1000
1000
20 NOS.12mm TOR
COLUMN
1000
CL. 8 NOS. M30 x 1000mm LONG BOLTS
300
FGL. FGL.
CABLE ENTRY
PVC PIPE ANCHOR PLATE .
2000
R.C.C 1 : 1.5 : 3
300
R.C.C 1 : 1.5 : 3
100
P.C.C 1 : 4 : 8
3200
SECTIONAL ELEVATION
3200
PLAN
100
01 20 12mm 2600
2200
TOR
300
100
02 2x19 12mm 3000
TOR NOTES:-
2800
900
03 12 8mm 3650 1. ALL DIMENSIONS ARE IN MM.
TOR 2. STRUCTURAL CONCRETE SHALL HAVE CURING FOR 28 DAYS
50
900 3. MINIMUM COMPRESSIVE DESIGN STRENGTH SHALL HAVE 200KG Sq CM
4. REINFORCEMENT SHALL BE HYSD BARS CONFORMING TO Fe-500
5. SBC CONSIDERED AT 3.0 M DEPTH BELOW GL IS 5 MT / Sq M
100
04 4x7 10mm 3000
TOR
2800
900
05 06 8mm 2750
TOR
450
50
DRG No.008
DRG No.007
1200 mm
9 MTR HIGH GALVANIZED OCTAGONAL POLE Sl. No Height (H) Top Dia Bottom Dia Thickness of Base Plate Fdn. Bolt
in mm (T.D in mm) (B.D in mm) Pole (t in mm) SXSXTmm NoxDia.xLen.
T.D.
15 Deg
1 9000 90 190 4mm 300x300x16 4 x 24 x 750
TO
40 NB (Med) PIPE FIXTURE
+
25 NB (Med) PIPE All dimensions are in mm
-
450 mm
10 Amp SP MCB 4 Nos Foundation Bolt
24 mm Dia 750 Long
300 mm
G.L G.L
Neutral Link
Vertical 12 mmTOR
63 A 4 WAY 8 Nos @ 175 mm
STUD CONNECTOR
R.C.C(1:2:4)
Dia
200 mm
100
t mm THK.
H 3 Nos of Nut
with 2 No Pack Washer
P.C.C(1:4:8) 100mm
1200 mm
Length
FOUNDATION BOLT
1200mm
S
HOLE FOR Raft 10 mm TOR Rods
4 Nos Fdn Bolt @ 150 C/C Bothways
Rib Plate.
S B.D
BASE PLT.
SXSXTmm THK.
B.D.
DRAWING
NO-006