Sie sind auf Seite 1von 68

fåëí~ää~íáçåI=j~áåíÉå~åÅÉ=~åÇ=pÉêîáÅÉ=mêçÅÉÇìêÉë

lêáÖáå~ä=açÅìãÉåí~íáçå=L=hÉÉé=Ñçê=cìíìêÉ=oÉÑÉêÉåÅÉ

dóêçëéÜÉêÉLP=EãÉêÅìêó=ÑêÉÉF=L
dóêçëéÜÉêÉ=`çåí~áåÉê=jçÇK=NMLP

Ñçê
aáÖáí~ä=dóêçÅçãé~ëë=póëíÉãë
k^sfd^q==u=jh==N=~åÇ=k^sfd^q==u=jh==O
MMRMMMJMNORJMMN=oÉîK=`
NN=kçî=OMNP
kçêíÜêçé=dêìãã~å=péÉêêó=j~êáåÉ=_KsK=EoÉéêÉëÉåí~íáîÉ=lÑÑáÅÉF
tçäíã~åëíêK=NV=√=aJOMMVT=√=e~ãÄìêÖI=dÉêã~åó
qÉäKW==HQVJQMJOVV=MMJM=√=c~ñW==HQVJQMJOVV=MMJNQS=√=bJã~áäW==ëÉêîáÅÉKÉì]ëéÉêêóKåÖÅKÅçã
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

© 2013 Northrop Grumman Sperry Marine B.V.


This document and the information herein is the intellectual property of Northrop Grumman
Sperry Marine B.V. [NGSM BV] and it’s associate companies and may not be copied, reproduced
or translated without the express permission of NGSM BV.
Specifications were correct at time of press but may be varied in accordance with NGSM BV’s
policy of continuous product development.
Any technical content should be verified with NGSM BV.

Sperry Marine, with major engineering and support offices in New Malden, England, and
Hamburg, Germany, is part of the Northrop Grumman Navigation & Maritime Systems Division
N&MSD.

oÉîáëáçå=oÉÅçêÇ

oÉîK a~íÉ=çÑ=fëëìÉ oÉã~êâë


C 11 Nov 2013 Power-up function test amended.

B 11 Sep 2013 Updated and amended version; maintenance procedures


updated, replacement of optical pick-offs PCBs added, installa-
tion checklists added, spare parts added.

A 03 Oct 2006 Initial version. This document replaces the installation/service


instructions formerly included in gyrocompass manuals.
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

`çåíÉåíë

p~ÑÉíó=fåëíêìÅíáçåë
p~ÑÉíó=kçíáÅÉ=`çåîÉåíáçåë=KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK R
dÉåÉê~ä=p~ÑÉíó=fåÑçêã~íáçå=Ñçê=íÜÉ=léÉê~íçê= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK S
dÉåÉê~ä=p~ÑÉíó=fåÑçêã~íáçå=Ñçê=pÉêîáÅÉ=mÉêëçååÉä=KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK U

fåíêçÇìÅíáçå
póëíÉã=lîÉêîáÉï=~åÇ=j~áå=`çãéçåÉåíë= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKNN
qê~åëéçêí= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NP
e~åÇäáåÖ=ÇìêáåÖ=fåëí~ää~íáçå=~åÇ=pÉêîáÅÉ= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NQ
píçê~ÖÉ=KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NQ

lîÉêîáÉï=çÑ=mêçÅÉÇìêÉë
cáêëí=íáãÉ=fåëí~ää~íáçå=KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NR
NUJãçåíÜ=j~áåíÉå~åÅÉ= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NR
dóêçëéÜÉêÉ=oÉéä~ÅÉãÉåí=L=ÑáîÉJóÉ~ê=j~áåíÉå~åÅÉ=KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NR
lîÉêîáÉï=çÑ=mêçÅÉÇìê~ä=píÉéë= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NS

dóêçëéÜÉêÉ=fåëí~ää~íáçå
mêÉé~êáåÖ=íÜÉ=`çåí~áåÉê=Ñçê=Ñáêëí=íáãÉ=fåëí~ää~íáçå= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NT
fåëí~ääáåÖ=íÜÉ=dóêçëéÜÉêÉ=áå=íÜÉ=`çåí~áåÉê= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK NV
fåëí~ääáåÖ=íÜÉ=`çåí~áåÉê=áå=íÜÉ=dóêçÅçãé~ëë=KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK OP

dóêçëéÜÉêÉ=oÉãçî~ä
oÉãçîáåÖ=íÜÉ=`çåí~áåÉê=Ñêçã=íÜÉ=dóêçÅçãé~ëë= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK OT
oÉãçîáåÖ=íÜÉ=dóêçëéÜÉêÉ=Ñêçã=íÜÉ=`çåí~áåÉê= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK PM

dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë
dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK PP
dóêçëéÜÉêÉ=`çåí~áåÉê=j~áåíÉå~åÅÉ= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK PR

mêÉé~êáåÖ=oÉJfåëí~ää~íáçå=L=qê~åëéçêí
mêÉé~êáåÖ=íÜÉ=dóêçëéÜÉêÉ=Ñçê=oÉJfåëí~ää~íáçå=KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK QP
mêÉé~êáåÖ=íÜÉ=dóêçëéÜÉêÉ=Ñçê=qê~åëéçêí=KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK QP
mêÉé~êáåÖ=íÜÉ=`çåí~áåÉê=Ñçê=oÉJfåëí~ää~íáçå= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK QQ

cáêëíJíáãÉ=léÉê~íáçå
mçïÉêJìé=ÑìåÅíáçå=íÉëí= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK QR

m~ÖÉ=P
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

pé~êÉ=m~êíë
fääìëíê~íÉÇ=m~êíë=iáëí=EfmiF=lîÉêîáÉï= KKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKKK RP

^ééÉåÇáñ

m~ÖÉ=Q
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

p~ÑÉíó=fåëíêìÅíáçåë

p~ÑÉíó=kçíáÅÉ=`çåîÉåíáçåë
The following safety notice conventions are followed throughout this
manual:

a^kdbo A a~åÖÉê notice begins with the named type of


danger and contains an operating or mainte-
nance procedure, practice, condition, statement,
etc., which, if not strictly observed, ïáää=êÉëìäí=áå=
áåàìêó=çê=ÇÉ~íÜ=çÑ=éÉêëçååÉäK

t^okfkd A t~êåáåÖ notice begins with the named type of


warning and contains an operating or mainte-
nance procedure, practice, condition, statement,
etc., which, if not strictly observed, ÅçìäÇ=êÉëìäí=
áå=áåàìêó=çê=ÇÉ~íÜ=çÑ=éÉêëçååÉäK

`^rqflk A `~ìíáçå notice begins with the named type of


caution and contains an operating or mainte-
nance procedure, practice, condition, statement,
etc., which, if not strictly observed, ÅçìäÇ=êÉëìäí=
áå=Ç~ã~ÖÉ=íçI=çê=ÇÉëíêìÅíáçå=çÑ=ÉèìáéãÉåíK

kçíÉ A kçíÉ contains an essential operating or main-


tenance procedure, condition or statement,
which is considered important enough to be
highlighted.

Special safety symbols may be used in this


manual to indicate:

oáëâ=çÑ=ÉäÉÅíêáÅ~ä=ëÜçÅâK
Used in conjunction with a a~åÖÉê or t~êåáåÖ
notice.

Electrical components sensitive to electrostatic


discharge.
Used in conjunction with a `~ìíáçå notice.

R
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

dÉåÉê~ä=p~ÑÉíó=fåÑçêã~íáçå=Ñçê=íÜÉ=léÉê~íçê

`^rqflk Risk of damage through unauthorized service


Any service and installation work on the gyrosphere is to be carried out
by authorized service personnel only.
Never undertake service or installation work if unskilled for the certain
procedure.

`^rqflk Risk of mercury contamination


The gyrosphere type 3 and the gyrosphere container mod. 10/3 are
designed for mercury free operation. Any usage of mercury will severely
contaminate the gyrosphere type 3 / gyrosphere container mod. 10/3.
Never use mercury with the gyrosphere type 3 and the gyrosphere con-
tainer mod. 10/3.
In case of usage of mercury by mistake, the contaminated equipment
must not be used and all safety instructions of the Sperry Marine Mer-
cury Handling Procedure 026150-0000-000 must be followed accordingly.

`^rqflk Risk of defective gyrosphere


The gyrosphere may not be in operable working condition, if after a time
period of around 45 minutes after power-up the gyrosphere current has
not dropped below 320 mA.
If a visual inspection reveals no obvious cause of malfunction, the power-
up cycle of the gyrosphere must be completely repeated.
If after a time period of around 45 minutes after the second power-up
cycle the gyrosphere current has still not dropped below 320 mA, the
gyrosphere may not be in operable working condition.
Contact the Sperry Marine Service for advice.

`^rqflk Risk of misleading gyrosphere data / operating values


The temperature and gyrosphere current values are indicated as reading
values at the CDU only.
Both values can be adjusted via correction values, which are set to neu-
tral (= no correction) values by default.
Therefore the indicated values may deviate from real gyrosphere operat-
ing values, which can only be measured at the required checkpoints by
authorized service personnel.

`^rqflk Risk of inadequate correction values


Any wrongful or not instructed adjustment of the temperature and gyro-
sphere correction values will falsify a correct identification of the
NAVIGAT X MK1 / MK2 system‘s operating conditions.
Only authorized service personnel is allowed to change the temperature
and gyrosphere current correction values.
Never alter the correction values unless specifically instructed by Sperry
Marine.

kçíÉ This Installation, Maintenance and Service Procedures apply with the fol-
lowing separate Operation, Installation and Service Manuals:
- 056343, NAVIGAT X MK1, Digital Gyrocompass System
- 056341, NAVIGAT X MK2, Digital Gyrocompass System.

S
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

kçíÉ All information within this Installation, Maintenance and Service Proce-
dures apply for the:
NAVIGAT X MK1, Digital Gyrocompass System and the
NAVIGAT X MK2, Digital Gyrocompass System,
if not explicitly mentioned otherwise.

kçíÉ Sperry Marine Service:


In case of service refer to www.sperrymarine.com/offices for a list of all
Sperry Marine Offices and Service Agents worldwide.

T
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

dÉåÉê~ä=p~ÑÉíó=fåÑçêã~íáçå=Ñçê=pÉêîáÅÉ=mÉêëçååÉä

a^kdbo iáÑÉ=Ç~åÖÉê=íÜêçìÖÜ=ÉäÉÅíêáÅ~ä=ëÜçÅâ
tÜÉå=íÜÉ=ÖóêçÅçãé~ëë=áë=ÉåÉêÖáòÉÇI=íÜÉ=ÖóêçëéÜÉêÉ=çéÉê~íáåÖ=îçäí~ÖÉ=
çÑ=NMM=s^`=]=PPT=eò=áë=éêÉëÉåí=çå=íÜÉ=ã~ëíÉê=m`_I=íÜÉ=ÖóêçëéÜÉêÉ=ëìéJ
éäó=äáåÉëI=~åÇ=~Åêçëë=íÜÉ=ÖóêçëéÜÉêÉ=Åçåí~ÅíëK=
tÜÉå=íÜÉ=^`=ã~áå=ëìééäó=áë=ëïáíÅÜÉÇ=çåI=Ü~ò~êÇçìë=äáÑÉ=îçäí~ÖÉë=~êÉ=
éêÉëÉåí=~í=íÜÉ=äáåÉ=ÑáäíÉê=~åÇ=íÜÉ=éçïÉê=íê~åëÑçêãÉêÛë=íÉêãáå~äëK
j~âÉ=ëìêÉ=íÜ~í=íÜÉ=ã~áå=~åÇ=Ä~Åâìé=éçïÉê=ëìééäáÉë=çÑ=íÜÉ=ÖóêçÅçãé~ëë=
~êÉ=~äï~óë=ëïáíÅÜÉÇ=çÑÑ=~åÇ=ë~ÑÉÖì~êÇÉÇ=~Ö~áåëí=~ÅÅáÇÉåí~ä=ëïáíÅÜáåÖJ
çå=ÄÉÑçêÉ=ìåÇÉêí~âáåÖ=~åó=êÉãçî~ä=çê=áåëí~ää~íáçå=éêçÅÉÇìêÉë=çÑ=íÜÉ=
ÖóêçëéÜÉêÉ=Åçåí~áåÉêK

a^kdbo iáÑÉ=Ç~åÖÉê=íÜêçìÖÜ=ÉäÉÅíêáÅ~ä=ëÜçÅâ
tÜÉå=íÜÉ=ÖóêçÅçãé~ëë=áë=ÉåÉêÖáòÉÇI=íÜÉ=ÖóêçëéÜÉêÉ=çéÉê~íáåÖ=îçäí~ÖÉ=
çÑ=NMM=s^`=]=PPT=eò=áë=éêÉëÉåí=çå=íÜÉ=ã~ëíÉê=m`_I=íÜÉ=ÖóêçëéÜÉêÉ=ëìéJ
éäó=äáåÉë=~åÇ=~Åêçëë=íÜÉ=ÖóêçëéÜÉêÉ=Åçåí~ÅíëK=
tÜÉå=íÜÉ=^`=ã~áå=ëìééäó=áë=ëïáíÅÜÉÇ=çåI=Ü~ò~êÇçìë=äáÑÉ=îçäí~ÖÉë=~êÉ=
éêÉëÉåí=~í=íÜÉ=äáåÉ=ÑáäíÉê=~åÇ=íÜÉ=éçïÉê=íê~åëÑçêãÉêÛë=íÉêãáå~äëK
_É=ÉñíêÉãÉäó=Å~êÉÑìä=ïÜÉå=çéÉê~íáåÖ=íÜÉ=ÖóêçÅçãé~ëë=ïÜáäÉ=íÜÉ=ÜçìëJ
áåÖ=áë=çéÉåK=kÉïÉê=íçìÅÜ=íÜÉ=ã~ëíÉê=m`_I=íÜÉ=ÅçååÉÅíáåÖ=Å~ÄäÉë=íç=íÜÉ=
ÖóêçëéÜÉêÉ=Åçåí~áåÉê=çê=~åó=çíÜÉê=ÅçåÇìÅíáîÉ=ÅçãéçåÉåíë=çå=íÜÉ=ÅçåJ
í~áåÉê=çê=áå=íÜÉ=ÖóêçÅçãé~ëë=ÜçìëáåÖK
^äï~óë=ÉñÅäìÇÉ=~åó=Åçåí~Åí=íç=ÉåÉêÖáòÉÇ=ÅçãéçåÉåíëK

`^rqflk Risk of damage/destruction after power-down


After power-down of the gyrocompass system, it may take up to
45 minutes for the gyroscopes to stop rotating and the gyrosphere is
therefore extremely sensible against any movement. Should the gyro-
sphere touch the wall of the container, the momentum of the rotating
gyroscopes will make it topple and damage the centre pin.
Avoid any movement of the gyrocompass system during power-down
time. Always be extremely careful in case the gyrosphere container must
be handled during power-down time.

`^rqflk Risk of damage/destruction through transport / wrong storing


When the container is temporarily stored away with the gyrosphere
installed, pack it into its original transport box or another suitable outer
package.
Always make sure that:
- the container is stored in an upright position,
- the temperature at the storage location cannot fall below 0° C,
- the container is not moved, tilted or subjected to shock.

`^rqflk Risk of damage to the gyrosphere


The gyrosphere is always to be transported in its original transport box.
Do not throw or drop the transport box.
The transport box is to be transported in an upright position only.

U
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

`^rqflk Risk of damage to the gyrosphere


Carry the transport box containing the gyrosphere by hand only and han-
dle it with extreme care.
Remove the gyroshpere from the transport box only if required for imme-
diate installation.

`^rqflk Risk of damage


When assembling the gyrosphere container, make sure not to damage
the centering pin in the top section of the container.
Check that the gyrosphere is positioned upright in the bottom section of
the container. Do not skew the top section when fitting.

`^rqflk Risk of damage to the gyrosphere through pollution


Any pollution of the gyrosphere will negatively impact the functionality
and service life period of the Gyrosphere/3 gyrocompass system.
Never pollute the gyrosphere during installation or removal procedures.
Always maintain a clear workplace and handle the gyrosphere with
clean, thoroughly washed hands only.

`^rqflk Risk of damage through improper cleaning liquids


Normal water can be polluted and contain germs and algae, which can
easily reproduce in the supporting fluid warming up in operation, caus-
ing pollution and improper working conditions to the gyrosphere.
Never use normal water or other improper cleaning liquids for cleaning
the gyrosphere or the container.

kçíÉ Residual supporting fluid may be used as an alternative cleaning liquid


R
when still clear and in good condition.

`^rqflk Risk of damage to the gyrosphere through wrong supporting fluid


The official supporting fluid is an immanent part of the Gyrosphere/3
gyrocompass system. Operating the gyrosphere with wrong supporting
fluid will severely impact the functionality and service life period of the
Gyrosphere/3 gyrocompass system and damage the gyrosphere.
Never use old supporting fluid or supporting fluid of unknown origin.
Always make sure to only use the official Sperry Marine supporting fluid.

`^rqflk Risk of damage


Carry the container with the gyrosphere by hand only and handle it with
extreme care. Always keep the container in an upright position. Avoid
any sudden or shock-like movements.

`^rqflk Risk of damage to the optical pick-offs flat cable connection


Any damage to the flat cable connecting the J3 connector of optical pick-
off PCB 1 with the J2 connector of optical pick-off PCB 2 will cause mal-
function to the gyrosphere.
A damaged flat cable can not be ordered as separate spare part.
Always handle the flat cable with care and be careful not to damage the
flat cable during replacement of the optical pick-offs.

V
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

`^rqflk Risk of defective gyrosphere caused by “GYRO FAILURE”


Should a “GYRO FAILURE” alarm occur during power-up, the gyrocom-
pass is not working properly.
De-energize the system and visually check the connections to the gyro-
sphere, the follow-up step motor and the shaft encoder.
If the failure reoccurs when the gyrocompass is powered-up again, the
installation has not been carried out correctly or the gyrosphere is defec-
tive and must be replaced.

`^rqflk Risk of defective gyrosphere


The gyrosphere may not be in operable working condition, if after a time
period of around 45 minutes after power-up the gyrosphere current has
not dropped below 320 mA.
If a visual inspection reveals no obvious cause of malfunction, the power
up cycle of the gyrosphere must be completely repeated.
If after a time period of around 45 minutes after the second power-up
cycle the gyrosphere current has still not dropped below 320 m, the gyro-
sphere may not be in operable working condition.
Contact the Sperry Marine Service for advice.

`^rqflk Risk of mercury contamination


The gyrosphere type 3 and the gyrosphere container mod. 10/3 are
designed for mercury free operation. Any usage of mercury will severely
contaminate the gyrosphere type 3 / gyrosphere container mod. 10/3.
Never use mercury with the gyrosphere type 3 and the gyrosphere con-
tainer mod. 10/3.
In case of usage of mercury by mistake, the contaminated equipment
must not be used and all safety instructions of the Sperry Marine Mer-
cury Handling Procedure 026150-0000-000 must be followed accordingly.

kçíÉ This Installation, Maintenance and Service Procedures apply with the fol-
lowing separate Operation, Installation and Service Manuals:
- 056343, NAVIGAT X MK1, Digital Gyrocompass System
- 056341, NAVIGAT X MK2, Digital Gyrocompass System

kçíÉ All information within this Installation, Maintenance and Service Proce-
dures apply for the:
NAVIGAT X MK1, Digital Gyrocompass System and the
NAVIGAT X MK2, Digital Gyrocompass System,
if not explicitly mentioned otherwise.

kçíÉ Make sure to have the current operating, installation and service manu-
als of the NAVIGAT X MK1 / NAVIGAT X MK2 systems at hand before
undertaking any installation, maintenance and service procedures on the
gyrosphere and gyrosphere container.

kçíÉ Make sure to include the gyrosphere service report, 04914-0126-05, when
returning a defective gyrosphere to Sperry Marine.
When the service report is not returned, no warranty exchange of the
gyrosphere is possible.

NM
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

N fåíêçÇìÅíáçå

NKN póëíÉã=lîÉêîáÉï=~åÇ=j~áå=`çãéçåÉåíë
cáÖìêÉ=NJNW
1
dóêçëéÜÉêÉ=`çåí~áåÉê=
jçÇK=NMLP

3
4 6

5
7

10

12
11

kçK fíÉã níóK


1 Fill plugs 2

2 Container top section 1

3 Top contact with center pin screw (not shown) 1

4 Optical pick-off PCB 2 1

5 Optical pick-offs flat cable connection (not shown) 1

6 J 1 plug connector of optical pick-off PCB 1 1

7 Optical pick-off PCB 1 1

8 Drain plug position (drain plug not shown) 1

9 Hex head screws 8

AT Container bottom section 1

AK Container type label 1

AL Base contact with plug connector 1

cáÖìêÉ=NJOW
`çåí~áåÉê=íóéÉ=ä~ÄÉä Electronic Systems
Sperry Marine

fåíêçÇìÅíáçå m~ÖÉ=NN
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

cáÖìêÉ=NJPW
dóêçëéÜÉêÉ=íóéÉ=P 1

kçK fíÉã níóK


1 Gyrosphere recess 1

2 Gyrosphere shell (in grey lacquer) 1

3 Reflection area (in white lacquer) 1

4 Gyrosphere bottom contact (not shown) 1

cáÖìêÉ=NJQW
léíáÅ~ä=éáÅâJçÑÑ=m`_=N

12041082

4991-4080-00 LG-Nr. 022578


Ser.-Nr: xxxx-xxx Rev X

3
2

Figure 1-4 shows front and rear side of the optical pick-off PCB 1 with J1,
J2 and J3 plug connectors, photoconductive cells 1, cooling plates 2
and PCB type label 3.

m~ÖÉ=NO fåíêçÇìÅíáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

cáÖìêÉ=NJRW
léíáÅ~ä=éáÅâJçÑÑ=m`_=O

12041093
4991-4080-00 LG-Nr. 022579
Ser.-Nr: xxxx-xxx Rev X

3
2

Figure 1-5 shows front and rear side of the optical pick-off PCB 2 with J2
and J3 plug connectors, photoconductive cells 1, cooling plates 2 and
PCB type label 3.

kçíÉ Differences between the optical pick-offs PCB 1 and PCB 2 are:
- Optical pick-off PCB 2 without J1 plug connector
- J3 plug connector not in use at optical PCB 2

NKO qê~åëéçêí

`^rqflk Risk of damage to the gyrosphere


The gyrosphere is always to be transported in its original transport box.
Do not throw or drop the transport box.
The transport box is to be transported in an upright position only.

The gyrosphere is contained in a specially designed transport box.


Within the transport box, the gyrosphere is secured at the bottom and
the top by two folded carton elements, each equipped with a transpar-
ent flexible foil for optimal shock protection. The transport box is suita-
ble for transport purposes by air, sea, rail and road.

For removing from or installing the gyrosphere into the transport box,
only the top carton element needs to become removed. The bottom car-
ton element does not need to become removed and may stay in the
transport box.

kçíÉ It is recommended to keep and store the empty original transport box
with the carton elements at a safe place, for any further packaging pur-
poses of the gyrosphere.

fåíêçÇìÅíáçå m~ÖÉ=NP
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

NKP e~åÇäáåÖ=ÇìêáåÖ=fåëí~ää~íáçå=~åÇ=pÉêîáÅÉ

`^rqflk Risk of damage to the gyrosphere


Carry the transport box containing the gyrosphere by hand only and han-
dle it with extreme care.
Remove the gyroshpere from the transport box only if required for imme-
diate installation.

`^rqflk Risk of damage/destruction when removing the gyrosphere container


from an installed gyrocompass after power-down
After power-down of the gyrocompass system, it may take up to
45 minutes for the gyroscopes to stop rotating and the gyrosphere is
therefore extremely sensible against any movement. Should the gyro-
sphere touch the wall of the container, the momentum of the rotating
gyroscopes will make it topple and damage the centre pin.
Avoid any movement of the gyrocompass system during power-down
time. Always be extremely careful in case the gyrosphere container must
be handled during power-down time.

`^rqflk Risk of damage to the gyrosphere through pollution


Any pollution of the gyrosphere will negatively impact the functionality
and service life period of the Gyrosphere/3 gyrocompass system.
Never pollute the gyrosphere during installation or removal procedures.
Always maintain a clear workplace and handle the gyrosphere with
clean, thoroughly washed hands only.

Upon installation, remove the gyrosphere from the transport box and
carry it by hand directly to the place of installation.

At the place of installation, a clean and level work surface must be avail-
able. The work surface must provide enough space for the gyrosphere
and the disassembled sections of the container to be placed next to each
other and their assembly, disassembly and cleaning to be carried out.

NKQ píçê~ÖÉ
Always store the gyrosphere in its original transport box at a protected
storage place with regards to the required environmental conditions.

båîáêçåãÉåí~ä=píçê~ÖÉ=`çåÇáíáçåë

• The temperature conditions of the storage place must be between


- 25° C and + 70° C.
• The humidity conditions in the storage place must be between
60% and 90%.
In case the storage duration of a gyrosphere exceeds the contractual
period of warranty and the gyrosphere is found in none operable condi-
tion after first installation, Sperry Marine reserves the right to decline
the acceptance of warranty.

m~ÖÉ=NQ fåíêçÇìÅíáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

O lîÉêîáÉï=çÑ=mêçÅÉÇìêÉë

The gyrosphere installation and service activities comprise a number of


step-by-step procedures which are explained separately in the following
chapters.

OKN cáêëí=íáãÉ=fåëí~ää~íáçå
The first time installation comprises the installation of a new gyrosphere
and container into the gyrocompass housing during the initial installa-
tion and configuration of the gyrocompass system.

⇒ For the first time installation of the gyrosphere see “Gyrosphere


Installation” on page 17.

OKO NUJãçåíÜ=j~áåíÉå~åÅÉ
The recommended 18-month maintenance comprises the removal of
the gyrosphere, cleaning and inspection of the gyrosphere, mainte-
nance of the gyrosphere container and the re-installation of the gyro-
sphere using fresh supporting fluid. If necessary, the centering pin is to
be replaced.

kçíÉ Sperry Marine recommends to have the optical pick-off PCBs exchanged
by default every second 18-month maintenance interval (= 36-month).

⇒ For the maintenance of the gyrosphere see “Gyrosphere Mainte-


nance” on page 33.

⇒ For the maintenance procedures of the gyrosphere container see


“Gyrosphere Container Maintenance” on page 35.

⇒ For the exchange of the optical pick-off PCBs, see “Replacement of


the Optical pick-off PCBs” on page 40.

OKP dóêçëéÜÉêÉ=oÉéä~ÅÉãÉåí=L=ÑáîÉJóÉ~ê=j~áåíÉå~åÅÉ
The replacement of a defective gyrosphere and the recommended five-
year maintenance both comprise the removal of the existing gyro-
sphere, maintenance of the gyrosphere container and the installation of
a new gyrosphere using fresh supporting fluid.
The centering pin is replaced routinely during the five-year maintenance
and during the replacement of a defective gyroshpere, if necessary.

kçíÉ The five-year exchange interval for the gyrosphere is a recommendation


only. As long as a gyrosphere is running flawlessly, the customer may
decide to keep it in service and have only the regular 18-month mainte-
nances carried out.

lîÉêîáÉï=çÑ=mêçÅÉÇìêÉë m~ÖÉ=NR
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

OKQ lîÉêîáÉï=çÑ=mêçÅÉÇìê~ä=píÉéë
cáÖìêÉ=OJNW
first-time regular maintenance or
dóêçëéÜÉêÉ=áåëí~ää~íáçå= installation gyrosphere replacement
~åÇ=ëÉêîáÅÉX=çîÉêîáÉï=çÑ=
éêçÅÉÇìê~ä=ëíÉéë
remove container from
compass housing

remove gyrosphere from


container

inspect container
condition

container
no
to be replaced?

yes

prepare old container


for transport

retrieve replacement
container

inspect gyrosphere
condition

gyrosphere
no
to be replaced?

yes

prepare old gyrosphere prepare gyrosphere


for transport for re-installation

retrieve replacement
gyrosphere

prepare container for prepare container


first-time installation for re-installation

install gyrosphere
in container

install container in
compass housing

conduct power-up
function test

function test
successful?
yes no

store service kit


and packaging;
put system back troubleshoot and
into normal operation service system

m~ÖÉ=NS lîÉêîáÉï=çÑ=mêçÅÉÇìêÉë
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

P dóêçëéÜÉêÉ=fåëí~ää~íáçå

PKN mêÉé~êáåÖ=íÜÉ=`çåí~áåÉê=Ñçê=Ñáêëí=íáãÉ=fåëí~ää~íáçå

m~êíëI=ã~íÉêá~äë=~åÇ=íççäë=êÉèìáêÉÇ

• the gyrosphere container Mod. 10/3, as delivered with the gyrocom-


pass
• a 4 mm hex key
• a calibrated torque wrench, for low level torque values around 1 Nm

mêçÅÉÇìêÉ

1. Unpack the gyrosphere container


from its transport box and place it
onto the work surface.

2. Control the torque of the center


pin screw with a calibrated torque
wrench whether a torque value of
1 Nm is applied.
⇒ Correct the torque if necessary.

3. Disconnect the plug connector


from the base contact.

dóêçëéÜÉêÉ=fåëí~ää~íáçå m~ÖÉ=NT
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

4. Unscrew the 4 mm hex-head


screws attaching the two halves of
the container.
Put the screws and washers aside.

5. Take off the top section of the con-


tainer and place it in an upright
position next to the lower section.
6. Continue now with the check pro-
cedure.

`ÜÉÅâ=mêçÅÉÇìêÉ

1. Control the torque of the center pin screw with a calibrated torque
wrench whether a torque value of 1 Nm is applied.
⇒ Correct the torque if necessary.

2. Control additionally, if the container top contact can be turned by


hand from the container housing inside.
⇒ When the torque of the center pin screw is correctly applied, the con-
tainer top contact cannot be turned by hand from the container
housing inside.

3. Check if the plug connector is disconnected from the base contact.


⇒ In case a step of the check procedure is not met as required, mend
the relevant installation condition to meet the requirements.

⇒ If all steps of the check procedure are met as required, proceed with
”Installing the Gyrosphere in the Container”.

m~ÖÉ=NU dóêçëéÜÉêÉ=fåëí~ää~íáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

PKO fåëí~ääáåÖ=íÜÉ=dóêçëéÜÉêÉ=áå=íÜÉ=`çåí~áåÉê

`^rqflk Risk of mercury contamination


The gyrosphere type 3 and the gyrosphere container mod. 10/3 are
designed for mercury free operation. Any usage of mercury will severely
contaminate the gyrosphere type 3 / gyrosphere container mod. 10/3.
Never use mercury with the gyrosphere type 3 and the gyrosphere con-
tainer mod. 10/3.
In case of usage of mercury by mistake, the contaminated equipment
must not be used and all safety instructions of the Sperry Marine Mer-
cury Handling Procedure 026150-0000-000 must be followed accordingly.

`^rqflk Risk of damage to the gyrosphere through pollution


Any pollution of the gyrosphere will negatively impact the functionality
and service life period of the Gyrosphere/3 gyrocompass system.
Never pollute the gyrosphere during installation or removal procedures.
Always maintain a clear workplace and handle the gyrosphere with
clean, thoroughly washed hands only.

`^rqflk Risk of damage to the gyrosphere through wrong supporting fluid


The official supporting fluid is an immanent part of the Gyrosphere/3
gyrocompass system. Operating the gyrosphere with wrong supporting
fluid will severely impact the functionality and service life period of the
Gyrosphere/3 gyrocompass system and damage the gyrosphere.
Never use old supporting fluid or supporting fluid of unknown origin.
Always make sure to only use the official Sperry Marine supporting fluid.

m~êíëI=ã~íÉêá~äë=~åÇ=íççäë=êÉèìáêÉÇ

• the gyrosphere, stock no. 74829 or 74831,


– as delivered in its transport box, for first-time installation or
gyrosphere replacement,
– or prepared for re-installation after regular maintenance, see
“Preparing the Gyrosphere for Re-Installation” on page 43.
• the container Mod. 10/3, stock no. 22561, disassembled into top and
bottom sections,
– as prepared for first time installation, see “Preparing the Con-
tainer for first time Installation” on page 17,
– or as prepared for re-installation, see “Preparing the Container
for Re-Installation” on page 44.
• the installation and replacement parts kit, stock no. 22638
• a 4 mm hex key
• a lint-free cloth or cleaning tissue

dóêçëéÜÉêÉ=fåëí~ää~íáçå m~ÖÉ=NV
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

mêçÅÉÇìêÉ

In case of immediate re-installation of the gyrosphere after regular


maintenance, skip steps 1 through 2 below.

1. Open the gyrosphere transport box and remove the top carton ele-
ment.
In case of a first-time installation or gyrosphere replacement, a label
carrying the gyrosphere’s serial number will be found in the recess
of the sphere. Affix this label to the gyrosphere container, next to the
container’s own label.

2. Placing a thumb in the recess of


the gyrosphere, carefully lift the
sphere out of the transport box.

3. Place the gyrosphere upright into


the bottom section of the con-
tainer.

4. Carefully fit the top section of the


gyrosphere container to the bot-
tom section. Three index pins pro-
trude from the top section, which
engage into corresponding holes
in the bottom section.

`^rqflk Risk of damage


When assembling the gyrosphere container, make sure not to damage
the centering pin in the top section of the container.
Check that the gyrosphere is positioned upright in the bottom section of
the container. Do not skew the top section when fitting.

m~ÖÉ=OM dóêçëéÜÉêÉ=fåëí~ää~íáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

5. Assemble the 4 mm hex-head


screws and washers attaching the
two halves of the gyrosphere con-
tainer.
Tighten the screws in a series of
diagonal opposites.

kçíÉ Be careful not to overtighten the 4 mm hex-head screws. The screws


need to become hand-tightened only.

6. Unscrew and remove the two fill


plugs from their holes in the top of
the container.

7. Make sure that the drain plug in


the bottom of the container is
tightened firmly.
⇒ See also “Inspection of drain plug
type” on page 35 for the correct
drain plug and joint type.

8. Take the bottle of supporting fluid


and the funnel from the installa-
tion kit. Open the bottle and
remove the seal from the neck.
9. Insert the funnel into one of the
filling holes and slowly fill up the
container with supporting fluid.
Stop filling when fluid exits from
the other hole.

10. Screw in the fill plugs and tighten them firmly by hand.
11. Wipe off any excess fluid from the outside of the container.
12. Reconnect the plug to the container’s base contact.
13. Proceed now with the check procedure.

dóêçëéÜÉêÉ=fåëí~ää~íáçå m~ÖÉ=ON
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

`ÜÉÅâ=mêçÅÉÇìêÉ

1. In case of a first-time installation or gyrosphere replacement, check


if the gyrosphere’s label is affixed to the container’s label.
2. Check if the 4 mm hex-head screws are hand-tight screwed.
3. Check the supporting fluid for correct filling level and if the fill plugs
are correctly tightened by hand.
4. Check the drain plug for watertightness and the container outside for
any excess fluid.
5. Check if the plug to the container’s base contact is reconnected.
⇒ In case a step of the check procedure is not met as required, mend
the relevant installation condition to meet the requirements.

⇒ If all steps of the check procedure are met as required, proceed with
”Installing the Container in the Gyrocompass”.

m~ÖÉ=OO dóêçëéÜÉêÉ=fåëí~ää~íáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

PKP fåëí~ääáåÖ=íÜÉ=`çåí~áåÉê=áå=íÜÉ=dóêçÅçãé~ëë

a^kdbo iáÑÉ=Ç~åÖÉê=íÜêçìÖÜ=ÉäÉÅíêáÅ~ä=ëÜçÅâ
tÜÉå=íÜÉ=ÖóêçÅçãé~ëë=áë=ÉåÉêÖáòÉÇI=íÜÉ=ÖóêçëéÜÉêÉ=çéÉê~íáåÖ=îçäí~ÖÉ=
çÑ=NMM=s^`=]=PPT=eò=áë=éêÉëÉåí=çå=íÜÉ=ã~ëíÉê=m`_I=íÜÉ=ÖóêçëéÜÉêÉ=ëìéJ
éäó=äáåÉëI=~åÇ=~Åêçëë=íÜÉ=ÖóêçëéÜÉêÉ=Åçåí~ÅíëK=
tÜÉå=íÜÉ=^`=ã~áå=ëìééäó=áë=ëïáíÅÜÉÇ=çåI=Ü~ò~êÇçìë=äáÑÉ=îçäí~ÖÉë=~êÉ=
éêÉëÉåí=~í=íÜÉ=äáåÉ=ÑáäíÉê=~åÇ=íÜÉ=éçïÉê=íê~åëÑçêãÉêÛë=íÉêãáå~äëK
j~âÉ=ëìêÉ=íÜ~í=íÜÉ=ã~áå=~åÇ=Ä~Åâìé=éçïÉê=ëìééäáÉë=çÑ=íÜÉ=ÖóêçÅçãé~ëë=
~êÉ=~äï~óë=ëïáíÅÜÉÇ=çÑÑ=~åÇ=ë~ÑÉÖì~êÇÉÇ=~Ö~áåëí=~ÅÅáÇÉåí~ä=ëïáíÅÜáåÖJ
çå=ÄÉÑçêÉ=ìåÇÉêí~âáåÖ=~åó=êÉãçî~ä=çê=áåëí~ää~íáçå=éêçÅÉÇìêÉë=çÑ=íÜÉ=
ÖóêçëéÜÉêÉ=Åçåí~áåÉêK

`^rqflk Risk of damage/destruction after power-down


After power-down of the gyrocompass system, it may take up to
45 minutes for the gyroscopes to stop rotating and the gyrosphere is
therefore extremely sensible against any movement. Should the gyro-
sphere touch the wall of the container, the momentum of the rotating
gyroscopes will make it topple and damage the centre pin.
Avoid any movement of the gyrocompass system during power-down
time. Always be extremely careful in case the gyrosphere container must
be handled during power-down time.

`^rqflk Risk of damage


Carry the container with the gyrosphere by hand only and handle it with
extreme care. Always keep the container in an upright position. Avoid
any sudden or shock-like movements.

`^rqflk Risk of damage/destruction through transport / wrong storing


When the container is temporarily stored away with the gyrosphere
installed, pack it into its original transport box or another suitable outer
package.
Always make sure that:
- the container is stored in an upright position,
- the temperature at the storage location cannot fall below 0° C,
- the container is not moved, tilted or subjected to shock.

m~êíëI=ã~íÉêá~äë=~åÇ=íççäë=êÉèìáêÉÇ

• the container Mod. 10/3, complete with installed gyrosphere and


filled with supporting fluid, as described in “Preparing the Container
for first time Installation” on page 17 and in “Installing the Gyro-
sphere in the Container” on page 19.
• a 5 mm hex key
• a No. 2 Philips-head screwdriver

dóêçëéÜÉêÉ=fåëí~ää~íáçå m~ÖÉ=OP
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

mêçÅÉÇìêÉ

1. Control if the compasses main and backup power supplies are


switched off. Take all the necessary precautions to make sure that
the compasses main and backup power supplies remain switched
off during any removal and installation procedures.
2. Unscrew the 5 mm hex-head screws of the gyrocompass housing
door and take off the door from the housing
3. Place the door aside. If the door is put next to the housing, the
grounding strap and CDU cable may be left connected to the main
PCB.
4. Gently turn the bellows, until the largest of the three coupling seats
in the bayonet collar points towards the front of the housing. The
seat is marked by a green dot on the collar.

5. Place the gyrosphere container


into the gyrocompass housing
with the largest of the three cou-
pling tongues located directly
below the groove in the collar.
⇒ The respective tongue is marked
by a green dot on the container.

6. Put both hands around the container and lift it into the collar, so that
the coupling tongues slide into the corresponding grooves in the
bayonet.

7. While supporting the container


with both palms, put the thumbs
on the rim of the collar, pull down
on it and turn it to the right

8. Gently lower the container. The


coupling tongues engage into their
seats in the bayonet and the con-
tainer locks in place by its own
weight.

m~ÖÉ=OQ dóêçëéÜÉêÉ=fåëí~ää~íáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

9. Plug the gyrosphere supply and


pick-off connector into the J1
socket of the optical pick-off PCB 1.

10. Check that the gyrosphere container turns freely around the vertical.
11. Put the door in front of the housing, so that the keys can be oper-
ated. If the CDU cable has been disconnected during gyrosphere
installation, reconnect it.
12. The gyrocompass is now ready to be put into operation.
Leave the housing door open to observe the settling of the gyro-
sphere and proceed now with the power-up function test, see
“Power-up function test” on page 45 for details.

dóêçëéÜÉêÉ=fåëí~ää~íáçå m~ÖÉ=OR
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

m~ÖÉ=OS dóêçëéÜÉêÉ=fåëí~ää~íáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

Q dóêçëéÜÉêÉ=oÉãçî~ä

QKN oÉãçîáåÖ=íÜÉ=`çåí~áåÉê=Ñêçã=íÜÉ=dóêçÅçãé~ëë

a^kdbo iáÑÉ=Ç~åÖÉê=íÜêçìÖÜ=ÉäÉÅíêáÅ~ä=ëÜçÅâ
tÜÉå=íÜÉ=ÖóêçÅçãé~ëë=áë=ÉåÉêÖáòÉÇI=íÜÉ=ÖóêçëéÜÉêÉ=çéÉê~íáåÖ=îçäí~ÖÉ=
çÑ=NMM=s^`=]=PPT=eò=áë=éêÉëÉåí=çå=íÜÉ=ã~ëíÉê=m`_I=íÜÉ=ÖóêçëéÜÉêÉ=ëìéJ
éäó=äáåÉëI=~åÇ=~Åêçëë=íÜÉ=ÖóêçëéÜÉêÉ=Åçåí~ÅíëK=
tÜÉå=íÜÉ=^`=ã~áå=ëìééäó=áë=ëïáíÅÜÉÇ=çåI=Ü~ò~êÇçìë=äáÑÉ=îçäí~ÖÉë=~êÉ=
éêÉëÉåí=~í=íÜÉ=äáåÉ=ÑáäíÉê=~åÇ=íÜÉ=éçïÉê=íê~åëÑçêãÉêÛë=íÉêãáå~äëK
j~âÉ=ëìêÉ=íÜ~í=íÜÉ=ã~áå=~åÇ=Ä~Åâìé=éçïÉê=ëìééäáÉë=çÑ=íÜÉ=ÖóêçÅçãé~ëë=
~êÉ=~äï~óë=ëïáíÅÜÉÇ=çÑÑ=~åÇ=ë~ÑÉÖì~êÇÉÇ=~Ö~áåëí=~ÅÅáÇÉåí~ä=ëïáíÅÜáåÖJ
çå=ÄÉÑçêÉ=ìåÇÉêí~âáåÖ=~åó=êÉãçî~ä=çê=áåëí~ää~íáçå=éêçÅÉÇìêÉë=çÑ=íÜÉ=
ÖóêçëéÜÉêÉ=Åçåí~áåÉêK

`^rqflk Risk of data loss through shutdown of the compass / power-off condition
After a shutdown of the compasses main and backup power supplies it
cannot be guaranteed that all menu settings remain stored unchanged.
Always check whether the shaft correction angle and alignment error cor-
rection values are noted correctly in the setup tables, before switching-
off the power supplies, see “Setup and Configuration Tables” appended
in the NAVIGAT X MK1 Operation, Installation and Service Manual
056343.
Always make sure to separately note the shaft correction angle and align-
ment error correction values before switching-down the compass for
maintenance or repair purposes.

`^rqflk Risk of damage/destruction after power-down


After power-down of the gyrocompass system, it may take up to
45 minutes for the gyroscopes to stop rotating and the gyrosphere is
therefore extremely sensible against any movement. Should the gyro-
sphere touch the wall of the container, the momentum of the rotating
gyroscopes will make it topple and damage the centre pin.
Avoid any movement of the gyrocompass system during power-down
time. Always be extremely careful in case the gyrosphere container must
be handled during power-down time.

`^rqflk Risk of damage/destruction through transport/wrong storing


When the container with the gyrosphere installed is temporarily stored
away, pack it into its original transport box or another suitable outer
package.
Always make sure that:
- the container is stored in an upright position,
- the temperature at the storage location cannot fall below 0°C,
- the container is not moved, tilted or subjected to shock.

m~êíëI=ã~íÉêá~äë=~åÇ=íççäë=êÉèìáêÉÇ

• a 5 mm hex key
• a No. 2 Philips-head screwdriver

dóêçëéÜÉêÉ=oÉãçî~ä m~ÖÉ=OT
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

mêçÅÉÇìêÉ

1. Check and note the shaft encoder correction angle and alignment
error correction values. Double check whether the shaft encoder cor-
rection angle and alignment error correction values are correctly
noted in the setup tables.
2. Switch off the compasses main and backup power supplies and take
all the necessary precautions to make sure that the compasses main
and backup power supplies remain switched off during any removal
and installation procedures.
3. Unscrew the 5 mm hex-head screws of the gyrocompass housing
door and take off the door from the housing
4. Disconnect the grounding strap between door and housing. Place
the door aside. If the door is put next to the housing, the grounding
strap and CDU cable may be left connected to the main PCB.

5. Unplug the gyrosphere supply and


pick-off connector from the J1
socket of the optical pick-off PCB 1.

6. Turn the bellows, until the largest


of the three coupling seats in the
bayonet collar points towards the
front of the housing.
⇒ The seat is marked by a green dot
on the collar.

7. Put both hands around the con-


tainer and lift it up, so that the cou-
pling tongues disengage from
their seats in the bayonet.

8. While supporting the container


with both palms, put the thumbs
on the rim of the collar, pull down
on it and turn it to the left

m~ÖÉ=OU dóêçëéÜÉêÉ=oÉãçî~ä
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

9. Gently lower the container. The


coupling tongues slide down in
the grooves of the bayonet and the
container is released from the col-
lar.

10. Carefully take the container out of the housing and put it onto the
work surface.
11. Proceed now with the removal of the gyrosphere from the container,
see “Removing the Gyrosphere from the Container” on page 30 for
details.

dóêçëéÜÉêÉ=oÉãçî~ä m~ÖÉ=OV
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

QKO oÉãçîáåÖ=íÜÉ=dóêçëéÜÉêÉ=Ñêçã=íÜÉ=`çåí~áåÉê

`^rqflk Risk of damage/destruction when removing the gyrosphere container


from an installed gyrocompass after power-down
After power-down of the gyrocompass system, it may take up to
45 minutes for the gyroscopes to stop rotating and the gyrosphere is
therefore extremely sensible against any movement. Should the gyro-
sphere touch the wall of the container, the momentum of the rotating
gyroscopes will make it topple and damage the centre pin.
Avoid any movement of the gyrocompass system during power-down
time. Always be extremely careful in case the gyrosphere container must
be handled during power-down time.

`^rqflk Risk of damage to the gyrosphere through pollution


Any pollution of the gyrosphere will negatively impact the functionality
and service life period of the Gyrosphere/3 gyrocompass system.
Never pollute the gyrosphere during installation or removal procedures.
Always maintain a clear workplace and handle the gyrosphere with
clean, thoroughly washed hands only.

kçíÉ After power-down of the gyrocompass system, wait at least 45 minutes


for the gyroscopes to stop rotating before opening the container or drain-
ing off the supporting fluid.

j~íÉêá~äë=~åÇ=íççäë=êÉèìáêÉÇ

• the installation and replacement parts kit, stock no. 22638


• a 4 mm hex key

mêçÅÉÇìêÉ

1. Place the container onto the work


surface.
2. Take the plastic bowl from the
installation and replacement parts
kit and place it under the drain
plug of the gyrosphere container.

3. Unscrew and remove one of the fill


plugs.

m~ÖÉ=PM dóêçëéÜÉêÉ=oÉãçî~ä
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

4. Unscrew the drain plug and drain


off some supporting fluid into the
bowl until the fluid level reaches
the top of the humps in the bowl
(approx. 0.5 l of fluid).

5. Screw in and re-tighten the drain


plug
6. Dispose off the used supporting
fluid.

kçíÉ The supporting fluid is not poisonous and is not harmful to the environ-
ment. Used fluid may be poured overboard or flushed down a drain.

7. Place the plastic bowl under the drain plug again, unscrew the plug
and drain off the remaining fluid.
8. Screw in and re-tighten the drain plug and dispose of the used sup-
porting fluid.

9. Unscrew the 4 mm hex-head


screws attaching the two halves of
the gyrosphere container.
10. Take off the top section of the
gyrosphere container and place it
on the work surface.
11. Carefully lift the gyrosphere out of
the gyrosphere container and let
the supporting fluid from the
recess run into the bottom section
of the container.

12. Carefully return the sphere to the


upright position and place it onto
the plastic bowl.
13. Dispose of the remaining support-
ing fluid from the bottom section
of the container.

14. Proceed with the maintenance of the gyrosphere, see “Gyrosphere


Maintenance” on page 33.
15. Proceed then with the maintenance of the gyrosphere container, see
“Gyrosphere Container Maintenance” on page 35.

dóêçëéÜÉêÉ=oÉãçî~ä m~ÖÉ=PN
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

m~ÖÉ=PO dóêçëéÜÉêÉ=oÉãçî~ä
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

R dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë

`^rqflk Risk of mercury contamination


The gyrosphere type 3 and the gyrosphere container mod. 10/3 are
designed for mercury free operation. Any usage of mercury will severely
contaminate the gyrosphere type 3 / gyrosphere container mod. 10/3.
Never use mercury with the gyrosphere type 3 and the gyrosphere con-
tainer mod. 10/3.
In case of usage of mercury by mistake, the contaminated equipment
must not be used and all safety instructions of the Sperry Marine Mer-
cury Handling Procedure 026150-0000-000 must be followed accordingly.

`^rqflk Risk of damage to the gyrosphere through pollution


Any pollution of the gyrosphere will negatively impact the functionality
and service life period of the Gyrosphere/3 gyrocompass system.
Never pollute the gyrosphere during installation or removal procedures.
Always maintain a clear workplace and handle the gyrosphere with
clean, thoroughly washed hands only.

`^rqflk Risk of damage through improper cleaning liquids


Normal water can be polluted and contain germs and algae, which can
easily reproduce in the supporting fluid warming up in operation, caus-
ing pollution and improper working conditions to the gyrosphere.
Never use normal water or other improper cleaning liquids for cleaning
the gyrosphere or the container.

kçíÉ Residual supporting fluid may be used as an alternative cleaning liquid


R
when still clear and in good condition.

RKN dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ

m~êíë=~åÇ=íççäë=êÉèìáêÉÇ

• the installation and replacement parts kit, stock no. 22638, which
was used during installation of the gyrosphere
• a lint-free cloth or cleaning tissue
• soapy water or a washing solution containing a mild detergent

mêçÅÉÇìêÉ

1. Place the gyrosphere carefully onto the plastic bowl from the instal-
lation kit.
2. Control the recess of the gyrosphere carefully for any possible signs
of mercury contamination by mistake.
⇒ In case no sign of mercury contamination can be detected, follow the
procedure as described.

dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë m~ÖÉ=PP
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

kçíÉ In case of any mercury contamination, the procedure must be stopped.


The gyrosphere must not be used and all safety instructions of the Sperry
Marine Mercury Handling Procedure 026150-0000-000 must be followed
accordingly.

3. Carefully wash the gyrosphere with soapy water or a washing solu-


tion containing a mild detergent.
4. Thoroughly dry off the gyrosphere with a lint-free cloth or cleaning
tissue. Dip with the cloth down into the recess to make sure that the
bottom of the recess is absolutely clean and dry.
5. Inspect the gyrosphere carefully for any outer damage, as buckles,
brush marks, corrosion, discolouration or delamination of the lac-
quer surface.
– In case of minor outer damage, the gyrosphere may become
cleaned and reworked to get operable again.
– In case of severe outer damage, the gyrosphere is to be regarded
as none operable anymore.
6. Inspect the top and bottom contact surfaces carefully for any signs
of corrosion or discolouration.
– If necessary, use the stainless steel wool pad from the installa-
tion and replacement parts kit to clean small corroded spots.
– In case of severe corrosion or discolouration, the gyrosphere is
to be regarded as none operable anymore.
The following figures show examples of gyrosphere corrosion:

Comprehensive brush marks on


the gyrosphere shell, caused by
broken centering pin / imbalance
of gyrosphere.
⇒ Gyrosphere is to be exchanged.

Severe corrosion of the gyro-


sphere bottom contact and partly
of the gyrosphere shell.
⇒ Gyrosphere is to be exchanged.

7. If the gyrosphere is free from any damage and found in fully opera-
ble condition, place the gyrosphere carefully back onto the plastic
bowl from the installation kit.
⇒ Proceed with the maintenance of the gyrosphere container

8. If the gyrosphere is found in none operable condition, it is to be


taken out of service.
⇒ Proceed with “Preparing the Gyrosphere for Transport” on page 43.

m~ÖÉ=PQ dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

RKO dóêçëéÜÉêÉ=`çåí~áåÉê=j~áåíÉå~åÅÉ=

m~êíëI=ã~íÉêá~äë=~åÇ=íççäë=êÉèìáêÉÇ

• a lint-free cloth or cleaning tissue


• fresh water for rinsing the container
• if sticky residue of supporting fluid has formed:
– soapy water or a washing solution containing a mild detergent
• if signs of corrosion of the contact surfaces are found:
– the installation and replacement parts kit, stock no. 22638
• if the centering pin is to be replaced:
– a new centering pin, stock no. 22575
– a calibrated torque wrench, for low level torque values around
1 Nm
• if the drain plug / drain plug joint is to be replaced:
– a new type drain plug, complete with joint, stock no. 25764
or:
– an old type drain plug stock no. 21871
– an old type drain plug joint, stock no. 25571
• for the electrical continuity test:
– a multi meter true RMS

sáëì~ä=fåëéÉÅíáçå=mêçÅÉÇìêÉ

1. Thoroughly rinse the top and bottom sections of the container with
fresh water.
2. Inspect the housing joints and bearing joints carefully for any
mechanical damage, e.g. notches or small cracks.
⇒ In case of any mechanical damage found, the joints are to be
exchanged.

3. Remove the drain plug, check type of the drain plug and inspect the
condition of the drain plug joint.
cáÖìêÉ=RJNW
fåëéÉÅíáçå=çÑ=
Çê~áå=éäìÖ=íóéÉ

Old type drain plug with red New type drain plug with black
joint, onetime usage only. joint, re-usable if undamaged.

dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë m~ÖÉ=PR
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

⇒ In case of any damage found on the drain plug or the joint, the
defective part is to be exchanged.

⇒ In case of old type drain plug, the red joint is for one time usage and
always to be replaced by default.

kçíÉ Sperry Marine recommends to replace the old type drain plug completely
against the new type with the black re-usable joint.

⇒ In case of new type drain plug and damaged black joint, the black
joint is to be replaced.

4. Inspect the insides of the container sections for sticky residue of the
supporting fluid. If necessary, use soapy water or a washing solution
containing a mild detergent to wash the sections.
5. Inspect the insides of the container sections for any signs of
mechanical damage, e.g. abrasion.
⇒ In case of any mechanical damage found on the container outside or
inside, the container is to be exchanged.

The following figures show examples for mechanical damage of the


container:

Right PCB fixture broken caused


by physical damage to the con-
tainer housing.
⇒ Container is to be exchanged.

Severe burning of the container


top contact, caused by lack of sup-
porting fluid and resulting over
temperature.
⇒ Container is to be exchanged.

6. Inspect the viewing windows of the optical pick-off for any damages,
as cracks, scratches, pollution or cloudiness.

kçíÉ In case of any mechanical damage found on a viewing window of the


optical pick-offs, a repair is not possible and the complete container is to
be exchanged.

m~ÖÉ=PS dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

The following figures show examples of viewing window damages


of the optical pick-off as a guidance for evaluation:

Viewing window with deep cracks,


partly broken.
⇒ Container is to be exchanged

Viewing window with parallel ver-


tical scratches.
⇒ Container is to be exchanged.

7. Inspect the top and bottom contact surfaces for signs of corrosion.
If necessary, use the stainless steel wool pad from the installation
and replacement parts kit to clean corroded spots.
The following figure shows an example for bottom contact corrosion
of the container:

Discolouration of the container


inside top contact caused by lack
of supporting fluid and resulting
over temperature.
⇒ Top contact is to be cleaned.

Corrosion and discolouration of


the container inside bottom con-
tact caused by lack of supporting
fluid and resulting over tempera-
ture.
⇒ Bottom contact / container is to be
exchanged.

8. Thoroughly wipe dry the container sections with a lint free cloth or
cleaning tissue.
9. Sight check the fitting accuracy of the centering pin whether it is cor-
rectly fitted in the middle of the container with correctly fitted center
pin screw.
10. Loosen the center pin screw and remove the centering pin.

dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë m~ÖÉ=PT
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

11. Inspect the centering pin for signs of any damage. Replace the pin if
it is bent or the tip is damaged in any way.
The following figure shows an example for centering pin damage:

Centering pin tip broken caused by


ongoing operation with lack of
supporting fluid and resulting over
temperature.
⇒ Centering pin is to be exchanged.

⇒ In case of a five-year maintenance, the centering pin is to be


replaced by default.

12. Insert the centering pin and push it back as far as possible. Attach it
by screwing in the center pin screw again.

kçíÉ In case the center pin screw does not grip, the centering pin is not pushed
in far enough.

13. Control the torque of the center


pin screw with a calibrated torque
wrench whether a torque value of
1 Nm is applied.
⇒ Correct the torque if necessary.

14. Control additionally, if the container top contact can be turned by


hand from the container housing inside.
⇒ When the torque of the center pin screw is correctly applied, the con-
tainer top contact cannot be turned by hand from the container
housing inside.

15. If the container is found in fully operable condition:


⇒ Proceed with the “Electrical Inspection Procedure” on page 39.

16. If the container is found in none operable condition, it is to be taken


out of service and exchanged.

m~ÖÉ=PU dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

bäÉÅíêáÅ~ä=fåëéÉÅíáçå=mêçÅÉÇìêÉ

kçíÉ The electrical inspection procedure of the container implies electrical


continuity tests of the optical pick-offs PCB 1 / PCB 2 and the container
top and bottom contacts only.
Functional tests of the optical pick-offs PCB 1 / PCB 2 are not serviceable
in the field and not part of these service instructions.

kçíÉ Sperry Marine recommends to have the optical pick-off PCBs exchanged
by default every other 18-month maintenance interval (= after 36-month).

bäÉÅíêáÅ~ä=`çåíáåìáíó=qÉëíë

1. With a multi meter true RMS apply electrical continuity tests of the
following optical pick-offs PCB 1 / PCB 2 and container connections:
– J1/pin 2 to top contact (inner side of the container)
– J1/pin 4 to bottom contact (inner side of the container)
– Flat cable pins 1 – 4 of J3/PCB 1 to pins 1 – 4 of J2/PCB 2.

kçíÉ For details regarding the wiring of the gyrosphere container mod 10/3
see also wiring diagram 4914-0115-04 in the appendix.

q~ÄäÉ=RJOW
`çåíáåìáíó=qÉëí=`çååÉÅíáçå lh kçí=lh
`çåíáåìáíó=íÉëí=î~äìÉë=
J1/2 → top contact (container) 0,0 – 0,5=Ω > 0,5=Ω
J1/4 → bottom contact (container) 0,0 – 0,5=Ω > 0,5=Ω
PCB 1 J3/1 – 4 → PCB 2 J2/1 – 4 0,0 – 0,5=Ω > 0,5=Ω

2. In case the tested Ω values exceed the mandatory values, control the
top and bottom contacts of the container for correct torque and seat
and repeat the electrical continuity tests.
3. In case the tested Ω values still exceed the mandatory values, the
container or the optical pick-off PCBs are to be considered as defec-
tive and must be exchanged.
⇒ For exchanging the optical pick-off PCBs, see “Replacement of the
Optical pick-off PCBs” on page 40 for details.

4. In case the tested Ω values meet the mandatory values:


⇒ Proceed either with re-installing the gyrosphere into the container as
described in “Installing the Gyrosphere in the Container” on
page 19, or with installing a new gyrosphere, as described in “First
time Installation” on page 15.

⇒ Proceed then with the installation of the container into the gyrocom-
pass, see “Installing the Container in the Gyrocompass” on page 23
for details.

dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë m~ÖÉ=PV
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

oÉéä~ÅÉãÉåí=çÑ=íÜÉ=léíáÅ~ä=éáÅâJçÑÑ=m`_ë

`^rqflk Risk of damage to the optical pick-offs flat cable connection


Any damage to the flat cable connecting the J3 connector of optical pick-
off PCB 1 with the J2 connector of optical pick-off PCB 2 will cause mal-
function to the gyrosphere.
A damaged flat cable can not be ordered as separate spare part.
Always handle the flat cable with care and be careful not to damage the
flat cable during replacement of the optical pick-offs.

kçíÉ Sperry Marine recommends to have the optical pick-off PCBs exchanged
by default every second 18-month maintenance interval (= 36-month).

kçíÉ The optical pick-off PCBs must always become exchanged in pairs to
ensure proper working conditions.
Do not mix used and new optical pick-off PCBs on one container.

m~êíëI=ã~íÉêá~äë=~åÇ=íççäë=êÉèìáêÉÇ

• a No. 2 Philips-head screwdriver

oÉãçî~ä=mêçÅÉÇìêÉ

1. Unscrew the three screws and


remove screws and carton wash-
ers securing the optical pick-off
PCB 1 from the holding fixture of
the container.

2. Remove the PCB 1 with the cables


from the holding fixtures of the
container.

m~ÖÉ=QM dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

3. Bend the retaining plate of the G2


plug connector away and unplug
the G2 connector from the G2
socket.

4. Bend the retaining plate of the G3


plug connector (flat cable) away
and unplug the G3 connector from
the G3 socket.

5. Remove the PCB 1 from the con-


tainer

6. Repeat steps 1 – 3 and 5 accordingly for the removal of the optical


pick-off PCB 2.

fåëí~ää=mêçÅÉÇìêÉ

1. Plug the G3 connector (flat cable)


into the G3 socket of the new opti-
cal pick-off PCB 1.

dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë m~ÖÉ=QN
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

2. Plug the G2 connector into the G2


socket of the new optical pick-off
PCB 1.

3. Insert the top contact cable into


the cut-out of the container top
section.

4. Insert the flat cable behind the


holding pin on the container top
section.

5. Apply the new optical pick-off


PCB 1 to the holding fixture of the
container and secure it with the
three screws and carton washers.

6. Repeat steps 1 to 5 accordingly for the installation of the optical pick-


off PCB 2.
7. Proceed now with the electrical continuity test of the container, see
“Electrical Continuity Tests” on page 39 for details.

m~ÖÉ=QO dóêçëéÜÉêÉ=j~áåíÉå~åÅÉ=mêçÅÉÇìêÉë
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

S mêÉé~êáåÖ=oÉJfåëí~ää~íáçå=L=qê~åëéçêí

SKN mêÉé~êáåÖ=íÜÉ=dóêçëéÜÉêÉ=Ñçê=oÉJfåëí~ää~íáçå

m~êíë=~åÇ=íççäë=êÉèìáêÉÇ

• the installation and replacement parts kit, stock no. 22638, which
was used during installation of the gyrosphere
• a lint-free cloth or cleaning tissue
• soapy water or a washing solution containing a mild detergent

1. Place the gyrosphere onto the plastic bowl from the installation kit.
2. Carefully wash the gyrosphere with soapy water or a washing solu-
tion containing a mild detergent.
3. Thoroughly dry off the gyrosphere with a lint-free cloth or cleaning
tissue. Dip with the cloth down into the recess to make sure, that the
bottom of the recess is absolutely clean and dry.
4. Inspect the top and bottom contacts for signs of corrosion. In case
any signs of corrosion are found, proceed with the maintenance of
the gyrosphere, see “Gyrosphere Maintenance” on page 33.
5. Proceed now with the installation of the gyrosphere in the container,
see “Installing the Gyrosphere in the Container” on page 19

SKO mêÉé~êáåÖ=íÜÉ=dóêçëéÜÉêÉ=Ñçê=qê~åëéçêí

m~êíë=~åÇ=íççäë=êÉèìáêÉÇ

• the installation and replacement parts kit, stock no. 22638, which
was used during installation of the gyrosphere
• a lint-free cloth or cleaning tissue
• soapy water or a washing solution containing a mild detergent
• a lockable plastic bag (provided with the replacement gyrosphere)
• the Gyrosphere Service Report, 04914-0126-05

mêçÅÉÇìêÉ

1. Place the gyrosphere onto the plastic bowl from the installation kit.
2. Carefully wash the gyrosphere with soapy water or a washing solu-
tion containing a mild detergent.
3. Thoroughly dry off the gyrosphere with a lint-free cloth or cleaning
tissue. Dip with the cloth down into the recess to make sure, that the
bottom of the recess is absolutely clean and dry.

mêÉé~êáåÖ=oÉJfåëí~ää~íáçå=L=qê~åëéçêí m~ÖÉ=QP
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

4. Put the gyrosphere in the plastic bag provided with the replacement
gyrosphere and seal the bag.
5. Carefully put the gyrosphere back in its transport box, fix the gyro-
sphere with the top carton element.
6. Fill in the Gyrosphere Service Report (GSR), 4914-0126-05, found in
the appendix of this service procedure, and pack into the transport
box with the returned Gyrosphere
7. Then return the original transport box to Sperry Marine.

kçíÉ Make sure to include the completed Gyrosphere Service Report (GSR),
04914-0126-05, when returning a defective gyrosphere to Sperry Marine.
When the service report is not returned, no warranty exchange of the
gyrosphere is possible.

SKP mêÉé~êáåÖ=íÜÉ=`çåí~áåÉê=Ñçê=oÉJfåëí~ää~íáçå

m~êíë=~åÇ=íççäë=êÉèìáêÉÇ

• a lint-free cloth or cleaning tissue


• fresh water for rinsing the container
• if sticky residue of supporting fluid has formed:
soapy water or a washing solution containing a mild detergent

mêçÅÉÇìêÉ

1. Remove the screws and washers from the top section of the con-
tainer and put them aside.
2. Thoroughly rinse the top and bottom sections of the container with
fresh water.
3. Inspect the insides of the container sections for sticky residue of the
supporting fluid. If necessary, use soapy water or a washing solution
containing a mild detergent to wash the sections.
4. Inspect the top and bottom contact surfaces for signs of corrosion. In
case any signs of corrosion are found, proceed with the mainte-
nance of the container, see “Gyrosphere Container Maintenance” on
page 35.
5. Thoroughly wipe dry the container sections with a lint free cloth or
cleaning tissue.
6. Inspect the centering pin for any signs of damage. In case any signs
of damage are found, proceed with the maintenance of the con-
tainer, see “Gyrosphere Container Maintenance” on page 35.
7. Place the cleaned and dried sections of the container onto the work
surface and proceed now with the installation of the gyrosphere into
the container, see “Installing the Gyrosphere in the Container” on
page 19.

m~ÖÉ=QQ mêÉé~êáåÖ=oÉJfåëí~ää~íáçå=L=qê~åëéçêí
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

T cáêëíJíáãÉ=léÉê~íáçå

TKN mçïÉêJìé=ÑìåÅíáçå=íÉëí

a^kdbo iáÑÉ=Ç~åÖÉê=íÜêçìÖÜ=ÉäÉÅíêáÅ~ä=ëÜçÅâ
tÜÉå=íÜÉ=ÖóêçÅçãé~ëë=áë=ÉåÉêÖáòÉÇI=íÜÉ=ÖóêçëéÜÉêÉ=çéÉê~íáåÖ=îçäí~ÖÉ=
çÑ=NMM=s^`=]=PPT=eò=áë=éêÉëÉåí=çå=íÜÉ=ã~ëíÉê=m`_I=íÜÉ=ÖóêçëéÜÉêÉ=ëìéJ
éäó=äáåÉë=~åÇ=~Åêçëë=íÜÉ=ÖóêçëéÜÉêÉ=Åçåí~ÅíëK
tÜÉå=íÜÉ=^`=ã~áå=ëìééäó=áë=ëïáíÅÜÉÇ=çåI=Ü~ò~êÇçìë=äáÑÉ=îçäí~ÖÉë=~êÉ=
éêÉëÉåí=~í=íÜÉ=äáåÉ=ÑáäíÉê=~åÇ=íÜÉ=éçïÉê=íê~åëÑçêãÉêÛë=íÉêãáå~äëK
_É=ÉñíêÉãÉäó=Å~êÉÑìä=ïÜÉå=çéÉê~íáåÖ=íÜÉ=ÖóêçÅçãé~ëë=ïÜáäÉ=íÜÉ=ÜçìëJ
áåÖ=áë=çéÉåK=kÉîÉê=íçìÅÜ=íÜÉ=ã~ëíÉê=m`_I=íÜÉ=ÅçååÉÅíáåÖ=Å~ÄäÉë=íç=íÜÉ=
ÖóêçëéÜÉêÉ=Åçåí~áåÉê=çê=~åó=çíÜÉê=ÅçåÇìÅíáîÉ=ÅçãéçåÉåíë=çå=íÜÉ=ÅçåJ
í~áåÉê=çê=áå=íÜÉ=ÖóêçÅçãé~ëë=ÜçìëáåÖK

To verify the correct operation of an installed or re-installed gyrosphere,


the settling behaviour of the gyrocompass is to be observed, with the
front door of the gyrocompass housing opened.

kçíÉ For a present operating voltage of 100 VAC on the master PCB, 105 VAC
true RMS are necessary.
The setting of true RMS can be adjusted via the potentiometer on the
master PCB. For details see figure 7-4 on page 49 respectively figure 7-5
on page 49.

dóêçëéÜÉêÉ=`ìêêÉåí=mêÉäáãáå~êáÉë

The value of the gyrosphere current is decreasing continuously after


power-up and is a key indicator for a successful gyrosphere settling at a
given point of time during the power-up function test.

The gyrosphere current value in the Service Setup 2 (code 610), indi-
cated at the CDU, is a reading value only and may deviate from the true
operating gyrosphere current value (measured true RMS), for details
see the Service Setup 2 menu in the operating manuals of the respective
NAVIGAT X MK1 /MK2 system.

The true operating value of the gyrosphere current can only be meas-
ured directly at the:

• 1 Ω gyro current test resistor (R103) of the MK1 master PCB for the
NAVIGAT X MK1, Digital Gyrocompass System.
• 1 Ω gyro current test resistor (R54) of the MK2 master PCB for the
NAVIGAT X MK2, Digital Gyrocompass System.

kçíÉ The AC-voltage in mV across the test resistors (R103/R54) equals the
gyrosphere current in mA.

Figure 7-1 on page 46 shows the location of the 1 Ω gyro current test
resistor (R103) on the master PCB of the NAVIGAT X MK1, Digital Gyro-
compass System.

cáêëíJíáãÉ=léÉê~íáçå m~ÖÉ=QR
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

Figure 7-2 shows the location of the 1 Ω gyro current test resistor (R54)
on the master PCB of the NAVIGAT X MK2, Digital Gyrocompass Sys-
tem.

cáÖìêÉ=TJNW
dóêç=ÅìêêÉåí=íÉëí=êÉëáëíçê=
EoNMPF=äçÅ~íÉÇ=çå=íÜÉ=
jhN=ã~ëíÉê=m`_

The 1 Ω gyro current test resis-


R103
tor (R103) is located at the left
side of the MK1 master PCB
close beneath the J4 connector
and TB8.

cáÖìêÉ=TJOW
dóêç=ÅìêêÉåí=íÉëí=êÉëáëíçê=
EoRQF=äçÅ~íÉÇ=çå=íÜÉ=
jhO=ã~ëíÉê=m`_

TB 4

J3
R 54

The 1 Ω gyro current test resis-


tor (R54) is located at the left
TB 1 side of the MK2 master PCB
close to the J3 connector and
TB4.

m~êíëI=ã~íÉêá~äë=~åÇ=íççäë=êÉèìáêÉÇ

• Trimmer adjustment tool


• Multi meter true RMS

mêçÅÉÇìêÉ

1. Power up the gyrocompass system.

m~ÖÉ=QS cáêëíJíáãÉ=léÉê~íáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

A startup screen is shown and a system


SPERRY MARINE
test sequence is executed.
NAVIGAT X MK 1

kçíÉ For this procedure, the illustrating screens and pictures are taken from
the NAVIGAT X MK1, Digital Gyrocompass System. Examples apply
accordingly for the NAVIGAT X MK2, Digital Gyrocompass System.

A startup screen is shown and a system


SPERRY MARINE
test sequence is executed.
NAVIGAT X MK 1

When the system test has been passed,


>F1 GYRO 1 271.2°
F2 GYRO 2 271.4°
the gyrocompass enters normal opera-
F3 MAGN.C. 270.9° tional mode. The display shows the
DIFF G1/G2 5°ü heading data from the available gyro-
compasses and the heading difference
alarm threshold.

– In case of a first-time installation where the basic configuration


has not been carried out yet, alarms will be given at this point.
Alarms caused by missing input data or an incomplete system
configuration may be safely acknowledged to continue with the
power-up function test.

`^rqflk Risk of defective gyrosphere caused by “GYRO FAILURE”


Should a “GYRO FAILURE” alarm occur during power-up, the gyrocom-
pass is not working properly.
De-energize the system and visually check the connections to the gyro-
sphere, the follow-up step motor and the shaft encoder.
If the failure reoccurs when the gyrocompass is powered-up again, the
installation has not been carried out correctly or the gyrosphere is defec-
tive and must be replaced.

2. Observe the settling of the gyrosphere:


– The gyro motors will create a spinning noise which slowly but
constantly rises in pitch until the rotors reach their final speed.
– The follow-up system will turn the container quickly around the
gyrosphere until the optical pick-off “locks” onto the motion of
the gyrosphere.
From then on, the container will engage in a slow oscillatory
motion around the vertical, following the motion of the gyro-
sphere.
– The amplitude and speed of this motion will steadily decrease
until the gyrosphere finally settles.
3. During the settling phase, periodically call up the gyrosphere data
sub-menu from the Service Setup 2 (code 610), to observe the gyro-
sphere current:

cáêëíJíáãÉ=léÉê~íáçå m~ÖÉ=QT
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

Directly after power-up, the gyro-


GYROSHPERE DATA
TEMPERATURE 42 °C
sphere current should not exceed
PH BRIDGE 10 mV 550 mA. The current will gradually
GYRO CURR 432 mA fall while the gyrosphere settles.

kçíÉ 20 minutes after power-up a considerable fall of the gyrosphere current


should have occurred.

4. Check 20 minutes after power-up whether a considerable fall of the


gyrosphere current has occurred.

Within around 45 minutes after


GYROSHPERE DATA
TEMPERATURE 42 °C
power-up, the gyrosphere current
PH BRIDGE 10 mV should have dropped below 320 mA.
GYRO CURR 234 mA

5. Check if after around 45 minutes after power-up whether the gyro-


sphere current has dropped below 320 mA.

kçíÉ The true operating value of the gyrosphere current can only be measured
(true RMS) at the 1 Ω gyro current test resistors (R103/R54) on the master
PCB of the NAVIGAT X MK1/MK2 system, locations are shown in
figure 7-1 on page 46 and figure 7-2 on page 46.

6. If after around 45 minutes after the power-up, a gyrosphere current


above 320 mA is still displayed in the gyrosphere data sub-menu,
the value must be reconfirmed:
– Measure the gyrosphere current directly at the 1 Ω gyro current
test resistor (R103/R54) on the master PCB of the NAVIGAT X
MK1/MK2 system, the locations of the test resistors (R103/R54)
are shown in figure 7-1 on page 46 and figure 7-2 on page 46.

kçíÉ The AC-voltage in mV across the test resistor (R103/R54) equals the gyro-
sphere current in mA.

7. In case the reconfirmed value for the gyrosphere current, directly


measured (true RMS) at the 1 Ω gyro current test resistor (R103/R54)
on the master PCB of the NAVIGAT X MK1/MK2 system, is in con-
trast under 320 mA, the gyrosphere current gain factor settings in
the Technical Pages (code 140) need to become checked and
adjusted:
– Follow the instructions in ”CORRECTION VALUES” of the ‘Fac-
tory Settings Menu (Technical Pages)´ in the operating manuals
of the respective NAVIGAT X MK1 /MK2 system, to match both
gyrosphere current values.
8. In case the reconfirmed value for the gyrosphere current, directly
measured (true RMS) at the 1 Ω gyro current test resistor (R103/R54)
on the master PCB, is as well above 320 mA, the VAC true RMS value
needs to become adjusted:

m~ÖÉ=QU cáêëíJíáãÉ=léÉê~íáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

kçíÉ For a present operating voltage of 100 VAC on the master PCB, 105 VAC
true RMS are necessary.

cáÖìêÉ=TJPW
– Measure the VAC true RMS
jÉ~ëìêÉãÉåí=çÑ=s^`=
at pins 1 and 2 (wires white
íêìÉ=ojp=~í=gQ
and brown) of the J4 con-
nector on the NAVIGAT X
MK1 master PCB, or
measure the VAC true RMS
for the NAVIGAT X MK2 sys-
tem accordingly at the pins 1
and 2 (wires white and
brown) of the J3 connector
on the NAVIGAT X MK2
master PCB.
For the location of the J3 con-
nector see figure 7-5 for details.

cáÖìêÉ=TJQW
9. Adjust the potentiometer (R36)
^ÇàìëíãÉåí=çÑ=íêìÉ=ojp=
on the NAVIGAT X MK1 master
~í=éçíÉåíáçãÉíÉê=oPS=çå=
PCB with a trimmer adjustment
íÜÉ=jhN=ã~ëíÉê=m`_=
tool to set 105 VAC true RMS.
⇒ Be careful not to damage the
potentiometer (R36).

cáÖìêÉ=TJRW
Or adjust the potentiometer (R9)
içÅ~íáçå=çÑ=íÜÉ=
on the NAVIGAT X MK2 master
mçíÉåíáçãÉíÉê=oV=çå=
PCB accordingly with a trimmer
íÜÉ=jhO=ã~ëíÉê=m`_=
adjustment tool to set 105 VAC
true RMS.

R9
⇒ Be careful not to damage the
potentiometer (R9).

The location of the potentiome-


ter (R9) is shown in adjacent
figure 7-5.

J3

cáêëíJíáãÉ=léÉê~íáçå m~ÖÉ=QV
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

kçíÉ A regular screwdriver is not recommended for the adjustment of the


potentiometer (R36/R9) as these are sensible components.

cáÖìêÉ=TJSW
10. Measure again the VAC true
jÉ~ëìêÉãÉåí=çÑ=s^`=
RMS at the pins 1 and 2 (wires
íêìÉ=ojp=~í=gQ
white and brown) of the J4 con-
nector on the NAVIGAT X MK1
master PCB.
Or measure again the VAC true
RMS for the NAVIGAT X MK2
system accordingly at the pins 1
and 2 (wires white and brown)
of the J3 connector on the
NAVIGAT X MK2 master PCB.
11. Repeat steps 8 – 10 if necessary
until 105 VAC true RMS are set.

`^rqflk Risk of defective gyrosphere


The gyrosphere may not be in operable working condition, if after a time
period of around 45 minutes after power-up the gyrosphere current has
not dropped below 320 mA.
If a visual inspection reveals no obvious cause of malfunction, the power
up cycle of the gyrosphere must be completely repeated.
If after a time period of around 45 minutes after the second power-up
cycle the gyrosphere current has still not dropped below 320 m, the gyro-
sphere may not be in operable working condition.
Contact the Sperry Marine Service for advice.

⇒ If the current is still above 320 mA, the gyrosphere may not be in
operable working condition.

12. Proceed with a visual inspection of the gyrosphere, to search any


obvious cause for malfunction, see “Gyrosphere Maintenance” on
page 33 for details.
13. If a visual inspection reveals no obvious cause for malfunction,
repeat the complete power-up procedure and check again if after
around 45 minutes after the second power-up cycle the gyrosphere
current has dropped below 320 mA.
⇒ If after around 45 minutes after the second power-up cycle the cur-
rent is still above 320 mA, and no other obvious cause of malfunc-
tion is found, the gyrosphere may not be in operable working
condition:
– Contact the Sperry Marine Service for advice.
⇒ If after around 45 minutes after the second power-up cycle the gyro-
sphere current has dropped below 320 mA, the gyrosphere is inop-
erable working condition:
– Proceed with the power-up procedure.
14. Note the exact gyrosphere current value in the setup tables.
15. After a settling time of at least 4 hours, verify that the gyrocompass
has settled to the correct heading.

m~ÖÉ=RM cáêëíJíáãÉ=léÉê~íáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

kçíÉ The 4 hours settling time for the alignment is only mandatory in case of
a first time installation of the Gyrosphere/3.

kçíÉ To verify the gyrocompass’ heading, the actual true heading of the vessel
should be known with an accuracy of ± 0.1°.

– Check whether the setting of the shaft encoder correction value


in the Service Setup 1 of manual 056343 matches with the value
indicated on the baseplate.
– In case of a first time installation, check that the heading shows
the correct value approximately, taking into account any existing
misalignment of the gyrocompass. Then, set the alignment error
correction value in the Service Setup 1 as required, see “Align-
ment Error Correction” of manual 056343 for details. After the
alignment error correction value has been set, the gyrocompass
is to display the vessel's true heading with an accuracy of ± 0.5°.
– In case of maintenance or replacement of the gyrosphere, the
displayed heading should now already be accurate within ± 1.0°.
If necessary, adjust the stored alignment error correction value,
so that the gyrocompass displays the vessel's true heading with
an accuracy of ± 0.5°, see “Storing the magnetic heading calibra-
tion table” of manual 056343 for details.
16. In case of a regular maintenance, or if a defective gyrosphere has
been replaced, a special service setup menu must now be called up
to reset the gyrosphere operation time counter.

kçíÉ The access code for the setup menu to reset the gyrosphere operation
time counter is disclosed to authorized service personnel only and is not
described in this service procedures.

cáêëíJíáãÉ=léÉê~íáçå m~ÖÉ=RN
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

m~ÖÉ=RO cáêëíJíáãÉ=léÉê~íáçå
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

U pé~êÉ=m~êíë

UKN fääìëíê~íÉÇ=m~êíë=iáëí=EfmiF=lîÉêîáÉï
q~ÄäÉ=UJNW
pé~êÉ=m~êí k~ãÉ píçÅâ=kçK
fmi=çÑ=ëóëíÉã=ëé~êÉ=é~êíë
Container, Mod. 10/3 022561-0000-000

Gyrosphere, type 3 074829-0000-000


(mercury free)

Centerpin, Mod. 10/3 022575-0000-000

Supporting fluid, 049050-0000-000


1 l btl.
(Mod. 10 = 1 btl.;
Mod. 7 = 3 btl.)

Gyrosphere installa- 022638-0000-000


tion kit, suitcase* (Mod. 10/3)

kçíÉ * The parts list of the gyrosphere installation kit is appended as docu-
ment 004914-0126-000, 004914-0126-001 and 004914-0126-004 in the
appendix of this manual.

pé~êÉ=m~êíë m~ÖÉ=RP
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

m~ÖÉ=RQ pé~êÉ=m~êíë
dóêçëéÜÉêÉLP MMRMMMJMNORJMMNL`

^ééÉåÇáñ

^ dóêçëéÜÉêÉ=pÉêîáÅÉ=oÉéçêí
The following Gyrosphere Service Report (blank form) is to be used
when returning a defective gyrosphere to Sperry Marine:

aÉëáÖå~íáçå aê~ïáåÖ=kçK
Gyrosphere Service Report: 4914-0126-05
Gyrocompass Installation Kit Mod. 10/3 4914-0126-04
022638-0000-000

kçíÉ Make sure to include the gyrosphere service report, 04914-0126-05, when
returning a defective gyrosphere to Sperry Marine.
When the service report is not returned, no warranty exchange of the
gyrosphere is possible.

_ aê~ïáåÖë
The following drawings are part of the appendix of this manual:

aÉëáÖå~íáçå aê~ïáåÖ=kçK
Dimensional drawing: 4991-0112-03
Gyro Container Mod. 10/3
Dimensional drawing: 5000-0112-01
Gyrosphere Type 3
Wiring diagram: 4914-0115-04
Gyrosphere Container Mod. 10/3

kçíÉ All appended drawings are revision-controlled separately at Sperry


Marine. In case of doubt, verify the current revision status of the draw-
ings with Sperry Marine. This manual’s revision status does not automat-
ically change in time in case the revision of an appended drawing
changes.

m~ÖÉ=RR
MMRMMMJMNORJMMNL` dóêçëéÜÉêÉLP

m~ÖÉ=RS
004914-0126-005/D; 07 Nov 2013; Page 1 of 1
dóêçëéÜÉêÉ=pÉêîáÅÉ=oÉéçêí
cáää=áå=íÜáë=ëÉêîáÅÉ=êÉéçêí=ÅçãéäÉíÉäó=~åÇ=êÉíìêå=áí=íçÖÉíÜÉê=ïáíÜ=íÜÉ=ÇÉÑÉÅíáîÉ=ÖóêçëéÜÉêÉ
EëÉêîáÅÉ=êÉéçêí=áåëáÇÉ=çÑ=ÖóêçëéÜÉêÉ=íê~åëéçêí=ÄçñF=íç=íÜÉ=ÑçääçïáåÖ=~ÇÇêÉëë=çåäóW
Northrop Grumman Sperry Marine
Haringsbuisweg 29
3133 KP Vlaardingen / Holland
Tel.: +31 (0) 10-44 51 653
fÑ=íÜÉ=ëÉêîáÅÉ=êÉéçêí=áë=åçí=êÉíìêåÉÇI=åç=ï~êê~åíó=ÉñÅÜ~åÖÉ=çÑ=íÜÉ=ÖóêçëéÜÉêÉ=áë=éçëëáÄäÉ>

sÉëëÉäÛë=k~ãÉW _________________ lïåÉêW _________________

eìää=kçKW _________________ pÜáéó~êÇW _________________

=dóêçëéÜÉêÉ
S/N ________________ exchanged against: S/N ________________
(defective) (replacement)

=oÉéä~ÅÉãÉåí
êÉÅÉáîÉÇ=éÉêW Sales Order No.: ____________________ Date: _______________

=êÉÅÉáîÉÇ=éÉêW Service Order No.: ____________________ Date: _______________

fí=áë=ã~åÇ~íçêó=íç=Ñáää=áå=~í=äÉ~ëí=íÜÉ=p~äÉë=lêÇÉê=kçK=çê=íÜÉ=pÉêîáÅÉ=lêÇÉê=kçK>

=oÉ~ëçå=Ñçê o gyrosphere current too high (_______________ mA)


oÉéä~ÅÉãÉåí
o heading error (_______________ ° off true hdg.)
o fluids dirty
o bottom contact corroded
o centering pin burnt
o excessive noise
o other (please specify):__________________________________________
=dóêçëéÜÉêÉ =^ãÄáÉåí=íÉãéÉê~íìêÉW o above 40 °C
çéÉê~íáçå~ä=ëáåÅÉW __________________ o below 40 °C
=`çãé~ëë=póëíÉã NAVIGAT NAVIGAT
qóéÉ o II, III, IV, V o VII, VIII, IX
X, XII, SR180 X MK 1, SR 180 MK 1, X MK 2
o Mod. 10 o Mod. 10
o Mod. 7 o Mod. 7
o Mod. 10/2
o Mod. 7/2
Service Station / Name: Date / Signature:
_____________________ ________________________________

Northrop Grumman Sperry Marine B.V.


Woltmanstr. 19, D-20097 Hamburg, Germany
Tel.: +49-40-299 00-0, Fax: +49-40-299 00-146, E-mail: service.eu@sperry.ngc.com
Parts List

Page 1
of 1
Gyrocompass Installation Kit Mod. 10/3
022638-0000-000

STOCK No. 004914-0126-004


Gyrosphere Installation Kit 022638-0000-000, comprising:

DRAWING No. 4914-0126-04


Part No. Qty. Description Ref.

047976-0 0 0 0-0 0 0 1 Case 1

049050-0 0 0 0-0 0 0 1 Supporting Fluid, 1l 2

033347-0 0 0 0-0 0 0 1 Plastic Bowl 3

046547-0 0 0 0-0 0 0 1 Funnel 4

025550-0 0 0 0-0 0 0 1 Stainless Steel Wool Pad 5


not
004914-0 1 2 6-0 0 4 1 Parts List shown

NAME
21.03.2011 Fi.
DATE
ECO-No.
983079
1

REV.
A1
2

5 4

Northrop Grumman Sperry Marine B.V.


Woltmanstr. 19, D-20097 Hamburg, Germany
Tel.: +49-40-299 00-0, Fax: +49-40-299 00-298, E-mail: service.de@sperry.ngc.com
Sperry Marine Service: www.sperrymarine.com/offices

Northrop Grumman Sperry Marine B.V. (Representative Office)


Woltmanstr. 19 • D-20097 • Hamburg, Germany
Tel.: +49-40-299 00-0 • Fax: +49-40-299 00-146 • E-mail: service.eu@sperry.ngc.com