Sie sind auf Seite 1von 5

Mitsubishi iQ Platform-compatible October 2009 New Product Release

Graphic Operation Terminal


GOT1000 Series [GT12 Model]

GT12
Debut!

10.4 8.4
inch inch

Cost Effective Large-Size


Cost Effective Large-Size Built-in
Built-in Ethernet
Ethernet
Large-size models with built-in Ethernet
in the standard model range!
GOT1000 Comprehensive Lineup NEWmodel
GOT1000 GRAPHIC OPERATION TERMINAL

GT12
Including the new, cost-effective GT12 Series models, a total of 73 models provides the widest range of
display options for the OEM machine builder and End User facility installation.
NEW
Full-spec Model Full-spec Model Standard Model Standard Model Compact Model
With a variety of integrated Wide range of uses Standard functions with Enhanced with basic Including all the basic
functions, such as Ethernet
and multimedia
from network to stand alone built-in Ethernet functions for stand alone
application
functions required for
a HMI display
Fully integrated models
Large now released!
GT16 GT15 GT1275-VNBA GT1265-VNBA GT12 10.4 inch and
15” GT1695M-XTBA
GT1695M-XTBD
GT1595-XTBA
GT1595-XTBD
8.4 inch models
Integrated hardware and functionality is
GT1685M-STBA GT1585V-STBA
GT1685M-STBD GT1585V-STBD
now available in large-size models.
12.1”
GT1585-STBA
GT1585-STBD

GT1675M-STBA GT1575V-STBA
GT1675M-STBD
GT1675M-VTBA
GT1575V-STBD
GT1575-STBA GT1575-VNBA GT12 AC type
10.4"
AC type
10.4” Resolution: 640x480 Resolution: 640x480 8.4"
GT1675M-VTBD GT1575-STBD
GT1575-VTBA
GT1575-VNBD
GT1275-VNBA NEW Display colors: 256 colors type Display colors: 256 colors type

Stylish body
GT1572-VNBA LCD: TFT color LCD LCD: TFT color LCD
GT1575-VTBD GT1572-VNBD Safety standard : CE, UL Safety standard : CE, UL

GT1665M-STBA GT1565-VTBA Main unit External I/F Analog touch panel


8.4” GT1665M-STBD
GT1665M-VTBA
GT1565-VTBD
GT1562-VNBA
GT1265-VNBA NEW TFT Analog
256 touch
VGA 6MB USB
Ethernet RS-232 RS-422 device
CF
colors panel 640x480 memory /485 card
GT1665M-VTBD GT1562-VNBD
Screen Size

GT1555-VTBD
GT1555-QTBD GT11 GT10
GT1555-QSBD GT1155-QTBD GT1150-QLBD GT1055-QSBD
GT1550-QLBD GT1155-QTBDQ GT1150-QLBDQ GT1050-QBBD
5.7”
GT1155-QTBDA GT1150-QLBDA
GT1155-QSBD GT1155HS-QSBD
GT1155-QSBDQ GT1150HS-QLBD
GT1155-QSBDA

GT1045-QSBD
4.7” GT1040-QBBD

GT1030-LBD GT1030-LBDW
GT1030-LBD2 GT1030-LBDW2 Full flat face
GT1030-LBL GT1030-LBLW
4.5”
GT1030-LWD GT1030-LWDW
GT1030-LWD2 GT1030-LWDW2
GT1030-LWL GT1030-LWLW

GT1020-LBD GT1020-LBDW
Flexible embedded
GT1020-LBD2
GT1020-LBL
GT1020-LBDW2
GT1020-LBLW
communications
3.7” GT1020-LWD GT1020-LWDW USB device
GT1020-LWD2 GT1020-LWDW2
Small GT1020-LWL GT1020-LWLW

Multimedia Multimedia Video/RGB Video/RGB


Built-in Memory 15MB 5-9MB 6MB 3MB 512KB-3MB
Built-in Interface Ethernet USB host USB device USB device RS-232 Ethernet USB device USB device RS-232 RS-232
RS-232 RS-422/485 RS-232 RS-422/485
Built-in Interface
*Depends on the model or hardware version
Bus RS-422 RS-422/232 RS-422/485 USB device RS-422 RS-422/485
Optional Interface Bus Ethernet Bus CC-Link (via G4 only) CC-Link (via G4 only)
RS-232 RS-422 RS-422/485 RS-232 RS-422 RS-422/485
CC-Link IE CC-Link (ID station/via G4) CC-Link IE CC-Link (ID station/via G4)
MELSECNET/H MELSECNET/H
RS-232 RS-422/485 Ethernet CF card
* For more details about connnection destination of models other than the GT12 series, see "GOT1000 series catalog" <L(NA) 08054-E 0901>.
2 3
GT12, new models offer flexible configurations and GT12 provides many essential functions suited for
expandability engineered solutions
A wide range of devices can be interfaced Multi-terminal connection Useful functions of GT12
to GT12 models using
Ethernet • RS-232 • RS-422/485 n Up to two GT12 units can be connected to one PLC n Even low cost models are infused with functionality commonly found in more expensive models.
•Multi-channel function •Historical trend graph function •Recipe function (CSV, binary) •A/FX list editor
n A variety of built-in interfaces •Logging function •Backup/restore function •Advanced alarm function •System monitor function
The built-in interfaces (Ethernet, RS-422/485 and RS-232) enable
connection to up to two kinds of FA equipment simultaneously. When RS-422 is used to connect the 1st GOT ]1 n Multi-language display (excluding KANJI region settings)
n Ethernet helps extend systems
The built-in Ethernet interface connects to PLC CPUs with built-in Ethernet
and host systems easily.
Logging function/Historical trend graph
n Wide selection of connectable FA devices and peripherals FX, A, QnA
•Mitsubishi PLCs/motion controllers •Microcomputers n Logging function
RS-422 RS-232
•Mitsubishi servo amplifiers •Temperature controllers Max. 30m Max. 15m lCollecting data from temperature controllers and other units with the lCollected data can be used for archives and analytical purposes when
•Mitsubishi inverters •Barcode readers GOT can reduce the load on the PLC. being saved to a CF card.
•Mitsubishi industrial robots •RFID readers
•Mitsubishi CNCs •Third party PLCs
]:For the connectable models and connection types, refer to GOT1000
series connection manuals. PLC

Connection type to Mitsubishi PLCs/motion controllers When RS-232 is used to connect the 1st GOT ]1
: Supported -: Not supported
Connection type
CC-Link (via G4)
Computer link
connection
CPU direct
Ethernet

FX, Q Temperature controller


Mitsubishi PLCs/ RS-232 RS-422
motion controllers Max. 15m Max. 30m
MELSEC-Q series (Q mode) ]1 ]2

MELSEC-Q series (A mode) - Buffering area CF card


]1:Refer to the connection manual for applicable models, required (GOT memory)
MELSEC-QnA series - interface and compatibility with serial communication units (computer
MELSEC-A series - link units). The maximum length varies depending on the connected
equipment. Refer to the connection manual for more details.
MELSEC-FX series - - Collect device data from PLCs Save data in the buffering area Analyze data in the CF card
Motion Controller CPU (Q series) - and temperature controllers to the CF card (CSV or Unicode text files)
into the buffering area on a personal computer
Motion Controller CPU (A series) - - Coming
]1:QnUDE has a built-in Ethernet module; additional module is not required Multi-drop connection soon
]2:Excluding QnUDE
n Multiple GT12 units can be connected to one PLC unit n Historical trend graph
via the serial multi-drop connection unit. lData collected by the logging function can be displayed in a time-series lThe data collected by the logging function can be displayed in graph
Multi-channel function graph from a CF card as well as from the buffering area. form; past data can be displayed simply by touching a scroll switch.
lBy specifying a date and time, a specific time can be displayed in the
n The multi-channel function enables the connection of Serial multi-drop ]:Logging function settings are required to use historical trend graph. center of the graph.
different types of FA devices simultaneously. connection unit GOT GOT GOT
Up to 2 channels of equipment such as PLCs/servo amplifiers/inverters/ FX, A, QnA, Q
temperature controllers can be connected and monitored.

Backup/restore function
Load on the PLC can
be reduced instead of
Cable 1 Cable 2 RS-485 n Backup important sequence programs to be safe and secure in case of an emergency
all devices being
connected to the PLC. lT he sequence program and parameter data of the PLC CPU and
Same spec. motion controller can be backed up to the CF card in the GOT.
as 1:1 connection Example of use
lUsers can perform batch operation to restore the data to the PLC CPU
or motion controller. Make a data backup in preparation for PLC CPU failure or a dead
Temperature controller Expandable to up to 500m battery to quickly replace the faulty device and restore the system
(including the distance between the serial multi-drop <Applicable data> Programs, parameters, device comments, device using the backup.
connection unit [GT01-RS4-M] and the PLC) initial value data, file registers, etc.
<Applicable model> M
 ELSEC Q-Series (excluding Q12PRH/Q25PRHCPU), If data is backed up
CF card,
Q-Series motion controllers (SV13/SV22 only), etc.
MELSEC FX-Series, CNC C70

Other features <Applicable connection type> CPU direct connection,


computer link connection,
Ethernet connection (host only)
Sequence
Replace CPU program,
etc.
Restore
n USB device (Mini-B, rear face) n Ample memory capacity <Optional device> CF card
Connecting to a personal computer via USB (Mini-B) enables the transfer The GT12 has 6MB memory so users can add a variety of objects, parts,
of operating systems and project data. The FA transparent function and functions without running out of memory. CPU direct
enables modification of sequence programs. connection

n TFT LCD VGA (640x480) monitor GT12 6MB  LC CPU programs can be changed easily without a personal
P Back up
TFT LCD display provides easily-viewable screens. VGA resolution GT11 3MB computer at the worksite or any previous programming
provides satisfactory expressiveness. knowledge of GX Developer.
GT105 /GT104 3MB
n Analog touch panel GT1030 1.5MB
Objects such as push buttons and switches can be freely placed around ]:When replacing the PLC CPU, the restoration function may not be
GT1020 512KB For more details, see "GOT1000 series catalog"<L(NA) 08054-E 0901>. available depending on the system configuration and connection type.
the screen. The clear display face without grids makes it easy to
recognize pictures and characters.

4 5
Function list
GT16 GT12 GT11 l : Supported -: Not supported or not applicable GT16 GT12 GT11 l : Supported -: Not supported or not applicable
Model Model

Extended/optional function

Extended/optional function
]2

]2
GT16 GT12 GT11 GT16 GT12 GT11

OS installation

OS installation
Category

Category
Function ]1 Function ]1

required

required
GT1695M GT1685M GT1675M GT1675M GT1665M GT1665M GT1275 GT1265 GT115 GT115 GT115 GT1695M GT1685M GT1675M GT1675M GT1665M GT1665M GT1275 GT1265 GT115 GT115 GT115

devices

devices
-XTB -STB -STB -VTB -STB -VTB -VNBA -VNBA -QBD -QBD HS-QBD -XTB -STB -STB -VTB -STB -VTB -VNBA -VNBA -QBD -QBD HS-QBD

Other

Other
XGA SVGA SVGA VGA SVGA VGA VGA VGA QVGA QVGA QVGA XGA SVGA SVGA VGA SVGA VGA VGA VGA QVGA QVGA QVGA
15” 12.1” 10.4” 10.4” 8.4” 8.4” 10.4” 8.4” 5.7” 5.7” 5.7” 15” 12.1” 10.4” 10.4” 8.4” 8.4” 10.4” 8.4” 5.7” 5.7” 5.7”
Bus connection l l l l l l - - - l - Parts (object + figure) layer function l l l l l l l l l l l
CPU direct connection l l l l l l l l l - l Screen switching l l l l l l l l l l l
Computer link connection l l l l l l l l l - l Station No. switching l l l l l l l l - - -
MELSECNET/H connection l l l l l l - - - - - Multilingual support function l l l l l l l l l l l
MELSECNET/10 connection l l l l l l - - - - - Password l l l l l l l l l l l
CC-Link IE controller network connection l l l l l l - - - - - System information l l l l l l l l l l l

Common settings
Connection configuration

l l l l Connected device setting l l l l l l l l l l l


CC-Link connection (ID station/via G4) l l l l l l -
Via G4 only Via G4 only Via G4 only Via G4 only Boot logo l l l l l l l l l l l
Ethernet connection l l l l l l l l - - - Comment registration l l l l l l l l l l l
Third party PLC connection l l l l l l l l l - l Parts registration l l l l l l l l l l l
Microcomputer connection ]6 l l l l l l l l l - l Data operation function l l l l l l l l l l l
MODBUS®/RTU connection l l l l l l l l l - l Offset function l l l l l l l l l l l
MODBUS®/TCP connection l l l l l l l l - - - Security level authentication l l l l l l l l l l l
Temperature controller connection l l l l l l l l l - l (Fingerprint
Inverter connection - Security auth. unit ]6
l l l l l l l l l l function Operator authentication Required CF card/ l l l l l l - - - - -
Servo amplifier connection l l l l l l l l l - l USB memory
CPU direct connection l l l l l l l l l - l <GT16 only>)
CNC MELSECNET/10 connection - - - - -
connection
l l l l l l Lamp display l l l l l l l l l l l
(C6/C64) CC-Link (ID station) connection l l l l l l - - - - - Touch switch l l l l l l l l l l l
Ethernet connection l l l l l l l l - - - Numeric display/input l l l l l l l l l l l
Robot controller connection (CRnD-700) l l l l l l l l - - - Data list display l l l l l l l l l l l
Standard memory capacity 15MB 15MB 15MB 15MB 15MB 15MB 6MB 6MB 3MB 3MB 3MB ASCII display/input l l l l l l l l l l l
Resolution Display colors Memory

Total memory capacity when using Up to Up to Up to Up to Up to Up to Clock display l l l l l l l l l l l


CF card - - - - -
optional memory (standard + optional) 57MB 57MB 57MB 57MB 57MB 57MB Comment display l l l l l l l l l l l
65,536 colors l l l l l l - - - - - Extended alarm monitoring/display (CF card) l l l l l l l l - - -
l l l Alarm list display l l l l l l l l l l l
256 colors - - - - - - l l GT1155- GT1155- GT1155-
QBD only QBDQ/A only HS-QSBD only Alarm history display (CF card) l l l l l l l l l l l

Object settings
l l l Floating alarm display - - - - - - - - l l l
Monochrome (black/white) 16 gray scales - - - - - - - - GT1150- GT1150- GT1150-
QLBD only QLBDQ/A only HS-QLBD only
Parts display (CF card) l l l l l l l l l l l
1024 5 768 dots (XGA) - - - - - - - - - - Parts movement (CF card) l l l l l l l l l l l
l

Screen design
800 5 600 dots (SVGA) - - - - - - - - Panel meter display l l l l l l l l l l l
l l l
640 5 480 dots (VGA) - - - - - - - Level display l l l l l l l l l l l
l l l l
320 5 240 dots (QVGA) - - - - - - - - Trend graph l l l l l l l l l l l
l l l
RS-232 interface Historical trend graph]5 Required]5 (CF card) l l l l l l l l - - -
l l l l l l l l l l l
RS-422 interface - - - - Line graph l l l l l l l l l l l
]3 ]3 ]3 ]3 ]3 ]3 l
Hardware specifications

RS-422/232 interface - - - - - - - - - - Bar graph l l l l l l l l l l l


l
Statistical graph l l l l l l l l l l l
Built-in interface

RS-422/485 interface l l l l l l l l l - -
Bus interface - - - - - - - - - - Scatter graph l l l l l l l l l l l
l
Ethernet interface - - - Status observation function l l l l l l l l l l l
l l l l l l l l
USB host - - - - - Advanced recipe function Required (CF card) l l l l l l - - - - -
USB interface
l l l l l l
USB device Recipe function Required (CF card) l l l l l l l l l l l
l l l l l l l l l l l
CF card interface Time action function l l l l l l l l l l l
l l l l l l l l l l l
Optional function board interface l l l l l l - - - - - Printer unit
Report function Required l l l l l l - - - - -
Extension unit interface CF card
l 2ch l 2ch l 2ch l 2ch l 2ch l 2ch - - - - -
Multimedia & Video/RGB interface - - - - - Hardcopy File saving in CF card CF card l l l l l l l l - - -
l l l l l l
function Printing on printer Required Printer unit l l l l l l - - - - -
Vertical display - - - - - - - - l l -
Clock function (Battery) Barcode function Required l l l l l l l l l l -
l l l l l l l l l l l
Buzzer output RFID function Required l l l l l l l l l l -
l l l l l l l l l l l
Human sensor l l - - - - - - - - - Multimedia unit,
Multimedia function Required l l l l l l - - - - -
CF card
Printer Required Printer unit l l l l l l - - - - -
Others

CF card unit/CF Video/RGB


CF card unit (CF card extension unit) card extension unit l l l l l l - - - - - Remote personal computer function Required l l l l l l - - - - -
input unit
Sound output Required Sound output unit l l l l l l - - - - - Sound output function Required Sound output unit - - - - -
l l l l l l

Others
External input/output Required External input/
output unit l l l l l l - - - - - External input/
External input/output function Required l l l l l l - - - - -
Video input / RGB input / RGB output Required Video/RGB unit - - - - - output unit
l l l l l l
Backlight OFF detection function l l l l l l l l l l l External input/
Operation panel function Required l l l l l l - - - - -
Protective structure output unit
l l l l l l l l l l l
(CF card/ Screen call function l l l l l l l l l l l
Boot OS installation USB memory l l l l l l l l l l l Operation log function Required CF card - - - - -
<GT16 only>) l l l l l l
Start from CF card CF card l l l l l l l l - - - Document display function Required CF card l l l l l l - - - - -
Main unit functions

OS installation l l l l l l l l l l l Logging function Required (CF card) l l l l l l l l - - -


(CF card/
Project data download/upload USB memory l l l l l l l l l l l Project script l l l l l l l l l l l
<GT16 only>) Script function Screen script l l l l l l l l l l l
Resource data upload l l l l l l l l l l l
FA transparent function l l l l l l l l l l l]4 Object script Required l l l l l l - - - - -
Device data transfer function Required l l l l l l - - - - -
Multi-channel function l l l l l l l l - - -
Up to 4ch Up to 4ch Up to 4ch Up to 4ch Up to 4ch Up to 4ch Up to 2ch Up to 2ch System monitor function Required l l l l l l l l l l l
Gateway function Required (CF card) l l l l l l ]7 ]7 - - - l
List editor for A Required l l l l l l l l l GT115- l
Multi-drop connection Coming
soon
Coming
soon
Coming
soon
Coming
soon
Coming
soon
Coming
soon
Coming
soon
Coming
soon
l l l QBDA only
Serial only Serial only Serial only List editor for FX Required l l l l l l l l l - l
Maintenance functions
Modem connection l l l l l l l l l l l SFC monitor function Required CF card l l l l l l - - - - -
Base screen l l l l l l l l l l l Ladder editor function Required CF card l l l l l l - - - - -
Superimposed window display l l l l l l l l l l l Ladder monitor function Required (CF card) l l l l l l - - - - -
Overlap window display l l l l l l l l l l l Intelligent unit monitor function Required l l l l l l - - - - -
Dialog window display l l l l l l l l l l l Q motion monitor function Required l l l l l l - - - - -
BMP image display l l l l l l l l l l l Servo amplifier monitor function Required l l l l l l - - - - -
Supported JPEG image display - - -
image data
l l l l l l l l Network monitor function Required l l l l l l - - - - -
format DXF data l l l l l l l l l l l CNC monitor function Required l l l - l - - - - - -
IGES data l l l l l l l l l l l CNC data input/output function Required (CF card/ l l l - l - - - - - -
USB memory
Standard Japanese, Japanese (supporting European languages), Chinese
Screen design

Specifications

Backup/restoration function Required <GT16 only>) l l l l l l l l - - -


fonts (Simplified), Chinese (Simplified, supporting European l l l l l l l l l l l Maintenance time notification Battery - - - - -
(basic) languages),Chinese (Traditional, supporting European languages) l l l l l l
Chinese (Simplified) Required l l l l l l - - - - - ]1:Functions details, such as the number of settings and the data storage destination, vary depending on the model.
Standard
fonts Chinese (Traditional) Required l l l l l l - - - - - ]2:Required options or optional units other than the optional function board are shown. Parenthesized devices will be required
(optional) depending on conditions of use. For details, see "Notes for use, Selection of optional units and devices" (page 77).
Japanese Required l l l l l l - - - - - Mitsubishi Electric Corporation Nagoya Works is certified to the environment
]3:The RS-232 interface can be used as an RS-422 interface by connecting an RS-422 conversion unit. management system ISO 14001 and the quality management system ISO 9001.
High-quality font l l l l l l l l l l l ]4:Hardware configuration restrictions apply.
TrueType font l l l l l l l l l l l ]5:To use the historical trend graph, it is necessary to set up the logging function in advance. In addition, it is necessary to
TrueType font (7 segments) l l l l l l l l l l l install the optional function OS (logging).
Windows® font ]6:Required only when using fingerprint authentication.
l l l l l l l l l l l
]7:Only the FTP function is supported.
Stroke basic font (extended) Required l l l l l l - - - - -
Stroke font (optional) Required l l l l l l - - - - -
Logo character l l l l l l l l l l l

6 7
General specifications Power supply specifications
Item Specification Specification
Item
Operating ambient Display 0 to 50˚C GT1265/75-VNBA
temperature Other than display 0 to 55˚C Input power supply voltage 100 to 240 V AC (+10%, −15%)
Storage ambient temperature −20˚C to 60˚C Input frequency 50/60Hz ±5%
Operating ambient humidity 10 to 90% RH, no condensation Input maximum voltampere 44 VA (at max. load)
Storage ambient humidity 10 to 90% RH, no condensation Power consumption 18 W or less
Frequency Acceleration Half amplitude Sweep count With backlight off 15 W or less
Conforming to 5 to 9 Hz − 3.5 mm 10 times in each Inrush current 40 A or less (4 ms, at max. load)
Under intermittent
JIS B 3502 of X, Y and Z
Vibration resistance vibration 9 to 150 Hz 9.8 m/s2 −
and directions Permissive instantaneous
Within 20 ms (100 V AC or more)
IEC 61131-2 5 to 9 Hz − 1.75 mm failure time
Under continuous

vibration 9 to 150 Hz 4.9 m/s2 − Noise voltage 1,500 Vp-p, and noise width 1μs, by noise simulator
Noise resistance
Impact resistance Conforming to JIS B 3502 and IEC 61131-2 (147 m/s2, 3 times in each of X, Y and Z directions) with noise frequency 25 to 60 Hz

Operating atmosphere No corrosive gas Withstand voltage 1,500 V AC for 1 minute between power supply terminals and ground
Operating altitude*1 2,000 m or lower 10 MΩ or higher with an insulation resistance tester
Insulation resistance
Installation location In control panel (500 V DC between power supply terminals and ground)

Overvoltage category*2 or lower Applicable wire size 0.75 to 2 [mm2]


Contamination level*3 2 or less Clamp terminal Clamp terminals for M3 screw RAV1.25-3, V2-S3.3, V2-N3A and FV2-N3A
Cooling method Self-cooling Tightening torque
0.5 to 0.8 [N·m]
Grounding Class D grounding (100 Ω or less). Connect to panel if unable to ground. (terminal block’s terminal screws)

*1: Do not operate or store the GOT unit in pressurized environments where the pressure exceeds the 0 m elevation atmospheric
pressure, as this could result in abnormal operation.
*2: Assuming that the device is connected at some point between a public power distribution network and local system equipment.
Category applies to devices that are supplied with power from fixed equipment. The surge withstand voltage is 2,500 V for
devices with ratings up to 300 V.
*3: Index that indicates the level of foreign conductive matter in the operating environment of device. Contamination level 2 denotes
contamination by non-conductive matter only, though momentary conductivity may occur due to occasional condensation.
Do not use or store the GOT under direct sunlight or in an environment with excessively high temperature, dust, humidity or vibration.

Performance specifications
Specification Specification
Item Item
GT1275-VNBA GT1265-VNBA GT1275-VNBA GT1265-VNBA
Type TFT color LCD Battery GT11-50BAT type lithium battery
Screen size 10.4" 8.4" Backed up data Clock data, alarm history, and recipe data
Resolution 640 x 480 [dots] Life Approx. 5 years (operating ambient temperature: 25˚C)
Display size 211.2(W) x 158.4(H) [mm] 170.9(W) x 128.2(H) [mm] RS-232, 1 ch, Transmission speed: 115,200/57,600/38,400/19,200/9,600/4,800 bps,
Number of 16-dot standard font: 40 chars. x 30 lines (2-byte) RS-232 Connector shape: D-sub 9-pin (male), Application: communication with PLC and other FA
devices, communication with personal computer*2
Display*1 displayed characters 12-dot standard font: 53 chars. x 40 lines (2-byte)
Display colors 256 colors RS-422/485, 1 ch, Transmission speed: 115,200/57,600/38,400/19,200/9,600/4,800 bps,
View angle*2 Right/left: 45°, Up/down: 20° RS-422/485 Connector shape: D-sub 9-pin (female),
Application: Communication with PLC and other FA devices
Intensity 200 [cd/m2] Built-in
interface Data transmission system: 100BASE-TX, 1 ch,
Intensity adjustment 4-step adjustment
Ethernet Connector shape: RJ-45 (modular connector),
Life Approx. 52,000 hours (Operating ambient temperature: 25˚C) Application: communication with connected devices
Backlight Cold-cathode fluorescent tube (replaceable), 1 CCFL light. USB (Full Speed 12 Mbps), device 1 ch, Connector shape: Mini-B,
50,000 hours or more 40,000 hours or more USB Application: connection to personal computer
Life*3 (Project data upload/download, OS installation, FA transparent function)
(Time for display intensity reaches 50% at operating ambient temperature of 25˚C)
CF card Compact flash slot 1ch., Connector shape: Type I, Application: data transfer, data storage
Type Analog resistive type
Buzzer output Single tone (tone length adjustable)
Key size Min. 2 x 2 [dots] (per key)
Touch Protective construction JEM1030, Front: IP67f*6
panel No. of simultaneous
Simultaneous touch prohibited*4 (1 point touch only) External dimensions 303(W) x 214(H) x 53(D) 241(W) x 190(H) x 58(D)
touch points
Panel cut dimensions 289(W) x 200(H) mm 227(W) x 176(H) mm
Life 1,000,000 times or more (operating force 0.98 [N] or less)
Weight (excluding mounting brackets) 2.3kg 1.7kg
6 MB built-in flash memory
C drive
(for saving project data and function OS)
Memory*5 Applicable
Screen design
Life (No. of writings) 100,000 times software GT Designer3 Version 1.01B or later*7
software
packages
Built-in SRAM 512KB
*1: On LCD screens, bright dots (permanently lit) and black dots (not to be lit) generally appear. Because the large number of display *4: A n analog resistive touch display is used. When 2 points on the screen are touched simultaneously, if a switch is located the middle
elements exist on an LCD screen, it is not possible to reduce appearance of the bright and black dots to zero. Flickering may occur of the 2 points then the switch will be activated. Therefore, avoid touching 2 points on the screen simultaneously.
depending on the display colors. Note that the existence of bright and black dots is a standard characteristic of LCD screens, and it *5: T he memory is a ROM that permits overwriting of new data without having to delete the existing data.
does not mean that the products are defective or damaged. *6: T his does not guarantee protection in all users’ environments. The unit may not be used in an environment where it is exposed to
*2: LC panels have characteristics of tone reversal. Note that even within the indicated view angles, the screen display may not be clear splashing oil or chemicals for a long time or it is soaked with full of oil mist.
enough depending on the display color. *7: iQ Works will be supported in the next version (except for GT12).
*3: Using the GOT screen save/backlight OFF functions prevents screen burn-in and extends the backlight life.

Component names External dimensions


GT1275 GT1275 GT1265
GT1265

Display, touch panel 303 (11.93)


POWER LED 241 (9.49)
252 (9.92)
(0.39)

175.5 (6.91)
(0.39)
10

10
199 (7.83)

214 (8.43)

190 (7.48)
175 (6.89)

S.MODE
(OS installation switch)

Battery holder CF card interface


Dip switch for setting
(0.39)

CF card access LED


(0.39)

222 (8.74) 175.5 (6.91)


10

10

terminal resistance
(0.24)

(0.24)

CF card access switch


6
6

(inside cover)
51 (2.01)

USB interface
52 (2.05)
53 (2.09)

58 (2.28)

288 (11.34)
226 (8.90)
Ethernet interface Power supply terminal
RS-422/485 interface RS-232 interface Unit : mm (inch)

Product lineup Options


Memory Product name Model Specifications
Model Screen size [Resolution] Display Display color Power supply capacity Battery GT11-50BAT Battery for backup of clock data, alarm history, and recipe data (for replacement)
GT11-70PSCB Protective sheet for 10,4"
GT1275-VNBA 10.4" VGA[640x480 dots] TFT color LCD 256 colors 100 to 240 V AC 6MB Protective sheet Clear, 5 sheets
GT11-60PSCB Protective sheet for 8,4"
GT12
GT12-70VLTN Backlight for GT1275-VNBA
GT1265-VNBA 8.4" VGA[640x480 dots] TFT color LCD 256 colors 100 to 240 V AC 6MB Backlight
GT12-60VLTN Backlight for GT1265-VNBA

+1-847-478-2100 +33-1-55685568 +886-2-2299-2499


+55-11-3146-2202 +48-12-630-47-00 +82-2-3660-9605 When exported from Japan, this manual does
+49-2102-486-0 +420-251-551-470 +65-6470-2480
not require application to the Ministry of
International Trade and Industry for service
+44-1707-278990 +7-812-633-3497 +66-2-517-1328
transaction permission.
+39-39-60531 +27-11-928-2000 +62-21-6330833
+34-93-565-3131 +86-21-2308-2862 +91-124-4630300
+61-2-9684-7777 New publication, effective October 2009
L(NA)08169ENG-A 0910(MDOC) Specifications subject to change without notice.

Das könnte Ihnen auch gefallen