Industrial Measurement and Control

Instrumentation
For All Your Process Needs

Process Control
Analytical Measurement
Field Measurement

Controllers

Programmers

Indicators
Recorders & Data Acquisition

Hybrid Control Solutions

Actuators
Software Tools

Smart Sensors
Analytical Instruments

Field Instruments
Pressure and Level Solutions

Smartline transmitters are available for the • ST 3000 Series 100 are for the most demanding performance
widest range of pressure, differential applications.
pressure and liquid level measuring • ST 3000 Series 900 complement Series 100 units for
applications. Based on patented applications requiring smart performance at conventional prices.
piezo-resistive sensor technology, • ST 2000 pressure transmitters are for "fit and forget", non-smart
ST 3000® transmitters introduced pressure applications.
the concept of smart transmitters
in 1983 and have been constantly
improved to offer the ultimate in smart
features. They enable faster plant start-up and
change-over, reduced maintenance costs, more efficient $
S100
High Performance

operations and flexibility for improvements in control strategy.


S900
Not all applications require the highest performance, so Smartline Universal Smart
ST 2000
pressure transmitters have been made available in a tiered
Performance
family structure:

Differential Pressure (DP) Liquid Level (LL)

A complete range from 0-1 mbar to 0-210 bar. A complete range (flange-mounted) from 0-25 mbar
ST 3000: • Series 100: STD 1XX, to 0-7 bar.
from 0-1 mbar to 0-210 bar ST 3000: • Series 100: STF 1XX, from 0-25 mbar
• Series 900: STD 9XX, to 0-7 bar
from 0-25 mbar to 0-210 bar • Series 900: STF 9XX from 0-25 mbar
to 0-7 bar

Remote Seals (RS)

Gauge Pressure (GP) A complete offering of chemical seals for pressure


measurement (differential, gauge, absolute).
A complete range from 0-130 mbar to 0-461 bar.
ST 3000: • Series 100: STG 1XX,
from 0-350 mbar to 0-415 bar
• Series 900: STG 9XX,
from 0-1.4 bar to 0-415 bar
Special
ST 2000: • Series 2000: STG 20X,
from 0-200 mbar to 0-461 bar
ST 3000: • Series 100: STG14T & STG14F from
0-63 mbar to 0-35 bar with a variety of
process connections to operate with an
extended process temperature limit up
to 150°C.
Absolute Pressure (AP)

A complete range from 0-67 mbar Abs to 0-35 bar Abs.


ST 3000: • Series 100: STA 1XX, from 0-67 mbar Pressure
Abs to 0-35 bar Abs
• Series 900: STA 9XX, from 0-67 mbar ST 3000: • Series 900: STG93P from 0-0.3 bar to
Abs to 0-35 bar Abs 0-7 bar with a 1" pipe mount to avoid
ST 2000: • Series 2000: STA 2XX, from 0-0.2 bar pipe blockages in Pulp & Paper or
Abs to 0-11.5 bar Abs slurry applications.

4
Feature Performance Smart Family Size Reference Safety Approvals Output /
Accuracy Communications
(% of span) Protocols
Family

ST 3000 Series 100 Highest accuracy, Yes – fully 29 models – DP, GP, Analog mode: LCIE 4-20 mA / DE, HART,
stability & AP, LL, RS +- 0.075% FM/CSA fieldbus
widest range Digital mode:
+- 0.0625%
ST 3000 Series 900 Very good Yes – fully 17 models – DP, GP, Analog mode: LCIE 4-20 mA / DE, HART,
AP, LL, RS +- 0.1% FM/CSA fieldbus
Digital mode: +-
0.075%
ST 2000 Average No 11 models – GP, AP 0.2% Cenelec 4-20 mA / None
EEx ia IIB T4 /T5/T6

WIDE RANGE OF ACCESSORIES

Communicators Smartline Indication Meters (RMA 3000)


The Smart Field Communicator (SFC ) and the U275 HART
®
Analog and digital indication meters can be installed either within
communicator are handheld configuration tools approved the Smartline transmitter or separately mounted in a Remote Meter
intrinsically safe for use in the field or at control room interfaces Assembly (RMA) anywhere along the transmitter wiring route.
to talk to the Smartline transmitter, to check or change its They give both a numerical and bar graph display of the measured
configuration, to monitor its operation, to calibrate and to value together with engineering units and loop status.
diagnose/troubleshoot. The Smart Configuration Toolkit (SCT 3000)
is the PC tool version of the SFC. Manifolds and Primary Elements
For the isolation, calibration, testing and venting of instruments,
Fieldbus Configuration Tools two-, three- and five-way manifolds are available, with a variety
TPS Builder R120 provides a user-friendly PC interface for of inlet and outlet port sizes. A large choice of primary elements
configuration of fieldbus instruments and applications operating on is also available, including Pitot tubes, (also as a complete
Honeywell’s TPS System High-Performance Process Manager® solution with the SMV 3000), venturi, orifice elements and
R610. When the host system is PlantScape, or if a portable configu- laminar flow elements.
ration tool is required, the National Instruments fieldbus configurator
provides compatibility across a range of fieldbus suppliers’ devices Options
for configuring, scheduling, maintaining and even acting as All transmitters are supported by a large portfolio of options
the communications Link Master for off-line workshop activities. and accessories. These include: corrosion-resistant materials;
surge and lightning protectors; piping adapters and manifold
Chemical Seals connection blocks; stainless steel tagging; and low temperature
In some processing applications it is necessary to isolate the operation (-50°C).
pressure measuring instrument from the process in order to
maintain accuracy and reliability objectives. Honeywell’s chemical
seals are specially designed for this purpose.

5
Temperature Solutions

The STT 3000 family of Smart Temperature


Transmitters comprises three Series of
units to match every field-mounting
temperature measurement appli-
cation. All Series have an extensive
library of ThermoCouple (TC) and
Resistance Temperature Detector
(RTD) temperature sensor types,
High Performance
enabling minimum spares holding and STT350

$
flexibility for future control strategy changes. Universal Smart
STT250

Programmable
STT150

Performance

STT350 STT150

The STT350 offers the highest performance The STT150 is the smallest, lowest cost unit,
and has the largest sensor library, making it an economical replacement for
with a host of features including redundant compensation wire by installing it directly in
thermocouple input, differential temperature the smallest DIN sensor head and giving
measurement, internal/external cold junction immediate investment payback for wiring
compensation and suitability for digital runs over 80 meters.
integration with its DE or fieldbus communications.

STT250

The STT250 offers a low installation


cost thanks to its direct sensor head
mounting design.

8
Feature Performance Smart Sensor Library Communications Protocols

Family

STT350 Highest accuracy Yes – fully T/Cs types B,C,D,E,J,K,N,R, S,T, 4-20 mA, DE,

(e.g. +/- 0.1°C for Pt100), Ni/NiMo.RTDs : Pt100/200/500/ fieldbus

stability and widest range 100J, Cu10/25, Ni500

Radiamatic, mV, Ohms

STT250 Very good Yes – fully T/Cs types B,E,J,K,N,R,S,T 4-20 mA, DE, HART

(+/- 0.15°C for Pt100) RTDs : Pt100/200/100J

mV, Ohms

STT150 Good No – programmable T/Cs types B,E,J,K,N,R,S,T 4-20 mA

(0.5°C for Pt100) RTDs : Pt100 / 200 / 100J

mV, Ohms + custom

WIDE RANGE OF ACCESSORIES

Communicators Sensors and Thermowells


The handheld SFC and PC based SCT 3000 tools fully support STT 3000 transmitters are available with the full spectrum
the STT 3000 4-20 mA and DE family members together with the of temperature sensors and screwed or flanged thermowells
other Smartline ST 3000, SMV 3000 and Smart MagneW PLUS to meet your exact requirements. They can be delivered as
transmitters. STT150 configuration is by the SCT 3000 software a complete thermal solution.
but uses a dedicated high-speed/economic cost RS-232
connector. The U275 HART communicator is also available. Surge and Lightning Protectors
Both integrally mounted and external surge protector models are
Fieldbus Configuration Tools designed to give maximum protection against surges such as those
TPS Builder R120 provides a user-friendly PC interface for caused by lightning strikes.
configuration of fieldbus instruments and applications operating on
Honeywell’s TPS System High-Performance Process Manager R610. Other Accessories
When the host system is PlantScape, or if a portable configuration Whatever your needs, STT 3000 transmitters will satisfy them,
tool is required, the National Instruments fieldbus configurator with an extensive selection of housings, indicators, certifications
provides compatibility across a range of fieldbus suppliers’ devices and adapters.
for configuring, scheduling, maintaining and even acting as the
communications Link Master for off-line workshop activities.

9
Controllers, Programmers and Indicators

CONTROLLERS UDC 100 UDC 700 UDC 1000

Product Description The UDC 100 is a 1/4 DIN temperature The UDC 700 is a 1/32 DIN format, OEM The UDC 1000 provides a high degree of
controller designed for low cost/high controller designed for a large number of functionality and reliability in a small format
performance applications. An optional timer applications. (1/16 DIN) at a very low price. A limit
is also available. control model is also available.

Front Face Format 96 x 96 mm (3.78 x 3.78") 49 x 25 mm (1.93 x 0.98") 48 x 48 mm (1.89 x 1.89")

Analog Inputs 1 or 2 low levels 1 1

Input Signal Types Thermocouples, RTDs, mV, mA Thermocouples, RTDs, mV, mA Thermocouples, RTDs, mV, mA

Digital Inputs N/A N/A 1

Analog Outputs (Pending) N/A Up to 3

Digital Outputs Control Up to 2 Up to 2 Up to 2

Digital Outputs Alarm 1 Up to 2 Up to 2

Accuracy (at ref. cond.) ± 0.5% of F.S. ± 0.1% of span ± 0.25% of span

Loops Up to 2 1 1

Networking N/A RS485 Modbus RS485 ASCII or Modbus

Honeywell controller value: Every Honeywell Controller,


Programmer and Indicator offers you
■ Clear and informative operator interface the best price/performance ratio
compared with any competitive
■ Easy to setup and operate instrument in its class. Our complete
■ Straightforward installation and maintenance line of Controllers, Programmers and
Indicators is engineered to provide
■ Single-button tuning for precise control you with "targeted functionality" –
solutions tailored to your specific
■ Fuzzy logic overshoot suppression process control requirements – so
■ Unsurpassed quality and support you only buy what you need.

6 w w w . h o n e y w e l l . c o m / i m c
UDC 1500 UDC 2300 UDC 3300 UDC 6300

The UDC 1500 is a 1/8 DIN microproces- The UDC 2300 is a low-cost digital The UDC 3300 is a 1/4 DIN general- The UDC 6300 Process Controller, with
sor-based controller. It provides high controller providing multi-language prompts purpose digital controller offering a high both vertical bar graph and digital display
quality and performance at low cost. (FR, EN, GE, IT, SP) and code for degree of functionality and operating features, is ideal for continuous process
unmatched operating simplicity. simplicity. It now offers multi-language applications.
prompts, Basic Math, 2 loops operation
and HealthWatch diagnostic software.

48 x 96 mm (1.89 x 3.78") 96 x 96 mm (3.78 x 3.78") 96 x 96 mm (3.78 x 3.78") 72 x 144 mm (2.83 x 5.67")

1 1 high level, 1 low level 2 low levels, or 1 low level and 4 high levels, 1 low level
2 high levels

Thermocouples, RTDs, mV, mA Thermocouples, RTDs, mV, V, mA, RH, Thermocouples, RTDs, mV, V, mA, RH, 4 to 20 mA, 10 to 50 mA, 1 to 5 V T/C,
N/A Radiamatic Radiamatic, carbon, oxygen RTDs, mV, V, mA, RH

1 1 (4 selections) 2 Up to 6

Up to 3 2 (4 to 20 mA and 1 to 5 V) 2 (4 to 20 mA) 2 (4 to 20 mA)

Up to 2 Up to 2 Up to 2 Up to 2

Up to 2 Up to 2 Up to 2 Up to 4

± 0.25% of span ± 0.25% of span ± 0.2% of span ± 0.05% of span

1 1 2 2

RS485 ASCII or Modbus RS422/485 ASCII or Modbus RTU RS485 ASCII or Modbus RTU or DMCS RS485 ASCII or Modbus RTU or DMCS

ACCUTUNE™ II WITH FUZZY LOGIC


Aggressive Retuning – Easy Solutions (Available on the UDC 2300, 3300 and 6300)
Accutune™ II provides a new truly plug-and- Accutune adaptive tuning algorithm that can independently from Accutune tuning. It does not
play tuning algorithm which will, at the touch of a automatically and continuously retune whenever a change PID constants, but temporarily modifies the
button or through a digital input, accurately setpoint step change is implemented or whenever internal controller response to suppress overshoot.
identify and tune any process including integrating a process variable disturbance occurs. This allows more aggressive tuning to co-exist with
processes and those with deadtime. This speeds Fuzzy logic is used to suppress process variable smooth process variable responses. It can be
up and simplifies startup, plus allows retuning at overshoot due to setpoint changes or externally enabled or disabled depending on the application
any setpoint. Also included is the original induced process disturbances. It operates or the control criteria.

Detects and Adapts to


Disturbances
PV
SP Value
Adapts to Process Dynamics
Illustration of 3
Typical Problems Start-Up Mode
Resolved By Prevents Overshoot
ACCUTUNE
Time

w w w . h o n e y w e l l . c o m / i m c 7
Recorders and Data Acquisition
Strip Chart recorders are most commonly chosen for continuous processes where the chart record allows the operator to quickly detect
out-of-tolerance deviations over a long-term trend. The long length of the strip chart allows recorders to run unattended for long
periods without the necessity for frequent chart replacement.

STRIP CHART
RECORDERS DPR100A/B DPR100C/D DPR180 DPR250

Display Analog Digital Digital Digital

Paper Width 100mm (3.94 in.) 100mm (3.94 in.) 180mm (7.09 in.) 250mm (9.84 in.)

Reference Accuracy 0.25% 0.10% 0.05% 0.05%

Multipoint Channels 6(DPR100B) 6(DPR100D) 24 64

Continuous Pens 1-3(DPR100A) 1-3(DPR100C) N/A N/A

Roll or Fan-Fold Charts Yes Yes Yes Yes

Configuration PC or Keyboard PC or Keyboard PC or Keyboard PC or Keyboard

Data Storage N/A N/A PCMCIA PCMCIA

Networking N/A ASCII, Modbus ASCII, Modbus ASCII, Modbus

Optional Software N/A LPCS LPCS; SDA LPCS; SDA

Circular Chart recorders, in general, are preferred for batch processes. The circular chart record displays the entire batch operation
over a specific unit of time, from one hour to 31 days. An additional advantage of the circular chart record is easy filing and copying
for reference. Compared to the strip chart record, the circular chart has a shorter calibrated chart width.

CIRCULAR CHART
RECORDERS DR4300 Basic DR4300 DR4500 Classic DR4500 Truline

Chart Size 10 in. (254 mm) 10 in. (254 mm) 12 in. (305 mm) 12 in. (305 mm)

Reference Accuracy 0.35% 0.10% 0.10% 0.10%

Analog Inputs 2 2 2 4

Digital Display N/A Yes Yes Yes

Chart Type Preprinted Preprinted Preprinted Self-printing

Control N/A 2 loops 2 loops 2 loops

Math N/A Totalization Yes Yes

Networking N/A Modbus RTU Modbus RTU Modbus RTU

Optional Software N/A SpecView SpecView SpecView

w w w . h o n e y w e l l . c o m / i m c 9
Recorders and Data Acquisition

PAPERLESS RECORDERS eZ Trend Teletrend V5 Minitrend V5 Multitrend V5

Displays 5.0” (127 mm) Color 5.5” (140 mm) Color TFT 5.5” (140 mm) Color TFT 10.4” ( 264 mm) Color TFT

Analog Inputs 2,4,6 2,4,6,8 4,6,8,12,16 6,8

Data Storage 1.44mB Floppy 1.44mB Floppy 120mB Floppy, Flash card 1.44mB Floppy

Sample Rate 100 ms 125ms Std. Inputs 20ms 125ms Std. Inputs

Digital I/O Up to 2DI/6DO Up to 8DI/8DO Up to 16DI/16DO Up to 8DI/8DO

Networking RS-485 ASCII or Modbus RTU RS-485 ASCII or Modbus RTU RS-485 ASCII, Modbus, Ethernet RS-485 ASCII or Modbus RTU

Math 200 character free form math 60 character free form math 200 character free form math 60 character free form math

Reference Accuracy 0.15% 0.5% 0.5% 0.5%

Configuration PC or front panel PC or front panel PC or front panel PC or front panel

Control No No No No

Honeywell’s TrendManager ■ Archive data on integral secure


database The Paperless Advantage
Software Suite
■ E-mail configurations and data Easy to Use - Dedicated display keys and full screen
The TrendManager Software Suite
■ Event systems analysis menus allow operators to quickly access and interpret
includes the standard Trendviewer
software package; the Trendmanager Trendserver Pro — includes all of the information.
Pro advanced data analysis and capabilities of Trendmanager Pro, plus:
Improved Decision Making - On-line data analysis
archiving software; the Trendserver Pro ■ FTP (File Transfer Protocol)/Ethernet
fully network aware software for allows fast operator response during process upsets.
connection (TCP/IP)
communications with recorders; and the ■ Web browser access Meet Documentation Requirements - Permanent
Screen Designer software for creating ■ Audit trail manager and multi-level archived records of process and configuration data can be
customized screen layouts. This low- password system complies with 21 stored to disk and easily replayed on the recorder or
cost, flexible, easy-to-use software suite CFR part 11 personal computer using the data analysis software.
sets the “-trend” recorders apart from all ■ Distribution of data over LAN (Local
the others! Access Network) Easy to Operate and Maintain - Reduced maintenance
■ Export using OPC links costs, elimination of consumable pens and paper and
Trendviewer
■ View, graph and print stored data Screen Designer increased reliability since mechanical print assemblies
■ Export data files in CSV format ■ Total design flexibility to produce the have been eliminated.
■ Print out data and configurations ultimate in customized screen layouts Easy to Own - Paperless recorders offer significant
■ Screens that are sure to meet improvements over traditional paper recorders. Their
TrendManager Pro — includes all of
operators’ needs
the capabilities of Trendviewer, plus: inexpensive storage media and full-color LCD display
■ Design the screen that will best
■ Full configuration of Mini/Multi/Tele/ reduces operating costs and improves data analysis. The
monitor your process
CirciTrend recorders lack of vulnerable print mechanisms and other mechanical
■ Totally unique to the marketplace
parts improves reliability.

10
PAPERLESS RECORDERS Multitrend Plus V5 Circitrend V5 VRX 180

Displays 12.1” (307 mm) Color TFT 10.4” (264 mm) Color TFT 10.4” (264 mm) LCD Color

Analog Inputs 8,12,16,24,32 2,4,6,8 48

Data Storage 120mB Floppy, Flash card 1.44mB Floppy Yes

Sample Rate 20ms 250ms Std. Inputs 4 channels @ 250ms

Digital I/O Up to 32DI/32DO Up to 8DI/8DO Up to 36DI/36D0

Networking RS-485 ASCII, Modbus, Ethernet RS-485 ASCII or Modbus RTU Modbus

Math 200 character free form math 60 character free form math 64 calculation blocks

Reference Accuracy 0.5% 0.5% ±.05%

Configuration PC or front panel PC or front panel PC-based software (SCF)

Control No No Yes-8 loops

Electronic data acquisition instruments are the


perfect solution for applications within the
Power, Water Treatment, Thermal Processing,
Minitrend
Food & Beverage, Pharmaceutical/Biotech, and
Web Browser Manufacturing industries. U.S. regulatory
agencies have accepted electronic data
storage. Title 21 CFR Part 11 of Federal
Regulatory Affairs details the acceptability of
Quality Dept. Plant Wide electronic records.
Local Area
Network Multitrend Plus

Easy to Network
Maintenance Dept. Products can be connected directly to the
Local Area Network (LAN) using the Ethernet
TCP/IP Modbus protocol. Using the LAN,
Local Instrument various departments can access these instru-
Minitrend
Networks
Minitrend Multitrend Plus
ments for real time data acquisition.
Minitrend
Trend Server Trend Manager
Pro Software Pro Software

w w w . h o n e y w e l l . c o m / i m c 11
Hybrid Control Solutions

The HC900 Hybrid Controller offers an integrated solution that cost-effectively


performs loop and logic control of stand-alone, small to medium sized unit
processes. Up to 32 analog control loops, eight setpoint programs, function
block configuration, data acquisition and an extensive assortment of predefined
analog and digital blocks make the HC900 the ideal choice for thermal
processing, water treatment, food & beverage processing, power generation,
pharmaceutical, manufactured goods, semiconductor industries and other
processes with similar control requirements.
The HC900 consists of three components: a powerful controller with modular
I/O; a hardened operator interface with color display and optional disk drive;
and intuitive configuration software.

HC900 HYBRID CONTROLLER


Controller:
■ Modular I/O design
■ Multiloop PID Control
■ Setpoint programmers, scheduler
■ Process logic, timers, counters
■ Process algorithms, calculations Maintenance Dept. Quality Dept. Operations
■ Universal analog inputs
■ Stores setpoint profiles, recipes

Operator Interface:
■ Control loop supervision
■ Load/monitor setpoint programs, recipes
■ View analog & digital status Ethernet
■ View bar graph groups
■ View trends
Open
■ View alarm and event status Connectivity
■ Initiate operator pushbutton actions
■ Optional data storage to floppy disk
■ Type 4X HC900
HC900 Unit Control
Unit Control

Hybrid Control Designer Software:


■ Windows NT, 2000 or Me
■ Drag & drop soft wiring of function
block objects
■ Configures operator displays
HC900 Data HC900 Data HC900 Data
■ Load configuration via ethernet, serial Acquisition Acquisition Acquisition
communication or floppy disk
■ Graphic hard copy records
■ Load/upload, monitor configuration
via modem
HC900 - THE EASY CHOICE!
Communications: The versatile HC900 is the perfect solution for unit control requiring integrated
■ Ethernet 10baseT loop and logic processing. It is also the ideal data acquisition package with up to
■ Modbus/TCP protocol 256 universal analog inputs, extensive math and free form calculations. Intuitive
■ Up to 9 peer to peer controllers
function block software allows you to quickly get up and running, saving you time
and money. Ethernet Open Connectivity simplifies plant network integration.

12 w w w . h o n e y w e l l . c o m / i m c
Supervisory & Configuration Software

A COMPLETE RANGE
OF SOFTWARE TOOLS
FOR CONFIGURATION
AND ANALYSIS.

LPCS
LeaderLine™ Personal Computer Software
SDA (LPCS) is a low-cost and easy-to-use Windows
The Software Data Analysis (SDA) package based application designed for device
provides powerful PC based recorded data configuration, operation, monitoring and archiving.
analysis of archived information stored on the Devices currently connectable to LPCS are
VRX180 and UMC800. Data histories can be UDC2300, UDC3300, UDC6300, DPR100 C/D,
displayed and compared for identification of DPR180 and DPR250. Communication is RS485-
process upsets and trends. Alarms, events and ASCII for up to 16 devices at 19.2K maximum
diagnostics can also be displayed. Data security baud rate.
is maintained by converting trend files to .CSV
files for export to common spreadsheet packages. HAL
The Honeywell Actuator Linkage software helps
SCF you accurately size, select and install your
SCF is a configuration software package Honeywell actuator. The software lets you choose
designed to configure VRX180 recorders. The the actuator and design the linkage that best fits
configuration is done in a tabular function block your application.
format.

TrendManager Suite
TrendManager Suite provides the ability to
configure, network and customize displays on the
Minitrend, Multitrend, Teletrend and CirciTrend
family of paperless recorders. Refer to page 10 for
more details.

SpecView 32 is a low cost, easy-to- use, centralized PC software that provides supervisory control, data acquisition, recipe manage-
ment and batch reporting. SpecView 32 operates in all current Windows operating systems environments - 98, Me, NT, XP, and 2000.
The optional OPC client capability allows easy linkage to other OPC server products. SpecView’s instrument view capability minimizes
database creation for easy configuration.

w w w . h o n e y w e l l . c o m / i m c 15
Herculine Electric Actuators – Easy To Own!

Herculine®
ELECTRIC ACTUATORS Herculine 2000 Herculine 2001/2002 HercuLine® 10260 HercuLine® 11280

Product Description Low torque electric actuator Low torque electric actuator Medium torque industrial electric High torque industrial electric
actuator actuator

Torque 50-400 in-lb (6-45 N-M) 50-400 in-lb (6-45 N-M) 10 - 300 lb-ft (14-400 N-M) 425 - 5,500 lb-ft (575 - 7500 N-M)

Stroke/Speed 90˚-160˚/15 to 240 sec 90˚ - 160˚/7.5 to 120 sec. 90˚/20/40/60 sec 90˚/10/30/60 sec

Input Signals 2-10 Vdc, 4-20mA 1 - 5 Vdc, 4 to 20 mA, Floating, 0/1-5 Vdc, 0/4-20 mA, Floating, 0/1 -5 Vdc, 0/4-20 mA, Floating,
Pos. prop., Open/Close Pos. prop., Open/Close Pos. prop., Open/Close

Position Feedback 1000/135 ohms over 90º 0/1-5 Vdc, 0-16V dc, 0/4-20 mA, 0/1-5 Vdc, 0-16V dc, 0/4-20 mA, 0/1-5 Vdc, 0-16V dc, 0/4-20 mA,
SW emulation SW emulation SW emulation

Position Sensing Slidewire 2001: slidewire Contactless Contactless


2002: contactless

Environmental -40 to 185˚F (-40 to 85˚C) -40 to 170˚F (-40 to 75˚C) -20 to 170˚F (-30 to 75˚C) -20 to 150˚F (-30 to 65˚C)

Duty Cycle Continuous Continuous Continuous Continuous

Repeatability N/A 0.2% of 90˚ span < 0.2% span < 0.2% span

Dead-Band Adj. 0.2% to 5% span Adj. 2% to 5% span Adj. 0.2% to 5% span Adj. 0.2% to 5% span

Local Auto/Man Switch Optional Optional Optional Optional

Local Keypad/Display N/A Optional 10260S: Optional 112805: Optional

RS485 Modbus Comms. N/A Yes 10260S: Yes 112805: Yes

Honeywell’s HercuLine® Electric Actuators are HercuLine® Smart Actuators


engineered for exceptional reliability, accurate Honeywell’s new actuators incorporate all of the
positioning, and low maintenance. Designed for quality and reliability features of the Herculine
very precise positioning of dampers and quarter- actuators with the added benefits of
turn valves, they perform especially well in microprocessor-based electronics. These benefits
extremely demanding environments requiring make it easier to install, set up and commission
continuous duty, high reliability, and low mainte- the actuator, while allowing you to monitor the
nance. With non-contact sensing, the main- health parameters for proactive maintenance
tenance problems and unexpected shutdowns planning.
associated with slidewires and potentiometer ■ RS485/Modbus communications for
wear are eliminated. remote access
■ Programmable:
State-of-the-art control systems require ✓ Alarm and relay outputs
HercuLine® Palm Software lowers cost of ✓ Characterization, failsafe functions,
accurate, responsive, and repeatable
ownership dead-band, and filtering
■ Use your Palm PDA for actuation of final control devices to
✓ Direction of rotation
✓ Calibration operate with maximum efficiency and ■ Diagnostic Parameters:
✓ Configuration improve process control. Actuators are ✓ Maximum Hi and Lo temperature
✓ Maintenance data often overlooked when considering the ✓ Stall and accumulated stall time
■ Eliminates local display and keypad performance of a control system. Com- ✓ Total travel
bined with maintenance and ancillary
support costs, they will directly impact
your company’s bottom line.
16 w w w . h o n e y w e l l . c o m / i m c
Industrial Measurement and Control

Dissolved
Oxygen

pH

Made Easy
with ®

DirectLine
Measurement Architecture
• Easiest to Install - eliminates long cable runs & panel cutouts
• Easiest to Use - local calibration and display
• Easiest to Maintain - ‘plug & play’ sensors

DirectLine Sensors are the Durafet® Non-glass pH Electrodes


Best Value for Analytical • Most stable
Measurements in Wastewater
• Fastest response
Applications, Combining Low
Installed Cost with Ease of Use.
• Broadest temperature range

Equilibrium DO Probes
• Not flow-sensitive
Visit our web site to get product details and • Unaffected by Fouling
enter a drawing for a free DirectLine evaluation unit • Permanent probe
components
with your choice of pH or DO probe.
www.honeywell.com/imc/promo/E13

Analytical Sensors Controllers Data Acquisition Actuators Transmitters

Industrial Measurement and Control


http://www.honeywell.com/imc • 1-800-784-3011
Honeywell offers a full line of easy to use control products available from local representative world wide. Copyright © 2003 Honeywell International, Inc.
SGS 201 SGS 410 SGS 406
SUBMERSIBLE TRANSDUCERS General Purpose Level Borehole Level Borehole Level
Accuracy (BSL) ±0.1% BSL ±0.2% BSL ±0.1% BSL

Hydrostatic Pressure– 10 to 750 feet, 10 to 750 feet, 10 to 750 feet,


Feet or Meters (0 to ...) 1 to 170 meters 4 to 170 meters 4 to 170 meters

Overpressure & Burstpressure x 2 NIR and x 4 NIR x 2 NIR and x 4 NIR x 2 NIR and x 4 NIR

Output voltage: 3 wire 1-5V 0.4-2V 0-5V 0-10V - -


4 wire 0-100mV 0-1V 0-100mV 0-50mV

Supply Voltage 9-36Vdc (12-36V for 0-10V FS) 7-35Vdc 4-35Vdc

Supply Voltage Variation Effect 0.01% FS per Volt 0.01% FS per Volt 0.01% FS per Volt

Span Adjustment Range 25-125% NIR 0.01% FS per Volt 0.01% FS per Volt

Zero Adjustment Range ±10% of set span Fixed Fixed

Temperature Operating Range -20˚C to + 70˚C (-4 to + 158˚F) -20˚C to + 70˚C (-4 to + 158˚F) -20˚C to + 70˚C (-4 to + 158˚F)

Temperature Effect 20˚C±30˚C Zero ±1% NIR Total ±2% NIR Zero ±1% NIR Total ±29% NIR Zero ±1% NIR Total ±29% NIR

Materials in Contact with the Media Stainless steel 316L, Nitrile rubber, Stainless steel 316L, Nitrile rubber, Stainless steel 316L, Nitrile rubber,
Polyurethane Polyurethane Polyurethane

Sealing IP68 IP68 IP68

Electrical Connection Flying lead Flying lead Flying lead

SUBMERSIBLE TRANSDUCERS SGS 601 AFA 801


4 - 20m Output General Purpose Level Borehole Level
Non Linearity Including Hysteresis ±0.15% BSL ±0.3% FS ±0.15% BSL ±0.3% FS
(best straight line)

Hydrostatic Press.– Ft. or Mtrs(0 to...) 10 to 750 feet, 4 to 170 meters 30 to 750 feet, 10 to 170 meters

Overpressure and Burstpressure x 2 NIR and x 4 NIR x 2 NIR and x 4 NIR

Output Current: 2 wire 4-20mA 4-20mA

Supply Voltage 9-43Vdc 12-36Vdc

Span Adjustment Range 25-125% NIR Fixed

Zero Adjustment Range ±10% span Fixed

Temperature Operating Range -20˚C to + 60˚C (-4 to + 140˚F) -20˚C to + 60˚C (-4 to + 140˚F)

Temperature Effect 20˚C±30˚C 0.06%/˚C 0.06%/˚C

Materials in Contact with the Media Stainless steel 316L, Nitrile rubber, Polyurethane Stainless steel 316L, Nitrile rubber, Polyurethane

Dimensions 144 x 380mm (5.67 x 14.96 in.) 84 x 210mm (3.31 x 8.27 in.)

Sealing IP68 IP68

Electrical Connection Flying lead Flying lead

w w w . h o n e y w e l l . c o m / i m c 23
Smart Sensors & Analytical Instruments

SIGNAL CONDITIONING PRESSURE TRANSMITTERS SGS 501 SGS 701


4 - 20mA Output General Purpose Boss Mounted
The SCU 2000 Offers:
Accuracy (BSL) ±0.15% BSL ±0.3% FS ±0.15% BSL ±0.39% FS
■ 2 wire 4-20mA output
■ Inputs from mV to V Gauge–PSI or Bar (0 to ...) 15 to 5000 psi, 0.4 to 350 bar 15 to 5000 psi, 0.4 to 350 bar
■ Operation to greater than Absolute–PSI or Bar (0 to ...) 5 to 250 psi, 0.4 to 27 bar 5 to 15 psi, 0.4 to 1 bar
2000Ω load Vacuum–PSI or Bar (0 to ...) 15 psi, 1 bar 15 psi, 1 bar
■ High noise immunity
Overpressure and Burstpressure x 2 NPR and x 4 NPR (max 2000 bar)
■ 8:1 span turn down x 2 NPR and x 4 NPR (max 1000 bar)
■ d.c. telemetry loop compatible Output Current, 2 wire 4-20mA 4-20mA
■ Two transducer supply voltages
Supply Voltage 9-43Vdc 12-36Vdc

Temperature Operating Range -20˚C to + 60˚C (-4 to 140 ˚F) -20˚C to + 60˚C (-4 to 140 ˚F)

Materials in Contact with the Media Stainless steel 316L Stainless steel 316L

Sealing IP68 IP68

Electrical Connection Flying lead DIN connector Flying lead DIN connector

PRESSURE TRANSDUCERS
MV AND VOLTAGE SGS 100 SGS 300 SGS 306
Output General Purpose Boss Mounted Boss Mounted
Non Linearity Including Hysteresis ±0.1% BSL ±0.2% BSL ±0.2% BSL
(best straight line)

Gauge–PSI or Bar (0 to ...) 5 to 5000 psi, 0.1 to 550 bar 15 to 2000 psi, 15 to 550 bar 15 to 2000 psi, 15 to 550 bar
Absolute–PSI or Bar (0 to ...) N/A 5 to 250 psi, 0.4 to 27 bar 5 to 250 psi, 0.4 to 27 bar
Vacuum–PSI or Bar (0 to ...) 15 psi, 1 bar 15 psi, 1 bar 15 psi, 1 bar

Overpressure and Burstpressure x 2 NPR and x 4 NPR (max 1000bar) x 2 NPR and x 4 NPR (max 1000bar) x 2 NPR and x 4 NPR (max 1000bar)

Output voltage 1-5V 0.4 - 2V 0-5V 0-10V (3 wire) - -


0-100mV 0-1V (4 wire) 0-100mV (4 wire) 0-50mV (4 wire)

Supply Voltage 9-36Vdc (12-36V for 0-10V FS) 7-35Vdc 4-35Vdc

Temperature Operating Range -20˚C to + 70˚C (-4 to 158˚F) -20˚C to + 70˚C (-4 to 158˚F) -20˚C to + 70˚C (-4 to 158˚F)

Materials in Contact with the Media Stainless steel 316L Stainless steel 316L Stainless steel 316L

Sealing IP68 IP68 IP68

Electrical Connection Flying lead Flying lead Flying lead

24 w w w . h o n e y w e l l . c o m / i m c
Accessories SCT 3000 Smartline Multi-Variable Analog H2Oil Analyzer System
Smartline Field Configuration Toolkit Interface (MVA) Designed for use in the
Communicator (SFC®) This PC-based tool The MVA provides an petroleum recovery
The SFC® reduces the allows quick, error-free interface between DE industry, the H2Oil Analyzer
time to install, configure, configuration of Smartline transmitters and System provides in-line,
and maintain Smartline® Smartline products. analog instrumentation, real time measurement of
instruments. ■ Access to such as safety shutdown percent water in oil. It
■ Hand-held device configuration database systems, trip switches, accurately measures the
communicates remotely parameters indicators, recorders, amount of water in
with all Smartline ■ Verifies all parameters backup or critical loop continuous-oil phase or
instruments are correct single-loop controllers, and continuous-water phase
■ Access to devices ■ Enables more. conditions through the
without entering "Management of ■ Robust, bumpless, and entire composition range of
hazardous areas Change" accurate communications 0% to 100% water.
■ Complete configuration ■ Microsoft Windows ■ Low-cost access to all ■ Superior, non-intrusive
and diagnosis of 95b, 98, NT (4.0), 2000 measured variables sensor design
Smartline devices and ■ Enables mix of DE and ■ Compensated for
control loops analog products temperature and salinity
effects
■ Tolerant to sand, grit, or
Multi-Variable Trip entrained gases
Switch (MTS) ■ 2” (50 mm), 3” (75 mm),
The MTS provides a 4” (100 mm), 6” (150
stand-alone safety mm), 8” (200 mm)
shutdown solution that models available
Honeywell MC Toolkit can range from simple
The Pocket PC-based shut-off of a pump or
Honeywell MC Toolkit motor to inclusion as part
handles multiple commun- of a large system solu-
ication protocols, letting you tion.
configure, monitor, diag- ■ Zero error digital PV trip
nose, and manage smart ■ Supports digital DE or
devices from Honeywell and analog inputs
other suppliers. ■ One or two relays, 5A
■ Configures both DE and @240VAC
HART protocols ■ Independent
■ Automatically verifies transmitter status relay
device identification and positively differentiates
database configuration maintenance from
■ Provides full self-diagnos- process problems
tic and device diagnostic ■ Optional analog repeat
support output

27

Das könnte Ihnen auch gefallen