The Rosemount™ Wireless

Pressure Gauge
Introducing the New:
Rosemount™ Wireless Pressure Gauge
• Reduce Maintenance Challenges
– Get up to 10 years of reliable readings through industry-proven, pressure
sensor technology
– Reduce common mechanical gauge failures caused by vibration, pulsation
overpressure and other environmental factors
– Have confidence in pressure gauge health with local indicator light
• Improve Personnel Safety
– Keep people out of hazardous areas by minimizing operator rounds
– Gain peace of mind with overpressure ratings from 1.5x to 150x and 2 layers
process isolation
• Access Pressure Data Continuously
– Get accurate readings as frequently as once a minute with WirelessHART®
technology
– View pressure reading locally with large 4.5-inch (114 mm) gauge face

Learn more: www.EmersonProcess.com/Rosemount-Wireless-


Pressure-Gauge
Introducing the New:
Rosemount™ Wireless Pressure Gauge
WirelessHART® Protocol Overpressure Rating
– Work smarter and eliminate – Rated up to 150x the full scale pressure
unnecessary maintenance
that puts operators Gauge Capabilities
at risk
– ASME B40.7 - Grade 2A
– Up to 750 ft. (225 m)
accuracy
communication range
– ½″ male-NPT and G½ A DIN
male process connection
– Up to 4,000 psi range (gauge,
Gauge Lifespan absolute, compound and
vacuum)
– Reduce traditional
gauge failures – 15 Engineering unit options
caused by vibration, (psi, kPa, bar…)
overpressure, line – Process temperature limit
pulsation and other -40 to 250 ºF (-40 to 121 ºC)
factors
Pressure Readings
Manifolds and Remote – Solid-state piezoresistive pressure
Seals Offering sensor eliminates mechanical parts
– Full range of process connections leading to more reliable readings
available with manifolds and and a higher overpressure limit
remote seals factory assembled
and leak tested Device Status Indication
– Ensure device health with
local status indication
Learn more: www.EmersonProcess.com/Rosemount-
Wireless-Pressure-Gauge
Isolation Barriers Increase Personnel Safety By Keeping
Process Fluid Where it Belongs; In the Pipe

Piezioresistive Pressure Sensor Bourdon Tube

Multiple Process Isolation Barriers - Standard Limited Process Isolation


 Keep process fluid inside the pipe  Process fluid is allowed to exit the pipe
 Increase personnel safety
1 1st Barrier
Tube

2 1st Barrier
Isolating Diaphragm 2 Optional 2nd Barrier
Seal Assembly

2nd Barrier  Potential risks:


Sensor Assembly

1
Optional 3rd Barrier
Seal Assembly
3
“Looks Normal” – But Internal Cracked Casing - Loss of Media
Bourdon Tube is Damaged or Fill Fluid
Overpressure Resistance Helps You Have Confidence in
Reliable and Repeatable Pressure Readings

Piezioresistive Pressure Sensor Bourdon Tube

High Overpressure Resistance - Standard Minimal Overpressure Resistance


 Designed to maintain structural integrity across  Excess pressure deforms bourdon tube
various process pressure fluctuations
‘Unknown’
 Accuracy of the sensor is does not degrade as Pressure
higher process pressures are introduced OR
Undocumented
Overpressure
Event

 Potential Risks:
Up to 150x of
Scale Range

Overpressure: The maximum amount of pressure that can be applied to a


sensing device without causing damage “Looks Normal” – But Internal Cracked Casing + Loss of Media
Bourdon Tube is Damaged
Burst Pressure Limit Allows For Unparalleled Safety Against
Any Potential Breach of Pressure Containment

Piezioresistive Pressure Sensor Bourdon Tube

Burst Pressure - Standard Minimal Burst Pressure Resistance


 Designed to maintain structural integrity  Excess pressure causes unintended
against extreme process pressures catastrophic device failure
 If isolating diaphragm is compromised, process
is contained to sensor assembly
2 3
0 0

1 4
0 0

Sensor Assembly 0 5
0

Up to 11,000 psi
(758 bar)

 Potential Risks:
 Injury to Personnel
Burst pressure: The maximum amount of pressure that can be applied to a
 Asset Health
without causing a breach of pressure containment.  Environmental Consequences
Robust Product Design and Decreased Number of
Mechanical Components Extend Product Longevity

Robust Design + Piezioresistive Pressure Sensor Bourdon Tube

Reduced Mechanical Components - Standard Mechanical Components + Linkages


 Designed to maintain structural integrity across  Vibration and Pulsation wear components
various process pressure fluctuations
 No case filling required
Components
 Components:  Tube
 Linkages
 Pins
 Gears

 Potential Risks:

Solid State Electronics Pressure


Sensor Radio/Antenna Reading

Cracked Glass Disconnected Loose Dial


10-year installed life Violent Shaking
or Casing Dial
Local Indication of Device Health Allows Personnel to
Have Confidence in the Displayed Pressure Reading

LED Local Status Indicators

Local Indication of Device Health - Standard Unable to provide insight to device health
 Leave your wrench on the bench  Can displayed pressure be trusted?

Functioning Properly

Battery is Low
 Potential Invisible Symptoms:
 Hairline crack in bourdon tube
 Deformed bourdon tube
Battery replacement required
OR  Loose mechanical components or linkages
Blinks Every Second Device is malfunctioning

Das könnte Ihnen auch gefallen