Beruflich Dokumente
Kultur Dokumente
Technical specification
table 1
GUN NAILING recommendations
COIL NAILER NAILS
Manufacturer Name Manufacturer Name Size
Hitachi VH650 coil nailer Otter Galv. coil nail 38mm x 2.5mm dia.
45mm x 2.2mm dia.
50mm x 2.2mm dia.
Paslode Impulse compact nailer Paslode Impulse DekFast® 50mm 50mm x 2.87mm dia.
(B20544) Value Pack (B20561V)
Impulse DekFast® 50mm 50mm x 2.87mm dia.
Handy Pack (B20557)
Stanley-Bostitch N80C coil nailer Stanley-Bostitch AC45P250 gal coil nail 45mm x 2.5mm dia.
Senco SCN-60 coil nailer (fitted with Senco BTN 45 ADB Weatherex gal 45mm x 2.5mm dia.
adjustable depth of drive) and Sencoted
Notes
Nail gun manufacturers have supplied the information contained in this
1. Fasteners with equivalent dimensions, (ie head size and shape, shank
table. Should a nail gun model or nail shown in the table not be available,
diameter and length to those above) are acceptable for use.
please contact the relevant nail gun manufacturer for advice.
2. All fasteners are to be galvanised or suitably coated for intended
If the nail gun overdrives sheets, contact nail gun manufacturer for advice.
external application.
3. Nailing guns must be fitted with flush drive attachments.
4. Some nailing guns incorporate an adjustable head set to control nail
depth (eg Duo-Fast coil nailer and Senco coil nailer.)
5. When gun nailing, apply pressure to the face of the cladding by
holding the cladding against the stud to reduce blow out at back of
the sheet.
table 3
boxed eaves: maximum bearer and fastener spacing - 6mm sheets (including 7.5mm hardiEgroove lining)
Sheet edges supported on framing
6.0mm HardieFlex eaves lining and sheets; Versilux lining and 7.5mm HardieGroove lining.
maximum eaves as 4055 within 1200mm of the external elsewhere in building
width (mm) wind classification building corners
Trimmer spacing (mm) Fastener spacing (mm) Trimmer spacing (mm) Fastener spacing (mm)
To 600 maximum N1 1050 300 1200 300
N2 950 300 1200 300
N3/C1 600 250 1200 300
N4/C2 500 200 750 300
N5/C3 450 150 600 225
N6/C4 400 125 500 200
> 600 to 1200mm N1 850 300 1100 300
maximum N2 750 300 1100 300
N3/C1 650 225 900 300
N4/C2 550 175 750 250
N5/C3 450 150 600 225
N6/C4 400 125 550 175
table 4
Notes
1. Fastener spacings based on using 2.0 x 30mm galvanised fibre
cement nails.
2. Locate fasteners not less than 12mm from sheet edges and 50mm
from sheet corners.
3. *600mm wide simple-spanning eaves in N1 wind classifications under
Serviceability Limit State wind loads, may result in deflections up to
11mm (span/55). In addition the edges of the fibre cement sheet
should have adequate bearing in the recess groove of the fascia.
TABLE 6
RAKED EAVES - 6mm sheets (including 7.5mm hardiEgroove lining)
Maximum batten and fastener spacings
6mm HardieFlex sheet, Versilux lining and 7.5mm HardieGroove lining
wind classification within 1200mm of the external elsewhere in building
building corners
To AS 4055 Max. batten spacing (mm) Max. fastener spacing (mm) Max. batten spacing (mm) Max. fastener spacing (mm)
N1 500 300 600 300
N2 500 300 600 300
N3/C1 450 300 600 300
N4/C2 400 150 450 300
N5/C3 300 200 450 200
N6/C4 300 100 375 200
Notes
1. Fastener spacings based on using 2.8 x 30mm galvanised fibre
cement nails.
2. Locate fasteners not less than 12mm from sheet edges and 50mm
from sheet corners.
table 8
soffit lining - 6.0mm sheets (including 7.5mm hardiEgroove lining)
Maximum framing and fastener spacings
6mm HardieFlex sheets, Villaboard lining, Versilux lining and 7.5mm HardieGroove lining
wind classification within 1200mm of the external elsewhere in building
building corners
To AS 4055-1992 Max. batten spacing Max. fastener spacing Max. batten spacing Max. fastener spacing
(mm) (mm) (mm) (mm)
N1 500 300 600 300
N2 500 300 600 300
N3/C1 450 300 600 300
N4/C2 400 150 450 300
N5/C3 300 200 450 200
N6/C4 300 100 375 200
table 9
soffit lining - 9.0mm sheets
Maximum framing and fastener spacings
9.0mm Villaboard lining/Versilux lining
wind classification within 1200mm of the external elsewhere in building
building corners
To AS 4055-1992 Max. batten spacing Max. fastener spacing Max. batten spacing Max. fastener spacing
(mm) (mm) (mm) (mm)
N1 600 300 600 300
N2 600 300 600 300
N3/C1 600 250 600 300
N4/C2 450 200 600 250
N5/C3 450 150 600 200
N6/C4 400 125 450 200
(iii) Soffits directly under roofing (Less than 600mm). For soffits directly 5.2.3 Transverse to the frame jointing
under roofing, Versilux sheets is recommended. JH PVC straight jointers or the JH PVC Eave and Soffit Joiner 6mm and
4.5mm are installed progressively with the sheets. See Figure 21.
Where Villaboard lining is used:
For insulated roofs (min R2.0 insulation) the maximum spacing for a 5.3 butt joint
control joint is 3.6m. For uninsulated roofs the maximum spacing for 5.3.1 General
a control joint is 2.4m as shown in Figure 13. Use butt jointing where an exposed joint appearance is acceptable. Butt
the sheets together over the framing member leaving a 0.5mm gap [see
(iv) Existing structures. Where a new installation intersects with an Clause 5.1.1(b)] and fix sheets at spacings given in applicable table.
existing structure or where a control joint is required by the design See Figure 22.
of the structure.
5.3.2 Vee joint
5.1.2 Non-set joints The use of a bevel edged sheet will exaggerate the simple butt joint,
a) Typical giving a butt vee joint. See Figure 23.
For this typical joint, a framing member is required each side to support
the sheet edges - see Figure 14. 5.3.3 Expressed jointing
Where you want the soffit to have directional emphasis, joints can be either:
In bushfire prone areas, a pressed metal expansion strip should be 1. Using the JH PVC Eave and Soffit Joiner 6mm, see section 5.2 and
included behind the sheets to prevent sparks and ignited material from figure 7.
entering the space below the roofing. 2. Leaving a gap between square cut sheet edges. Sheets to be
supported by framing. The gap is backed with durable corrosion
b) On top hats resistant metal flashing to cover frame beneath joint, see figure 24.
For this joint, two abutting top hats fixed to roof purlins are required, one
supporting each side of the sheet edges, but with only one edge fixed,
with the other top hat taking the fixing of the previously noted unfixed 5.4 flush jointing
sheet. See Figure 15. The maximum cantilever distance from fixing to 5.4.1 General
sheet edge is 100mm. Flush jointing is used with Villaboard lining to set both the long side
recessed edges and short side square edges of the sheet.
c) With socket
For this joint, a 50mm wide strip of HardieFlex sheet or Versilux lining is Flush jointing of Villaboard lining, with its recessed edges on the two long
bonded to the top of one soffit lining sheet with James Hardie joint sides, requires the use of perforated paper reinforcing tape, embedded in
sealant. The socket must be free to move over the face of the opposite James Hardie base coat. Self adhesive fibreglass tapes or woven linen
sheet. See Figure 16. The socket should be stopped 5mm short of the tapes should not be used.
face of the interrupting top hats.
C. Finishing Coat
9. Using a straight trowel, apply a coat of James Hardie Top Coat
280mm wide centrally over the joint and feather out the edges.
10. Apply a finishing coat to fastener heads, feathering out the edges.
Allow to dry before sanding, usually 24 hours.
cutting INDOORS
Cut only using score and snap, hand guillotine or fibreshears
n
drilling/other machining
When drilling or machining you should always wear a P1 or P2 dust mask Fibreshear
and warn others in the immediate area. An electrically powered, fast, clean and effortless way of cutting James
important noteS
Hardie building products, especially around curves such as archways.
1. For maximum protection (lowest respirable dust production), James Make fibreshear cut on the ‘off-cut’ side of the line to allow for the
Hardie recommends always using “Best” - level cutting methods where thickness of the shear.
feasible.
2. NEVER use a power saw indoors.
3. NEVER use a circular saw blade that does not carry the HardieBlade® logo.
4. NEVER dry sweep - Use wet suppression or HEPA vacuum.
5. NEVER use grinders.
6. ALWAYS follow tool manufacturers’ safety recommendations.
7.2 Durability
7.2.1 Resistance to moisture/rotting
Eaves and soffits have demonstrated resistance to permanent moisture
induced deterioration (rotting) by passing the following tests in
Hole-Forming accordance with AS/NZS 2908.2:
For smooth clean cut circular holes:
n
Mark the centre of the hole on the sheet. n
Water permeability (Clause 8.2.2)
n
Pre-drill a pilot hole. n
Warm water (Clause 8.2.4)
n
Using the pilot hole as a guide, cut the hole to the appropriate diameter n
Heat rain (Clause 6.5)
with a hole saw fitted to a heavy duty electric drill. n
Soak dry (Clause 8.2.5)
For irregular holes:
7.2.2 Resistance to fire
n
Small rectangular or circular holes can be cut by drilling a series of small
The Eaves and soffits is suitable where non-combustible materials are
holes around the perimeter of the hole then tapping out the waste piece
required in accordance with C1.12 of the Building Code of Australia.
from the sheet face.
n
Tap carefully to avoid damage to sheets, ensuring the sheet edges are
James Hardie building products have been tested by CSIRO in
properly supported.
accordance with AS/NZS 3837 and are classified as conforming to
Group 1 material (highest and best result possible), with an average
specific extinction area far lower than the permissible 250m2/kg, as
referenced in Specification C1.10a of the BCA.
hardiEflex sheet
Surface: flat, smooth surface, square sheet edge (bevel edge available in Queensland only)
Mass: (for 4.5mm thick) 6kg/m2 (for 6.0mm thick) 8.1kg/m2
Length (mm): Width (mm): Thickness (mm):
1800 900 4.5
1200 4.5/6.0
2100 1200 4.5
2400 900 4.5/6.0
1200 4.5/6.0
2700 900 4.5
1200 4.5/6.0
3000 900 4.5/6.0
1200 4.5/6.0
versilux lining
Surface: smooth surface, square sheet edge (bevel edge available in Queensland only)
Mass: (for 4.5mm thick) 6.2kg/m2 (for 6.0mm thick) 8.3kg/m2
Length (mm): Width (mm): Thickness (mm):
2400 900† 4.5*
1200 4.5*/6.0
2700 1200 6.0/9.0**
3000 900 6.0*†
1200 4.5*/6.0
3600 1200 4.5*/6.0
hardiEgroove lining
HardieGroove lining is a v-grooved internal
lining board with the look of timber and with
100mm the durability of fibre cement.
2.5
mm Individual batten widths are 100mm
figure 6 RAKED EAVES - PLAN figure 7 SHEET LAYOUT WITH PVC STRAIGHT JOINTS
EAVES AND SOFFITS TECHNICAL SPECIFICATION JANUARY 2012 19
figure 10 ARRANGEMENT AT LARGE OPENING
figure 16 NON-SET JOINTED SOCKET - TOP HAT SYSTEM JOINT figure 18 BULKHEAD WITH RAKING TRANSITION
figure 17 SET JOINTED SOFFIT OR EAVES figure 19 PVC STRAIGHT JOINT FIXED TO TIMBER FRAMING
(b) the Product is subject to natural variation in finish as part of the Disclaimer
manufacturing process. The builder/installer must ensure the Product The recommendations in James Hardie’s literature are based on good
meets aesthetic requirements before installation. Subject to the terms building practice but are not an exhaustive statement of all relevant
of this warranty, after installation of the Product, James Hardie is not information and are subject to conditions (d), (e), (g) and (h) above.
liable for claims arising from aesthetic surface variations if such Further, as the successful performance of the relevant system depends
variations were, or would upon reasonable inspection have been, on numerous factors outside the control of James Hardie (e.g. quality
apparent prior to installation; of workmanship and design), James Hardie shall not be liable for the
recommendations in that literature and the performance of the relevant
(c) this warranty cannot be relied upon by any other person and is not system, including its suitability for any purpose or ability to satisfy the
transferable; relevant provisions of the Building Code of Australia, regulations and
(d) the Product must be installed and maintained strictly in accordance standards.
with the relevant James Hardie literature current at the time of Important Note
installation and must be installed in conjunction with the components If you acquire goods manufactured by James Hardie as a consumer
or products specified in the literature. To obtain copies of such according to the Australian Consumer Law, our goods come with
literature go to or contact Ask James Hardie™ on 13 11 03. guarantees that cannot be excluded under the Australian Consumer
Further, all other products, including coating and jointing systems, Law. You are entitled to a replacement or refund for a major failure and
applied to or used in conjunction with the Product must be compensation for any other reasonably foreseeable loss or damage. You
applied or installed and maintained strictly in accordance with the are also entitled to have the goods repaired or replaced if the goods fail to
relevant manufacturer’s instructions and good trade practice; be of acceptable quality and the failure does not amount to a major failure.
(e) the project must be designed and constructed in strict compliance Any rights a consumer may have under this warranty are in addition to other
with all relevant provisions of the current Building Code of Australia, rights and remedies of a consumer under a law in relation to the goods
regulations and standards; to which this warranty relates. Nothing in this document shall exclude
(f) if the claimant chooses to rely upon this warranty then the claimant’s or modify any legal rights a customer may have under the Australian
sole remedy under this warranty for breach of this warranty is (at Consumer Law or otherwise which cannot be excluded or modified at law.
James Hardie’s option) that James Hardie will either supply Contact details if you wish to make a claim under this warranty: For more
replacement Product, rectify the affected Product or pay for the cost information or to make a claim under this warranty please Ask James
of the replacement or rectification of the affected Product; Hardie™ on 13 11 03, visit www.jameshardie.com.au or www.accel.com.au,
(g) In the circumstances where the Australian Consumer Law does not email James Hardie via our website or write to James Hardie at:
apply in respect of the purchase of the Product, James Hardie James Hardie Australia Pty Ltd
will not be liable for any losses or damages (whether direct 10 Colquhoun Street Rosehill NSW 2142
or indirect) including property damage or personal injury, PO Box 70 Parramatta NSW 2124
consequential loss, economic loss or loss of profits, arising in contract © Copyright 2012 James Hardie Australia Pty Ltd. ABN 12 084 635 558. ™ and ®
or negligence or howsoever arising. Without limiting the foregoing, denotes a trademark or registered mark owned by James Hardie Technology Limited
James Hardie will not be liable for any claims, damages or defects