REQUIRNMENT QUANTITY SOURCE

PARKING 4103 @ 50SQM PER VEHICLE BRIEF, PGNO.8


TOTAL PLOT AREA 55390.75 SQM BRIEF, PGNO.17
NET SITE AREA 54612.14 SQM BRIEF, PGNO.17
PERMISIBLE FAR 3.25 BRIEF, PGNO.8
G.C. ALLOWED 45% BRIEF, PGNO.18
BUILT-UP REQUIRED 274376.64 SQM BRIEF, PGNO.18
BUILIDING FLOORS 2B + G+ 9 UF + Terrace floor BRIEF, PGNO.18
3B + G + 9 UF +Terrace floor BRIEF, PGNO.18
3B + G + 9 UF +Terrace floor BRIEF, PGNO.18
3B + Stilt + 8 UF + Terrace floor BRIEF, PGNO.18

MAX HEIGHT 42.675 M BRIEF, PGNO.10


TOTAL NO. OF USERS 15602( DETAIL IN BRIEF) BRIEF, PGNO.25

PLINTH MIN. 450MM BBL 2017 KARNATAKA PGNO.32


CLEAR HEIGHT ROOM MIN. 2.4 M BBL 2017 KARNATAKA PGNO.32
CLEAR HEIGHT TOI MIN 2.1M BBL 2017 KARNATAKA PGNO.32

BASEMENT
CLEAR HEIGHT 2.4M - 4.5M BBL 2017 KARNATAKA PGNO.34
ROOF 1.2M ABOVE GROUND LVL BBL 2017 KARNATAKA PGNO.34
The access to the basement shall be separate from the main and alternative staircase BBL 2017 KARNATAKA PGNO.34
The first basement (fullyproviding and exit
below ground from
level) canhigher floor
be used or services/parking/other BBL 2017 KARNATAKA PGNO.75
permissible services. Lower basements, if provided, shall exclusively be used for car
parking only.

STARICASE
WIDTH 1.5 MIN BBL 2017 KARNATAKA PGNO.36
TREAD 300 MAX BBL 2017 KARNATAKA PGNO.36
RISER 150 MAX BBL 2017 KARNATAKA PGNO.36
BOUNDRY HEIGHT 2.4M MAX BBL 2017 KARNATAKA PGNO.34
EXIT FROM A POINT 30M MAX BBL 2017 KARNATAKA PGNO.37
WIDTH OF CORRIDOR 1.5 M MIN BBL 2017 KARNATAKA PGNO.38

SANITATION REQ.
WATER CLOSET One for every 25 persons or part there of every 15 BBL 2017 KARNATAKA PGNO.42
person
For female personnel 1 for every 15 persons or part BBL 2017 KARNATAKA PGNO.42
thereof exceeding 10.
WASH BASIN One for every 25 persons or part thereof BBL 2017 KARNATAKA PGNO.46
URINALS 4 for 71-100 persons BBL 2017 KARNATAKA PGNO.46
for over 200 persons add @ 2.5%
DRINKING WATER One for every100 persons with a minimum of one on BBL 2017 KARNATAKA PGNO.46
each floor
DRINKING WATER One for every100 persons with a minimum of one on
each floor
WATER CLOSET ENCLOSURES 900x1200 BBL 2017 KARNATAKA PGNO.46

RAIN WATER HARVESTING SYS BBL 2017 KARNATAKA PGNO.67

SERVICE DUCTS Service duct shall be enclosed by walls and door, if any, BBL 2017 KARNATAKA PGNO.76
of 2 hours fire rating. If ducts are larger than 10 Sq.m

ELECTRICAL SERVICES The electric distribution cables/wiring shall be laid in a BBL 2017 KARNATAKA PGNO.76
separate duct
Water mains, telephone wires, inter-com lines, gas pipes BBL 2017 KARNATAKA PGNO.76
or any other service lines shall not be laid in ducts for
electric cables.

AIR - CONDITIONING Escape routes like staircase, common corridors, lift BBL 2017 KARNATAKA PGNO.77
lobbies;
Area more etc. should
than 750 not
Sq.mbemuse as return
on individual airshould
floor passage.
be BBL 2017 KARNATAKA PGNO.77
ELECTRIC - SUBSTATION segregated by a firewall and automatic fire dampers
Clear independent approach to the sub-station from for
outside isolationshall
the building should be provided.
bebe
made available
The sub-station must not located belowround the
the 1st
clock.
basement
The sub-station area shall have a clear height of 15 feet
(4.5 m.) below beams. Further
Suitable arrangement for pump the Substation
house, water area will
storage
have level above the rest of basement level
tanks with main electrical pump and a by 2 feet.
diesel-operated pump shall be made if no such
arrangement is provided in the building. In case the
water pumping facilities are existing in the building for
sprinkler system, the same should however
be utilized for high velocity water spray system.
Alternatively, automatic CO2 total flooding system
shall be provided with manual controls outside the
electric sub-station.

Electric control panels shall be segregated.