue
Literature
In this section you can access all the latest documents of a given
pump, such as
• data booklets
• installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures, etc.
Service
178
Further product documentation NBG, NBGE, NKG,
NKGE
Sizing 0 1
Replacement
CAD drawings
2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.
3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.
179
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence
96844990 1108
AU
Subject to alterations.
www.grundfos.com