NEUTRIK AG
AUDIOGRAPH 3300
PRELIMINARY OWNERS MANUAL
AUDIO ANALYZER 3337
ieee
NEUTRIK AG, FICONTENTS,
General
Introduction
1 Front panel controls
First use
Basic use
a Classification of controls
Operation of the basic functions
al Oscillator functions
Ll Input using the softwheel
22 Measurement functions
5 Frequency response recording
Menu orientated presetting
Front panel with controls numbered
Controls
Oscillator functions
1 Alt Steps mode
2 Oscillator termination
Measurement functions / Filters
1 Measurement input/functions
2 Filters
3 Registration paper
4 Measurement ranges
5 Definition of own measurement ranges
(Paper scale)
3.2.2.6 Measurement displays, bargraph
3.2.3 Sweep functions and definition
3.2.3.1 Standard sweeps
3.2.4 User defined sweeps (user 1-3)
3.2.461 Continuous sweep
3.2.4.2 Table sweep
3.2.5 Front panel saving (setup)
3.2.5.1 Storage, recall
3.2.5.2 Sequential runs of setup programmes
3.2.5.3 Checking setups using the softwheel
3.2.5. Tolerance analysis of sequential programmes
Menu structure, operational control
4 Menu overview (tree structure)
4.2 Self calibration - (autocal)
4.3 Reset
44 Adjustments
45 Error messages
Application examples
5. Asymmetrical wiring
5.2 Frequency response of an audio transformer
Specifications
6.1 Oscillator section
6.2 Analyzer sectionGENERAL
ANALYZER ,3337
The Audiograph Analyzer 3337 is a further component of the Neutrik 3300 system. Together
with the Power Module 3305 it forms a complete audio analyzer-oscillator system and when
used in conjunction with the Mainframe 3302 the analyzer system produces instant hard
copy print outs of the equipment or circuits under test.
The following measurement and oscillator functions can be performed quickly and accurately.
-level
frequency
-distortion (K2...K5, THD+N)
-level ratio
gain
-intermodulation
analysed as a function of frequency or level
ne low distortion oscillator provides sine-wave, square as well as IMD and DFD test signals.
The measuring range of the balanced input is selected automatically.
All measurement and oscillator functions are processor controlled and can be selected directly
by the press of a button, The measurement values are converted into the required units
or ratios.
They are portrayed digitally or, if required, analogically on an alphanumeric display.
The 3302 writing functions are also controlled by the analyzer. The frequency as well as
amplitude runs can be freely selected by the user and set accordingly. Once a setting has
been determined it can be stored - (Setup). All data is preserved when the unit is switched
off and is instantly recallable when switched on.
When the unit is switched on a functional (self) test is automatically carried out.
About the manual: text which is printed in italics refers to the analyzer controls. (numbers
indicated in brackets are identical to the front panel decription as in point 3.1)
ice the existing unit is software controlled, alterations can be easily enacted at any time.
lease inform us if you have any complaints or suggestions to make about the unit or the
manual. :
If an addition is made to the operational systems then you will of course be provided with
a new programme in the form of "Eproms".