Service Training

MALAGA

301.5 MHEX

V. IMPLEMENTS

Thorben
MAY 1998
301.5 MHEX
CHAPTER : Implements

Page: 2
301.5 MHEX
CHAPTER : Implements

1. Accumulator

2. Pilot Pressure Nipple

(Located in boom circuit - not adjustable)

Page: 3
301.5 MHEX
CHAPTER : Implements

1. Manual Boom Lowering

Page: 4
301.5 MHEX
CHAPTER : Implements

CONFLUENCE VALVE

SINGLE COMBINED
FLOW FLOW

Pilot Tank
Pressure

Port PA
Port PA

Port PB
Port PB

Pilot
Tank Pressure

The Caterpillar 301.5 MHEX is equipped with the combined


flow system.

Page: 5
301.5 MHEX
CHAPTER : Implements

Unload Position
(Single Flow System)

Auxiliary 0 Kgf/cm2 Swing


Circiut Motor
Pilot
Pressure
P3

P2 P3

Tank

Tank
Tank Tank

When the safety lever is in the up positiom, the pilot


pressure is cut and the P3 flow is connected to the tank
line.

Boom swing, blade and swing can not be operated.

Page: 6
301.5 MHEX
CHAPTER : Implements

Single Flow System

Auxiliary Swing
Circiut Motor
35 Kgf/cm2

P3

Pilot
Pressure

P2 P3

Tank
Tank
Tank Tank

When the safety lever is in the down position, pilot


pressure is applied to port PA and shifts the valve to the
single flow position.

This position of the valve seperates the flow from P2 and


P3.

Page: 7
301.5 MHEX
CHAPTER : Implements

Combined Flow System

Tank
Auxiliary Swing
Circiut Motor

P3

P2 P3

Pilot
Pressure

35 Kgf/cm2
Tank Tank
Tank

When the safety lever is in the down position, the pilot


pressure is applied to port PB and shifts the valve to the
combined flow position.

This position of the valve allows the auxiliary valve to work


with the combined flow of P2 and P3.