Sie sind auf Seite 1von 1

TYPE "A"

MIN
2000

EXISTING SIDEWALK

2400
N
MI
BUS

1700
N
STOP

MI
2% SLOPE

EXISTING CURB
16000

TYPE "B"

2400
N
BUS

MI
STOP 2% SLOPE

EXISTING CURB
16000

A
TYPE "C"
CONCRETE ADDITION
MIN
FOR ACCESSIBILITY
3000

MIN
1000
BUS

1700
N
MI
STOP EXISTING SIDEWALK
2% SLOPE

EXISTING CURB

1.7 m MIN
EXPANSION JOINT

100 um THICK POLYETHYLENE SLOPE2%-4%


CURB OR CURB AND GUTTER
VAPOUR BARRIER. (OR EQUIVALENT)
t

150 mm GRANULAR A BASE

150 CONCRETE
SIDEWALK

SECTION A-A
NOTES:

1. FOR CONCRETE SIDEWALK ABUTTING CURB OR CURB


AND GUTTER REFER TO T-600.05-1 AND T-600.11-1.

2. SIDEWALK THICKNESS 130 mm EXCEPT ACROSS COMMERCIAL, INDUSTRIAL


AND HIGH DENSITY RESIDENTIAL DRIVEWAY WHERE THICKNESS SHALL BE 180 mm.

3. t = THICKNESS OF SIDEWALK (BUS STOP LANDING).

4. JOINTS SHALL BE ACCORDING TO T-310.010-1.

All dimensions are in millimetres unless otherwise shown.

ENGINEERING & CONSTRUCTION SERVICES STANDARD DRAWING


REV 2 NOV 2014

BUS STOP LANDING FOR STANDARD T-310.010-8


AND ARTICULATED BUSES
NTS SHEET 1