Sie sind auf Seite 1von 46

Marine Cable Catalogue

NORTH EUROPE
Linking the future
As the worldwide leader in the cable industry, For our energy business, we design, produce,
Prysmian Group believes in the effective, efficient distribute and install cables and systems for the
and sustainable supply of energy and information transmission and distribution of power at low,
as a primary driver in the development of medium, high and extra-high voltage.
communities.
For telecoms, the Group is a leading manufacturer
With this in mind, we provide major global of all types of copper and fibre cables, systems and
organisations in many industries with best-in-class accessories for voice, video and data transmission.
cable solutions, based on state-of-the-art
technology. Drawing on over 130 years‘ experience and
continuously investing in R&D, we apply
Through two renowned commercial brands -
excellence, understanding and integrity to
Prysmian and Draka - based in almost 50 countries,
everything we do, meeting and exceeding the
we‘re constantly close to our customers, enabling
needs of our customers across all continents -
them to further develop the world‘s energy and
while at the same time shaping the evolution
telecoms infrastructures and achieve sustainable
of our industry.
and profitable growth.

2
Linking global expertise to the
wheels of industry
On every continent, in applications that range proximity with our customers, delivering products
from air and rail transport infrastructure to heavy and service platforms, built on easy contact,
duty industries such as mining, tunnel drilling and customized solutions and effective supply chains,
defence, Prysmian’s specialist cable solutions sit meeting their specialized requirements, to help
at the heart of significant international projects; them drive the wheels of industry and achieve
supporting the work of major customers, with high- sustainable growth and profitability. As the
performing, durable and safe technology. worldwide leader in the cable industry, Prysmian
Group believes in the effective, efficient and
As the world leader in cabling, we draw on global sustainable supply of energy and information as a
expertise and local presence to work in close primary driver in the development of communities.

3
Marine Cables Insulation Material
Marine cables (ship wiring and ship board cables) XLPE is used as the main insulation material. It
are for installation on board ships. They have been withstands higher temperatures than ordinary
type approved by a classification society and they thermoplastic polyethylene. It is resistant against
have a construction that adheres to standards deformation and various chemicals, with excellent
for marine cables, such as: They are based on mechanical and electrical properties. The maximum
an amount of 7 litres of combustible material conductor temperature stipulated by IEC 60092-
per metre. Bunched cables have to be minimum 360 marine cable standard is 90°C.
3.5 meters tall, when they are in a test chamber
subjected to fire from a burner directed at the Sheathing Material
cables for 40 minutes. The bunched cables may not The sheath is composed of halogen free, flame
burn more than 2.5 meters above the burner. retardant thermoplastic compound. It fulfils the
See figure 2. on page 6. criterion of SHF1 according to IEC 60092-360.
In case of fire the sheathing material offers
Conductor advantages such as reduced emission of smoke
Marine cable conductors are made with stranded and corrosive toxic gasses.
annealed copper, combining flexibility and small
dimensions to provide excellent handling. To Smoke Density
minimise the cable diameter and weight sector Smoke density is tested according to IEC 61034-
shaped conductors are used for bigger cross- 1 (apparatus) and IEC 61034-2 (procedure and
section. requirements). It is done by placing a cable in a
”smoke cube” (3x3x3 m). When the cable is burning,
Fire Resistance the light transmittance is measured using a
These tests are aimed at verifying the behaviour photometric system. 60 % (70 % for a single cable)
of a cable´s circuit integrity during fire. The main visibility is satisfactory if it is attained throughout
three test methods are IEC 60331-21, IEC 60331- the test.
1 and IEC 60331-2, the latter is used for power
and control cables. Marine cable standards require Halogens
a IEC 60331-21 test, where the cable is exposed To test whether a material is halogen free or not,
to a flame at 750°C for 90 minutes followed by a test IEC 60754-1 and 60754-2 are used. The
15 minutes cooling period, while the rated voltage acidity of the gasses from burning materials is
is being applied. No breakdown or short circuit is measured. Halogen-free means that the materials
permitted during the test. See figure 3. on page 6. used in the cable do not contain any halogens –
such as chlorine, bromine, iodine or fluorine. In order
The optional test methods for cables with to attain a self-extinguishing effect that halogens
diameters over 20 mm, is the more rigorous IEC have in cables, ATH (aluminium trihydroxide) based
60331-1 test. For cable diameter not exceeding materials are used instead. This way the negative
20 mm test IEC 60331-2 can also be used, in effects of halogens are avoided.
which a bent cable, affected by mechanical shock,
is subjected to a 830°C flame for minimum
90 minutes.

4
General information

5
Fire Testing Methods Test Methods
Flame retardance of a single cable is tested in IEC 60331-1 & 2 for fire with shock at a
accordance with IEC 60332-1-2. It is performed temperature of at least 830°C. Bunched cables are
on a 60 cm cable sample with a gas flame for 1-8 tested for flame spread.
minutes depending on the cable diameter. The
cable has to be self-extinguishing up to a certain Quality Control
limit to fulfil the test. Flame spread is tested on Each manufactured cable goes through a test
bunched cables in accordance with IEC 60332-3- procedure according to the IEC 60092-300 series
22, which simulating the fire behaviour of cables standards.
installed in a bunch. The main category used is
type A.

6
Explanation of symbols
Conductor temperature Fire resistant
Fire resistant acc. to EN/IEC 60331-1 & 2.
90° Max. conductor temperature °C in continuous
operation.

Screened or armoured Fire retardant


With either copper, aluminum or steel wire, Flame propagation acc. to EN/IEC 60332-1.
foil and tape. Bundled and vertical acc. to EN/IEC 60332-3.

Oil resistant Halogen free


Acc. to DIN EN 60811-404 Halogen free acc. to EN/IEC 60754-1 and
EN/IEC 50267-1.

Weather proof Acidity


Corrosivity acc. to EN/IEC 60754-2.

low Smoke density


Smoke propagation acc. to EN/IEC 61034.

TEMAR type designations


FR = Fire resistant

H F X-
↑ ↑ ↑ ↑
P = Power
(i) = individually screened (AI/PET)
T = Telecommunication
(c) = collectively screened (AI/PET)
A = Armoured
HFX = Halogen-free
U = Unarmoured
Cross-linked C = Copper braid

7
Marine Approvals
As a manufacturer we must be able to prove to our Den Norske Veritas and Germanischer
customers in the maritime industry, that our cables Lloyds
comply with rules and regulations (DNV-GL)
pertaining to the particular type of cable and its Norske Veritas (DNV) founded in Olso,
application purpose on vessels. Norway in 1864 and Germanischer Lloyd (GL)
established in Hamburg Germany in 1867 was
Prysmian Group uses a variety of recogniced and merged in 2013 and today it is a globally leading
accredited third-party organisations to test and quality assurance and risk management
certifify our cables - to ensure the highest lavel of company. DNV- GL offer technical services such as
safety and quality for our customers. design assessment, type approvals, third-party
inspection, verification and testing. Including
certification of materials, components and
systems relevant to the safe operation and
quality of ships and offshore installations.

Bureau Veritas Russian Maritime Register of Shipping


(BV) (RMRS)
Created in 1828, Bureau Veritas is a global leader The classification society Russian Maritime Register
in Testing, Inspection and Certification (TIC), of Shipping (RS) was established in 1913 and
delivering high quality services to help manufactors has been a member of IACS since 1969. Today
meet the growing challenges of quality,
RS is recognized by the European Union and in
safety, environmental protection and social
responsibility. compliance with EC Regulation 391/2009. As well
as certified by QACE. RMRS offers technical design
Bureau Veritas is an accredited EU recognised assessment, surveys and issuing of documents,
organisation allowed to provide EU Mutual certificates and reports to ships and offshore
Recognition Type Approval services according to installations as well as for ship logistics, machinery,
certification, described in rule notes NR 320 and equipment, products and materials.
NR 266.

8
The Italien Naval Register
(RINA)
The Italian Naval Register abbreviated RINA or
RINa was established in Genoa, Italy in June 1861,
Lloyds Register
(LR) and after various changes of denomination and
LR is a leading international provider of tasks assumed the current title in 1938. It is a
classification, compliance and consultancy services private law foundation operating mainly in the
to the marine and offshore industries, helping our classification of ships, confirming that a ship has
clients design, construct and operate their assets to been designed and constructed in compliance
the highest levels of safety and performance. with the regulations and criteria , and is therefore
authorized to activity for which it was conceived.
Manufacturers whose products will be used on
board a vessel classed with Lloyd's Register must
get their products certified to meet the LR Marine &
Offshore Rules.

Classification with Lloyd’s Register means adding


value to our products. This helps merchants
manage their ships and offshore assets to their full
potential, maintain operational effectiveness and
minimise risk to life, property and the environment.
American Bureau of Shipping
(ABS)
The American Bureau of Shipping (ABS) is a
classification society, with a mission to promote
the security of life, property and the natural
environment, primarily through the development
and verification of standards for the design,
construction and operational maintenance of
marine-related facilities.

9
10
PRODUCTS

POWER & CONTROL CABLES MEDIUM VOLTAGE CABLES


UP TO 3 KV UP TO 24 KV

Unarmoured 0.6/1 (1.2) kV Armoured 6/10 (12) kV


TEMAR PHFX-U (LM-HF) . . . . . . . . . . . . . . . . . . . . . . . . . . 12 MV-FHFX/A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Armoured 0.6/1 kV Armoured 12/20 (24) kV


TEMAR PHFX-A (LSM-HF) . . . . . . . . . . . . . . . . . . . . . . . . . 16 MV-FHFX/A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Armoured 1.8/3 (3.6) kV
TEMAR PHFX-A (LSM-HF) . . . . . . . . . . . . . . . . . . . . . . . . . 20
TECHNICAL DATA
General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

INSTRUMENTATION & Laying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41


COMMUNICATION CABLES Rated current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
UP TO 300 V Identification colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Screened 150/250 (300) V Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

TEMAR THFX-U(c) (LJT-HF) . . . . . . . . . . . . . . . . . . . . . . . . 22

Armoured 150/250 (300) V


TEMAR THFX-C (LJST-HF) . . . . . . . . . . . . . . . . . . . . . . . . . 24

Individually screened 250 V


HFX-ISOSA/CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Bus cable 100 V


SIENOPYR-FR PROFIBUS M-02Y(ST)CHX . . . . . . . . . . . . 28

FIRE RESISTANT CABLES


UP TO 1 kV

Unarmoured Power & Control 0.6/1 (1.2) KV


TEMAR PHFX-UFR (LM-FRHF) . . . . . . . . . . . . . . . . . . . . . . 30

Armoured Power & Control 0.6/1 (1.2) kV


TEMAR PHFX-AFR (LSM-FRHF) . . . . . . . . . . . . . . . . . . . . . 32

Armoured 150/250 (300) V


Instrumentation, Communication & Control
SIENOPYR-FR FMHXCH FE 120 . . . . . . . . . . . . . . . . . . . 34

11
POWER & CONTROL MARINE C ABLE

TEMAR PHFX-U
LM-HF

0,6/1 (1,2) kV Conductor


Annealed stranded plain copper, class 2.

UNARMOURED POWER & > Round in single core from 16 to 300


> Round in multicore from 1,5 to 25 mm2
> Sector shaped in multicore from 35 to 240 mm2
CONTROL CABLE > Conductor is compacted when ≥ 25 mm2

For fixed installation in power, lighting and control


Conductor
Fine stranded plain copper, class 5.
circuits on sea vessels and offshore platforms.
> Round in single core from 25 to 300 mm2
> Round in multicore from 35 to 185 mm2

Insulation
Extruded XLPE
> See page 41 for core identification colours

Sheath
Extruded black halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> BV Certificate no. 06580/E0
> RMRS (Russian Maritime Registration of Shipping)

Properties
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-353
Choice and Installation
> Acc. to IEC 60092-352

Temperature
Maximum conductor temperature
> +90°C

Pulling force
Maximum per conductor
> 50 N / mm²

low

90 °

12
Conductor Including Conductor Conductor Cable Cable Bending
Cross-section earth height width diameter weight radius fixed
mm wire mm mm mm kg /km mm

POWER C ABLES
1 x 16 5,0 – 9,0 20 0 75
1 x 25 5,8 – 10,5 30 0 85
1 x 35 6,9 – 11,5 4 05 95
1 x 50 7,9 – 13,0 530 110
1 x 70 9,6 – 15,5 745 130
1 x 95 11,3 – 17,0 10 0 0 14 0
1 x 120 12,7 – 19,0 1260 155
1 x 150 14,1 – 21,0 1550 170
1 x 185 15,7 – 23,5 1910 19 0
1 x 24 0 18,1 – 26,0 249 0 210
1 x 30 0 20, 2 – 29,0 309 0 235
2 x 1,5 1,6 – 8,5 90 35
2 x 2,5 2,0 – 9,5 120 40
2x4 2,6 – 10,5 165 45
2x6 3,1 – 12,0 210 50
3 x 1,5 3G1,5 1,6 – 9,0 105 40
3 x 2,5 3G2,5 2,0 – 10,0 145 40
3x4 3G 4 2,6 – 11,5 205 50
3x6 3G6 3,1 – 12,5 260 50
3 x 10 4,0 – 15,0 430 60
3 x 16 5,0 – 17,5 635 70
3 x 25 5,8 – 20,5 955 85
3 x 35 5,6 9, 2 21,0 1220 170
3 x 50 6,5 10,7 24,0 1610 195
3 x 70 7,9 12,8 28,0 2230 230
3 x 95 9,3 15,1 32,0 3035 260
3 x 120 10,5 17,0 35,0 379 0 280
3 x 150 11,6 18,9 39,0 4 670 320
3 x 185 13,1 21,1 43,5 5810 350
3 x 24 0 15,0 24,4 49,0 7580 395
3 x 30 0 16,8 27, 2 53,5 9 410 430
4 x 1,5 4G1,5 1,6 – 9,8 130 40
4 x 2,5 4G2,5 2,0 – 11,0 180 45
4x4 4G 4 2,6 – 12,5 260 50
4x6 4G6 3,1 – 14,0 350 60
4 x 10 4G10 4,0 – 16,5 545 70
4 x 16 4G16 5,0 – 19,5 820 80
4 x 25 4G25 5,8 – 23,0 124 0 95
4 x 35 4G35 6, 2 8,6 23,5 1610 19 0
4 x 50 4G50 7, 2 9,9 27,5 2120 220
4 x 70 4G70 8,6 12,0 32,0 29 60 260
4 x 95 4G95 10, 2 14,1 36,0 4000 29 0
4 x 120 4G120 11,5 15,8 4 0,0 5010 320
– 5G1,5 1,6 – 11,0 165 45
– 5G2,5 2,0 – 12,0 220 50
– 5G6 3,1 – 15,5 440 65
– 5G10 4,0 – 18,0 660 75
– 5G16 5,0 – 21,0 10 0 0 85
– 5G25 5,8 – 25,5 1530 155

13
Conductor Earth Conductor Conductor Cable Cable Bending
Cross-section wire height width diameter weight radius fixed
mm version mm mm mm kg /km mm

CONTROL C ABLES
7 x 1,5 1,6 – 12,0 20 0 50
12 x 1,5 1,6 – 16,0 330 65
19 x 1,5 1,6 – 18,5 49 0 75
27 x 1,5 1,6 – 22,5 6 80 90
7 x 2,5 2,0 – 13,5 280 55
12 x 2,5 2,0 – 18,0 4 60 75
19 x 2,5 2,0 – 21,0 69 0 85
CL A SS 5 CONDUC TOR (F)
1 x 25 6,5 – 11,5 295 50
1 x 35 7,6 – 12,5 39 0 75
1 x 50 9, 2 – 14,5 550 90
1 x 70 11,0 – 17,0 770 105
1 x 95 13,5 – 19,5 99 0 120
1 x 120 14,9 – 21,5 1250 130
1 x 150 17, 2 – 24,5 1560 150
1 x 185 17,9 – 25,5 1850 160
1 x 24 0 20,6 – 29,0 24 4 0 180
1 x 30 0 24,0 – 33,0 3070 20 0
3 x 35 7,6 – 27,0 1570 170
3 x 50 9, 2 – 31,5 2150 19 0
3 x 70 11,0 – 37,0 30 4 0 230
3 x 95 13,5 – 42,5 3930 260
3 x 120 14,9 – 4 6,5 49 0 0 280
3 x 150 17, 2 – 53,5 619 0 330
3 x 185 17,9 – 56,0 729 0 340
4 x 35 7,6 – 30,5 19 60 19 0
4 x 50 9,14 – 33,0 2430 20 0
4 x 70 11,0 – 41,0 3820 250
4 x 95 13,5 – 4 8,0 50 0 0 29 0
4 x 120 14,9 – 52,5 6260 320
4 x 150 17, 2 – 59,5 78 4 0 360
4 x 185 17,9 – 63,0 924 0 380
– 5G35 7,6 – 32,5 2420 20 0
– 5G50 9, 2 – 39,5 3360 24 0
– 5G70 11,0 – 45,5 4 69 0 280
– 5G95 13,5 – 53,0 614 0 320

14
15
POWER & CONTROL MARINE C ABLE

TEMAR PHFX-A
LSM-HF

0,6/1 (1,2) kV Conductor


Annealed stranded plain copper, class 2.

ARMOURED POWER & > Round in single core from 16 to 300


> Round in multicore from 1,5 to 25 mm2
> Sector shaped in multicore from 35 to 240 mm2
CONTROL CABLE > Conductor is compacted when ≥25 mm2

Conductor
For fixed installation in power, lighting and control Fine stranded plain copper, class 5.
circuits on sea vessels and offshore platforms. > Round in single core from 35 to 300 mm2
> Round in multicore from 35 to 185 mm2

Insulation
Extruded XLPE
> See page 41 for core identification colours

Armour
Braided of copper wires

Sheath
Extruded black halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> BV Certificate no. 07025/E0
> RMRS (Russian Maritime Registration of Shipping)

Properties
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-353
Choice and Installation
> Acc. to IEC 60092-352

Temperature
Maximum conductor temperature
> +90°C

Pulling force
low Maximum per conductor
> 50 N / mm²
90°
16
Conductor Earth Conductor Conductor Diameter Cable Cable Bending
cross-section wire height width over braid diameter weight radius, fixed
mm version mm mm mm mm kg /km mm
POWER C ABLES
1 x 16 5,1 – 7,7 10,5 255 65
1 x 25 5,8 – 9,0 11,5 360 70
1 x 35 6,9 – 10,5 13,0 475 80
1 x 50 7,9 – 11,5 14,5 595 90
1 x 70 9,6 – 14,0 17,0 860 105
1 x 95 11,3 – 16,0 19,0 1135 120
1 x 120 12,7 – 17,5 21,0 14 0 0 130
1 x 150 14,1 – 19,5 23,0 170 0 14 0
1 x 185 15,7 – 21,5 25,0 2095 150
1 x 24 0 18,1 – 24,0 28,0 2650 170
1 x 30 0 20, 2 – 26,5 30,5 3320 185
2 x 1,5 1,6 – 7,5 10,0 130 60
2 x 2,5 2,0 – 8,5 11,0 160 70
2x4 2,6 – 9,5 11,5 20 0 70
2 x6 3,1 10,5 13,0 255 80
3 x 1,5 3G1,5 1,6 – 8,0 10,0 150 60
3 x 2,5 3G2,5 2,0 – 9,0 11,5 195 70
3x4 2,6 – 10,0 13,0 270 80
3x6 3,1 – 11,0 14,0 320 85
3 x 10 4,0 – 13,5 16,5 520 10 0
3 x 16 5,0 – 16,0 19,0 74 0 115
3 x 25 5,8 – 18,5 22,0 1050 135
3 x 35 5,6 9, 2 19,0 23,0 1350 185
3 x 50 6,5 10,7 21,5 25,5 1750 205
3 x 70 7,9 12,8 25,0 29,0 24 0 0 235
3 x 95 9,3 15,1 28,0 33,0 320 0 265
3 x 120 10,5 17,0 31,5 36,5 410 0 295
3 x 150 11,6 18,9 35,0 41,0 50 0 0 330
3 x 185 13,1 21,1 39,5 45,5 6350 365
4 x 1,5 4G1,5 1,6 – 8,5 11,0 180 70
4 x2,5 4G2,5 2,0 – 10,0 12,5 250 75
4x4 4G 4 2,6 – 11,5 14,0 320 85
4x6 4G6 3,1 – 13,0 16,0 450 10 0
4 x 10 4G10 4,0 – 15,5 18,5 670 115
4 x 16 4G16 5,0 – 17,5 21,0 940 130
4 x 25 4G25 5,8 – 20,5 24,0 1350 145
4 x 35 4G35 6, 2 8,6 21,5 25,5 1750 205
4 x 50 4G50 7, 2 9,9 24,5 29,0 230 0 235
4 x 70 4G70 8,6 12,0 28,0 33,0 320 0 265
4 x 95 4G95 10, 2 14,1 32,0 37,0 430 0 30 0
4 x 120 4G120 11,5 15,8 36,0 41,0 530 0 330
5 x 1,5 5G1,5 1,6 – 9,5 12,0 220 75
5 x 2,5 5G2,5 2,0 – 11,0 13,5 29 0 85

17
Conductor Earth Conductor Conductor Diameter Cable Cable Bending
cross-section wire height width over braid diameter weight radius, fixed
mm version mm mm mm mm kg /km mm
CONTROL C ABLES
7 x 1,5 1,6 – 10,5 13,0 270 80
12 x 1,5 1,6 – 14,5 17,0 4 60 105
19 x 1,5 1,6 – 17,0 20,0 640 120
27 x 1,5 1,6 – 21,0 24,5 870 150
7 x 2,5 2,0 – 12,0 14,5 330 90
12 x 2,5 2,0 – 16,5 20,0 620 120
19 x 2,5 2,0 – 19,5 23,0 900 14 0
CL A SS 5 CONDUC TOR (F)
1 x 35 7,6 11,0 14,0 470 85
1 x 50 9,9 – 15,0 17,5 70 0 105
1 x 70 11,0 – 17,0 19,0 920 115
1 x 95 13,5 – 19,0 21,0 1170 125
1 x 120 15, 2 – 21,0 23,5 1450 14 0
1 x 150 17, 2 – 24,0 26,0 1550 155
1 x 185 18,9 – 26,0 28,5 1770 170
1 x 24 0 21,8 – 30,0 32,0 270 0 19 0
3 x 35 7,6 – 25,0 29,0 180 0 180
3 x 50 9, 2 – 29,0 33,0 24 0 0 20 0
3 x 70 11,0 – 3 4,0 38,5 3360 235
3 x 95 13,5 – 4 0,0 45,0 439 0 270
3 x 120 14,9 – 43,5 4 8,5 539 0 295
3 x 150 17, 2 – 50,0 55,5 6760 335
3 x 185 17,9 – 52,5 58,0 7860 350
4 x 35 7,6 – 27,5 31,5 219 0 19 0
4 x 50 9, 2 – 32,0 36,0 2970 220
4 x 70 11,0 – 38,5 43,0 4280 260
4 x 95 13,5 – 4 4,5 50,0 5510 30 0
4 x 120 14,9 – 49,0 54,5 6 850 330
4 x 150 17, 2 – 55,5 61,5 8488 370
4 x 185 17,9 – 58,5 65,0 10 0 4 0 39 0
– 5G35 7,6 – 30,5 3 4,5 269 0 210
– 5G50 9, 2 – 35,5 4 0,0 3660 24 0
– 5G70 11,0 – 42,5 47,5 5210 285
– 5G95 14,5 – 50,0 55,0 6730 330

18
19
POWER & CONTROL MARINE C ABLE

TEMAR PHFX-A
LSM-HF

1,8/3 (3,6) kV Conductor


Annealed stranded plain copper

ARMOURED POWER & > Compacted class 2.


> Fiine stranded class 5.

CONTROL CABLE Insulation


Extruded XLPE
> Plastic coated tape for 3-core cables
For fixed installation on sea vessels and offshore > See page 41 for core identification colours
platforms. Suitable for variable frequency
drives. Armour
Braided of copper wires

Inner sheath
Extruded halogen free polyolefine
> For 3-core cables

Sheath
Extruded red halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approval
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)

Properties
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-353
Choice and Installation
> Acc. to IEC 60092-352

Temperature
Maximum conductor temperature
> +90°C

low

90 °

20
Conductor Conductor Diameter Cable Cable Bending
cross-section diameter over braid diameter weight radius, fixed
mm mm mm mm kg /km mm
TEMAR PHF X-A 3 kV EMC
3 x 50/ 235 7,9 33 37 29 0 0 340
3 x 70/ 35 9,6 37 42 38 4 0 380
3 x 95/ 35 11,3 40 46 4 8 80 420
3 x 120/4 0 12,7 44 50 5920 450
3 x 150/4 0 14,1 47 53 70 0 0 4 80
TEMAR PHF X-A F 3 kV ECM (CL A SS 5.)
3 x 95/ 35 13,5 46 51 510 0 4 60
3 x 120/4 0 15,0 49 55 6170 50 0

21
I N S T R U M E N TAT I O N M A R I N E C A B L E

TEMAR THFX-U(c)
LJT-HF

150/250 (300) V Conductor


Annealed stranded plain copper, class 2.

SCREENED Insulation
Extruded XLPE
INSTRUMENTATION & > See page 41 for core identification colours

TELECOMMUNICATION CABLE Pair


White and blue cores are twisted to pair
> See page 31 for core identification colours
For fixed installation in instrumentation, control and
communication circuits on sea vessels and offshore
Common screen
platforms.
Plastic coated aluminium tape
> Tinned copper drain wire
> Coverage 100 %

Sheath
Extruded grey halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-376 and IEC 60092-350
> Materials
IEC 60228 and IEC 60092-376 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> BV Certificate no. 07027/E0
> RMRS (Russian Maritime Registration of Shipping)

Properties
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-376
Choice and Installation
> Acc. to IEC 60092-352

Temperature
Maximum conductor temperature
> +90°C

low

90 °

22
Conductor Conductor Cable Cable Bending
cross-section diameter diameter weight radius
mm 2 mm mm kg /km mm
1 x 2 x 0,5 0,9 6,5 45 55
2 x 2 x 0,5 (quad) 0,9 7,5 65 60
4 x 2 x 0,5 0,9 11,0 115 90
7 x 2 x 0,5 0,9 12,0 160 10 0
8 x 2 x 0,5 0,9 13,5 180 110
10 x 2 x 0,5 0,9 15,5 220 125
14 x 2 x 0,5 0,9 16,5 285 135
19 x 2 x 0,5 0,9 18,5 360 150
24 x 2 x 0,5 0,9 22,0 50 0 185
1 x 2 x 0,75 1,1 7,0 55 60
2 x 2 x 0,75 (quad) 1,1 8,0 85 70
4 x 2 x 0,75 1,1 12,5 150 10 0
7 x 2 x 0,75 1,1 14,0 225 115
8 x 2 x 0,75 1,1 15,5 260 125
10 x 2 x 0,75 1,1 18,0 315 145
14 x 2 x 0,75 1,1 19,0 4 05 155
19 x 2 x 0,75 1,1 21,5 530 175
24 x 2 x 0,75 1,1 24,5 69 0 20 0

Conductor Conductor Insulation Mutual Loop


cross-section resistance at 20°C resistance capacitance inductance
mm ohm/km ohm/km nF/km (multi-pair) mH/km
ELECTRICAL DATA
n x 2 x0,50 40,4 1030 45 0,7
n x 2 x 0,75 26,0 1020 50 0,7

23
I N S T R U M E N TAT I O N M A R I N E C A B L E

TEMAR THFX-C
LJST-HF

150/250 (300) V Conductor


Annealed stranded plain copper, class 2.

ARMOURED Insulation
Extruded XLPE
INSTRUMENTATION & > See page 31 for core identification colours

TELECOMMUNICATION CABLE Pair


White and blue cores are twisted to pair
> See page 41 for core identification colours
For fixed installation in instrumentation, control and
communication circuits on sea vessels and offshore Armour (Common screen)
platforms. Combined electrical and mechanical protection
> Braid of copper wires
> Drain wire

Sheath
Extruded grey halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-376 and IEC 60092-350
> Materials
IEC 60228 and IEC 60092-376 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> BV Certificate no. 07027/E0
> RMRS (Russian Maritime Registration of Shipping)

Properties
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-376

Temperature
Maximum conductor temperature
> +90°C

low

90 °

24
Conductor Conductor Cable Cable Bending
cross-section diameter diameter weight radius
mm 2 mm mm kg /km mm
1 x 2 x 0,5 0,9 7,5 75 45
2 x 2 x 0,5 (quad) 0,9 8,5 10 0 50
4 x 2 x 0,5 0,9 12,0 19 0 75
7 x 2 x 0,5 0,9 13,0 230 80
8 x 2 x 0,5 0,9 15,0 270 90
10 x 2 x 0,5 0,9 17,0 375 105
14 x 2 x 0,5 0,9 18,0 440 110
19 x 2 x 0,5 0,9 20,0 54 0 120
24 x 2 x 0,5 0,9 24,0 6 80 145
1 x 2 x 0,75 1,1 8,0 85 50
2 x 2 x 0,75 (quad) 1,1 9,0 120 55
4 x 2 x 0,75 1,1 13,0 220 80
7 x 2 x 0,75 1,1 15,5 3 45 95
8 x 2 x 0,75 1,1 16,5 39 0 10 0
10 x 2 x 0,75 1,1 19,0 475 115
14 x 2 x 0,75 1,1 20,5 580 125
19 x 2 x 0,75 1,1 22,5 715 135
24 x 2 x 0,75 1,1 26,0 8 80 160

Conductor Conductor Insulation Mutual Loop


cross-section resistance at 20°C resistance capacitance inductance
mm ohm/km ohm/km nF/km (multi-pair) mH/km
ELECTRICAL DATA
n x 2 x0,50 40,4 1030 45 0,7
n x 2 x 0,75 26,0 1020 50 0,7

25
I N S T R U M E N TAT I O N M A R I N E C A B L E

HFX-ISOSA/Cu
INDIVIDUALLY & COLLECTIVELY SCREENED

250 V Conductor
Annealed stranded plain copper, class 2.

ARMOURED & SCREENED Insulation


Extruded XLPE
INSTRUMENTATION &
Pair
TELECOMMUNICATION CABLE White and blue corse are twisted to pair
> See page 41 for core identification colours

For fixed installation in instrumentation, control and


communication circuits on sea vessels and offshore
Individual screen
Combined electro mechanical protection
platforms.
> Plastic coated aluminium tape
> Tinned copper drain wire

Common screen
Plastic coated aluminium tape
> Tinned copper drain wire, coverage 100 %

Armour
Braid of copper wires

Sheath
Extruded grey halogen free polyolefine, SHF1
> Installation info. and electrical data on page 42-43

Standards
IEC 60092-350 and -376
> Materials
IEC 60228 and IEC 60092-376 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> ABS (American Bureau of Shipping)
> RINA (Italien Naval Register)
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> BV (Bureau Veritas)
> LR - Lloyds Register
> RMRS (Russian Maritime Registration of Shipping)

Properties
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-376
Choice and Installation
> Acc. to IEC 60092-352
low
Temperature
90 °
Maximum conductor temperature
> +90°C
26
Conductor Conductor Conductor Cable Cable Bending
cross-section resistance diameter diameter weight radius
mm 2 ohm/km mm mm kg /km mm
2 x 2 x 0,75 26 1,1 13,6 170 109
4 x 2 x 0,75 26 1,1 17,0 30 0 136
7 x 2 x 0,75 26 1,1 20,1 420 161
10 x 2 x 0,75 26 1,1 24,9 630 199
14 x 2 x 0,75 26 1,1 27,1 760 217
19 x 2 x 0,75 26 1,1 30,1 10 0 0 241
24 x 2 x 0,75 26 1,1 3 4,1 119 0 273

27
I N S T R U M E N TAT I O N M A R I N E C A B L E

SIENOPYR-FR
PROFIBUS Conductor
7 bare copper wires
> E-Cu58 F21 acc. to DIN 40500 part 4
M-02Y(ST)CHX > Cross section 0,35 mm2
> AWG 22 = 0,325 mm2

100 V Insulation
Polyethylene foam (cellular HDPE)
BUS CABLE
Core identification
INSTRUMENTATION CABLE > Aa core: red
> B core: green

For fixed installation in field bus networks on


sea vessels and offshore platforms.
Laying
Laying of the copper cores with two blind cores

Core assembly wrapping


Non-woven plastic textile band

Multi-layer screen
1. Layer: Laminated aluminium foil
2. Layer: Tinned copper wire braid

Inner sheath
Acc. to VDE 0207 part 24
> Halogen free poplymer (HM4)
> Nominal diameter 8 mm

Outer sheath
Acc. to IEC 60092-359
> Halogen free cross-linked polymer
> Black

Approvals
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> LR - Lloyds Register
> BV Certificate no. 07027/E0
> RMRS (Russian Maritime Registration of Shipping)

Properties
Flame Retardance
> Acc. IEC 60332-3-24 (cat C)
Corrosivity
> Acc. to IEC 60754-2
Low Smoke Emission
> Acc. to IEC 61034
Ozone
> Acc. to DIN VDE 0472 part 805, test B
Resistance to chemicals (Test VG 95218 part 2)
> Diesel fuel, oils, hydraulic fluids
> Solvent cleaning agents
> De-ionozed water with 3,5 % NaCI

Temperature
low Maximum conductor temperature
> +80°C
80°
28
Transmission characteristics Other properties

Voltage Temperature
> 100 V > As fixed bus cable
> In installation from –35 to 80˚C
Conductor resisitance
> During installation from –15 to 50˚C
> At 1 km loop at 20˚C
> Conductor temperature in operation ma x. 80˚C
> Ma x. 110 W/km

Tensile load
Characteristic impedance
> During instalaltion: Ma ximum 100 N
> At 3 to 20 MHz 150 ± 15 W
> At 38,4 kHz 185 ± 18,5 W
Bending radius
> At 9,6 kHz 250 ± 25 W
> Single bending minimum 10 x D
> Flexing minimum 20 x D
Wave attenuation
> At 16 MHz ma x. 45 dB/km
Weight
> At 4 MHz ma x. 22 dB/km
> Appr. 110 kg/km
> At 38,4 kHz ma x. 5 dB/km
> At 9,6 kHz ma x. 3 dB/km
Outer diameter
> Ma ximum 9,8 mm
Mutual capacitance
> At 800 Hz
> Ma x. 30 nF/km

Insulation resistance
> At 20˚C
> Minimum 16.000 MWkm

Outer sheath surface resistance


> Minimum 109 W

29
F I R E R E S I S TA N T M A R I N E C A B L E

TEMAR PHFX-UFR
LM-FRHF

0,6/1 (1,2) kV Conductor


Annealed stranded plain copper, class 2.

UNARMOURED, FIRE > Round in multicore from 1,5 to 35 mm2


> Sector shaped in multicore from 50 to 185 mm2
> Conductor is compacted when ≥25 mm2
RESISTANT POWER &
Insulation
CONTROL CABLE Layer of fire resistant mica-tape, with overlap
> Extruded HF 90°C
> See page 41 for core identification colours
For fixed installation in power, lighting and control
circuits on sea vessels and offshore platforms. Sheath
Extruded orange halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> BV Certificate no. 23758/B0
> RMRS (Russian Maritime Registration of Shipping)

Properties
Fire resistant
> Acc. IEC 60331-1 or IEC 60331-2
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-353
Choice and Installation
> Acc. to IEC 60092-352

Temperature
Maximum conductor temperature
> +90°C

Pulling force
Maximum per conductor
> 50 N / mm²

low

90 °

30
Conductor Earth Conductor Conductor Cable Cable Bending
cross-section wire height width diamter weight radius, fixed
mm version mm mm mm kg /km mm

POWER C ABLES
2 x 1,5 1,6 – 10,0 115 40
2 x 2,5 2,0 – 11,0 14 0 45
3 x 1,5 3G1,5 1,6 – 10,5 135 45
3 x 2,5 3G2,5 2,0 – 11,5 170 50
3x4 2,6 – 13,5 265 55
3x6 3,1 – 15,0 340 60
3 x 10 4,0 – 17,0 50 0 70
3 x 16 5,0 – 20,0 725 80
3 x 25 5,8 – 23,0 1130 95
3 x 35 6,8 – 25,5 149 0 155
3 x 50 6,5 10,7 25,5 170 0 205
3 x 70 7,9 12,8 29,5 2360 24 0
3 x 95 9,3 15,1 33,0 3170 270
3 x 120 10,5 17,0 36,0 3950 29 0
3 x 150 11,6 18,9 4 0,0 4840 320
4 x 1,5 4G1,5 1,6 – 11,5 160 45
4 x 2,5 4G2,5 2,0 – 12,5 210 50
4x4 2,6 – 15,0 310 60
4x6 3,1 – 16,3 420 70
4 x10 4,0 – 19,0 630 80
4 x 16 5,0 – 22,0 930 90
4 x 25 5,8 – 25,5 1430 110
4 x 35 6,8 – 28,5 1910 175
4 x 50 7, 2 9,9 29,5 2160 24 0
4 x 70 8,6 12,0 3 4,0 3120 275
4 x 120 11,5 15,8 41,5 5210 335
CONTROL C ABLES
5 x 1,5 1,6 – 12,5 20 0 50
7 x 1,5 1,6 – 14,0 250 60
12 x 1,5 1,6 – 18,0 370 75
19 x 1,5 1,6 – 21,0 550 85
27 x 1,5 1,6 – 26,0 770 160
5 x 2,5 2,0 - 14,0 24 0 55
7 x 2,5 2,0 – 16,0 330 65
12 x 2,5 2,0 – 20,0 520 80
19 x 2,5 2,0 – 24,0 770 150

31
F I R E R E S I S TA N T M A R I N E C A B L E

TEMAR PHFX-AFR
LSM-FRHF

0,6/1 (1,2) kV Conductor


Annealed stranded plain copper, class 2.

ARMOURED, FIRE RESISTANT > Round in multicore from 1,5 to 35 mm2


> Sector shaped in multicore from 50 to 185 mm2
> Conductor is compressed when ≥25 mm2
POWER & CONTROL CABLE
Insulation
Layer of fire resistant mica tape, with overlap
For fixed installation in power, lighting and control > Extruded HF 90°C
circuits on sea vessels and offshore platforms. > See page 41 for core identification colours

Armour
Braid of copper wires
> Designed to act as a collective screen

Sheath
Extruded orange halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-353 and IEC 60092-350
> Materials
IEC 60228 class 2(conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> BV (Bureau Veritas)
> RMRS (Russian Maritime Registration of Shipping)

Properties
Fire resistant
> Acc. IEC 60331-1 or IEC 60331-2
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-353
Choice and Installation
> Acc. to IEC 60092-352

Temperature
Maximum conductor temperature
> +90°C

Pulling force
Maximum per conductor
> 50 N / mm²
low

90 °

32
Conductor Earth Conductor Conductor Diameter Cable Cable Bending
cross-section wire heigth width over braid diameter weight radius, fixed
mm version mm mm mm mm kg /km mm
POWER C ABLES
2x1,5 1,6 – 8,5 11,0 145 70
2x2,5 2,0 – 9,5 12,0 170 75
3x1,5 3G1,5 1,6 – 9,0 11,5 170 70
3x2,5 3G2,5 2,0 – 10,0 12,5 220 75
3x4 2,6 – 13,5 16,0 430 10 0
3x6 3,1 – 15,0 18,0 580 110
3x10 4,0 – 17,0 20,0 780 120
3x16 5,0 – 20,0 23,0 1070 14 0
3x25 5,8 – 25,0 28,5 1630 175
3x35 6,8 – 27,0 30,5 20 60 19 0
3x50 6,5 10,7 27,0 30,5 2250 245
3x70 7,9 12,8 30,5 35,0 30 4 0 280
3x95 9,3 15,1 3 4,0 39,0 4 030 320
3x120 10,5 17,0 37,5 42,5 4920 340
3x150 11,6 18,9 41,0 4 4,5 59 60 360
4x1,5 1,6 – 10,0 12,5 205 75
4x2,5 2,0 – 11,0 13,5 260 85
4x4 2,6 – 15,0 18,0 560 110
4x6 3,1 – 16,5 19,5 69 0 120
4x10 4,0 – 19,0 22,0 940 135
4x16 5,0 – 22,0 25,0 129 0 150
4x25 5,8 – 27,0 31,0 199 0 19 0
4x35 6,8 – 29,5 33,5 254 0 20 0
4x50 7, 2 9,9 30,5 35,0 2930 280
4x70 8,6 12,0 35,0 4 0,0 4 010 320
4x120 11,5 15,8 42,5 4 8,0 6330 385
CONTROL C ABLES
5x1,5 5G1,5 1,6 – 11,0 14,0 250 85
7x1,5 1,6 – 12,0 15,0 320 90
12x1,5 1,6 – 17,0 20,0 570 120
19 x1,5 1,6 – 19,5 23,0 80 0 14 0
27x1,5 1,6 – 24,0 28,0 110 0 170
5x2,5 2,0 – 12,0 15,0 320 90
7x2,5 2,0 – 14,0 16,5 4 60 10 0
12x2,5 2,0 – 19,0 22,0 74 0 130
19 x2,5 2,0 – 22,0 26,0 1050 160

33
FIRE RESISTANT MARINE CABLE

SIENOPYR FR
FMHXCH FE 120
FIRE RESISTANT

150/250 (300) V ARMOURED Conductor


Annealed stranded plain copper, class 2.

INSTRUMENTATION, CONTROL > Round 0,75 mm2

Insulation
& COMMUNICATION CABLE Ceramic HF S95 compound
> White
FIre resistant instrumentation, communication and
control cable for fixed installation on sea vessels Pairs
and offshore platforms. Numbered white cores are twisted to pair
> 2 pair in a quad

Armour
Braid of copper wires

Sheath
Extruded orange halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-376
> Materials
IEC 60228 and IEC 60092-376 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> LR - Lloyds Register
> RMRS (Russian Maritime Registration of Shipping)

Properties
Fire resistant
> Acc. IEC 60331-21 or IEC 60331-31
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-376

Temperature
Maximum conductor temperature
> +90°C

Pulling force
Maximum per conductor
low > 50 N / mm²
90°
34
Conductor Conductor Cable Cabel Bending
cross-section diameter diameter weight radius, fixed
mm mm mm kg/km mm
POWER CABLE
1 x 2 x 0,75 1,1 8,4 92 55

2 x 2 x 0,75 1,1 9,6 127 60

4 x 2 x 0,75 1,1 12,5 200 75

7 x 2 x 0,75 1,1 14,9 305 90

10 x 2 x 0,75 1,1 18,1 430 110

14 x 2 x 0,75 1,1 20,6 560 125

19 x 2 x 0,75 1,1 22,8 700 140

24 x 2 x 0,75 1,1 25,8 870 155

Conductor Conductor Insulation Mutual Loop


cross-section resistance at 20°C resistance capacitance inductance
mm ohm/km ohm/km nF/km mH/km
ELECTRICAL DATA
n x 2 x 0,75 26 480 120 0,7

35
M E D I U M V O LTA G E M A R I N E C A B L E

MV-FHFX/A Conductor
Fine stranded plain copper, class 5.

FLAME RETARDANT Conductor screen


Semi-conductive tape and extruded compound

6/10 (12) kV Insulation


Extruded XLPE nom. thickness 3.4 mm
ARMOURED MEDIUM
Insulation screen
VOLTAGE CABLE Extruded semi-conductive compound

Metallic screen
For fixed installation in power circuits with a rated Copper tape
voltage of 6/10 (12) kV on marine vessels and
offshore platforms.
Inner sheath
Extruded halogen free compound

Armour
Braided of copper wires

Outer sheath
Extruded black halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-354 and IEC 60092-350
> Materials
IEC 60228 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> ABS (American Bureau of Shipping)
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> BV (Bureau Veritas)
> LR - Lloyds Register
> RMRS (Russian Maritime Registration of Shipping)

Properties
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-354
Choice and Installation
> Acc. to IEC 60092-352

Temperature
Maximum conductor temperature
> +90°C

Pulling force
Maximum per conductor
low
> 50 N / mm²
90°
36
Conductor cross Conductor Core Inner covering Braid diameter Outer diameter Cable
section mm 2 diameter diameter thickness mm mm weight
mm mm mm kg /km
1 x150 15,6 25,0 1, 2 29,0 33 2260
3 x 35 7,5 17,0 1, 2 41,0 46 3 4 60
3 x 50 8,7 18,5 1, 2 4 4,5 50 4 010
3 x 70 10,3 20,0 1, 2 47,5 53 4930
3 x 95 12,1 21,5 1, 2 51,0 57 60 60
3 x 120 13,6 23,0 1, 2 54,0 60 7050

Conductor cross Current Conductor Resistance R DC W/km Inductance mH/ Capacitance


section mm 2 rating at +45"C km mF/km
A +20"C +45"C +85"C

1 x 150 369 0.124 0.136 0.156 0.318 0.4 03


3 x 35 10 4 0.524 0.575 0.658 0.357 0.237
3 x 50 130 0.387 0.425 0.4 86 0.3 41 0.26 4
3 x 70 160 0.26 8 0.29 4 0.337 0.321 0.30 0
3 x 95 19 4 0.193 0.212 0.242 0.307 0.3 42
"3 x 120 225 0,153 0.16 8 0.192 0.29 6 0.377
1) IEC 60 092-352 Table B.4 x 0,95 (see also Tables A .1 - A .8)
Other sizes available upon request

37
M E D I U M V O LTA G E M A R I N E C A B L E

MV-FHFX/A Conductor
Fine stranded plain copper, class 5.

FLAME RETARDANT Conductor screen


Semi-conductive tape and extruded compound

12/20 (24) kV Insulation


Extruded XLPE nom. thickness 5,5 mm
ARMOURED MEDIUM
Insulation screen
VOLTAGE CABLE Extruded semi-conductive compound

Metallic screen
For fixed installation in power circuits with a rated Copper tape
voltage of 12/20 (24) kV on marine vessels and
offshore platforms.
Inner sheath
Extruded halogen free compound

Armour
Braided of copper wires

Outer sheath
Extruded black halogen free polyolefine, SHF1
> Installation information and electrical data on
pages 42-43

Standards
IEC 60092-354 and IEC 60092-350
> Materials
IEC 60228 (conductor)
IEC 60092-360 (insulation)
IEC 60092-360 (sheath)

Approvals
> ABS (American Bureau of Shipping)
> DNV-GL (Det Norske Vertitas - Germanischer Lloyd)
> BV (Bureau Veritas)
> LR - Lloyds Register

Properties
Flame Retardance
> Acc. IEC 60332-3-22 (cat A) and IEC 60332-1-2
Halogen Free
> Acc. to IEC 60754-1 and -2
Low Smoke Emission
> Acc. to IEC 61034-1 and -2
Tests
> Acc. to IEC 60092-354
Choice and Installation
> Acc. to IEC 60092-352

Temperature
Maximum conductor temperature
> +90°C

Pulling force
Maximum per conductor
> 50 N / mm²
low

90 °

38
Conductor cross Conductor Core Inner covering Braid diameter Outer diameter Cable
section mm 2 diameter diameter thickness mm mm weight
mm mm mm kg /km
1 x 150 15,6 29,3 1, 2 33,4 38 2670
3 x 35 7,5 21, 2 1, 2 51,3 58 4780
3 x 50 8,7 22,4 1, 2 53,9 60 5450

Conductor cross Current Conductor Resistance R DC W/km Inductance mH/ Capacitance


section mm 2 rating at +45"C km mF/km
A +20"C +45"C +85"C

1 x 150 369 0.124 0.136 0.156 0,366 0, 273


3 x 35 10 4 0.524 0.575 0.658 0,395 0,169
3 x 50 130 0.387 0.425 0.4 86 0,376 0,185
1) IEC 60 092-352 Table B.4 x 0,95 (see also Tables A .1 - A .8)
Other sizes available upon request

39
TECHNICAL
INFORMATION
General
The rated voltage of a cable must not be lower than the Insulation Outer Outer cable Bending
material covering diamter radius
nominal voltage of the circuit in which it is used. The ambient
temperature during operation should be at least 10ºC lower
Unarmoured ≤25 mm 4xD
than the maximum conductor temperature allowed to the
insulation material. Armoured > 25 mm 6xD

Rated Voltage Metal braid


screened Any 6xD
The rated voltages of cables are expressed as
Thermoplastic or armoured
Uo/U(Um) where:
or thermo-
Armoured with
setting
Uo the rated voltage between the conductor and metal wire, tape Any 6xD
with circular
earth, or between the conductor and the metal or sheath
copper
screen for which the cable is designed. conductors
Composite
U the rated voltage between the conductors for polyester or metal
which the cable is designed. laminate screened Any 8xD
units or collective
Um the highest system voltage for which the cables tape screening
may be used
Thermoplastic
or thermo-
setting
Installation Temperature Any Any 8xD
with shaped
The minimum installation temperature for thermoplastic copper
sheathed cables is –15°C. If, however, the cables are warmed conductors
up prior to installation, they can be installed at lower
temperatures. Lowest operation temperature -40°C. Medium Singel-core 12 x D
voltage Any
cables 3-core 9xD
Earthing of Braids
Earthing of braids is to be carried out in accordance with
the regulations of the classification society.

Bending Radius
The minimum bending radii according to IEC 60092-352
in the final fixed assembly:

During installation the recommended radius is 1,5 times


the value given in the table. Maximun pulling tension
P = 50 N/mm2 x total conductor cross section mm2 value
of the cable.

40
TECHNICAL
INFORMATION
Special precautions for single core cables Some other installation examples of single core
for a.c. wiring. cables (phases 1, 2 and 3).

Whenever possible, a.c. wiring should be carried out with


multicore cables. When it is necessary to use single core
cables, they should either be unarmoured or armoured with
a non-magnetic material. Four cables per phase

When several multi or single core cables are connected 1 3 3 1


in parallel per phase, they should be of the same type
and equal length. 2 2 2 2
All cables pertaining to the same phase should be alternated 3 1 1 3
with those of the other phases to avoid unequal division
of the current. In the case of two cables per phase,
for example, the correct dispositions to conform with Or
IEC 60092-352 (phases 1, 2 and 3) are:

1 2 3 3 2 1
3 2 1 1 2 3
1 2 3 3 2 1

Or
Six cables per phase

1 2 3
1 3 3 1 1 3
3 2 1
2 2 2 2 2 2
Or 3 1 1 3 3 1
2 2
1 3 3 1 Or

1 2 3 3 2 1 1 2 3
3 2 1 1 2 3 3 2 1

Ten cables per phase on the same cable tray

3 1 1 3 3 1 1 3 3 1
2 2 2 2 2 2 2 2 2 2
1 3 3 1 1 3 3 1 1 3

41
CURRENT RATING

Current rating for continuous service. Conductor temperature max. +90˚C, ambient max +45˚C. According
to IEC 60092-352, Table B.4 for 0,6/1 kV cables. Up to 6 cables bunched together.

Cores 1 2 3 4 5 7 12 19 27 37

Reduction 1,00 0,85 0,70 0,70 0,58 0,52 0,44 0,37 0,33 0,30

(мм²) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A)
1,5 23 20 16 16 13 12 10 9 8 7
2,5 30 26 21 21 18 16 13 11 10 9
4 41 34 28 28 24
6 52 44 36 36 30
10 72 61 50 50 42
16 96 82 67 67 56
Cross-section

25 127 108 89 89 74
35 157 133 110 110 92
50 196 167 137 137
70 242 206 169 169
95 293 249 205 205
120 339 288 237 237
150 389 331 272 272
185 444 377 311 311
240 522 444 365 365
300 601 511 421 421

Ambient temperature correction factors


According to IEC 60092-352
Тemperature (˚C) 35 40 45 50 55 60 65 70 75
Correction factor 1,10 1,05 1,00 0,94 0,88 0,82 0,74 0,67 0,58

42
IDENTIFICATION COLOURS
POWER & CONTROL CABLE CORES

Cables withour earth cores

Type Neutral (N) Line


2× Blue Brown
3× Brown Black Grey
4× Blue Brown Black Grey
5x - 37× White or black insluation with numbers

Cables with earth cores

Тype Earth (PE) Neutral (N) Line


3G Green - yellow Blue Brown
4G Green - yellow Brown Black Grey
5G Green - yellow Blue Brown Black Grey
7G - 37G White or black insluation with numbers + last core green-yellow

CONTROL & INSTRUMENTATION CABLE CORES


Core a Core b
Pair White insulation + Blue insulation +
black numbers black numbers
1 1 2
2 3 4
N 2*N-1 2*N

43
ELECTRICAL DATA

Cable type Сonductor Resistance acc. to IEC 60228 class 2.


Inductance
TEMAR PHFX Cross-section R (Ω/км)
L
-U, -A, -UFR, -AFR (mm²)
(mн/км)
(n x mm²) at +20˚C at +45˚C at +85˚C
1×35 35 0,524 0,575 0,658 0,316
1×50 50 0,387 0,425 0,486 0,315
1×70 70 0,268 0,294 0,336 0,303
1×95 95 0,193 0,212 0,242 0,292
1×120 120 0,153 0,168 0,192 0,284
1×150 150 0,124 0,136 0,156 0,286
1×185 185 0,0991 0,109 0,124 0,281
1×240 240 0,0754 0,083 0,095 0,276
1×300 300 0,0601 0,066 0,075 0,288
2×1,5 1,5 12,1 13,289 15,191 0,336
2×2,5 2,5 7,41 8,138 9,303 0,313
3×1,5 1,5 12,1 13,289 15,191 0,336
3×2,5 2,5 7,41 8,138 9,303 0,313
3×4 4 4,61 5,063 5,788 0,293
3×6 6 3,08 3,383 3,867 0,281
3×10 10 1,83 2,010 2,297 0,266
3×16 16 1,15 1,263 1,444 0,254
3×25 25 0,727 0,798 0,913 0,211
3×35 35 0,524 0,575 0,658 0,202
3×50 50 0,387 0,425 0,486 0,200
3×70 70 0,268 0,294 0,336 0,197
3×95 95 0,193 0,212 0,242 0,190
3×120 120 0,153 0,168 0,192 0,189
3×150 150 0,124 0,136 0,156 0,191
3×185 185 0,0991 0,109 0,124 0,193
3×240 240 0,0754 0,083 0,095 0,190
3×300 300 0,0601 0,066 0,075 0,188
4×1,5 1,5 12,1 13,289 15,191 0,359
4×2,5 2,5 7,410 8,138 9,303 0,336
4×4 4 4,61 5,063 5,788 0,317
4×6 6 3,08 3,383 3,867 0,304
4×10 10 1,83 2,010 2,297 0,289
4×16 16 1,15 1,263 1,444 0,278
4×25 25 0,727 0,798 0,913 0,267
4×35 35 0,524 0,575 0,658 0,258
4×50 50 0,387 0,425 0,486 0,217
4×70 70 0,268 0,294 0,336 0,213
4×95 95 0,193 0,212 0,242 0,206
4×120 120 0,153 0,168 0,192 0,205
4×150 150 0,124 0,136 0,156 0,209
4×185 185 0,0991 0,109 0,124 0,209
4×240 240 0,0754 0,083 0,095 0,206
4×300 300 0,0601 0,066 0,075 0,204

44
ELECTRICAL DATA

ELECTRICAL DATA
Cable type Reac tance Voltage Drop at +85°C - cos = 0,8 (mV/Am)
TEMAR PHFX
-U, -A, -UFR, -AFR
(n x mm²) at 50 Hz at 6 0 Hz DC 1-phase 50 Hz 3-phase 50 Hz 1-phase 6 0 Hz 3-phase 6 0 Hz

1 x 35 0,0 9 9 0,119 1, 316 1,172 1,015 1,195 1,035


1 x 50 0,0 9 9 0,119 0,972 0, 89 6 0,776 0,920 0,79 6
1 x 70 0,0 95 0,114 0,673 0,653 0,565 0,675 0,585
1 x 95 0,0 92 0,110 0,4 85 0,49 8 0,431 0,520 0,450
1 x 120 0,0 89 0,107 0, 38 4 0,415 0, 359 0,436 0, 378
1 x 150 0,0 9 0 0,10 8 0, 311 0, 357 0, 30 9 0, 379 0, 328
1 x 185 0,0 8 8 0,10 6 0, 249 0, 305 0, 26 4 0, 326 0, 282
1 x 24 0 0,0 87 0,10 4 0,189 0, 255 0, 221 0, 276 0, 239
1 x 30 0 0,0 9 0 0,10 8 0,151 0, 229 0,19 8 0, 251 0, 217
2 x 1,5 0,10 6 0,127 30, 382 24,432 21,159 24,458 21,181
2 x 2,5 0,0 9 8 0,118 18,6 0 6 15,0 03 12,9 93 15,026 13,013
3 x 1,5 0,10 6 0,127 30, 382 24,432 21,159 24,458 21,181
3 x 2,5 0,0 9 8 0,118 18,6 0 6 15,0 03 12,9 93 15,026 13,013
3x4 0,0 92 0,111 11,575 9, 371 8,115 9, 393 8,135
3x6 0,0 8 8 0,10 6 7,73 4 6, 293 5,450 6, 314 5,4 6 8
3 x 10 0,0 83 0,10 0 4,595 3,776 3, 270 3,79 6 3, 28 8
3 x 16 0,0 8 0 0,0 9 6 2, 8 8 8 2,4 0 6 2,0 8 4 2,425 2,10 0
3 x 25 0,0 6 6 0,0 8 0 1, 825 1,5 4 0 1, 33 4 1,556 1, 3 47
3 x 35 0,0 6 4 0,076 1, 316 1,129 0,978 1,14 4 0,9 91
3 x 50 0,0 63 0,075 0,972 0, 853 0,738 0, 8 6 8 0,751
3 x 70 0,0 62 0,074 0,673 0,612 0,530 0,627 0,5 43
3 x 95 0,0 6 0 0,072 0,4 85 0,459 0, 39 8 0,474 0,410
3 x 120 0,059 0,071 0, 38 4 0, 379 0, 328 0, 393 0, 3 4 0
3 x 150 0,0 6 0 0,072 0, 311 0, 321 0, 278 0, 335 0, 291
3 x 185 0,0 61 0,073 0, 249 0, 272 0, 235 0, 28 6 0, 24 8
3 x 24 0 0,0 6 0 0,072 0,189 0, 223 0,193 0, 237 0, 20 6
3 x 30 0 0,059 0,071 0,151 0,192 0,16 6 0, 20 6 0,178
4 x 1,5 0,113 0,136 30, 382 24,4 41 21,167 24,4 6 8 21,19 0
4 x 2,5 0,10 6 0,127 18,6 0 6 15,011 13,0 0 0 15,037 13,022
4x4 0,0 9 9 0,119 11,575 9, 38 0 8,123 9,4 03 8,14 4
4x6 0,0 9 6 0,115 7,73 4 6, 302 5,457 6, 324 5,477
4 x 10 0,0 91 0,10 9 4,595 3,785 3, 278 3, 8 07 3, 297
4 x 16 0,0 87 0,105 2, 8 8 8 2,415 2,0 91 2,436 2,10 9
4 x 25 0,0 8 4 0,101 1, 825 1,561 1, 352 1,581 1, 369
4 x 35 0,0 81 0,0 97 1, 316 1,150 0,9 9 6 1,169 1,013
4 x 50 0,0 6 8 0,0 82 0,972 0, 859 0,74 4 0, 875 0,758
4 x 70 0,0 67 0,0 8 0 0,673 0,619 0,536 0,635 0,550
4 x 95 0,0 65 0,078 0,4 85 0,4 65 0,4 03 0,4 81 0,417
4 x 120 0,0 6 4 0,077 0, 38 4 0, 385 0, 333 0,4 0 0 0, 3 4 6
4 x 150 0,0 6 6 0,079 0, 311 0, 328 0, 28 4 0, 3 43 0, 297
4 x 185 0,0 6 6 0,079 0, 249 0, 278 0, 241 0, 29 4 0, 25 4
4 x 24 0 0,0 65 0,078 0,189 0, 229 0,19 8 0, 245 0, 212
4 x 30 0 0,0 6 4 0,077 0,151 0,19 8 0,171 0, 213 0,18 4

45
Linking the future

Prysmian Group Denmark A/S Prysmian Group Finland Oy Prysmian Group Sweden AB Prysmian Group Norway AS Prysmian Group Estonia AS
Roskildevej 22 Kaapelitie 68 Vallgatan 5 Postboks 369 Bragernes Paldiski mnt. 31
2620 Albertslund 02490 Pikkala 57141 Nässjö 3001 Drammen 76606 Keila
Denmark Sweden Norway Estonia
Johdintie 5
Sales 90620 Oulu Sales Sales Sales
+45 60 39 27 39 +46 38 055 42 09 +47 32 24 90 00 +371 9272 731 (Latvia)
+45 60 39 26 29 Sales +46 38 055 42 08 +370 6 187 4 384 (Lithuania)
+35 010 5661 no-kundesenter@
dk-ti-sales@prysmiangroup.com info.se@prysmiangroup.com prysmiangroup.com info.keila@prysmiangroup.com
fi-info@prysmiangroup.com order.se@prysmiangroup.com
offert.se@prysmiangroup.com

www.prysmiangroup.dk www.prysmiangroup.fi www.draka.se www.prysmiangroup.no www.drakakeila.ee

Das könnte Ihnen auch gefallen