RISK ASSESSMENT
&
METHOD STATEMENT
EPC004 – HI010
RISK ASSESSMENT
ASSESSOR LEE SKINNER POSITION FITTER DOCUMENT EPC004 – HI010 DATE 25th August, 2011
NUMBER
RISK
ITEM DESCRIPTION NUMBERS
1 ISOLATION OF BLUE SILO AIR FILTERS
A). REMOVE TWO ISOLATION LOCKS AND KEYS FROM FITTERS KEY SAFE. TURN SILO MAIN POWER ISOLATOR OFF (LOCATED ON REAR
SUPPORT LEG OF THE GREEN SILO) AND LOCK WITH ISOLATION LOCK. RETAIN KEY ON YOUR PERSON UNTIL READY TO DE-ISOLATE
PLANT
B). TURN OFF BLUE SILO CONTROL PANEL ISOLATOR AND LOCK OFF. RETAIN KEY ON YOUR PERSON UNTIL READY TO DE-ISOLATE
PLANT
C). CLOSE AIR SUPPLY VALVE TO THE BLUE SILO. THIS IS THE BLACK TAP AT THE BOTTOM OF THE BLUE SILO MARKED ‘TAP’
A). OBSERVING THE PROTOCOLS LAID DOWN UNDER THE REQUIREMENTS FOR WORKING AT HEIGHT ON CEMENT SILOS, CLIMB THE
ACCESS LADDER TO THE FILTER PLATFORM. REMEMBER; NO LONE WORKING ALLOWED
B). UNDO THE TWO CATCHES BOLTS HOLDING THE FILTER COVER IN PLACE. LIFT FILTER COVER OPEN. DUST MASK AND SUITABLE EYE
PROTECTION SHOULD NOW BE WORN UNTIL THE END OF THE INSPECTION
C). REMOVE FILTERS INDIVIDUALLY FOR INSPECTION. REPLACE AS NECESSARY. REFIT FILTERS
D). REFIT FILTER COVER, ENSURING THE RETAINING CATCHES ARE SECURELY FASTENED.
E). REMOVE ALL EQUIPMENT AND DEBRIS FROM THE FILTER PLATFORM AS PRESCRIBED IN THE REQUIREMENTS FOR WORKING AT
HEIGHT ON CEMENT SILOS DOCUMENT.
3 DE-ISOLATION AND TEST RUN
B). DE-ISOLATE AND TURN ON SILO CONTROL PANEL. REMOVE ISOLATION LOCK FROM SILO POWER ISOLATOR AND TURN ON.
C). TURN ON FILTER SYSTEM AT CONTROL PANEL. ALLOW 45 MINUTES RUNNING TIME FOR THE FILTER SYSTEM AND THEN TURN OFF AT
THE CONTROL PANEL. REPLACE ALL LOCKS AND KEYS TO THE FITTERS OFFICE KEY SAFE.
DATE ……………………………………….
I HAVE READ THE ABOVE DOCUMENT AND UNDERSTAND THE WORK TO BE CARRIED OUT WITHIN THE GUIDELINES AND METHOD STATEMENT