Sie sind auf Seite 1von 4

ONE SOLUTION FOR ALL

GENSET APPLICATIONS
 Tailored for the most demanding applications,

D-700 the D-700 provides synchronization, load share,


mains synchronization, soft transfer, AMF, ATS,
Remote Start, Engine control and remote display
panel functionalities in a single unit,
AUTO LEARNING  Easy commissioning is achieved with the automatic
SYNCHRONIZATION learning feature, a first in the industry.
 Unequalled communication capabilities allow
CONTROLLER integration to virtually any management system.

FEATURES COMMUNICATION
• 4.3” 480x272pixels color LCD • Both CANBUS-J1939 & MPU • Ethernet (10/100Mb)
• Diesel and gas genset support • 3 configurable service alarms • 4-band GPRS modem (optional)
• Supports up to 48 gensets • Multiple automatic exerciser • USB Host & USB Device
• Automatic learning/self adjust • Weekly operation schedule • RS-485 (2400-115200baud)
• Direct governor & AVR control • Dual mutual standby with equal • RS-232 (2400-115200baud)
• Voltage and phase matching aging of gensets • Micro SD card slot
• kW & kVAr load sharing • Manual “speed fine adjust” on • J1939-CANBUS
• Multiple topologies selected ECUs • Geo-locating through GSM
• 6xCT, true mains metering • Automatic fuel pump control • GPS support (USB & RS-232)
• True soft transfer in both ways • Disable protections feature • Embedded web server
• Peak Lopping / peak shaving • Excess power protection • Web monitoring & programming
(mains or genset priority) • Overload IDMT protection • Internet Central Monitoring
• Mains de-coupling protection • Load shedding, dummy load • SMS message sending
• R.O.C.O.F protection • Multiple load management • E-mail sending
• Vector shift protection • Current unbalance protection • Free PC software: Rainbow Plus
• Reverse power protection • Voltage unbalance protection • Modbus RTU & Modbus TCP/IP
• Over/under freq. Protection • Fuel filling & fuel theft alarms • SNMP (with TRAP messages)
• Over/under voltage protection • Battery back-up real time clock • SNTP
• Smart load management • Idle speed control
• Smart genset sequencing • Battery charge run enabled FUNCTIONALITIES
• Run/stop priority support • Combat mode support • Multi genset synch & load share
• Equal aging of gensets • Multiple nominal conditions • Mains synchronization
• Base load (power export) • Contactor & MCB drive • Single genset parallel with mains
• Unmanaged distributed power • 4 quadrant genset power • AMF unit (uninterrupted transfer)
export support counters • ATS unit (uninterrupted transfer)
• AVR & GOV droop support • Mains power counters • Remote start controller
• Dead bus sensing • Fuel filling counter • Manual start controller
• 400Hz operation support • Fuel consumption counter • Engine controller
• 400 event logs, full snapshot • Modem & ethernet diagnostics • Remote display panel
• All parameters front panel • Configurable through USB, • Long term data record on flash
editable RS-485, Ethernet and GPRS • On-board Input&output extension
• 3 level configuration password • Free configuration program
• 128x64 graphical LCD display • Allows SMS controls MEASUREMENTS
• Downloadable languages • Ready for central monitoring
• Waveform display of V & I ethernet & GPRS • Mains & genset PN/PP voltages
• Harmonic analysis of V & I • Mobile genset support • Mains & genset frequency
• Synchroscope & check synch • Automatic GSM geo-location • Mains & genset phase currents
• 12 configurable digital inputs • GPS connectivity (USB&RS232) • Mains & genset neutral currents
• Inputs expandable to 44 • Dynamic DNS support • Mains & genset, phase & total,
• 8 configurable digital outputs • Easy USB firmware upgrade kW, kVA, kVAr, pf
• Outputs expandable to 40 • IP65 rating with standard gasket • Engine speed
• 7 configurable analog inputs • Battery voltage
COMMUNICATIONS

USB
ho

TECHNICAL SPECIFICATIONS
Alternator voltage: 0 to 300 V-AC (Ph-N) Data Link Port: Fully Isolated CANBUS
Alternator frequency: 0-600 Hz. Operating temperature: -20°C to 70°C (-4 to +158 °F)
Mains (Busbar) voltage: 0 to 300 V-AC (Ph-N) Storage temperature: -40°C to 80°C (-40 to +176°F)
Mains (Busbar) frequency: 0-600 Hz. Maximum humidity: 95% non-condensing.
Topology: 1-2-3 phases, with or without neutral IP Protection: IP65 from front panel, IP30 from the
DC Supply Range: 8.0 to 36.0 V-DC. rear.
V-A-cos Accuracy: 0.5% + 1 digit Dimensions: 243 x 183 x 47mm (WxHxD)
kW-kVA-kVAr Accuracy: 1.0% + 1 digit Panel Cut-out Dimensions: 216 x 156 mm minimum.
Current consumption: 500 mA-DC max. Weight: 700 g /1.55lb (approx.)
Current Inputs: from current transformers. ../5A. Case Material: High Temperature, non-flammable
Digital inputs: input voltage 0 to 36 V-DC. ABS/PC
Analog input range: 0-5000 ohms. Installation: Flat surface mounting on a Type 1 enclosure.
DigitalOutputs: Protected mosfet semiconductor Rear retaining plastic brackets.
outputs, rated 1Amp@28V-DC
Cranking dropouts: survives 0V for 100ms. CONFORMITY
Magnetic pickup voltage: 0.5 to 50Vpk.
Magnetic pickup frequency: 0 to 20000 Hz. EU Directives Conformity
GOV Control Output: 0-10V-DC • 2006/95/EC (low voltage)
AVR Control Output: ±5V-DC, fully isolated • 2004/108/EC (electro-magnetic compatibility)
Charge Alternator Excitation: 2W. Norms of reference:
Display Screen: • EN 61010 (safety requirements)
B/W versions: 2.9”, 128x64 pixels • EN 61326 (EMC requirements)
TFT versions: 4.3”, 480x272 pixels UL & CSA Compatibility:
Ethernet Port: 10/100 Mbits • UL 6200, Controls for Stationary Engine Driven
USB Device: USB 2.0 Full speed Assemblies (File# - 20140725-E314374)
USB Host: USB 2.0 Full speed • CAN/CSA C22.2 No. 14-13 – Industrial Control
RS-485 Port: selectable baud rate Equipment
RS-232 Port: selectable baud rate
WAVEFORM DISPLAY & MULTI GENSET
HARMONIC ANALYSIS SYNCHRONIZATION
Up to 48 gensets may be paralleled on the same
busbar. Smart load management is standard feature.

TO LOAD

Datalink
Bus To mains
controllers
EMBEDDED WEB SERVER

MAINS SYNCHRONIZATION
Up to 16 mains controller per system are supported .
Mains controllers provide the REMOTE START signal
and control synchronization with mains of the complete
genset system.

RAINBOW PLUS PROGRAM

REMOTE LOAD
START DATALINK
SIGNAL BUS

TO GENSET
GENSET CONTROLLERS
BUSBAR
RAINBOW SCADA PROGRAM
SINGLE GENSET PARALLEL
WITH MAINS
The controller supports synchronization and parallel
operation with mains. Supported features include soft
transfer, peak lopping, peak shaving and power export.

GENSET MAINS
LOAD
TYPICAL CONNECTIONS

REV-4