Sie sind auf Seite 1von 43

PT PANCA AMARA UTAMA

1900 MTPD AMMONIA PROJECT


CENTRAL SULAWESI, INDONESIA

PRELIMINARY DATASHEETS FOR


ANALYSERS

F283-IC-DAS-II0-0001

Revision: 0 P00 1 2

Prepared by: NSB MM

Checked by: YL BBK

Approved by: RT RT

Revision Date: 27-Apr-13 29-Jun-13


ISSUED FOR RE-ISSUED FOR
Issue Purpose:
DESIGN DESIGN

THIS DOCUMENT CONTAINS INFORMATION WHICH IS PROPRIETARY TO KELLOGG BROWN & ROOT INTERNATIONAL, INC. (KBR).
THIS INFORMATION IS TO BE HELD IN CONFIDENCE. NO DISCLOSURE, REPRODUCTION OR OTHER USE OF THIS DOCUMENT IS
TO BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF KELLOGG BROWN & ROOT INTERNATIONAL, INC. (KBR).

THIS DOCUMENT CONTAINS INFORMATION THAT IS SUBJECTED TO U.S. CONTROL REGULATIONS, INCLUDING RESTRICTIONS
ON THE EXPORT, SALES OR TRANSFER OF U.S. ORGIN ITEMS (GOODS, TECHNOLOGY OR SOFTWARE) TO SANCTIONED OR
EMBARGOED COUNTRIES, ENTITIES EXCEPT AS AUTHORIZED UNDER U.S. EXPORT CONTROL REQUIREMENTS.
PAGE
TAG NUMBER P&ID SERVICE DESCRIPTION INSTRUMENT TYPE REMARKS REV
NO.

SAMPLE POINTS: AE-


AT-1000 SEE PAGE 3, 4 SEE PAGE 3, 4 MASS SPECTROMETER 1036/1001/1030/1011/1031/ 2 P00
1002/1013/1022/1029

AT-1004 62-D103 FEED GAS TO 101-B FROM 108-DB/C SULPHUR 6 P00

AT-1484 62-D104 101-BL REFORMER FURNACE STACK CEMS ANALYZER 9 P00

AT-1033A/B 62-D105 101-B FLUE GAS O2/COMBUSTIBLES 11 P00

AT-1034A/B 62-D105 101-B FLUE GAS O2/COMBUSTIBLES 13 P00

AT-1010A/B 62-D106 101-B RADIANT SECTION FLUE GAS O2/COMBUSTIBLES 15 P00

AT-1021A/B 62-D106 101-B RADIANT SECTION FLUE GAS O2/COMBUSTIBLES 17 P00

AT-1023 62-D110 142-D2 PROCESS GAS OUTLET INFRA RED ANALYZER 19 P00

AT-1003 62-D111 SYNGAS TO 115-C CO/CO2 ANALYZER 21 P00

AT-1014 62-D112 109-DA/DB S.G. OUTLET MOISTURE 23 P00


109-DA/DB MOLECULAR SIEVE DRYER
AT-1020 62-D112 CO2 ANALYZER 25 P00
OUTLET
AT-1017 62-D120 174-C PROCESS COND. OUTLET CONDUCTIVITY 27 P00

AT-1006 64-D101 141-D STEAM DRUM BLOWDOWN PH ANALYZER 29 P00

AT-1050 64-D101 141-D STEAM DRUM BLOWDOWN CONDUCTIVITY 31 P00

AT-1051 64-D101 STEAM SUPPLY FROM 141-D CONDUCTIVITY 33 P00

AT-1019 64-D105A 112-J/A CONDENSATE PUMP OUTLET CONDUCTIVITY 35 P00

AT-4019 64-D105C 118-J/JA CONDENSATE PUMP OUTLET CONDUCTIVITY 37 P00

AT-1007 64-D106 101-U DEAERATOR BFW OUTLET PH ANALYZER 39 P00

AT-1015 64-D106 101-U DEAERATOR BFW MAKEUP WATER CONDUCTIVITY 41 P00

ANALYZERS
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 1 of 42
1 Tag Number AT-1000
2 Service See Page No. 3, 4
GENERAL
3 Application Equipment No. MASS SPECTROMETER
4 Line No. P & ID No. See Page No. 3, 4 See Page No. 3, 4
5 Fluid 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature Deg C 29 See Page No. 3, 4
9 Pressure kg/cm2 (g) 30
See Page No. 3, 4
10 Density kg/m³ 31
11 Viscosity cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration (All wet basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37
17 Line Length By Supplier 38
Sample
18 Tap Connection By Supplier 39
17 Piping Size By Supplier 40
19 Design Pressure BY DEC 41
21 Design Temperature BY DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1000 51 Mounting Signal By Supplier Serial Data Hwy
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Enclosure Area Class IP 65 Min. BY DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy By Supplier
50 54
55 Tag Number See Page No. 3, 4 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule See Page No. 3, 4 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range See Page No. 3, 4
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure BY DEC kg/cm2 (g) 67 Area Class. BY DEC
61 Max Design Temperature BY DEC Deg C 68 Accuracy in % N/A
69 Tag Number See Page No. 3, 4 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. BY DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level BY DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes BY DEC
76 Scale Type 89 Purge Media Instrument air
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
By DEC
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number BY DEC
PURCHASE 96 Manufacturer BY DEC 99 Remarks See Notes on Page 5
97 Model

MASS SPECTROMETER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 2 of 42
Sample Point ID
Stream Component
Service
Stream Meas.
P&ID Number Stream Process Conditions Component Composition Unit Notes
No. DCS Tag Number Range
Line Number

AI-1036A CH4 91.00 Mol% 0-150


AE-1036 Pressure kg/cm2 g 49.17 AI-1036B C2H6 4.08 Mol% 0-10
174-D KO DRUM OVHD Temperature Deg C 35.00 AI-1036C C3H8 1.98 Mol% 0-5
62-D102 Viscosity cP 0.01 AI-1036D N2 1.11 Mol% 0-5
1
NG1500-12" (06CB1S01) Density kg/m3 37.90 AI-1036E CO2 0.01 Mol% 0-0.1
SCH XS AI-1036F C4+ 1.80 Mol% 0-5
H2O 0.02 Mol% 0-0.1

H2 25.06 Mol% 0-30


AE-1001 Pressure kg/cm2 g 39.95 CO 1.69 Mol% 0-5
107-D TRANSFER LINE Temperature Deg C 703.20 AI-1001A CH4 16.31 Mol% 0-40
2 62-D106 Viscosity cP 0.03 H2O 50.88 Mol% 0-100
107-D Density kg/m3 7.56 CO2 5.64 Mol% 0-10
Note: Need SOV (XY-1208)

AI-1030A CH4 1.13 Mol% 0-5


AE-1030 Pressure kg/cm2 g 38.35 AI-1030B H2 32.89 Mol% 0-50
PROCESS GAS TO HTS Temperature Deg C 371.10 AI-1030C N2 20.15 Mol% 0-50
CONVERTER 104-D1 Viscosity cP 0.03 AI-1030D Ar 0.26 Mol% 0-0.5
3
62-D107A Density kg/m3 12.21 AI-1030E CO 7.77 Mol% 0-20
PG1002-30" (06CJ1S01) AI-1030F CO2 5.48 Mol% 0-10
SCH 80 H2O 32.32 Mol% 0-50
Note: Need SOV (XY-1209)
AI-1011A CH4 1.13 Mol% 0-5
AE-1011 Pressure kg/cm2 g 37.70 AI-1011B H2 38.40 Mol% 0-50
H.T.S EFFLUENT Temperature Deg C 395.00 AI-1011C N2 20.15 Mol% 0-50
62-D108 Viscosity cP 0.03 AI-1011D Ar 0.26 Mol% 0-0.5
4
PG1010-36" (06CJ1S01) Density kg/m3 11.55 AI-1011E CO 2.26 Mol% 0-5
SCH 80 AI-1011F CO2 10.98 Mol% 0-20
H2O 26.81 Mol% 0-50
Note: Need SOV (XY-1311)
AI-1031A CH4 1.13 Mol% 0-5
AE-1031 Pressure kg/cm2 g 36.98 AI-1031B H2 40.46 Mol% 0-50
L.T.S EFFLUENT Temperature Deg C 225.47 AI-1031C N2 20.15 Mol% 0-50
62-D108A Viscosity cP 0.02 AI-1031D Ar 0.26 Mol% 0-0.5
5
PG1012-30" (06CB2S02) Density kg/m3 15.29 AI-1031E CO 0.20 Mol% 0-0.5
SCH 80 AI-1031F CO2 13.05 Mol% 0-20
H2O 24.75 Mol% 0-50
Note: Need SOV (XY-1331)

AE-1002 Pressure kg/cm2 g 34.50 AI-1002A CH4 2.11 Mol% 0-5


144-D SYNGAS TO 109-DA/B Temperature Deg C 35.53 AI-1002B H2 64.83 Mol% 0-100
6 62-D111A Viscosity cP 0.01 AI-1002C N2 32.21 Mol% 0-50
SG1004-20" (03CB1S01) Density kg/m3 16.34 AI-1002D Ar 0.62 Mol% 0-1
SCH XS H2O 0.03 Mol% 0-0.1

AI-1013A CH4 0 Mol% 0-1


AE-1013 Pressure kg/cm2 g 31.04 AI-1013B H2 74.75 Mol% 0-100
PURIFIER SYNGAS Temperature Deg C 1.78 AI-1013C N2 24.93 Mol% 0-50
62-D112A Viscosity cP 0.01 AI-1013D Ar 0.31 Mol% 0-1
7
SG1411-20" (03CB1S01) Density kg/m3 11.67
SCH XS

MASS SPECTROMETER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 3 of 42
Sample Point ID
Stream Component
Service
Stream Meas.
P&ID Number Stream Process Conditions Component Composition Unit Notes
No. DCS Tag Number Range
Line Number

AI-1022A CH4 0.03 Mol% 0-0.1


AE-1022 Pressure kg/cm2 g 153.27 AI-1022B H2 57.09 Mol% 0-100
121-C S.G. EFFLUENT Temperature Deg C 83.88 AI-1022C N2 19.09 Mol% 0-50
OUTLET Viscosity cP 0.02 AI-1022D Ar 4.08 Mol% 0-10
62-D114 Density kg/m3 56.37 AI-1022E NH3 19.70 Mol% 0-50
8
SG1005-24" (15CB1S01)
SCH 120

AI-1029A CH4 0.03 Mol% 0-0.1


AE-1029 Pressure kg/cm2 g 157.92 AI-1029B H2 70.99 Mol% 0-100
NH3 CONVERTER FEED Temperature Deg C 66.88 AI-1029C N2 23.72 Mol% 0-50
62-D114 Viscosity cP 0.02 AI-1029D Ar 3.47 Mol% 0-5
9
SG1010-24" (15CB1S01) Density kg/m3 49.69 AI-1029E NH3 1.79 Mol% 0-5
SCH 120

AI-1008A CH4 91.00 Mol% 0-100


AE-1008 PRESSURE kg/cm2 g 50.42 AI-1008B C2H6 4.08 Mol% 0-10
NATURAL GAS FEED Temperature Deg C 34.69 AI-1008C C3H8 1.98 Mol% 0-5
10 62-D102B Viscosity cP 0.01 AI-1008D N2 1.11 Mol% 0-5
NG1004-10" (O6CB1S01) Density kg/m3 37.9 AI-1008E CO2 0.01 Mol% 0-0.1
SCH 80 AI-1008F C4+ 1.80 Mol% 0-5
AI-1008G H2 0 Mol% 0-1
H2O 0.02 Mol% 0-0.1

MASS SPECTROMETER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 4 of 42
Tag Number: AT-1000

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Transport time shall be less than 30 seconds. Supplier shall provide transport time calculations for review.

3. Supplier to advise cycle time.

4. Sample probe length shall be determined during Detailed Engineering. Sample probe shall be
fixed (non-retractable) type. Probe vibration calculations shall be provided for review.
Need probes where noted on data page.

5. Sample system enclosure rating to be IP 65, minimum.

6. Supplier to specify all gas bottle requirements, including carrier and calibration gases, wherever required.

7. Supplier shall advise if quadrapole or magnetic sector measurement technology is used and/or recommended.

8. Supplier shall recommend any equipment or accessories required for best operation and reliability.

9. Supplier shall configure analyzer and sampling system for manually initiated automatic calibration. Sample system
shall deliver a representative vaporized sample with no condensation.

10. This Mass Spectrometer is to be installed in the Analyzer Shelter.

11. Number of streams measured: there are 10 streams.

12. Mass Spectrometer AT-1000 common for 10 streams.

13. Remote sample conditioning shall include sample isolation valves to shutdown samples on process shutdown.
SOV: 110 VAC, 316SS.

14. Sample system is to include facilities for removing water from the samples for a "dry basis" measurement.

15. Sample system design shall prevent backflow and cross-contamination. Spent samples shall be connected to
the shelter vent header.

MASS SPECTROMETER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 5 of 42
1 Tag Number AT-1004
2 Service FEED GAS TO FEED PREHEAT COIL / FEED GAS TO 101-B FROM 108-DB/DC
GENERAL
3 Application Equipment No. SULPHUR ANALYZER N/A
4 Line No. P & ID No. (NG1004-10"/ NG1007-12") (06CB1S01) 62-D102B / 62-D103
5 Fluid FEED GAS 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 42,386 Nm3/hr 28 Component Unit Nor Max Calib.Range
8 Temperature 360 Deg C 29 Refer Sheet 6A
9 Pressure 48.04 Kg/sqcm(g) 30
10 Density 15.89 Kg/cum 31
11 Viscosity 0.020 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials BY SUPPLIER 37
17 Line Length BY SUPPLIER 38 Refer Sheet 6A
Sample
18 Tap Connection BY SUPPLIER 39
17 Piping Size BY SUPPLIER 40

19 Design Pressure By DEC 41


21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type BY SUPPLIER 43
Calibration
23 Concentration BY SUPPLIER 44 Required Reagents
Sample
24 Flow Rate BY SUPPLIER 45
25 46
47 Tag Number AT-1004 51 Mounting Signal RACK 4-20mA + HART
TRANS- 48 Supply Volts Amps 110V, 50 Hz BY SUPPLIER 52 Enclosure Area Class IP 65, MIN NOTE 6
MITTER 49 Scale Indicating Type BY SUPPLIER BY SUPPLIER 53 Accuracy +/- 1% OF FULL SCALE
50 54
55 Tag Number AE-1004 / AE-1008 62 Model No. BY SUPPLIER
56 Supply Volts Amps N/A N/A 63 Size Type | Rating BY SUPPLIER
SENSOR/ 57 Line Size Schedule 10" / 12" STD 64 Process Connection BY DEC
ELEMENT 58 Oper. Temp Max | Min BY DEC BY DEC 65 Measuring Range 0 - 1 ppmv / 0 - 50 ppmv
59 Material BY DEC 66 Enclosure IP 65, MIN
60 Max Design Pressure BY DEC Kg/sqcm(g) 67 Area Class. NOTE 6
61 Max Design Temperature BY DEC ºC 68 Accuracy in % BY SUPPLIER
69 Tag Number AI-1004 82 Enclosure IP 65, MIN
70 Supply V | A | Hz 83 Area Class. BY DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level BY DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes BY DEC
76 Scale Type 89 Purge Media BY DEC
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 SUPPLIER 98 Purchase Order Number BY DEC
PURCHASE 96 Manufacturer BY DETAIL ENGG 99 Remarks SEE NOTES ON PAGE 8.
97 Model

SULPHUR ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 6 of 42
Sample Point ID
Stream Component
Service
Stream Meas.
P&ID Number Stream Process Conditions Component Composition Unit Notes
No. DCS Tag Number Range
Line Number

H2 1.954 Mol%
1/2 CH4 88.498 Mol%
AE-1004 Pressure kg/cm2(g) 47.014 C2H6 3.97 Mol%
FEED GAS TO 101-B Temperature °C 360 C3H8 1.93 Mol%
62-D103 Viscosity cP 0.02 N2 1.733 Mol% Not wet
NG1007-12" (06CB1S01) Density Kg/m3 15.89 CO2 0.01 Mol% 0-1 basis
AI-1004
SCH 80 I-C4 0.4181 Mol% ppmv
N-C4 0.5737 Mol%
I-C5 0.282 Mol%
N-C5 0.1945 Mol%
C6+ 0.282 Mol%
Total S <0.1 PPMV
H2 0 Mol%
2/2 CH4 91.02 Mol%
AE-1008 Pressure kg/cm2(g) 48.424 C2H6 4.08 Mol%
FEED GAS TO FEED PREHEAT COIL Temperature °C 34.69 C3H8 1.98 Mol%
62-D102B Viscosity cP 0.0123 N2 1.11 Mol% Not wet
NG1004-10" (06CB1S01) Density Kg/m3 37.9 CO2 0.01 Mol% 0-50 basis
-
SCH 80 I-C4 0.43 Mol% ppmv
N-C4 0.59 Mol%
I-C5 0.29 Mol%
N-C5 0.2 Mol%
C6+ 0.29 Mol%
Total S 17.5 PPMV

SULPHUR ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 7 of 42
Tag Number: AT-1004

NOTES:
1 Supplier shall be responsible for selection of contact material based on the process fluid properties.

2 Sample system enclosure rating to be IP 65, minimum. Analyzer will share a common sample conditioning system

3 Supplier shall recommend any equipment or accessories required for best operation and reliability.

4 Sample tubing, cylinder gases and regulators will be determined during detail engineering.

5 Supplier shall configure analyzer for manually initiated automatic calibration.

6 Area classification shall be considered as Class 1, Div II, Group D. DEC to confirm the same based on final area
clasification.

SULPHUR ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 8 of 42
1 Tag Number AT-1484
2 Service 101-BL REFORMER FURNACE STACK
GENERAL
3 Application Equipment No. CEMS ANALYZER 101-BL
4 Line No. P & ID No. N/A 62-D104
5 Fluid 26 Components to be Analyzed
6 Min Nor Max UOM 27 Dry Concentration
7 Flow BY VENDOR BY VENDOR BY VENDOR kg/h 28 Component Unit Nor Max Calib. Range
8 Temperature 99.30 111.0 123.6 Deg C 29 O2 mole% 1.74 0-5
9 Pressure -5.0 -2.0 4.0 mmH2O 30 NOx mg/Nm3 300 0-500
10 Density kg/m³ 31 CO ppm BY DEC BY DEC
11 Viscosity cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37
17 Line Length By Supplier 38 N2 71.86. mol %
Sample
18 Tap Connection By Supplier 39 H2O 19.45 mol %
17 Piping Size By Supplier 40 CO2 7.29 mol %
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
Calibration
23 Concentration By Supplier 44 Required Reagents
Sample
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1484 51 Mounting Signal Rack By Supplier
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 2% of Full Scale
50 54
55 Tag Number AE-1484 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule N/A By DEC 64 Process Connection By DEC
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range By DEC
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % By Supplier
69 Tag Number AI-1484A/B/C 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media By Supplier
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
By DEC
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 10
97 Model

CEMS ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 9 of 42
Tag Number: AT-1484

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. CEMS analyzer, measuring NOx (AI-1484B), O2 (AI-1484A), and CO (AI-1484C) are extractive type with a
suitable probe on the stack and will be rack mounted inside the analyzer shelter.
Analyzer should be located in the cabinet near the base of the stack.

3. Sample system enclosure rating to be IP 65, minimum. Analyzer will share a common sample conditioning system

4. Supplier shall recommend any equipment or accessories required for best operation and reliability.

5. Sample tubing, cylinder gases and regulators will be determined during detail engineering.

6. Supplier shall configure analyzer for manually initiated automatic calibration.

CEMS ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 10 of 42
1 Tag Number AT-1033A/B
2 Service 101-B FLUE GAS
GENERAL
3 Application Equipment No. O2/ COMBUSTIBLES 101-B DUCT
4 Line No. P & ID No. N/A 62-D105
5 Fluid FLUE GAS 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 294,290 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 863 Deg C 29 O2 mol % 1.40 0-10
9 Pressure -5 to -10 mmH2O 30 CO mol % 0.00 0-1
10 Density kg/m³ 31
11 Viscosity cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37
17 Line Length By Supplier 38 N2 71.86. mol %
Sample
18 Tap Connection By Supplier 39 H2O 19.45 mol %
17 Piping Size By Supplier 40 CO2 7.29 mol %
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1033A/B 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-1033 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule N/A By DEC 64 Process Connection By DEC
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1033A/B 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media Instrument air
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
By DEC
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 12
97 Model

O2 / COMBUSTIBLES ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 11 of 42
Tag Number: AT-1033A/B

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Sample component information is wet basis

3. Supplier to specify all gas bottle requirements (zero, span, etc).

4. Supplier shall recommend any equipment or accessories required for best operation and reliability.

5. Seller shall configure analyzer for manually initiated automatic calibration.

6. Control Unit is to be installed in Analyzer Shelter.

7. Number of streams measured: 1.

8. Sensor shall be suitable for mounting on a horizontal flanged connection.

O2 / COMBUSTIBLES ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 12 of 42
1 Tag Number AT-1034A/B
2 Service 101-B FLUE GAS
GENERAL
3 Application Equipment No. O2/ COMBUSTIBLES 101-B DUCT
4 Line No. P & ID No. N/A 62-D105
5 Fluid FLUE GAS 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 294,290 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 863 Deg C 29 O2 mol % 1.40 0-10
9 Pressure -5 to -10 mmH2O 30 CO mol % 0.00 0-1
10 Density kg/m³ 31
11 Viscosity cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37
17 Line Length By Supplier 38 N2 71.86. mol %
Sample
18 Tap Connection By Supplier 39 H2O 19.45 mol %
17 Piping Size By Supplier 40 CO2 7.29 mol %
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1034A/B 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-1034 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule N/A By DEC 64 Process Connection By DEC
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1034A/B 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media Instrument air
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
By DEC
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 14
97 Model

O2 / COMBUSTIBLES ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 13 of 42
Tag Number: AT-1034A/B

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Sample component information is wet basis

3. Supplier to specify all gas bottle requirements (zero, span, etc).

4. Supplier shall recommend any equipment or accessories required for best operation and reliability.

5. Seller shall configure analyzer for manually initiated automatic calibration.

6. Control Unit is to be installed in Analyzer Shelter.

7. Number of streams measured: 1.

8. Sensor shall be suitable for mounting on a horizontal flanged connection.

O2 / COMBUSTIBLES ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 14 of 42
1 Tag Number AT-1010A/B
2 Service 101-B RADIANT SECTION FLUE GAS
GENERAL
3 Application Equipment No. O2/ COMBUSTIBLES 101-B DUCT
4 Line No. P & ID No. N/A 62-D106
5 Fluid FLUE GAS 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 232,110 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 976 ºC 29 O2 mol % 1.40 0-10
9 Pressure -5 to -10 mmH2O 30 CO mol % 0.00 0-1
10 Density kg/m³ 31
11 Viscosity cP 32
12 Conductivity us/cm 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37
17 Line Length By Supplier 38 N2 71.86. mol %
Sample
18 Tap Connection By Supplier 39 H2O 19.45 mol %
17 Piping Size By Supplier 40 CO2 7.29 mol %
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1010A/B 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-1010 62 Model No. By Supplier
56 Supply Volts Amps NA NA 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule N/A By DEC 64 Process Connection By DEC
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC ºC 68 Accuracy in % N/A
69 Tag Number AI-1010A/B 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media Instrument air
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 16
97 Model

O2 / COMBUSTIBLES ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 15 of 42
Tag Number: AT-1010A/B

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Sample component information is wet basis

3. Supplier to specify all gas bottle requirements (zero, span, etc).

4. Supplier shall recommend any equipment or accessories required for best operation and reliability.

5. Seller shall configure analyzer for manually initiated automatic calibration.

6. Control Unit is to be installed in Analyzer Shelter.

7. Number of streams measured: 1.

8. Sensor shall be suitable for mounting on a horizontal flanged connection.

9. Horizontal duct with vertical (probe pointed downwards) flanged connection.

O2 / COMBUSTIBLES ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 16 of 42
1 Tag Number AT-1021A/B
2 Service 101-B RADIANT SECTION FLUE GAS
GENERAL
3 Application Equipment No. O2/ COMBUSTIBLES 101-B DUCT
4 Line No. P & ID No. N/A 62-D106
5 Fluid FLUE GAS 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 232,110 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 976 ºC 29 O2 mol % 1.40 0-10
9 Pressure 0.00 mmH2O 30 CO mol % 0.00 0-1
10 Density -5 to -10 kg/m³ 31
11 Viscosity cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37
17 Line Length By Supplier 38 N2 71.86 mol %
Sample
18 Tap Connection By Supplier 39 H2O 19.45 mol %
17 Piping Size By Supplier 40 CO2 7.29 mol %
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1021A/B 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-1021 62 Model No. By Supplier
56 Supply Volts Amps NA NA 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule N/A By DEC 64 Process Connection By DEC
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC ºC 68 Accuracy in % N/A
69 Tag Number AI-1021A/B 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media Instrument air
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 18
97 Model

O2 / COMBUSTIBLES ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 17 of 42
Tag Number: AT-1021A/B

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Sample component information is wet basis

3. Supplier to specify all gas bottle requirements (zero, span, etc).

4. Supplier shall recommend any equipment or accessories required for best operation and reliability.

5. Seller shall configure analyzer for manually initiated automatic calibration.

6. Control Unit is to be installed in Analyzer Shelter.

7. Number of streams measured: 1.

8. Sensor shall be suitable for mounting on a horizontal flanged connection with verical flanged connection (probe
pointed downwards).

O2 / COMBUSTIBLES ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 18 of 42
1 Tag Number AT-1023
2 Service 142-D2 CO2 ABSORBER OVERHEAD KOD OUTLET
GENERAL
3 Application Equipment No. INFRA RED ANALYZER N/A
4 Line No. P & ID No. PG1017-20" (03CB2S01) 62-D110
5 Fluid PROCESS GAS 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 123,392 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 50 Deg C 29 CO2 ppmv 498.73 0-1000 ppmv
9 Pressure 35.82 kg/cm2 (g) 30
10 Density 14.51 kg/m³ 31
11 Viscosity 0.0162 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 H2 64.80 mole%
17 Line Length By Supplier 38 N2 32.35 mole%
Sample
18 Tap Connection By Supplier 39 CH4 1.81 mole%
17 Piping Size By Supplier 40 Ar 0.42 mole%
19 Design Pressure By DEC 41 CO 0.32 mole%
21 Design Temperature By DEC 42 H2O 0.25 mole%
22 Type By Supplier 43 By DEC Qty. Consumption
23 Concentration By Supplier 44 By DEC
24 Flow Rate By Supplier 45 Required Reagents
25 46
47 Tag Number AT-1023 51
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Mounting Signal By Supplier 4~20 mA+HART
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Enclosure Area Class IP 65 Min. By DEC
50 54 Accuracy By Supplier
55 Tag Number AE-1023 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 20" XS 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 0-1000 ppmv
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in %
69 Tag Number AI-1023 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media Instrument air
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
By DEC
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Vendor 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 20
97 Model

INFRARED ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 19 of 42
Tag Number: AT-1023

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Transport time shall be less than 90 seconds. Supplier shall provide transport time calculations for review.

3. Sample probe shall be fixed (non-retractable) type. Probe variation calculations shall be provided for review.

4. Sample system enclosure rating to be IP 65, minimum.

5. Supplier to specify all gas bottle requirements.

6. Supplier shall recommend any equipment or accessories required for best operation and reliability.

7. Seller shall configure analyzer and sampling system for manually initiated automatic calibration.

8. This analyzer is to be installed in the Analyzer shelter.

9. Number of streams measured: 1

10. Sample system to include facilities for removing water from the sample for a "dry basis" measurement.
Sample is saturated with water vapor at sampling conditions.

11. Sample system design shall prevent backflow. Spent samples shall be connected to the shelter vent header.

INFRARED ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 20 of 42
1 Tag Number AT-1003
2 Service SYNGAS TO 115-C
GENERAL
3 Application Equipment No. CO/CO2 ANALYZER N/A
4 Line No. P & ID No. SG1002-20" (03CB1S01) 62-D111
5 Fluid SYN GAS 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 123,397 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 79.7 Deg C 29 CO ppmv NOTE 10 0-10 ppmv
9 Pressure 35.00 kg/cm2 (g) 30 CO2 ppmv NOTE 10 0-10 ppmv
10 Density 13.10 kg/m³ 31
11 Viscosity 0.017 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 H2 64.12 mole%
17 Line Length By Supplier 38 N2 32.59 mole%
Sample
18 Tap Connection By Supplier 39 CH4 2.19 mole%
17 Piping Size By Supplier 40 Ar 0.42 mole%
19 Design Pressure By DEC 41 H2O 0.68 mole%
21 Design Temperature By DEC 42
22 Type By Supplier 43 By DEC Qty. Consumption
23 Concentration By Supplier 44 By DEC
24 Flow Rate By Supplier 45 Required Reagents
25 46
47 Tag Number AT-1003 51
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Mounting Signal By Supplier 4-20 mA+HART
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Enclosure Area Class IP 65 Min. By DEC
50 54 Accuracy By Supplier
55 Tag Number AE-1003 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 20" XS 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1003A/B 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media Instrument air
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
By DEC
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Vendor 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 22
97 Model

CO/CO2 ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 21 of 42
Tag Number: AT-1003

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Sample component information is wet basis.

3. Supplier to specify all gas bottle requirements.

4. Supplier shall recommend any equipment or accessories required for best operation and reliability.

5. Seller shall configure analyzer and sampling system for manually initiated automatic calibration.

6. This analyzer is to be installed in the Analyzer shelter. Control Unit is to be installed in Analyzer Shelter.

7. Number of streams measured: 1

8. Sample system to include facilities for removing water from the sample for a "dry basis" measurement.

9. Sample system design shall prevent backflow. Spent samples shall be connected to the shelter vent header.

10. Combined CO and CO2 content in Methanator 106-D outlet stream shall be less than 10 ppmv.

CO/CO2 ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 22 of 42
1 Tag Number AT-1014
2 Service 109-DA/DB MOLECULAR SIEVE DRYER OUTLET
GENERAL
3 Application Equipment No. MOISTURE ANALYZER N/A
4 Line No. P & ID No. SG1009-20" (03CB1S01) 62-D112
5 Fluid SYN GAS 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 127,104 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 4 Deg C 29 H2O ppmv <1 0-10 ppmv
9 Pressure 34.1 kg/cm2 (g) 30
10 Density 1.47 kg/m³ 31
11 Viscosity 0.015 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 H2 62.84 mole%
17 Line Length By Supplier 38 N2 32.42 mole%
Sample
18 Tap Connection By Supplier 39 CH4 2.11 mole%
17 Piping Size By Supplier 40 AR 0.62 mole%
19 Design Pressure By DEC 41 NH3, H2O, CO2 <1 ppmv
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1014 51 Mounting Signal By Supplier 4~20 mA+HART
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy By Supplier
50 54
55 Tag Number AE-1014 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 20" XS 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 0-10 ppmv
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % By Supplier
69 Tag Number AI-1014 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media Instrument air
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 24
97 Model

MOISTURE ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 23 of 42
Tag Number: AT-1014

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Transport time shall be less than 90 seconds. Supplier shall provide transport time calculation for review.

3. Sample system enclosure rating to be IP 65, minimum.

4. Supplier to specify all calibration gases.

5. Supplier shall recommend any equipment or accessories required for best operation and reliability.

6. Analyzer Sensor is to be installed inline with intergral Transmitter.

7. Number of streams measured: 1.

MOISTURE ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 24 of 42
1 Tag Number AT-1020
2 Service 109-DA/DB MOLECULAR SIEVE DRYER OUTLET
GENERAL
3 Application Equipment No. CO2 ANALYZER N/A
4 Line No. P & ID No. SG1009-20" (03CB1S01) 62-D112
5 Fluid SYN GAS 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 127,104 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 4 Deg C 29 CO2 ppmv <1 0-5 ppmv
9 Pressure 34.1 kg/cm2 (g) 30
10 Density 1.47 kg/m³ 31
11 Viscosity 0.015 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 H2 62.84 mole%
17 Line Length By Supplier 38 N2 32.42 mole%
Sample
18 Tap Connection By Supplier 39 CH4 2.11 mole%
17 Piping Size By Supplier 40 Ar 0.62 mole%
19 Design Pressure By DEC 41 NH3, H2O, CO2 <1 ppmv
21 Design Temperature By DEC 42
22 Type By Supplier 43 By DEC Qty. Consumption
23 Concentration By Supplier 44 By DEC
24 Flow Rate By Supplier 45 Required Reagents
25 46
47 Tag Number AT-1020 51
TRANS- 48 Supply Volts Amps 110V 50 Hz By Supplier 52 Mounting Signal By Supplier 4-20 mA+HART
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Enclosure Area Class IP 65 Min. By DEC
50 54 Accuracy +/- 1% of Full Scale
55 Tag Number AE-1020 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 20" XS 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 0-5 ppmv
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1020 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media Instrument air
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
By DEC
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Vendor 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 26
97 Model

CO2 ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 25 of 42
Tag Number: AT-1020

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Sample component information is wet basis.

3. Sample system enclosure rating to be IP 65, minimum.

4. Supplier to specify all gas bottle requirements.

5. Supplier shall recommend any equipment or accessories required for best operation and reliability.

6. Seller shall configure analyzer and sampling system for manually initiated automatic calibration.

7. This analyzer is to be installed in the Analyzer shelter. Control Unit is to be installed in Analyzer Shelter.

8. Number of streams measured: 1

9 Sample system design shall prevent backflow. Spent samples shall be connected to the shelter vent header.

CO2 ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 26 of 42
1 Tag Number AT-1017
2 Service 174-C PROCESS COND. OUTLET
GENERAL
3 Application Equipment No. LIQ. CONDUCTIVITY ANALYZER N/A
4 Line No. P & ID No. PC1012-6" (01CB2S01) 62-D120
5 Fluid PROCESS CONDENSATE 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 77,690 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 40 Deg C 29 Conductivity µs/cm 10.00 25.0 0-50
9 Pressure 45.08 kg/cm2 (g) 30
10 Density 994.22 kg/m³ 31
11 Viscosity 0.671 cP 32
12 Conductivity us/cm 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37
17 Line Length By Supplier 38 H2O 100 100 100 %
Sample
18 Tap Connection By Supplier 39
17 Piping Size By Supplier 40
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1017 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 24V DC Loop Pwd By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-1017 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 6" STD 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 0-50 µs/cm
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1017 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media N/A
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
N/A
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 28
97 Model

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 27 of 42
Tag Number: AT-1017

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Conductivity cell shall be provided with automatic temperature compensation.

3. Sample system enclosure rating to be IP 65, minimum.

4. Supplier to specify all consummables, including reagents and calibration materials.

5. Supplier shall recommend any equipment or accessories required for best operation and reliability.

6. This analyzer is to be installed in the field.

7. Number of streams measured: 1

8. Range to be confirmed during Detail Engineering.

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 28 of 42
1 Tag Number AT-1006
2 Service 141-D STEAM DRUM BLOWDOWN
GENERAL
3 Application Equipment No. pH ANALYZER N/A
4 Line No. P & ID No. 2"-BO1004 (15CB1S02) 64-D101
5 Fluid WATER 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 2,825 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 328 Deg C 29 BFW PH 7.0 8.0 2-12
9 Pressure FV 128.50 kg/cm2 (g) 30
10 Density 646.39 kg/m³ 31
11 Viscosity 0.075 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 N/A
17 Line Length By Supplier 38
Sample
18 Tap Connection By Supplier 39
17 Piping Size By Supplier 40
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1006 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 24V DC Loop Pwd By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 0.2% of Full Scale
50 54
55 Tag Number AE-1006 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 2" 160 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 2-12 pH
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1006 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media N/A
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
N/A
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 30
97 Model

PH ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 29 of 42
Tag Number: AT-1006

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Analyzer fast loop return will be connected to open drain.

3. To be confirmed during Detail Engineering.

4. Service water is available for sample cooling.

PH ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 30 of 42
1 Tag Number AT-1050
2 Service 141-D STEAM DRUM BLOWDOWN
GENERAL
3 Application Equipment No. LIQ. CONDUCTIVITY ANALYZER N/A
4 Line No. P & ID No. BO1004-2" (15CB1S02) 64-D101
5 Fluid WATER 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 2,825 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 328 Deg C 29 Conductivity µS/cm 1.00 3.0 0-10
9 Pressure FV 128.50 kg/cm2 (g) 30
10 Density 646.39 kg/m³ 31
11 Viscosity 0.075 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 H2O 100 100 100 %
17 Line Length By Supplier 38
Sample
18 Tap Connection By Supplier 39
17 Piping Size By Supplier 40
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1050 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 24V DC Loop Pwd By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-1050 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 2" 160 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 0-10 µs/cm
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1050 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media N/A
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
N/A
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 32
97 Model

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 31 of 42
Tag Number: AT-1050

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Conductivity cell shall be provided with automatic temperature compensation.

3. Sample system enclosure rating to be IP 65, minimum.

4. Supplier to specify all consummables, including reagents and calibration materials.

5. Supplier shall recommend any equipment or accessories required for best operation and reliability.

6. This analyzer is to be installed in the field.

7. Number of streams measured: 1

8. Range to be confirmed during Detail Engineering.

9. Service water is available for sample cooling.

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 32 of 42
1 Tag Number AT-1051
2 Service STEAM SUPPLY FROM 141-D
GENERAL
3 Application Equipment No. LIQ. CONDUCTIVITY ANALYZER N/A
4 Line No. P & ID No. HS1001-18" (15CB1S02) 64-D101
5 Fluid STEAM 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 279,710 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 328 Deg C 29 Conductivity µS/cm 1.00 3.0 0-10
9 Pressure 128.5 kg/cm2 (g) 30
10 Density 74.08 kg/m³ 31
11 Viscosity 0.021 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 H2O 100 100 100 %
17 Line Length By Supplier 38
Sample
18 Tap Connection By Supplier 39
17 Piping Size By Supplier 40
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1051 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 24V DC Loop Pwd By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-1051 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 18" 160 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 0-10 µs/cm
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1051 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media N/A
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
N/A
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Vendor 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 34
97 Model

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 33 of 42
Tag Number: AT-1051

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Conductivity cell shall be provided with automatic temperature compensation.

3. Sample system enclosure rating to be IP 65, minimum.

4. Supplier to specify all consummables, including reagents and calibration materials.

5. Supplier shall recommend any equipment or accessories required for best operation and reliability.

6. This analyzer is to be installed in the field.

7. Number of streams measured: 1

8. Range to be confirmed during Detail Engineering.

9. Service water is available for sample cooling.

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 34 of 42
1 Tag Number AT-1019
2 Service 112-J/A CONDENSATE PUMP OUTLET
GENERAL
3 Application Equipment No. LIQ. CONDUCTIVITY ANALYZER N/A
4 Line No. P & ID No. SC1003-4" (01CB1S02) 64-D105A
5 Fluid STEAM CONDENSATE 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 39,444 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 49 51 Deg C 29 Conductivity µS/cm 1.00 3.0 0-10
9 Pressure 7.27 kg/cm2 (g) 30
10 Density 998.00 kg/m³ 31
11 Viscosity 0.554 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 H2O 100 100 100 %
17 Line Length By Supplier 38
Sample
18 Tap Connection By Supplier 39
17 Piping Size By Supplier 40
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1019 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 24V DC Loop Pwd By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-1019 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 4" STD 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 0-10 µs/cm
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1019 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media N/A
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
N/A
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Vendor 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 36
97 Model

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA 45
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 35 of 42
Tag Number: AT-1019

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Conductivity cell shall be provided with automatic temperature compensation.

3. Sample system enclosure rating to be IP 65, minimum.

4. Supplier to specify all consummables, including reagents and calibration materials.

5. Supplier shall recommend any equipment or accessories required for best operation and reliability.

6. This analyzer is to be installed in the field.

7. Number of streams measured: 1

8. Range to be confirmed during Detail Engineering.

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 36 of 42
1 Tag Number AT-4019
2 Service 118-J/JA CONDENSATE PUMP OUTLET
GENERAL
3 Application Equipment No. LIQ. CONDUCTIVITY ANALYZER N/A
4 Line No. P & ID No. SC4003-6" (01CB1S02) 64-D105C
5 Fluid STEAM CONDENSATE 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 110,970 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 49 51 Deg C 29 Conductivity µS/cm 1.00 3.0 0-10
9 Pressure 7.27 kg/cm2 (g) 30
10 Density 988.00 kg/m³ 31
11 Viscosity 0.554 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 H2O 100 100 100 %
17 Line Length By Supplier 38
Sample
18 Tap Connection By Supplier 39
17 Piping Size By Supplier 40
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-4019 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 24V DC Loop Pwd By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-4019 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 6" XS 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 0-10 µs/cm
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-4019 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media N/A
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
N/A
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Vendor 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 38
97 Model

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 37 of 42
Tag Number: AT-4019

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Conductivity cell shall be provided with automatic temperature compensation.

3. Sample system enclosure rating to be IP 65, minimum.

4. Supplier to specify all consummables, including reagents and calibration materials.

5. Supplier shall recommend any equipment or accessories required for best operation and reliability.

6. This analyzer is to be installed in the field.

7. Number of streams measured: 1

8. Range to be confirmed during Detail Engineering.

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 38 of 42
1 Tag Number AT-1007
2 Service 101-U DEAERATOR BFW OUTLET
GENERAL
3 Application Equipment No. pH ANALYZER N/A
4 Line No. P & ID No. BW1001-14" (01CB1S02) 64-D106
5 Fluid BOILER FEED WATER 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 283,540 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 130 ºC 29 BFW pH 7.00 9.0 2-12
9 Pressure FV 1.75 kg/cm2 (g) 30
10 Density 934.30 kg/m³ 31
11 Viscosity 0.212 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 N/A
17 Line Length By Supplier 38
Sample
18 Tap Connection By Supplier 39
17 Piping Size By Supplier 40
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1007 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 24V DC Loop Pwd By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 0.2% of Full Scale
50 54
55 Tag Number AE-1007 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 14" STD 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 2-12 pH
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC Deg C 68 Accuracy in % N/A
69 Tag Number AI-1007 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media N/A
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
N/A
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Supplier 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 40
97 Model

PH ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 39 of 42
Tag Number: AT-1007

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Analyzer fast loop return will be connected to open drain.

3. To be confirmed during Detail Engineering.

4. Service water is available for sample cooling.

PH ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 40 of 42
1 Tag Number AT-1015
2 Service 101-U DEAERATOR BFW MAKEUP WATER
GENERAL
3 Application Equipment No. LIQ. CONDUCTIVITY ANALYZER N/A
4 Line No. P & ID No. DM1001-8" (01SA0S01) 64-D106
5 Fluid BFW WATER 26 Components to be Analyzed
6 Min Nor Max UOM 27 Concentration
7 Flow 307,120 kg/h 28 Component Unit Nor Max Calib.Range
8 Temperature 116 Deg C 29 Conductivity µS/cm 0.50 <2 0-10
9 Pressure 1.75 kg/cm2 (g) 30
10 Density 945.60 kg/m³ 31
11 Viscosity 0.239 cP 32
12 Conductivity 33
PROCESS 13 Sample Type N/A 34 Other Components
COND. 14 Contaminant Particle Size N/A 35 Concentration(All Wet Basis)
15 Corrosive Sampling Rate N/A N/A 36 Component Min Nor Max Uom
16 Contact Materials Note 1 37 H2O 100 100 100 %
17 Line Length By Supplier 38
Sample
18 Tap Connection By Supplier 39
17 Piping Size By Supplier 40
19 Design Pressure By DEC 41
21 Design Temperature By DEC 42 Description Qty. Consumption
22 Type By Supplier 43 By DEC
23 Concentration By Supplier 44 Required Reagents
24 Flow Rate By Supplier 45
25 46
47 Tag Number AT-1015 51 Mounting Signal By Supplier 4-20 mA+HART
TRANS- 48 Supply Volts Amps 24V DC Loop Pwd By Supplier 52 Enclosure Area Class IP 65 Min. By DEC
MITTER 49 Scale Indicating Type By Supplier By Supplier 53 Accuracy +/- 1% of Full Scale
50 54
55 Tag Number AE-1015 62 Model No. By Supplier
56 Supply Volts Amps N/A N/A 63 Size Type | Rating By Supplier
SENSOR/ 57 Line Size Schedule 8" 10S 64 Process Connection 3/4" NPT
ELEMENT 58 Oper. Temp Max | Min By DEC By DEC 65 Measuring Range 0-10 µs/cm
59 Material By DEC 66 Enclosure IP 65 Min.
60 Max Design Pressure By DEC kg/cm2 (g) 67 Area Class. By DEC
61 Max Design Temperature By DEC ºC 68 Accuracy in % N/A
69 Tag Number AI-1015 82 Enclosure IP 65 Min.
70 Supply V | A | Hz 83 Area Class. By DEC
71 Variations Limits V |A 84 Tag No. N/A
Recorder
72 Mounting 85 Data Sheet N/A
73 Outputs 86 Ambient Temp. Range 20 / 35 Deg C
74 Dimension Wdth | Dpth | Hght 87 Lighting Level By DEC
MONITOR 75 Indicating Scale 88 Direct Sunlight Strikes By DEC
76 Scale Type 89 Purge Media N/A
77 Required Response Time 90 Min Nor Max UOM
78 Accuracy In % 91 Flow
79 Contacts 92 Temperature
N/A
80 Contacts Rat. V | A | Hz 93 Pressure
81 94 Density
95 Vendor 98 Purchase Order Number By DEC
PURCHASE 96 Manufacturer By DEC 99 Remarks See Notes on Page 42
97 Model

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 41 of 42
Tag Number: AT-1015

NOTES:

1. Supplier shall be responsible for selection of contact material based on the process fluid properties.

2. Conductivity cell shall be provided with automatic temperature compensation.

3. Sample system enclosure rating to be IP 65, minimum.

4. Supplier to specify all consummables, including reagents and calibration materials.

5. Supplier shall recommend any equipment or accessories required for best operation and reliability.

6. This analyzer is to be installed in the field.

7. Number of streams measured: 1

8. Range to be confirmed during Detail Engineering.

9. Service water is available for sample cooling.

CONDUCTIVITY ANALYZER
Client: PT PANCA AMARA UTAMA
Project: 1900 MTPD AMMONIA PROJECT
Location: CENTRAL SULAWESI, INDONESIA
P00 MM BBK RT 29-Jun-15 RE-ISSUED FOR DESIGN Unit: AMMONIA
0 NSB YL RT 27-Apr-13 ISSUED FOR DESIGN Drawing No.: F283-IC-DAS-II0-0001
Rev By Chk Appr Date Revision Description Spec Form No. 100 Sheet 42 of 42