Sie sind auf Seite 1von 5

LOAD DISTRIBUTION CALCULATION FOR STATICALLY INDETERMINATE STRUCTURE

TL TO TL L 41200 MM

KG/MM
STORAGE TANK KGS
(UDL)
EMPTY WEIGHT STORAGE TANK 130687 3.1720 = W
OPERATING WEIGHT STORAGE TANK 452663 10.9870 = W
TEST WEIGHT STORAGE TANK 789485 19.1623 = W

DEAERATOR KGS
EMPTY WEIGHT DEAERATOR 26337 Wd Wd = weight of
OPERATING WEIGHT DEAERATOR 33685 Wd deaerator
TEST WEIGHT DEAERATOR 104794 Wd

CONDITION KGS
GROSS EMPTY WEIGHT 157024
GROSS OPERATING WEIGHT 486348
GROSS TEST WEIGHT 894279

RA RB RC

Where,
q =W

For Empty Weight including Deaerator weight

LENGTH, L1 = 20600 MM

RA = 3 (W) L1 / 8 24503.8125 31088.0625 KGS


RC = 3 (W) L1 / 8 24503.8125 31088.0625 KGS
RB = 5 (W) L1 /4 81679.375 94847.875 KGS
130687 TOTAL 157024 KGS

For Operating Weight including Deaerator weight

LENGTH,L1 = 20600 MM

RA = 3 (W) L1 /8 84874.3125 93295.5625 KGS


RC = 3 (W) L1 / 8 84874.3125 93295.5625 KGS
RB = 5 (W) L1 /4 282914.375 299756.875 KGS
TOTAL 486348 KGS

For Test Weight including Deaerator weight

LENGTH,L1 = 20600 MM

RA = 3 (W) L1 / 8 148028.4375 174226.9375 KGS


RC = 3 (W) L1 / 8 148028.4375 174226.9375 KGS
RB = 5 (W) L1 /4 493428.125 545825.125 KGS
TOTAL 894279 KGS
ALTECH INFRASTRUCTURE PVT. LTD.
JOB NO ALT-285
EQUIPMENT DEAERATOR & FEED WATER STORAGE TANK
TITLE WIND AND SEISMIC LOAD CALCULATION REV. 0

FABRICATOR : ALTECH INFRASTRUCTURE PVT LTD.

CLIENT : THERMAX LIMITED

DESIGN CODE : ASME SECTION VIII DIV 1, EDITION 2015

CHAMBAL FERTILIZERS AND CHEMICALS LTD. OFFSITE & UTILITIES FOR CFG3
PROJECT TITLE : PLANTS

DESCRIPTION : WIND AND SEISMIC LOADS

Page 1 of 3
ALTECH INFRASTRUCTURE PVT. LTD.
JOB NO ALT-285
EQUIPMENT DEAERATOR & FEED WATER STORAGE TANK
DRG. NO. WIND AND SEISMIC LOAD CALCULATION REV. 0

VESSEL PARAMETERS
DEAERATOR DETAILS
Outside Diameter of Deaerator DA = 3000 mm
TL to TL of Deaerator DL = 13106 mm
Length overheads for deaerator OHD = 14606 mm
Deaerator Insulation thk DTINSU = 75 mm
Deaerator Height HT1 = 3394 mm
STORAGE TANK DETAILS
Outside Diameter of Storage tank DST = 4400 mm
TL to TL of Storage tank STL = 35331 mm
Storage Tank Insulation thk STTINSU = 75 mm
Storage tank height HT2 = 5088 mm
Length overheads for storage tank OHST = 37531 mm
Distance bet. saddle base to center of tank of storage tank B = 2738 mm
Saddle height RB = 2176 mm
Base plate length Lbp = 4400 mm
Shape factor for vessel (Depend on Hieght/breadth ratio) Cf = 0.7

CENTER OF GARAVITY OF VESSEL


In Empty Case :-
Empty weight of Deaerator W1 = 9800 kg
Empty weight of Storage tank W2 = 27850 kg
Total Empty Weight = W1 + W2 WE = 37650 kg
Centroidal distance from bottom of Deaerator C1 = 5542.8 mm
Centroidal distance from bottom of Storage tank C2 = 1950 mm
Center gravity for the tank in Empty condition y = 2885.17769 mm

In Operating Case :-
Operating weight of Deaerator W1 = 15300 kg
Operating weight of Storage tank W2 = 109890 kg
Total Operating Weight = W1 + W2 Wo = 125190 kg
Centroidal distance from bottom of Deaerator C1 = 5542.8 mm
Centroidal distance from bottom of Storage tank C2 = 1950 mm
Center gravity for the tank in Operating condition y = 2389.0913 mm

In Test Case :-
Test weight of Deaerator W1 = 23913 kg
Test weight of Storage tank W2 = 144580 kg
Total Test Weight = W1 + W2 WT = 168493 kg
Centroidal distance from bottom of Deaerator C1 = 5542.8 mm
Centroidal distance from bottom of Storage tank C2 = 1950 mm
Center gravity for the tank Test condition y = 2459.90027 mm

WIND LOAD DATA AS PER IS 875 (Part-3)


Basic wind speed Vb = 39 m/s
Design wind pressure Pz = 166 kgf/m²

Calculation of Wind force acting along X - Axial direction


Area exposed in axial direction for Deaerator (In Horizontal Position) Ad = 7.0695 m²
Area exposed in axial direction for Storage tank Ast = 15.2073 m²
Area exposed for saddle = RB * Lpb Asd = 9.5744 m²

Page 2 of 3
Area exposed for supports, nozzles & platform = 0.3 * (Ad + Ast + Asd) Am = 9.5554 m²
Total area exposed in axial direction = (Ad + Ast + Asd + Am) Ae = 41.4065 m²
Wind force acting in axial direction = Pz * Cf * Ae Fx = 4811.4393 kgf

ALTECH INFRASTRUCTURE PVT. LTD.


JOB NO ALT-285
EQUIPMENT DEAERATOR & FEED WATER STORAGE TANK
DRG. NO. WIND AND SEISMIC LOAD CALCULATION REV. 0

Calculation of Wind force acting in Z - transverse direction


Area exposed in transverse direction for Deaerator Ad = 43.818 m²
Area exposed in transverse direction for Storage tank Ast = 165.1364 m²
Area exposed for supports, nozzles & platform = 0.3 * (Ad + Ast) Am = 62.6863 m²
Total area exposed in axial direction = (Ad + Ast + Am) Ae = 271.6407 m²
Wind force acting in transverse direction = Pz * Cf * Ae Fz = 31564.6517 kgf

SEISMIC LOAD DATA IS- 1893 RCM


Importance Factor I = 1.5
Soil
Seismic Zone Factor
Type [For zone Number 2] Z = 0.1
= Medium Soil
Response reduction factor (Force factor) R = 3
Time Period of Vibration 0.0303 Sec
Damping Value
[Ignore the damping factor, assuming that the Site Spectrum specified is per the actual damping value 1
given by client for this vesel, The damp value is used as 1]
Value of Sa/g from user Spectrum Data 1.0108
Horizontal Seismic Coefficient Ah = Z/2 * min( I/R , 1.0 ) * Sa/g * DampValue
Provided that for any structure with T ≤ 0.1 s, the value of Ah will not be taken 0.05
less than Z /2 whatever be the value of I/R.
Seismic load acting in X-axial direction due to base shear Fx = 76082.6 kgf
(Data from P.V.Elite)
Seismic load acting in Z-transverse direction due to base shear Fz = 38041.3 kgf
(Data from P.V.Elite)

WIND & SEISMIC LOADS


FORCES MOMENTS
LOADING SUPPORT Fx Fy Fz Mx My Mz
CONDITIONS
Kgf ( ± ) Kgf( - ) Kgf ( ± ) Kgf-m (±) Kgf-m (±) Kgf-m (±)
FIXED 0.0 184,246.5 0 0 0 0
TEST
SLIDING 1 0.0 184,246.5 0 0 0 0
WIND (EMPTY FIXED 206.1 18825 1,400.1 4,039.5 0 594.6
CONDITION) SLIDING 1 0.0 18825 1,400.1 4,039.5 0 0.0
SEISMIC FIXED 2207.8 62595 7,877.6 18,820.3 0 5,274.6
(OPERATING
CODITION) SLIDING 1 0.0 62595 7,877.6 18,820.3 0 0.0

Page 3 of 3