Sie sind auf Seite 1von 24

BILL OF QUANTITIES

Reinforced Concrete Struc

Item No. Code no.


M100

M113.1
M113.2
M113.3
M113.4
Reinforced Concrete Structure:

Description
ROOFING WORK
Metal Roof Structure
Rate to include connecting plates, bolts, nuts, all welding, and other fastening system
[Dimension of mild steel universal column] mild steel universal column. [Grade ?? To BS 4360] as rafter as shown in Draw
[ ] mild steel square hollow section, [ ] as top chord member as shown in Drawing No. ()
[] C-channel purlins. [] as shown in Drawing No. ()
[] thick cold formed galvanised mild steel
Unit Qty Rate Amount (RM)

kg
kg
kg
Item No Code No.
Rate for in situ concrete designed mix shall be deemed to include placing and compac

I111.1
I111.2
I112

I121
I122.1
I122.2
I122.3
I122.4

I132.1
I132.2
I132.3
I132.4
I133
I134
I135
I136

I142.1
I142.1

I152.1
I152.2
I152.3
I152.4
I153
I100 IN SITU CONCRETE DESGIN MIX

Description Unit Qty.


Rate for in situ concrete designed mix shall be deemed to include placing and compaction of concrete

Grade: C37 Concrete


Mass concrete blinding, [50] mm thick to [footing] m2
Mass concrete blinding, [50] mm thick to [raft foundation] m2
Mass concrete benching to sumps. m3
Grade: C20
Mass concrete blinding, [75] mm thick to [clear water tank] m2
Mass concrete benching to sumps. m3
Mass concrete benching to trenches m3
Mass concrete surround to pipes m3
Mass concrete screed to fall for roof m3
Grade: C25
Reinforced concrete to base of valve chamber m3
Reinforced concrete to footing of shop house m3
Reinforced concrete to ground slab to shop house m3
Reinforced concrete to beams to shop house
Reinforced concrete columns of shop house m3
Reinforced concrete to walls of valve chambers m3
Reinforced concrete to suspended slabs at first floor m3
Other concrete forms, reinforced concrete to steps and staircase m3
Grade: C30
Reinforced concrete base to trenches m3
Other concrete forms, reinforced concrete to steps and staircase m3
Grade: C35
Reinforced concrete base to elevated water tank m3
Reinforced concrete to footings of SEB sub-station m3
Reinforced concrete pile caps m3
Reinforced concrete gound slabs m3
Other concrete forms m3
Rate Amount (RM)
of concrete
Item No. Code No.
F100

F111.1
F111.2

F300

F312

F500

F520
Description Unit Qty
EXCAVATION
Stripping
Topsoil of average depth of 150 mm and disposed to the contractor's dumpsite as approv m2 29400
Topsoil of average depth of 150 mm and stockpile for re-use as top soil for turfing m2

FILLING
The following items for filling shall include compaction, and additional filling necessitated by settlement or penetration i
General
Imported material from Contractor's own source with grading limits as per Specification c m3 88200

LANDSCAPING
Items for landscaping shall be deemed to include digging, planting media, bedding, stalking, protection, watering, weedi
Trees of the tropical species with minimum girth of 200 mm and 3 m tall nr 35

trench 0.5
Rate (RM/unit) Amount (RM)

1.5 44100
4.69

lement or penetration into underlying material as applicable

12.67 1117494

ection, watering, weeding, required fertilising, and replacement of dead item until the vegtation is established

TOTAL 1161594
Item No. Code No.
Items for demolition and site clearance shall be deemed to include dis
E100

1 E100.1
Descritption
Items for demolition and site clearance shall be deemed to include disposal of the materials arising
GENERAL CLEARANCE
Above Ground
General clearance to primary forest. Rate to include the removal of trees and stumps, undergrowth, shrubs, root
Summary of Class E carried to Grand Summary
Unit Qty. Rate Amount (RM)
the materials arising

ha 2.94 2229.88 6555.8472


ItemNo, Code No.

G100
G110
G120
G130
Description Unit

PLANT AND EQUIPMENT


Provision of all necessary plant and equipment, transportation to the site, handling, assem sum
Moving and handling all necessary plant and equipment within the site and from location tsum
Temporary staging sum
Qty. Rate Amount (RM)
Item No. Code No.

H100
H110
H120

H200

H251.1
H251.2
H252.1
H254

H500
H510.1
H520
Description

PLANT AND EQUIPMENT


Provision of all necessary piling plant and equipment, transportation to the site, handling, assemblin
Moving and handling of all piling plant and equipment within the site and from location to location a

PILES
Item for piling work shall be deemed to include piling records and disposal of excavated and surplus materials

Precast Reinforced Concrete Piles


250 mm G45 square precast reinforced concrete piles with a working load of 2310 kN
Supply initial piles with rock shoes of 12 m length
Supply extension piles of 2m length
Depth driven
Jointing with butt weld all around as shown in Drawing No.

PILE TEST
Initial static load test on 900 mm diameter bored pile up to two times working load of 16,000kN
Pile integity test (sonic echo test) on 250 mm diameter precast concrete pile
Unit Qty. Rate Amount (RM)

sum
sum

and surplus materials

nr 308
nr 308
m 40
m 0.6

nr
nr
Item No. Code No.
J100

J111.1

J400

J411.1
J411.2
J412
J413

J421
J422.1
J422.2
Description Unit Qty.
BRICKWORK
Item for brickworks shall be deemed to include joint reinforcement, movement joints, fixing ties, bonds to existing work

[??? mm] thick common brickwork laid in stretcher bond, jointed in [ratio??] cement morta
m2

MISCELLANEOUS WORK
Surface Features
Brick on edge coping m
Bullnosed copings m
Decorative cornices as shown in Drawing No. () m
Brickwork plinths as shown in Drawing No. () m
Ancillaries
Damp proof courses; width [115 mm] to BS 743 type D m
Built-in 150 mm DN uPVC drainage pipes nr
Built-in 50 mmDN uPVC cable ducts nr
Rate Amount (RM)

, bonds to existing work and fixing clamps


Unit No Code No.
M100

M113.1
M113.2
M113.3
M114.1
M114.2

M121.1
M122
M123

M131
M132

M141
M142
Description
ROOFING WORK
Metal Roof Structure
Rate to include connecting plates, bolts, nuts, all welding and other fastening system
[457 mm X 191 mm X 98 kg/m] mild steel universal column. [Grade 43A to BS 4360] as shown in Drawing No.[]
[75 mm X 75 X 4 mm thick X 8.60 kg/m] mild steel square hollow section, [Grade 43A toBS 4360] as top chord member
[150 X 75 X 4 mm thick 18.60 kg/m] C-channel purlins. [Grade 43A to BS 4360] as shown in Drawing No. []
Mild steel, Grade 43A to BS 4360 roof truss sytem and components to be designed by contractor. Rate to include connec
Galvanised mild steel roof truss system and components using cold-rolled steel to be designed by contractor. Rate to in
Roof Covering
Rate to include preparing surfaces, forming joints, overlaps, mitres, angles, fillets, built-up edges, and laying to falls or ca
[6 mm thick polycarbonate flat sheet] laid at [?? Degrees] as shown in Drawing No.[]
[0.48 mm base steel thickness colourbond corrugated roofing sheet] laid at [?? Degree to the horizontal] as shown In
[Interlocking concrete roofing tiles] laid to [?? Degrees to the horizontal as shown in Drawing No []
Underlay
Rate to include preparing surfaces, forming joints, overlaps, mitres, angles, fillets, built-up edges, and laying to falls or ca
[One layer of 50 mm X 50 mm X 22 SWG galvanised wire mesh fixed with tying wire]
[One layer of double sided aluminium foil sisalation]
Insulation
Rate to include preparing surfaces, forming joints, overlaps, mitres, angles, fillets, built-up edges, and laying to falls or ca
[50 mm thick rock wool sheet size 1200 mm X 600 mm
[50 mm thick fiberglass insulation]
Unit Qty. Rate Amount (RM)

kg
kg
kg
m2
m2

ing to falls or cambers, cutting, notching, bending, and bedding


m2
m2
m2

ing to falls or cambers, cutting, notching, bending, and bedding


m2
m2

ing to falls or cambers, cutting, notching, bending, and bedding


m2
m2

Das könnte Ihnen auch gefallen