ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
ASHRAE , EUROVENT and other regulatory organizations are EC motors replace the rotor winding with permanent magnets and EASE OF INSTALLATION are both delete options allowing the contractor to match YECAM
actively addressing indoor air quality and energy efficiency by incorporate commutation circuitry. The magnets boost the efficiency, with customized filtration or mixing plenum specifications.
setting performance standards for Air Handling Units. whilst electronic commutation eliminates the mechanical wear of YECAM Provides Engineered Lifting Lugs for Ease
carbon brushes. Using permanent magnets in the rotor eliminates and Safety of Lifting
Integrated Electronics Provide Ease of Power
The European Union has undertaken to reduce CO2 emissions by both rotor copper losses and rotor slip losses, as there is no induction and Control Connection
adopting the ErP (energy related products) directive identifying process required. This results in increased efficiency.
minimum efficieny limits for fans regardless of whether they Completely integrated electronics
operate as individual units or as components in a device or system. + softstart + high efficiency + low noise + comfortable control + integrated assembly +
Each integrated plug fan, EC motor, and variable speed drive
are supplied as a single integrated assembly. The direct drive
Both the fan and motor are impacted. This includes external rotor Benefits:
design eliminates belt drive losses and minimizes bearing losses.
designs where fan and motor come as a complete assembly as
The fan impeller is directly mounted onto the motor rotor. The YECAM is Completely Packaged • No cabinet space required
well as separate impeller and motor combinations. The YECAM The YECAM is an integrated packaged design that is complete and • No shielded wires
high efficiency permanent magnet motor and variable speed
range or Air Handling Units has been designed to exceed the includes discharge plenum, fan section, coil section, filter section • PI controller
drive are designed as matched components. This eliminates the • Easy wiring
stringent ErP 2015 minimum efficiency levels. and mixing box section.
ineffieicncies (and compensation factor) when combining multiple
3-ph
separate components from different vendors. power &
Air Handling Unit efficiency levels are determined by fan air power This makes installation easy and cost effective. Eliminating the GND
(output) divided by drive electrical power (input) and includes the need for custom fabrication and onsite labor. Relay output
AS fans in variable volume air conditioning systems spend signals
following loss factors
considerable run hours at part load operation, corresponding to
• Impeller and Casing aerodynamic losses (heat) Fliter frames are a standard inclusion. The discharge plenum is
reduced airflows and static pressures, the YECAM Air Handling unit EASE OF SERVICE
• Bearing losses (heat) designed to allow the installing contractor flexibility of choice as to
can deliver typical energy savings of up to 20% when compared to
• Belt losses (heat) discharge opening size, location and quantity. Large wide access doors permit ease of access to serviceable
today’s conventional and non-optimized induction motor, belt and
• Motor losses (heat) areas for fan/motor inspection, filter replacement, and drain tray
pulley driven fan, and 3rd party supplied VSD technologies.
• Variable speed drive losses (heat) Alternately, a standard sized and located discharge outlet can be inspection and coil cleaning.
factory provided, either on the front or top, with trimmed cutout • Doors open outward for mixing
Calculation of the efficiency of a driven fan system is defined TYPICAL INTEGRATED EC FAN/MOTOR or with flange. box and coil section access.
within AS/NZS ISO 12759, Section B, and is the product of the ASSEMBLY USED IN YECAM
efficiencies of the component parts: • The door opens inward to the
The mixing box is designed to allow the installing contractor fan discharge plenum which is
Complete drive assembly = single source
ηe = ηr = ηm *ηT *ηc *cm *cc ✓ Compact
flexibility of choice as to air inlet size and location for both O/A positively pressurized.
✓ Fully integrated system and R/A. • Doors are fitted with external
ηe is overall efficiency [%] ✓ Exceptional levels of balance lockable handles for added safety
ηr is optimal fan impeller efficiency according to P ( ) / Pa , as given in ISO 5801 [%] ✓ Extremely low levels of vibration Alternately, a standard sized and located air inlet can be factory and security.
ηm is motor efficiency [%]
u s
✓ High Efficiency provided, either on the front, top, or both, with trimmed cutout
ηT is drive mechanism (transmission) efficiency [%]
ηc is the variable speed drive efficiency [%] or inclusive of manual or motorized high grade gasketed aluminium
cm is the compensation factor to account for matching components: cm = 0.9 EC external rotor motor damper assembly. On some models an The suction side of the EC plug fans
cc is the part load compensation factor Fully featured version are fitted with protective guards.
(defined in Section 6.3 in AS/NZS ISO 12759) optional side air inlet
Flange for impeller This ensures worker safety when in
Inverter drive: Rotor shell
can be provided. the coil/drain tray service area.
The YECAM range of Air Handling Units incorporate and array • Line-side filters Permanent magnets
of high efficiency direct drive backward curved plug fans • AC-to-DC conversion Flexibility is assured NOTE : Access doors are provided on the same side as unit coil handing. Opposite side
• Process controller
incorporating advanced EC motor technology. Internal shaft
as the mixing box doors can be provided as an option.
• Overload protection
• Load-side filters Ball bearings (2x) only, or mixing box Optional lights and switches.
In the HVAC industry, the term ”EC motor“ is commonly • Customer interface Armature: and filter section, An internal 240V marine type light external switch can be factory provided as an option.
Where light and switches are optioned, one light and switch set is provided to each section
understood to mean a specific type of motor, which many • Weatherized design • Stator Lamination stack
(3 IN TOTAL)
• Magnet wire windings
associate with compact construction and high efficiency.
4 5
ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
Johnson Controls YORK® YECAM series air handling unit is typically applied to a central air-conditioning system. They have been DISTINGUISHING THE UNIT HAND CALCULATION OF THE OVERALL DIMENSION
designed incorporating variable speed EC motor technology to meet the needs of today’s sustainable building designs and to
exceed the stringent European ErP 2015 energy standard.
1. Module Design: 1M=95mm
The EC plug fan(s) operate with a wide RPM range, can satisfy variable airflow and pressure from a 0 - 10 vdc control signal. A
MODBUS high level data connection is provided as standard. 2. Length of the unit = Sum of lengths of all delivery sections.
Length of delivery section = length module ×95+96(mm)
They are the ideal HVAC solution for both new construction and revovation projects for commercial and clean room application: Example: Length of 28M-long delivery section
Pharmaceutical, Educational, Retail Shopping mall, Industrial processes, Data centers ,Hospitals and Health care, and commercial = 28×95 + 96 = 2756 (mm)
office buildings etc.
YECAM air handling units are available in 13 models with integral EC fan(s) incorporate fully variable 0-10v speed control, with and The left hand is shown in the figure.
Note: YECAM model numbers are based on a 6 row cooling + 1 row heating configuration.
YECAM Unit Lengths may change for different coil row configurations.
are suitable for a wide range of chilled water and hot water flow rates, including wide delta T applications to maximize pump energy
Refer to table SECTION B LENGTH DATA FOR DIFFERENT COIL ROW COMBINATIONS
savings. YECAM air handling units are available with multiple coil options for each model. The air flow ranges from nominal 1300 L/s
to 27,000 L/s, whilst the design incorporates both standard and high external static pressure design ranges of 500 Pa and 700 Pa.
YECAM module sizes are designed for ease of containerization and shipping. Each YECAM model comprises only two (2) sections
that require joining together on the job site. This facilitates quick and easy installation.
THREE STANDARD TYPES
Horizontal Standard Unit (H1) Horizontal Standard Unit (H3)
NOMENCLATURE
H C H C
YECAM 0911 H1 L
Mixing Box + Bag Filter + Coil + EC Supply Fan + Air Outlet Coil + EC Supply Fan + Air Outlet
York EC Motor Air Handling Unit Unit Hand: Left Hand (L) or Right Hand (R)
Unit Model Code: 0911-4836 Unit Configuration: The YECAM range comes in 3 configurations. H1 is a complete
Horizontal Standard Unit (H2)
Note: 0911=09 Height Module × H1-Horizontal 1 unit comprising discharge plenum, fan section, coil section, filter
11 Width Module; H2-Horizontal 2 section, and mixing box section. With arrangement H1 only,
H3-Horizontal 3 optional factory standard size R/A and O/A openings can be
provided. Optional standard aluminium damper assemblies can
H C also be provided.
Note:
1) 4431,4436,4836 model is stacked unit by 2×2231, 2×2236,2×2436; Note: Where optional dampers are provided, due to container dimensional limitations,
2) 2262,2272,2472 model is side by side unit by 2×2231, 2×2236,2×2436; these may ship loose for jobsite installation by the mechanical contractor .
H2 is designed to be used in conjunction with field installation of non-standard
Bag Filter + Coil + EC Supply Fan + Air Outlet mixing box arrangements and sizes.
H3 is designed to be used in conjunction with field installation of non-standard
air filter requirements and mixing box arrangements and sizes.
6 7
ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
YECAM Models 0911, 0915, 1314 incorporate a single EC fan assembly. All other YECAM models include multiple EC fan assemblies YECAM Air Flow Range YECAM air handling units are sized
arranged in a fan array. on a nominal 2.0 m/s coil velocity for
Low velocity
YECAM 2018
Airflow (k, l/s) increased energy efficiency.
Fan arrays provide the following advantages. YECAM 0911
YECAM 1318
High velocity
YECAM 0915
YECAM 1314 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
Increased redundancy in the event of fan failure This considerably reduces both coil and
0911
More homogenous flow pattern through the coils and better iternal air pressure drop wern compared
flow distribution 0915
to units sized on a nominal 2.5 m/s.
Better sound spectrum that is easier to attenuate with conventional insulated ductwork 1314
Less AHU unit length and footprint than units incorporating large
YECAM 2222 YECAM 2231 1318 Reduced internal pressure drop ensures
single fan/motor designs 2018 greater external static capacity for a
given air flow.
YECAM Model
Standardization of components reduces inventory requirements, facilitates prompt 2222
identification and replacement, and provides for
2231
ease of service When air flow requirements are selected
Reduced maintenance scope and cost as components are smaller and easier to handle
2236 below the nominal 2 m/s coil velocity,
and transport in the evet relacement is required. All fans incorporate sealed for life 2436 YECAM external static capability
bearings and eliminate maintenance and alignment issues associated with belt and YECAM 2236 YECAM 2444
increases.
YECAM 2436 2444
pulley drive systems
2 x 2231
Great for retrofit applications When air flow requirements are selected
2 x 2236
Where (optional) backdraft dampers are installed, the ideal quantity of fans only above the nominal 2 m/s coil velocity,
need be enabled during after hours use, to ensure efficient operation without risk 2 x 2436
YECAM external static capability
of instability. decreases.
Note: 1) Low velocity: airflow range @ coil face velocity 1.5m/s to nominal airflow.
2) High velocity: airflow range @ nominal airflow to coil face velocity 2.5m/s.
TECHNICAL DATA
500 Pa External Static Pressure (*2) 700 Pa External Static Pressure (*2) (*3) Dimension mm (*1) Weight kg (*1)
Cooling Heating
Airflow Capacity Capacity EC Fan Design Rated Motor Total Fan Design Rated Motor Total Fan Airflow L(mm)
EfficiencyErP2015
Model (l/s) @6Rows @1Row Quantity Input Motor Full Load Sound Input Motor EfficiencyErP2015 Full Load Sound Model (l/s) H(mm) W(mm) H1 H2 H3
Act./Tar. Act./Tar.
kW kW Power Power Amps Power Power Power Amps Power H1 H2 H3
(%) (%)
kW kW (ea) @400V dB(A) kW kW (ea) @400V dB(A)
YECAM0911 1300 31.0 18.9 1 1.5 2.6 69 / 62 4.0 79 2.0 2.6 69 / 62 4.0 83 YECAM0911 1300 1,051 1,141 3,707 3,042 2,567 678 590 533
YECAM0915 1900 48.9 29.2 1 2.2 2.6 69 / 62 4.0 82 2.8 3.8 69.7 / 62 5.8 87 YECAM0915 1900 1,051 1,521 3,707 3,042 2,567 824 709 636
YECAM1314 2500 64.6 39.0 1 2.6 2.9 72.2 / 62 4.4 80 3.6 3.81 69.7 / 62 5.8 89 YECAM1314 2500 1,431 1,426 3,707 3,042 2,567 964 815 747
YECAM1318 3500 87.7 55.1 2 4.0 2.6 69 / 62 8.0 84 5.1 2.6 69 / 62 8.0 86 YECAM1318 3500 1,431 1,806 3,707 3,042 2,567 1148 992 900
YECAM2018 5000 126.7 78.0 2 5.2 2.9 72.2 / 62 8.9 83 7.2 3.81 69.7 / 62 11.6 92 YECAM2018 5000 2,096 1,806 3,897 3,232 2,852 1503 1300 1182
YECAM2222 7000 183.2 115.3 3 7.3 2.9 72.2 / 62 13.3 84 10.0 3.81 69.7 / 62 17.4 93 YECAM2222 7000 2,286 2,186 3,897 3,232 2,852 1862 1628 1477 Notes:
YECAM2231 10500 257.3 165.9 4 11.1 2.9 72.2 / 62 17.7 87 14.5 3.81 69.7 / 62 23.2 95 YECAM2231 10500 2,286 3,041 3,897 3,232 2,852 2466 2143 1930 (*1). YECAM dimensions and weights are based on a 6 row
YECAM2236 12000 308.6 195.5 5 12.4 2.9 72.2 / 62 22.2 87 17.1 3.81 69.7 / 62 29.0 96 YECAM2236 12000 2,286 3,516 3,897 3,232 2,852 2862 2499 2255 cooling + 1 row heating configuration.
YECAM2436 13500 343.2 217.0 5 14.4 2.9 72.2 / 62 22.2 88 17.9 3.81 69.7 / 62 29.0 97 YECAM2436 13500 2,476 3,516 3,897 3,232 2,852 2976 2597 2348 YECAM Unit dimensions and weights may vary for
different coil specifications.
YECAM2444 17500 381.0 278.6 7 18.3 2.9 72.2 / 62 31.0 89 25.2 3.81 69.7 / 62 40.6 98 YECAM2444 17500 2,476 4,276 3,897 3,232 2,852 3578 3197 2848
(*2). Internal losses include for cooling coil, heating coil,
YECAM2262 21000 514.5 331.8 8 22.1 2.9 72.2 / 62 35.4 90 28.9 3.81 69.7 / 62 46.4 98 YECAM2262 21000 2,286 2 x 3,041 3,897 3,232 2,852 4932 4286 3860
fan guard, and fan inlet losses.
YECAM2272 24000 617.2 391.0 10 24.7 2.9 72.2 / 62 44.3 90 34.1 3.81 69.7 / 62 58.0 99 YECAM2272 24000 2,286 2 x 3,516 3,897 3,232 2,852 5724 4998 4510
External static pressure to include for losses associated
YECAM2472 27000 686.4 434.0 10 28.7 2.9 72.2 / 62 44.3 91 35.7 3.81 69.7 / 62 58.0 100 YECAM2472 27000 2,476 2 x 3,516 3,897 3,232 2,852 5952 5194 4696 with air filters,dampers, plenums, and the external
YECAM4431 21000 514.5 331.8 8 22.1 2.9 72.2 / 62 35.44 90 28.9 3.81 69.7 / 62 46.4 98 YECAM4431 21000 2 x 2,286 3,041 3,897 3,232 2,852 4932 4286 3860 ductwork system.
YECAM4436 24000 617.2 391.0 10 24.7 2.9 72.2 / 62 44.30 90 34.1 3.81 69.7 / 62 58.0 99 YECAM4436 24000 2 x 2,286 3,516 3,897 3,232 2,852 5724 4998 4510 (*3). For High pressure fan & motor, the actual ESP is 650Pa
for unit 2231/ 2262/4431 and 610Pa for
YECAM4836 27000 686.4 434.0 10 28.7 2.9 72.2 / 62 44.30 91 35.7 3.81 69.7 / 62 58.0 100 YECAM4836 27000 2 x 2,476 3,516 3,897 3,232 2,852 5952 5194 4696 unit 2436/ 2472/4836.
8 9
ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
Technical Specifications
INDIVIDUAL SECTION WEIGHT AND LENGTH DATA COOLING COIL PERFORMANCE DATA
Section A (H1/H2/H3) Section B Return Air Condition Mixing Air Condition Fresh Air Condition
Section Section
Model H W L mm Wt (H1) L mm Wt (H2) L mm Wt (H3) Airflow Rows Water Water Air Water Air Water Air
mm mm L mm Wt kg Qty Qty Model Total Sensible Total Sensible Water Total Sensible Water
(H1) kg (H2) kg (H3) kg (l/s) Flow Pressure Pressure Capacity Pressure Pressure Capacity Pressure Pressure
Capacity Capacity Capacity Flow Capacity Flow
Rate Drop Drop Drop Drop Drop Drop
kW kW kW kW Rate L/s kW kW Rate L/s
YECAM0911 1051 1141 1806 325 1 1901 353 1236 265 761 208 1 L/s kPa Pa kPa Pa kPa Pa
YECAM0915 1051 1521 1806 387 1 1901 437 1236 322 761 249 1 YECAM0911 1300 6 21.9 17.3 0.74 8.1 131 31.0 23.37 1.1 14.3 137 49.9 32.60 1.7 10.8 147
YECAM1314 1431 1426 1806 448 1 1901 516 1236 367 761 299 1 YECAM0915 1900 6 36.5 27.2 1.24 24.2 138 48.9 35.67 1.7 37.3 140 79.3 49.90 2.7 28.5 154
YECAM1318 1431 1806 1806 549 1 1901 599 1236 443 761 351 1 YECAM1314 2500 6 47.5 35.7 1.62 17.9 125 64.6 47.12 2.2 28.3 131 103.7 65.90 3.5 23.5 141
Discharge plenum, fan section and YECAM1318 3500 6 63.6 48.6 2.18 12.9 131 87.7 64.72 3.0 22.6 137 143.1 91.50 4.9 23.8 150
YECAM2018 2096 1806 1996 722 1 1901 781 1236 578 856 460 1
coil plenum (section A)
YECAM2222 2286 2186 1996 886 1 1901 976 1236 742 856 591 1 YECAM2018 5000 6 91.6 69.9 3.13 11.7 122 126.7 93.17 4.3 20.9 128 207.6 132.10 7.1 22.7 138
YECAM2231 2286 3041 1996 1117 1 1901 1349 1236 1026 856 813 1 YECAM2222 7000 6 137.0 101.7 4.66 23.2 125 183.2 133.04 6.2 37.2 128 298.2 188.30 10.2 41.3 145
YECAM2236 2286 3516 1996 1305 1 1901 1557 1236 1194 856 950 1 YECAM2231 10500 6 207.1 153.0 7.04 29.5 132 257.3 191.94 8.7 15.4 131 440.5 279.20 14.9 41.0 148
YECAM2436 2476 3516 1996 1347 1 1901 1629 1236 1250 856 1001 1 YECAM2236 12000 6 225.3 170.1 7.67 13.6 122 308.6 225.78 10.6 25.1 128 516.7 325.30 17.6 62.9 145
YECAM2444 2476 4276 1996 1600 1 1901 1978 1236 1597 856 1248 1 YECAM2436 13500 6 252.9 191.0 8.66 14.7 128 343.2 252.07 11.6 25.8 131 576.8 363.80 19.6 66.5 151
YECAM2262 2286 3041 1996 1117 2 1901 1349 1236 1026 856 813 2 YECAM2444 17500 6 375.0 287.0 12.70 25.0 123 375.0 287.00 12.7 25.0 123 375.0 287.00 12.7 25.0 123
YECAM2272 2286 3516 1996 1305 2 1901 1557 1236 1194 856 950 2 YECAM2262 21000 6 414.2 306.0 14.08 29.5 132 514.5 383.88 17.4 15.4 131 881.0 558.40 29.8 41.0 148
YECAM2472 2476 3516 1996 1347 2 1901 1629 1236 1250 856 1001 2 YECAM2272 24000 6 450.6 340.2 15.34 13.6 122 617.2 451.56 21.1 25.1 128 1033.4 650.60 35.2 62.9 145
YECAM4431 2286 3041 1996 1117 2 1901 1349 1236 1026 856 813 2 YECAM2472 27000 6 505.8 382.0 17.32 14.7 128 686.4 504.14 23.2 25.8 131 1153.6 727.60 39.2 66.5 151
Coil section, filter section, and YECAM4431 21000 6 414.2 306.0 14.08 29.5 132 514.5 383.88 17.4 15.4 131 881.0 558.40 29.8 41.0 148
YECAM4436 2286 3516 1996 1305 2 1901 1557 1236 1194 856 950 2
mixing box plenum sections
YECAM4836 2476 3516 1996 1347 2 1901 1629 1236 1250 856 1001 2 (section B) YECAM4436 24000 6 450.6 340.2 15.34 13.6 122 617.2 451.56 21.1 25.1 128 1033.4 650.60 35.2 62.9 145
YECAM4836 27000 6 505.8 382.0 17.32 14.7 128 686.4 504.14 23.2 25.8 131 1153.6 727.60 39.2 66.5 151
Note: Published nominal data based on 500 pa ESP fans and 6 row cooling + 1 row heating coils (6+1)
YECAM4436 24000 1 346.2 4.24 4.2 11 391.0 4.80 5.3 11 8. The weight listed in the table is the shipping weight. The
Note: Section A includes discharge plenum, fan section, and coil access plenum. Note: Maximum weight based on 700 pa ESP fans and 10 + 4 row coils. operation weight of unit is about 20% more than the
YECAM4836 27000 1 384.2 4.70 4.4 13 434.0 4.80 5.6 13 shipping weight.
Note: Section B includes coil section, filter section, and mixing box plenum. For specific unit dimensions and weights refer to the manufacturer’s selection
software performance report.
10 11
ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
12 13
ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
Acoustics Dimension data with discharge plenum and mixing box options
FAN ARRAY SOUND POWER LEVEL-PRESSURE SIDE,ESP 500 Pa HORIZONTAL STANDARD UNIT (H1)
Air Flow Fan W H L L1
Model ESP(Pa) 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz LwA mm mm mm mm
Front MB / Rear AO Top MB / Side MB Top AO
(L/S) Quantity Model Airflow
YECAM 0911 500 1,300 1 73.6 73.6 76.8 76.5 75.8 70.9 64.5 59.5 79.4 (l/s) I J K L
A B C D E F G H M N O P
YECAM 0915 500 1,900 1 73.1 71.5 76.0 78.4 78.6 74.0 68.3 63.8 81.9 Top Side Top Side Top Side Top Side
YECAM 1314 500 2,500 1 67.9 72.2 73.0 75.2 77.2 71.6 67.6 64.8 80.0 YECAM0911 1300 1141 1051 3707 1806 580 580 280.5 285.5 580 580 390 485 138 138 280.5 137.5 580 390 280.5 138
YECAM 1318 500 3,500 2 74.9 73.8 78.2 80.4 80.7 76.2 70.4 65.7 84.0 YECAM0915 1900 1521 1051 3707 1806 580 770 375.5 285.5 770 580 485 485 138 138 375.5 137.5 770 485 375.5 138
YECAM 2018 500 5,000 2 71.3 75.9 76.5 78.7 80.6 74.9 70.9 68.0 83.4 YECAM1314 2500 1426 1431 3707 1806 580 770 328 475.5 770 960 485 485 138 138 328 137.5 770 485 328 138
YECAM 2222 500 7,000 3 73.1 76.6 77.6 79.6 81.4 75.7 71.5 68.3 84.2 YECAM1318 3500 1806 1431 3707 1806 580 1150 328 475.5 1150 960 485 485 138 138 328 137.5 1150 485 328 138
YECAM2018 5000 1806 2096 3897 1996 770 1150 328 713 1530 1720 485 485 138 138 138 90 1530 580 138 138
YECAM 2231 500 10,500 4 74.2 79.8 80.2 82.4 84.1 78.4 74.6 71.9 87.0
YECAM2222 7000 2186 2286 3897 1996 960 1340 423 713 1910 1910 485 485 138 138 138 90 1910 580 138 138
YECAM 2236 500 12,000 5 75.5 79.4 80.3 82.4 84.2 78.5 74.4 71.3 87.0
YECAM2231 10500 3041 2286 3897 1996 1150 1720 660.5 618 2765 1815 485 485 138 138 138 137.5 2670 580 185.5 138
YECAM 2436 500 13,500 5 75.0 81.3 81.5 83.7 85.4 79.8 76.0 73.3 88.3
YECAM2236 12000 3516 2286 3897 1996 1340 1720 898 523 3240 1815 485 485 138 138 138 137.5 3240 580 138 138
YECAM 2444 500 17,500 7 76.6 81.1 81.9 84.0 86.0 80.3 76.3 73.4 88.8
YECAM2436 13500 3516 2476 3897 1996 1340 1910 803 618 3240 1815 485 485 138 138 138 232.5 3240 580 138 138
YECAM 2262
500 21,000 8 77.2 82.8 83.2 85.4 87.1 81.4 77.6 74.9 90.0 YECAM2444 17500 4276 2476 3897 1996 1340 2670 803 618 3240 - 485 - 138 - 518 - 3240 580 518 138
YECAM 4431
YECAM2262 21000 6082 2286 3897 1996 1150 1720 660.5 618 2765 - 485 - 138 - 138 - 2670 580 185.5 138
YECAM 2272
500 24,000 10 78.5 82.4 83.3 85.4 87.2 81.5 77.4 74.3 90.0 YECAM2272 24000 7032 2286 3897 1996 1340 1720 898 523 3240 - 485 - 138 - 138 - 3240 580 138 138
YECAM 4436
YECAM 2472 YECAM2472 27000 7032 2476 3897 1996 1340 1910 803 618 3240 - 485 - 138 - 138 - 3240 580 138 138
500 27,000 10 78.0 84.3 84.5 86.7 88.4 82.8 79.0 76.3 91.3 YECAM4431 21000 3041 4572 3897 1996 1150 1720 660.5 618 - 1815 - 485 - 138 - 137.5 - - - -
YECAM 4836
YECAM4436 24000 3516 4572 3897 1996 1340 1720 898 523 - 1815 - 485 - 138 - 137.5 - - - -
Note: Fan array sound data is extrapolated from EBM fan sound data.
YECAM4836 27000 3516 4952 3897 1996 1340 1910 803 618 - 1815 - 485 - 138 - 232.5 - - - -
FAN ARRAY SOUND POWER LEVEL-PRESSURE SIDE,ESP 700 Pa Front MB = mixing box front air inlet Rear AO = discharge plenum horizontal supply air outlet Top MB = mixing box top air inlet
Side MB = mixing box side air inlet Top AO = discharge plenum vertical supply air outlet
Air Flow Fan
Model ESP(Pa) 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz LwA
(L/S) Quantity Horizontal unit YECAM0911-2444 Side by side unit YECAM2262-2472 Stacked unit YECAM4432-4836
YECAM 0911 700 1300 1 78.0 79.5 83.5 80.5 78.9 73.7 67.7 64.0 83.1 P N J K
L
YECAM 0915 700 1900 1 74.7 81.5 81.8 81.5 83.1 80.6 76.6 72.4 87.1 P N J K
H C
YECAM 1314 700 2500 1 73.3 75.5 81.7 84.0 85.0 82.8 79.3 75.3 89.2 H C
E
I
E
YECAM 1318 700 3500 2 77.3 76.6 80.4 82.4 82.5 78.1 72.5 68.1 85.9
E
H C
B
H C
H C
100
YECAM 2018 700 5000 2 76.3 78.5 84.7 87.0 88.0 85.8 82.3 78.3 92.2
H
E
H
B
100
H
H
B
H C
YECAM 2222 700 7000 3 78.5 81.6 86.7 87.8 88.9 86.7 83.3 79.2 93.2 D
100
H
H
YECAM 2231 650 10500 4 79.1 80.8 86.9 89.8 90.8 88.7 85.1 81.6 95.1 D
E
I
YECAM 2236 700 12000 5 80.5 83.2 88.8 90.3 91.4 89.2 85.8 81.7 95.7
G
G
YECAM 2436 610 13500 5 80.2 81.9 88.1 91.5 92.4 90.4 86.6 83.3 96.7
100
H
H
O
L
D
YECAM 2444 700 17500 7 81.8 84.0 90.2 92.4 93.4 91.3 87.8 83.8 97.6
G
YECAM 2262
F
F
I
J K
650 21,000 8 82.1 83.8 89.9 92.8 93.8 91.7 88.1 84.6 98.1
YECAM 4431
A
F
F
G
G
YECAM 2272
700 24,000 10 83.5 86.2 91.8 93.3 94.4 92.2 88.8 84.7 98.7
YECAM 4436
A
G
G
YECAM 2472
A
F
F
610 27,000 10 83.2 84.9 91.1 94.5 95.4 93.4 89.6 86.3 99.7 C
YECAM 4836
F
F
I
Note: Fan array sound data for multiple fan units is extrapolated from EBM single fan published sound data.
Note: Dimension based on the standard unit with 6 row cooling C
and 1 row heating coil.
Coil segment length may vary with the coil rows and coil selection.
L
C
14 15
ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
Dimension data with discharge plenum options Dimension data with discharge plenum options
Rear AO = discharge plenum horizontal supply air outlet Top AO = discharge plenum vertical supply air outlet Rear AO = discharge plenum horizontal supply air outlet Top AO = discharge plenum vertical supply air outlet
Horizontal unit YECAM0911-2444 Side by side unit YECAM2262-2472 Stacked unit YECAM4432-4836 Horizontal unit YECAM0911-2444 Side by side unit YECAM2262-2472 Stacked unit YECAM4432-4836
P N P N
P N
H C H C P N H C
H C
E
H C
E
B
E
H C H C H C H C
E
H C
100
100
H
100
H
H
H C
100
H
D D
B
H C
100
B
H
100
D H C
H
H C
D
O
E
H C
G
G
O
H C
100
H
100
O
G
H
D
D
G
M
M
F
F
M
A
F
A
F
G
G
A
A
G
G
C
A
F
A
F
C
M
F
M
F
C
C
Note: Dimension based on the standard unit with 6 row cooling and Note: Dimension based on the standard unit with 6 row cooling and
O
O
C C
1 row heating coil. 1 row heating coil.
Coil segment length may vary with the coil rows and coil selection. Coil segment length may vary with the coil rows and coil selection.
16 17
ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
EC FAN MOTOR TERMINAL LAYOUT The air handling units shall be YORK suitable lifting points to permit safe The casing frame shall consist of
YECAM manufactured by Johnson lifting and installation. Each section shall aluminium penta-post construction with
Connection screen Optional single point power connection with Controls complete with direct drive have a minimum of four (4) lifting points. composite tri-axial angle lugs, and nylon
circuit breakers EC motor fan technology with integral Lifting points shall be designed to accept insulation strips, and shall be cold bridge
1 L1 variable speed drives. standard certified container lifting lugs. free complete with thermal break.
KL 1 2 L2
3 L3 Units shall be supplied complete The installing contractor is responsible The casing shall be extremely rigid to
comprising:- for providing the container lifting lugs meet the high EN 1886:2008 standards
PE PE • Discharge supply air plenum with and specialist rigging services. Where of casing performance. Air leakage
hinged access door more than 4 lifting points are provided, shall be virtually eliminated by double
1 RSA Din 1 5
lifting points on adjacent faces shall be gasketed doors, high strength panels,
2 RSB +10 V 6 • Fan section with EC direct drive
KL 2 removed by the mechanical contractor, and door locking mechanisms. AHU
3 GND Ain 1 U 7 plenum (plug) fan or multiple fan array.
after lifting into position, and prior to sections that ship separately shall be
4 C NC 8 joining the sections together. fully gasketed at the joint and clamped
• Coil section with cooling & heating coil
with hinged access door together with easy to install fasteners.
Units shall be installed on a suitable level
Power Option with circuit breakers Single point power option
• Filter section with filter frame array concrete plinth or steel structure. Rubber Sections shall be joined together on site
isolation pads shall be provided and by the mechanical contractor using the
• Return air plenum (mixing box) with
No. Conn. Designation Function / assignment installed by the mechanical contractor joining connectors provided. Units with
hinged access door.
KL 1 1 L1 Mains supply connection, supply voltage 3~380 - 480 VAC; 50/60 Hz prior to placing the units into position. a casing height of < 1.3 m shall have
KL 1 2 L2 Mains supply connection, supply voltage 3~380 - 480 VAC; 50/60 Hz external joiners. Units with a casing
Units shall be installed in strict Units shall be properly levelled by the height > 1.3 m shall have internal joiners.
KL 1 3 L3 Mains supply connection, supply voltage 3~380 - 480 VAC; 50/60 Hz
accordance with the manufacturers mechanical contractor when in position
PE PE Earth connection, PE connection
Installation, Operation and Maintenance using additional isolation pads and shims The casing design shall meet European
KL 2 1 RSA Bus connection RS-485, RSA MODBUS RTU; SELV manual (IOM). standard EN 1886:2008.
where necessary.
KL 2 2 RSB Bus connection RS-485, RSB MODBUS RTU; SELV
KL 2 3 GND Signal ground for control interface; SELV Units shall be shipped with a protective Unit panels shall be 50mm thick and Specification shall be as follows:-
KL 2 4 C Status relay; floating status contact; changeover contact; common connection; plastic wrapping to protect the unit from of double wall construction. Inner and
contact rating 250 VAC / 2 A (AC1) the elements and ingress of debris. Each outer sheets shall be 0.6mm (0.8mm • Casing Strength: D1
KL 2 5 Din 1 Digital input 1 enabling of electronics, section shall ship with an identification is an option) galvanized steel (white • Casing Air leakage: L1
Enabling: open pin or applied voltage 5-50 VDC nameplate clearly identifying the project painted galvanized steel in is an option) • Filter Bypass Leakage: F9
Disabling: bridge to GND or applied voltage <1 VDC reference, unit reference, electrical to facilitate ease of cleaning both • Thermal Bridging: TB2
Reset funtion: triggers software reset after a level change to <1 V; SELV nameplate data, and matching section internally and externally. Insulating foam • Thermal Transmittance: T2
KL 2 6 +10 V Fixed voltage output 10 VDC, ±3%, max. 10 mA, short-circuit-proof, identification. shall be “0” ODP type polyurethane of
density 45kg/m3 and providing a thermal All cooling coil sections shall be provided
power supply of external devices (e.g. potentiometer), SELV
Units shall be supplied in two (2) sections conductivity coefficient lower than with an externally insulated drain
KL 2 7 Ain 1 U Analogue input 1 (set value) 0-10 V, Ri = 100 KΩ, parametrisable curve, only usable
with integral base frames designed with 0.02W/m·K. pan made of stainless steel. Where
as alternative to input Ain 1 ı SELV
KL 2 8 NC Status relay, floating status contact; break for failure
18 19
ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
multiple coils are stacked vertically, an connector stub to facilitate ease of The light switches shall be located on protection and safety devices. (Where A filter section shall be factory provided As a factory supplied option, a standard
intermediate drain tray made of stainless installing control valves and connecting the unit handing side. multiple EC motors are incorporated and shall include an array of galvanized sized supply air opening can be provided
steel shall be provided. piping. into a fan array, an optional single point filter frames using a maximum of four in the discharge plenum. As a factory
Fans shall be IP54 integral EC motor power connection shall be provided). (4) industry standard filter sizes. Filter supplied option, a standard sized return
Coils shall be installed such that the coil Hinged access doors shall be of 50mm direct drive, backward curved, single The single point power junction box frames are designed to accept 305mm air and a standard sized outside air
headers are enclosed by the unit casing, double wall construction similar to the inlet type selected for stable operation shall include a 415v circuit breaker for deep bag filters as standard or 305mm opening can be provided. Optional
and all condensate is removed by the casing panels. Double gaskets shall and optimum energy efficiency in each fan motor and a common earth bar. deep bag filters with a 50 mm pleated factory provided standard sized openings
primary drain pan. Where stacked coils be provided around the full perimeter accordance with the scheduled Optional factory power wiring from the panel pre-filter as an option. The filter shall be trimmed and capped to prevent
are provided, the intermediate drain tray of the doors to prevent air leakage. performance requirements. Combined EC single point power junction box to the section shall be designed to accept any exposed insulation and panel edges.
outlet shall be factory piped into the Access doors shall have a minimum of fan & motor efficiency shall comply with multiple fan motors shall be internally filters of AAF manufacture or approved
primary drain pan. two (2) lockable handles. (Access doors European efficiency directive ERP 2015. run via factory provided metal cable equal. Filters shall be provided and For the optional factory provided
shall be provided with optional perspex Fans shall be EBM Papst K3G series or trays. installed by the mechanical contractor. discharge opening, an optional 40mm
All drain pans shall be positively sloped viewports capable of withstanding unit approved equivalent. The array of filter frames shall include flange shall be provided.
towards the drain outlet to eliminate any operating pressures). Fans shall be provided with a powder the necessary mounting clips and shall
stagnant water pooling. Fans shall be statically and dynamically coated galvanized steel mesh safety include block-off panels around the filter For the optional standard factory return
Access doors to fan discharge plenum balanced by the fan manufacturer. guard fitted to the suction side of array to prevent air bypass. air and outside air openings, optional
The cooling coil section shall be readily and mixing box plenum shall be 515 mm Each fan shall be a single width, single each fan. As an option, each fan can factory fitted dampers can be provided
accessed by an access door to facilitate wide to permit service personnel entry. inlet multi blade backward curved be provided with a factory installed A 665 mm deep return air plenum to control the volume of outside air and
coil cleaning and drain tray inspection. Access doors to inspect the drain pan type and be directly driven. The fan backdraft damper in lieu of a mesh (mixing box) section shall be provided return air. Optional dampers shall be of
Coil support members shall be of the and coil section shall be 515 mm wide assembly shall include an integral high guard. The backdraft damper shall close as standard and located upstream of aluminium aerofoil construction with
same material as the coil casing. for units with a casing height > 1.3 m efficiency permanent magnet electrically when the fan is disabled. the filter section complete with full size blade edge seals on all blades. Blades
high and shall be 325 mm wide for units commutated motor complete with outward opening lockable access door shall rotate on a 12.5mm diameter
Coils shall have 12mm copper tubes with a casing height < 1.3 m. control electronics and variable speed The positively pressurized fan discharge to permit entry by service personnel to shaft with sleeve bearings and shall
mechanically expanded into aluminium drive. The fan speed shall be modulated plenum shall incorporate a lockable facilitate filter replacement. be arranged in an opposed blade
fins. (Aluminium fins shall have an Each accessible section shall be fitted from a 0-10v control signal. Fans shall inward opening door that provides configuration. The drive shaft shall
optional flexible polymer hydrophilic with a marine style light. An optional also be provided with a MODBUS high service access to the fans and motors. Units shall be provided complete with extend 65mm beyond the damper frame.
coil coating for additional corrosion factory mounted marine style light level data connection providing access Access to the plenum section shall end panels with no air discharge or air
resistance). Coil frames shall be made fixture shall be provided to facilitate to scheduled fan operating parameters be restricted by the plenum internal inlet openings.The mechanical contractor [Note: Optional dampers can be manually fixed in
of galvanized steel (stainless steel maintenance and service visibility. Each by a Building Automation System. Fan pressure when the unit is operational. shall cut and trim supply air openings in position or modulated via a 24v AC actuator. All 24v
coil frames optional). Coils shall be AC damper actuators shall be provided and installed
internal light fitting shall be wired to sections containing an array of multiple A fan plenum door switch shall be the discharge plenum, and outside air
by the mechanical contractor.]
rated for 1600 kPa operating pressure an external 240v switch. The electrical fans shall be controlled from a common provided and installed by the mechanical and return air openings in the mixing box
and rated in accordance with AHRI contractor shall be responsible to control signal. The integral EC fan & contractor and electrically interlocked to plenum to suit the ductwork layout as
standard 410. Coils shall have a copper provide a 240v supply to each light motor assembly shall incorporate sealed the AHU control circuit. per the construction drawings.
header complete with a threaded brass switch in accordance with local codes. for life bearings and all necessary motor
20 21
ENERGY EFFICIENT EC MOTOR MODULAR AIR HANDLING UNITS MODEL YECAM
EC Motor AHUs
High Efficiency Chiller
EC Motor FCUs
EC Motor FCUs
Service Solutions