Sie sind auf Seite 1von 40

Access Control

SiPass® integrated
MP2.65 SP2

Product Release Notes

Siemens Schweiz AG
SSP ES
Liefermöglichkeiten und technische Änderungen vorbehalten.
Data and design subject to change without notice. / Supply subject to availability.
© 2014 Copyright by Siemens Schweiz AG

Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte
an und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder
außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.

We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights
and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our
prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
Contents
1 Introduction..........................................................................................5
1.1 SiPass integrated MP2.65 and Interoperability .......................................5
1.2 What this document covers ....................................................................5
1.3 Ordering ................................................................................................5

2 Important Release Information (Pre-Requisites) ................................6


2.1 Security Recommendations ...................................................................6
2.1.1 Installing SiPass integrated / ACCs / Dialups on a Public Domain ..........6
2.1.2 Reducing Security Risks with Anti-Virus Software ..................................6
2.2 Windows Patches and Hot Fixes ............................................................7

3 New Features for SiPass integrated MP2.65.......................................8


3.1 Enhanced Access Assignment ...............................................................8
3.2 Venue Management...............................................................................9
3.3 Cardholder User Interface Enhancement ...............................................9
3.4 SiPass integrated Web Client.................................................................9
3.5 Enhanced DESFire Encoding............................................................... 10
3.6 Improved HR-API Functionality ............................................................ 10
3.7 Complete Support for AR40S-MF and AR10S-MF Readers .................. 10
3.8 Upgrading from SiPass integrated MP2.65 to higher versions .............. 10

4 SiPass integrated Installation Compatibility ....................................12


4.1 SiPass integrated Server ..................................................................... 12
4.2 SiPass integrated Client ....................................................................... 12
4.3 Microsoft SQL Server........................................................................... 13
4.4 .NET Framework.................................................................................. 13
4.5 Web Client Browser Compatibility ........................................................ 13
4.6 Web Client Smart Device Compatibility ................................................ 14
4.7 System Compatibility ........................................................................... 14
4.7.1 Firmware ............................................................................................. 14
4.7.2 Hardware ............................................................................................. 14
4.7.2.1 Controllers ........................................................................................... 14
4.7.2.2 Door Control ........................................................................................15
4.7.2.3 I/O ....................................................................................................... 15
4.8 API / HLI Compatibility ......................................................................... 15
4.8.1 HR-API Interface.................................................................................. 15
4.8.2 Management/Enterprise Station API .................................................... 15
4.8.3 OPC A&E Server Interface................................................................... 15
4.9 Digital Video Recorder (DVR) System Compatibility ............................. 16
4.9.1 Premium DVR Integration .................................................................... 16
4.9.1.1 VSS-SDK Compatibility........................................................................ 16
rd
4.9.2 3 Party DVR Integration (Requires DVR-API Connection License) ..... 17
4.10 CCTV System Compatibility ................................................................. 17
4.10.1 Premium CCTV Integration .................................................................. 17
4.10.2 3rd Party CCTV Integration (Requires Connection License) .................17
4.11 Directly-connected IP Camera Compatibility......................................... 18
4.12 Intrusion Panel Compatibility ................................................................ 18
4.13 Card Printer Compatibility .................................................................... 18
4.14 MiFare Classic Card Encoding (while printing) ..................................... 19
4.15 Enrollment Reader Compatibility .......................................................... 19
4.15.1 RS-232 Enrollment Readers ................................................................19
4.15.2 RS-485 Enrollment Readers ................................................................19
4.15.3 USB Enrollment Readers ..................................................................... 19
4.16 Card Format Compatibility ................................................................... 20
4.16.1 Reader Connection Types ................................................................... 20
3

Siemens Schweiz AG 12.2014


4.16.2 Siemens Proprietary Card Formats ...................................................... 20
4.16.3 Proximity Formats................................................................................ 20
4.16.4 Smart Card Formats ............................................................................ 20
4.16.5 Bar Code Formats ............................................................................... 20
4.16.6 Magnetic Stripe Formats ...................................................................... 20
4.17 Card Reader Compatibility ................................................................... 21
4.17.1 Siemens AR Range ............................................................................. 21
4.17.2 Readers Supporting the DESFire EV1 Card Technology ...................... 21
4.17.3 Siemens EM Proximity Reader Range ................................................. 21
4.17.4 Siemens Miscellaneous ....................................................................... 22
4.17.5 HID Proximity and MIFARE Classic...................................................... 22
4.18 Card Technology Compatibility ............................................................ 23
4.19 Morpho 4G V-Station Reader Compatibility .......................................... 23
4.20 Granta MK3 Reader PIN Pad Type Compatibility ................................. 24
4.21 Signature Capture Tablet Compatibility ................................................ 25
4.22 Messaging System Compatibility.......................................................... 25
4.23 Server Redundancy ............................................................................. 26
4.24 Offline Door System............................................................................. 26
4.25 Virtualization ........................................................................................ 26
4.26 For more information… ........................................................................ 26

5 Enhancements and Quality Improvements for SiPass integrated


MP2.65 SP2 ........................................................................................ 27
5.1 Enhancements..................................................................................... 27
5.2 Fixed Issues ........................................................................................ 29

6 Keyword index ................................................................................... 41

Siemens Schweiz AG 12.2014


Introduction

1 Introduction
SiPass® integrated is an advanced access control system. Its superior range of se-
curity features ensures that it is an ideal access control solution for any application
regardless of size or complexity.
SiPass integrated MP2.65 is your interoperable security solution. It combines ad-
vanced access control with easy yet powerful connectivity to Video, Intrusion (Sin-
tony 400 series/SPC), Building comfort (APOGEE, DESIGO CC), OPC A&E com-
pliant applications, Building Management Stations, Offline door access systems
(SALTO), and finally Fire and Danger Management (MM8000).
SiPass integrated -- Opening doors to a secure environment.

1.1 SiPass integrated MP2.65 and Interoperability


This market package, for SiPass integrated MP2.65, introduces a number of
enhancements and quality improvements to the Access Control and Security
system.

1.2 What this document covers


This document details the changes that have been made to SiPass integrated and
the important information that users need to be aware of when ordering, installing
and troubleshooting.

1.3 Ordering
To order the SiPass integrated software, please use the order forms provided and
the part numbers specified on these forms.

Siemens Schweiz AG 12.2014


Important Release Information (Pre-Requisites)

2 Important Release Information (Pre-Requisites)


Before installing SiPass integrated, refer to the SiPass integrated Installation Guide
for important information about installing the software. The SiPass integrated In-
stallation Guide contains all the necessary procedures to install and upgrade the
software and all other associated hardware and software components. This guide
can be found on the SiPass integrated DVD-ROM.

2.1 Security Recommendations


This section details important security recommendations regarding the installation
of SiPass integrated on public domains. It also deals with the important issue of
protecting your software system from virus infections.

2.1.1 Installing SiPass integrated / ACCs / Dialups on a Public Domain

Users please note that installing SiPass integrated on a public domain presents
vulnerabilities (e.g., being infected by PC viruses) like any application running on a
Windows environment.
If SiPass integrated or ACCs etc. are to be installed on a public domain, it is rec-
ommended that a dedicated network (like a minimal VLAN) be used for optimal se-
curity. Telnet and SSH on the controllers should be disabled after installation. Fur-
ther, installation of the server and the client as dedicated applications on PCs is
advisable.
SiPass integrated users are also advised to lockdown USB ports on the PCs where
SiPass integrated has been installed. Further, it is recommended that client PCs
for non-administrator operators should be locked down.

2.1.2 Reducing Security Risks with Anti-Virus Software

It is recommended that all SiPass integrated operators install and run an Anti-Virus
or Virus Scan application to protect your computer from viruses, and other security
threats that can compromise the performance of the system.
SiPass integrated has been tested with the TREND MICRO Office Scan software.
As there are numerous brands of anti-virus software available in the market, it is
recommended that you first investigate the source of software before downloading
and installing it. It is advisable that you choose a virus scanner that best meets the
needs of your particular software environment. It is also important that you test
your anti-virus application with SiPass integrated before going live to ensure that
the anti-virus application does not impact the performance of your security man-
agement.
Please contact vendors of the chosen anti-virus software for instructions and up-
dates.

Siemens Schweiz AG 12.2014


Important Release Information (Pre-Requisites)

2.2 Windows Patches and Hot Fixes


It is expected that SiPass integrated will continue to operate as normal if you
automatically update your PC with any updates or patches provided by Microsoft.
However, some exceptional changes made by Microsoft to their operating system
may cause unexpected results. In these instances please report your problem to
your local support representative and the issue will be investigated as soon as
possible.

Siemens Schweiz AG 12.2014


New Features for SiPass integrated MP2.65

3 New Features for SiPass integrated MP2.65


With the introduction of several new and innovative features in this latest market
package, SiPass integrated MP2.65 builds itself into a more robust and powerful
system, that can meet all your access control requirements.
Read more here about the following latest features and enhancements now avail-
able in SiPass integrated in this latest market package:
- Enhanced Access Assignment
- Venue Management
- Cardholder User Interface Enhancement
- SiPass integrated Web Client
- Enhanced DESFire Encoding
- HR-API Functionality Improvements
- Complete Support for AR40S-MF and AR10S-MF Readers

3.1 Enhanced Access Assignment


The advanced intelligence of this new SiPass integrated market package makes it
possible for operators to assign Multiple Access Rights to cardholders, workgroups
or venues, without limitations on the number of access rights per cardholder.
SiPass integrated MP2.65 allows these access rights to be assigned as combinati-
on of Private Access, Workgroup Access and Venue Access rights for each
cardholder. These access rights can be assigned permanently, or temporarily (with
a specific start and end date & time).
In this enhanced market package, any modification to the access rights of a
workgroup will be immediately applied to all cardholders of the workgroup. Further,
cardholders with multiple workgroups assigned to them, will inherit all access rights
from their workgroups.
Note that if a database is restored from MP2.60 or earlier, any existing workgroup
access rights will be disabled by default in MP2.65. This is due to the new behavi-
our of workgroup access rights in MP2.65. In MP2.60 and earlier, workgroup ac-
cess rights were transferred to cardholders after workgroup assignment, after
which the cardholder access rights could be further customised. In MP2.65, di-
sabling existing workgroup access rights by default will avoid giving unintended ac-
cess to existing cardholders, since workgroup access rights are now inherited by
the cardholder. Workgroup access rights can be enabled in the workgroup dialog if
the operator is confident with the access configuration of the workgroup and card-
holders involved.
Expired access can be removed automatically from cardholder and workgroup by
using Host Based Event Tasks.

Conversion of older access concepts after upgrade to SiPass int. MP2.65


– Temporary Access Groups: On upgrade, each existing Temporary Access
Group will be converted to a Venue and a Venue Booking, with the same tempo-
rary access group name.
8

Siemens Schweiz AG 12.2014


New Features for SiPass integrated MP2.65

Any cardholders that were assigned to the Temporary Access Group will now be
assigned to its converted Venue Booking.
– Personalized Access Groups: On upgrade, any existing Personalized Access
Groups for a cardholder will be converted as Private access privileges.
They will be visible (with the same Personalized Access Group name) under the
Private access privileges tree, on the Definition tab of the Cardholder dialog.
– Offline Access Groups: On upgrade, any existing Offline Access Groups for a
cardholder will be converted as Private access privileges.
They will be visible (with the same Offline Access Group name) under the Pri-
vate access privileges tree, on the Definition tab of the Cardholder dialog.
More details on Access Assignment can be found in the SiPass integrated MP2.65
User Guide.

3.2 Venue Management


This innovative feature is an excellent addition for sites with Meeting Rooms, Con-
ference Halls, or similar shared locations used by several groups of people. SiPass
integrated MP2.65 makes it possible to configure such shared locations as Venues
with a collection of access components like access points, levels, groups and intru-
sion area points, etc.
The prime advantage of this feature is that operators can book these Venues for
one-off or scheduled bookings using the Venue Booking feature in SiPass integra-
ted Client and Web client.
Operators can also give configure access rights to cardholders as venue booking
Organizers or Participants. Participant access rights can be configured privately to
individual cardholders, and also to entire workgroups.
The Venue Booking User Interface provides an excellent visual overview of all the
venue bookings across all venues, and also across calendar periods.
Note: The Temporary Access Group will be converted to Venues and Venue Boo-
kings when upgraded to MP2.65.

3.3 Cardholder User Interface Enhancement


This market package provides enhanced features for the cardholder user interface,
wherein the entire Cardholder/Visitor dialog is customizable.
Compared to previous versions where operators could only add customized pages
to the Cardholder/Visitor dialog; this market package features a completely custo-
mizable Cardholder/Visitor dialog, which contains a default pre-defined layout.
Operators can customize the layout, and add/modify desired controls to any page,
minimizing the need for opening multiple tabs in the dialog.
Different Operator Groups also have the flexibility of creating layouts specific to
their group.

3.4 SiPass integrated Web Client


SiPass integrated MP2.65 successfully launches the remote management capabili-
ty of its access control system, through its well-integrated Web Client.

Siemens Schweiz AG 12.2014


New Features for SiPass integrated MP2.65

Utilizing the same login credentials as the SiPass integrated client, the Web Client
makes it possible to seamlessly manage Cardholdes, Venues and Venue Boo-
kings, Access Levels, and Access Groups.
Linking of the web interface to the client layouts allow the Web Client to use
customized layouts created in the SiPass integrated client, that can then be as-
signed to specific operator groups.
Please refer the SiPass integrated Installation Guide for details supported Brow-
sers, Operating Systems and Smart Devices.

3.5 Enhanced DESFire Encoding


The DesFire Smart Card Encoding feature is enhanced in SiPass integrated
MP2.65 to include the ability to distinguish between the Master Key and Applica-
tion Key of the card.
This allows Cardholder field mapping in SiPass integrated to Applications and Files
of the DESFire card in the Profile Configuration dialog.
It allows operators to set the Application Key and the Application Master Key, while
supporting the DES, 3DES or AES Encryption Algorithm

3.6 Improved HR-API Functionality


In MP2.65, the HR-API is enhanced to be able to fully manage cardholders / visitor,
Access Assignment, Access Level, Access Group, Venue and Venue Booking,
Workgroups.
These improvements provide operators with advanced flexibility for Access As-
signment in SiPass integrated via 3rd party applications. The HR-API also automa-
tically notifies the 3rd party application about changes in SiPass integrated, related
to Cardholders, Access Assignment or Venues/Venue Bookings, which allows ap-
plications to automatically synchronize with SiPass integrated.

3.7 Complete Support for AR40S-MF and AR10S-MF Readers


SiPass integrated MP2.65 fully supports the AR40S-MF and AR10S-MF readers.
New reader firmware can be downloaded to the readers using the SiPass inte-
grated software.
This new market package also supports encrypted communication between the
controller and these readers using secure OSDP. This is currently supported for
the DRIs.

3.8 Upgrading from SiPass integrated MP2.65 to higher versions


SiPass integrated MP2.65 can upgrade to higher versions without uninstalling the
current SiPass version on the system, while completely retaining the current data-
base.
For detailed information, please refer Section 8.2 of the Installation Guide on the
CD.

10

Siemens Schweiz AG 12.2014


New Features for SiPass integrated MP2.65

For SiPass version Upgrade, and License Change:


Performing a SiPass version Upgrade, and License Update/Change cannot be
done at the same time.
1. You must first upgrade to the new SiPass version required.
2. Next, run the installer file of the new SiPass version to update/change the li-
cense.

11

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4 SiPass integrated Installation Compatibility


The following tables outline the components that have been tested with this version
of SiPass integrated.

4.1 SiPass integrated Server


Please note that the following tables relate to the English version of the Windows
Operating Systems outlined.

Windows 8.1 Windows Windows Windows 7 Windows 2003


(32-bit & 64-bit) Server 2012 R2 Server 2008 R2 (Professional, Server (SP2)*
(64-bit) (SP1) (32-bit only)
Enterprise) SP1
(64-bit)
(32-bit & 64-bit)

ü ü ü ü ü

*Some additional configuration settings are required to ensure that the specified versions of Windows
operating systems operate correctly with SiPass integrated. Please refer Appendix 10.1 contained
within the SiPass integrated MP2.65 SP2 Installation Guide for further information.

4.2 SiPass integrated Client


Please note that the following tables relate to the English version of the Windows
Operating Systems outlined.

Windows 8.1 Windows Windows Windows 7 Windows 2003


(32-bit & 64-bit) Server 2012 R2 Server 2008 R2 (Professional, Server (SP2)*
(64-bit) (SP1) (32-bit only)
Enterprise) SP1
(64-bit)
(32-bit & 64-bit)

ü ü ü ü ü

NOTE
Whilst both the SiPass Server and Client can run on multiple Windows platforms, it is recommended
that where possible a single operating system be chosen for an entire installation.
The same SiPass integrated version, as well as the same build of SiPass integrated should be in-
stalled on the SiPass integrated server and on all clients (local and remote), within the same system.

*Some additional configuration settings are required to ensure that the specified versions of Windows
operating systems operate correctly with SiPass integrated. Please refer Appendix A contained within
the SiPass integrated MP2.65 Installation Guide for further information.

12

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.3 Microsoft SQL Server


The following table indicates the supported SQL Server software on which SiPass
integrated will run:

SQL 2012 (SP2) SQL 2012 SP2 SQL 2008 R2 SQL 2008 R2 SQL 2005
(32/64-bit) Express (32/64-bit) Express (SP3 or later)
(64-bit) (32/64-bit) (32-bit)
Yes Yes Yes Yes Yes

If there are no SQL server versions installed on the computer where SiPass
integrated is installed, SiPass integrated will automatically install a 32-bit version
of Microsoft SQL Server 2008 R2 Express.

NOTE
Sites with multiple clients and higher activity (for example, a large number of doors / cardholders / or
event transactions, involving more than 5 clients, 50 readers, or 10000 cardholders) are recom-
mended to purchase a higher performance version of SQL optimized for both scalability and perform-
ance (for example, SQL Server 2008 Enterprise). Please refer to the Microsoft website for more infor-
mation regarding SQL versions and performance at the following link:
http://www.microsoft.com/en-us/server-cloud/products/sql-server-editions/default.aspx
Failure to install the appropriate version of SQL Server may have an adverse impact upon the per-
formance of SiPass integrated.

4.4 .NET Framework


The following .NET Framework version is tested to be compatible with SiPass inte-
grated:

.NET Framework
Version 4.0

4.5 Web Client Browser Compatibility


Internet Explorer (IE)* Firefox Chrome
Min. version Version 24** Version 30.0.1599.101**
10 and higher

ü ü ü
*If using IE10 for the SiPass integrated Web Client, ensure that you have turned off
Compatibility View for the browser.
**These versions have been tested to be compatible with SiPass integrated
MP2.65.

13

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.6 Web Client Smart Device Compatibility


Apple Apple Samsung
SiPass int. iPhone iPad Galaxy
Web Client
ü ü ü

4.7 System Compatibility

4.7.1 Firmware

AC5100 ADD51x0 ADS52x0* AFI5100 AFO5100


(ACC-020 / ACC- (DRI) (SRI) (IPM) (OPM)
010)
Version 2.65.31 Version 3.34 Version 3.09 Version 2.32 Version 1.12
ü ü ü ü ü

ADE5300 AFO5200 ATI5100


(ERI) (8IO) (IAT-010)
Version 3.30 Version 1.02 Version 1.05
ü ü ü

DC12 DC22 DC800 IOR6


Mkl Version 1.36 Mkl Version 1.36 Version 1.23 Version 1.00
MKII Version 1.43 MKII Version 1.43

ü ü ü ü

AC5102 AC5200 Granta Mk3 Granta Mk3


(ACC-G2) (ACC lite) (ACC-Granta) Backboard
Version 2.65.31 Version 2.65.31 Version 1.29
Version 2.65.31
ü ü ü ü

4.7.2 Hardware

4.7.2.1 Controllers

AC5100 AC5100 AC5200 AC5200 AC5102


ACC Revision 3 ACC Revision 2 SR34i SR35i ACC-G2
ACC-020 ACC-010 Revision 1 Revision 1.4 Revision 3
ü ü ü ü ü

AC5200 Granta Mk3


SR35i MkII Revision 1
Revision 2
ü ü

14

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.7.2.2 Door Control

ADD51x0 ADS52x0 ADE5300 ATI5100 4322 4422


DRI SRI ERI IAT COTAG SWIPE
Revision D Revision B Revision A Revision A
ü ü ü ü ü ü

DC12 DC22 DC800 PD30/PD40


Rev 05 Rev 05 Rev. 04 Rev. 02
ü ü ü ü

4.7.2.3 I/O

AFI5100 AFO5100 AFO5200 4253 I/O IOR6


IPM Revision B OPM Revision A 8IO Revision A Rev. 04
ü ü ü ü ü

4.8 API / HLI Compatibility


The sections that follow provide information on the backwards compatibility of the
current interfaces available in SiPass integrated MP2.65 SP2.

4.8.1 HR-API Interface

SiPass integrated HR-API allows data to be accessed and maintained from any
programming language that supports COM automation.
SiPass integrated MP2.65 SP2 contains HR-API changes when compared to MP2.6
and earlier which means modification is required for any existing applications, that have
been built around versions previous to 2.65 HR-API.

4.8.2 Management/Enterprise Station API

SiPass integrated MS-API allows data to be accessed and maintained from any
programming language that supports COM automation.
SiPass integrated MP2.65 SP2 contains MS-API changes which does not require
modification to any existing applications, that have been built around versions previous
to 2.65 MS-API.

4.8.3 OPC A&E Server Interface

SiPass integrated supports OPC A&E version 1.0.

15

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.9 Digital Video Recorder (DVR) System Compatibility

4.9.1 Premium DVR Integration

Siemens Siemens Vectis HX Vectis iX


AX 4/8/16 SISTORE AX4 Lite

Version 2.6 Version 1.0 SDK 2.5.4 SDK 2.5.4

Version 3.5 Version 2.0

Version 3.6

Version 4.2.0

NOTE
For the above versions SISTORE AX / SISTORE AX 3.1 / General SISTORE option from the Type drop-
down should be selected from the DVR Switcher tab on the Component dialog in SiPass integrated

NOTE
If a search request is initiated using VSS_SDK, directed to a SISTORE AX device, and there are a lot of
short recorded sequences on the AX hard drive(s), it may take up to 15 minutes until a search result is
found. In this case it is recommended to increase the recording duration of the AX in order to prevent too
many short sequences from being generated.

Siemens Siemens Siemens Siemens Siemens


SISTORE SISTORE SX SISTORE NVS SISTORE CX1 SISTORE CX4/8
MX

Version Version 3.1 Version 2.90 Version 3.5 Version 3.5


2.90 SP2 SP2
Version 3.6

NOTE
For the above versions General DVR (VSS –SDK Compatible) option from the Type drop-
down should be selected from the DVR Switcher tab on the Component dialog in SiPass inte-
grated

4.9.1.1 VSS-SDK Compatibility

VSS-SDK Max. Resolution sup- Max. Bandwidth sup- Max. FPS


Version ported by ported by supported by
VSS-SDK VSS-SDK VSS-SDK
2.5.3.26 1920 x 1080 / 1280 x 16 MBit/s 30 fps
1024

Please note the limits above also apply to IP cameras connected to SiPass inte-
grated via RTSP (VSS-SDK Player)
16

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.9.2 3rd Party DVR Integration (Requires DVR-API Connection License)

Bosch Bosch Bosch Bosch Bosch Bosch


Divar 700 DivarXF DivarMR DivarClassic DiBos 8 BVIP*
Series
ü ü ü ü ü ü

Bosch Bosch DVTel DVTel


NBC-255 Video SiPass (F) SiPass (B)
Recording Integration Integration
Manager 6.2.2.1 6.2.2.4

ü ü ü ü

NOTE
*BVIP applies to Dinion IP, Flexidome, Extreme IP, AutoDome IP, VideoJet X
series and VIP X1600
For the above BOSCH versions Generic option from the Type drop-down should be selected from the
DVR Switcher tab on the Component dialog in SiPass integrated
For compatible versions and support, please contact DVTel or Bosch.
Bosch DVR-API version 2.0 was tested in a Windows 7, 64-bit environment.
For further support on the Bosch integration package, please contact your local Bosch support in your
region.

4.10 CCTV System Compatibility


4.10.1 Premium CCTV Integration

Siemens Siemens Siemens Siemens


SIMATRIX 648 SIMATRIX 164 SIMATRIX SYS SIMATRIX NEO
(VMx_0111.X08 or (VMx_0111.X08 or (VMx_0111.X08 or higher)
higher) higher)
ü ü ü ü

4.10.2 3rd Party CCTV Integration (Requires Connection License)

Pelco 6800 Pelco 6700 Pelco 9740 Pelco 9760


ü ü ü ü

17

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.11 Directly-connected IP Camera Compatibility


AXIS AXIS AXIS AXIS AXIS AXIS Siemens Siemens
207 212 PTZ* P1354 Fix M30007 Fix P5534* P7214** CCIXI345 CCIC1410-L
Camera Dom PTZ – Dom, Video Encoder
Live View
ü ü ü ü ü ü ü ü

NOTE:

– While the above cameras have been specifically tested, an IP camera using the RTSP protocol
should work properly. Please test before purchasing and installing onsite.

– For live streaming with IP Cameras, SiPass Integrated supports the RTSP as command protocol and
RTP for the data stream. The Codecs that are supported are: MJPEG, MPEG4, H264

– *PTZ Not supported

– **Only IN1 is supported

– If recording is required, the IP camera has to be connected via DVR

4.12 Intrusion Panel Compatibility

Intrunet SI 400 series SPC 4300, 5300, 6300


(Sintony 400) Intrusion System

ü ü

NOTE
AC5200 (ACC lite) controller does not work with SPC Intrusion system or Sintony 400.

4.13 Card Printer Compatibility

EDI Secure EDI Secure EDI Secure EDI Secure Datacard


XID Family XID Family XID Family XID Family Magna Class Series
560ie 570ie 580ie 590ie
ü ü ü ü ü

Fargo Fargo Fargo Fargo Fargo Fargo


HDP5000 HDP5000 Pro - Series High Definition Direct-to-Card Persona
with built-in with built-in (HDP600, (DTC500 Series) (C25)
OMNIKEY OMNIKEY HDP800)
5121 5321
ü ü ü ü ü ü

NOTE

The above table only lists those card printers that have been tested with SiPass integrated. Most Win-
dows compatible card printers should operate correctly with SiPass integrated 2.65. However, it is rec-
ommended that you test your card printer for correct operation before installation in a live environment.
Further, additional checks should be performed to ensure that your card printer is compatible with your
Operating System.

18

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility
4.14 MiFare Classic Card Encoding (while printing)

Fargo with GEM Fargo with GE- OmniKey Card- Fargo Fargo
Plus 680 SL en- MeasyAccess332 man SK21 HDP5000 with HDP5000 with
coder installed by encoder, installed built-in built-in
Interproc by Interproc OMNIKEY 5121** OMNIKEY
(www.intraproc.co (www.intraproc.co 5321**
m – GCI680 Driver) m – GCI680 Driver)
ü ü ü ü ü

**Supported for Single printing and encoding, and Batch printing and encoding

4.15 Enrollment Reader Compatibility


4.15.1 RS-232 Enrollment Readers

Siemens HID6055B GemPlus CGI680 GemEasyAccess 332 OmniKey


AR6201-MX Cardman
SK21
ü ü ü ü ü

4.15.2 RS-485 Enrollment Readers

CerPass Reader Protocol


ü

NOTE
When using an RS-485 output reader an RS485 to RS232 conversion unit must be used to connect
that enrolment reader to the serial port of the SiPass workstation client.

4.15.3 USB Enrollment Readers

USB-RIF/2 CardMan 5321


ü ü

NOTE
The USB-RIF itself is not a reader, but a device to which a reader may be connected. Once connected
the USB-RIF will convert the readers output into a USB signal for connection to a PC. Also note the
USB-RIF only supports certain reader types.
The USB-RIF has severe restrictions with reading card types. It can read 26bit Wiegand, 32 bit
Wiegand and all Siemens Clock/Data formats. No other formats are supported.

19

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility
4.16 Card Format Compatibility
4.16.1 Reader Connection Types

Wiegand RS-485 RS-232 Clock & Data


ü ü ü ü

NOTE
(DRI Version D1) does not support the connection of RS-232 type readers.

4.16.2 Siemens Proprietary Card Formats

CerPass/SiPass Siemens Corpo- 31-bit STG 36-bit Asco Siemens 52-bit


RS-485 rate Card
ü ü ü ü ü

4.16.3 Proximity Formats

26-bit 36-bit ASCO 27-bit Indala 27-bit Cotag HID Corporate Custom
(industry 1000 Wiegand
standard)
ü ü ü ü ü ü

4.16.4 Smart Card Formats

32-bit CSN 40-bit CSN 26-bit Standard * ASCO 36-bit HID*


(CSN32) (CSN40) (stored in sector) iClass UID
ü ü ü ü ü

NOTE
*SiPass integrated supports CSN, UID, and Data on-card for iClass HADP readers. Please note that
the format for Data on-card should be a maximum of 8 bytes of binary data (no special format, just a
64-bit card number).

4.16.5 Bar Code Formats

2 of 5 3 of 9 Encrypted Facility Code


ü ü ü ü

4.16.6 Magnetic Stripe Formats

Credit Card Encrypted Facility Code CerPass Magstripe Siemens Argina


(read only) Clk/Data
ü ü ü ü ü

20

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.17 Card Reader Compatibility


4.17.1 Siemens AR Range

AR6181-RX *AR6181-MS AR6181-MT AR6182-RX *AR6182-MS


ü ü ü ü ü

AR6182-MT AR6331-LE AR6331-CP AR6332-BI AR6332-CP


ü ü ü ü ü

AR6332-LE AR6381-MS AR6382-MS AR6473-RX AR6473-MT


ü ü ü ü ü

AR6473-LE AR6111-MX *AR6181-MX *AR6182-MX ARS6311- RX


ü ü ü ü ü

AR10S-MF AR11S-MF AR40S-MF AR41S-MF


ü ü ü ü

* These Siemens readers will support the MIFARE DESFire UID with a firmware
upgrade.

NOTE
Siemens readers with keypad, only function correctly when connected via RS485. The PIN may not
read correctly when connected in Wiegand or Clock/Data mode.

4.17.2 Readers Supporting the DESFire EV1 Card Technology

Siemens RS485 Siemens Reader Siemens Reader


UID Clk/Data UID Clk/Data Ex-
tended
ü ü ü

AR40S-MF AR10S-MF AR41S-MF AR11S-MF


ü ü ü ü

These above readers are all mapped to the Siemens Reader Card Technology,
and become available with the Siemens RS485 Clk / Data reader license. They
can be configured on the FLN Configuration dialog of SiPass integrated.

4.17.3 Siemens EM Proximity Reader Range

SP500-EM HD500-EM PR500-EM PM500-EM


ü ü ü ü

21

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.17.4 Siemens Miscellaneous

CX2M Magstripe CX2B Bar Code


ü ü

4.17.5 HID Proximity and MIFARE Classic

Prox Pro Prox Pro + Key- Thin Line II Prox Point MiFare 6055B
pad (CSN only)
ü ü ü ü ü

*HID iClass *HID iClass *HID iClass *HID iClass *HID iClass
(OSDP) (OSDP) R10 (HAPD/OSDP (HAPD/OSDP
RKL550 RP10 enabled) enabled)
R15 R30
ü ü ü ü ü

*HID iClass *HID iClass *HID iClass


(HAPD/OSDP (HAPD/OSDP (HAPD/OSDP
enabled) enabled) enabled)
R40 RK 40 RKL550
ü ü ü

*SiPass integrated supports readers that have an RS485 connection. However,


some readers may require optional Expansion Modules for this functionality.

22

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.18 Card Technology Compatibility


The following card technologies are compatible with the Siemens OSDP Reader.

Siemens Siemens OSDP Siemens OSDP Siemens OSDP Siemens OSDP


1 2 3 4 5
OSDP Custom Raw Mifare Facility Sector 7 26-bit
ü ü ü ü ü

Siemens Siemens OSDP Siemens OSDP


6 7 8
OSDP SiPort GID All HID Prox
ü ü ü

1
All data from the reader is the card number. The license is as Siemens reader
2
Custom Wiegand profile. License is as Custom Wiegand.
3
This is a Mifare Facility card, encoded by SiPass. The license is as Mifare Facility.
4
This is a 26-bit wiegand card, as encoded by SiPass onto a smart card.
The license is as Mifare 26-bit.
5
The license is as Siemens SiPort
6
This is a Siemens GID format. The license is as Siemens GID.
7
This is equivalent to AllHidProx – Wiegand data encoded onto a smart card. The license is as the ap-
propriate Prox. Card technology
(This is useful for iClass MultiProx readers).

4.19 Morpho 4G V-Station Reader Compatibility


The following 4G V-Station reader (previously known as L1 reader) versions have
been tested and verified as working with SiPass integrated:

*4G V-Station Readers sup- 4G V-Station Reader 4GSTSG


porting Vseries DLL Version 4.1.2.0
ü ü

*SiPass integrated supports 4G V-Station readers that have a Vseries DLL. How-
ever, some readers may require additional verification with the manufacturer re-
garding the compatible reader version that is equivalent to Version 4.1.2.0 in the
case of the 4GSTSG reader.
A separate license for using the Vseries DLL is required from the reader manufac-
turer.

23

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility
NOTE
The fingerprint template layout is defined using the reader setup tool but the enrolment can be per-
formed using SiPass.
The entire reader configuration is done with the reader setup tool, such as time schedules.
SiPass integrated supports card + fingerprint. It is not possible to use fingerprint-only as a credential in
SiPass integrated.
Using 4G V-Station readers, multiple fingerprints can be encoded on the Mifare Classic and Mifare
DESFire cards if the fingerprint is not configured to be stored in the SiPass database. Otherwise only
one fingerprint can be encoded on the smartcards using either Siemens readers or 4G V-Station
readers.
The above table only lists those cards that have been tested with SiPass integrated. Apart from the
listed readers all 4G V-Station readers that support SecureSDK, smart card option and fingerprint
format TEM 1:1 works with SiPass integrated. For reader specifics, please contact the reader manu-
facturer.

4.20 Granta MK3 Reader PIN Pad Type Compatibility


SiPass integrated supports the Pin Pad types 1, 2 and 3. The type can be config-
ured on the FLN Configuration dialog.
Please refer Chapter 6 of the 4101-3 Controller Installation Handbook for informa-
tion on Installation and Configuration.

1 2 3 0 1 2 3 1 2 3 A
4 5 6 4 5 6 7 4 5 6 B
7 8 9 8 9 A B 7 8 9 C
ê 0 # C D E F 0 F E D
Type 1 Type 2 Type 3

Note:
è For the 4422 Swipe module and the 4322 Cotag module, the keypad type
has to be selected on an extra Key tab during configuration.
è The system does not support entry of your own PIN for first-time use.
è An External Swipe reader, combined with a keypad, can be configured as an
M43 Keypad Type.

24

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.21 Signature Capture Tablet Compatibility


The following signature tablet range has been tested and verified as working with
SiPass integrated:

Topaz HSB (USB) signature capture pads


ü

4.22 Messaging System Compatibility


The following messaging systems have been tested and verified as working with
SiPass integrated:

Microsoft Exchange Microsoft Exchange Outlook 2000 Outlook 2003


Server 2000 Server 2003
ü ü ü ü

NOTE
Email forwarding may not be supported or may not support the sending of emails externally, under
certain corporate email conditions or specific corporate implementations.

For venue booking email notifications configured with Exchange Server option, the
following are the supported Exchange Server versions:
· Microsoft Exchange Server 2007 (SP3) or newer

25

Siemens Schweiz AG 12.2014


SiPass integrated Installation Compatibility

4.23 Server Redundancy


The following server redundant software has been tested with SiPass integrated:

Stratus Technologies Stratus Technologies Stratus Technologies


EverRunFT EverRun2G EverRun MX
(supported with SQL 2005) (supported with SQL 2008) (supported with SQL 2008)
ü ü ü

4.24 Offline Door System


The following Offline Door System has been tested with SiPass integrated:

SALTO
Version 11.03.02.190
ü

NOTE
· The SHIP protocol (version 1.8f) should be enabled for this feature.
· Only the 32 Bit version of the SALTO software should be used
· Refer to the Salto documentation for the maximum length of text or other potential limitation.

4.25 Virtualization

Citrix Microsoft Windows Microsoft Windows


Xen App Server 2003 Server 2008
Version 5 Terminal Services Terminal Services

ü ü ü

NOTE
It is highly recommended that suitable hardware and system specifications form the basis of your
system.

4.26 For more information…

Contact:
siveillance.support.industry@siemens.com

26

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2

5 Enhancements and Quality Improvements


for SiPass integrated MP2.65 SP2
The sections that follow outline the improvements and fixes made since SiPass in-
tegrated MP2.65 SP1 was released.

5.1 Enhancements
The following sections provide a summary of the enhancements to
SiPass integrated MP2.65 in Service Pack 2.

Enhancement Summary

OSDP Encrypted SiPass integrated now supports the configuration


Communication & ARxxS- of ARxxS-MF readers, supported by the OSDP
MF Reader Configuration encrypted communication protocol.
Enhancements For details on configuration, refer to the SiPass
integrated User Manual.
Operators can now create multiple holiday calen-
dars in the system, which can be assigned to con-
trollers.
As an enhancement, the system also provides
Calendars & Additional
support for 6 extra holiday types (in total 8), which
Holiday Types
can be assigned to a time schedule.
The time schedule dialog has been enhanced to
support the extra holiday types.
For systems using Salto, there is a new holiday
mapping of SiPass Holiday 3 to Salto Special2
For cardholders who have been assigned venue
bookings, SiPass integrated can now send notifica-
Email Notifications for tions via email, using Microsoft Exchange or the
venue booking SMTP protocol, to cardholders who have their
email address configured in the system.
For details on how to configure email notifications,
refer the SiPass integrated User Manual.
New enhancements have been introduced that
SPC Enhancements allow the user to clear alarms of an individual
zone/input, view and isolate unsealed
zones/inputs, and generate respective audit trail
messages.

Management Station API


Support for New Output & Enhancements have been introduced for output
Access Point States point enabled/disabled states, and access point
enabled/disabled states.

27

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2
The HR-API has been enhanced to support filtering
HR-API Enhancements of all non-base credentials by using two new filters,
and retrieving information about all custom fields
configured in the system
The web client now displays a cardholder’s image
Web Client enhancements on the cardholder editor, search and venue book-
ing pages.
The user can change the Reader Point mode from
Advanced Security “Card+PIN Arm/Disarm” to “Double/Single Arming”
Programming using ASP.

The ACC can now be configured with the SiPass


server host name instead of IP address. To support
ACC DNS Support this enhancement, the IP address of at least one
DNS server will need to be set in the ACC.

Image verification enhancement.


- Support Host timeout
Image Verification AllowAccess/DenyAccess options.
Support to display "image verification timeout
access allowed/denied" in audit trail

28

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2

5.2 Fixed Issues


This section details known issues fixed in SiPass integrated MP2.65 SP2.

Type Description

Warning message introduced if no time


Access Assignment schedule is selected when adding an access
rule.
Fix exception in Access Level dialog if no time
Access Level
schedules get populated.
Fix grid selection when control loses focus and
Access Level & Group tab key shortcuts in Access Level and Access
Group dialogs.
Alarm Queue was showing alarms to opera-
Alarms tors that didn’t have rights to the associated
points
Mustering report for Anti-Passback Area is
APB area
sometimes inaccurate
Cannot increment / decrement the counter in
ASP
ASP with a non partitioning workgroup
No message in audit trail when DVR switcher
Audit Trail
offline (e.g. SISTORE CX device)
Audit trail context menu commands to
Audit Trail add/remove cardholder from APB area were
disabled
Inaccurate audit trail with OSDP encryption
Audit Trail
mode “fall back”
Fix input point name lookup failure in audit
trail, when sending manual commands to
Audit Trail
normal input points where an SPC/Sintony
device may be attached on another FLN.
Some Cardholder General Data records were
Backup not backed up if equal to or more than 60
characters total for a cardholder

Backup Fix backup issue with cardholder null end date

On Windows Server 2012, System/Local Set-


tings options in SiPass backup are disabled
Backup even when adminstrator is logged into Win-
dows, options are enabled only when SiPass
client is run as administrator
Fix memory leak that occurs in every backup
Backup
operation
Warning message if card number already in
Bulk card creation
use during bulk card creation.

29

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2
Show error message if no more PINs are
Bulk card creation
available during bulk card creation.
SiPass 2.65 search by "PIN ERROR disabled"
Cardholder
not working
Fix - restored cardholders from 2.50/2.60 that
didn't have custom fields configured will throw
Cardholder an exception when deleting on 2.65.
(work around is to save the cardholder on 2.65
and then delete it)
Cardholder "New" Button "Saves" the Card-
Cardholder
holder without any prompting.
Issues with custom fields data changes not
Cardholder being updated in the audit trail or through the
HR API employee events
Searching for a cardholder can create a new
Cardholder
cardholder
Issue of "different cardholder can have cre-
Cardholder dentials with same PIN even when credential
profile PIN mode is Pin As Card”
Fix results from Cardholder Search using Cus-
Cardholder
tom Fields.

Cardholder Add scroll bar to General Data control

Search Cardholder dialog doesn’t always pop


Cardholder
up on top of Cardholder dialog
Un-voiding cardholder which was void and
Cardholder ACC initialized would lose the access rights in
the ACC.
Some of the PINs generated in the PIN selec-
Cardholder
tion dialog are not actually available
Cardholder Password text field should be lim-
Cardholder
ited to 32 characters
Problem in arming intrusion areas for sites
Cardholder with PIN AS CARD mode – “Void Card 0, Fa-
cility 0” message
Issue where cardholder search browser
Cardholder shows X if search button is clicked while
search browser is open
Fix for data errors resulting when updating a
Cardholder cardholder number with 'PIN as Card' mode

After saving cardholder, the cardholder dialog


Cardholder
should show the first (left-most) tab by default
Duress PIN does not work for ACC G2 unless
Cardholder
you initialize the controller
Should be possible to search cardholder by
Cardholder
the assigned access group
Visible report (custom) columns from SiPass
Cardholder
Reporting does not always match what is seen
30

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2
in Cardholder Search.

Fix for cardholder dialog closing when assign-


Cardholder
ing a card template which contains magstripe.

Cardholder Support to search after return key pressed

Error handling of some new MP2.65 dialogs


Client
does not give a meaningful message
Client hangs after unlocking workstation with a
Client
different user name

Client Enlarge the License Details dialog

Change error message (when retrieving con-


Components troller memory usage), so that it won't be con-
fused with a memory usage exception
Fix ACC memory usage retrieval with locale
Components other than english
Error if the credential profile PIN length should
Credential Profile be changed and a 2nd Credential profile ex-
ists.
Issue of "error appears when saving custom-
Custom Pages
pages with no changes".
When using a compulsory custom cardholder
field (dropdown with lookup table), that popu-
lating the fields in a specific order and saving
Custom Pages the cardholder record results in the dialog be-
having as if the compulsory field was not
populated
Issue of "timeout exception raised when up-
Custom Pages
date attachment of cardholder"
It is not possible to place a Button in more
Custom Pages
than one tab
When creating new symbol/drawing and se-
Drawing lecting bright green colour, this will deactivate
the window and send to back of MDI view
If the DVR operation dialog is opened and
nothing chosen (dialog empty) the client
DVR
crashes as soon as the Display button is
pressed
If Windows user does not have local admin
permissions, then there are the following prob-
lems:
DVR
- no live picture in DVR dialog
- in components you see the DVR is online,
but no version informations shown.
AR6201-MX enrollment reader can only en-
Encoding
code using COM1 port

Encoding Unable to Delete Unused Encoding Profiles

Smard Card: facility code is not encoded into


Encoding
the smart card with Mifare facility access con-
31

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2
trol

Encoding Biometric encoding failures

Delete expired rights via host event task not


Event Task
possible
Message Forwarding to E-mail via Host Event
Event Task
task failed.
Resize combo boxes drop down lists in Event
Event Task Task dialog to accommodate long point
names.
External alarm monitoring: event tasks were
External Alarm Monitoring
incorrectly generated and saved
FLN Configurator sometimes throws an un-
FLN Configuration
handled exception
ERI is missing iClass OSDP in reader card
FLN Configuration
technology drop box
Fixed crash occurring when opening FLN Con-
FLN Configuration figuration dialog if Components dialog was
opened just before.
GSM modem messaging problem, timeout
GSM Messaging messages observed in audit trail

Should be able to write employee properties


HR-API "SelfAuthorise", "APBExclusion", and "Super-
visor"
HR-API Sample Program:
- In events menu, renamed 'Credential Profile'
to 'Employee Credentials'
HR-API - Fix subscription click to Employee Credential
events
- When closing application, first use the HR-
API to unsubscribe and logoff
Employee SQL query on some sites was oc-
HR-API curring very slowly, causing timeouts in the
HR-API GetEmployees() call
HR-API Sample:
HR-API - Fix GDI+ exception when trying to save the
same image for a cardholder
Should be able to use reference field as
unique identifier of employee in import/export
tool.
Import/Export tool
Allow user to set specific employee id when
creating new employees with Import/Export
tool
Include "company" and "restricted" custom
Import/Export tool
fields in Import/Export tool
Import/Export tool:
- When adding or removing an image to a
Import/Export tool cardholder record, ensure the
ImageUpdatedDateTime property is updated
- When adding/updating a cardholder, ensure
32

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2
the LastUpdatedDateTime property is updated

If import type selected is xlsx, the default file


Import/Export tool filter selected in file selection dialog will be xls.
It should be xslx filter selected by default.
Fix issue on partial ACC initialization failing to
Initialisation send access point assigned directly to card-
holders and workgroups
Upgrade installation should stop the SiPass
Installation service itself after confirming with user. Previ-
ously had to be stopped manually by user.
Ask user to restart service after license details
Installation
updated.
Repairing SiPass installation wipes the Data-
Installation
base
There should be a warning concerning possi-
Installation
ble data loss for a failed upgrade.
Operator Log Book Entry Reports not Work-
ing.
- Remove old Crystal LogBook report
Log Book report
from menu/toolbar
- New Log Book reports in SiPass Ex-
plorer
Fix issue where the channel was not released
Logon after client connection is lost (without logoff)
which will affect the client license count.
MS-API improvements
- Add comments to each object state in MS-
API to aid 3rd party developers
- Fix MS-API state mapping for SiPass access
state 20 - should be Self Authorise, but was
mapping to 'card activates floor' state which is
Management Station API deprecated
- Fix MS-API state mapping for SiPass unit
states 10 and 11 - should be 'primary DB ini-
tialised' and 'primary DB incomplete', but was
mapping to 'memory warning' and 'memory
overflow' states which are deprecated
Allow access command wrongly sent to ERI
MM8000
doors for MM8000 system.
SiPass audit trail can stop showing new
MM8000 events when used in combination with
MM8000
Enlarge controls and add scroll bar to operator
Operator Group
group dialog's list boxes
Fixed operator partitioning for following:
- Time Schedule dialog
Operator partitioning - Workgroup dialog
- Access Group dialog
- Access Level dialog
33

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2
- Work group dialog

Disable work group button if operator does not


Operator partitioning
have work group privileges.
Time Schedule tab visible in Access Assign-
Operator partitioning ment dialog if operator does not have Time
Schedule privilege.
Access Privilege button did not follow operator
Operator partitioning
privileges
Update Cardholders and Create Cards buttons
Operator partitioning
did not follow operator privileges.
The report for Cardholder Filtered Point Ac-
Reporting cess does not conform to the Filter Conditions
as defined when customizing the report.

Reporting Visitor's card history bug

Support Card Print Information in Sipass Re-


Reporting
porting "Cardholder All Fields".
Cardholder Filtered Point Access report con-
Reporting
tains a Photo field but does not display photos
Performance improvement for "Audit Trail -
Reporting
Access Cardholders Detail" report.
Cardholders with images listed in 'Cardholders
Reporting
with no Images' report
Show cardholder image in "Cardholder Access
Reporting Policies”, “Cardholders Point Concise" and
"Cardholder Point detail" report.
Inactive Cards-30 Day Threshold report some-
Reporting times takes a long time with a large database
with SQL2012
Cardholders Point Details report should list
Reporting
non-partition workgroups access.
Cardholders - Work Groups report should list
Reporting
non-partition workgroups
After restoring into MP2.65, some modified
Reporting audit trail reports may not show data due to
incorrect storage of report filter configuration
Unit report does not always show 'Communi-
Reporting cating' status for online units, particularly after
initialising
Actionable reports with actions of Void Card or
Reporting
Void Cardholder were not working

'Audit Trail - Access Cardholders Detail' report


Reporting
was always returning an empty result
The correct removal command is not sent to
Salto Salto when Access group with Salto points is
deleted in SiPass
Salto enhancement - Holiday mappings of
Salto
SiPass Holiday3 to Salto Special2
34

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2
Salto Door and Zone can be deleted only from
Salto system side. The delete button should
be disabled on SiPass for Salto Door and
Salto Zone.
Fix for error when trying to remove Salto sys-
tem with zones from component dialog.
Ability to send the card number as a plain
number in the Salto ROMCode field. ROM-
Salto Code format is configurable through server
App.config file. By default use the original for-
mat and not the plain number format.
If there is an access level with Salto doors,
and later all doors are removed from it, the
Salto cardholders who reference it not having the
doors removed from the SaltoUser.

On Download, if access group and cardholder


don't have Salto door/zone, it will remove the
equivalent SaltoUserGroup and SaltoUser
Salto
from the Salto system. (Previously it was not
removing and just updating with empty access
rights)
If there is an access level with Salto doors,
Salto and later all doors removed from it, the doors
are not removed from the Salto system.
Delete Salto units from SiPass components.
The Upload will remove from SiPass if re-
moved from Salto (fixed issue with refreshing
Salto the Component dialog when Door/Zone is re-
moved during Salto upload).
Door and Zones can only be removed from
Salto system.
Not possible to encode a card if no Salto rights
assigned.
Salto Cardholder without Salto access, but using the
smartcard profile with Salto binary data con-
figuration, should encode the smartcard.
Time schedule changes not transferred to Sal-
to.
Salto
Changes to Time Schedule linked to Salto
timezone not being propagated to Salto.
Support new intrusion messages
SPC (“All Alarms Cleared”, “All Bells Silenced”) and
commands (SPC input clear alarm)
Door icons without names in System Status
System Status
dialog
Time & Attendance Data Export Format - If
Windows regional settings change for time
Time & Attendance
format to remove ':' separator, T&A data ex-
port does not use this time format.
When configuring a T&A Calculation report
Time & Attendance using an Absolute time period and saving it,
the Begin Time does not always save and
35

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2
changes to the current PC time, not the saved
time.
In time schedule dialog, when adding a day:
- Currently warning user if end time is less
Time Schedule than start time, but also check if end time is
equal to start time on the same day.
Time Schedule dialog - If time period is the
same start and stop day from 0000 to 2400,
Time Schedule increment stop day of the week correctly. Pre-
viously, Friday 0000-2400 was converting to
stop day of Monday
Add Graphical View UI to Time Schedule dia-
Time Schedule
log

Time Schedule Sort time periods by start day

Prevent editing of day names in time schedule


Time Schedule
dialog

Time Schedule Enlarge Time schedule dialog.


Number of time intervals per time schedule
Time Schedule limited to 20.
Add searching functionality in time schedule
Time Schedule dialog
(Windows Server 2012) New Custom page
Visitor
caused loading error in Visitor dialog.
Visitor dialog showing unhandled exception
Visitor
adding a new Visitor
Issue of "visitor is still void even saving visitor
Visitor with void cardholder unchecked in visitor dia-
log"

Web site Added tooltip to venue bookings.

Implemented cardholder image functionality


Web site on the cardholder editor, search and venue
booking.

Web site Fixed showHeader bug in week calendar

Web Browser issues are shown on the SiPass


Web client in Windows Server 2012 R2
Web site
IE id was changed in Windows Server 2012
R2, which was added to the compatibility list.
Failure to create recurring venue booking on
Web site
web site
Web client can display a cardholder image not
Web site
specifically assigned to the cardholder
When access rights are being assigned to a
Web site cardholder, the default access type selected
should be “Access Group”, not “Access Point”
36

Siemens Schweiz AG 12.2014


Enhancements and Quality Improvements
for SiPass integrated MP2.65 SP2

Web site Fix cardholder image display ratios

37

Siemens Schweiz AG 12.2014


Keyword index

6 Keyword index

. M
.NET Framework, 12 Modem Compatibility, 18

A S
Access Assignment, 8 System Compatibility, 13

C V
Card Format Compatibility, 20 Venue Booking, 9
Card Printer Compatibility, 19 Venue Management, 9
Card Reader Compatibility, 22
CCTV System Compatibility, 17 W
Web Client, 9
E Windows Patches and Hot Fixes, 7
Enhancements, 29

I
Installation Compatibility, 8, 11
Intrusion Panel Compatibility, 18

38

Siemens Schweiz AG 12.2014


Issued by
Siemens Schweiz AG
Building Technologies
IC BT SSP ES
Gubelstrasse 22 © 2014 Copyright by Siemens Schweiz AG
6300 Zug, Switzerland
Data and design subject to change without notice.
www.buildingtechnologies.siemens.com Supply subject to availability
Document no. A-100083-1_a
Edition 10.2014

Das könnte Ihnen auch gefallen