Overview Camera(s)
Connect a network switch to the Gigabit LAN 1 connector at the rear of the MAXPRO NVR SE unit. Connect your
This document covers how to: cameras either to the network switcher or to other Ethernet network connections in your system with CAT5 Ethernet
cables.
• Connect essential hardware to a MAXPRO NVR SE (PAL) unit.
• Configure network settings, set up IP addresses, and discover connected devices.
• Configure the unit to record video.
Note More detailed MAXPRO NVR SE documentation is available on the Documentation DVD included with
your unit.
• Power cord • This Quick Install Guide • Optional, additional hard drive(s)
• Keyboard (PS/2) • Recovery DVD • 8 or more screws for hard drive
• Mouse (PS/2) • Rail hardware kit with instructions installation
• DVI and VGA cable adapters for rack mount installations • MAXPRO NVR SE Software and DVI/VGA DVI/VGA
Documentation DVD MAXPRO NVR SE
Note Other peripheral hardware (owner supplied) will also be needed for your installation (such as cameras, network
equipment and an optional keyboard controller). See 2 Installing Unit, for more information.
Processor Intel® Core™ 2 Duo Processor E6750 2.66 GHz or Quad Core Intel® Xeon®
E5405 2.0 GHz (faster speeds are optional)
CAT5e CAT5e
Operating System Microsoft® Windows® 7 Professional CAT5e
System Memory (RAM) 4 GB of RAM minimum
DVD Drive DVD-RW drive. An RW (Read Write) drive is required if the workstation is used
for exporting recordings.
HD4DIP HD3MDIP HCD554IP
Disk Single Disk or RAID 0 or 0+1 10K SATA 80 GB or 10K to 15K SAS 73 GB with
Windows Operating System
Monitor(s)
Multiple Monitor Card – 1 x 256 MB PCIe x 16 NVIDIA Quadro NVS 285, Dual DVI or Dual VGA or
Display Adapter DVI+VGA. This is for a two monitor setup with each monitor requiring 128 MB. The MAXPRO NVR SE comes with a dual graphics card, so two monitors can be connected. A DVI monitor is best-
suited for viewing live video. Connect the monitor to the supplied DMS-59 to dual DVI adapter cable, then connect the
Network Connection 1 Gigabit/sec Network Interface Card (NIC) or greater cable to the DMS-59 connector (2) on the rear panel of the unit. Do not use the HDMI (7) or VGA (6) graphics ports as
these are disabled. The recommended settings for your monitor are: 1280 x 1024 pixels (resolution), and 65K colors
Video Resolution 1280 x 1024 pixels (resolution), 65K colors non-interlaced (color quality). Please
refer to the MAXPRO® NVR SE Commissioning and Installation Guide for more non-interlaced (color quality). Refer to the MAXPRO® NVR Commissioning and Installation Guide for more information
information on configuring monitor properties. on configuring the monitor display properties.
~ ~
3 Connecting Hardware
Rear Panel Connections No. LEDs, Buttons Behavior
1 Power Failure LED Flashing = Indicates a power failure in the power supply.
1
2 Overheat/Fan Flashing = Indicates a fan failure.
Failure LED Continuously on = Indicates the temperature has exceeded the threshold. This may be
caused by cables obstructing the airflow in the system or the ambient room temperature
being too warm. Check the cable routing and make sure all fans are present and
operating normally. You should also check that the chassis covers are installed. Finally,
verify that the heatsinks are installed properly. The LED will continue to flash or be on as
long as the overheat condition exists.
3 NIC2 LED Flashing = There is network activity on GLAN2.
4 9 3 6 9 9 7 6
8 4 NIC1 LED Flashing = There is network activity on GLAN1.
5 2
8
5 HDD LED Flashing = Indicates IDE channel activity in the SAS/SATA drive, SCSI drive and/or DVD-
ROM drive.
# Connector Connects to...
1 Power Electrical outlet 6 Power LED On = Indicates power is being supplied to the system’s power supply units. This LED
2 DMS-59 Pin PC video card should normally be illuminated when the system is operating.
3 DB-9 Pin Serial port Various devices
4 DIN-8 Connector PC PS/2 Mouse 7 Reset Button Press to reboot the system.
5 DIN-8 Connector PC PS/2 Keyboard
6 DB-15 VGA Connector Monitor
8 Power Button The main power switch is used to apply or remove power from the power supply to the
7 HDMI Monitor server system. Turning off system power with this button removes the main power but
8 USB Ports Various devices keeps standby power supplied to the system. Therefore, you must unplug the system
9 Gigabit LAN 1 Network before servicing.
9, HDD Activity/Failure Green = Indicates drive activity.
10 LEDs Red = Indicates a drive failure. If a drive fails you should be notified by your system
management software.
MAXPRO NVR SE has one default Windows user configured: Administrator (user name Administrator, password Enable/Disable Used to enable or disable a camera for recording and live view.
Password1) with full operation and configuration privileges and one default non-Windows user (user name admin, Number Displays the camera number.
password trinity). Both user names and passwords are case-sensitive.
Camera Name Type a new camera name (maximum 18 alphanumeric characters).
Logging On and Off IP Address Displays the default IP address of the camera.
Note This is the IP address the NVR will use to connect to the camera. Changing this
1. Double-click on the desktop. At the prompt, log on. value does not change the actual IP address of the camera.
2. Select Display Video on Alarm to display the viewer as an alarm
Camera Type Displays the type of camera.
monitor.
3. Click . The Viewer screen appears by default. Fixed/PTZ Indicates whether the camera is a PTZ or fixed camera.
Note If the NVR name has been changed, please click Cancel Continuous Recording The default is 24/7 recording. Select a different option from the drop-down list.
and then click Server settings. You will be able to Event Based Recording Select an event based recording from the drop-down list. The default is None.
change the Server IP/Name you are connecting to in this Choose a schedule if, for example, you are doing motion-based recording only.
window. Save this as your default profile.
User Name Select to change the default user name (admin) for the camera.
6 Camera and MAXPRO NVR SE IP Addresses Camera Advanced Settings 1. Click to open the Camera Advanced Settings pane. This pane is disabled
when there are no cameras available in the system.
2. Click Launch Web View for Advanced Set Up.
Use the IP Utility to set the IP Address for each connected camera in your network before you add them (see 8 Setting
Up the Cameras). Click on the desktop. After logging on, the IP Utility automatically discovers connected cameras. Use the web client to view IP and firmware settings, bit rate statistics, camera
Select a camera in the list on the left pane. Confirm that the camera is using a static IP address (not DHCP). exposure, day night and white balance settings, and set up video motion detection
and other analytic events.
Your MAXPRO NVR SE unit comes with a default IP Address (192.168.1.101) and computer name (MaxPRO-NVR). If Note Camera compression settings should be set from the MAXPRO NVR software
you are going to have more than one MAXPRO NVR SE on the network then you should change the computer name as changes made in the web client will be overwritten.
and IP address. Each MAXPRO NVR SE unit should have its own unique computer name and IP address.
Live Quality Settings Select to change the following:
1. To change the computer name using Windows:
Video Format: Select NTSC or PAL as applicable.
a. Navigate to Start Computer Properties Change settings, then click Change. Compression Format: Select to change the default format.
b. Type in a new computer name. Do not use the following characters: < > ; : " * + = \ | ?. Also, the name Resolution: Select to change the default resolution (camera model dependent).
should not contain spaces or all numbers. PTZ Sensitivity: For PTZ cameras, select from Low, Normal, High, Maximum.
c. Launch MAXPRO NVR SE, then on the System tab (Configurator tab System tab) in the Device Address Compression: Select to change the default Medium ratio. The higher the
field, add the new computer name and reboot. compression, the lower the bit rate, the lower the image quality and the more
processor power is consumed.
2. To change the IP address using Windows: FPS: For live streaming, default frame rates are 30 FPS (NTSC) / 25 FPS (PAL).
a. Click the network icon located next to the clock (lower right of screen) Open network and sharing center GOP: Select a new GOP from 0 to 100 (default 16). For example:
Change adapter settings.
Live settings Record quality resulting FPS
b. Right click Local area connection and select Properties.
FPS GOP Every I frame Every 2nd I frame Every 3rd I frame
c. Click Internet Protocol Version 4 (TCP/IPv4), then click Properties.
30 2 15 7.5 5
d. It is recommended that you use static IP address scheme.
30 16 1.88 0.94 0.63
e. Click Use the following IP address, then in the IP address, Subnet mask, and Default gateway boxes, type
the IP address settings. 30 30 1 3.5 0.33
f. Specify preferred and alternate DNS server address. This step is required when clients connect through the
Internet. Recording Quality Settings Select the FPS for Background and Event based recording.
Clip Deletion Settings Select the Event Recording or Background Recording clip deletion duration.
7 System Settings 4. To delete a camera, select the clear the check box next to that camera, then click Delete and Yes.
5. Click Save. If you have changed the Camera Advanced Settings, click Apply first.
Schedule Create schedules for camera(s) to record video at recurring intervals for continuous recording or event based
recording (for example, motion event). There are four default schedules: 24 x 7, Weekday, DayTime, NightTime.
Sequence Create a set of live video streamed one after the other from two or more cameras for a specified time interval. You
can select cameras or presets to be included in a sequence. You can also specify the time interval (Dwell Time
(Sec)) for which the video from each camera or preset must be displayed before advancing to the next camera.
User The default user (admin), that was created when the MAXPRO NVR SE software was installed, has the role
NVRAdministrator. The NVRAdministrator has access to all tabs. The Supervisor user has access to View,
Search and Report tabs. The Operator user has access to only the View tab. Events are associated to users on
the User tab.
2. Click Add to add all the discovered cameras. To add only specific cameras, first clear the check boxes of the
cameras you do not wish to add.
3. In the Cameras pane, select a camera to change the default parameters, following the table below.
© 2011 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any means without written www.honeywellvideo.com
permission from Honeywell. The information in this publication is believed to be accurate in all respects. However, Honeywell cannot +1.800.796.CCTV (North America only)
assume responsibility for any consequences resulting from the use thereof. The information contained herein is subject to change HVSsupport@honeywell.com