CUBICLE MEDIUM VOLTAGE

SIEMENS Product Range

STANDART STANDART STANDART


Cubicle Ring Main Panel Cubicle Transformer Panel Cubicle Cable PAnel
SF 6 Type R – 24 kV/16kA SF 6 Type T – 24 kV/20kA SF 6 Type K – 24 kV/16kA
Manual Mechanism operation Manual Mechanism operation Manual Mechanism operation
Manual operating mechanism ● Manual operating mechanism ● Manual operating mechanism −
Inerlock for cable compartment ● Inerlock for cable compartment ● Inerlock for cable compartment −
Cable compart cover locked − Cable compart cover locked − Cable compart cover locked ●
C-rails as cable breket ● C-rails as cable breket ● C-rails as cable breket ●
Low voltage niche as terminal ● Low voltage niche as terminal ● Low voltage niche as terminal ●
Release as shunt trip − Release as shunt trip ○ Release as shunt trip −
Mechanical ready for service ● Mechanical ready for service ● Mechanical ready for service −
Signal switch for remote ○ Signal switch for remote ○ Signal switch for remote −
Auxiliary switch for position ○ Auxiliary switch for position ○ Auxiliary switch for position −
Motor operating mechanism ○ Motor operating mechanism ○ Motor operating mechanism −
Lokal remote switch fr motor ○ Lokal remote switch fr motor ○ Lokal remote switch fr motor −
Interlock in circuit breaker − Interlock in circuit breaker − Interlock in circuit breaker −
Spring charge indicator − Spring charge indicator ● Spring charge indicator −
Closing lock out ○ Closing lock out ○ Closing lock out −
De-earthing lock out − De-earthing lock out ○ De-earthing lock out −
Inspection window ○ Inspection window ● Inspection window ○
Low Voltage compartmen cover ○ Low Voltage compartmen cover ○ Low Voltage compartmen cover ○
Locking device three position ○ Locking device three position − Locking device three position −
Short circuit or eart fault ○ Short circuit or eart fault − Short circuit or eart fault ○
Secondary equipment ○ Secondary equipment ○ Secondary equipment ○
Floor Cover ○ Floor Cover − Floor Cover ○
Panel Heating ○ Panel Heating ○ Panel Heating ○

Note: Note: Note:


● Basic equipment ● Basic equipment ● Basic equipment
○ Aditional equipment (option) on request ○ Aditional equipment (option) on request ○ Aditional equipment (option) on request
− Not available − Not available − Not available

Data off switchgear panel Data off switchgear panel Data off switchgear panel
Rated Insulation Level Rated Insulation Level Rated Insulation Level
- Insulated Voltage Ur 24 kV - Insulated Voltage Ur 24 kV - Insulated Voltage Ur 24 kV
- Short Phase 50 kV - Short Phase 50 kV - Short Phase 50 kV
- Lighting impulse 125 kV - Lighting impulse 125 kV - Lighting impulse 125 kV
Rated Current Ir 630 A Rated Current Ir 630 A Rated Current Ir 630 A
- Rated Short time 16 kA - Rated Short time 20 kA - Rated Short time 16 kA
- Rated Peak Current 40 kA - Rated Peak Current 50 kA - Rated Peak Current 40 kA
- Rated Short Circuit 40 kA - Rated Short Circuit 50 kA - Rated Short Circuit 40 kA
- Max Transformer 1600 kVA - Max Transformer 1600 kVA - Max Transformer 1600 kVA
Rate Temperature -5°-55°C Rate Temperature -5°-55°C Rate Temperature -5°-55°C
Rate Frequency 50/60HZ Rate Frequency 50/60HZ Rate Frequency 50/60HZ

SIEMENS SIEMENS SIEMENS


Price : USD 3.610 Price : USD 6.825 Price : USD 2.110
CUBICLE MEDIUM VOLTAGE
SIEMENS
Product Range

REQUEST ORDER REQUEST ORDER REQUEST ORDER


CUBICLE RING MAIN PANEL CUBICLE RING MAIN PANEL CUBICLE RING MAIN PANEL
SF 6 Type R – 24 kV/20kA SF 6 Type R – 24 kV/20kA SF 6 Type R – 24 kV/20kA
Manual Mechanism operation Manual Mechanism operation Manual Mechanism operation
Manual operating mechanism ● Manual operating mechanism ● Manual operating mechanism ●
Inerlock for cable compartment ● Inerlock for cable compartment ● Inerlock for cable compartment ●
Cable compart cover locked − Cable compart cover locked − Cable compart cover locked −
C-rails as cable breket ● C-rails as cable breket ● C-rails as cable breket ●
Low voltage niche as terminal ● Low voltage niche as terminal ● Low voltage niche as terminal ●
Release as shunt trip − Release as shunt trip − Release as shunt trip −
Mechanical ready for service ● Mechanical ready for service ● Mechanical ready for service ●
Signal switch for remote ● Signal switch for remote ● Signal switch for remote ●
Auxiliary switch for position ● Auxiliary switch for position ● Auxiliary switch for position ●
Motor operating mechanism ● Motor operating mechanism ● Motor operating mechanism ○
Lokal remote switch fr motor ○ Lokal remote switch fr motor ● Lokal remote switch fr motor ○
Interlock in circuit breaker − Interlock in circuit breaker − Interlock in circuit breaker −
Spring charge indicator − Spring charge indicator − Spring charge indicator −
Closing lock out ○ Closing lock out ○ Closing lock out ○
De-earthing lock out − De-earthing lock out − De-earthing lock out −
Inspection window ○ Inspection window ○ Inspection window ○
Low Voltage compartmen cover ○ Low Voltage compartmen cover ○ Low Voltage compartmen cover ○
Locking device three position ○ Locking device three position ○ Locking device three position ○
Short circuit or eart fault ○ Short circuit or eart fault ○ Short circuit or eart fault ○
Secondary equipment ○ Secondary equipment ● Secondary equipment ○
Floor Cover ● Floor Cover ● Floor Cover ●
Panel Heating ● Panel Heating ● Panel Heating ●

Note: Note: Note:


● Basic equipment ● Basic equipment ● Basic equipment
○ Aditional equipment (option) on request ○ Aditional equipment (option) on request ○ Aditional equipment (option) on request
− Not available − Not available − Not available

Data off switchgear panel Data off switchgear panel Data off switchgear panel
Rated Insulation Level Rated Insulation Level Rated Insulation Level
- Insulated Voltage Ur 24 kV - Insulated Voltage Ur 24 kV - Insulated Voltage Ur 24 kV
- Short Phase 50 kV - Short Phase 50 kV - Short Phase 50 kV
- Lighting impulse 125 kV - Lighting impulse 125 kV - Lighting impulse 125 kV
Rated Current Ir 630 A Rated Current Ir 630 A Rated Current Ir 630 A
- Rated Short time 20 kA - Rated Short time 20 kA - Rated Short time 25 kA
- Rated Peak Current 50 kA - Rated Peak Current 50 kA - Rated Peak Current 60 kA
- Rated Short Circuit 50 kA - Rated Short Circuit 50 kA - Rated Short Circuit 60 kA
- Max Transformer 1600 kVA - Max Transformer 1600 kVA - Max Transformer 1600 kVA
Rate Temperature -5°-55°C Rate Temperature -5°-55°C Rate Temperature -5°-55°C
Rate Frequency 50/60HZ Rate Frequency 50/60HZ Rate Frequency 50/60HZ

SIEMENS SIEMENS SIEMENS


Price : USD 5.870 Price : USD 9.620 Price : USD 2.780
SIEMENS

Mechanism Motorize Mechanism Motorize


Price : USD 985 Price : USD 1.795

Three Position Switch Disconect Control Panel Selection


Price : USD 1.590 Price : USD 290