Name PALMETTO PARK RD & MILITARY TRAIL Mod. No. 8 Initial Operation Date 10/26/1997 Intersection 106 Mod. Date 05/19/15 Part I Actuated Timing Information Non-coordinated Operation Phase 1 2 3 4 5 6 7 8 Sp(A) Sp(B) Approach EBLT WB SBLT NB WBLT EB NBLT SB Initial 7 18 7 12 7 18 7 12 Passage 1.8 2.0 1.8 2.0 1.8 2.0 1.8 2.0 Max1 35.0 70.0 25.0 45.0 30.0 70.0 20.0 45.0 Max2 Yellow 5.1 5.1 4.4 4.4 5.1 5.1 4.4 4.4 All Red 2.5 2.5 3.0 3.0 2.5 2.5 3.0 3.0 Walk 7.0 7.0 Ped Clear 27.0 27.0 Recall Min Min Flash Out In Out In C.N.A X X Dual Entry X X X X Walk Rest X X Flash Pat RED RED RED RED RED RED RED RED Detector Switching LT Type Prot Prot Prot Prot No Detect Type VDS VDS VDS VDS VDS VDS VDS VDS Pre-emption EVP-Opticom Active RailRoad Pre-Emption Active Fire Station Pre-emption Active Time B4 Trk Cl R Time B4 Bridge Active Phases Min Dwell Phases Min Dwell Trk Cl G Active Ph Active Ph Trk Cl Y Return Ph Return Ph Part II Coordinated Timing Information Pattern Tables PHASE 1 2 3 4 5 6 7 8 Cycle Offset Split Pat 1 19 42* 19 40 19 42 19 40 120 61 Split Pat 2 19 42* 19 40 19 42 19 40 120 61 Split Pat 3 MD 20 45* 25 40 20 45 24 41 130 118 Split Pat 4 20 49* 23 40 20 49 23 40 130 89 Split Pat 5 AM 42 45* 22 51 20 67 28 45 160 45 Split Pat 6 PM 19 72* 27 42 33 58 22 47 160 89 Schedule Implementation Schedule Notes Day Plan 1 (WEEKDAYS) Day Plan 2 (WEEKENDS) Day Plan 3 (Special) Start End Split Start End Split 0:00 7:00 50 0:00 7:30 50 7:00 7:30 30 7:30 9:00 100 7:30 9:30 5 9:00 18:00 3 9:30 15:30 3 18:00 19:00 28 15:30 18:00 6 19:00 22:00 27 18:00 19:00 31 22:00 0:00 50 19:00 22:00 26 22:00 0:00 50 Part III Network Information Equipment Manufacturer Comm Status Equiptment Manufacturer Comm Status GigE Switch N/A N/A UPS N/A N/A Switch 1 Etherwan Online Video Detection Iteris Online Switch 2 N/A N/A Pre-Emption Opticom N/A Video Encoder Vbrick/Vicon Online Other___________ Controller Naztec Offline Other___________ Part IV Notes and Comments 1. Mod 7: changed "Walk" time from 5 seconds to 7 seconds (phase 4 and phase 6). 2. Mod 7: adjusted split times for Pattern 3. 3. Mod 8: Updates yellow and all red time according to 2015 FDOT TEM standards